WWP-SYSLOG-COLLECTOR-MIB
Imported Objects
Objects
18 total| Object Name |
|---|
wwpSyslogCollectorMIBA MIB module to manage syslog collectors on the LEOS based WWP products. MODULE-IDENTITY .1.3.6.1.4.1.6141.2.46 |
wwpSyslogCollMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.6141.2.46.1 |
wwpSyslogSystem OBJECT IDENTIFIER .1.3.6.1.4.1.6141.2.46.1.1 |
wwpSyslogEnableSpecifies whether or not the syslog client is enabled. This is the system wide parameter and will overwrite any collector specific managed object to enable or disable the syslog client.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.6141.2.46.1.1.1 |
wwpSyslogColl OBJECT IDENTIFIER .1.3.6.1.4.1.6141.2.46.1.2 |
wwpSyslogCollectorTableA table containing Syslog collector information. SEQUENCE OF WwpSyslogCollectorEntry .1.3.6.1.4.1.6141.2.46.1.2.1 |
wwpSyslogCollectorEntryDefines the information pertaining to a syslog collector to which a syslog messages will be relayed. Entries within this table with an access level of read- create MUST be considered non-volatile and MUST be maintained across entity resets. WwpSyslogCollectorEntry .1.3.6.1.4.1.6141.2.46.1.2.1.1 |
wwpSyslogCollectorAddrThe Ip address for the Syslog message collector.ro IpAddress .1.3.6.1.4.1.6141.2.46.1.2.1.1.1 |
wwpSyslogCollectorUDPPortThe port number on the destination to which the syslog message will be forwarded over the udp transport.rw Integer32 .1.3.6.1.4.1.6141.2.46.1.2.1.1.2 |
wwpSyslogCollectorFacilityThe syslog facility code that will added to messages forwarded to this collector.rw SyslogFacility .1.3.6.1.4.1.6141.2.46.1.2.1.1.3 |
wwpSyslogCollectorMinSeverityAny syslog message with a severity less than the severity specified by this object will be ignored by the collector. note: serverity level numeric values increase as their severity decreases, e.g. error(3) is more severe than debug(7).rw SyslogSeverity .1.3.6.1.4.1.6141.2.46.1.2.1.1.4 |
wwpSyslogCollectorMaxSeverityAny syslog message with a severity greater than the severity specified by this object will be ignored by the collector. note: serverity level numeric values increase as their severity decreases, e.g. error(3) is more severe than debug(7).rw SyslogSeverity .1.3.6.1.4.1.6141.2.46.1.2.1.1.5 |
wwpSyslogCollectorStatusThis object is used to create and delete rows in the wwpSyslogCollectorTable. To create a new row the management station must set the object to 'CreateAndGo'. The collector can be disabled by setting this object to 'notInService'.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.6141.2.46.1.2.1.1.6 |
wwpSyslogCollMIBNotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.6141.2.46.2 |
wwpSyslogCollMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.6141.2.46.2.0 |
wwpSyslogCollMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.6141.2.46.3 |
wwpSyslogCollMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.6141.2.46.3.1 |
wwpSyslogCollMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.6141.2.46.3.2 |
More MIBs from World Wide Packets
Browse all World Wide PacketsMIBs →SNMP MIB module
The WWP-LEOS-CFM-MIB enables configuration and monitoring of IEEE 802.1ag Connectivity Fault Management (CFM) entities, including Maintenance Domains, Maintenance Associations, and Maintenance End Points, on WWP-LEOS network devices. It facilitates the retrieval of critical fault detection metrics such as Continuity Check (CC) state, Last Link Status, and Maintenance Level (ML) to verify Layer 2 connectivity integrity.
SNMP MIB module
SNMP MIB module
The WWP-LEOS-PORT-STATS-MIB module monitors Layer 2 Ethernet port statistics on WWP (Wireless WAN Platform) devices running LEOS firmware, specifically tracking interface counters such as octets, packets, errors, and discards for operational visibility and fault detection.
The WWP-LEOS-CHASSIS-MIB facilitates the retrieval of the specific system part number and serial number for WWP LEOS chassis hardware via SNMP. These object identifiers enable precise asset inventory tracking and device identification within network management systems.