TRISTAR
The TRISTAR MIB module enables SNMP-based monitoring and management of Morningstar TriStar solar charge controllers, providing access to device-specific operational metrics such as battery voltage, charging current, load status, and system error states.
Imported Objects
Objects
26 total| Object Name |
|---|
tristarMorningstar Product: TriStar
Device Type: 2
Device Model: 0
Meterbus Type: 0
Copyright (C) Morningstar Corporation (2019).
All Rights Reserved MODULE-IDENTITY .1.3.6.1.4.1.33333.8 |
subModelThe device's exact modelro DisplayString .1.3.6.1.4.1.33333.8.1 |
serialNumberDevice Serial Numberro DisplayString .1.3.6.1.4.1.33333.8.2 |
deviceVersionHardware and firmware versions: vHW1.HW2.FWro DisplayString .1.3.6.1.4.1.33333.8.3 |
batteryVoltageBattery Voltage
- Description: Battery voltage
- Scaling Factor: 0.002950042724609375
- Units: V
- Range: [0.0, 80.0]
- Modbus address: 0x0008ro Unsigned32 .1.3.6.1.4.1.33333.8.30 |
batterySenseVoltageBattery Sense Voltage
- Description: Battery Sense Voltage
- Scaling Factor: 0.002950042724609375
- Units: V
- Range: [0, 80]
- Modbus address: 0x0009ro Unsigned32 .1.3.6.1.4.1.33333.8.31 |
arrayloadVoltageArray/Load Voltage
- Description: Array/Load Voltage
- Scaling Factor: 0.00424652099609375
- Units: V
- Range: [0, 80]
- Modbus address: 0x000Aro Unsigned32 .1.3.6.1.4.1.33333.8.32 |
chargeCurrentCharge Current
- Description: Charge Current
- Scaling Factor: 0.002034515380859375
- Units: A
- Range: [0, 60]
- Modbus address: 0x000Bro Unsigned32 .1.3.6.1.4.1.33333.8.33 |
loadCurrentLoad Current
- Description: Load Current
- Scaling Factor: 0.00966400146484375
- Units: A
- Range: [0, 60]
- Modbus address: 0x000Cro Unsigned32 .1.3.6.1.4.1.33333.8.34 |
batteryVoltageSlowBattery Voltage (Slow)
- Description: Battery Voltage (Slow)
- Scaling Factor: 0.002950042724609375
- Units: V
- Range: [0, 80]
- Modbus address: 0x000Dro Unsigned32 .1.3.6.1.4.1.33333.8.35 |
heatsinkTemperatureHeatsink Temperature
- Description: Heatsink Temperature
- Scaling Factor: 1.0
- Units: deg C
- Range: [-40, 120]
- Modbus address: 0x000Ero Integer32 .1.3.6.1.4.1.33333.8.36 |
batteryTemperatureBattery Temperature
- Description: Battery Temperature
- Scaling Factor: 1.0
- Units: deg C
- Range: [-40, 120]
- Modbus address: 0x000Fro Integer32 .1.3.6.1.4.1.33333.8.37 |
targetVoltageTarget Voltage
- Description: Target Regulation Voltage
- Scaling Factor: 0.002950042724609375
- Units: V
- Range: [0.0, 80.0]
- Modbus address: 0x0010ro Unsigned32 .1.3.6.1.4.1.33333.8.38 |
ahResettableAh (Resettable)
- Description: Ah (Resettable)
- Scaling Factor: 0.1
- Units: Ah
- Range: [0.0, 50000.0]
- Modbus addresses: H=0x0011 L=0x0012ro Unsigned32 .1.3.6.1.4.1.33333.8.39 |
ahTotalAh (Total)
- Description: Ah (Total)
- Scaling Factor: 0.1
- Units: Ah
- Range: [0.0, 50000.0]
- Modbus addresses: H=0x0013 L=0x0014ro Unsigned32 .1.3.6.1.4.1.33333.8.40 |
hourmeterHourmeter
- Description: Hourmeter
- Scaling Factor: 1.0
- Units: hrs
- Range: [0.0, 50000.0]
- Modbus addresses: H=0x0015 L=0x0016ro Unsigned32 .1.3.6.1.4.1.33333.8.41 |
alarmsAlarms
- Description: Alarms
- Modbus addresses: H=0x001D L=0x0017ro AlarmsBitfield .1.3.6.1.4.1.33333.8.42 |
faultsFaults
- Description: Faults
- Modbus address: 0x0018ro FaultsBitfield .1.3.6.1.4.1.33333.8.43 |
settingsSwitchesSettings Switches
- Description: Settings Switches
- Modbus address: 0x0019ro SettingsSwitchesEnum .1.3.6.1.4.1.33333.8.44 |
controlModeControl Mode
- Description: Control Mode
- Modbus address: 0x001Aro ControlModeEnum .1.3.6.1.4.1.33333.8.45 |
controlStateControl State
- Description: Control State
- Modbus address: 0x001Bro ControlStateEnum .1.3.6.1.4.1.33333.8.46 |
loadStateLoad State
- Description: Load State
- Modbus address: 0x001Bro LoadStateEnum .1.3.6.1.4.1.33333.8.47 |
pwmDutyCyclePWM Duty Cycle
- Description: PWM Duty Cycle
- Scaling Factor: 0.392156862745098
- Units: %
- Range: [0.0, 100.0]
- Modbus address: 0x001Cro Unsigned32 .1.3.6.1.4.1.33333.8.48 |
kilowattHoursKilowatt Hours
- Description: Kilowatt Hours
- Scaling Factor: 1.0
- Units: kWh
- Range: [0.0, 5000.0]
- Modbus address: 0x001Ero Unsigned32 .1.3.6.1.4.1.33333.8.49 |
minimumBatteryVoltageMinimum Battery Voltage
- Description: Minimum Battery Voltage
- Scaling Factor: 0.002950042724609375
- Units: V
- Range: [0.0, 80.0]
- Modbus address: 0x001Fro Unsigned32 .1.3.6.1.4.1.33333.8.50 |
maximumBatteryVoltageMaximum Battery Voltage
- Description: Maximum Battery Voltage
- Scaling Factor: 0.002950042724609375
- Units: V
- Range: [0.0, 80.0]
- Modbus address: 0x0020ro Unsigned32 .1.3.6.1.4.1.33333.8.51 |
More MIBs from morningstar
Browse all morningstarMIBs →Standard SNMP MIB module defining data structures for C-PRODUCT-TRAP-MIB.
The GENSTAR MIB module facilitates SNMP-based monitoring and management of Morningstar GenStar solar charge controllers and inverters, exposing operational metrics such as battery voltage, current, state of charge, and system status via Modbus-to-SNMP translation.
The PROSTAR-MPPT MIB module enables SNMP-based monitoring and management of Morningstar Prostar Maximum Power Point Tracking (MPPT) solar charge controllers, exposing telemetry for photovoltaic array voltage, current, power output, battery bank status, and system efficiency metrics.
The PROSTAR-PWM MIB module enables SNMP-based monitoring and management of Morningstar Prostar Pulse Width Modulation (PWM) solar charge controllers, exposing device-specific telemetry such as battery voltage, charging current, solar input status, and internal temperature. It facilitates the collection of operational state data and alarm conditions for these specific solar power management devices within a networked infrastructure.
The SUNSAVER-MPPT MIB module enables SNMP-based monitoring and management of Morningstar SunSaver MPPT solar charge controllers, specifically facilitating the retrieval of photovoltaic system telemetry such as input/output voltage, current, power, and battery state-of-charge. This module supports the device's Meterbus interface (Type 5) to aggregate critical charging parameters for remote system health assessment and performance analysis.
The TRISTAR-MPPT MIB module enables SNMP-based monitoring and management of Morningstar TriStar-MPPT solar charge controllers, specifically exposing metrics for photovoltaic input voltage and current, battery bank status, and MPPT tracking efficiency. This module facilitates the collection of real-time operational data and alarm states required for remote system health assessment and performance analysis of solar power installations.