ZHNSYSTEM
AI MIB Summary
The ZHNSYSTEM MIB module provides vendor-specific SNMP extensions for Zhone Technologies hardware to monitor core system health metrics, including CPU utilization, memory usage, and device uptime. These objects enable centralized management of the underlying operating system state and physical resource availability for Zhone network access servers and DSLAMs.
This file defines the private Enterprise MIB extensions that define system related objects. ============================================================== == == == Copyright (C) 2008-2012 Zhone Technologies, Inc. == == == ==============================================================
Main OID:
zhnSystem.1.3.6.1.4.1.5504.2.5.2
193
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
193 total| Object Name |
|---|
zhnSystemThis file defines the private Enterprise MIB extensions that define system related objects. ============================================================== == == == Copyright (C) 2008-2012 Zhone Technologies, Inc. == == == ============================================================== MODULE-IDENTITY .1.3.6.1.4.1.5504.2.5.2 |
zhnSystemObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1 |
zhnSystemGeneralObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.1 |
modelNumbermodel no. of the devicero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.1.1 |
macBaseAddressFirst MAC Address in seriesro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.1.2 |
numberOfMacAddressesNumber of MAC Address sequentially defined in the Unit starting at the MAC Base Address.ro Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.1.3 |
wifiNetworkTypeDefines the Network Type or Mode of the Unit, i.e. Mesh or Base Stationrw WFNT .1.3.6.1.4.1.5504.2.5.2.1.1.4 |
powerSupplyTypeType of Power Supply that the unit is usingro UPT .1.3.6.1.4.1.5504.2.5.2.1.1.5 |
locationLatitudeThe latitude of the unit's location represented in degrees decimal. The format of the location's latitude is: [+ | -]ddd.dddddddd where + indicates north - indicates south d is a decimal digit (0 <= d <= 9) Valid range is -90 to +90 degrees.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.1.6 |
locationLongitudeThe longitude of the unit's location represented in degrees decimal. The format of the location's longitude is: [+ | -]ddd.dddddddd where + indicates east - indicates west d is a decimal digit (0 <= d <= 9) Valid range is -180 to +180 degrees.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.1.7 |
zhnSystemActionAction parameter to handle the action on other scalars.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.1.8 |
zhnSysLocationSystem location. This object is synonomous with the MIB II system sysLocation object.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.1.9 |
zhnSysContactSystem contact. This object is synonomous with the MIB II system sysContact object.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.1.10 |
sysTransmitClockSourceT1 Clock source for PWE device. Since both T1/E1 interfaces will be required to have the same source, this object will replace the dsx1TransmitClockSource object in the DS1-MIB. This object is not supported by ZNID devices.rw TCSI .1.3.6.1.4.1.5504.2.5.2.1.1.11 |
sysLocalTimingReferenceSource of the sysTransmitClockSource when set to Local. This object is not supported by ZNID devices.rw LTRI .1.3.6.1.4.1.5504.2.5.2.1.1.12 |
sysSynchronizationModeDetermines the method of ensuring Service Clock synchronization between the Source and Remote PWE devices.rw CSMI .1.3.6.1.4.1.5504.2.5.2.1.1.13 |
sysSynchronousEthernetDetermines whether or not to use the 25MHz clock derived from the Synchronous Ethernet Port. This object is not supported by ZNID devices.rw SEI .1.3.6.1.4.1.5504.2.5.2.1.1.14 |
sysClockModeDetermines the mode for which the PWE chip will be initialized.rw CMI .1.3.6.1.4.1.5504.2.5.2.1.1.15 |
sysCfgDBActionPerform an action on the configuration database.rw CDA .1.3.6.1.4.1.5504.2.5.2.1.1.16 |
sysSoftwareRebootPerform a software reboot.rw RBT .1.3.6.1.4.1.5504.2.5.2.1.1.17 |
sysSystemClockSourceDetermines the system-level clock mode for ZNID devices. uplink - the system will recover its clock from the configured uplink (e.g. GPON, SPF1, SFP2, etc.). ds1 - the system will recover its clock from the configured sysDs1ClockSourcePort. ieee1588 - the system will recover clock from the on-board 1588 clock circuitry.rw SCS .1.3.6.1.4.1.5504.2.5.2.1.1.18 |
sysEthernetTransmitClockSourceDetermines the transmit clock source for all ethernet ports requiring a clock. internal - all ethernet ports will recover clock from the local oscillator. systemClock - all ethernet ports will recover clock from the sysSystemClockSource.rw ETCS .1.3.6.1.4.1.5504.2.5.2.1.1.19 |
sysDs1ClockSourcePortThe interface name for the DS1 port providing transmit clock when the sysSystemClockSource is set to ds1.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.1.20 |
sysBootloaderVersionSystem bootloader (CFE) firmware version.ro OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.1.21 |
sysFirmwareVersionThe version of firmware the system is currently running.ro OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.1.22 |
sysAltFirmwareVersionThe alternate firmware version currently stored in system flash.ro OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.1.23 |
sysRestoreAltFirmwareVersionThis object can be used to restore the version of firmware to the alternate firmware version currently stored in flash.rw SysFirmwareAction .1.3.6.1.4.1.5504.2.5.2.1.1.24 |
sysSnmpProvisioningLockThis object can be set by an SNMP client to indicate that system configuration is in progress. All other SNMP clients will be locked out while this is set to true. This lock will timeout after 30 seconds.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.1.25 |
sysSnmpProvisioningChangeThis object can be incremented by SNMP clients to indicate a sysCfgDBAction save has taken place.rw Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.1.26 |
zhnSystemBoardObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.2 |
numberOfBoardsNumber of boards in the Unit with Name, Part Number, Serial Number and Revision Number valuesro Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.2.1 |
boardDescriptorTableTable of boards: Name, Part Number, Serial Number and Revision Number values SEQUENCE OF BoardDescriptorEntry .1.3.6.1.4.1.5504.2.5.2.1.2.2 |
boardDescriptorEntryTable of boards: Name, Part Number, Serial Number and Revision Number values BoardDescriptorEntry .1.3.6.1.4.1.5504.2.5.2.1.2.2.1 |
boardIndexBoard Index (Zero relative) Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.2.2.1.1 |
boardNameName of the Board as created by the systemro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.2.2.1.2 |
boardPartNumberPart Number of the Board. Read from the boardro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.2.2.1.3 |
boardSerialNumberSerial Number of the Board. Read from the boardro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.2.2.1.4 |
boardRevisionRevision Number of the Board. Read from the boardro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.2.2.1.5 |
zhnSystemPldObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.3 |
numberOfPldsNumber of PLDs in the Unit with Name and Version Number valuesro Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.3.1 |
pldDescriptorTableTable of boards: Name, Part Number, Serial Number and Revision Number values SEQUENCE OF PldDescriptorEntry .1.3.6.1.4.1.5504.2.5.2.1.3.2 |
pldDescriptorEntryTable of boards: Name, Part Number, Serial Number and Revision Number values PldDescriptorEntry .1.3.6.1.4.1.5504.2.5.2.1.3.2.1 |
pldIndexPLD Index (Zero relative) Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.3.2.1.1 |
pldNameName of the PLD as created by the systemro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.3.2.1.2 |
pldVersionPLD Software Version. Read from the PLDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.3.2.1.3 |
zhnSystemRadioObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.4 |
numberOfRadiosNumber of Radios in the Unitro Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.4.1 |
zhnSystemEthernetLikeObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.5 |
numberOfEthernetLikeInterfacesNumber of Ethernet Like Interfaces with Name, Type and Subtyperw Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.5.1 |
ethernetlikeInterfaceTableTable of ethernet-like Interfaces SEQUENCE OF EthernetlikeInterfaceEntry .1.3.6.1.4.1.5504.2.5.2.1.5.2 |
ethernetlikeInterfaceEntryTable of ethernet-like interfaces having Name, type, subtype, number of ports, line power and number of pairs with power EthernetlikeInterfaceEntry .1.3.6.1.4.1.5504.2.5.2.1.5.2.1 |
etherIndexIndex of the Ethernet Like Interface (zero relative) Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.5.2.1.1 |
etherNameName of the ethernet Like Interface as created by the systemro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.5.2.1.2 |
etherTypeType of Ethernet interfacero ELTYPE .1.3.6.1.4.1.5504.2.5.2.1.5.2.1.3 |
etherSubtypeSubtype of Ethernet interfacero ELSUBTYPE .1.3.6.1.4.1.5504.2.5.2.1.5.2.1.4 |
etherNumberOfPortsNumber of Ports on the Ethernet interfacero Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.5.2.1.5 |
etherLinePowerLine Power Type on this Ethernet Interfacero LPT .1.3.6.1.4.1.5504.2.5.2.1.5.2.1.6 |
etherPowerPairsNumber of line Pairs providing power on the Ethernet interfacero Integer32 .1.3.6.1.4.1.5504.2.5.2.1.5.2.1.7 |
zhnSystemTempSensorObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.6 |
numberOfTemperatureSensorsNumber of Temperature Sensors in the Unitro Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.6.1 |
temperatureSensorTableTable of Temperature Sensors: Name, Maximum, and Minimum values SEQUENCE OF TemperatureSensorEntry .1.3.6.1.4.1.5504.2.5.2.1.6.2 |
temperatureSensorEntryTable of Temperature Sensors: Name, Maximum, and Minimum values TemperatureSensorEntry .1.3.6.1.4.1.5504.2.5.2.1.6.2.1 |
temperatureSensorIndexTemperature Sensor Index (Zero relative) Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.6.2.1.1 |
temperatureSensorNameName of the ethernet Like Interface as created by the systemro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.6.2.1.2 |
temperatureSensorMaximumMaximum Temperature Recordedro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.6.2.1.3 |
temperatureSensorMinimumMinimum Temperature Recordedro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.6.2.1.4 |
zhnSystemSNMPObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.7 |
numberOfCommunitiesNumber of SNMP Communities configured in the Unitro Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.7.1 |
zhnCommunityTableThis table is used to set the various configuration parameters for a particular community. SEQUENCE OF ZhnCommunityTableEntry .1.3.6.1.4.1.5504.2.5.2.1.7.2 |
zhnCommunityTableEntryThis object corresponds to an entry in the community table. ZhnCommunityTableEntry .1.3.6.1.4.1.5504.2.5.2.1.7.2.1 |
communityNameThis object corresponds to the SNMP community string. DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.7.2.1.1 |
communityTypeThe access type of the community string. The default value of this object should be read-only(1).rw Enumeration .1.3.6.1.4.1.5504.2.5.2.1.7.2.1.2 |
communityRowStatusWhen written, this object can be used to createAndGo(4) or destroy(6) a row from the table. A rowStatus value of notInService(2) will also destroy a row. RowStatus values of active(1), notReady(3), and createAndWait(5) are ignored.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.7.2.1.3 |
zhnFixedCommunityTableThis table is used to configure a read-only and a read-write community. SEQUENCE OF ZhnFixedCommunityTableEntry .1.3.6.1.4.1.5504.2.5.2.1.7.3 |
zhnFixedCommunityTableEntryThis object corresponds to an entry in the fixed community table. ZhnFixedCommunityTableEntry .1.3.6.1.4.1.5504.2.5.2.1.7.3.1 |
fixedCommunityNameThis object corresponds to the SNMP community string.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.7.3.1.1 |
fixedCommunityTypeThe access type of the community string. The default value of this object should be read-only(1).rw Enumeration .1.3.6.1.4.1.5504.2.5.2.1.7.3.1.2 |
fixedCommunityRowStatusWhen written, this object is ignored. When read, a value of active(1) or notReady(3) will be returned.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.7.3.1.3 |
zhnSystemTrapObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.8 |
numberOfTrapManagersNumber of Trap Managers configured in the Unitro Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.8.1 |
zhnDefaultTrapCommunityThis object corresponds to the default trap community string. The default trap community string will be used when a community name is not configured for a particular trap manager.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.8.2 |
zhnTrapTypeLinkUpDownEnable or disable all link up/down traps.rw Enumeration .1.3.6.1.4.1.5504.2.5.2.1.8.3 |
zhnTrapTypeAuthFailureEnable or disable the generation of authorization failure traps.rw Enumeration .1.3.6.1.4.1.5504.2.5.2.1.8.4 |
zhnTrapTypeConfigChangeEnable or disable the generation of configuration change traps. This object is not supported by ZNID devices. Rather, the only mechanism to disable the generation of configuration change traps in a ZNID device is to disable the generation of all enterprise traps via the zhnTrapTypeEnterpise object.rw Enumeration .1.3.6.1.4.1.5504.2.5.2.1.8.5 |
zhnTrapManagerInfoTableThis table is used to set the trap destination address for a particular community. SEQUENCE OF ZhnTrapManagerInfoTableEntry .1.3.6.1.4.1.5504.2.5.2.1.8.6 |
zhnTrapManagerInfoTableEntryThis object corresponds to an entry in the community trap address info table. ZhnTrapManagerInfoTableEntry .1.3.6.1.4.1.5504.2.5.2.1.8.6.1 |
trapDestinationThe IP Address of the destination to which a trap must be sent. IpAddress .1.3.6.1.4.1.5504.2.5.2.1.8.6.1.1 |
trapCommunityNameThis object corresponds to the trap community string. If not specified, the trapCommunityName will be set to the zhnDefaultTrapCommunity object.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.8.6.1.2 |
trapVersionThe trap types automatically supported by net-snmp and enabled/disabled in snmpd.conf. If not specified, the trapVersion will be set the default value of v2c.rw Enumeration .1.3.6.1.4.1.5504.2.5.2.1.8.6.1.3 |
trapPortThe udp/tcp port number to which a trap must be sent. If not specified, the trapPort will be set the default value of 162.rw INTEGER .1.3.6.1.4.1.5504.2.5.2.1.8.6.1.4 |
trapRowStatusWhen written, this object can be used to createAndGo(4) or destroy(6) a row from the table. A rowStatus value of notInService(2) will also destroy a row. RowStatus values of active(1), notReady(3), and createAndWait(5) are ignored.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.8.6.1.5 |
zhnTrapTypeColdStartEnable or disable the generation of coldstart traps. A coldstart trap is generated each time the device is restarted.rw Enumeration .1.3.6.1.4.1.5504.2.5.2.1.8.7 |
zhnTrapTypeWarmStartEnable or disable the generation of warmstart traps. A warmstart trap is generated each time the device's SNMP agent is restarted.rw Enumeration .1.3.6.1.4.1.5504.2.5.2.1.8.8 |
zhnTrapTypeEnterpriseEnable or disable the generation of all enterprise traps.rw Enumeration .1.3.6.1.4.1.5504.2.5.2.1.8.9 |
zhnSystemSyslogObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.9 |
sysLogAdminStatusEnable or disable the Syslog service.rw SysAdminStatus .1.3.6.1.4.1.5504.2.5.2.1.9.1 |
sysLogLocalLogLevelSysLog local log level options, per RFC 3164. All logged events with a severity at or greater than this level will be logged to the local log file. Note, the local log file is not persistent across system reboots.rw SysLogLevel .1.3.6.1.4.1.5504.2.5.2.1.9.2 |
sysLogRemoteLogLevelSysLog remote log level options, per RFC 3164. All logged events with a severity at or greater that this level will be sent to a remote Syslog server if the remote server address is configured and a route exists to the remote server.rw SysLogLevel .1.3.6.1.4.1.5504.2.5.2.1.9.3 |
sysLogDisplayLogLevelSysLog log level options, per RFC 3164 for the display of log messages via a web browser. All logged events with a severity level at or greater than this level will be displayed.rw SysLogLevel .1.3.6.1.4.1.5504.2.5.2.1.9.4 |
sysLogModeSysLog logging mode of operation: local(1), -- Log messages only to the local, non-persistent log file remote(2), -- Log messages only to a remote syslog server both(3), -- Log messages to both a local log file and a remote syslog serverrw SysLogMode .1.3.6.1.4.1.5504.2.5.2.1.9.5 |
sysLogRemoteServerAddressThe IP address of the remote syslog server.rw IpAddress .1.3.6.1.4.1.5504.2.5.2.1.9.6 |
sysLogRemoteServerPortThe UDP port to use to transfer syslog messages to the remote syslog server.rw Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.9.7 |
zhnSystemSNTPObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.10 |
sntpAdminStatusEnable or disable the SNTP client.rw SysAdminStatus .1.3.6.1.4.1.5504.2.5.2.1.10.1 |
sntpOperStatusCurrent operational status of the SNTP client.rw SysAdminStatus .1.3.6.1.4.1.5504.2.5.2.1.10.2 |
sntpServer1The domain name or IP address of the first SNTP server with which to synchronize the system time.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.10.3 |
sntpServer2The domain name or IP address of the second SNTP server with which to synchronize the system time.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.10.4 |
sntpServer3The domain name or IP address of the third SNTP server with which to synchronize the system time.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.10.5 |
sntpServer4The domain name or IP address of the fourth SNTP server with which to synchronize the system time.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.10.6 |
sntpServer5The domain name or IP address of the fifth SNTP server with which to synchronize the system time.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.10.7 |
sntpLocalTimeZoneIndicates the local time zone.rw SysSntpTimeZones .1.3.6.1.4.1.5504.2.5.2.1.10.8 |
sntpCurrentDateAndTimeIndicates the current date and time.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.10.9 |
zhnSystemUserLoginObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.11 |
adminUserNameThe username required to login as the system administrator. This user has unrestricted access to change and view all configuration, status and test parameters.ro OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.11.1 |
adminPasswordThe password required to login as the system administrator. This field cannot contain a SPACE and is returned as a string of asterisks.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.11.2 |
supportUserNameThe username required to login to support the system. This user has access to system parameters required to maintain the system and run diagnostic tests.ro OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.11.3 |
supportPasswordThe password required to login to support the system. This field cannot contain a SPACE and is returned as a string of asterisks.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.11.4 |
userUserNameThe username required to login as a general user of the system. This user can view configuration settings and statistics, as well as, update the system's software.ro OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.11.5 |
userPasswordThe password required to login as a general user of the system. field cannot contain a SPACE and is returned as a string of asterisks.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.11.6 |
zhnSystemPowerSheddingObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.12 |
powerSheddingAdminStatusConfiguration of parameters for the power-shedding feature. The power-shedding objects are only supported by systems that include on-board power-management circuitry. When the system detects that it is running on battery power, it has the option to shut down all support (excluding the voice over IP telephone service).The power-shedding administrative state will enable or disable the power-shedding feature.ro SysAdminStatus .1.3.6.1.4.1.5504.2.5.2.1.12.1 |
powerSheddingShutdownDelayThe shutdown delay is the time delay, in minutes, after AC power is lost, before shutting down non-voice services.ro Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.12.2 |
powerSheddingRestoreDelayThe restore delay is the time delay, in minutes, after AC power is restored before switching on the services that were shut down due to the power loss.ro Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.12.3 |
zhnSystemFirewallObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.13 |
sysFirewallEnableEnables or disables the firewall feature for the entire system.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.13.1 |
sysFirewallTcpSynCookiesEnables or disables the TCP SYNCookie protection against SYN flooding denial-of-service attack.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.13.2 |
zhnSystemDNSClientObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.14 |
sysDNSAddressingTypeType of IP interface addressing method used to reach the DNS.rw IPInterfaceAddressingTypeValues .1.3.6.1.4.1.5504.2.5.2.1.14.1 |
sysDNSDHCPSourceName of the interface used by the DHCP Client to obtain DNS information.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.14.2 |
sysDNSPrimaryIPAddressPrimary Address of DNS when the addressing type is set to Static.rw IpAddress .1.3.6.1.4.1.5504.2.5.2.1.14.3 |
sysDNSSecondaryIPAddressSecondary Address of DNS when the addressing type is set to Static.rw IpAddress .1.3.6.1.4.1.5504.2.5.2.1.14.4 |
zhnSystemDNSProxyObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.15 |
zhnDnsProxyHostMaxHostEntriesThe maximum number of host entries in the DnsProxyHostObjectTable.rw Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.15.1 |
zhnDnsProxyHostTableThis table is used to configure a DNS Proxy Host entry. SEQUENCE OF ZhnDnsProxyHostEntry .1.3.6.1.4.1.5504.2.5.2.1.15.2 |
zhnDnsProxyHostEntryThis object corresponds to an entry in the DNS Proxy Host table. ZhnDnsProxyHostEntry .1.3.6.1.4.1.5504.2.5.2.1.15.2.1 |
dnsProxyHostIndexIndex into the DNS Proxy Host table Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.15.2.1.1 |
dnsProxyHostIPAddressThe local proxy host IP address.rw IpAddress .1.3.6.1.4.1.5504.2.5.2.1.15.2.1.2 |
dnsProxyHostNameThe domain name assigned to the host IP address.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.15.2.1.3 |
dnsProxyRowStatusCreate or destroy a DNS Proxy Host. Upon creation, the dnsProxyHostIPAddress must be provided.rw ZhoneRowStatus (Zhone-TC) .1.3.6.1.4.1.5504.2.5.2.1.15.2.1.4 |
zhnSystemWanBackupObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.16 |
failoverTimerThe WAN Failover Timer is used to determine how long (in seconds) the Fiber uplink interface must be operationally DOWN before a USB Cellular WAN Backup connection will be initiated. The Default value is 0 seconds, which DISABLES this feature. The recommended value to enable this feature is 60 seconds.rw Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.16.1 |
restoralTimerThe WAN Restoral Timer is used to determine how long (in seconds) the Fiber uplink interface must remain in an operational UP condition before the Cellular Backup connection will be terminated and the traffic that was being forwarded out the USB interface is forwarded to the 5xx GEM instead. The default value is 60 seconds.rw Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.16.2 |
backupDataVlanThis is the Internet Access VLAN (GEM 5xx), which is the only service that can be backed up using the USB Cellular modem.rw Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.16.3 |
cellularPinNumberA 4 digit PIN code used to unlock the SIM card. For GPRS/UMTS networks, *99# is typically used. For CDMA/EVDO networks, #777 is typically used.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.16.4 |
cellularDataNumberThis is the number that the USB modem will dial to establish a cellular a cellular data connection. For GPRS/UMTS networks, *99# is typically used. For CDMA/EVDO networks, #777 is typically used.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.16.5 |
atInitCommandsAT initialization command strings, if needed.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.16.6 |
accessPointNameThe Access Point Name (APN) for connections to the GPRS/UMTS network. This should be provided by the ISP. In North America, 3G cellular carriers do not require an APN.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.16.7 |
chapPapUsernameRequired for CHAP or PAP authentication. This configuration item should be left blank if CHAP or PAP is not used.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.16.8 |
chapPapPasswordRequired for CHAP or PAP authentication. This configuration item should be left blank if CHAP or PAP is not used.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.16.9 |
connectionTimeoutSpecifies the duration of inactivity in seconds before the cellular data call will automatically terminate. A new call will be initiated automatically when a packet must be sent upstream on the designated VLAN if the WAN uplink is still Operationally Down. A value of 0 will DISABLE the Connection Timeout feature.rw Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.16.10 |
backupIpAddressModeThe WAN IP Address, Default Gateway IP Address, Subnet Mask and DNS Server IP Address must all be defined for the USB Cellular Backup connection. When IP Address Mode is set to DHCP, a DHCP Request will be sent upstream after the Cellular Data Connection has been established to acquire this information dynamically. When the WAN Backup IP Addess Mode is set to Static, this information ust be statically configured.rw BasicAddressingTypeValues .1.3.6.1.4.1.5504.2.5.2.1.16.11 |
backupIpAddressThe IP Address to be used on the WAN uplink interface of a Cellular Backhaul connection. This parameter is acquired dynamically in DHCP mode and only configurable if the BackupIpAddressMode is Static.rw IpAddress .1.3.6.1.4.1.5504.2.5.2.1.16.12 |
backupDefaultGatewayThe IP Address of the Default Gateway to be used on the WAN uplink interface of a Cellular Backhaul connection. This parameter is acquired dynamically in DHCP mode and only configurable if the BackupIpAddressMode is Static.rw IpAddress .1.3.6.1.4.1.5504.2.5.2.1.16.13 |
backupSubnetMaskThe Subnet Mask to be used on the WAN uplink interface of a Cellular Backhaul connection. This parameter is acquired dynamically in DHCP mode and only configurable if the BackupIpAddressMode is Static.rw IpAddress .1.3.6.1.4.1.5504.2.5.2.1.16.14 |
backupPrimaryDnsThe IP Address of the Primary DNS Server to be used on the WAN uplink interface of a Cellular Backhaul connection. This parameter is acquired dynamically in DHCP mode and only configurable if the BackupIpAddressMode is Static.rw IpAddress .1.3.6.1.4.1.5504.2.5.2.1.16.15 |
backupSecondaryDnsThe IP Address of the Secondary DNS Server to be used on the WAN uplink interface of a Cellular Backhaul connection. This parameter is acquired dynamically in DHCP mode and only configurable if the BackupIpAddressMode is Static.rw IpAddress .1.3.6.1.4.1.5504.2.5.2.1.16.16 |
zhnSystemTr69cObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.17 |
sysTr69cConfigObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.17.1 |
sysTr69cConfigLoggingSOAPEnable or disable showing SOAP messages on serial console and local TR69 Client log file.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.17.1.1 |
sysTr69cConfigConnectionRequestAuthenticationEnable or disable connection request authentication.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.17.1.2 |
sysTr69cServerObjects OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.1.17.2 |
sysTr69cServerURLURL for the CPE to connect to the ACS using the CPE WAN Management Protocol. This parameter MUST be in the form of a valid HTTP or HTTPS URL. The host portion of this URL is used by the CPE for server-side certificate authentication when using SSL or TLS.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.17.2.1 |
sysTr69cServerLastConnectedURLThis value records the last URL which connected successfully to the TR69 client.ro OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.17.2.2 |
sysTr69cServerUsernameUsername used to authenticate the CPE when making a connection to the ACS using the CPE WAN Management Protocol. This username is used only for HTTP-based authentication of the CPE.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.17.2.3 |
sysTr69cServerPasswordPassword used to authenticate the CPE when making a connection to the ACS using the CPE WAN Management Protocol. This username is used only for HTTP-based authentication of the CPE. When read by an ACS, this parameter returns an empty string, regardless of the value.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.17.2.4 |
sysTr69cServerPeriodicInformEnableWhen set to TRUE, the CPE will periodically send CPE information to the TR69 Server using the Inform method calls.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.17.2.5 |
sysTr69cServerPeriodicInformIntervalThe duration in seconds of the interval for which the CPE MUST attempt to connect with the ACS and call the Inform method if PeriodicInform-Enable is true.rw Unsigned32 .1.3.6.1.4.1.5504.2.5.2.1.17.2.6 |
sysTr69cServerParameterKeyParameterKey provides the ACS a reliable and extensible means to track changes made by the ACS. The value of ParameterKey MUST be equal to the value of the ParameterKey argument from the most recent successful SetParameterValues, AddObject, or DeleteObject method call from the ACS. The CPE MUST set ParameterKey to the value specified in the corresponding method arguments if and only if the method completes successfully and no fault response is generated. If a method call does not complete successfully implying that the changes requested in the method did not take effect, the value of ParameterKey MUST NOT be modified. The CPE MUST only modify the value of ParameterKey as a result of SetParameterValues, AddObject, DeleteObject, or due to a factory reset. On factory reset, the value of ParameterKey MUST be set to empty.ro OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.17.2.7 |
sysTr69cServerBoundIfNameName of the WAN interface that the TR69 client should use when establishing communications with the ACS.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.17.2.8 |
sysTr69cServerConnectionRequestURLHTTP URL for an ACS to make a Connection Request notification to the CPE. In the form: http://host:port/path. The host portion of the URL MAY be the IP address for the management interface of the CPE in lieu of a host name.ro OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.17.2.9 |
sysTr69cServerConnectionRequestUsernameUsername used to authenticate an ACS making a Connection Request to the CPE.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.17.2.10 |
sysTr69cServerConnectionRequestPasswordPassword used to authenticate an ACS making a Connection Request to the CPE. When read by an ACS, this parameter returns an empty string, regardless of the actual value.rw OCTET STRING .1.3.6.1.4.1.5504.2.5.2.1.17.2.11 |
sysTr69cServerUpgradesManagedIndicates whether or not the ACS will manage upgrades for the CPE. If true (1), the CPE SHOULD not use other means other than the ACS to seek out available upgrades. If false (0), the CPE MAY use other means for this purpose.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.5504.2.5.2.1.17.2.12 |
zhnSystemConformance OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.2 |
zhnSystemGroups OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.2.1 |
zhnSystemActiveGroupA collection of System Information objects that are required for the device to be functional Unknown .1.3.6.1.4.1.5504.2.5.2.2.1.1 |
zhnSystemTablesItemsThe table items for the device that are filled in when the table is present Unknown .1.3.6.1.4.1.5504.2.5.2.2.1.2 |
zhnSystemConfigItemsThe collection of configurable scalar system objects. Unknown .1.3.6.1.4.1.5504.2.5.2.2.1.3 |
zhnSystemTrapItemsThe collection of SNMP trap objects. Unknown .1.3.6.1.4.1.5504.2.5.2.2.1.4 |
zhnSystemCommunityItemsThe collection of SNMP community objects. Unknown .1.3.6.1.4.1.5504.2.5.2.2.1.5 |
zhnSystemFixedCommunityItemsThe collection of pre-provisioned SNMP community objects. Unknown .1.3.6.1.4.1.5504.2.5.2.2.1.6 |
zhnSystemClockingItemsThe collection of system-wide clocking parameters only supported by ZNID devices. Unknown .1.3.6.1.4.1.5504.2.5.2.2.1.7 |
zhnSyslogConfigGroupThe collection of system-wide logging parameters only supported by ZNID devices. Unknown .1.3.6.1.4.1.5504.2.5.2.2.1.8 |
zhnSntpConfigGroupThe collection of SNTP server parameters only supported by ZNID devices. Unknown .1.3.6.1.4.1.5504.2.5.2.2.1.9 |
zhnUserLoginGroupThe collection of User login parameters only supported by ZNID devices. Unknown .1.3.6.1.4.1.5504.2.5.2.2.1.10 |
zhnPowerSheddingGroupThe collection of configurable power-shedding parameters only supported by ZNID devices. Unknown .1.3.6.1.4.1.5504.2.5.2.2.1.11 |
zhnSystemFirewallGroupThe collection of system firewall parameters only supported by ZNID devices. Unknown .1.3.6.1.4.1.5504.2.5.2.2.1.12 |
zhnSystemDNSClientGroupThe collection of system DNS Client parameters only supported by ZNID devices. Unknown .1.3.6.1.4.1.5504.2.5.2.2.1.13 |
zhnSystemDNSProxyHostGroupThe collection of system DNS Proxy Host parameters only supported by ZNID devices. Unknown .1.3.6.1.4.1.5504.2.5.2.2.1.14 |
zhnSystemWanBackupGroupThe collection of system WAN Backup parameters only supported by ZNID devices. Unknown .1.3.6.1.4.1.5504.2.5.2.2.1.15 |
zhnSystemTr69cGroupThe collection of system TR69 Client parameters only supported by ZNID devices. Unknown .1.3.6.1.4.1.5504.2.5.2.2.1.16 |
zhnSystemCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.5504.2.5.2.2.2 |
zhnSystemComplianceThe Compliance statement for SNMP entities which manage the display of Zhone System Information Unknown .1.3.6.1.4.1.5504.2.5.2.2.2.1 |