Home/Catalog/A3COM51-SS9000SX

A3COM51-SS9000SX

AI MIB Summary

Standard SNMP MIB module defining data structures for A3COM51-SS9000SX.

29
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

29 total
Object Name
a3Com
OBJECT IDENTIFIER
.1.3.6.1.4.1.43
products
OBJECT IDENTIFIER
.1.3.6.1.4.1.43.1
hub
OBJECT IDENTIFIER
.1.3.6.1.4.1.43.1.8
superStackSwitch9000SX
OBJECT IDENTIFIER
.1.3.6.1.4.1.43.1.8.32
superStackSwitch3800
OBJECT IDENTIFIER
.1.3.6.1.4.1.43.1.8.34
superStackSwitch9100
OBJECT IDENTIFIER
.1.3.6.1.4.1.43.1.8.36
superStackSwitch9000SX-mib
OBJECT IDENTIFIER
.1.3.6.1.4.1.43.27
ss9000UnitPaceModeThis object specifies the type of backoff algorithm. Any port can use the standard ethernet algorithm or, for PACE applications, it can be set into low latency mode. In this mode, the backoff algorithm is optimized to minimize the possibility of collisions. PACE mode can be set for the whole unit only.rw
Enumeration
.1.3.6.1.4.1.43.27.1
ss9000PortTableThe port management table.
SEQUENCE OF Ss9000PortTableEntry
.1.3.6.1.4.1.43.27.2
ss9000PortTableEntryThis table contains pairs of 32-bit counters which map to RMON 2 64-bit counters
Ss9000PortTableEntry
.1.3.6.1.4.1.43.27.2.1
ss9000PortIndexThe index of this table entry.ro
INTEGER
.1.3.6.1.4.1.43.27.2.1.1
ss9000PortRxPktCtLowThe lower 32 bits of the 64 bit receive packet counter for this portro
Counter
.1.3.6.1.4.1.43.27.2.1.2
ss9000PortRxPktCtHighThe upper 32 bits of the 64 bit receive packet counter for this portro
Counter
.1.3.6.1.4.1.43.27.2.1.3
ss9000PortRxByteCtLowThe lower 32 bits of the 64 bit receive byte counter for this portro
Counter
.1.3.6.1.4.1.43.27.2.1.4
ss9000PortRxByteCtHighThe upper 32 bits of the 64 bit receive byte counter for this portro
Counter
.1.3.6.1.4.1.43.27.2.1.5
ss9000PortTxPktCtLowThe lower 32 bits of the 64 bit transmit packet counter for this portro
Counter
.1.3.6.1.4.1.43.27.2.1.6
ss9000PortTxPktCtHighThe upper 32 bits of the 64 bit transmit packet counter for this portro
Counter
.1.3.6.1.4.1.43.27.2.1.7
ss9000PortTxByteCtLowThe lower 32 bits of the 64 bit transmit byte counter for this portro
Counter
.1.3.6.1.4.1.43.27.2.1.8
ss9000PortTxByteCtHighThe upper 32 bits of the 64 bit transmit byte counter for this portro
Counter
.1.3.6.1.4.1.43.27.2.1.9
ss9000SaveConfigurationWhen this object is set, the device will copy the contents of the configuration database to a buffer and save it to the persistant store specified by the value of the object. The save is performed asynchronously, and the snmp agent will continue to respond to both gets and sets while the save is taking place. A network management application may use the ss9000SaveStatus object to determine when the asynchronous save operation has completed.rw
Enumeration
.1.3.6.1.4.1.43.27.3
ss9000SaveStatusThis object will return the status of a save operation invoked by setting the ss9000SaveConfiguration object. A network management application can read this object to determine that a save operation has completed.ro
Enumeration
.1.3.6.1.4.1.43.27.4
ss9000MauType
OBJECT IDENTIFIER
.1.3.6.1.4.1.43.27.5
ss9000MauType1000BaseSX
OBJECT IDENTIFIER
.1.3.6.1.4.1.43.27.5.1
extreme
OBJECT IDENTIFIER
.1.3.6.1.4.1.1916
RFC-1215
Unknown
.1.3.6.1.4.1.1916
overheatA overheat trap indicates that the on board tempature sensor has reported a overheat condition. System will shutdown until unit has suficiently cooled such that operation may begin again. A cold start trap will be issued when the unit has come back on line.
TRAP-TYPE
.1.3.6.1.4.1.1916.0.1
fanfailedA fan failed trap indicates one or more of the cooling fans inside the device has failed. A fanOK trap will be sent once the fan has attained normal operation.
TRAP-TYPE
.1.3.6.1.4.1.1916.0.2
fanOKA fan has tansitioned out of a failure state and is now operating correctly.
TRAP-TYPE
.1.3.6.1.4.1.1916.0.3
invalidLoginAttemptA user attempted to login to console or by telnet but was refused access due to incorrect username or password
TRAP-TYPE
.1.3.6.1.4.1.1916.0.4