The ZHONE-SECHTOR100-MIB provides SNMP-based monitoring and management capabilities for Zhone Sechtor 100 DSL Access Multiplexer (DSLAM) hardware, exposing device-specific operational metrics such as port status, line statistics, and hardware health indicators. This module enables network administrators to track performance data and fault conditions specific to the Sechtor 100 platform's DSL aggregation functions.

MIB module for elements specific to Sechtor 100 products.
Main OID:
zhoneSechtor100.1.3.6.1.4.1.5504.6.19
31
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

31 total
Object Name
sechtor100EnvironmentAll the scalar objects under sechor100Environment are deprecated and replaced by their respective objects indexed by zhoneShelfIndex and zhoneSlotIndex.deprecated
OBJECT IDENTIFIER
.1.3.6.1.4.1.5504.2.4.1.1
s100FanOperationalStatusThis variable describes the working status of the four fans for the Sechtor 100. If any one of the four fans is not running correctly, this variable shows 'fanFailure'. When all the fans are working, the value of this variable is 'operational'.rodeprecated
Enumeration
.1.3.6.1.4.1.5504.2.4.1.1.1
s100ThermoAUpperThresholdThis variable specifies the upper threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is above this value, s100ThermoAOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 65 degrees Celsius.rwdeprecated
Integer32
.1.3.6.1.4.1.5504.2.4.1.1.2
s100ThermoBUpperThresholdThis variable specifies the upper threshold for thermometer B in degrees Celsius. When s100ThermoBTemperature is above this value, s100ThermoBOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 60 degrees Celsius.rwdeprecated
Integer32
.1.3.6.1.4.1.5504.2.4.1.1.3
s10ThermoALowerThresholdThis variable specifies the lower threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoAOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius.rwdeprecated
Integer32 (-10..5)
.1.3.6.1.4.1.5504.2.4.1.1.4
s100ThermoBLowerThresholdThis variable specifies the lower threshold for thermometer B in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoBOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius.rwdeprecated
Integer32 (-10..5)
.1.3.6.1.4.1.5504.2.4.1.1.5
s100ThermoATemperatureThe temperature in degrees Celsius read by the IC thermometer sensor A on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer A is located. The valid temperature range for the thermometer is -55..125 degrees Celsius.rodeprecated
Integer32 (-55..125)
.1.3.6.1.4.1.5504.2.4.1.1.6
s100ThermoBTemperatureThe temperature in degrees Celsius read by the IC thermometer sensor B on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer B is located. The valid temperature range for the thermometer is -55..125 degrees Celsius.rodeprecated
Integer32 (-55..125)
.1.3.6.1.4.1.5504.2.4.1.1.7
s100ThermoAOperationalStatusThe operational status indicator for thermometer A. Valid values are: * withinOperationalRange - s100ThermoATemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoATemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoATemperature is lower than its lower threshold.rodeprecated
Enumeration
.1.3.6.1.4.1.5504.2.4.1.1.8
s100ThermoBOperationalStatusThe operational status indicator for thermometer B. Valid values are: * withinOperationalRange - s100ThermoBTemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoBTemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoBTemperature is lower than its lower threshold.rodeprecated
Enumeration
.1.3.6.1.4.1.5504.2.4.1.1.9
sechtor100TrapsAll Sechtor 100 MIB traps are defined under sechtor100Traps.
OBJECT IDENTIFIER
.1.3.6.1.4.1.5504.2.4.1.2
sechtor100TrapsPrefixPrefix 0 for Sechtor 100 MIB traps as required by SNMPv2.
OBJECT IDENTIFIER
.1.3.6.1.4.1.5504.2.4.1.2.0
s100FanStatusChangeThis trap is generated whenever the value of s100FanOperationalStatus changes. This trap is deprecated and is replaced by sechtor100FanStatusChange.deprecated
NOTIFICATION-TYPE
.1.3.6.1.4.1.5504.2.4.1.2.0.1
s100ThermoStatusChangeThis trap is generated whenever sechtor100ThermoAOperationalStatus or sechtor100ThermoBOperationalStatus changes its value. This trap is deprecated and is replaced by sechtor100ThermoStatusChange.deprecated
NOTIFICATION-TYPE
.1.3.6.1.4.1.5504.2.4.1.2.0.2
sechtor100FanStatusChangeThis trap is generated whenever the value of sechtor100FanOperationalStatus changes. The Sechtor 100 is identified by the shelf and slot number from instance OID's contained in the trap VarBind objects.
NOTIFICATION-TYPE
.1.3.6.1.4.1.5504.2.4.1.2.0.3
sechtor100ThermoStatusChangeThis trap is generated whenever sechtor100ThermoAOperationalStatus or sechtor100ThermoBOperationalStatus changes its value. The Sechtor 100 is identified by the shelf and slot number from instance OID's contained in the trap VarBind objects.
NOTIFICATION-TYPE
.1.3.6.1.4.1.5504.2.4.1.2.0.4
sechtor100ConfigTableThis table contains redundancy variables and environmental variables for monitoring fans and thermometers. For redundancy, the peer MAC address is maintained in this table. Also, one variable specifies whether redundancy is enabled or not. There are two thermometers on the Sechtor 100 board. In this MIB, thermometers 'A' and 'B' are used to differentiate these two thermometers: Thermometer A - the thermometer located near the 750 processor. It is expected that this thermometer have a higher temperature reading than thermometer B because of the heat generated by the processor. It is recommended that a higher upper threshold is set for this thermometer. Thermometer B - the thermometer located near the outlet on the right side of the Sechtor 100 board. The profile for this table will be auto-created as 1/1 with the sechtor100RedundancyEnable variable set to FALSE. This profile should not be deleted except for the following two cases: 1) When a unit operating in simplex mode is intended to be used in duplex mode as the slot 2 of the redundant system. The user needs to create a 1/2 profile. 2) The unit configured as slot 2 of a redundant system is intended to be used in simplex mode. Then the 1/2 profile should be deleted and replaced with a 1/1 profile.
SEQUENCE OF Sechtor100ConfigEntry
.1.3.6.1.4.1.5504.2.4.1.3
sechtor100ConfigEntryAn entry in the sechtor100ConfigTable.
Sechtor100ConfigEntry
.1.3.6.1.4.1.5504.2.4.1.3.1
sechtor100PeerMacAddressThis is the Mac address of the peer s100 unit.rw
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.5504.2.4.1.3.1.1
sechtor100RedundancyEnableWhether or not the redundancy functionality has been enabled. If this value is false, redundancy is not enable.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.5504.2.4.1.3.1.2
sechtor100FanOperationalStatusThis variable describes the working status of the four fans for the Sechtor 100. If any one of the four fans is not running correctly, this variable shows 'fanFailure'. When all the fans are working, the value of this variable is 'operational'.ro
Enumeration
.1.3.6.1.4.1.5504.2.4.1.3.1.3
sechtor100ThermoAUpperThresholdThis variable specifies the upper threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is above this value, s100ThermoAOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 65 degrees Celsius.rw
Integer32
.1.3.6.1.4.1.5504.2.4.1.3.1.4
sechtor100ThermoBUpperThresholdThis variable specifies the upper threshold for thermometer B in degrees Celsius. When s100ThermoBTemperature is above this value, s100ThermoBOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 60 degrees Celsius.rw
Integer32
.1.3.6.1.4.1.5504.2.4.1.3.1.5
sechtor100ThermoALowerThresholdThis variable specifies the lower threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoAOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius.rw
Integer32 (-10..5)
.1.3.6.1.4.1.5504.2.4.1.3.1.6
sechtor100ThermoBLowerThresholdThis variable specifies the lower threshold for thermometer B in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoBOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius.rw
Integer32 (-10..5)
.1.3.6.1.4.1.5504.2.4.1.3.1.7
sechtor100ThermoATemperatureThe temperature in degrees Celsius read by the IC thermometer sensor A on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer A is located. The valid temperature range for the thermometer is -55..125 degrees Celsius.ro
Integer32 (-55..125)
.1.3.6.1.4.1.5504.2.4.1.3.1.8
sechtor100ThermoBTemperatureThe temperature in degrees Celsius read by the IC thermometer sensor B on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer B is located. The valid temperature range for the thermometer is -55..125 degrees Celsius.ro
Integer32 (-55..125)
.1.3.6.1.4.1.5504.2.4.1.3.1.9
sechtor100ThermoAOperationalStatusThe operational status indicator for thermometer A. Valid values are: * withinOperationalRange - s100ThermoATemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoATemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoATemperature is lower than its lower threshold.ro
Enumeration
.1.3.6.1.4.1.5504.2.4.1.3.1.10
sechtor100ThermoBOperationalStatusThe operational status indicator for thermometer B. Valid values are: * withinOperationalRange - s100ThermoBTemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoBTemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoBTemperature is lower than its lower threshold.ro
Enumeration
.1.3.6.1.4.1.5504.2.4.1.3.1.11
sechtor100RowStatusUsed to control row creation and deletion. A row in this table is created using a single SNMP SET request with varbinds for: a) sechtor100RowStatus set to'CreateAndGo', b) the following READ-CREATE object(s): * If 'createAndGo' successfully created a new row, the RowStatus will be 'active'. Subsequent to successful row creation, the RowStatus can be retrieved via an SNMP GET and the returned RowStatus value is active. If the 'createAndGo' was unsuccessful an SNMP error will be returned and a subsequent GET on the non-existent row will also return an SNMP error of noSuchInstance. An SNMP SET with the RowStatus value of 'destroy' indicates that the agent should remove the row from service and then delete it.rw
ZhoneRowStatus (Zhone-TC)
.1.3.6.1.4.1.5504.2.4.1.3.1.12
zhoneSechtor100MIB module for elements specific to Sechtor 100 products.
MODULE-IDENTITY
.1.3.6.1.4.1.5504.6.19