Home/Catalog/VMWARE-NSX-MANAGER-MIB

VMWARE-NSX-MANAGER-MIB

AI MIB Summary

The VMWARE-NSX-MANAGER-MIB module defines the structure for SNMP traps generated by the VMware NSX Manager virtual appliance to report critical state changes and events for software-defined networking components, including logical switches, edge services gateways, and controllers. This module enables network management systems to parse and correlate specific operational alerts and fault notifications from the NSX Manager within a vSphere environment.

This MIB file contains the information that the receiving party needs in order to interpret SNMP traps sent by NSX Manager. VMware NSX for vSphere is a key product in the SDDC architecture. With NSX, virtualization delivers for networking what it has already delivered for compute and storage. In much the same way that server virtualization programmatically creates, snapshots, deletes and restores software-based virtual machines (VMs), NSX network virtualization programmatically creates, snapshots, deletes, and restores software-based virtual networks. The result is a completely transformative approach to networking that not only enables data center managers to achieve orders of magnitude better agility and economics, but also allows for a vastly simplified operational model for the underlying physical network. With the ability to be deployed on any IP network, including both existing traditional networking models and next-generation fabric architectures from any vendor, NSX is a completely non-disruptive solution. In fact, with NSX, the physical network infrastructure you already have is all you need to deploy a software-defined data center. The NSX Manager provides the graphical user interface (GUI) and the REST APIs for creating, configuring, and monitoring NSX components, such as controllers, logical switches, and edge services gateways. The NSX Manager provides an aggregated system view and is the centralized network management component of NSX. NSX Manager is installed as a virtual appliance on any ESX host in your vCenter environment. Support requests can be filed with VMware using KB article: http://kb.vmware.com/kb/2006985 To reach NSX Manager Service Composer UI, login to vSphere UI(https://<vsphere-ip>)->Networking & Security->Service Composer
Main OID:
vmwNsxManagerMIB.1.3.6.1.4.1.6876.90.1
276
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

276 total
Object Name
vmwNsxManagerMIB
MODULE-IDENTITY
.1.3.6.1.4.1.6876.90.1
vmwNsxMAlertData
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.90.1.1
vmwNsxMEventCodero
Integer32
.1.3.6.1.4.1.6876.90.1.1.1
vmwNsxMEventTimestampro
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.6876.90.1.1.2
vmwNsxMEventMessagero
OCTET STRING
.1.3.6.1.4.1.6876.90.1.1.3
vmwNsxMEventSeverityro
VmwNsxManagerTypeSeverity
.1.3.6.1.4.1.6876.90.1.1.4
vmwNsxMEventComponentro
OCTET STRING
.1.3.6.1.4.1.6876.90.1.1.5
vmwNsxMUuidro
UUID (UUID-TC-MIB)
.1.3.6.1.4.1.6876.90.1.1.6
vmwNsxMCountro
Integer32
.1.3.6.1.4.1.6876.90.1.1.7
vmwNsxMNotification
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.90.1.2
vmwNsxMBranch
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.90.1.2.0
vmwNsxMGroupsBranch
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.90.1.2.0.1
vmwNsxMGroupsPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.90.1.2.0.1.0
vmwNsxMConfigGroup
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.0.1.0.1
vmwNsxMSnmp
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.90.1.2.1
vmwNsxMSnmpPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.90.1.2.1.0
vmwNsxMSnmpDisabled
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.1.0.1
vmwNsxMSnmpManagerConfigUpdated
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.1.0.2
vmwNsxMSecurity
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.90.1.2.2
vmwNsxMSecurityPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.90.1.2.2.0
vmwNsxMIpAddedBlackList
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.2.0.1
vmwNsxMIpRemovedBlackList
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.2.0.2
vmwNsxMSsoConfigFailure
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.2.0.3
vmwNsxMSsoUnconfigured
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.2.0.4
vmwNsxMUserRoleAssigned
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.2.0.5
vmwNsxMUserRoleUnassigned
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.2.0.6
vmwNsxMGroupRoleAssigned
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.2.0.7
vmwNsxMGroupRoleUnassigned
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.2.0.8
vmwNsxMVcLoginFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.2.0.9
vmwNsxMVcDisconnected
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.2.0.10
vmwNsxMLostVcConnectivity
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.2.0.11
vmwNsxMSsoDisconnected
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.2.0.12
vmwNsxMFirewall
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.90.1.2.3
vmwNsxMFirewallPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.90.1.2.3.0
vmwNsxMFltrCnfgUpdateFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.1
vmwNsxMFltrCnfgNotAppliedToVnic
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.2
vmwNsxMFltrCnfgAppliedToVnic
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.3
vmwNsxMFltrCreatedForVnic
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.4
vmwNsxMFltrDeletedForVnic
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.5
vmwNsxMFirewallConfigUpdateFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.6
vmwNsxMFirewallRuleFailedVnic
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.7
vmwNsxMFirewallRuleAppliedVnic
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.8
vmwNsxMCntnrCnfgUpdateFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.9
vmwNsxMFlowMissed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.10
vmwNsxMSpoofGuardCnfgUpdateFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.11
vmwNsxMSpoofGuardFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.12
vmwNsxMSpoofGuardApplied
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.13
vmwNsxMSpoofGuardDisableFail
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.14
vmwNsxMSpoofGuardDisabled
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.15
vmwNsxMLegacyAppServiceDeletionFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.16
vmwNsxMFirewallCpuThresholdCrossed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.17
vmwNsxMFirewallMemThresholdCrossed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.18
vmwNsxMConnPerSecThrshldCrossed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.19
vmwNsxMFirewallCnfgUpdateTimedOut
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.20
vmwNsxMSpoofGuardCnfgUpdateTmOut
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.21
vmwNsxMFirewallPublishFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.22
vmwNsxMCntnrUpdatePublishFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.23
vmwNsxMSpoofGuardUpdatePublishFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.24
vmwNsxMExcludeListPublishFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.25
vmwNsxMFirewallCnfgUpdateOnDltCntnr
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.26
vmwNsxMHostSyncFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.27
vmwNsxMHostSynced
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.28
vmwNsxMFirewallInstalled
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.29
vmwNsxMFirewallInstallFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.30
vmwNsxMFirewallClusterInstalled
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.31
vmwNsxMFirewallClusterUninstalled
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.32
vmwNsxMFirewallClusterDisabled
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.33
vmwNsxMFirewallForceSyncClusterFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.34
vmwNsxMFirewallForceSyncClusterSuccess
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.35
vmwNsxMFirewallVsfwdProcessStarted
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.3.0.36
vmwNsxMEdge
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.90.1.2.4
vmwNsxMEdgePrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.90.1.2.4.0
vmwNsxMEdgeNoVmServing
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.1
vmwNsxMEdgeGatewayCreated
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.2
vmwNsxMEdgeVmBadState
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.3
vmwNsxMEdgeVmCommFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.4
vmwNsxMEdgeVmCnfgChanged
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.5
vmwNsxMEdgeGatewayDeleted
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.6
vmwNsxMEdgeGatewayReDeployed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.7
vmwNsxMEdgeVmPowerOff
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.8
vmwNsxMEdgeApplianceSizeChanged
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.9
vmwNsxMEdgeUpgrade51x
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.10
vmwNsxMEdgeLicenseChanged
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.11
vmwNsxMEdgeApplianceMoved
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.12
vmwNsxMEdgeApplianceNotFound
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.13
vmwNsxMEdgeVMHealthCheckMiss
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.14
vmwNsxMEdgeHealthCheckMiss
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.15
vmwNsxMEdgeCommAgentNotConnected
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.16
vmwNsxMApplianceWithDifferentId
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.17
vmwNsxMFirewallRuleModified
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.18
vmwNsxMEdgeAntiAffinityRuleViolated
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.19
vmwNsxMEdgeHaEnabled
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.20
vmwNsxMEdgeHaDisabled
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.21
vmwNsxMEdgeGatewayRecovered
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.22
vmwNsxMEdgeVmRecovered
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.23
vmwNsxMEdgeGatewayUpgraded
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.24
vmwNsxMEdgeVmHlthChkDisabled
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.25
vmwNsxMEdgePrePublishFailed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.26
vmwNsxMEdgeForcedSync
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.27
vmwNsxMEdgeVmBooted
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.90.1.2.4.0.28
Showing 100 of 276 OID objects

VMWARE-NSX-MANAGER-MIB Technical Reference Overview

The VMWARE-NSX-MANAGER-MIB SNMP MIB module published by VMware defines 276 managed OID objects, including 10 scalar/column metrics, 0 SNMP tables, and 217 trap/notification events anchored at base OID .1.3.6.1.4.1.6876.90.1. Monitored SNMP traps/notifications include vmwNsxMApplianceWithDifferentId, vmwNsxMBackingPortgroupMissing, vmwNsxMBackingPortgroupReappears, vmwNsxMCntnrCnfgUpdateFailed, vmwNsxMCntnrUpdatePublishFailed, vmwNsxMConfigGroup.

Key OID Definitions in VMWARE-NSX-MANAGER-MIB

vmwNsxManagerMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.6876.90.1

This MIB file contains the information that the receiving party needs in order to interpret SNMP traps sent by NSX Manager. VMware NSX for vSphere is a key product in the SDDC architecture. With NSX, virtualization delivers for networking what it has already delivered for compute and storage. In much the same way that server virtualization programmatically creates, snapshots, deletes and restores software-based virtual machines (VMs), NSX network virtualization programmatically creates, snapshots, deletes, and restores software-based virtual networks. The result is a completely transformative approach to networking that not only enables data center managers to achieve orders of magnitude better agility and economics, but also allows for a vastly simplified operational model for the underlying physical network. With the ability to be deployed on any IP network, including both existing traditional networking models and next-generation fabric architectures from any vendor, NSX is a completely non-disruptive solution. In fact, with NSX, the physical network infrastructure you already have is all you need to deploy a software-defined data center. The NSX Manager provides the graphical user interface (GUI) and the REST APIs for creating, configuring, and monitoring NSX components, such as controllers, logical switches, and edge services gateways. The NSX Manager provides an aggregated system view and is the centralized network management component of NSX. NSX Manager is installed as a virtual appliance on any ESX host in your vCenter environment. Support requests can be filed with VMware using KB article: http://kb.vmware.com/kb/2006985 To reach NSX Manager Service Composer UI, login to vSphere UI(https://<vsphere-ip>)->Networking & Security->Service Composer

vmwNsxMApplianceWithDifferentIdNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.4.0.17

A notification generated when Edge VM is discovered with a different vmId. Action required: None

vmwNsxMBackingPortgroupMissingNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.20.0.19

NSX manager detected one backing portgroup of a logical switch is missing on VCenter. Action required: Click on the resolve button on UI or call the API (POST https://<nsx-manager-host>/api/2.0/vdn/virtualwires/<virtualwireId>/backing?action=remediate) to recreate that backing portgroup. Frequency of traps: Whenever logical switch backing portgroup is missing on VC. Affects: VMs cannot be connected to this Logical Switch.

vmwNsxMBackingPortgroupReappearsNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.20.0.20

NSX manager detected one backing portgroup of a logical switch that was missing reappears on VC. Action required: None Frequency of traps: Whenever user triggered remediate API on Logical Switch which has missing backing portgroup.

vmwNsxMCntnrCnfgUpdateFailedNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.3.0.9

Failed receive, parse or update the container configuration. Contextual data provided with this event may indicate the cause of this failure. Collect error logs (vmkernel.log) when firewall configuration was applied to the vnic. Verify that vsip kernel heaps have enough free memory. Check VSFWD logs. See kb.vmware.com/kb/2125437 . If the issue persists, please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705

vmwNsxMCntnrUpdatePublishFailedNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.3.0.23

Publishing of container (IP/MAC/vNIC) update pdate failed for a given host/cluster object. Please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705

vmwNsxMConfigGroupNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.0.1.0.1

Configuration notifications that are grouped will have this OID prefix.

vmwNsxMConnPerSecThrshldCrossedNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.3.0.19

vsfwd Connectons Per Second (CPS) threshold exceeded. Reduce the amount of new connections of VMs on the host in question.

vmwNsxMControllerVmDeletedNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.20.0.25

NSX manager detected a Controller Virtual Machine is deleted from vCenter. Action required: Click on the Resolve button on Controller page on UI or call the API (POST https://<nsx-manager-host>/api/2.0/vdn/controller/{controllerId}?action=remediate) to clean up NSX manager's database state. Frequency of traps: This event will be raised when Controller Virtual Machine is deleted from vCenter. Affects: Controller cluster status might go to disconnected if a controller Virtual Machine is powered off. Any operation that requires an active Controller Cluster may be affected.

vmwNsxMControllerVmPoweredOffNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.20.0.24

NSX manager detected a Controller Virtual Machine is powered off from vCenter. Action required: Click on the 'Resolve' button on Controller page on UI or call the API (POST https://<nsx-manager-host>/api/2.0/vdn/controller/{controllerId}?action=remediate) to power on the Controller Virtual Machine. Frequency of traps: This event wil be raised when controller Virtual Machine is powered off from vCenter. Affects: Controller cluster status might go to disconnected if a controller Virtual Machine is powered off. Any operation that requires an active Controller Cluster may be affected.

vmwNsxMDataSecScanEndedNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.16.0.2

A notification generated when NSX Data Security scan ended on VirtualMachine.

vmwNsxMDataSecScanStartedNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.16.0.1

A notification generated when NSX Data Security scan started on VirtualMachine.

vmwNsxMDataStoreNotCnfgrdOnHostNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.7.0.5

Datastore could not be configured on host, probably its not connected. Action required: Ensure that datastore is connected to the host. Use resolve API to resolve the Alarm. Service will be deployed. Frequency of traps: Once per cluster per user operation [Deploy].

vmwNsxMDepPluginGenericAlarmNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.8.0.2

Deployment plugin generic alarm. Action required: Use resolve API to resolve the Alarm. Service will be deployed. Frequency of traps: N times per cluster, where N is number of hosts in the cluster.

vmwNsxMDepPluginGenericExceptionNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.8.0.3

Deployment plugin generic exception alarm. Action required: Use resolve API to resolve the Alarm. Service will be deployed. Frequency of traps: N times per cluster, where N is number of hosts in the cluster.

vmwNsxMDepPluginIpPoolExhaustedNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.8.0.1

When deploying Guest Introspection or other VM based service with static IP, NSX Manager needs to have a IP pool, for IP assignment to the VM. This pool has been exhausted, and new service VMs cannot be provisioned. Action required: Traverse to the Networking & Security page on VMWare vSphere Web Client, then go to Installation, followed by Service Deployments. Note the IP pool name for the failed service. Now traverse to NSX Managers, then go to Manage tab, followed by Grouping Objects sub-tab. Click on IP Pools, and add more Ips to the static IP pool. Use resolve API to resolve the Alarm. Service will be deployed. Frequency of traps: N times per cluster, where N is number of hosts in the cluster.

vmwNsxMDepPluginVmRebootNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.8.0.4

VM needs to be rebooted for some changes to be made/take effect. Action required: Use resolve API to resolve the Alarm. Frequency of traps: N times per cluster, where N is number of hosts in the cluster.

vmwNsxMDhcpServiceDisabledNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.4.0.60

A notification generated when DHCP Relay Service is disabled.

vmwNsxMDuplicateIpNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.19.0.3

The NSX Manager IP has been assigned to another machine Action: None Frequency: This is triggered whenever NSX Manager detects that its IP address is being used by another machine in the same network

vmwNsxMEamGenericAlarmNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.6.0.1

EAM reports problems to NSX during vib/service VM install/upgrade as these traps. Action required: Use resolve API to resolve the Alarm. Frequency of traps: N times per cluster per user action, where N is number of hosts in a cluster.

vmwNsxMEdgeAesniCryptoEngineDownNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.4.0.36

A notification generated when AESNI crypto engine is down. Action required: None

vmwNsxMEdgeAesniCryptoEngineUpNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.4.0.35

A notification generated when AESNI crypto engine is up. Action required: None

vmwNsxMEdgeAntiAffinityRuleViolatedNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.4.0.19

A notification generated when powering on NSX Edge appliance violates a virtual machine anti-affinity rule. Action required: Anti affinity rules removed from cluster. Both HA VM may run on same host. Go to VC and please revisit anti affinity rules on Cluster

vmwNsxMEdgeApplianceMovedNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.90.1.2.4.0.12

A notification generated when Edge appliance is moved in the vCenter inventory.

More MIBs from VMware

Browse all VMwareMIBs →
LSERIES-TAPE-LIBRARY-MIB

Standard SNMP MIB module defining data structures for LSERIES-TAPE-LIBRARY-MIB.

387 objects→
VMWARE-VRNI-MIB

The VMWARE-VRNI-MIB module enables SNMP-based monitoring of VMware vRealize Network Insight telemetry, specifically exposing virtual network topology, flow statistics, and security policy enforcement states for NSX and vSphere environments. This MIB facilitates the collection of granular metrics regarding virtual switch performance, distributed firewall rule utilization, and logical network path analysis to support capacity planning and anomaly detection.

171 objects→
VELOCLOUD-EDGE-MIB

SNMP MIB module

111 objects→
VMWARE-VCOPS-EVENT-MIB

The VMWARE-VCOPS-EVENT-MIB defines the structure for SNMP traps generated by VMware vCenter Operations Manager to report infrastructure health events, including performance thresholds, capacity warnings, and system anomalies. This module enables external monitoring systems to parse and correlate specific operational alerts from the vCenter Operations Manager environment.

72 objects→
VMWARE-VMINFO-MIB

The VMWARE-VMINFO-MIB enables SNMP-based polling and event notification for VMware ESXi host inventory and virtual machine state transitions, mapping specific managed objects to VMware VIM API properties. This module facilitates the collection of critical VM metrics including power status, resource allocation, and host association data for centralized infrastructure monitoring.

59 objects→
VMWARE-ENV-MIB

The VMWARE-ENV-MIB module exposes IPMI-defined hardware component status and environmental telemetry, including temperature, voltage, fan speed, and power supply states, for VMware ESXi hosts. It enables centralized monitoring of physical infrastructure health by mapping these low-level sensor readings to standard SNMP objects for alerting and capacity planning.

57 objects→