Home/Catalog/TRISTAR

TRISTAR

AI MIB Summary

The TRISTAR MIB module enables SNMP-based monitoring and management of Morningstar TriStar solar charge controllers, providing access to device-specific operational metrics such as battery voltage, charging current, load status, and system error states.

Morningstar Product: TriStar Device Type: 2 Device Model: 0 Meterbus Type: 0 Copyright (C) Morningstar Corporation (2019). All Rights Reserved
Main OID:
tristar.1.3.6.1.4.1.33333.8
26
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

26 total
Object Name
tristarMorningstar Product: TriStar Device Type: 2 Device Model: 0 Meterbus Type: 0 Copyright (C) Morningstar Corporation (2019). All Rights Reserved
MODULE-IDENTITY
.1.3.6.1.4.1.33333.8
subModelThe device's exact modelro
DisplayString
.1.3.6.1.4.1.33333.8.1
serialNumberDevice Serial Numberro
DisplayString
.1.3.6.1.4.1.33333.8.2
deviceVersionHardware and firmware versions: vHW1.HW2.FWro
DisplayString
.1.3.6.1.4.1.33333.8.3
batteryVoltageBattery Voltage - Description: Battery voltage - Scaling Factor: 0.002950042724609375 - Units: V - Range: [0.0, 80.0] - Modbus address: 0x0008ro
Unsigned32
.1.3.6.1.4.1.33333.8.30
batterySenseVoltageBattery Sense Voltage - Description: Battery Sense Voltage - Scaling Factor: 0.002950042724609375 - Units: V - Range: [0, 80] - Modbus address: 0x0009ro
Unsigned32
.1.3.6.1.4.1.33333.8.31
arrayloadVoltageArray/Load Voltage - Description: Array/Load Voltage - Scaling Factor: 0.00424652099609375 - Units: V - Range: [0, 80] - Modbus address: 0x000Aro
Unsigned32
.1.3.6.1.4.1.33333.8.32
chargeCurrentCharge Current - Description: Charge Current - Scaling Factor: 0.002034515380859375 - Units: A - Range: [0, 60] - Modbus address: 0x000Bro
Unsigned32
.1.3.6.1.4.1.33333.8.33
loadCurrentLoad Current - Description: Load Current - Scaling Factor: 0.00966400146484375 - Units: A - Range: [0, 60] - Modbus address: 0x000Cro
Unsigned32
.1.3.6.1.4.1.33333.8.34
batteryVoltageSlowBattery Voltage (Slow) - Description: Battery Voltage (Slow) - Scaling Factor: 0.002950042724609375 - Units: V - Range: [0, 80] - Modbus address: 0x000Dro
Unsigned32
.1.3.6.1.4.1.33333.8.35
heatsinkTemperatureHeatsink Temperature - Description: Heatsink Temperature - Scaling Factor: 1.0 - Units: deg C - Range: [-40, 120] - Modbus address: 0x000Ero
Integer32
.1.3.6.1.4.1.33333.8.36
batteryTemperatureBattery Temperature - Description: Battery Temperature - Scaling Factor: 1.0 - Units: deg C - Range: [-40, 120] - Modbus address: 0x000Fro
Integer32
.1.3.6.1.4.1.33333.8.37
targetVoltageTarget Voltage - Description: Target Regulation Voltage - Scaling Factor: 0.002950042724609375 - Units: V - Range: [0.0, 80.0] - Modbus address: 0x0010ro
Unsigned32
.1.3.6.1.4.1.33333.8.38
ahResettableAh (Resettable) - Description: Ah (Resettable) - Scaling Factor: 0.1 - Units: Ah - Range: [0.0, 50000.0] - Modbus addresses: H=0x0011 L=0x0012ro
Unsigned32
.1.3.6.1.4.1.33333.8.39
ahTotalAh (Total) - Description: Ah (Total) - Scaling Factor: 0.1 - Units: Ah - Range: [0.0, 50000.0] - Modbus addresses: H=0x0013 L=0x0014ro
Unsigned32
.1.3.6.1.4.1.33333.8.40
hourmeterHourmeter - Description: Hourmeter - Scaling Factor: 1.0 - Units: hrs - Range: [0.0, 50000.0] - Modbus addresses: H=0x0015 L=0x0016ro
Unsigned32
.1.3.6.1.4.1.33333.8.41
alarmsAlarms - Description: Alarms - Modbus addresses: H=0x001D L=0x0017ro
AlarmsBitfield
.1.3.6.1.4.1.33333.8.42
faultsFaults - Description: Faults - Modbus address: 0x0018ro
FaultsBitfield
.1.3.6.1.4.1.33333.8.43
settingsSwitchesSettings Switches - Description: Settings Switches - Modbus address: 0x0019ro
SettingsSwitchesEnum
.1.3.6.1.4.1.33333.8.44
controlModeControl Mode - Description: Control Mode - Modbus address: 0x001Aro
ControlModeEnum
.1.3.6.1.4.1.33333.8.45
controlStateControl State - Description: Control State - Modbus address: 0x001Bro
ControlStateEnum
.1.3.6.1.4.1.33333.8.46
loadStateLoad State - Description: Load State - Modbus address: 0x001Bro
LoadStateEnum
.1.3.6.1.4.1.33333.8.47
pwmDutyCyclePWM Duty Cycle - Description: PWM Duty Cycle - Scaling Factor: 0.392156862745098 - Units: % - Range: [0.0, 100.0] - Modbus address: 0x001Cro
Unsigned32
.1.3.6.1.4.1.33333.8.48
kilowattHoursKilowatt Hours - Description: Kilowatt Hours - Scaling Factor: 1.0 - Units: kWh - Range: [0.0, 5000.0] - Modbus address: 0x001Ero
Unsigned32
.1.3.6.1.4.1.33333.8.49
minimumBatteryVoltageMinimum Battery Voltage - Description: Minimum Battery Voltage - Scaling Factor: 0.002950042724609375 - Units: V - Range: [0.0, 80.0] - Modbus address: 0x001Fro
Unsigned32
.1.3.6.1.4.1.33333.8.50
maximumBatteryVoltageMaximum Battery Voltage - Description: Maximum Battery Voltage - Scaling Factor: 0.002950042724609375 - Units: V - Range: [0.0, 80.0] - Modbus address: 0x0020ro
Unsigned32
.1.3.6.1.4.1.33333.8.51
TRISTAR - SNMP MIB Reference | MIBs Explorer