Home/Catalog/VMWARE-VRNI-MIB

VMWARE-VRNI-MIB

AI MIB Summary

The VMWARE-VRNI-MIB module enables SNMP-based monitoring of VMware vRealize Network Insight telemetry, specifically exposing virtual network topology, flow statistics, and security policy enforcement states for NSX and vSphere environments. This MIB facilitates the collection of granular metrics regarding virtual switch performance, distributed firewall rule utilization, and logical network path analysis to support capacity planning and anomaly detection.

This MIB module is for VMware vRealize Network Insight as described here: https://www.vmware.com/support/pubs/vrealize-network-insight-pubs.html
Main OID:
vmwNetworkInsightMIB.1.3.6.1.4.1.6876.100.1
170
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

170 total
Object Name
vmwNetworkInsightMIB
MODULE-IDENTITY
.1.3.6.1.4.1.6876.100.1
vmwVRNIEvents
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.100.1.0
vmwSnmpTrapsAreConfigured
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.101
vmwSnmpTrapsAreDisabled
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.102
vmwTestTrap
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.103
vmwEntityDiscoveryChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20001
vmwEntityPropertiesChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20002
vmwFirewallNotInstalledOnHostEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20003
vmwHostWithStaleFirewallRulesEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20004
vmwIpAddressChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20005
vmwL2GatewayAnomalyEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20006
vmwL2NetworkAddressAnomalyEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20007
vmwL2NetworkDiameterExceededEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20008
vmwL2NetworkUplinkMissingEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20009
vmwL2NetworkWithNoVMsEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20010
vmwLayer2NetworkDiameterChangedEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20011
vmwMTUMismatchEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20012
vmwNetworkIsolationEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20013
vmwNoPathEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20014
vmwSpoofguardDisabledEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20015
vmwVMotionEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20018
vmwVMWithDisconnectedVnicsEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20019
vmwVMWithMulipleVnicsOnDifferentVxlansEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20020
vmwVMWithMulipleVnicsOnSameL2Event
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20021
vmwVMWithNoIpAddressEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20022
vmwVTEPMissingEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20023
vmwL2Event
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20024
vmwMembershipChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20025
vmwSecurityGroupMembershipChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20026
vmwFirewallRuleMembershipChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20027
vmwVlanMembershipChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20028
vmwVxlanMembershipChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20029
vmwDeleteChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20030
vmwVtepFailedPingEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20031
vmwEmptySearchStreamChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20034
vmwSearchStreamMembershipChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20035
vmwEmptySearchStreamProblemEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20036
vmwSearchStreamMembershipProblemEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20037
vmwOspfConfigurationMismatchEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20038
vmwServiceVMNotHealthyEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20039
vmwServiceVMNotPoweredOnEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20040
vmwServiceVMHighCPUUsageEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20041
vmwServiceVMHighMemoryUsageEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20042
vmwServiceVMHighDiskUsageEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20043
vmwIPSetPropertiesChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20050
vmwFirewallRulePropertiesChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20051
vmwSecurityGroupPropertiesChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20052
vmwIPSetMembershipChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20053
vmwFirewallRuleMaskEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20054
vmwSecurityMembershipChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20056
vmwSecurityTagPropertiesChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20057
vmwSecurityTagMembershipChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20058
vmwHostDatastoreChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20059
vmwVMDatastoreChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20060
vmwVMSnapshotChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20061
vmwVMVirtualDiskChangeEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20062
vmwIPSetDefinitionMismatchEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20063
vmwSegmentMismatchEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20064
vmwVtepEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20065
vmwVtepConfigurationFaultEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20066
vmwDLRNetworksNotReachableEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20067
vmwVtepSubnetMismatchEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20068
vmwVtepCountMismatchEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20069
vmwEdgeNetworksNotReachableEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.20070
vmwThresholdExceededEventCpuReady
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30001
vmwThresholdExceededEventCpuCoStop
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30002
vmwThresholdExceededEventDiskCommandAbortRule
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30003
vmwThresholdExceededEventIODeviceLatencyRule
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30004
vmwThresholdExceededEventIOKernelLatencyRule
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30005
vmwThresholdExceededEventMemorySwapInRule
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30006
vmwThresholdExceededEventMemorySwapOutRule
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30007
vmwThresholdExceededEventNetworkRxDropRule
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30008
vmwThresholdExceededEventNetworkTxDropRule
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30009
vmwPacketDropEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30100
vmwSwitchPortPacketDropEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30101
vmwRouterInterfacePacketDropEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30102
vmwVnicPacketDropEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30103
vmwVTEPUnderlayPacketDropEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30104
vmwPnicUnderlyingSwitchPortPacketDropEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30105
vmwDevicePacketDropEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30106
vmwThresholdExceededEventDatastoreFreeSpaceWarning
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30203
vmwThresholdExceededEventDatastoreFreeSpaceCritical
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30204
vmwThresholdExceededEventDatastoreReadLatency
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30205
vmwThresholdExceededEventDatastoreWriteLatency
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.30206
vmwDistributedFirewallApplyHostEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.35001
vmwDistributedFirewallApplyVMEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.35002
vmwNsxEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.35003
vmwFeatureImpactedEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.35004
vmwNSXComponentEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.35221
vmwNSXBackupEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.35222
vmwNSXBackupAuditLogExcludedEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.35223
vmwNSXUnsecureBackupEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.35224
vmwNSXBackupSystemEventsExcludedEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.35225
vmwNSXBackupNotScheduledEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.35226
vmwNSXBackupNotRecordedEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.35227
vmwNSXNtpServerEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.35228
vmwNSXSysLogServerEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.35229
vmwControllerSysLogServerEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.35230
vmwClusterFeatureVersionMismatchEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.36022
vmwHostFeatureVersionMismatchEvent
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.100.1.0.36023
Showing 100 of 170 OID objects

VMWARE-VRNI-MIB Technical Reference Overview

The VMWARE-VRNI-MIB SNMP MIB module published by VMware defines 170 managed OID objects, including 12 scalar/column metrics, 0 SNMP tables, and 152 trap/notification events anchored at base OID .1.3.6.1.4.1.6876.100.1. Monitored SNMP traps/notifications include vmwApplyRuleToVnicFailedEvent, vmwClusterFeatureVersionMismatchEvent, vmwClusterHostsVtepMTUMismatchEvent, vmwConfigUpdateOnHostFailedEvent, vmwContainerConfigUpdateOnVnicFailedEvent, vmwControllerSysLogServerEvent.

Key OID Definitions in VMWARE-VRNI-MIB

vmwNetworkInsightMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.6876.100.1

This MIB module is for VMware vRealize Network Insight as described here: https://www.vmware.com/support/pubs/vrealize-network-insight-pubs.html

vmwApplyRuleToVnicFailedEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.70005

Apply Rule To Vnic Failed Event

vmwClusterFeatureVersionMismatchEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.36022

Cluster Feature Mismatch Event

vmwClusterHostsVtepMTUMismatchEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.36030

Host Vtep Mtu Mismatch Event

vmwConfigUpdateOnHostFailedEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.70003

Config Update On Host Failed Event

vmwContainerConfigUpdateOnVnicFailedEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.70006

Container Config Update On Vnic Failed Event

vmwControllerSysLogServerEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.35230

Syslog Server not configured

vmwDLRNetworksNotReachableEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.20067

DLR Routing event

vmwDeleteChangeEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.20030

Delete Event

vmwDevicePacketDropEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.30106

Device Packet Drop

vmwDistributedFirewallApplyHostEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.35001

Distributed Firewall Apply Host Event

vmwDistributedFirewallApplyVMEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.35002

Distributed Firewall Apply VM Event

vmwEcmpIsEnabledAndStatefulServicesAreUpEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.36054

NSX Edge Running with both ECMP and Stateful Edge Services Event

vmwEdgeHANotConfiguredEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.36032

NSX Edge High Availability is not enabled Event

vmwEdgeInterfacesDownEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.36033

One or More NSX Edge Interfaces are down Event

vmwEdgeMissingInterfaceOSPFAreaMappingEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.36056

NSX Edge Interface to OSPF Area Mapping Missing Event

vmwEdgeNetworksNotReachableEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.20070

Edge Routing event

vmwEdgeNotDeployedEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.36053

NSX Edge not deployed Event

vmwEdgeNotHAEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.36052

NSX Edge not Highly Available Event

vmwEdgeUnhealthyEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.70013

Edge Health Event

vmwEdgeVMCommunicationFailureEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.70014

Edge communication failure Event

vmwEdgeVMNotRespondingEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.70012

Edge VM Responding Event

vmwEmptySearchStreamChangeEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.20034

Search with no results

vmwEmptySearchStreamProblemEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.100.1.0.20036

Search with no results (Problem)

More MIBs from VMware

Browse all VMwareMIBs →
LSERIES-TAPE-LIBRARY-MIB

Standard SNMP MIB module defining data structures for LSERIES-TAPE-LIBRARY-MIB.

387 objects→
VMWARE-NSX-MANAGER-MIB

The VMWARE-NSX-MANAGER-MIB module defines the structure for SNMP traps generated by the VMware NSX Manager virtual appliance to report critical state changes and events for software-defined networking components, including logical switches, edge services gateways, and controllers. This module enables network management systems to parse and correlate specific operational alerts and fault notifications from the NSX Manager within a vSphere environment.

277 objects→
VELOCLOUD-EDGE-MIB

SNMP MIB module

111 objects→
VMWARE-VCOPS-EVENT-MIB

The VMWARE-VCOPS-EVENT-MIB defines the structure for SNMP traps generated by VMware vCenter Operations Manager to report infrastructure health events, including performance thresholds, capacity warnings, and system anomalies. This module enables external monitoring systems to parse and correlate specific operational alerts from the vCenter Operations Manager environment.

72 objects→
VMWARE-VMINFO-MIB

The VMWARE-VMINFO-MIB enables SNMP-based polling and event notification for VMware ESXi host inventory and virtual machine state transitions, mapping specific managed objects to VMware VIM API properties. This module facilitates the collection of critical VM metrics including power status, resource allocation, and host association data for centralized infrastructure monitoring.

59 objects→
VMWARE-ENV-MIB

The VMWARE-ENV-MIB module exposes IPMI-defined hardware component status and environmental telemetry, including temperature, voltage, fan speed, and power supply states, for VMware ESXi hosts. It enables centralized monitoring of physical infrastructure health by mapping these low-level sensor readings to standard SNMP objects for alerting and capacity planning.

57 objects→