Home/Catalog/WWP-8021X-MIB

WWP-8021X-MIB

Description.
Main OID:
wwp8021xMibModule.1.3.6.1.4.1.6141.2.401
27
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

27 total
Object Name
wwp8021xMibModuleDescription.
MODULE-IDENTITY
.1.3.6.1.4.1.6141.2.401
wwp8021xMIB
OBJECT IDENTIFIER
.1.3.6.1.4.1.6141.2.401.1
wwp8021xConf
OBJECT IDENTIFIER
.1.3.6.1.4.1.6141.2.401.1.1
wwp8021xGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.6141.2.401.1.1.1
wwp8021xCompls
OBJECT IDENTIFIER
.1.3.6.1.4.1.6141.2.401.1.1.2
wwp8021xObjs
OBJECT IDENTIFIER
.1.3.6.1.4.1.6141.2.401.1.2
wwp8021xPortTableTable with an entry for every port on the switch
SEQUENCE OF Wwp8021xPortEntry
.1.3.6.1.4.1.6141.2.401.1.2.1
wwp8021xPortEntryDescription.
Wwp8021xPortEntry
.1.3.6.1.4.1.6141.2.401.1.2.1.1
wwp8021xPortSwitch Ethernet Portro
INTEGER
.1.3.6.1.4.1.6141.2.401.1.2.1.1.1
wwp8021xRole802.1x role of the Port.rw
Enumeration
.1.3.6.1.4.1.6141.2.401.1.2.1.1.2
wwp8021xRadiusClient
OBJECT IDENTIFIER
.1.3.6.1.4.1.6141.2.401.1.2.2
wwp8021xRadiusClientTimeoutThis is the time in seconds between retransmissions to the RADIUS server.rw
Integer32
.1.3.6.1.4.1.6141.2.401.1.2.2.1
wwp8021xRadiusClientRetriesIndicates the number of times the RADIUS server should be tried before giving up on the server.rw
Integer32
.1.3.6.1.4.1.6141.2.401.1.2.2.2
wwp8021xRadiusDeadTimeLength of time in minutes during which a RADIUS server is skipped over by transaction requests..rw
Integer32
.1.3.6.1.4.1.6141.2.401.1.2.2.3
wwp8021xRadiusServerTableLists the possible RADIUS servers.
SEQUENCE OF Wwp8021xRadiusServerEntry
.1.3.6.1.4.1.6141.2.401.1.2.2.4
wwp8021xRadiusServerEntryRadius server entry.
Wwp8021xRadiusServerEntry
.1.3.6.1.4.1.6141.2.401.1.2.2.4.1
wwp8021xRadiusServerIdIndex to the Radius Server Entry. The radius Servers are polled according to their ServerIds. If the ServerId 1 doesn't respond, then it tries for the next and hence on.ro
Integer32
.1.3.6.1.4.1.6141.2.401.1.2.2.4.1.1
wwp8021xRadiusServerIpAddrIP Address of the RADIUS server.rw
IpAddress
.1.3.6.1.4.1.6141.2.401.1.2.2.4.1.2
wwp8021xRadiusServerAuthPortThe destination UDP port number to which RADIUS messages should be sent. The RADIUS server will not be used for authentication if this port number is 0.rw
Integer32
.1.3.6.1.4.1.6141.2.401.1.2.2.4.1.3
wwp8021xRadiusServerAuthKeyThe Auth Key to be used for Radius Servers. Retrieving the value of this object via SNMP will return an empty string for security reasonsrw
OCTET STRING
.1.3.6.1.4.1.6141.2.401.1.2.2.4.1.4
wwp8021xRadiusServerStatusTo create a row in this table, a manager must set this object to either createAndGo(4). A row in the WwpRadiusServerEntry can't be set to active until wwpRadiusServerIpAddr has been set to valid value. To disable a Radius server , the operator can set this object to 'notInSerVice' state.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.6141.2.401.1.2.2.4.1.5
wwp8021xSupplicantSecTableTable for Supplicant username and password. Has entry for every port on the switch
SEQUENCE OF Wwp8021xSupplicantSecEntry
.1.3.6.1.4.1.6141.2.401.1.2.3
wwp8021xSupplicantSecEntryThis contains the username and password entries for each port. Index is wwp8021xPort from Wwp8021xPortEntry
Wwp8021xSupplicantSecEntry
.1.3.6.1.4.1.6141.2.401.1.2.3.1
wwp8021xSupplicantSecUserNameUser name associated with port. This is only applicable if port has role of Supplicant or Bothrw
OCTET STRING
.1.3.6.1.4.1.6141.2.401.1.2.3.1.1
wwp8021xSupplicantSecPasswordPassword associated with port. This is only applicable if port has role of Supplicant or Bothrw
OCTET STRING
.1.3.6.1.4.1.6141.2.401.1.2.3.1.2
wwp8021xEvents
OBJECT IDENTIFIER
.1.3.6.1.4.1.6141.2.401.1.3
wwp8021xEventsV2
OBJECT IDENTIFIER
.1.3.6.1.4.1.6141.2.401.1.3.0
WWP-8021X-MIB - SNMP MIB Reference | MIBs Explorer