BDFB-MIB
Imported Objects
Objects
42 total| Object Name |
|---|
emersonESNA OBJECT IDENTIFIER .1.3.6.1.4.1.885 |
bdfbMIBEmerson Energy Systems North America(ESNA) mini-BDFB MIB. revision 1.0.0.0 MODULE-IDENTITY .1.3.6.1.4.1.885.5 |
bdfbInformation OBJECT IDENTIFIER .1.3.6.1.4.1.885.5.1 |
bdfbMeterPanelVersionNumberMeter Panel Firmware Version Number.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.885.5.1.1 |
bdfbEthernetCardVersionNumberEthernet Card Firmware Version Number.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.885.5.1.2 |
bdfbIdentifierBDFB Identifier String.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.885.5.1.3 |
bdfbStatus OBJECT IDENTIFIER .1.3.6.1.4.1.885.5.2 |
bdfbMeasurement OBJECT IDENTIFIER .1.3.6.1.4.1.885.5.2.1 |
bdfbAverageBusVoltageAverage Bus Voltage.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.885.5.2.1.1 |
bdfbTotalBusCurrentTtotal Bus Current.ro INTEGER .1.3.6.1.4.1.885.5.2.1.2 |
bdfbAlarmAn Alarm Is Active.ro Enumeration .1.3.6.1.4.1.885.5.2.1.3 |
bdfbBusTableBDFB Bus Table. SEQUENCE OF BDFBBusEntry .1.3.6.1.4.1.885.5.2.2 |
bdfbBusEntryBDFB Bus Table Entry. BDFBBusEntry .1.3.6.1.4.1.885.5.2.2.1 |
bdfbBusIndexBDFB Bus Number.ro INTEGER .1.3.6.1.4.1.885.5.2.2.1.1 |
bdfbBusIdentifierBDFB Bus Identifier.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.885.5.2.2.1.2 |
bdfbBusVoltageBDFB Bus Voltage.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.885.5.2.2.1.3 |
bdfbBusCurrentBDFB Bus Current.ro INTEGER .1.3.6.1.4.1.885.5.2.2.1.4 |
bdfbRelayTableBDFB Relay Table. SEQUENCE OF BDFBRelayEntry .1.3.6.1.4.1.885.5.2.3 |
bdfbRelayEntryBDFB Relay Table Entry. BDFBRelayEntry .1.3.6.1.4.1.885.5.2.3.1 |
bdfbRelayIndexBDFB Relay Number.ro INTEGER .1.3.6.1.4.1.885.5.2.3.1.1 |
bdfbRelayIdentifierBDFB Relay Identifier String.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.885.5.2.3.1.2 |
bdfbRelayStatusBDFB Relay Status String.ro Enumeration .1.3.6.1.4.1.885.5.2.3.1.3 |
bdfbTraps OBJECT IDENTIFIER .1.3.6.1.4.1.885.5.3 |
bdfbSystemTraps OBJECT IDENTIFIER .1.3.6.1.4.1.885.5.3.0 |
alarmTrapBDFBRelay1BDFB Relay 1 Typically Configured as Major Remote. NOTIFICATION-TYPE .1.3.6.1.4.1.885.5.3.0.1 |
alarmTrapBDFBRelay2BDFB Relay 2 Typically Configured as Minor Remote. NOTIFICATION-TYPE .1.3.6.1.4.1.885.5.3.0.2 |
alarmTrapBDFBRelay3BDFB Relay 3 Typically Configured as Custom Remote. NOTIFICATION-TYPE .1.3.6.1.4.1.885.5.3.0.3 |
alarmTrapBDFBRelay4BDFB Relay 4 Typically Configured as Custom Remote. NOTIFICATION-TYPE .1.3.6.1.4.1.885.5.3.0.4 |
alarmTrapBDFBAuxABSFuseAuxillary ABS Fuse Trap. NOTIFICATION-TYPE .1.3.6.1.4.1.885.5.3.0.5 |
alarmTrapBDFBCommFailCommunication failure between ethernet card and main board. NOTIFICATION-TYPE .1.3.6.1.4.1.885.5.3.0.6 |
bdfbBusTypeTraps OBJECT IDENTIFIER .1.3.6.1.4.1.885.5.3.1 |
bdfbBusTraps OBJECT IDENTIFIER .1.3.6.1.4.1.885.5.3.1.0 |
trapBusIdentifierBus Identifier. This object cannot be accessed. It is used to clarify the source of a Bus trap DisplayString (SNMPv2-TC) .1.3.6.1.4.1.885.5.3.1.0.2 |
trapBDFBBusFuseBDFB Bus Fuse Alarm. NOTIFICATION-TYPE .1.3.6.1.4.1.885.5.3.1.0.3 |
trapBDFBBusLowVoltageBDFB Bus Low Voltage Alarm. NOTIFICATION-TYPE .1.3.6.1.4.1.885.5.3.1.0.4 |
trapBDFBBusPowerLostBDFB Bus Power Lost Alarm. NOTIFICATION-TYPE .1.3.6.1.4.1.885.5.3.1.0.5 |
trapBDFBBusHighCurrent1BDFB Bus High Current 1 Alarm. NOTIFICATION-TYPE .1.3.6.1.4.1.885.5.3.1.0.6 |
trapBDFBBusHighCurrent2BDFB Bus High Current 2 Alarm. NOTIFICATION-TYPE .1.3.6.1.4.1.885.5.3.1.0.7 |
bdfbGroups OBJECT IDENTIFIER .1.3.6.1.4.1.885.5.4 |
bdfbInformationGroupA collection of objects providing information to identify the BDFB plant and the version of monitoring software. Unknown .1.3.6.1.4.1.885.5.4.1 |
bdfbMeasurementGroupA collection of objects providing BDFB Plant measurements and status. Unknown .1.3.6.1.4.1.885.5.4.2 |
bdfbNotificationsGroupThe notifications which indicate BDFB Plant alarms. Unknown .1.3.6.1.4.1.885.5.4.3 |
More MIBs from Emerson Energy
Browse all Emerson EnergyMIBs →The EES-POWER-FERRO-MIB facilitates SNMP-based monitoring and management of Emerson Energy Systems SMDUH (Single Module Dual Unit Hybrid) ferroresonant power supply units. This module exposes vendor-specific operational metrics, including input/output voltage levels, current status, and internal temperature sensors, to enable real-time fault detection and performance tracking within industrial power infrastructure.
NETSURE-MIB-004-A enables SNMP-based monitoring and management of Emerson Energy Systems (EES) power infrastructure, specifically tracking critical electrical parameters such as voltage, current, power consumption, and device status across power supply units and related energy management hardware.
SNMP MIB module
Standard SNMP MIB module defining data structures for LMS-MIB.
The EES-POWER-MIB module enables SNMP-based monitoring and management of Emerson Energy Systems power distribution units and related electrical infrastructure, specifically exposing metrics for voltage, current, power consumption, frequency, and device status.