TRISTAR-MPPT-600V
The TRISTAR-MPPT-600V MIB module enables SNMP-based monitoring and management of Morningstar TriStar-MPPT-600V solar charge controllers, specifically exposing photovoltaic input/output parameters such as array voltage, current, power, and MPPT tracking status. It facilitates the collection of real-time telemetry and operational counters required for remote system diagnostics and performance verification of the 600V DC solar charging infrastructure.
Imported Objects
Objects
35 total| Object Name |
|---|
tristarmppt600vMorningstar Product: TriStar-MPPT-600V
Device Type: 9
Device Model: 0
Meterbus Type: 9
Copyright (C) Morningstar Corporation (2019).
All Rights Reserved MODULE-IDENTITY .1.3.6.1.4.1.33333.7 |
subModelThe device's exact modelro DisplayString .1.3.6.1.4.1.33333.7.1 |
serialNumberDevice Serial Numberro DisplayString .1.3.6.1.4.1.33333.7.2 |
deviceVersionHardware and firmware versions: vHW1.HW2.FWro DisplayString .1.3.6.1.4.1.33333.7.3 |
arrayVoltageArray Voltage
- Description: Array Voltage
- Scaling Factor: 1.0
- Units: V
- Range: [-10, 650]
- Modbus address: 0x001bro DisplayString .1.3.6.1.4.1.33333.7.30 |
arrayCurrentArray Current
- Description: Array Current
- Scaling Factor: 1.0
- Units: A
- Range: [-10, 80]
- Modbus address: 0x001dro DisplayString .1.3.6.1.4.1.33333.7.31 |
inputPowerInput Power
- Description: Input Power
- Scaling Factor: 1.0
- Units: W
- Range: [-4000, 4000]
- Modbus address: 0x003bro DisplayString .1.3.6.1.4.1.33333.7.32 |
arrayPmaxLastSweepArray Pmax(last sweep)
- Description: Pmax (last sweep)
- Scaling Factor: 1.0
- Units: W
- Range: [-10, 5000]
- Modbus address: 0x003cro DisplayString .1.3.6.1.4.1.33333.7.33 |
arrayVmpLastSweepArray Vmp (last sweep)
- Description: Vmp (last sweep)
- Scaling Factor: 1.0
- Units: V
- Range: [-10, 650.0]
- Modbus address: 0x003dro DisplayString .1.3.6.1.4.1.33333.7.34 |
arrayVocLastSweepArray Voc (last sweep)
- Description: Voc (last sweep)
- Scaling Factor: 1.0
- Units: V
- Range: [-10, 650.0]
- Modbus address: 0x003ero DisplayString .1.3.6.1.4.1.33333.7.35 |
batteryVoltageBattery Voltage
- Description: Battery voltage
- Scaling Factor: 1.0
- Units: V
- Range: [-10, 80]
- Modbus address: 0x0018ro DisplayString .1.3.6.1.4.1.33333.7.36 |
batteryVoltageSlowBattery Voltage(slow)
- Description: Battery voltage(slow)
- Scaling Factor: 1.0
- Units: V
- Range: [-10, 80]
- Modbus address: 0x0026ro DisplayString .1.3.6.1.4.1.33333.7.37 |
batteryTerminalVoltageBattery Terminal Voltage
- Description: Battery Terminal Voltage
- Scaling Factor: 1.0
- Units: V
- Range: [-10, 80]
- Modbus address: 0x0019ro DisplayString .1.3.6.1.4.1.33333.7.38 |
batterySenseVoltageBattery Sense Voltage
- Description: Battery Sense Voltage
- Scaling Factor: 1.0
- Units: V
- Range: [-10, 80]
- Modbus address: 0x001aro DisplayString .1.3.6.1.4.1.33333.7.39 |
minBatteryVoltageSlowMin. Battery Voltage(slow)
- Description: Min. Battery voltage
- Scaling Factor: 1.0
- Units: V
- Range: [-10, 650.0]
- Modbus address: 0x0028ro DisplayString .1.3.6.1.4.1.33333.7.40 |
maxBatteryVoltageSlowMax. Battery Voltage(slow)
- Description: Max. Battery voltage
- Scaling Factor: 1.0
- Units: V
- Range: [-10, 650.0]
- Modbus address: 0x0029ro DisplayString .1.3.6.1.4.1.33333.7.41 |
batteryCurrentBattery Current
- Description: Battery Current
- Scaling Factor: 1.0
- Units: A
- Range: [-10, 80]
- Modbus address: 0x001cro DisplayString .1.3.6.1.4.1.33333.7.42 |
batteryCurrentSlowBattery Current(slow)
- Description: Battery current(slow)
- Scaling Factor: 1.0
- Units: A
- Range: [-10, 80.0]
- Modbus address: 0x0027ro DisplayString .1.3.6.1.4.1.33333.7.43 |
outputPowerOutput Power
- Description: Output Power
- Scaling Factor: 1.0
- Units: W
- Range: [-10, 4000]
- Modbus address: 0x003aro DisplayString .1.3.6.1.4.1.33333.7.44 |
targetRegulationVoltageTarget Regulation Voltage
- Description: Target Voltage
- Scaling Factor: 1.0
- Units: V
- Range: [-10, 650.0]
- Modbus address: 0x0033ro DisplayString .1.3.6.1.4.1.33333.7.45 |
chargeStateCharge State
- Description: Charge State
- Modbus address: 0x0032ro ChargeStateEnum .1.3.6.1.4.1.33333.7.46 |
rtsTemperatureRTS Temperature
- Description: RTS Temp
- Scaling Factor: 1.0
- Units: C
- Range: [-40, 80]
- Modbus address: 0x0024ro DisplayString .1.3.6.1.4.1.33333.7.47 |
batteryTemperatureBattery Temperature
- Description: Batt. Temp
- Scaling Factor: 1.0
- Units: C
- Range: [-40, 80]
- Modbus address: 0x0025ro DisplayString .1.3.6.1.4.1.33333.7.48 |
heatsinkTemperatureHeatsink Temperature
- Description: HS Temp
- Scaling Factor: 1.0
- Units: C
- Range: [-40, 80]
- Modbus address: 0x0023ro DisplayString .1.3.6.1.4.1.33333.7.49 |
ahChargeResetableAh Charge Resetable
- Description: Ah Charge Resetable
- Scaling Factor: 1.0
- Units: Ah
- Range: [0.0, 5000]
- Modbus addresses: H=0x0034 L=0x0035ro DisplayString .1.3.6.1.4.1.33333.7.50 |
ahChargeTotalAh Charge Total
- Description: Ah Charge Total
- Scaling Factor: 1.0
- Units: Ah
- Range: [0.0, 5000]
- Modbus addresses: H=0x0036 L=0x0037ro DisplayString .1.3.6.1.4.1.33333.7.51 |
kwhChargeResetablekWh Charge Resetable
- Description: kWh Charge Resetable
- Scaling Factor: 1.0
- Units: kWh
- Range: [0.0, 65535.0]
- Modbus address: 0x0038ro DisplayString .1.3.6.1.4.1.33333.7.52 |
kwhChargeTotalkWh Charge Total
- Description: kWh Charge Total
- Scaling Factor: 1.0
- Units: kWh
- Range: [0.0, 65535.0]
- Modbus address: 0x0039ro DisplayString .1.3.6.1.4.1.33333.7.53 |
ledStateLED State
- Description: Control Mode
- Modbus address: 0x0031ro LedStateEnum .1.3.6.1.4.1.33333.7.54 |
faultsFaults
- Description: Faults
- Modbus addresses: H=0x002c L=0x002dro FaultsBitfield .1.3.6.1.4.1.33333.7.55 |
faultsDailyFaults Daily
- Description: Faults Daily
- Modbus addresses: H=0x0049 L=0x004aro FaultsDailyBitfield .1.3.6.1.4.1.33333.7.56 |
alarmsAlarms
- Description: Alarms
- Modbus addresses: H=0x002e L=0x002fro AlarmsBitfield .1.3.6.1.4.1.33333.7.57 |
alarmsDailyAlarms Daily
- Description: Alarms
- Modbus addresses: H=0x004b L=0x004cro AlarmsDailyBitfield .1.3.6.1.4.1.33333.7.58 |
hourmeterHourmeter
- Description: Hourmeter
- Scaling Factor: 1.0
- Units: hrs
- Range: [0.0, 50000.0]
- Modbus addresses: H=0x002a L=0x002bro Unsigned32 .1.3.6.1.4.1.33333.7.59 |
settingsSwitchesSettings Switches
- Description: Settings Switches
- Modbus address: 0x0030ro SettingsSwitchesEnum .1.3.6.1.4.1.33333.7.60 |
More MIBs from morningstar
Browse all morningstarMIBs →Standard SNMP MIB module defining data structures for C-PRODUCT-TRAP-MIB.
The GENSTAR MIB module facilitates SNMP-based monitoring and management of Morningstar GenStar solar charge controllers and inverters, exposing operational metrics such as battery voltage, current, state of charge, and system status via Modbus-to-SNMP translation.
The PROSTAR-MPPT MIB module enables SNMP-based monitoring and management of Morningstar Prostar Maximum Power Point Tracking (MPPT) solar charge controllers, exposing telemetry for photovoltaic array voltage, current, power output, battery bank status, and system efficiency metrics.
The PROSTAR-PWM MIB module enables SNMP-based monitoring and management of Morningstar Prostar Pulse Width Modulation (PWM) solar charge controllers, exposing device-specific telemetry such as battery voltage, charging current, solar input status, and internal temperature. It facilitates the collection of operational state data and alarm conditions for these specific solar power management devices within a networked infrastructure.
The SUNSAVER-MPPT MIB module enables SNMP-based monitoring and management of Morningstar SunSaver MPPT solar charge controllers, specifically facilitating the retrieval of photovoltaic system telemetry such as input/output voltage, current, power, and battery state-of-charge. This module supports the device's Meterbus interface (Type 5) to aggregate critical charging parameters for remote system health assessment and performance analysis.
The TRISTAR-MPPT MIB module enables SNMP-based monitoring and management of Morningstar TriStar-MPPT solar charge controllers, specifically exposing metrics for photovoltaic input voltage and current, battery bank status, and MPPT tracking efficiency. This module facilitates the collection of real-time operational data and alarm states required for remote system health assessment and performance analysis of solar power installations.