Home/Catalog/VOLIUS-OT-MIB

VOLIUS-OT-MIB

AI MIB Summary

The VOLIUS-OT-MIB enables SNMP-based monitoring and management of Volius optical transport hardware, specifically fiber optical receivers, Erbium-doped fiber amplifiers (EDFAs), optical switches, and CATV optical transmitters. It provides access to device-specific operational metrics such as optical power levels, signal-to-noise ratios, amplifier gain settings, and switch port states for fault detection and performance analysis.

This MIB describes all SNMP-enabled hardware produced by Volius, such as Fiber optical receivers, Erbium-doped fiber amplifiers, Optical switches, CATV optical transmitters.
Main OID:
vlsGlobalModule.1.3.6.1.4.1.34652.1
85
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

85 total
Object Name
volius
OBJECT IDENTIFIER
.1.3.6.1.4.1.34652
vlsGlobalModuleThis MIB describes all SNMP-enabled hardware produced by Volius, such as Fiber optical receivers, Erbium-doped fiber amplifiers, Optical switches, CATV optical transmitters.
MODULE-IDENTITY
.1.3.6.1.4.1.34652.1
vlsSystem
OBJECT IDENTIFIER
.1.3.6.1.4.1.34652.2
vlsSystemGeneral
OBJECT IDENTIFIER
.1.3.6.1.4.1.34652.2.10
vlsModelNamero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.34652.2.10.1
vlsSerialNumberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.34652.2.10.2
vlsFirmwareVersionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.34652.2.10.3
vlsBootLoaderVersionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.34652.2.10.4
vlsDateAndTimero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.34652.2.10.5
vlsTimeZoneDifference between local and UTC in minutes.rw
Integer32 (-720..780)
.1.3.6.1.4.1.34652.2.10.6
vlsCaseTemperaturero
VlsDeciCelsius
.1.3.6.1.4.1.34652.2.10.7
vlsFanSpeedro
VlsRPM
.1.3.6.1.4.1.34652.2.10.8
vlsSupplyVoltageTable
SEQUENCE OF VlsSupplyVoltageEntry
.1.3.6.1.4.1.34652.2.10.9
vlsSupplyVoltageEntry
VlsSupplyVoltageEntry
.1.3.6.1.4.1.34652.2.10.9.1
vlsSupplyVoltageIndexro
Integer32
.1.3.6.1.4.1.34652.2.10.9.1.1
vlsSupplyVoltageNominalro
VlsMillivolt
.1.3.6.1.4.1.34652.2.10.9.1.2
vlsSupplyVoltageActualro
VlsMillivolt
.1.3.6.1.4.1.34652.2.10.9.1.3
vlsNetworkServices
OBJECT IDENTIFIER
.1.3.6.1.4.1.34652.2.11
vlsNetworkAddress
OBJECT IDENTIFIER
.1.3.6.1.4.1.34652.2.11.5
vlsMacAddressrw
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.34652.2.11.5.1
vlsIpAddressrw
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.34652.2.11.5.2
vlsNetMaskrw
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.34652.2.11.5.3
vlsDefaultGatewayrw
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.34652.2.11.5.4
vlsHttp
OBJECT IDENTIFIER
.1.3.6.1.4.1.34652.2.11.6
vlsHttpPortrw
Integer32
.1.3.6.1.4.1.34652.2.11.6.1
vlsHttpEnabledrw
VlsOnOff
.1.3.6.1.4.1.34652.2.11.6.2
vlsHttpPasswordEnabledrw
VlsOnOff
.1.3.6.1.4.1.34652.2.11.6.3
vlsSnmp
OBJECT IDENTIFIER
.1.3.6.1.4.1.34652.2.11.7
vlsSnmpPortrw
Integer32
.1.3.6.1.4.1.34652.2.11.7.1
vlsTrapDestTable
SEQUENCE OF VlsTrapDestEntry
.1.3.6.1.4.1.34652.2.11.7.2
vlsTrapDestEntry
VlsTrapDestEntry
.1.3.6.1.4.1.34652.2.11.7.2.1
vlsTrapDestIndexro
Integer32
.1.3.6.1.4.1.34652.2.11.7.2.1.1
vlsTrapDestAddrrw
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.34652.2.11.7.2.1.2
vlsTrapDestPortrw
Integer32
.1.3.6.1.4.1.34652.2.11.7.2.1.3
vlsTrapDestEnablerw
VlsOnOff
.1.3.6.1.4.1.34652.2.11.7.2.1.4
vlsSntp
OBJECT IDENTIFIER
.1.3.6.1.4.1.34652.2.11.8
vlsSntpServerAddrrw
InetAddressIPv4 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.34652.2.11.8.1
vlsSntpServerPortrw
Integer32
.1.3.6.1.4.1.34652.2.11.8.2
vlsSntpEnabledrw
VlsOnOff
.1.3.6.1.4.1.34652.2.11.8.3
vlsEventLog
OBJECT IDENTIFIER
.1.3.6.1.4.1.34652.2.13
vlsLastEventCodero
VlsEvent
.1.3.6.1.4.1.34652.2.13.1
vlsLastEventIndexro
Integer32
.1.3.6.1.4.1.34652.2.13.2
vlsEventLogSizeNumber of events stored in the log.ro
Integer32
.1.3.6.1.4.1.34652.2.13.3
vlsEventLogTable
SEQUENCE OF VlsEventLogEntry
.1.3.6.1.4.1.34652.2.13.4
vlsEventLogEntry
VlsEventLogEntry
.1.3.6.1.4.1.34652.2.13.4.1
vlsEventIndexro
Integer32
.1.3.6.1.4.1.34652.2.13.4.1.1
vlsEventCodero
VlsEvent
.1.3.6.1.4.1.34652.2.13.4.1.2
vlsEventTimeStampro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.34652.2.13.4.1.3
vlsEventDateTimero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.34652.2.13.4.1.4
vlsEventMessagero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.34652.2.13.4.1.5
vlsEventTrap
NOTIFICATION-TYPE
.1.3.6.1.4.1.34652.2.13.8
vlsAlarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.34652.2.14
vlsAlarmsActiveMaskThis is a bit mask where all active alarms are combined. Alarms are latching, that is an alarm is still active even when the condition activating the alarm no longer exists.ro
Integer32
.1.3.6.1.4.1.34652.2.14.1
vlsAlarmsResetMaskYou can write reset mask to reset individual alarms. An alarm will be reset only if the activating condition no longer exists.rw
Integer32
.1.3.6.1.4.1.34652.2.14.2
vlsAlarmsTable
SEQUENCE OF VlsAlarmsEntry
.1.3.6.1.4.1.34652.2.14.3
vlsAlarmsEntry
VlsAlarmsEntry
.1.3.6.1.4.1.34652.2.14.3.1
vlsAlarmIndexro
Integer32
.1.3.6.1.4.1.34652.2.14.3.1.1
vlsAlarmStateWhen read, this OID indicates if the alarm is active. When vlsOff is written to this OID, the alarm is reset.rw
VlsOnOff
.1.3.6.1.4.1.34652.2.14.3.1.2
vlsAlarmMessagero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.34652.2.14.3.1.3
vlsEdfa
OBJECT IDENTIFIER
.1.3.6.1.4.1.34652.3
vlsOpticalSwitch
OBJECT IDENTIFIER
.1.3.6.1.4.1.34652.4
vlsCatvTransmitter
OBJECT IDENTIFIER
.1.3.6.1.4.1.34652.5
vlsTxEmissionStateReports whether the laser is on or off.ro
VlsOnOff
.1.3.6.1.4.1.34652.5.1
vlsTxOutputTable
SEQUENCE OF VlsTxOutputEntry
.1.3.6.1.4.1.34652.5.2
vlsTxOutputEntry
VlsTxOutputEntry
.1.3.6.1.4.1.34652.5.2.1
vlsTxOutputIndexOptical output number (1 or 2).ro
Integer32
.1.3.6.1.4.1.34652.5.2.1.1
vlsTxOutputPowerOptical output level.ro
VlsDeciDbm
.1.3.6.1.4.1.34652.5.2.1.2
vlsTxPoutLowAlarmOutput power low alarm threshold.rw
VlsDeciDbm
.1.3.6.1.4.1.34652.5.3
vlsTxPoutHighAlarmOutput power high alarm threshold.rw
VlsDeciDbm
.1.3.6.1.4.1.34652.5.4
vlsTxInputCompositeComposite RF level at the transmitter input.ro
VlsDbm
.1.3.6.1.4.1.34652.5.5
vlsTxInputPerChannelPer-channel RF level at the transmitter input.ro
VlsDbuv
.1.3.6.1.4.1.34652.5.6
vlsTxChannelPwrFactorThis factor is used to convert composite RF level to per-channel RF level. The factor is expressed in units of 0.1 dB and is always negative or zero. For example, if the channel plan is 100 channels all with the same RF level, the factor should be -200 (meaning -20.0 dB). Then, if composite RF level is 0 dBm (that is 108.75 dBuV), per-channel RF level would be 108.75 - 20 = 88.75 dBuV.rw
VlsDeciDb
.1.3.6.1.4.1.34652.5.7
vlsTxOmiComposite OMI in units of 0.1%.ro
VlsPerMille
.1.3.6.1.4.1.34652.5.8
vlsTxAttActual variable attenuator state. The range is 0..25 dB.ro
VlsDeciDb
.1.3.6.1.4.1.34652.5.9
vlsTxLaserCurrentLaser current. 100% corresponds to the current set during factory calibration. The current is expected to rise slowly after years of operation (laser aging).ro
VlsPercent
.1.3.6.1.4.1.34652.5.10
vlsTxLaserTecCurrentro
VlsPercent
.1.3.6.1.4.1.34652.5.11
vlsTxLaserPowerro
VlsDeciDbm
.1.3.6.1.4.1.34652.5.12
vlsTxLaserTemperaturero
VlsDeciCelsius
.1.3.6.1.4.1.34652.5.13
vlsTxAgcAGC mode on/off control.rw
VlsOnOff
.1.3.6.1.4.1.34652.5.14
vlsTxSetOmiOMI setpoint when AGC is on.rw
VlsPerMille
.1.3.6.1.4.1.34652.5.15
vlsTxSetAttVariable attenuator setpoint when AGC is off.rw
VlsDeciDb
.1.3.6.1.4.1.34652.5.16
vlsTxSetSbsThresholdSBS suppression level.rw
VlsDbm
.1.3.6.1.4.1.34652.5.17
vlsOpticalReceiver
OBJECT IDENTIFIER
.1.3.6.1.4.1.34652.6
vlsCabinetMonitor
OBJECT IDENTIFIER
.1.3.6.1.4.1.34652.7
vlsUpsMonitor
OBJECT IDENTIFIER
.1.3.6.1.4.1.34652.8
VOLIUS-OT-MIB - SNMP MIB Reference | MIBs Explorer