VMWARE-VRNI-MIB
The VMWARE-VRNI-MIB module enables SNMP-based monitoring of VMware vRealize Network Insight telemetry, specifically exposing virtual network topology, flow statistics, and security policy enforcement states for NSX and vSphere environments. This MIB facilitates the collection of granular metrics regarding virtual switch performance, distributed firewall rule utilization, and logical network path analysis to support capacity planning and anomaly detection.
Imported Objects
Objects
170 total| Object Name |
|---|
vmwNetworkInsightMIB MODULE-IDENTITY .1.3.6.1.4.1.6876.100.1 |
vmwVRNIEvents OBJECT IDENTIFIER .1.3.6.1.4.1.6876.100.1.0 |
vmwSnmpTrapsAreConfigured NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.101 |
vmwSnmpTrapsAreDisabled NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.102 |
vmwTestTrap NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.103 |
vmwEntityDiscoveryChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20001 |
vmwEntityPropertiesChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20002 |
vmwFirewallNotInstalledOnHostEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20003 |
vmwHostWithStaleFirewallRulesEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20004 |
vmwIpAddressChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20005 |
vmwL2GatewayAnomalyEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20006 |
vmwL2NetworkAddressAnomalyEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20007 |
vmwL2NetworkDiameterExceededEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20008 |
vmwL2NetworkUplinkMissingEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20009 |
vmwL2NetworkWithNoVMsEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20010 |
vmwLayer2NetworkDiameterChangedEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20011 |
vmwMTUMismatchEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20012 |
vmwNetworkIsolationEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20013 |
vmwNoPathEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20014 |
vmwSpoofguardDisabledEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20015 |
vmwVMotionEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20018 |
vmwVMWithDisconnectedVnicsEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20019 |
vmwVMWithMulipleVnicsOnDifferentVxlansEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20020 |
vmwVMWithMulipleVnicsOnSameL2Event NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20021 |
vmwVMWithNoIpAddressEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20022 |
vmwVTEPMissingEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20023 |
vmwL2Event NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20024 |
vmwMembershipChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20025 |
vmwSecurityGroupMembershipChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20026 |
vmwFirewallRuleMembershipChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20027 |
vmwVlanMembershipChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20028 |
vmwVxlanMembershipChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20029 |
vmwDeleteChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20030 |
vmwVtepFailedPingEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20031 |
vmwEmptySearchStreamChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20034 |
vmwSearchStreamMembershipChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20035 |
vmwEmptySearchStreamProblemEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20036 |
vmwSearchStreamMembershipProblemEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20037 |
vmwOspfConfigurationMismatchEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20038 |
vmwServiceVMNotHealthyEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20039 |
vmwServiceVMNotPoweredOnEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20040 |
vmwServiceVMHighCPUUsageEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20041 |
vmwServiceVMHighMemoryUsageEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20042 |
vmwServiceVMHighDiskUsageEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20043 |
vmwIPSetPropertiesChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20050 |
vmwFirewallRulePropertiesChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20051 |
vmwSecurityGroupPropertiesChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20052 |
vmwIPSetMembershipChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20053 |
vmwFirewallRuleMaskEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20054 |
vmwSecurityMembershipChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20056 |
vmwSecurityTagPropertiesChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20057 |
vmwSecurityTagMembershipChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20058 |
vmwHostDatastoreChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20059 |
vmwVMDatastoreChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20060 |
vmwVMSnapshotChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20061 |
vmwVMVirtualDiskChangeEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20062 |
vmwIPSetDefinitionMismatchEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20063 |
vmwSegmentMismatchEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20064 |
vmwVtepEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20065 |
vmwVtepConfigurationFaultEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20066 |
vmwDLRNetworksNotReachableEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20067 |
vmwVtepSubnetMismatchEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20068 |
vmwVtepCountMismatchEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20069 |
vmwEdgeNetworksNotReachableEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.20070 |
vmwThresholdExceededEventCpuReady NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30001 |
vmwThresholdExceededEventCpuCoStop NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30002 |
vmwThresholdExceededEventDiskCommandAbortRule NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30003 |
vmwThresholdExceededEventIODeviceLatencyRule NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30004 |
vmwThresholdExceededEventIOKernelLatencyRule NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30005 |
vmwThresholdExceededEventMemorySwapInRule NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30006 |
vmwThresholdExceededEventMemorySwapOutRule NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30007 |
vmwThresholdExceededEventNetworkRxDropRule NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30008 |
vmwThresholdExceededEventNetworkTxDropRule NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30009 |
vmwPacketDropEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30100 |
vmwSwitchPortPacketDropEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30101 |
vmwRouterInterfacePacketDropEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30102 |
vmwVnicPacketDropEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30103 |
vmwVTEPUnderlayPacketDropEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30104 |
vmwPnicUnderlyingSwitchPortPacketDropEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30105 |
vmwDevicePacketDropEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30106 |
vmwThresholdExceededEventDatastoreFreeSpaceWarning NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30203 |
vmwThresholdExceededEventDatastoreFreeSpaceCritical NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30204 |
vmwThresholdExceededEventDatastoreReadLatency NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30205 |
vmwThresholdExceededEventDatastoreWriteLatency NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.30206 |
vmwDistributedFirewallApplyHostEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.35001 |
vmwDistributedFirewallApplyVMEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.35002 |
vmwNsxEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.35003 |
vmwFeatureImpactedEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.35004 |
vmwNSXComponentEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.35221 |
vmwNSXBackupEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.35222 |
vmwNSXBackupAuditLogExcludedEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.35223 |
vmwNSXUnsecureBackupEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.35224 |
vmwNSXBackupSystemEventsExcludedEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.35225 |
vmwNSXBackupNotScheduledEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.35226 |
vmwNSXBackupNotRecordedEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.35227 |
vmwNSXNtpServerEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.35228 |
vmwNSXSysLogServerEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.35229 |
vmwControllerSysLogServerEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.35230 |
vmwClusterFeatureVersionMismatchEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.36022 |
vmwHostFeatureVersionMismatchEvent NOTIFICATION-TYPE .1.3.6.1.4.1.6876.100.1.0.36023 |
VMWARE-VRNI-MIB Technical Reference Overview
The VMWARE-VRNI-MIB SNMP MIB module published by VMware defines 170 managed OID objects, including 12 scalar/column metrics, 0 SNMP tables, and 152 trap/notification events anchored at base OID .1.3.6.1.4.1.6876.100.1. Monitored SNMP traps/notifications include vmwApplyRuleToVnicFailedEvent, vmwClusterFeatureVersionMismatchEvent, vmwClusterHostsVtepMTUMismatchEvent, vmwConfigUpdateOnHostFailedEvent, vmwContainerConfigUpdateOnVnicFailedEvent, vmwControllerSysLogServerEvent.
Key OID Definitions in VMWARE-VRNI-MIB
.1.3.6.1.4.1.6876.100.1This MIB module is for VMware vRealize Network Insight as described here: https://www.vmware.com/support/pubs/vrealize-network-insight-pubs.html
.1.3.6.1.4.1.6876.100.1.0.70005Apply Rule To Vnic Failed Event
.1.3.6.1.4.1.6876.100.1.0.36022Cluster Feature Mismatch Event
.1.3.6.1.4.1.6876.100.1.0.36030Host Vtep Mtu Mismatch Event
.1.3.6.1.4.1.6876.100.1.0.70003Config Update On Host Failed Event
.1.3.6.1.4.1.6876.100.1.0.70006Container Config Update On Vnic Failed Event
.1.3.6.1.4.1.6876.100.1.0.35230Syslog Server not configured
.1.3.6.1.4.1.6876.100.1.0.20067DLR Routing event
.1.3.6.1.4.1.6876.100.1.0.20030Delete Event
.1.3.6.1.4.1.6876.100.1.0.30106Device Packet Drop
.1.3.6.1.4.1.6876.100.1.0.35001Distributed Firewall Apply Host Event
.1.3.6.1.4.1.6876.100.1.0.35002Distributed Firewall Apply VM Event
.1.3.6.1.4.1.6876.100.1.0.36054NSX Edge Running with both ECMP and Stateful Edge Services Event
.1.3.6.1.4.1.6876.100.1.0.36032NSX Edge High Availability is not enabled Event
.1.3.6.1.4.1.6876.100.1.0.36033One or More NSX Edge Interfaces are down Event
.1.3.6.1.4.1.6876.100.1.0.36056NSX Edge Interface to OSPF Area Mapping Missing Event
.1.3.6.1.4.1.6876.100.1.0.20070Edge Routing event
.1.3.6.1.4.1.6876.100.1.0.36053NSX Edge not deployed Event
.1.3.6.1.4.1.6876.100.1.0.36052NSX Edge not Highly Available Event
.1.3.6.1.4.1.6876.100.1.0.70013Edge Health Event
.1.3.6.1.4.1.6876.100.1.0.70014Edge communication failure Event
.1.3.6.1.4.1.6876.100.1.0.70012Edge VM Responding Event
.1.3.6.1.4.1.6876.100.1.0.20034Search with no results
.1.3.6.1.4.1.6876.100.1.0.20036Search with no results (Problem)
More MIBs from VMware
Browse all VMwareMIBs →Standard SNMP MIB module defining data structures for LSERIES-TAPE-LIBRARY-MIB.
The VMWARE-NSX-MANAGER-MIB module defines the structure for SNMP traps generated by the VMware NSX Manager virtual appliance to report critical state changes and events for software-defined networking components, including logical switches, edge services gateways, and controllers. This module enables network management systems to parse and correlate specific operational alerts and fault notifications from the NSX Manager within a vSphere environment.
SNMP MIB module
The VMWARE-VCOPS-EVENT-MIB defines the structure for SNMP traps generated by VMware vCenter Operations Manager to report infrastructure health events, including performance thresholds, capacity warnings, and system anomalies. This module enables external monitoring systems to parse and correlate specific operational alerts from the vCenter Operations Manager environment.
The VMWARE-VMINFO-MIB enables SNMP-based polling and event notification for VMware ESXi host inventory and virtual machine state transitions, mapping specific managed objects to VMware VIM API properties. This module facilitates the collection of critical VM metrics including power status, resource allocation, and host association data for centralized infrastructure monitoring.
The VMWARE-ENV-MIB module exposes IPMI-defined hardware component status and environmental telemetry, including temperature, voltage, fan speed, and power supply states, for VMware ESXi hosts. It enables centralized monitoring of physical infrastructure health by mapping these low-level sensor readings to standard SNMP objects for alerting and capacity planning.