TRISTAR-MPPT
The TRISTAR-MPPT MIB module enables SNMP-based monitoring and management of Morningstar TriStar-MPPT solar charge controllers, specifically exposing metrics for photovoltaic input voltage and current, battery bank status, and MPPT tracking efficiency. This module facilitates the collection of real-time operational data and alarm states required for remote system health assessment and performance analysis of solar power installations.
Imported Objects
Objects
37 total| Object Name |
|---|
tristarmpptMorningstar Product: TriStar-MPPT
Device Type: 8
Device Model: 0
Meterbus Type: 4
Copyright (C) Morningstar Corporation (2019).
All Rights Reserved MODULE-IDENTITY .1.3.6.1.4.1.33333.2 |
subModelThe device's exact modelro DisplayString .1.3.6.1.4.1.33333.2.1 |
serialNumberDevice Serial Numberro DisplayString .1.3.6.1.4.1.33333.2.2 |
deviceVersionHardware and firmware versions: vHW1.HW2.FWro DisplayString .1.3.6.1.4.1.33333.2.3 |
arrayVoltageArray Voltage
- Description: Array Voltage
- Scaling Factor: 0.0054931640625
- Units: V
- Range: [-10, 180]
- Modbus address: 0x001bro Integer32 .1.3.6.1.4.1.33333.2.30 |
arrayCurrentArray Current
- Description: Array Current
- Scaling Factor: 0.00244140625
- Units: A
- Range: [-10, 80]
- Modbus address: 0x001dro Integer32 .1.3.6.1.4.1.33333.2.31 |
inputPowerInput Power
- Description: Input Power
- Scaling Factor: 0.10986328125
- Units: W
- Range: [-10, 5000]
- Modbus address: 0x003bro Integer32 .1.3.6.1.4.1.33333.2.32 |
arrayPmaxLastSweepArray Pmax(last sweep)
- Description: Pmax (last sweep)
- Scaling Factor: 0.10986328125
- Units: W
- Range: [-10, 5000]
- Modbus address: 0x003cro Integer32 .1.3.6.1.4.1.33333.2.33 |
arrayVmpLastSweepArray Vmp (last sweep)
- Description: Vmp (last sweep)
- Scaling Factor: 0.0054931640625
- Units: V
- Range: [-10, 180.0]
- Modbus address: 0x003dro Integer32 .1.3.6.1.4.1.33333.2.34 |
arrayVocLastSweepArray Voc (last sweep)
- Description: Voc (last sweep)
- Scaling Factor: 0.0054931640625
- Units: V
- Range: [-10, 180.0]
- Modbus address: 0x003ero Integer32 .1.3.6.1.4.1.33333.2.35 |
batteryVoltageBattery Voltage
- Description: Battery voltage
- Scaling Factor: 0.0054931640625
- Units: V
- Range: [-10, 180.0]
- Modbus address: 0x0018ro Integer32 .1.3.6.1.4.1.33333.2.36 |
batteryVoltageSlowBattery Voltage(slow)
- Description: Battery voltage(slow)
- Scaling Factor: 0.0054931640625
- Units: V
- Range: [-10, 180.0]
- Modbus address: 0x0026ro Integer32 .1.3.6.1.4.1.33333.2.37 |
batteryTerminalVoltageBattery Terminal Voltage
- Description: Battery Terminal Voltage
- Scaling Factor: 0.0054931640625
- Units: V
- Range: [-10, 180]
- Modbus address: 0x0019ro Integer32 .1.3.6.1.4.1.33333.2.38 |
batterySenseVoltageBattery Sense Voltage
- Description: Battery Sense Voltage
- Scaling Factor: 0.0054931640625
- Units: V
- Range: [-10, 180]
- Modbus address: 0x001aro Integer32 .1.3.6.1.4.1.33333.2.39 |
minBatteryVoltageSlowMin. Battery Voltage(slow)
- Description: Min. Battery voltage
- Scaling Factor: 0.0054931640625
- Units: V
- Range: [-10, 180.0]
- Modbus address: 0x0028ro Integer32 .1.3.6.1.4.1.33333.2.40 |
maxBatteryVoltageSlowMax. Battery Voltage(slow)
- Description: Max. Battery voltage
- Scaling Factor: 0.0054931640625
- Units: V
- Range: [-10, 180.0]
- Modbus address: 0x0029ro Integer32 .1.3.6.1.4.1.33333.2.41 |
batteryCurrentBattery Current
- Description: Battery Current
- Scaling Factor: 0.00244140625
- Units: A
- Range: [-10, 80]
- Modbus address: 0x001cro Integer32 .1.3.6.1.4.1.33333.2.42 |
batteryCurrentSlowBattery Current(slow)
- Description: Battery current(slow)
- Scaling Factor: 0.00244140625
- Units: A
- Range: [-10, 80.0]
- Modbus address: 0x0027ro Integer32 .1.3.6.1.4.1.33333.2.43 |
outputPowerOutput Power
- Description: Output Power
- Scaling Factor: 0.10986328125
- Units: W
- Range: [-10, 5000]
- Modbus address: 0x003aro Integer32 .1.3.6.1.4.1.33333.2.44 |
targetRegulationVoltageTarget Regulation Voltage
- Description: Target Voltage
- Scaling Factor: 0.0054931640625
- Units: V
- Range: [-10, 180.0]
- Modbus address: 0x0033ro Integer32 .1.3.6.1.4.1.33333.2.45 |
chargeStateCharge State
- Description: Charge State
- Modbus address: 0x0032ro ChargeStateEnum .1.3.6.1.4.1.33333.2.46 |
rtsTemperatureRTS Temperature
- Description: RTS Temp
- Scaling Factor: 1.0
- Units: C
- Range: [-40, 80]
- Modbus address: 0x0024ro Integer32 .1.3.6.1.4.1.33333.2.47 |
batteryTemperatureBattery Temperature
- Description: Batt. Temp
- Scaling Factor: 1.0
- Units: C
- Range: [-40, 80]
- Modbus address: 0x0025ro Integer32 .1.3.6.1.4.1.33333.2.48 |
heatsinkTemperatureHeatsink Temperature
- Description: HS Temp
- Scaling Factor: 1.0
- Units: C
- Range: [-40, 80]
- Modbus address: 0x0023ro Integer32 .1.3.6.1.4.1.33333.2.49 |
ahChargeResetableAh Charge Resetable
- Description: Ah Charge Resetable
- Scaling Factor: 0.1
- Units: Ah
- Range: [0.0, 5000]
- Modbus addresses: H=0x0034 L=0x0035ro Unsigned32 .1.3.6.1.4.1.33333.2.50 |
ahChargeTotalAh Charge Total
- Description: Ah Charge Total
- Scaling Factor: 0.1
- Units: Ah
- Range: [0.0, 5000]
- Modbus addresses: H=0x0036 L=0x0037ro Unsigned32 .1.3.6.1.4.1.33333.2.51 |
kwhChargeResetablekWh Charge Resetable
- Description: kWh Charge Resetable
- Scaling Factor: 0.1
- Units: kWh
- Range: [0.0, 65535.0]
- Modbus address: 0x0038ro Unsigned32 .1.3.6.1.4.1.33333.2.52 |
kwhChargeTotalkWh Charge Total
- Description: kWh Charge Total
- Scaling Factor: 1.0
- Units: kWh
- Range: [0.0, 65535.0]
- Modbus address: 0x0039ro Unsigned32 .1.3.6.1.4.1.33333.2.53 |
ledStateLED State
- Description: Control Mode
- Modbus address: 0x0031ro LedStateEnum .1.3.6.1.4.1.33333.2.54 |
faultsFaults
- Description: Faults
- Modbus address: 0x002cro FaultsBitfield .1.3.6.1.4.1.33333.2.55 |
faultsDailyFaults Daily
- Description: Faults Daily
- Modbus address: 0x0049ro FaultsDailyBitfield .1.3.6.1.4.1.33333.2.56 |
alarmsAlarms
- Description: Alarms
- Modbus addresses: H=0x002e L=0x002fro AlarmsBitfield .1.3.6.1.4.1.33333.2.57 |
alarmsDailyAlarms Daily
- Description: Alarms
- Modbus addresses: H=0x004b L=0x004cro AlarmsDailyBitfield .1.3.6.1.4.1.33333.2.58 |
hourmeterHourmeter
- Description: Hourmeter
- Scaling Factor: 1.0
- Units: hrs
- Range: [0.0, 50000.0]
- Modbus addresses: H=0x002a L=0x002bro Unsigned32 .1.3.6.1.4.1.33333.2.59 |
settingsSwitchesSettings Switches
- Description: Settings Switches
- Modbus address: 0x0030ro SettingsSwitchesEnum .1.3.6.1.4.1.33333.2.60 |
processorAVersionProcessor A Version
- Description: Processor A Software Version
- Scaling Factor: 1.0
- Range: [0, 65535]
- Modbus address: 0x0004ro Integer32 .1.3.6.1.4.1.33333.2.61 |
processorBVersionProcessor B Version
- Description: Processor B Software Version
- Scaling Factor: 1.0
- Range: [0, 65535]
- Modbus address: 0x1000ro Integer32 .1.3.6.1.4.1.33333.2.62 |
More MIBs from morningstar
Browse all morningstarMIBs →Standard SNMP MIB module defining data structures for C-PRODUCT-TRAP-MIB.
The GENSTAR MIB module facilitates SNMP-based monitoring and management of Morningstar GenStar solar charge controllers and inverters, exposing operational metrics such as battery voltage, current, state of charge, and system status via Modbus-to-SNMP translation.
The PROSTAR-MPPT MIB module enables SNMP-based monitoring and management of Morningstar Prostar Maximum Power Point Tracking (MPPT) solar charge controllers, exposing telemetry for photovoltaic array voltage, current, power output, battery bank status, and system efficiency metrics.
The PROSTAR-PWM MIB module enables SNMP-based monitoring and management of Morningstar Prostar Pulse Width Modulation (PWM) solar charge controllers, exposing device-specific telemetry such as battery voltage, charging current, solar input status, and internal temperature. It facilitates the collection of operational state data and alarm conditions for these specific solar power management devices within a networked infrastructure.
The SUNSAVER-MPPT MIB module enables SNMP-based monitoring and management of Morningstar SunSaver MPPT solar charge controllers, specifically facilitating the retrieval of photovoltaic system telemetry such as input/output voltage, current, power, and battery state-of-charge. This module supports the device's Meterbus interface (Type 5) to aggregate critical charging parameters for remote system health assessment and performance analysis.
The TRISTAR-MPPT-600V MIB module enables SNMP-based monitoring and management of Morningstar TriStar-MPPT-600V solar charge controllers, specifically exposing photovoltaic input/output parameters such as array voltage, current, power, and MPPT tracking status. It facilitates the collection of real-time telemetry and operational counters required for remote system diagnostics and performance verification of the 600V DC solar charging infrastructure.