Home/Catalog/VPWR-DC-POWER-MIB

VPWR-DC-POWER-MIB

MIB Version 2.0 History Apr 26, 2007 Added SysAlarm Config Table Version 2.0 Feb 08, 2003 Changed vpwrTrapDestinationTable to vpwrTrapTable Corrected entry for vpwrTrapTable to be VpwrTrapTableEntry This fixes errors generated by MG-SOFT mib compiler.Ver1.0 Oct 30, 2002 initial release - version 0.4
Main OID:
valereDcPowerMgt.1.3.6.1.4.1.13858
132
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

132 total
Object Name
valereDcPowerMgtMIB Version 2.0 History Apr 26, 2007 Added SysAlarm Config Table Version 2.0 Feb 08, 2003 Changed vpwrTrapDestinationTable to vpwrTrapTable Corrected entry for vpwrTrapTable to be VpwrTrapTableEntry This fixes errors generated by MG-SOFT mib compiler.Ver1.0 Oct 30, 2002 initial release - version 0.4
MODULE-IDENTITY
.1.3.6.1.4.1.13858
vpwrDcPowerProducts
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.1
vpwrDcPowerSystem
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.2
vpwrSystemIdentGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.2.1
vpwrIdentManufacturerThe name of the DC Power manufacturer.ro
DisplayString
.1.3.6.1.4.1.13858.2.1.1
vpwrIdentModelThe DC Power Model designation.ro
DisplayString
.1.3.6.1.4.1.13858.2.1.2
vpwrIdentControllerVersionThe hardware/firmware version(s). This variable may or may not have the same value as vpwrIdentAgentSoftwareVersion.ro
DisplayString
.1.3.6.1.4.1.13858.2.1.3
vpwrIdentAgentSoftwareVersionThe SNMP agent software version. This variable may or may not have the same value as vpwrIdentControllerFirmwareVersion.ro
DisplayString
.1.3.6.1.4.1.13858.2.1.4
vpwrIdentNameA string identifying the system. This object should be set by the administrator.rw
DisplayString
.1.3.6.1.4.1.13858.2.1.5
vpwrSystemIdentTableThis table describes shelves and modules that make up the sysetm.
SEQUENCE OF VpwrSystemIdentEntry
.1.3.6.1.4.1.13858.2.1.6
vpwrSystemIdentEntryAn entry containing information applicable to a particular module making up the system.
VpwrSystemIdentEntry
.1.3.6.1.4.1.13858.2.1.6.1
vpwrShelfIndexIdentifies shelf number that this module belongs to. The possible values are 1 through 16 limited by vpwrSystemShelfCapacity. The shelf that contains the controller is identified as shelf number 1.ro
PositiveInteger
.1.3.6.1.4.1.13858.2.1.6.1.1
vpwrModuleIndexThis object identifies the module by its position in the shelf. Module numbering starts from the controller/expansion controller end of the shelf. So, the module in the first slot has an index of 1, the next module is 2 and so on. Under the current scheme - Rectifier module can have a number between 1 and 5. - LVD module starts with an index of 6.ro
PositiveInteger
.1.3.6.1.4.1.13858.2.1.6.1.2
vpwrModuleOIDIt indicates the type of the module by specifiying its OIDro
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.2.1.6.1.3
vpwrModuleParameterThe meaning of this object depends upon the module type which is indicated by vpwrModuleOID as follows - Current for Rectifier module. - Not Applicable for LVD modulero
INTEGER
.1.3.6.1.4.1.13858.2.1.6.1.4
vpwrModuleOperStatusThis object indicates current over all status of the module.ro
Enumeration
.1.3.6.1.4.1.13858.2.1.6.1.5
vpwrModuleCapacityThe meaning of this object depends upon the module type which is indicated by vpwrModuleOID as follows - Capacity for Rectifier module. - Not Applicable for LVD modulero
INTEGER
.1.3.6.1.4.1.13858.2.1.6.1.6
vpwrSystemConfigGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.2.2
vpwrSystemTempCompensationThis parameter enables/disables temperature compensation.rw
Enumeration
.1.3.6.1.4.1.13858.2.2.1
vpwrSystemTempCompStartTemperatureThe temperature at which temperature compensation becomes active.rw
INTEGER (25 .. 60) UNITS "degrees Centigrade"
.1.3.6.1.4.1.13858.2.2.2
vpwrSystemTempCompStopVoltageWhen temperature compensation is active, vpwrSystemTempCompStopVoltage is the limit to which float voltage will be reduced. For example, to set this voltage to 51.75 volts enter a value of 5175.rw
INTEGER UNITS " vpwrSystemTempCompStopVoltage *.01 Volts"
.1.3.6.1.4.1.13858.2.2.3
vpwrSystemTempCompensationSlopeThe rate at which float voltage is changed, within the specified limits, when temperature compensation is active.rw
INTEGER (0 .. 250) UNITS " milli-Volts per degrees Centigrade"
.1.3.6.1.4.1.13858.2.2.4
vpwrSystemThermalSenseTypeThis parameter selects the temperature sensing point for temperature compensation (in)activation.rw
Enumeration
.1.3.6.1.4.1.13858.2.2.5
vpwrSystemHVAlarmSetpointSystem High voltage alarm voltage setting.rw
INTEGER UNITS " vpwrSystemHVAlarmSetpoint *.01 Volts"
.1.3.6.1.4.1.13858.2.2.6
vpwrSystemBDAlarmSetpointSystem Battery Discharge voltage setting.rw
INTEGER UNITS " vpwrSystemBDAlarmSetpoint *.01 Volts"
.1.3.6.1.4.1.13858.2.2.7
vpwrSystemInternalTempLThresholdTemperature value at which temperature compensation inactive (clear) trap would be sent if temperature compensation was active when this value is reached.rw
INTEGER UNITS "degrees Centigrade"
.1.3.6.1.4.1.13858.2.2.8
vpwrSystemInternalTempUThresholdTemperature value at which temperature compensation active (set) trap would be sent.rw
INTEGER UNITS "degrees Centigrade"
.1.3.6.1.4.1.13858.2.2.9
vpwrSystemParameterGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.2.3
vpwrSystemShelfCapacityIt describes the maximum number of shelves that can/are controlled by the controller. Each shelf is uniquely numbered in the range from 1 to vpwrShelfCapacity.ro
INTEGER (1 .. 16)
.1.3.6.1.4.1.13858.2.3.1
vpwrSystemVoltageThe current system voltage.ro
INTEGER UNITS " vpwrSystemVoltage *.01 Volts"
.1.3.6.1.4.1.13858.2.3.2
vpwrSystemCurrentThe current system current.ro
INTEGER UNITS " Amperes"
.1.3.6.1.4.1.13858.2.3.3
vpwrSystemControllerStateCurrent System state as shown on the enhanced display.ro
Enumeration
.1.3.6.1.4.1.13858.2.3.4
vpwrSystemInternalTemperatureThe current controller internal temperature.ro
INTEGER UNITS "degrees Centigrade"
.1.3.6.1.4.1.13858.2.3.5
vpwrSystemTempCompensationStateActive or Inactive. Applicable only if temperature compensation is enabled. This means that the controller is temperature compensating the float voltage.ro
Enumeration
.1.3.6.1.4.1.13858.2.3.6
vpwrSystemTypeThis parameter describes the type of the system being managed. This object is set by Valere Power Inc.ro
Enumeration
.1.3.6.1.4.1.13858.2.3.7
vpwrDcPowerRectifier
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3
vpwrRectifierConfigGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.1
vpwrRectifierFVSetpointSystem Float Voltage settingrw
INTEGER UNITS " vpwrRectifierFVSetpoint *.01 Volts"
.1.3.6.1.4.1.13858.3.1.1
vpwrRectifierHVSDSetpointSystem High Voltage Shutdown voltage settingrw
INTEGER UNITS " vpwrRectifierHVSDSetpoint *.01 Volts"
.1.3.6.1.4.1.13858.3.1.2
vpwrRectifierAlarmGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.2
vpwrRectAlarmDCFail
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.2.1
vpwrRectAlarmBoostFail
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.2.2
vpwrRectAlarmACFail
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.2.3
vpwrRectAlarmHVSD
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.2.4
vpwrRectAlarmFanFail
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.2.5
vpwrRectAlarmAmbTemp
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.2.6
vpwrRectAlarmIntTemp
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.2.7
vpwrRectAlarmIShare
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.2.8
vpwrRectAlarmUV
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.2.9
vpwrRectAlarmLowVoltage
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.2.10
vpwrRectAlarmReserved
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.2.11
vpwrRectAlarmDCEnable
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.2.12
vpwrRectAlarmRemoteShutdown
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.2.13
vpwrRectAlarmModDisableShutdown
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.2.14
vpwrRectAlarmShortPinShutdown
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.2.15
vpwrRectAlarmBoostComm
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.2.16
vpwrRectifierTestGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.3.3
vpwrDcPowerLvd
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.4
vpwrLvdConfigGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.4.1
vpwrLvdWarningSetpointLVD Warning voltage setpoint.rw
INTEGER UNITS " vpwrLvdWarningSetpoint * .01 Volts"
.1.3.6.1.4.1.13858.4.1.1
vpwrLvdDisconnectSetpointLVD disconnect voltage setpoint.rw
INTEGER UNITS " vpwrLvdDisconnectSetpoint *.01 Volts"
.1.3.6.1.4.1.13858.4.1.2
vpwrLvdReconnectSetpointLVD Reconnect voltage setpoint.rw
INTEGER UNITS " vpwrLvdReconnectSetpoint *.01 Volts"
.1.3.6.1.4.1.13858.4.1.3
vpwrLvdReconnectDelayTimerThe delay time, in seconds, before LVD is reconnectedrw
INTEGER
.1.3.6.1.4.1.13858.4.1.4
vpwrLvdAlarmGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.4.2
vpwrLvdAlarmContactorOpenContactor open
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.4.2.1
vpwrLvdAlarmCBOpenCircuit Breaker open
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.4.2.2
vpwrTrapLvdFuseOpenFuse open
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.4.2.3
vpwrLvdAlarmWarningPlant Voltage below warning threshold
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.4.2.4
vpwrLvdTestGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.4.3
vpwrDcPowerTest
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.5
vpwrDcPowerModuleIdent
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.6
vpwrDcPowerBatteryGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.7
vpwrBatteryTempGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.7.1
vpwrBatteryTempTableThis table describes battery temperature probes.
SEQUENCE OF VpwrBatteryTempTableEntry
.1.3.6.1.4.1.13858.7.1.1
vpwrBatteryTempTableEntryAn entry containing information applicable to a particular temperature probe.
VpwrBatteryTempTableEntry
.1.3.6.1.4.1.13858.7.1.1.1
vpwrBatteryTempIndexIndex into temperature tablero
INTEGER
.1.3.6.1.4.1.13858.7.1.1.1.1
vpwrBatteryTempNameA string identifying probe location.rw
DisplayString
.1.3.6.1.4.1.13858.7.1.1.1.2
vpwrBatteryTempCurrent temperature as recorded by the probe.ro
INTEGER UNITS "degrees Centigrade"
.1.3.6.1.4.1.13858.7.1.1.1.3
vpwrBatteryTempLThresholdTemperature value at which a clear trap would be sent. All three battery temperature must be at or below this value to trigger this trap.rw
INTEGER UNITS "degrees Centigrade"
.1.3.6.1.4.1.13858.7.1.2
vpwrBatteryTempUThresholdTemperature value at which a set trap would be sent. Any one of the three battery temperatures at or exceeding this limit would trigger the trap.rw
INTEGER UNITS "degrees Centigrade"
.1.3.6.1.4.1.13858.7.1.3
vpwrDcPowerAlarmGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.8
vpwrAlarmsPresentThe present number of active alarm conditions.ro
Gauge32
.1.3.6.1.4.1.13858.8.1
vpwrAlarmTableA list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is initially empty at agent startup. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains. The vpwrAlarmIndex, for each type of module starts at 1 and is limited by the total number of alarams that can be generated by the module. Alarms are named by an AutonomousType (OBJECT IDENTIFIER), vpwrAlarmDescr, to allow a single table to reflect alarms for different type of modules. The number of rows in the table at any given time is reflected by the value of vpwrAlarmsPresent.
SEQUENCE OF VpwrAlarmEntry
.1.3.6.1.4.1.13858.8.2
vpwrAlarmEntryAn entry containing information applicable to a particular alarm.
VpwrAlarmEntry
.1.3.6.1.4.1.13858.8.2.1
vpwrAlarmIndexIdentifies the alarm associated with the module. It is unique on per module type basis. For example, multiple rectifiers can have the same alarm and therefore same vpwrAlarmIndex active at any one time.ro
PositiveInteger
.1.3.6.1.4.1.13858.8.2.1.1
vpwrAlarmDescrA reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition.ro
AutonomousType (SNMPv2-TC)
.1.3.6.1.4.1.13858.8.2.1.2
vpwrAlarmTimeThe value of sysUpTime when the alarm condition was detected.ro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.13858.8.2.1.3
sysAlarmConfigTableThis table describes battery temperature probes.
SEQUENCE OF SysAlarmConfigEntry
.1.3.6.1.4.1.13858.8.4
sysAlarmConfigEntryAn entry containing information applicable to a particular temperature probe.
SysAlarmConfigEntry
.1.3.6.1.4.1.13858.8.4.1
sysAlarmIndexIndex into temperature tablero
INTEGER
.1.3.6.1.4.1.13858.8.4.1.1
sysAlarmDefaultNameA string identifying probe location.ro
DisplayString
.1.3.6.1.4.1.13858.8.4.1.2
sysAlarmCustomNameA string identifying probe location.rw
DisplayString
.1.3.6.1.4.1.13858.8.4.1.3
sysAlarmSeverityAlarm Severity as denoted by Major and Minor Alarm Maskrw
Enumeration
.1.3.6.1.4.1.13858.8.4.1.4
sysAlarmToRelayMappingNo additional mapping = 0 Map to Relay A = 1 Map to Relay B = 2 Map to Relay C = 4 Map to Relay D = 8 Map to Relay E = 16 Map to Relay F = 32 Map to Relay A and B = (1 + 2) and so on The major/minor classification of alarms automatically associates it with Major/Minor relay. Assigning a null mapping here does not override sysRelayAlarmSeverity for the alarm. It should be used to define mapping to additional relays.rw
DisplayString
.1.3.6.1.4.1.13858.8.4.1.5
sysAlarmOperStatusIndicates current alarm statusro
Enumeration
.1.3.6.1.4.1.13858.8.4.1.6
vpwrDcPowerSnmpConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.9
vpwrTrapTableA list of possible trap destinations depending upon the criticality of the trap.
SEQUENCE OF VpwrTrapTableEntry
.1.3.6.1.4.1.13858.9.1
vpwrTrapTableEntryAn entry containing information applicable to a particular trap destination.
VpwrTrapTableEntry
.1.3.6.1.4.1.13858.9.1.1
vpwrTrapIpIndexTrap Entry Indexro
INTEGER
.1.3.6.1.4.1.13858.9.1.1.1
vpwrTrapIpAddressTrap destination IP Addressrw
IpAddress
.1.3.6.1.4.1.13858.9.1.1.2
vpwrTrapCriticalityCriticality of traps sent to this IP Addressrw
INTEGER
.1.3.6.1.4.1.13858.9.1.1.3
vpwrReadCommunityStringThis allows setting password to be able to do Get operationsrw
DisplayString
.1.3.6.1.4.1.13858.9.2
vpwrWriteCommunityStringThis allows setting password to be able to do Get and Set operations. The read-access is not allowed in the actual implementation.rw
DisplayString
.1.3.6.1.4.1.13858.9.3
vpwrTrapCommunityStringThis allows setting community string required for the trap to be accepted at the destination.rw
DisplayString
.1.3.6.1.4.1.13858.9.4
vpwrDcPowerTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.10
vpwrTrapPowerMajorAlarmMajor Alarm
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.1
vpwrTrapPowerMinorAlarmMinor Alarm
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.2
vpwrTrapACFAlarmAC Fail Alarm
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.3
vpwrTrapHVAlarmHigh Voltage Warning Alarm
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.4
vpwrTrapHVSDAlarmHigh Voltage Shutdown Alarm
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.5
vpwrTrapBDAlarmBattery on Discharge Alarm
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.6
vpwrTrapLVDWarningAlarmLVD Warning Alarm
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.7
vpwrTrapLVDOpenAlarmLVD Open Alarm
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.8
vpwrTrapDistAlarmDistribution Open Alarm
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.9
vpwrTrapAuxAlarmAuxiliary System Alarm
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.10
vpwrTrapSystemRedundancyAlarmSystem Redundant Capacity Alarm
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.11
vpwrTrapIShareAlarmRectifier Current Share Alarm
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.12
vpwrTrapModuleFailAlarmSingle Rectifier Fail Alarm
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.13
vpwrTrapMultipleModuleFailAlarmMultiple Rectifier Fail Alarm
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.14
vpwrTrapModuleCommAlarmModule Communication Alarm
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.15
vpwrTrapSystemOverTemperatureAlarmSystem Over Temperature Alarm
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.16
vpwrTrapSystemOKSYSTEM OK - No Active Alarms
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.17
vpwrTrapModuleInsertedA new module has been inserted into the system.
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.18
vpwrTrapModuleRemovedA module has been removed from the system.
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.19
vpwrTrapThermalCompActiveThermal compensation has become active.
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.20
vpwrTrapThermalCompInactiveThermal compensation has been de-activated.
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.21
vpwrTrapInternalTempAlarmSetInternal Temperature upper threshold exceeded.
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.22
vpwrTrapInternalTempAlarmClearedInternal Temperature within limits
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.23
vpwrTrapBatteryTempAlarmSetAt least one Battery Temperature exceeded upper threshold.
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.24
vpwrTrapBatteryTempAlarmClearedAll Battery Temperatures within limits
TRAP-TYPE
.1.3.6.1.4.1.13858.10.0.25
vpwrDcPowerTrapsMsgString
OBJECT IDENTIFIER
.1.3.6.1.4.1.13858.11
vpwrTrapsMsgStringPlace holder for trap notification message string
DisplayString
.1.3.6.1.4.1.13858.11.1
VPWR-DC-POWER-MIB - SNMP MIB Reference | MIBs Explorer