Home/Catalog/Unisphere-Data-ERX-System-MIB

Unisphere-Data-ERX-System-MIB

AI MIB Summary

The Unisphere-Data-ERX-System-MIB facilitates SNMP-based monitoring and configuration of Dell EMC ERX Edge Router system resources, including CPU utilization, memory usage, interface status, and system health counters. It provides the standardized object identifiers required for integrating ERX Edge Router telemetry into centralized network management systems for fault detection and performance analysis.

MIB objects for managing ERX Edge Router systems.
Main OID:
usdERXSysMIB.1.3.6.1.4.1.4874.2.2.17
135
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

135 total
Object Name
usdERXSysMIB
MODULE-IDENTITY
.1.3.6.1.4.1.4874.2.2.17
usdERXSysTrap
OBJECT IDENTIFIER
.1.3.6.1.4.1.4874.2.2.17.0
usdERXSysSlotOperStatusChange
NOTIFICATION-TYPE
.1.3.6.1.4.1.4874.2.2.17.0.1
usdERXSysPowerStatusChange
NOTIFICATION-TYPE
.1.3.6.1.4.1.4874.2.2.17.0.2
usdERXSysTempFanStatusChange
NOTIFICATION-TYPE
.1.3.6.1.4.1.4874.2.2.17.0.3
usdERXSysTempStatusChange
NOTIFICATION-TYPE
.1.3.6.1.4.1.4874.2.2.17.0.4
usdERXSysHighMemUtil
NOTIFICATION-TYPE
.1.3.6.1.4.1.4874.2.2.17.0.5
usdERXSysAbatedMemUtil
NOTIFICATION-TYPE
.1.3.6.1.4.1.4874.2.2.17.0.6
usdERXSysTempProtectionStatusChange
NOTIFICATION-TYPE
.1.3.6.1.4.1.4874.2.2.17.0.7
usdERXSysObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.4874.2.2.17.1
usdERXSysGeneral
OBJECT IDENTIFIER
.1.3.6.1.4.1.4874.2.2.17.1.1
usdERXSysChassisRevro
Integer32
.1.3.6.1.4.1.4874.2.2.17.1.1.1
usdERXSysSwVersionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4874.2.2.17.1.1.2
usdERXSysSwBuildDatero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4874.2.2.17.1.1.3
usdERXSysRevertControlrw
Enumeration
.1.3.6.1.4.1.4874.2.2.17.1.1.4
usdERXSysRevertTimeOfDayrw
Integer32
.1.3.6.1.4.1.4874.2.2.17.1.1.5
usdERXSysBootConfigControlrw
Enumeration
.1.3.6.1.4.1.4874.2.2.17.1.1.6
usdERXSysBootBackupConfigControlrw
Enumeration
.1.3.6.1.4.1.4874.2.2.17.1.1.7
usdERXSysBootForceBackupControlrw
Enumeration
.1.3.6.1.4.1.4874.2.2.17.1.1.8
usdERXSysBootAutoRevertControlrw
Enumeration
.1.3.6.1.4.1.4874.2.2.17.1.1.9
usdERXSysBootAutoRevertCountTolerancerw
Unsigned32
.1.3.6.1.4.1.4874.2.2.17.1.1.10
usdERXSysBootAutoRevertTimeTolerancerw
Unsigned32
.1.3.6.1.4.1.4874.2.2.17.1.1.11
usdERXSysBootReleaseFilerw
DisplayString
.1.3.6.1.4.1.4874.2.2.17.1.1.12
usdERXSysBootConfigFilerw
DisplayString
.1.3.6.1.4.1.4874.2.2.17.1.1.13
usdERXSysBootBackupReleaseFilerw
DisplayString
.1.3.6.1.4.1.4874.2.2.17.1.1.14
usdERXSysBootBackupConfigFilerw
DisplayString
.1.3.6.1.4.1.4874.2.2.17.1.1.15
usdERXSysAdminTimingSourcerw
UsdTimingSelector
.1.3.6.1.4.1.4874.2.2.17.1.1.16
usdERXSysOperTimingSourcero
UsdTimingSelector
.1.3.6.1.4.1.4874.2.2.17.1.1.17
usdERXSysTimingDisableAutoUpgraderw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.4874.2.2.17.1.1.18
usdERXSysTimingSelectorTable
SEQUENCE OF UsdERXSysTimingSelectorEntry
.1.3.6.1.4.1.4874.2.2.17.1.1.19
usdERXSysTimingSelectorEntry
UsdERXSysTimingSelectorEntry
.1.3.6.1.4.1.4874.2.2.17.1.1.19.1
usdERXSysTimingSelectorIndex
UsdTimingSelector
.1.3.6.1.4.1.4874.2.2.17.1.1.19.1.1
usdERXSysTimingSourceTyperw
UsdTimingSourceType
.1.3.6.1.4.1.4874.2.2.17.1.1.19.1.2
usdERXSysTimingSourceIfIndexrw
InterfaceIndexOrZero (IF-MIB)
.1.3.6.1.4.1.4874.2.2.17.1.1.19.1.3
usdERXSysTimingSourceLinerw
UsdTimingSourceLineType
.1.3.6.1.4.1.4874.2.2.17.1.1.19.1.4
usdERXSysTimingStatusro
Enumeration
.1.3.6.1.4.1.4874.2.2.17.1.1.19.1.5
usdERXSysMemUtilPctro
Integer32 (-1..100) UNITS "percent"
.1.3.6.1.4.1.4874.2.2.17.1.1.20
usdERXSysMemCapacityro
Integer32 UNITS "bytes"
.1.3.6.1.4.1.4874.2.2.17.1.1.21
usdERXSysHighMemUtilThresholdrw
Integer32
.1.3.6.1.4.1.4874.2.2.17.1.1.22
usdERXSysAbatedMemUtilThresholdrw
Integer32
.1.3.6.1.4.1.4874.2.2.17.1.1.23
usdERXSysMemUtilTrapEnablerw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.4874.2.2.17.1.1.24
usdERXSysFabric
OBJECT IDENTIFIER
.1.3.6.1.4.1.4874.2.2.17.1.2
usdERXSysFabricSpeedro
Integer32 UNITS "gigabits per second"
.1.3.6.1.4.1.4874.2.2.17.1.2.1
usdERXSysFabricRevro
Integer32
.1.3.6.1.4.1.4874.2.2.17.1.2.2
usdERXSysNvs
OBJECT IDENTIFIER
.1.3.6.1.4.1.4874.2.2.17.1.3
usdERXSysNvsStatusro
Enumeration
.1.3.6.1.4.1.4874.2.2.17.1.3.1
usdERXSysNvsCapacityro
Integer32 UNITS "megabytes"
.1.3.6.1.4.1.4874.2.2.17.1.3.2
usdERXSysNvsUtilPctro
Integer32 (-1..100) UNITS "percent"
.1.3.6.1.4.1.4874.2.2.17.1.3.3
usdERXSysSlot
OBJECT IDENTIFIER
.1.3.6.1.4.1.4874.2.2.17.1.4
usdERXSysSlotCountro
Integer32
.1.3.6.1.4.1.4874.2.2.17.1.4.1
usdERXSysSlotTable
SEQUENCE OF UsdERXSysSlotEntry
.1.3.6.1.4.1.4874.2.2.17.1.4.2
usdERXSysSlotEntry
UsdERXSysSlotEntry
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1
usdERXSysSlotIndex
Integer32
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.1
usdERXSysSlotDescrro
DisplayString
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.2
usdERXSysSlotCurrentCardTypero
UsdSysCardType
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.3
usdERXSysSlotRevro
Integer32
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.4
usdERXSysSlotAdminStatusrw
UsdEnable (Unisphere-Data-TC)
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.5
usdERXSysSlotOperStatusro
Enumeration
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.6
usdERXSysSlotDisableReasonro
Enumeration
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.7
usdERXSysSlotExpectedCardTypero
UsdSysCardType
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.8
usdERXSysSlotControlrw
Enumeration
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.9
usdERXSysSlotCpuUtilPctro
Integer32 (-1..100) UNITS "percent"
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.10
usdERXSysSlotMemUtilPctro
Integer32 (-1..100) UNITS "percent"
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.11
usdERXSysSlotIoaPresentro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.12
usdERXSysSlotPortCountro
Integer32
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.13
usdERXSysSlotLastChangero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.14
usdERXSysSlotRedundancyLockoutrw
UsdEnable (Unisphere-Data-TC)
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.15
usdERXSysSlotRedundancyGroupIdro
Unsigned32
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.16
usdERXSysSlotSpareServerro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.17
usdERXSysSlotAssociatedSlotro
Integer32
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.18
usdERXSysSlotRevertControlrw
Enumeration
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.19
usdERXSysSlotRedundancyRevertTimerw
DateAndTime (SNMPv2-TC)
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.20
usdERXSysSlotBootReleaseFilerw
DisplayString
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.21
usdERXSysSlotBootBackupReleaseFilerw
DisplayString
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.22
usdERXSysSlotSerialNumberro
DisplayString
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.23
usdERXSysSlotAssemblyPartNumberro
DisplayString
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.24
usdERXSysSlotAssemblyRevro
DisplayString
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.25
usdERXSysSlotIoaSerialNumberro
DisplayString
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.26
usdERXSysSlotIoaAssemblyPartNumberro
DisplayString
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.27
usdERXSysSlotIoaAssemblyRevro
DisplayString
.1.3.6.1.4.1.4874.2.2.17.1.4.2.1.28
usdERXSysPort
OBJECT IDENTIFIER
.1.3.6.1.4.1.4874.2.2.17.1.5
usdERXSysPortTable
SEQUENCE OF UsdERXSysPortEntry
.1.3.6.1.4.1.4874.2.2.17.1.5.1
usdERXSysPortEntry
UsdERXSysPortEntry
.1.3.6.1.4.1.4874.2.2.17.1.5.1.1
usdERXSysPortIndex
Integer32
.1.3.6.1.4.1.4874.2.2.17.1.5.1.1.1
usdERXSysPortDescrro
DisplayString
.1.3.6.1.4.1.4874.2.2.17.1.5.1.1.2
usdERXSysPortTypero
Enumeration
.1.3.6.1.4.1.4874.2.2.17.1.5.1.1.3
usdERXSysPortIfIndexro
InterfaceIndexOrZero (IF-MIB)
.1.3.6.1.4.1.4874.2.2.17.1.5.1.1.4
usdERXSysPower
OBJECT IDENTIFIER
.1.3.6.1.4.1.4874.2.2.17.1.6
usdERXSysPowerTable
SEQUENCE OF UsdERXSysPowerEntry
.1.3.6.1.4.1.4874.2.2.17.1.6.1
usdERXSysPowerEntry
UsdERXSysPowerEntry
.1.3.6.1.4.1.4874.2.2.17.1.6.1.1
usdERXSysPowerIndex
Integer32
.1.3.6.1.4.1.4874.2.2.17.1.6.1.1.1
usdERXSysPowerDescrro
DisplayString
.1.3.6.1.4.1.4874.2.2.17.1.6.1.1.2
usdERXSysPowerStatusro
Enumeration
.1.3.6.1.4.1.4874.2.2.17.1.6.1.1.3
usdERXSysTemperature
OBJECT IDENTIFIER
.1.3.6.1.4.1.4874.2.2.17.1.7
usdERXSysTempFanStatusro
Enumeration
.1.3.6.1.4.1.4874.2.2.17.1.7.1
usdERXSysTempTable
SEQUENCE OF UsdERXSysTempEntry
.1.3.6.1.4.1.4874.2.2.17.1.7.2
usdERXSysTempEntry
UsdERXSysTempEntry
.1.3.6.1.4.1.4874.2.2.17.1.7.2.1
usdERXSysTempIndex
Integer32
.1.3.6.1.4.1.4874.2.2.17.1.7.2.1.1
usdERXSysTempDescrro
DisplayString
.1.3.6.1.4.1.4874.2.2.17.1.7.2.1.2
usdERXSysTempStatusro
Enumeration
.1.3.6.1.4.1.4874.2.2.17.1.7.2.1.3
Showing 100 of 135 OID objects

Unisphere-Data-ERX-System-MIB Technical Reference Overview

The Unisphere-Data-ERX-System-MIB SNMP MIB module published by Unisphere defines 135 managed OID objects, including 102 scalar/column metrics, 6 SNMP tables, and 7 trap/notification events anchored at base OID .1.3.6.1.4.1.4874.2.2.17. Key tabular structures include usdERXSysPortTable, usdERXSysPowerTable, usdERXSysSlotTable, usdERXSysSubsystemTable, usdERXSysTempTable, usdERXSysTimingSelectorTable. Monitored SNMP traps/notifications include usdERXSysAbatedMemUtil, usdERXSysHighMemUtil, usdERXSysPowerStatusChange, usdERXSysSlotOperStatusChange, usdERXSysTempFanStatusChange, usdERXSysTempProtectionStatusChange.

Key OID Definitions in Unisphere-Data-ERX-System-MIB

usdERXSysMIBMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.4874.2.2.17

MIB objects for managing ERX Edge Router systems.

usdERXSysPortTableSEQUENCEnot-accessible
.1.3.6.1.4.1.4874.2.2.17.1.5.1

Table of system physical ports. The information in this table reflects the ports for the EXPECTED card type in each slot; in event of a card mismatch, this table permits navigation of the existing configuration of the expected card type.

usdERXSysPowerTableSEQUENCEnot-accessible
.1.3.6.1.4.1.4874.2.2.17.1.6.1

Table of system power elements.

usdERXSysSlotTableSEQUENCEnot-accessible
.1.3.6.1.4.1.4874.2.2.17.1.4.2

Table of system slots.

usdERXSysSubsystemTableSEQUENCEnot-accessible
.1.3.6.1.4.1.4874.2.2.17.1.8.1

Table of subsystems.

usdERXSysTempTableSEQUENCEnot-accessible
.1.3.6.1.4.1.4874.2.2.17.1.7.2

Table of system temperature sensors. Sensors are distributed across the chassis, at least one sensor per populated slot.

usdERXSysTimingSelectorTableSEQUENCEnot-accessible
.1.3.6.1.4.1.4874.2.2.17.1.1.19

Table of system timing selectors.

usdERXSysAbatedMemUtilNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.4874.2.2.17.0.6

Reports system memory utilization has met the conditions of usdERXSysAbatedMemUtilThreshold.

usdERXSysHighMemUtilNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.4874.2.2.17.0.5

Report system memory utilization has met the conditions of usdERXSysHighMemUtilThreshold.

usdERXSysPowerStatusChangeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.4874.2.2.17.0.2

Reports a change in the status of a power element.

usdERXSysSlotOperStatusChangeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.4874.2.2.17.0.1

Reports a status change for a slot. This trap is generated on a transition into a stable state (online or disabled) or on a transition out of online.

usdERXSysTempFanStatusChangeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.4874.2.2.17.0.3

Reports a transition between the three states of the fan subsystem. When the fan subsystem transitions to the failed state the thermal protection hold off time begins.

usdERXSysTempProtectionStatusChangeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.4874.2.2.17.0.7

Notification about changes in the state of Thermal Protection. This notification is sent when the tempProtectionStatus changes. It is also sent when the holdOffTimeRemaining is 50% of the holdOffTime.

usdERXSysTempStatusChangeNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.4874.2.2.17.0.4

Reports a change in the temperature status. When the status transitions to the tooHigh state the system enters thermal protection mode.

usdERXSysAbatedMemUtilThresholdInteger32read-write
.1.3.6.1.4.1.4874.2.2.17.1.1.23

The value of system memory utilization that is used to determine when to generate an abated memory utilization event notification to the management entity on this system. The value of this object must be less than the value of usdERXSysHighMemUtilThreshold. The abated memory utilization trap is sent once if the high memory threshold was reached, and memory utilization falls to the value of this object.

usdERXSysAdminTimingSourceUsdTimingSelectorread-write
.1.3.6.1.4.1.4874.2.2.17.1.1.16

The administrative timing source for the ERX system. The ERX periodically monitors the status of three timing sources, primary, secondary and tertiary. If the systems current timing source fails, the system will automatically downgrade to the next timing source. If the system is configured to automatically upgrade (usdERXSysTimingDisableAutoUpgrade is set to false(2)) the system will switch back to the higher timing source when it becomes available. A timing source failure can be detected by comparing the operational and admin timing sources. If they are not equal, the system has swapped timing sources because the administratively set value is in the error state.

usdERXSysBootAutoRevertControlINTEGERread-write
.1.3.6.1.4.1.4874.2.2.17.1.1.9

System boot auto revert control: default Use default auto-revert tolerances. never Never auto-revert to backup. set Set auto-revert settings at specified tolerances.

usdERXSysBootAutoRevertCountToleranceUnsigned32read-write
.1.3.6.1.4.1.4874.2.2.17.1.1.10

The auto-revert reboot count tolerance. This object cannot be set to zero, but may contain a zero value when the control is set to never(1).

usdERXSysBootAutoRevertTimeToleranceUnsigned32read-write
.1.3.6.1.4.1.4874.2.2.17.1.1.11

The auto-revert reboot time tolerance. This object cannot be set to zero, but will contain a zero value when the control is set to never(1).

usdERXSysBootBackupConfigControlINTEGERread-write
.1.3.6.1.4.1.4874.2.2.17.1.1.7

System boot backup configuration control: file Revert to backup configuration settings specified by usdERXSysBootBackupConfigFile. The usdERXSysBootBackupConfigControl and usdERXSysBootBackupConfigFile must be specified together in the same set request PDU. factoryDefaults Revert to factory default settings. none Specify no backup.

usdERXSysBootBackupConfigFileDisplayStringread-write
.1.3.6.1.4.1.4874.2.2.17.1.1.15

The local backup boot configuration file name, with extension .cnf. The usdERXSysBootBackupConfigControl and usdERXSysBootBackupConfigFile must be specified together in the same set request PDU.

usdERXSysBootBackupReleaseFileDisplayStringread-write
.1.3.6.1.4.1.4874.2.2.17.1.1.14

The local backup boot release file name, with extension .rel.

usdERXSysBootConfigControlINTEGERread-write
.1.3.6.1.4.1.4874.2.2.17.1.1.6

System boot configuration control: file Revert to configuration settings specified by usdERXSysBootConfigFile. The usdERXSysBootConfigControl and usdERXSysBootConfigFile must be specified together in the same set request PDU. fileOnce Revert to configuration settings specified by usdERXSysBootConfigFile. Do not continue to use file after using it once. The usdERXSysBootConfigControl and usdERXSysBootConfigFile must be specified together in the same set request PDU. factoryDefaults Revert to factory default settings. runningConfiguration Revert to current settings.

usdERXSysBootConfigFileDisplayStringread-write
.1.3.6.1.4.1.4874.2.2.17.1.1.13

The local boot configuration file name, with extension .cnf. The usdERXSysBootConfigControl and usdERXSysBootConfigFile must be specified together in the same set request PDU.

More MIBs from Unisphere

Browse all UnisphereMIBs →