APPIAN-MODULE-MIB
The APPIAN-MODULE-MIB facilitates the monitoring of Appian Communications OSAP hardware modules by exposing real-time status indicators and physical component metrics, such as operational state, temperature, and power supply conditions, via SNMP.
Imported Objects
Objects
33 total| Object Name |
|---|
acModule MODULE-IDENTITY .1.3.6.1.4.1.2785.2.2 |
acModuleTraps OBJECT IDENTIFIER .1.3.6.1.4.1.2785.2.2.0 |
acModuleCfgMismatchTrap NOTIFICATION-TYPE .1.3.6.1.4.1.2785.2.2.0.1 |
acModuleResetFailedTrap NOTIFICATION-TYPE .1.3.6.1.4.1.2785.2.2.0.2 |
acModuleSwVersionTrap NOTIFICATION-TYPE .1.3.6.1.4.1.2785.2.2.0.3 |
acModuleRemovalTrap NOTIFICATION-TYPE .1.3.6.1.4.1.2785.2.2.0.4 |
acModuleInsertedTrap NOTIFICATION-TYPE .1.3.6.1.4.1.2785.2.2.0.5 |
acModuleFailureTrap NOTIFICATION-TYPE .1.3.6.1.4.1.2785.2.2.0.6 |
acModuleTable SEQUENCE OF AcModuleEntry .1.3.6.1.4.1.2785.2.2.1 |
acModuleEntry AcModuleEntry .1.3.6.1.4.1.2785.2.2.1.1 |
acModuleNodeIdro AcNodeId (APPIAN-SMI-MIB) .1.3.6.1.4.1.2785.2.2.1.1.1 |
acModuleSlotro AcSlotNumber (APPIAN-SMI-MIB) .1.3.6.1.4.1.2785.2.2.1.1.2 |
acModuleNumberro AcModuleNumber .1.3.6.1.4.1.2785.2.2.1.1.3 |
acModuleAdminStatusrw AcAdminStatus (APPIAN-SMI-MIB) .1.3.6.1.4.1.2785.2.2.1.1.4 |
acModuleCfgTyperw AcModuleType .1.3.6.1.4.1.2785.2.2.1.1.5 |
acModuleTypero AcModuleType .1.3.6.1.4.1.2785.2.2.1.1.6 |
acModuleOpStatusro AcOpStatus (APPIAN-SMI-MIB) .1.3.6.1.4.1.2785.2.2.1.1.7 |
acModuleRevisionro INTEGER .1.3.6.1.4.1.2785.2.2.1.1.8 |
acModuleSerialNumberro DisplayString .1.3.6.1.4.1.2785.2.2.1.1.9 |
acModuleProductionDatero DisplayString .1.3.6.1.4.1.2785.2.2.1.1.10 |
acModuleFirmwareNamero DisplayString .1.3.6.1.4.1.2785.2.2.1.1.11 |
acModuleFirmwareRevisionro INTEGER .1.3.6.1.4.1.2785.2.2.1.1.12 |
acModuleNumberFailuresro Counter32 .1.3.6.1.4.1.2785.2.2.1.1.13 |
acModuleResetrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2785.2.2.1.1.14 |
acModuleNumberPortsro INTEGER .1.3.6.1.4.1.2785.2.2.1.1.15 |
acModuleNamero DisplayString .1.3.6.1.4.1.2785.2.2.1.1.16 |
acModuleSwVersionro AcSwVersion (APPIAN-SMI-MIB) .1.3.6.1.4.1.2785.2.2.1.1.17 |
acModuleDiagTestModerw Enumeration .1.3.6.1.4.1.2785.2.2.1.1.18 |
acModuleDiagStatusro INTEGER .1.3.6.1.4.1.2785.2.2.1.1.19 |
acModuleDiagResultStringro DisplayString .1.3.6.1.4.1.2785.2.2.1.1.20 |
acModuleActiveSlotro AcMediaSlotNumber .1.3.6.1.4.1.2785.2.2.1.1.21 |
acModulePrimarySlotro AcMediaSlotNumber .1.3.6.1.4.1.2785.2.2.1.1.22 |
acModuleBackupSlotro AcMediaSlotNumber .1.3.6.1.4.1.2785.2.2.1.1.23 |
APPIAN-MODULE-MIB Technical Reference Overview
The APPIAN-MODULE-MIB SNMP MIB module published by Appian defines 33 managed OID objects, including 23 scalar/column metrics, 1 SNMP tables, and 6 trap/notification events anchored at base OID .1.3.6.1.4.1.2785.2.2. Key tabular structures include acModuleTable. Monitored SNMP traps/notifications include acModuleCfgMismatchTrap, acModuleFailureTrap, acModuleInsertedTrap, acModuleRemovalTrap, acModuleResetFailedTrap, acModuleSwVersionTrap.
Key OID Definitions in APPIAN-MODULE-MIB
.1.3.6.1.4.1.2785.2.2Appian Communications OSAP Modules MIB contain the definitions for module hardware information and status.
.1.3.6.1.4.1.2785.2.2.1A table containing the module information for each module within the chassis. This table is automatically created during system initialization and updated when modules are removed and inserted. When a module is removed, the row is automatically removed.
.1.3.6.1.4.1.2785.2.2.0.1The configured module type does not match with the actual module present.
.1.3.6.1.4.1.2785.2.2.0.6The module in this slot did not pass diagnostics or has been marked as a failed board by operational software.
.1.3.6.1.4.1.2785.2.2.0.5A module has been inserted into this chassis.
.1.3.6.1.4.1.2785.2.2.0.4A module has been removed from this chassis.
.1.3.6.1.4.1.2785.2.2.0.2The module couldn't be reset.
.1.3.6.1.4.1.2785.2.2.0.3Two different version of software are currently running within the same chassis. This is an unsupported operational mode.
.1.3.6.1.4.1.2785.2.2.1.1.21The slot number within the chassis where the media module that is driving this module resides. This attribute is set to 0 for rows in which the module is either not an IO card or is an IO card that has no appropriate media card present in the chassis.
.1.3.6.1.4.1.2785.2.2.1.1.4The administrative status. See AcAdminStatus for the semantics.
.1.3.6.1.4.1.2785.2.2.1.1.23The slot number within the chassis where the backup media module that could drive this module resides. This attribute is set to 0 for rows in which the module is either not an IO card or is an IO card that has no appropriate media card present in the chassis.
.1.3.6.1.4.1.2785.2.2.1.1.5The acModuleCfgType field enumeration is used to uniquely identify the module type which is currently in a slot within the chassis, as defined by the AppianVista EMS.
.1.3.6.1.4.1.2785.2.2.1.1.20The results of the diagnostic test returned as a printable ASCII string. Refer to the diagnostics utility guide for details.
.1.3.6.1.4.1.2785.2.2.1.1.19The unique results code as returned from the test mode issued via acModuleDiagTestMode. Refer to the diagnostic utility guide for details.
.1.3.6.1.4.1.2785.2.2.1.1.18The diagnostics test mode allows the user to select a basic(1), advanced(2) or stress(3) series of powerup self tests to be run when the acModuleOpStatus field is changed to selfTesting(4). A basic(1) test performs a quick self test and is the mode which is by default selected at powerup. Advanced(2) mode is used to run a more thorough series of tests and stress(3) mode is used to execute a system test packet loopback type of powerup test. In all test modes, the acModuleDiagStatus field contains a unique results code (Refer to diagnostics utility guide). The results of a test request is also written as a string to the acModuleDiagResultString field.
.1.3.6.1.4.1.2785.2.2.1.1Module information record containing hardware, software, firmware, name data for a specific node.slot within a chassis. Row's in this table are automatically instantiated at system initialization.
.1.3.6.1.4.1.2785.2.2.1.1.11This string contains the name of the firmware file resident on the switch controller file system. Note: Not all modules contain firmware.
.1.3.6.1.4.1.2785.2.2.1.1.12The revision of the firmware.
.1.3.6.1.4.1.2785.2.2.1.1.16The official human readable name for the type of module indicated by acModuleType.
.1.3.6.1.4.1.2785.2.2.1.1.1The unique node identification number representing a chassis within a ring of OSAP's.
.1.3.6.1.4.1.2785.2.2.1.1.3The module number within the slot where this module resides.
.1.3.6.1.4.1.2785.2.2.1.1.13The total number of failure events reported by the module.
.1.3.6.1.4.1.2785.2.2.1.1.15A count of the total number of ports located on this module. Not all modules contain user configurable or usable ports.
.1.3.6.1.4.1.2785.2.2.1.1.7This field indicates the current operational status for the module. Only the following values are applicable to the module: operational, offline, initializing, selfTesting, upgrading, standby, shuttingDown and failed.
More MIBs from Appian
Browse all AppianMIBs →The APPIAN-PPORT-SONET-MIB enables monitoring and management of SONET/SDH physical layer interfaces on Appian hardware, specifically tracking performance metrics such as signal quality, error counts (SEF, SES), and port status states.
The APPIAN-PPORT-DS1-MIB module provides granular monitoring and management of Appian DS1 interface parameters, specifically tracking physical layer statistics and interface states for T1 circuits. This module enforces strict isolation by maintaining separate management tables for each OSAP, ensuring that DS1 interface data is not shared across different operational contexts.
The APPIAN-PPORT-SONET-TRAP-MIB module defines SNMP trap notifications for Appliance P-Port SONET/SDH interfaces to alert network operations of critical physical layer events, including signal loss, framing errors, and alarm conditions. These traps enable automated fault detection and immediate response to SONET/SDH link degradation or failure without requiring active polling of interface status counters.
The APPIAN-LPORT-DS1-MIB module enables monitoring and management of Appian logical DS1 interface states, traffic counters, and error statistics for T1 digital signal level 1 circuits. It provides specific OID access to interface status, packet throughput, and fault conditions for Appian network devices supporting DS1 aggregation.
The APPIAN-SYSTEM-MIB module enables configuration and monitoring of Appian Communications Services system components, specifically managing Configuration Management, Event Logging, Statistics Collection, Alarms, Thresholds, and OSAP discovery topology protocols. It provides granular control over system-level operational metrics and alarm states for Appian's communication infrastructure.
The APPIAN-PPORT-DS3-MIB enables monitoring and management of DS3 interface statistics, status, and configuration parameters on Appian Communications OSAP2k platforms. This module provides vendor-specific tables for tracking DS3 physical layer metrics, such as line coding, framing, and error counts, which are isolated to individual OSAP instances rather than shared across the system.