Home/Catalog/TRISTAR

TRISTAR

AI MIB Summary

The TRISTAR MIB module enables SNMP-based monitoring and management of Morningstar TriStar solar charge controllers, providing access to device-specific operational metrics such as battery voltage, charging current, load status, and system error states.

Morningstar Product: TriStar Device Type: 2 Device Model: 0 Meterbus Type: 0 Copyright (C) Morningstar Corporation (2019). All Rights Reserved
Main OID:
tristar.1.3.6.1.4.1.33333.8
26
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

26 total
Object Name
tristarMorningstar Product: TriStar Device Type: 2 Device Model: 0 Meterbus Type: 0 Copyright (C) Morningstar Corporation (2019). All Rights Reserved
MODULE-IDENTITY
.1.3.6.1.4.1.33333.8
subModelThe device's exact modelro
DisplayString
.1.3.6.1.4.1.33333.8.1
serialNumberDevice Serial Numberro
DisplayString
.1.3.6.1.4.1.33333.8.2
deviceVersionHardware and firmware versions: vHW1.HW2.FWro
DisplayString
.1.3.6.1.4.1.33333.8.3
batteryVoltageBattery Voltage - Description: Battery voltage - Scaling Factor: 0.002950042724609375 - Units: V - Range: [0.0, 80.0] - Modbus address: 0x0008ro
Unsigned32
.1.3.6.1.4.1.33333.8.30
batterySenseVoltageBattery Sense Voltage - Description: Battery Sense Voltage - Scaling Factor: 0.002950042724609375 - Units: V - Range: [0, 80] - Modbus address: 0x0009ro
Unsigned32
.1.3.6.1.4.1.33333.8.31
arrayloadVoltageArray/Load Voltage - Description: Array/Load Voltage - Scaling Factor: 0.00424652099609375 - Units: V - Range: [0, 80] - Modbus address: 0x000Aro
Unsigned32
.1.3.6.1.4.1.33333.8.32
chargeCurrentCharge Current - Description: Charge Current - Scaling Factor: 0.002034515380859375 - Units: A - Range: [0, 60] - Modbus address: 0x000Bro
Unsigned32
.1.3.6.1.4.1.33333.8.33
loadCurrentLoad Current - Description: Load Current - Scaling Factor: 0.00966400146484375 - Units: A - Range: [0, 60] - Modbus address: 0x000Cro
Unsigned32
.1.3.6.1.4.1.33333.8.34
batteryVoltageSlowBattery Voltage (Slow) - Description: Battery Voltage (Slow) - Scaling Factor: 0.002950042724609375 - Units: V - Range: [0, 80] - Modbus address: 0x000Dro
Unsigned32
.1.3.6.1.4.1.33333.8.35
heatsinkTemperatureHeatsink Temperature - Description: Heatsink Temperature - Scaling Factor: 1.0 - Units: deg C - Range: [-40, 120] - Modbus address: 0x000Ero
Integer32
.1.3.6.1.4.1.33333.8.36
batteryTemperatureBattery Temperature - Description: Battery Temperature - Scaling Factor: 1.0 - Units: deg C - Range: [-40, 120] - Modbus address: 0x000Fro
Integer32
.1.3.6.1.4.1.33333.8.37
targetVoltageTarget Voltage - Description: Target Regulation Voltage - Scaling Factor: 0.002950042724609375 - Units: V - Range: [0.0, 80.0] - Modbus address: 0x0010ro
Unsigned32
.1.3.6.1.4.1.33333.8.38
ahResettableAh (Resettable) - Description: Ah (Resettable) - Scaling Factor: 0.1 - Units: Ah - Range: [0.0, 50000.0] - Modbus addresses: H=0x0011 L=0x0012ro
Unsigned32
.1.3.6.1.4.1.33333.8.39
ahTotalAh (Total) - Description: Ah (Total) - Scaling Factor: 0.1 - Units: Ah - Range: [0.0, 50000.0] - Modbus addresses: H=0x0013 L=0x0014ro
Unsigned32
.1.3.6.1.4.1.33333.8.40
hourmeterHourmeter - Description: Hourmeter - Scaling Factor: 1.0 - Units: hrs - Range: [0.0, 50000.0] - Modbus addresses: H=0x0015 L=0x0016ro
Unsigned32
.1.3.6.1.4.1.33333.8.41
alarmsAlarms - Description: Alarms - Modbus addresses: H=0x001D L=0x0017ro
AlarmsBitfield
.1.3.6.1.4.1.33333.8.42
faultsFaults - Description: Faults - Modbus address: 0x0018ro
FaultsBitfield
.1.3.6.1.4.1.33333.8.43
settingsSwitchesSettings Switches - Description: Settings Switches - Modbus address: 0x0019ro
SettingsSwitchesEnum
.1.3.6.1.4.1.33333.8.44
controlModeControl Mode - Description: Control Mode - Modbus address: 0x001Aro
ControlModeEnum
.1.3.6.1.4.1.33333.8.45
controlStateControl State - Description: Control State - Modbus address: 0x001Bro
ControlStateEnum
.1.3.6.1.4.1.33333.8.46
loadStateLoad State - Description: Load State - Modbus address: 0x001Bro
LoadStateEnum
.1.3.6.1.4.1.33333.8.47
pwmDutyCyclePWM Duty Cycle - Description: PWM Duty Cycle - Scaling Factor: 0.392156862745098 - Units: % - Range: [0.0, 100.0] - Modbus address: 0x001Cro
Unsigned32
.1.3.6.1.4.1.33333.8.48
kilowattHoursKilowatt Hours - Description: Kilowatt Hours - Scaling Factor: 1.0 - Units: kWh - Range: [0.0, 5000.0] - Modbus address: 0x001Ero
Unsigned32
.1.3.6.1.4.1.33333.8.49
minimumBatteryVoltageMinimum Battery Voltage - Description: Minimum Battery Voltage - Scaling Factor: 0.002950042724609375 - Units: V - Range: [0.0, 80.0] - Modbus address: 0x001Fro
Unsigned32
.1.3.6.1.4.1.33333.8.50
maximumBatteryVoltageMaximum Battery Voltage - Description: Maximum Battery Voltage - Scaling Factor: 0.002950042724609375 - Units: V - Range: [0.0, 80.0] - Modbus address: 0x0020ro
Unsigned32
.1.3.6.1.4.1.33333.8.51

More MIBs from morningstar

Browse all morningstarMIBs →
C-PRODUCT-TRAP-MIB

Standard SNMP MIB module defining data structures for C-PRODUCT-TRAP-MIB.

181 objects→
GENSTAR

The GENSTAR MIB module facilitates SNMP-based monitoring and management of Morningstar GenStar solar charge controllers and inverters, exposing operational metrics such as battery voltage, current, state of charge, and system status via Modbus-to-SNMP translation.

139 objects→
PROSTAR-MPPT

The PROSTAR-MPPT MIB module enables SNMP-based monitoring and management of Morningstar Prostar Maximum Power Point Tracking (MPPT) solar charge controllers, exposing telemetry for photovoltaic array voltage, current, power output, battery bank status, and system efficiency metrics.

60 objects→
PROSTAR-PWM

The PROSTAR-PWM MIB module enables SNMP-based monitoring and management of Morningstar Prostar Pulse Width Modulation (PWM) solar charge controllers, exposing device-specific telemetry such as battery voltage, charging current, solar input status, and internal temperature. It facilitates the collection of operational state data and alarm conditions for these specific solar power management devices within a networked infrastructure.

53 objects→
SUNSAVER-MPPT

The SUNSAVER-MPPT MIB module enables SNMP-based monitoring and management of Morningstar SunSaver MPPT solar charge controllers, specifically facilitating the retrieval of photovoltaic system telemetry such as input/output voltage, current, power, and battery state-of-charge. This module supports the device's Meterbus interface (Type 5) to aggregate critical charging parameters for remote system health assessment and performance analysis.

52 objects→
TRISTAR-MPPT

The TRISTAR-MPPT MIB module enables SNMP-based monitoring and management of Morningstar TriStar-MPPT solar charge controllers, specifically exposing metrics for photovoltaic input voltage and current, battery bank status, and MPPT tracking efficiency. This module facilitates the collection of real-time operational data and alarm states required for remote system health assessment and performance analysis of solar power installations.

44 objects→