BAY-STACK-IPV6-MLD-SNOOPING-MIB
The BAY-STACK-IPV6-MLD-SNOOPING-MIB enables configuration and monitoring of IPv6 Multicast Listener Discovery (MLD) snooping parameters on BayStack switches, specifically managing group membership states, query intervals, and listener aging timers to restrict IPv6 multicast traffic to active ports.
Imported Objects
Objects
71 total| Object Name |
|---|
bayStackIpv6MldSnoopingMib MODULE-IDENTITY .bayStackMibs.44 |
IMPORTS Unknown .bayStackMibs.44 |
bsIpv6MldSnoopingNotifications OBJECT IDENTIFIER .bayStackMibs.44.0 |
bsIpv6MldSnoopingObjects OBJECT IDENTIFIER .bayStackMibs.44.1 |
bsIpv6MldSnoopingInterfaceTable SEQUENCE OF BsIpv6MldSnoopingInterfaceEntry .bayStackMibs.44.1.1 |
bsIpv6MldSnoopingInterfaceEntry BsIpv6MldSnoopingInterfaceEntry .bayStackMibs.44.1.1.1 |
bsIpv6MldSnoopingInterfaceIfIndex InterfaceIndex (IF-MIB) .bayStackMibs.44.1.1.1.1 |
bsIpv6MldSnoopingInterfaceQueryIntervalrw Unsigned32 UNITS "seconds" .bayStackMibs.44.1.1.1.2 |
bsIpv6MldSnoopingInterfaceStatusrw RowStatus (SNMPv2-TC) .bayStackMibs.44.1.1.1.3 |
bsIpv6MldSnoopingInterfaceVersionrw Unsigned32 .bayStackMibs.44.1.1.1.4 |
bsIpv6MldSnoopingInterfaceQuerierro InetAddressIPv6 .bayStackMibs.44.1.1.1.5 |
bsIpv6MldSnoopingInterfaceQueryMaxResponseDelayrw Unsigned32 UNITS "seconds" .bayStackMibs.44.1.1.1.6 |
bsIpv6MldSnoopingInterfaceJoinsro Counter32 .bayStackMibs.44.1.1.1.7 |
bsIpv6MldSnoopingInterfaceGroupsro Gauge32 .bayStackMibs.44.1.1.1.8 |
bsIpv6MldSnoopingInterfaceRobustnessrw Unsigned32 .bayStackMibs.44.1.1.1.9 |
bsIpv6MldSnoopingInterfaceLastListenQueryIntvlrw Unsigned32 UNITS "seconds" .bayStackMibs.44.1.1.1.10 |
bsIpv6MldSnoopingInterfaceProxyIfIndexrw InterfaceIndexOrZero (IF-MIB) .bayStackMibs.44.1.1.1.11 |
bsIpv6MldSnoopingInterfaceQuerierUpTimero TimeTicks (SNMPv2-SMI) .bayStackMibs.44.1.1.1.12 |
bsIpv6MldSnoopingInterfaceQuerierExpiryTimero TimeTicks (SNMPv2-SMI) .bayStackMibs.44.1.1.1.13 |
bsIpv6MldSnoopingInterfaceEnabledrw TruthValue (SNMPv2-TC) .bayStackMibs.44.1.1.1.14 |
bsIpv6MldSnoopingInterfaceIgmpMRouterPortsrw PortSet (RAPID-CITY) .bayStackMibs.44.1.1.1.15 |
bsIpv6MldSnoopingInterfaceIgmpActiveMRouterPortsro PortSet (RAPID-CITY) .bayStackMibs.44.1.1.1.16 |
bsIpv6MldSnoopingInterfaceIgmpMRouterExpirationro Integer32 .bayStackMibs.44.1.1.1.17 |
bsIpv6MldSnoopingInterfaceOperationalVersionro Unsigned32 .bayStackMibs.44.1.1.1.18 |
bsIpv6MldSnoopingInterfaceSendQueryrw TruthValue (SNMPv2-TC) .bayStackMibs.44.1.1.1.19 |
bsIpv6MldSnoopingInterfaceProxyrw TruthValue (SNMPv2-TC) .bayStackMibs.44.1.1.1.20 |
bsIpv6MldSnoopingInterfaceFlushrw Enumeration .bayStackMibs.44.1.1.1.21 |
bsIpv6MldSnoopingInterfaceFlushPortsrw PortSet (RAPID-CITY) .bayStackMibs.44.1.1.1.22 |
bsIpv6MldSnoopingCacheTable SEQUENCE OF BsIpv6MldSnoopingCacheEntry .bayStackMibs.44.1.2 |
bsIpv6MldSnoopingCacheEntry BsIpv6MldSnoopingCacheEntry .bayStackMibs.44.1.2.1 |
bsIpv6MldSnoopingCacheAddress InetAddressIPv6 .bayStackMibs.44.1.2.1.1 |
bsIpv6MldSnoopingCacheIfIndex InterfaceIndex (IF-MIB) .bayStackMibs.44.1.2.1.2 |
bsIpv6MldSnoopingCacheSelfrw TruthValue (SNMPv2-TC) .bayStackMibs.44.1.2.1.3 |
bsIpv6MldSnoopingCacheLastReporterro InetAddressIPv6 .bayStackMibs.44.1.2.1.4 |
bsIpv6MldSnoopingCacheUpTimero TimeTicks (SNMPv2-SMI) .bayStackMibs.44.1.2.1.5 |
bsIpv6MldSnoopingCacheExpiryTimero TimeTicks (SNMPv2-SMI) .bayStackMibs.44.1.2.1.6 |
bsIpv6MldSnoopingCacheStatusrw RowStatus (SNMPv2-TC) .bayStackMibs.44.1.2.1.7 |
bsIpv6MldSnoopingCacheTyperw Enumeration .bayStackMibs.44.1.2.1.8 |
bsIpv6MldSnoopingIgmpGroupTable SEQUENCE OF BsIpv6MldSnoopingIgmpGroupEntry .bayStackMibs.44.1.3 |
bsIpv6MldSnoopingIgmpGroupEntry BsIpv6MldSnoopingIgmpGroupEntry .bayStackMibs.44.1.3.1 |
bsIpv6MldSnoopingIgmpGroupIpv6Address InetAddressIPv6 .bayStackMibs.44.1.3.1.1 |
bsIpv6MldSnoopingIgmpGroupMembers InetAddressIPv6 .bayStackMibs.44.1.3.1.2 |
bsIpv6MldSnoopingIgmpGroupSourceAddress InetAddressIPv6 .bayStackMibs.44.1.3.1.3 |
bsIpv6MldSnoopingIgmpGroupIfIndex InterfaceIndex (IF-MIB) .bayStackMibs.44.1.3.1.4 |
bsIpv6MldSnoopingIgmpGroupInPortro PortList (Q-BRIDGE-MIB) .bayStackMibs.44.1.3.1.5 |
bsIpv6MldSnoopingIgmpGroupExpirationro Integer32 .bayStackMibs.44.1.3.1.6 |
bsIpv6MldSnoopingIgmpGroupUserIdro DisplayString .bayStackMibs.44.1.3.1.7 |
bsIpv6MldSnoopingIgmpGroupTyperw Enumeration .bayStackMibs.44.1.3.1.8 |
bsIpv6MldSnoopingIgmpGroupModero Enumeration .bayStackMibs.44.1.3.1.9 |
bsIpv6MldSnoopingIgmpGroupVersionrw Enumeration .bayStackMibs.44.1.3.1.10 |
bsIpv6MldSnoopingProxyCacheTable SEQUENCE OF BsIpv6MldSnoopingProxyCacheEntry .bayStackMibs.44.1.4 |
bsIpv6MldSnoopingProxyCacheEntry BsIpv6MldSnoopingProxyCacheEntry .bayStackMibs.44.1.4.1 |
bsIpv6MldSnoopingProxyCacheIfIndex InterfaceIndex (IF-MIB) .bayStackMibs.44.1.4.1.1 |
bsIpv6MldSnoopingProxyCacheGroupAddress InetAddressIPv6 .bayStackMibs.44.1.4.1.2 |
bsIpv6MldSnoopingProxyCacheSourceAddress InetAddressIPv6 .bayStackMibs.44.1.4.1.3 |
bsIpv6MldSnoopingProxyCacheVersionro Enumeration .bayStackMibs.44.1.4.1.4 |
bsIpv6MldSnoopingProxyCacheTypero Enumeration .bayStackMibs.44.1.4.1.5 |
bsIpv6MldSnoopingProxyCacheModero Enumeration .bayStackMibs.44.1.4.1.6 |
bsIpv6MldStreamTable SEQUENCE OF BsIpv6MldStreamEntry .bayStackMibs.44.1.5 |
bsIpv6MldStreamEntry BsIpv6MldStreamEntry .bayStackMibs.44.1.5.1 |
bsIpv6MldStreamVlanIfIndex InterfaceIndex (IF-MIB) .bayStackMibs.44.1.5.1.1 |
bsIpv6MldStreamGroupAddress InetAddressIPv6 .bayStackMibs.44.1.5.1.2 |
bsIpv6MldStreamSourceAddress InetAddressIPv6 .bayStackMibs.44.1.5.1.3 |
bsIpv6MldStreamInPortIfIndexro InterfaceIndex (IF-MIB) .bayStackMibs.44.1.5.1.4 |
bsIpv6MldStreamExpirationro TimeTicks (SNMPv2-SMI) .bayStackMibs.44.1.5.1.5 |
bsIpv6MldSnoopingScalars OBJECT IDENTIFIER .bayStackMibs.44.2 |
bsIpv6MldSnoopingFlushrw Enumeration .bayStackMibs.44.2.1 |
bsIpv6MldSnoopingFlushPortsrw PortSet (RAPID-CITY) .bayStackMibs.44.2.2 |
bsIpv6MldSnoopingGroupCountro Unsigned32 .bayStackMibs.44.2.3 |
bsIpv6MldSnoopingStreamCountro Unsigned32 .bayStackMibs.44.2.4 |
bsIpv6MldSnoopingAvailableMulticastEntriesCountro Unsigned32 .bayStackMibs.44.2.5 |
BAY-STACK-IPV6-MLD-SNOOPING-MIB Technical Reference Overview
The BAY-STACK-IPV6-MLD-SNOOPING-MIB SNMP MIB module published by Default defines 71 managed OID objects, including 57 scalar/column metrics, 5 SNMP tables, and 0 trap/notification events anchored at base OID .bayStackMibs.44. Key tabular structures include bsIpv6MldSnoopingInterfaceTable, bsIpv6MldSnoopingCacheTable, bsIpv6MldSnoopingIgmpGroupTable, bsIpv6MldSnoopingProxyCacheTable, bsIpv6MldStreamTable.
Key OID Definitions in BAY-STACK-IPV6-MLD-SNOOPING-MIB
.bayStackMibs.44This MIB module is used for IPv6 MLD Snooping configuration.
.bayStackMibs.44.1.1The (conceptual) table listing IPv6 MLD Snooping interfaces.
.bayStackMibs.44.1.2The (conceptual) table listing the IPv6 multicast groups for which there are members on a particular interface.
.bayStackMibs.44.1.3The (conceptual) table listing IPv6 MLD Snooping IGMP groups.
.bayStackMibs.44.1.4The (conceptual) table listing the IPv6 multicast groups for which the switch is registered in order to receive the multicast traffic.
.bayStackMibs.44.1.5The (conceptual) table listing the IPv6 multicast streams from the network.
.bayStackMibs.44This MIB module is used for IPv6 MLD Snooping configuration.
.bayStackMibs.44.2.1This object is used to remove MLD members from all the interfaces. noAction(1) value is returned at read. all(4) value is used to flush groups and mrouters.
.bayStackMibs.44.2.2The set of ports from all interfaces that are going to be flushed. An empty port set is returned at read.
.bayStackMibs.44.2.3The number of the registered MLD groups
.bayStackMibs.44.2.4The number of the registered IPv6 multicast streams
.bayStackMibs.44.2.5The number of the available multicast entries
.bayStackMibs.44.1.1.1An entry (conceptual row) representing an IPv6 MLD Snooping interface.
.bayStackMibs.44.1.1.1.1The internetwork-layer interface value of the interface for which IPv6 MLD Snooping is enabled.
.bayStackMibs.44.1.1.1.2The frequency at which IPv6 MLD Snooping Host-Query packets are transmitted on this interface.
.bayStackMibs.44.1.1.1.3Row status for create/delete.
.bayStackMibs.44.1.1.1.4The version of IPv6 MLD Snooping which is running on this interface. This object is a place holder to allow for new versions of MLD to be introduced. Version 1 of MLD is defined in RFC 2710.
.bayStackMibs.44.1.1.1.5The address of the IPv6 MLD Snooping Querier on the IPv6 subnet to which this interface is attached.
.bayStackMibs.44.1.1.1.6The maximum query response time advertised in IPv6 MLD Snooping queries on this interface.
.bayStackMibs.44.1.1.1.7The number of times a group membership has been added on this interface; that is, the number of times an entry for this interface has been added to the Cache Table. This object gives an indication of the amount of MLD activity over time.
.bayStackMibs.44.1.1.1.8The current number of entries for this interface in the Cache Table.
.bayStackMibs.44.1.1.1.9The Robustness Variable allows tuning for the expected packet loss on a subnet. If a subnet is expected to be lossy, the Robustness Variable may be increased. IPv6 MLD Snooping is robust to (Robustness Variable-1) packet losses. The discussion of the Robustness Variable is in Section 7.1 of RFC 2710.
.bayStackMibs.44.1.1.1.10The Last Member Query Interval is the Max Response Delay inserted into Group-Specific Queries sent in response to Leave Group messages, and is also the amount of time between Group-Specific Query messages. This value may be tuned to modify the leave latency of the network. A reduced value results in reduced time to detect the loss of the last member of a group.
.bayStackMibs.44.1.1.1.11Some devices implement a form of MLD proxying whereby memberships learned on the interface represented by this row, cause MLD Multicast Listener Reports to be sent on the internetwork-layer interface identified by this object. Such a device would implement mldRouterMIBGroup only on its router interfaces (those interfaces with non-zero mldInterfaceProxyIfIndex). Typically, the value of this object is 0, indicating that no proxying is being done.
More MIBs from Default
Browse all DefaultMIBs →The VMWARE-NSX-MIB enables SNMP-based monitoring and management of VMware NSX-T Data Center virtual network infrastructure, exposing metrics for logical switches, routers, distributed firewalls, and overlay tunnel states. It facilitates the tracking of Layer 2 through Layer 7 service instances, including access control lists, Quality of Service policies, and virtual network topology changes within the software-defined networking environment.