Home/Catalog/VMWARE-ENV-MIB

VMWARE-ENV-MIB

AI MIB Summary

The VMWARE-ENV-MIB module exposes IPMI-defined hardware component status and environmental telemetry, including temperature, voltage, fan speed, and power supply states, for VMware ESXi hosts. It enables centralized monitoring of physical infrastructure health by mapping these low-level sensor readings to standard SNMP objects for alerting and capacity planning.

This MIB module identifies hardware components of a machine as provided by IPMI.
Main OID:
vmwEnvironmentalMIB.1.3.6.1.4.1.6876.4.20.10
57
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

57 total
Object Name
vmwEnvHardwareEventdeprecated
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.0.301
vmwESXNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.4.1.0
vmwESXEnvHardwareEventdeprecated
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.4.1.0.301
vmwESXEnvHardwareAlert
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.4.1.0.302
vmwESXEnvBatteryAlert
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.4.1.0.303
vmwESXEnvChassisAlert
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.4.1.0.304
vmwESXEnvThermalAlert
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.4.1.0.305
vmwESXEnvDiskAlert
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.4.1.0.306
vmwESXEnvPowerAlert
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.4.1.0.307
vmwESXEnvProcessorAlert
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.4.1.0.308
vmwESXEnvMemoryAlert
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.4.1.0.309
vmwESXEnvBIOSAlert
NOTIFICATION-TYPE
.1.3.6.1.4.1.6876.4.1.0.310
vmwEnv
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.4.20
vmwEnvNumberro
Integer32
.1.3.6.1.4.1.6876.4.20.1
vmwEnvLastChangero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.6876.4.20.2
vmwEnvTable
SEQUENCE OF VmwEnvEntry
.1.3.6.1.4.1.6876.4.20.3
vmwEnvEntry
VmwEnvEntry
.1.3.6.1.4.1.6876.4.20.3.1
vmwEnvIndex
Integer32
.1.3.6.1.4.1.6876.4.20.3.1.1
vmwSubsystemTypero
VmwSubsystemTypes (VMWARE-TC-MIB)
.1.3.6.1.4.1.6876.4.20.3.1.2
vmwHardwareStatusro
VmwSubsystemStatus (VMWARE-TC-MIB)
.1.3.6.1.4.1.6876.4.20.3.1.3
vmwEventDescriptionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.6876.4.20.3.1.4
vmwEnvHardwareTimero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.6876.4.20.3.1.5
vmwEnvironmentalMIB
MODULE-IDENTITY
.1.3.6.1.4.1.6876.4.20.10
vmwEnvironmentalMIBConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.4.20.10.2
vmwEnvironmentMIBCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.4.20.10.2.1
vmwEnvMIBBasicComplianceobsolete
Unknown
.1.3.6.1.4.1.6876.4.20.10.2.1.2
vmwEnvMIBBasicCompliance2deprecated
Unknown
.1.3.6.1.4.1.6876.4.20.10.2.1.3
vmwEnvMIBBasicCompliance3
Unknown
.1.3.6.1.4.1.6876.4.20.10.2.1.4
vmwEnvMIBGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.4.20.10.2.2
vmwEnvironmentGroupdeprecated
Unknown
.1.3.6.1.4.1.6876.4.20.10.2.2.1
vmwEnvNotificationGroupdeprecated
Unknown
.1.3.6.1.4.1.6876.4.20.10.2.2.2
vmwESXEnvNotificationGroupdeprecated
Unknown
.1.3.6.1.4.1.6876.4.20.10.2.2.3
vmwESXEnvNotificationGroup2
Unknown
.1.3.6.1.4.1.6876.4.20.10.2.2.4
vmwEnvAlertGroup
Unknown
.1.3.6.1.4.1.6876.4.20.10.2.2.5
vmwEnvSourcero
Enumeration
.1.3.6.1.4.1.6876.4.20.100
vmwEnvInIndicationsro
Counter32
.1.3.6.1.4.1.6876.4.20.101
vmwEnvLastInro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.6876.4.20.102
vmwEnvOutNotificationsro
Counter32
.1.3.6.1.4.1.6876.4.20.103
vmwEnvInErrsro
Counter32
.1.3.6.1.4.1.6876.4.20.104
vmwEnvIndOidErrsro
Counter32
.1.3.6.1.4.1.6876.4.20.105
vmwEnvCvtValueErrsro
Counter32
.1.3.6.1.4.1.6876.4.20.106
vmwEnvCvtSyntaxErrsro
Counter32
.1.3.6.1.4.1.6876.4.20.107
vmwEnvCvtOidErrsro
Counter32
.1.3.6.1.4.1.6876.4.20.108
vmwEnvGetClassErrsro
Counter32
.1.3.6.1.4.1.6876.4.20.109
vmwEnvPropertySkipsro
Counter32
.1.3.6.1.4.1.6876.4.20.110
vmwEnvIndicationSkipsro
Counter32
.1.3.6.1.4.1.6876.4.20.111
vmwEnvCIM
OBJECT IDENTIFIER
.1.3.6.1.4.1.6876.4.30
vmwEnvDescriptionro
VmwLongSnmpAdminString (VMWARE-TC-MIB)
.1.3.6.1.4.1.6876.4.30.1
vmwEnvEventTimero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.6876.4.30.2
vmwEnvIndicationTimero
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.6876.4.30.3
vmwEnvPerceivedSeverityro
VmwCIMSeverity (VMWARE-TC-MIB)
.1.3.6.1.4.1.6876.4.30.4
vmwEnvAlertTypero
VmwCIMAlertTypes (VMWARE-TC-MIB)
.1.3.6.1.4.1.6876.4.30.5
vmwEnvSysCreationClassNamero
VmwCimName (VMWARE-TC-MIB)
.1.3.6.1.4.1.6876.4.30.6
vmwEnvAlertingElementro
VmwCimName (VMWARE-TC-MIB)
.1.3.6.1.4.1.6876.4.30.7
vmwEnvAlertingFormatro
VmwCIMAlertFormat (VMWARE-TC-MIB)
.1.3.6.1.4.1.6876.4.30.8
vmwEnvSystemNamero
VmwCimName (VMWARE-TC-MIB)
.1.3.6.1.4.1.6876.4.30.9
vmwEnvProviderNamero
VmwCimName (VMWARE-TC-MIB)
.1.3.6.1.4.1.6876.4.30.10

VMWARE-ENV-MIB Technical Reference Overview

The VMWARE-ENV-MIB SNMP MIB module published by VMware defines 57 managed OID objects, including 37 scalar/column metrics, 1 SNMP tables, and 11 trap/notification events anchored at base OID .1.3.6.1.4.1.6876.4.20.10. Key tabular structures include vmwEnvTable. Monitored SNMP traps/notifications include vmwESXEnvBIOSAlert, vmwESXEnvBatteryAlert, vmwESXEnvChassisAlert, vmwESXEnvDiskAlert, vmwESXEnvHardwareAlert, vmwESXEnvHardwareEvent.

Key OID Definitions in VMWARE-ENV-MIB

vmwEnvironmentalMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.6876.4.20.10

This MIB module identifies hardware components of a machine as provided by IPMI.

vmwEnvTableSEQUENCEnot-accessible
.1.3.6.1.4.1.6876.4.20.3

This table is populated from monitoring subsystems such as IPMI One conceptual row is maintained for each reporting component. Conceptual rows are not persistent across device resets

vmwESXEnvBIOSAlertNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.4.1.0.310

BIOS System Event Log alert as received from the Common Infrastructure Management (CIM) subsystem on this system.

vmwESXEnvBatteryAlertNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.4.1.0.303

A battery alert as received from the Common Infrastructure Management (CIM) subsystem on this system.

vmwESXEnvChassisAlertNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.4.1.0.304

A chassis alert as received from the Common Infrastructure Management (CIM) subsystem on this system.

vmwESXEnvDiskAlertNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.4.1.0.306

A disk drive alert as received from the Common Infrastructure Management (CIM) subsystem on this system.

vmwESXEnvHardwareAlertNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.4.1.0.302

A hardware alert as received from the Common Infrastructure Management (CIM) subsystem on this system.

vmwESXEnvHardwareEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.4.1.0.301

ESX Specific version of this notification, if the agent is so configured, may be sent when the ESX Operating System has detected a material change in physical condition of the hardware

vmwESXEnvMemoryAlertNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.4.1.0.309

A IPMI memory alert as received from the Common Infrastructure Management (CIM) subsystem on this system.

vmwESXEnvPowerAlertNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.4.1.0.307

A power suppply alert as received from the Common Infrastructure Management (CIM) subsystem on this system.

vmwESXEnvProcessorAlertNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.4.1.0.308

A IPMI processor alert as received from the Common Infrastructure Management (CIM) subsystem on this system.

vmwESXEnvThermalAlertNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.4.1.0.305

A cooling/thermal alert as received from the Common Infrastructure Management (CIM) subsystem on this system.

vmwEnvHardwareEventNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.6876.0.301

This notification, if the agent is so configured, may be sent when the system has detected a material change in physical condition of the hardware

vmwESXEnvNotificationGroupunknownnot-accessible
.1.3.6.1.4.1.6876.4.20.10.2.2.3

ESX System specific notifications about physical subsystems.

vmwESXEnvNotificationGroup2unknownnot-accessible
.1.3.6.1.4.1.6876.4.20.10.2.2.4

ESX System specific notifications about physical subsystems.

vmwEnvAlertGroupunknownnot-accessible
.1.3.6.1.4.1.6876.4.20.10.2.2.5

These objects provide physical hardware environmental details as reported by CIM subsystem.

vmwEnvAlertTypeVmwCIMAlertTypesaccessible-for-notify
.1.3.6.1.4.1.6876.4.30.5

Primary classification of the Indication.

vmwEnvAlertingElementVmwCimNameaccessible-for-notify
.1.3.6.1.4.1.6876.4.30.7

The identifying information of the entity (ie, the instance) for which this notification is generated. The property contains the CIM path of an CIM object instance, encoded as a string parameter - if the instance is modeled in the CIM Schema. If not a CIM instance, the property contains some identifying string that names the entity for which the Alert is generated. The path or identifying string is formatted per the AlertingElementFormat property.

vmwEnvAlertingFormatVmwCIMAlertFormataccessible-for-notify
.1.3.6.1.4.1.6876.4.30.8

The format of the AlertingManagedElement property is interpretable based upon the value of this property.

vmwEnvCvtOidErrsCounter32read-only
.1.3.6.1.4.1.6876.4.20.108

Number of CIM Indication properties having a MappingString qualifier for which the the oid was not valid.

vmwEnvCvtSyntaxErrsCounter32read-only
.1.3.6.1.4.1.6876.4.20.107

Number of CIM Indication properties having a MappingString qualifier for which the cim type could not be converted to smi syntax.

vmwEnvCvtValueErrsCounter32read-only
.1.3.6.1.4.1.6876.4.20.106

Number of CIM Indication properties having a MappingString qualifier for which the cim value for the given cim type could not be converted.

vmwEnvDescriptionVmwLongSnmpAdminStringaccessible-for-notify
.1.3.6.1.4.1.6876.4.30.1

A short description of the Indication.

vmwEnvEventTimeDateAndTimeaccessible-for-notify
.1.3.6.1.4.1.6876.4.30.2

The time and date the underlying event was first detected. May be set to the time the SNMP agent recieved the notification if in the incoming CIM indication the value is NULL due to the creating entity not being capable of providing this information. This value is based on the notion of local date and time of the Managed System Element generating the Indication.

More MIBs from VMware

Browse all VMwareMIBs →
LSERIES-TAPE-LIBRARY-MIB

Standard SNMP MIB module defining data structures for LSERIES-TAPE-LIBRARY-MIB.

387 objects→
VMWARE-NSX-MANAGER-MIB

The VMWARE-NSX-MANAGER-MIB module defines the structure for SNMP traps generated by the VMware NSX Manager virtual appliance to report critical state changes and events for software-defined networking components, including logical switches, edge services gateways, and controllers. This module enables network management systems to parse and correlate specific operational alerts and fault notifications from the NSX Manager within a vSphere environment.

277 objects→
VMWARE-VRNI-MIB

The VMWARE-VRNI-MIB module enables SNMP-based monitoring of VMware vRealize Network Insight telemetry, specifically exposing virtual network topology, flow statistics, and security policy enforcement states for NSX and vSphere environments. This MIB facilitates the collection of granular metrics regarding virtual switch performance, distributed firewall rule utilization, and logical network path analysis to support capacity planning and anomaly detection.

171 objects→
VELOCLOUD-EDGE-MIB

SNMP MIB module

111 objects→
VMWARE-VCOPS-EVENT-MIB

The VMWARE-VCOPS-EVENT-MIB defines the structure for SNMP traps generated by VMware vCenter Operations Manager to report infrastructure health events, including performance thresholds, capacity warnings, and system anomalies. This module enables external monitoring systems to parse and correlate specific operational alerts from the vCenter Operations Manager environment.

72 objects→
VMWARE-VMINFO-MIB

The VMWARE-VMINFO-MIB enables SNMP-based polling and event notification for VMware ESXi host inventory and virtual machine state transitions, mapping specific managed objects to VMware VIM API properties. This module facilitates the collection of critical VM metrics including power status, resource allocation, and host association data for centralized infrastructure monitoring.

59 objects→