VMWARE-ENV-MIB
The VMWARE-ENV-MIB module exposes IPMI-defined hardware component status and environmental telemetry, including temperature, voltage, fan speed, and power supply states, for VMware ESXi hosts. It enables centralized monitoring of physical infrastructure health by mapping these low-level sensor readings to standard SNMP objects for alerting and capacity planning.
Imported Objects
Objects
57 total| Object Name |
|---|
vmwEnvHardwareEventdeprecated NOTIFICATION-TYPE .1.3.6.1.4.1.6876.0.301 |
vmwESXNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.6876.4.1.0 |
vmwESXEnvHardwareEventdeprecated NOTIFICATION-TYPE .1.3.6.1.4.1.6876.4.1.0.301 |
vmwESXEnvHardwareAlert NOTIFICATION-TYPE .1.3.6.1.4.1.6876.4.1.0.302 |
vmwESXEnvBatteryAlert NOTIFICATION-TYPE .1.3.6.1.4.1.6876.4.1.0.303 |
vmwESXEnvChassisAlert NOTIFICATION-TYPE .1.3.6.1.4.1.6876.4.1.0.304 |
vmwESXEnvThermalAlert NOTIFICATION-TYPE .1.3.6.1.4.1.6876.4.1.0.305 |
vmwESXEnvDiskAlert NOTIFICATION-TYPE .1.3.6.1.4.1.6876.4.1.0.306 |
vmwESXEnvPowerAlert NOTIFICATION-TYPE .1.3.6.1.4.1.6876.4.1.0.307 |
vmwESXEnvProcessorAlert NOTIFICATION-TYPE .1.3.6.1.4.1.6876.4.1.0.308 |
vmwESXEnvMemoryAlert NOTIFICATION-TYPE .1.3.6.1.4.1.6876.4.1.0.309 |
vmwESXEnvBIOSAlert NOTIFICATION-TYPE .1.3.6.1.4.1.6876.4.1.0.310 |
vmwEnv OBJECT IDENTIFIER .1.3.6.1.4.1.6876.4.20 |
vmwEnvNumberro Integer32 .1.3.6.1.4.1.6876.4.20.1 |
vmwEnvLastChangero TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.6876.4.20.2 |
vmwEnvTable SEQUENCE OF VmwEnvEntry .1.3.6.1.4.1.6876.4.20.3 |
vmwEnvEntry VmwEnvEntry .1.3.6.1.4.1.6876.4.20.3.1 |
vmwEnvIndex Integer32 .1.3.6.1.4.1.6876.4.20.3.1.1 |
vmwSubsystemTypero VmwSubsystemTypes (VMWARE-TC-MIB) .1.3.6.1.4.1.6876.4.20.3.1.2 |
vmwHardwareStatusro VmwSubsystemStatus (VMWARE-TC-MIB) .1.3.6.1.4.1.6876.4.20.3.1.3 |
vmwEventDescriptionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6876.4.20.3.1.4 |
vmwEnvHardwareTimero TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.6876.4.20.3.1.5 |
vmwEnvironmentalMIB MODULE-IDENTITY .1.3.6.1.4.1.6876.4.20.10 |
vmwEnvironmentalMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.6876.4.20.10.2 |
vmwEnvironmentMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.6876.4.20.10.2.1 |
vmwEnvMIBBasicComplianceobsolete Unknown .1.3.6.1.4.1.6876.4.20.10.2.1.2 |
vmwEnvMIBBasicCompliance2deprecated Unknown .1.3.6.1.4.1.6876.4.20.10.2.1.3 |
vmwEnvMIBBasicCompliance3 Unknown .1.3.6.1.4.1.6876.4.20.10.2.1.4 |
vmwEnvMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.6876.4.20.10.2.2 |
vmwEnvironmentGroupdeprecated Unknown .1.3.6.1.4.1.6876.4.20.10.2.2.1 |
vmwEnvNotificationGroupdeprecated Unknown .1.3.6.1.4.1.6876.4.20.10.2.2.2 |
vmwESXEnvNotificationGroupdeprecated Unknown .1.3.6.1.4.1.6876.4.20.10.2.2.3 |
vmwESXEnvNotificationGroup2 Unknown .1.3.6.1.4.1.6876.4.20.10.2.2.4 |
vmwEnvAlertGroup Unknown .1.3.6.1.4.1.6876.4.20.10.2.2.5 |
vmwEnvSourcero Enumeration .1.3.6.1.4.1.6876.4.20.100 |
vmwEnvInIndicationsro Counter32 .1.3.6.1.4.1.6876.4.20.101 |
vmwEnvLastInro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.6876.4.20.102 |
vmwEnvOutNotificationsro Counter32 .1.3.6.1.4.1.6876.4.20.103 |
vmwEnvInErrsro Counter32 .1.3.6.1.4.1.6876.4.20.104 |
vmwEnvIndOidErrsro Counter32 .1.3.6.1.4.1.6876.4.20.105 |
vmwEnvCvtValueErrsro Counter32 .1.3.6.1.4.1.6876.4.20.106 |
vmwEnvCvtSyntaxErrsro Counter32 .1.3.6.1.4.1.6876.4.20.107 |
vmwEnvCvtOidErrsro Counter32 .1.3.6.1.4.1.6876.4.20.108 |
vmwEnvGetClassErrsro Counter32 .1.3.6.1.4.1.6876.4.20.109 |
vmwEnvPropertySkipsro Counter32 .1.3.6.1.4.1.6876.4.20.110 |
vmwEnvIndicationSkipsro Counter32 .1.3.6.1.4.1.6876.4.20.111 |
vmwEnvCIM OBJECT IDENTIFIER .1.3.6.1.4.1.6876.4.30 |
vmwEnvDescriptionro VmwLongSnmpAdminString (VMWARE-TC-MIB) .1.3.6.1.4.1.6876.4.30.1 |
vmwEnvEventTimero DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.6876.4.30.2 |
vmwEnvIndicationTimero DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.6876.4.30.3 |
vmwEnvPerceivedSeverityro VmwCIMSeverity (VMWARE-TC-MIB) .1.3.6.1.4.1.6876.4.30.4 |
vmwEnvAlertTypero VmwCIMAlertTypes (VMWARE-TC-MIB) .1.3.6.1.4.1.6876.4.30.5 |
vmwEnvSysCreationClassNamero VmwCimName (VMWARE-TC-MIB) .1.3.6.1.4.1.6876.4.30.6 |
vmwEnvAlertingElementro VmwCimName (VMWARE-TC-MIB) .1.3.6.1.4.1.6876.4.30.7 |
vmwEnvAlertingFormatro VmwCIMAlertFormat (VMWARE-TC-MIB) .1.3.6.1.4.1.6876.4.30.8 |
vmwEnvSystemNamero VmwCimName (VMWARE-TC-MIB) .1.3.6.1.4.1.6876.4.30.9 |
vmwEnvProviderNamero VmwCimName (VMWARE-TC-MIB) .1.3.6.1.4.1.6876.4.30.10 |
VMWARE-ENV-MIB Technical Reference Overview
The VMWARE-ENV-MIB SNMP MIB module published by VMware defines 57 managed OID objects, including 37 scalar/column metrics, 1 SNMP tables, and 11 trap/notification events anchored at base OID .1.3.6.1.4.1.6876.4.20.10. Key tabular structures include vmwEnvTable. Monitored SNMP traps/notifications include vmwESXEnvBIOSAlert, vmwESXEnvBatteryAlert, vmwESXEnvChassisAlert, vmwESXEnvDiskAlert, vmwESXEnvHardwareAlert, vmwESXEnvHardwareEvent.
Key OID Definitions in VMWARE-ENV-MIB
.1.3.6.1.4.1.6876.4.20.10This MIB module identifies hardware components of a machine as provided by IPMI.
.1.3.6.1.4.1.6876.4.20.3This table is populated from monitoring subsystems such as IPMI One conceptual row is maintained for each reporting component. Conceptual rows are not persistent across device resets
.1.3.6.1.4.1.6876.4.1.0.310BIOS System Event Log alert as received from the Common Infrastructure Management (CIM) subsystem on this system.
.1.3.6.1.4.1.6876.4.1.0.303A battery alert as received from the Common Infrastructure Management (CIM) subsystem on this system.
.1.3.6.1.4.1.6876.4.1.0.304A chassis alert as received from the Common Infrastructure Management (CIM) subsystem on this system.
.1.3.6.1.4.1.6876.4.1.0.306A disk drive alert as received from the Common Infrastructure Management (CIM) subsystem on this system.
.1.3.6.1.4.1.6876.4.1.0.302A hardware alert as received from the Common Infrastructure Management (CIM) subsystem on this system.
.1.3.6.1.4.1.6876.4.1.0.301ESX Specific version of this notification, if the agent is so configured, may be sent when the ESX Operating System has detected a material change in physical condition of the hardware
.1.3.6.1.4.1.6876.4.1.0.309A IPMI memory alert as received from the Common Infrastructure Management (CIM) subsystem on this system.
.1.3.6.1.4.1.6876.4.1.0.307A power suppply alert as received from the Common Infrastructure Management (CIM) subsystem on this system.
.1.3.6.1.4.1.6876.4.1.0.308A IPMI processor alert as received from the Common Infrastructure Management (CIM) subsystem on this system.
.1.3.6.1.4.1.6876.4.1.0.305A cooling/thermal alert as received from the Common Infrastructure Management (CIM) subsystem on this system.
.1.3.6.1.4.1.6876.0.301This notification, if the agent is so configured, may be sent when the system has detected a material change in physical condition of the hardware
.1.3.6.1.4.1.6876.4.20.10.2.2.3ESX System specific notifications about physical subsystems.
.1.3.6.1.4.1.6876.4.20.10.2.2.4ESX System specific notifications about physical subsystems.
.1.3.6.1.4.1.6876.4.20.10.2.2.5These objects provide physical hardware environmental details as reported by CIM subsystem.
.1.3.6.1.4.1.6876.4.30.5Primary classification of the Indication.
.1.3.6.1.4.1.6876.4.30.7The identifying information of the entity (ie, the instance) for which this notification is generated. The property contains the CIM path of an CIM object instance, encoded as a string parameter - if the instance is modeled in the CIM Schema. If not a CIM instance, the property contains some identifying string that names the entity for which the Alert is generated. The path or identifying string is formatted per the AlertingElementFormat property.
.1.3.6.1.4.1.6876.4.30.8The format of the AlertingManagedElement property is interpretable based upon the value of this property.
.1.3.6.1.4.1.6876.4.20.108Number of CIM Indication properties having a MappingString qualifier for which the the oid was not valid.
.1.3.6.1.4.1.6876.4.20.107Number of CIM Indication properties having a MappingString qualifier for which the cim type could not be converted to smi syntax.
.1.3.6.1.4.1.6876.4.20.106Number of CIM Indication properties having a MappingString qualifier for which the cim value for the given cim type could not be converted.
.1.3.6.1.4.1.6876.4.30.1A short description of the Indication.
.1.3.6.1.4.1.6876.4.30.2The time and date the underlying event was first detected. May be set to the time the SNMP agent recieved the notification if in the incoming CIM indication the value is NULL due to the creating entity not being capable of providing this information. This value is based on the notion of local date and time of the Managed System Element generating the Indication.
More MIBs from VMware
Browse all VMwareMIBs →Standard SNMP MIB module defining data structures for LSERIES-TAPE-LIBRARY-MIB.
The VMWARE-NSX-MANAGER-MIB module defines the structure for SNMP traps generated by the VMware NSX Manager virtual appliance to report critical state changes and events for software-defined networking components, including logical switches, edge services gateways, and controllers. This module enables network management systems to parse and correlate specific operational alerts and fault notifications from the NSX Manager within a vSphere environment.
The VMWARE-VRNI-MIB module enables SNMP-based monitoring of VMware vRealize Network Insight telemetry, specifically exposing virtual network topology, flow statistics, and security policy enforcement states for NSX and vSphere environments. This MIB facilitates the collection of granular metrics regarding virtual switch performance, distributed firewall rule utilization, and logical network path analysis to support capacity planning and anomaly detection.
SNMP MIB module
The VMWARE-VCOPS-EVENT-MIB defines the structure for SNMP traps generated by VMware vCenter Operations Manager to report infrastructure health events, including performance thresholds, capacity warnings, and system anomalies. This module enables external monitoring systems to parse and correlate specific operational alerts from the vCenter Operations Manager environment.
The VMWARE-VMINFO-MIB enables SNMP-based polling and event notification for VMware ESXi host inventory and virtual machine state transitions, mapping specific managed objects to VMware VIM API properties. This module facilitates the collection of critical VM metrics including power status, resource allocation, and host association data for centralized infrastructure monitoring.