APPIAN-STRATUM-MIB
AI MIB Summary
The APPIAN-STRATUM-MIB enables configuration and status monitoring of Appian Communications Stratum clock hardware, specifically tracking synchronization state, clock source selection, and hardware health metrics for precision timekeeping systems.
Appian Communications Stratum MIB contain the definitions for the configuration and control of Stratum Clock module hardware information and status.
Main OID:
acStratum.1.3.6.1.4.1.2785.2.9
32
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
32 total| Object Name |
|---|
acStratumAppian Communications Stratum MIB contain the definitions for the configuration and control of Stratum Clock module hardware information and status. MODULE-IDENTITY .1.3.6.1.4.1.2785.2.9 |
acStratumTraps OBJECT IDENTIFIER .1.3.6.1.4.1.2785.2.9.0 |
acStratumFailedModuleATrapThe stratum clock module failed. NOTIFICATION-TYPE .1.3.6.1.4.1.2785.2.9.0.1 |
acStratumFailedModuleBTrapThe stratum clock module failed. NOTIFICATION-TYPE .1.3.6.1.4.1.2785.2.9.0.2 |
acStratumClockFailureModuleATrapStratum clock agent has detected a clock timing failure. NOTIFICATION-TYPE .1.3.6.1.4.1.2785.2.9.0.3 |
acStratumClockFailureModuleBTrapStratum clock agent has detected a clock timing failure. NOTIFICATION-TYPE .1.3.6.1.4.1.2785.2.9.0.4 |
acStratumRemovalModuleATrapThe stratum clock module has been removed from the system. NOTIFICATION-TYPE .1.3.6.1.4.1.2785.2.9.0.5 |
acStratumRemovalModuleBTrapThe stratum clock module has been removed from the system. NOTIFICATION-TYPE .1.3.6.1.4.1.2785.2.9.0.6 |
acStratumInsertedModuleATrapA stratum clock module has been inserted into the system. NOTIFICATION-TYPE .1.3.6.1.4.1.2785.2.9.0.7 |
acStratumInsertedModuleBTrapA stratum clock module has been inserted into the system. NOTIFICATION-TYPE .1.3.6.1.4.1.2785.2.9.0.8 |
acStratumClockModuleAOkStratum clock agent has recovered clock timing. NOTIFICATION-TYPE .1.3.6.1.4.1.2785.2.9.0.9 |
acStratumClockModuleBOkStratum clock agent has recovered clock timing. NOTIFICATION-TYPE .1.3.6.1.4.1.2785.2.9.0.10 |
acStratumSystemClockSourceChangeStratum clock source has changed to acStratumCurrentClockSourceSystem. NOTIFICATION-TYPE .1.3.6.1.4.1.2785.2.9.0.11 |
acStratumTableThis table contains two rows for access and control of the Stratum-3 clock modules. SEQUENCE OF AcStratumEntry .1.3.6.1.4.1.2785.2.9.1 |
acStratumEntryA row within the Stratum table containing access control and status information relating to the operation of the Stratum-3 clock module. AcStratumEntry .1.3.6.1.4.1.2785.2.9.1.1 |
acStratumNodeIdThe unique node identification number representing a chassis within a ring of OSAP's.ro AcNodeId (APPIAN-SMI-MIB) .1.3.6.1.4.1.2785.2.9.1.1.1 |
acStratumClockSourceThis attribute determines the clock source.rw Enumeration .1.3.6.1.4.1.2785.2.9.1.1.2 |
acStratumOpStatusModuleAThis field indicates the current operational status for the clock card in slot 16, module A . Only the following values are applicable to the module: operational, offline, initializing, selfTesting, upgrading, standby, shuttingDown, failed, and hw not present.ro AcOpStatus (APPIAN-SMI-MIB) .1.3.6.1.4.1.2785.2.9.1.1.3 |
acStratumOpStatusModuleBThis field indicates the current operational status for the clock card in slot 16, module B . Only the following values are applicable to the module: operational, offline, initializing, selfTesting, upgrading, standby, shuttingDown, failed, and hw not present.ro AcOpStatus (APPIAN-SMI-MIB) .1.3.6.1.4.1.2785.2.9.1.1.4 |
acStratumAlarmStatusModuleAThis attribute contains the current status of the clock alarms. The acStratumAlarmStatus is a bit map represented as a sum. Normal may only be set if and only if no other alarms are set. The various bit positions are: 1 normal No alarm present 2 los Loss of Signal 4 lof Loss of Framero INTEGER .1.3.6.1.4.1.2785.2.9.1.1.5 |
acStratumAlarmStatusModuleBThis attribute contains the current status of the clock alarms. The acStratumAlarmStatus is a bit map represented as a sum. Normal must be set if and oly if no other flash is set. The various bit positions are: 1 normal No alarm present 2 los Loss of Signal 4 lof Loss of Framero INTEGER .1.3.6.1.4.1.2785.2.9.1.1.6 |
acStratumCurrentClockSourceModuleAThis attribute displays the current source that the clock card is selecting.ro Enumeration .1.3.6.1.4.1.2785.2.9.1.1.7 |
acStratumCurrentClockSourceModuleBThis attribute displays the current source that the clock card is selecting.ro Enumeration .1.3.6.1.4.1.2785.2.9.1.1.8 |
acStratumLockoutReferenceThis attribute is a bit mask of clock references that should be locked out from selection for the clock source. None can only be selected when no other lockout references are selected. The various bit positions are: 0 none No clock references are locked out from selection. 1 bits-a BITS source from clock module A is locked out. 2 bits-b BITS source from clock module B is locked out. 4 line-slot1 LINE timing source from SONET slot 1 is locked out. 8 line-slot2 LINE timing source from SONET slot 2 is locked out. 16 holdover-a Holdover from clock module A is locked out. 32 holdover-b Holdover from clock module B is locked out.rw INTEGER .1.3.6.1.4.1.2785.2.9.1.1.9 |
acStratumManualSwitchThis attribute will manually switch the clock references. If the clock reference does not exist, is locked out, or the reference has failed, the switch will not take place.rw Enumeration .1.3.6.1.4.1.2785.2.9.1.1.10 |
acStratumForcedSwitchThis attribute will force switch the clock references. If the clock reference does not exist or is locked out, the switch will not take place.rw Enumeration .1.3.6.1.4.1.2785.2.9.1.1.11 |
acStratumRevertiveRefSwitchEnabledSetting of this attribute to true(1) will the reference to revert back to the original reference when that reference become ready again.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2785.2.9.1.1.12 |
acStratumClearAlarmsSetting of this attribute to true(1) will cause the alarm contacts to clear. Reading this attribute will always return false.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2785.2.9.1.1.13 |
acStratumLineTimingPortSlot1When configured for line timing, this value describes which port on the SONET card will be used to drive the line. This value is not applicable when not configured for line timing.rw INTEGER .1.3.6.1.4.1.2785.2.9.1.1.14 |
acStratumLineTimingPortSlot2When configured for line timing, this value describes which port on the SONET card will be used to drive the line. This value is not applicable when not configured for line timing.rw INTEGER .1.3.6.1.4.1.2785.2.9.1.1.15 |
acStratumBITSFramingTypeWhen configured for BITS timing, this value describes the type of framing that will be used on the BITS interface. This value is not applicable when not configured for BITS timing.rw Enumeration .1.3.6.1.4.1.2785.2.9.1.1.16 |
acStratumCurrentClockSourceSystemThis attribute displays the current clock source that the system is selecting.ro Enumeration .1.3.6.1.4.1.2785.2.9.1.1.17 |