Home/Catalog/ZHONE-FS-ALARM

ZHONE-FS-ALARM

AI MIB Summary

The ZHONE-FS-ALARM MIB module defines SNMP trap structures for forwarding Fault Service alarms generated by Zhone FS (Fault Service) hardware or software components. This module enables network management systems to receive real-time notifications regarding specific fault conditions and service disruptions within the Zhone Fault Service environment.

MIB module to define a trap, that will be used to forward alarms generated Fault Service.
Main OID:
faultServiceAlarm.1.3.6.1.4.1.5504.2.7.1
25
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

25 total
Object Name
faultServiceAlarmMIB module to define a trap, that will be used to forward alarms generated Fault Service.
MODULE-IDENTITY
.1.3.6.1.4.1.5504.2.7.1
faultServiceDefinitionsVariable bindings contained in a Fault Service trap are defined here.
OBJECT IDENTIFIER
.1.3.6.1.4.1.5504.2.7.1.1
alarmNameAlarm name.ro
OCTET STRING
.1.3.6.1.4.1.5504.2.7.1.1.1
alarmDescriptionAlarm description.ro
OCTET STRING
.1.3.6.1.4.1.5504.2.7.1.1.2
alarmTypeEntity type on which the alarm was generated.ro
OCTET STRING
.1.3.6.1.4.1.5504.2.7.1.1.3
alarmSeveritySeverity of alarm.ro
Enumeration
.1.3.6.1.4.1.5504.2.7.1.1.4
alarmTimestampDate and Time when the alarm was received or cleared.ro
OCTET STRING
.1.3.6.1.4.1.5504.2.7.1.1.5
alarmDeviceIP address of the device on which alarm was generated.ro
IpAddress
.1.3.6.1.4.1.5504.2.7.1.1.6
alarmShelfShelf number on which the alarm was generated.ro
Integer32
.1.3.6.1.4.1.5504.2.7.1.1.7
alarmSlotSlot number on which the alarm was generated.ro
Integer32
.1.3.6.1.4.1.5504.2.7.1.1.8
alarmPortPort number on which the alarm was generated.ro
Integer32
.1.3.6.1.4.1.5504.2.7.1.1.9
alarmSubPortSubPort number on which the alarm was generated.ro
Integer32
.1.3.6.1.4.1.5504.2.7.1.1.10
alarmDeviceNameDevice name on which the alarm was generated.ro
OCTET STRING
.1.3.6.1.4.1.5504.2.7.1.1.11
alarmCpeInternalFor alarms on CPEs. True if alarm was reported by the CPE itself in response to a physical condition on the CPE or on one of its ports.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.5504.2.7.1.1.12
alarmCpePortTypeFor alarms on CPE ports. This is the type of port for which the alarm is being reported. For OMCI ONTs, the is the ME id.ro
Integer32
.1.3.6.1.4.1.5504.2.7.1.1.13
alarmCpePortIdFor alarms on CPE ports. This is the identifier of the CPE port for which the alarm is being generated.ro
Integer32
.1.3.6.1.4.1.5504.2.7.1.1.14
faultServiceTrapsTraps that will be generated by Fault Service are defined here.
OBJECT IDENTIFIER
.1.3.6.1.4.1.5504.2.7.1.2
faultServiceV2TrapsDefinition for specification of v2 traps.
OBJECT IDENTIFIER
.1.3.6.1.4.1.5504.2.7.1.2.0
alarmReceivedAlarm received definition
NOTIFICATION-TYPE
.1.3.6.1.4.1.5504.2.7.1.2.0.1
alarmClearedAlarm clearing trap.
NOTIFICATION-TYPE
.1.3.6.1.4.1.5504.2.7.1.2.0.2
faultServiceCompliancesGroup definition for V2 compliance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.5504.2.7.1.3
faultServiceGroupsGroup specifications for fault service.
OBJECT IDENTIFIER
.1.3.6.1.4.1.5504.2.7.1.3.1
faultServiceAlarmGroupFault Service Group.
Unknown
.1.3.6.1.4.1.5504.2.7.1.3.1.1
faultServiceTrapGroupDescription.
Unknown
.1.3.6.1.4.1.5504.2.7.1.3.1.2
faultServiceImportsObjects imported from other mibs to serve as bindings in the ZMS traps
OBJECT IDENTIFIER
.1.3.6.1.4.1.5504.2.7.1.4