Home/Catalog/TRIPPLITE-PRODUCTS

TRIPPLITE-PRODUCTS

This MIB module defines MIB objects which provide mechanisms for remote management capabilities of Tripp Lite PowerAlert and related software.
Main OID:
tlpProducts.1.3.6.1.4.1.850.1
1011
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

1011 total
Object Name
tlpProductsThis MIB module defines MIB objects which provide mechanisms for remote management capabilities of Tripp Lite PowerAlert and related software.
MODULE-IDENTITY
.1.3.6.1.4.1.850.1
tlpHardware
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1
tlpDevice
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.1
tlpDeviceNumDevicesThe number of devices that this agent is currently managing.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.1.1
tlpDeviceTableA list of device table entries. The number of entries is given by the value of tlpDevicesNumDevices.
SEQUENCE OF TlpDeviceEntry
.1.3.6.1.4.1.850.1.1.1.2
tlpDeviceEntryAn entry containing information applicable to a particular device managed by this agent.
TlpDeviceEntry
.1.3.6.1.4.1.850.1.1.1.2.1
tlpDeviceIndexThe table row index for the device.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.1.2.1.1
tlpDeviceRowStatusUsed with table edits to indicate the status of a given row in tlDeviceTable.ro
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.1.2.1.2
tlpDeviceTypeThe type of device. One of the appropriate hardware types: ups, pdu, envirosense, etc.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.1.2.1.3
tlpDeviceManufacturerThe name of the manufacturer.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.1.2.1.4
tlpDeviceModelThe model designation.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.1.2.1.5
tlpDeviceNameA user-supplied name for the device.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.1.2.1.6
tlpDeviceIDA user-supplied ID for the device.rw
INTEGER
.1.3.6.1.4.1.850.1.1.1.2.1.7
tlpDeviceLocationA user-supplied location for the device.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.1.2.1.8
tlpDeviceRegionA user-supplied region for the device.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.1.2.1.9
tlpDeviceStatusThe currently most critical alarm status for the device.ro
Enumeration
.1.3.6.1.4.1.850.1.1.1.2.1.10
tlpDeviceDetail
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.2
tlpDeviceIdentTableThe identity details of each device in device table. The number of entries is given by the value of tlpDevicesNumDevices.
SEQUENCE OF TlpDeviceIdentEntry
.1.3.6.1.4.1.850.1.1.2.1
tlpDeviceIdentEntryAn entry containing details for a particular device.
TlpDeviceIdentEntry
.1.3.6.1.4.1.850.1.1.2.1.1
tlpDeviceIdentProtocolThe Tripplite protocol used to communicate with the device.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.2.1.1.1
tlpDeviceIdentCommPortTypeThe type of communications port used to connect with the device.ro
Enumeration
.1.3.6.1.4.1.850.1.1.2.1.1.2
tlpDeviceIdentCommPortNameThe name of the communications port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.2.1.1.3
tlpDeviceIdentFirmwareVersionThe firmware version of the device.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.2.1.1.4
tlpDeviceIdentSerialNumThe serial number of the device.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.2.1.1.5
tlpDeviceIdentDateInstalledThe installation date for this device in the format of mm/dd/yyyy.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.2.1.1.6
tlpDeviceIdentHardwareVersionThe hardware revision of the device. This value will return ERROR_NO_SUCH_NAME if not supported by the device.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.2.1.1.7
tlpDeviceIdentCurrentUptimeThe device uptime since its last startup. The format of this value is a comma- delimited string representing days, hours and minutes. For example, the value of 123,4,5 represents 123 days, 4 hours and 5 minutes. This value will return ERROR_NO_SUCH_NAME if not supported by the device.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.2.1.1.8
tlpDeviceIdentTotalUptimeThe cumulative (total) uptime for the device. The format of this value is a comma- delimited string representing days, hours and minutes. For example, the value of 123,4,5 represents 123 days, 4 hours and 5 minutes. This value will return ERROR_NO_SUCH_NAME if not supported by the device.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.2.1.1.9
tlpDeviceTypes
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3
tlpUps
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.1
tlpUpsIdent
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.1.1
tlpUpsIdentNumUpsThe number of ups devices that this agent is currently managing.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.1.1
tlpUpsIdentTableThe identity details of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss.
SEQUENCE OF TlpUpsIdentEntry
.1.3.6.1.4.1.850.1.1.3.1.1.2
tlpUpsIdentEntryAn entry containing details for a particular ups.
TlpUpsIdentEntry
.1.3.6.1.4.1.850.1.1.3.1.1.2.1
tlpUpsIdentNumInputsThe number of input lines supported by the ups.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.1.2.1.1
tlpUpsIdentNumOutputsThe number of output lines supported by the ups.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.1.2.1.2
tlpUpsIdentNumBypassThe number of bypass lines supported by the ups.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.1.2.1.3
tlpUpsIdentNumPhasesThe number of phases supported by the ups.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.1.2.1.4
tlpUpsIdentNumOutletsThe number of receptacles supported by the ups.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.1.2.1.5
tlpUpsIdentNumOutletGroupsThe number of receptacle groups supported by the ups.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.1.2.1.6
tlpUpsIdentNumBatteryPacksThe number of battery packs, internal and external combined, supported by the ups.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.1.2.1.7
tlpUpsSupportsTableThe supported details of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss.
SEQUENCE OF TlpUpsSupportsEntry
.1.3.6.1.4.1.850.1.1.3.1.1.3
tlpUpsSupportsEntryAn entry containing supported details for a particular ups.
TlpUpsSupportsEntry
.1.3.6.1.4.1.850.1.1.3.1.1.3.1
tlpUpsSupportsEnergywiseIndicates whether the ups supports Cisco EnergyWise.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.1.3.1.1
tlpUpsSupportsRampShedIndicates whether the ups supports ramping and shedding.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.1.3.1.2
tlpUpsSupportsOutletGroupIndicates whether the ups supports outlet groups.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.1.3.1.3
tlpUpsSupportsOutletCurrentPowerIndicates whether the ups reports individual receptacle current and power measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpUpsOutletCurrent and tlpUpsOutletPower.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.1.3.1.4
tlpUpsSupportsOutletVoltageIndicates whether the ups reports individual receptacle voltage measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpUpsOutletVoltage.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.1.3.1.5
tlpUpsDevice
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.1.2
tlpUpsDeviceTableThe device details of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss.
SEQUENCE OF TlpUpsDeviceEntry
.1.3.6.1.4.1.850.1.1.3.1.2.1
tlpUpsDeviceEntryAn entry containing device details for a particular ups.
TlpUpsDeviceEntry
.1.3.6.1.4.1.850.1.1.3.1.2.1.1
tlpUpsDeviceMainLoadStateThe current state of the main output of the device.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.2.1.1.1
tlpUpsDeviceMainLoadControllableIndicates whether or not the main output is controllable, and whether the ups can be turned off and on.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.2.1.1.2
tlpUpsDeviceMainLoadCommandReading this value will always return 0. Setting this value to turnOff(1) will turn off the main output of the ups. Setting this value to turnOn(2) will turn on the main output of the ups. Setting this value to cycle(3) will turn off the main output, then turn it back on.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.2.1.1.3
tlpUpsDevicePowerOnDelayThe configurable delay value, which sets the amount of additional time a given device will wait before it connects to a valid AC source. By default the delay value is set to 0.rw
Integer32
.1.3.6.1.4.1.850.1.1.3.1.2.1.1.4
tlpUpsDeviceTestDateThe date of the last self-test run on the ups, in the format YYYY-MM-DD.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.2.1.1.5
tlpUpsDeviceTestResultsStatusThe result of the last self-test run on the ups.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.2.1.1.6
tlpUpsDeviceTemperatureCThe ambient temperature at or near the ups casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.ro
Integer32 UNITS "degrees Centigrade"
.1.3.6.1.4.1.850.1.1.3.1.2.1.1.7
tlpUpsDeviceTemperatureFThe ambient temperature at or near the ups casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.ro
Integer32 UNITS "degrees Farenheit"
.1.3.6.1.4.1.850.1.1.3.1.2.1.1.8
tlpUpsDetail
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.1.3
tlpUpsBattery
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.1.3.1
tlpUpsBatterySummaryTableThe battery system summary of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
SEQUENCE OF TlpUpsBatterySummaryEntry
.1.3.6.1.4.1.850.1.1.3.1.3.1.1
tlpUpsBatterySummaryEntryAn entry containing information applicable to a particular battery system managed by this agent.
TlpUpsBatterySummaryEntry
.1.3.6.1.4.1.850.1.1.3.1.3.1.1.1
tlpUpsBatteryStatusThe indication of the capacity remaining in the UPS system's batteries. A value of batteryNormal indicates that the remaining run-time is greater than tlpUpsConfigLowBattTime. A value of batteryLow indicates that the remaining battery run-time is less than or equal to tlpUpsConfigLowBattTime. A value of batteryDepleted indicates that the UPS will be unable to sustain the present load when and if the utility power is lost (including the possibility that the utility power is currently absent and the UPS is unable to sustain the output).ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.1
tlpUpsSecondsOnBatteryIf the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.ro
Unsigned32 UNITS "seconds"
.1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.2
tlpUpsEstimatedMinutesRemainingAn estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off.ro
Unsigned32 UNITS "minutes"
.1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.3
tlpUpsEstimatedChargeRemainingAn estimate of the battery charge remaining expressed as a percent of full charge.ro
INTEGER
.1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.4
tlpUpsBatteryRunTimeRemainingThe run time remaining before batteries are exhausted. If the device does not support run time remaining, then the agent reports ERROR_NO_SUCH_NAME.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.850.1.1.3.1.3.1.1.1.5
tlpUpsBatteryDetailTableThe battery detail of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
SEQUENCE OF TlpUpsBatteryDetailEntry
.1.3.6.1.4.1.850.1.1.3.1.3.1.2
tlpUpsBatteryDetailEntryAn entry containing information applicable to a particular battery system managed by this agent.
TlpUpsBatteryDetailEntry
.1.3.6.1.4.1.850.1.1.3.1.3.1.2.1
tlpUpsBatteryDetailVoltageThe magnitude of the present battery voltage.ro
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.1
tlpUpsBatteryDetailCurrentThe present battery current.ro
Unsigned32 UNITS "0.1 Amp DC"
.1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.2
tlpUpsBatteryDetailCapacityThe estimated remaining battery capacity expressed as a percent of full capacity.ro
INTEGER
.1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.3
tlpUpsBatteryDetailChargeDenotes the charge state of the battery.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.4
tlpUpsBatteryDetailChargerStatusThe status of the battery charger. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.3.1.2.1.5
tlpUpsBatteryPackIdentTableThe battery identification details for each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by upsIdentNumUps and the number of battery battery packs per each as reported by tlpUpsNumBatteryPacks.
SEQUENCE OF TlpUpsBatteryIdentEntry
.1.3.6.1.4.1.850.1.1.3.1.3.1.3
tlpUpsBatteryPackIdentEntryAn entry containing information applicable to a particular battery pack managed by this agent.
TlpUpsBatteryIdentEntry
.1.3.6.1.4.1.850.1.1.3.1.3.1.3.1
tlpUpsBatteryPackIdentIndexThe table row index for the ups battery pack.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.1
tlpUpsBatteryPackIdentManufacturerThe manufacturer of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.2
tlpUpsBatteryPackIdentModelThe model or device name of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.3
tlpUpsBatteryPackIdentSerialNumThe serial number of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.4
tlpUpsBatteryPackIdentFirmwareThe firmware of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.5
tlpUpsBatteryPackIdentSKUThe SKU of the battery pack. If the device does not support this value, then the agent reports ERROR_NO_SUCH_NAME.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.3.1.3.1.6
tlpUpsBatteryPackConfigTableThe battery configuration details for each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by upsIdentNumUps and the number of battery battery packs per each as reported by tlpUpsNumBatteryPacks.
SEQUENCE OF TlpUpsBatteryConfigEntry
.1.3.6.1.4.1.850.1.1.3.1.3.1.4
tlpUpsBatteryPackConfigEntryAn entry containing information applicable to a particular battery pack managed by this agent.
TlpUpsBatteryConfigEntry
.1.3.6.1.4.1.850.1.1.3.1.3.1.4.1
tlpUpsBatteryPackConfigChemistryThe type of battery pack.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.1
tlpUpsBatteryPackConfigStyleThe style of battery pack.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.2
tlpUpsBatteryPackConfigLocationThe location of the battery pack.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.3
tlpUpsBatteryPackConfigStringsThe number of series strings in parallel contained in the battery pack. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.4
tlpUpsBatteryPackConfigBatteriesPerStringThe number of battery per each string in the battery pack. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.5
tlpUpsBatteryPackConfigCellsPerBatteryThe number of cells per battery..ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.6
tlpUpsBatteryPackConfigNumBatteriesThe total number of batteries contained in the battery pack. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.7
tlpUpsBatteryPackConfigCapacityUnitsThe units of measurement used for tlpUpsBatteryPackConfigDesignCapacity and tlpUpsBatteryPackConfigCellCapacity. If supported, this value will report either mAHR(1), amps per hour, or mWhr(1), watts per hour. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.8
tlpUpsBatteryPackConfigDesignCapacityThe theoretical or nominal capacity of the battery pack in the measurement defined by tlpUpsBatteryPackConfigCapacityUnits. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.9
tlpUpsBatteryPackConfigCellCapacityThe capacity of the batteries in the measurement defined by tlpUpsBatteryPackConfigCapacityUnits. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.10
tlpUpsBatteryPackConfigMinCellVoltageThe minimum cell voltage for the batteries. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.11
tlpUpsBatteryPackConfigMaxCellVoltageThe maximum cell voltage for the batteries. If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.3.1.4.1.12
tlpUpsBatteryPackDetailTableThe details of each battery pack for each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss and battery packs managed by the agent as reported by tlpUpsIdentNumUps and tlpUpsIdentNumBatteryPacks.
SEQUENCE OF TlpUpsBatteryPackDetailEntry
.1.3.6.1.4.1.850.1.1.3.1.3.1.5
tlpUpsBatteryPackDetailEntryAn entry containing information applicable to a particular battery system managed by this agent.
TlpUpsBatteryPackDetailEntry
.1.3.6.1.4.1.850.1.1.3.1.3.1.5.1
tlpUpsBatteryPackDetailConditionThe condition of the battery. A bad battery should be replaced.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.1
tlpUpsBatteryPackDetailTemperatureCThe ambient temperature at or near the UPS Battery casing.ro
Unsigned32 UNITS "degrees Centigrade"
.1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.2
tlpUpsBatteryPackDetailTemperatureFThe ambient temperature at or near the UPS Battery casing.ro
Unsigned32 UNITS "0.1 degrees Farenheit"
.1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.3
tlpUpsBatteryPackDetailAgeThe age of the battery in years. This is equal to the current date minus tlpUpsBatteryPackIdentInstallDate.ro
Unsigned32 UNITS "0.1 Years"
.1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.4
tlpUpsBatteryPackDetailLastReplaceDateThe date when the batteries were last replaced in YYYYMMDD format.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.5
tlpUpsBatteryPackDetailNextReplaceDateThe date when the batteries should next be replaced in YYYYMMDD format.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.6
tlpUpsBatteryPackDetailCycleCountThe number of times the battery went into invert mode. This number is incremented by 1 each time the unit goes on battery mode (with the exception of Self Test mode). If the device does not support this value, then the agent will report ERROR_NO_SUCH_NAME.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.3.1.5.1.7
tlpUpsInput
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.1.3.2
tlpUpsInputTableThe input details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
SEQUENCE OF TlpUpsInputEntry
.1.3.6.1.4.1.850.1.1.3.1.3.2.1
tlpUpsInputEntryAn entry containing information applicable to all input lines per each ups managed by this agent.
TlpUpsInputEntry
.1.3.6.1.4.1.850.1.1.3.1.3.2.1.1
tlpUpsInputLineBadsA count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer. This count is incremented by one each time the input transitions from zero out-of-tolerance lines to one or more input lines out-of-tolerance. This value is not supported on all units. If the ups does not support this value, then the agent reports ERROR_NO_SUCH_NAME.ro
INTEGER
.1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.1
tlpUpsInputNominalVoltageThe nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.2
tlpUpsInputNominalFrequencyThe nominal value of the input line frequency. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.3
tlpUpsInputLowTransferVoltageThe minimum line voltage allowed before the ups system transfers to battery backup.ro
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.4
tlpUpsInputLowTransferVoltageLowerBoundThe lower boundary value of tlpUpsInputLowTransferVoltage as dictated by the hardware of the unit.ro
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.5
tlpUpsInputLowTransferVoltageUpperBoundThe upper boundary value of tlpUpsInputLowTransferVoltage as dictated by the hardware of the unit.ro
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.6
tlpUpsInputHighTransferVoltageThe maximum line voltage allowed before the ups system transfers to battery backup.ro
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.7
tlpUpsInputHighTransferVoltageLowerBoundThe lower boundary value of tlpUpsInputHighTransferVoltage as dictated by the hardware of the unit.ro
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.8
tlpUpsInputHighTransferVoltageUpperBoundThe upper boundary value of tlpUpsInputHighTransferVoltage as dictated by the hardware of the unit.ro
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.1.3.2.1.1.9
tlpUpsInputPhaseTableThe input phase details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps and tlpUpsIdentNumPhases.
SEQUENCE OF TlpUpsInputPhaseEntry
.1.3.6.1.4.1.850.1.1.3.1.3.2.2
tlpUpsInputPhaseEntryAn entry containing information applicable to a particular input phase managed by this agent.
TlpUpsInputPhaseEntry
.1.3.6.1.4.1.850.1.1.3.1.3.2.2.1
tlpUpsInputPhaseIndexThe table row index for the ups input phase.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.1
tlpUpsInputPhaseFrequencyThe present input frequency for a given input line.ro
Unsigned32 UNITS "0.1 Hertz"
.1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.2
tlpUpsInputPhaseVoltageThe magnitude of the present input voltage for a given input line.ro
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.3
tlpUpsInputPhaseVoltageMinThe minimum input voltage value since the last reset of this value for a given input line. If any value is written to either tlpUpsInputVoltageMin or tlpUpsInputVoltageMax, both will be reset to their appropriate minimum and maximum values.rw
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.4
tlpUpsInputPhaseVoltageMaxThe maximum input voltage value since the last reset of this value for a given input line. If any value is written to either tlpUpsInputVoltageMin or tlpUpsInputVoltageMax, both will be reset to their appropriate minimum and maximum values.rw
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.5
tlpUpsInputPhaseCurrentThe magnitude of the present input current.ro
Unsigned32 UNITS "0.01 Amp DC"
.1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.6
tlpUpsInputPhasePowerThe magnitude of the present input true power.ro
Unsigned32 UNITS "Watts"
.1.3.6.1.4.1.850.1.1.3.1.3.2.2.1.7
tlpUpsOutput
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.1.3.3
tlpUpsOutputTableThe output details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
SEQUENCE OF TlpUpsOutputEntry
.1.3.6.1.4.1.850.1.1.3.1.3.3.1
tlpUpsOutputEntryAn entry containing information applicable to a particular output line managed by this agent.
TlpUpsOutputEntry
.1.3.6.1.4.1.850.1.1.3.1.3.3.1.1
tlpUpsOutputSourceThe present source of output power. The enumeration none(2) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.3.3.1.1.1
tlpUpsOutputNominalVoltageThe nominal value of the output voltage. This value may not be supported on all models. If not supported, the agent reports ERROR_NO_SUCH_NAME.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.3.3.1.1.2
tlpUpsOutputFrequencyThe present output frequency. The output frequency on most ups devices is common across all output lines. Some ups devices, however, maintain the output frequency per each line. If a common frequency is supported by the ups, then this frequency will contain the common frequency value. If not supported, the agent reports ERROR_NO_SUCH_NAME.ro
Unsigned32 UNITS "0.1 Hertz"
.1.3.6.1.4.1.850.1.1.3.1.3.3.1.1.3
tlpUpsOutputLineTableThe output line details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
SEQUENCE OF TlpUpsOutputLineEntry
.1.3.6.1.4.1.850.1.1.3.1.3.3.2
tlpUpsOutputLineEntryAn entry containing information applicable to a particular output line managed by this agent.
TlpUpsOutputLineEntry
.1.3.6.1.4.1.850.1.1.3.1.3.3.2.1
tlpUpsOutputLineIndexThe table row index for the ups output line.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.1
tlpUpsOutputLineVoltageThe magnitude of the present output voltage for a given output line.ro
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.2
tlpUpsOutputLineCurrentThe present output current.ro
Unsigned32 UNITS "0.1 Amp"
.1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.3
tlpUpsOutputLinePowerThe present output true power.ro
Unsigned32 UNITS "Watts"
.1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.4
tlpUpsOutputLinePercentLoadThe percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA.ro
INTEGER
.1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.5
tlpUpsOutputLineFrequencyThe present output frequency on this output line. The output frequency on most ups devices is common across all output lines. Some ups devices, however, maintain the output frequency per each line. If a per line frequency is supported by the ups, then this frequency value will reports the value of this line. If not supported, the agent reports ERROR_NO_SUCH_NAME.ro
Unsigned32 UNITS "0.1 Hertz"
.1.3.6.1.4.1.850.1.1.3.1.3.3.2.1.6
tlpUpsBypass
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.1.3.4
tlpUpsBypassTableThe bypass details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
SEQUENCE OF TlpUpsBypassEntry
.1.3.6.1.4.1.850.1.1.3.1.3.4.1
tlpUpsBypassEntryAn entry containing information applicable to all input lines per each ups managed by this agent.
TlpUpsBypassEntry
.1.3.6.1.4.1.850.1.1.3.1.3.4.1.1
tlpUpsBypassFrequencyThe present bypass frequency.ro
Unsigned32 UNITS "0.1 Hertz"
.1.3.6.1.4.1.850.1.1.3.1.3.4.1.1.1
tlpUpsBypassLineTableThe bypass line details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
SEQUENCE OF TlpUpsBypassLineEntry
.1.3.6.1.4.1.850.1.1.3.1.3.4.2
tlpUpsBypassLineEntryAn entry containing information applicable to a particular bypass line managed by this agent.
TlpUpsBypassLineEntry
.1.3.6.1.4.1.850.1.1.3.1.3.4.2.1
tlpUpsBypassLineIndexThe bypass line identifier.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.3.4.2.1.1
tlpUpsBypassLineVoltageThe present bypass voltage.ro
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.1.3.4.2.1.2
tlpUpsBypassLineCurrentThe present bypass current.ro
Unsigned32 UNITS "0.1 Amp"
.1.3.6.1.4.1.850.1.1.3.1.3.4.2.1.3
tlpUpsBypassLinePowerThe present true power conveyed by the bypass.ro
Unsigned32 UNITS "Watts"
.1.3.6.1.4.1.850.1.1.3.1.3.4.2.1.4
tlpUpsOutlet
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.1.3.5
tlpUpsOutletTableThe details of each ups outlet in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
SEQUENCE OF TlpUpsOutletEntry
.1.3.6.1.4.1.850.1.1.3.1.3.5.1
tlpUpsOutletEntryAn entry containing information applicable to a particular outlet managed by this agent.
TlpUpsOutletEntry
.1.3.6.1.4.1.850.1.1.3.1.3.5.1.1
tlpUpsOutletIndexThe table row index for the ups outlet.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.1
tlpUpsOutletNameA user-definable string identifying the name of the outlet.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.2
tlpUpsOutletDescriptionA user-definable string identifying the device(s) connected to the given outlet.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.3
tlpUpsOutletStateThe current state of the outlet.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.4
tlpUpsOutletControllableDenotes whether this outlet is controllable.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.5
tlpUpsOutletCommandReading this value will always return 0. Setting this value to turnOff(1) will turn off the outlet. Setting this value to turnOn(2) will turn on the outlet. Setting this value to cycle(3) will turn the outlet off, then turn it back on.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.6
tlpUpsOutletVoltageThe magnitude of the present output voltage for a given outlet. If the voltage measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle voltage measurements is denoted by tlpUpsSupportsOutletVoltage.ro
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.7
tlpUpsOutletCurrentThe present output current, in hundreths of amps, of a given outlet. If the current measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle current measurements is denoted by tlpUpsSupportsCurrentPower.ro
Unsigned32 UNITS "0.01 RMS Amp"
.1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.8
tlpUpsOutletPowerThe output power of a given outlet. If the power measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle power measurements is denoted by tlpUpsSupportsCurrentPower.ro
Unsigned32 UNITS "Watts"
.1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.9
tlpUpsOutletRampActionThe ramp action to take on a given outlet when powering on the device. If this receptacle is not controllable, as denoted by tlpUpsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.10
tlpUpsOutletRampDelayThe number of seconds to delay before powering on the given outlet. If this receptacle is not controllable, as denoted by tlpUpsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.rw
Integer32 UNITS "seconds"
.1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.11
tlpUpsOutletShedActionThe shed action to take on a given outlet when powering off the device. If this receptacle is not controllable, as denoted by tlpUpsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.12
tlpUpsOutletShedDelayThe number of seconds to delay before powering off the given outlet. If this receptacle is not controllable, as denoted by tlpUpsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.rw
Integer32 UNITS "seconds"
.1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.13
tlpUpsOutletGroupThe tlpUpsOutletGroupIndex group index of the respective group to which the given outlet is assigned, or zero (0) if the given outlet is not grouped.rw
Integer32
.1.3.6.1.4.1.850.1.1.3.1.3.5.1.1.14
tlpUpsOutletGroupTableThe receptacle grouping details of each ups in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpUpsIdentNumOutletGroups per each device.
SEQUENCE OF TlpUpsOutletGroupEntry
.1.3.6.1.4.1.850.1.1.3.1.3.5.2
tlpUpsOutletGroupEntryAn entry containing information applicable to a particular outlet group managed by this agent.
TlpUpsOutletGroupEntry
.1.3.6.1.4.1.850.1.1.3.1.3.5.2.1
tlpUpsOutletGroupIndexThe table row index for the ups outlet group.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.1
tlpUpsOutletGroupRowStatusRow status for the tlpUpsOutletGroupTablerw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.2
tlpUpsOutletGroupNameThe name of this outlet group.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.3
tlpUpsOutletGroupDescriptionA description for this outlet group.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.4
tlpUpsOutletGroupStateThe current state of the outlet group. This value will report off(1) if all outlets in the group are off, on(2) if all outlets in the group are on, mixed(3) if some outlets in the group are off and others are on, or unknown(0) if the state of the outlets cannot be determined.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.5
tlpUpsOutletGroupCommandReading this value will always return 0. Setting this value to turnOff(1) will turn off every outlet associated with the group. Setting this value to turnOn(2) will turn on every outlet associated with the group. Setting this value to cycle(3) will turn off every outlet associated with the group, then turn each outlet back on.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.3.5.2.1.6
tlpUpsWatchdog
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.1.3.6
tlpUpsWatchdogTableThe watchdog details of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss.
SEQUENCE OF TlpUpsWatchdogEntry
.1.3.6.1.4.1.850.1.1.3.1.3.6.1
tlpUpsWatchdogEntryAn entry containing watchdog details for a particular ups.
TlpUpsWatchdogEntry
.1.3.6.1.4.1.850.1.1.3.1.3.6.1.1
tlpUpsWatchdogSupportedIndicates whether or not this ups supports a watchdog reboot.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.3.6.1.1.1
tlpUpsWatchdogSecsBeforeRebootThe maximum number of seconds that can expire between polls that the engine makes to the ups for data. If this time runs out, then the ups will cycle its outputs. Set this to zero to turns disable this feature.rw
Unsigned32
.1.3.6.1.4.1.850.1.1.3.1.3.6.1.1.2
tlpUpsControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.1.4
tlpUpsControlTableThe actionable controls for each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss.
SEQUENCE OF TlpUpsControlEntry
.1.3.6.1.4.1.850.1.1.3.1.4.1
tlpUpsControlEntryAn entry containing controls for a particular ups.
TlpUpsControlEntry
.1.3.6.1.4.1.850.1.1.3.1.4.1.1
tlpUpsControlSelfTestSet to TRUE to initiate a self test on the ups.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.4.1.1.1
tlpUpsControlRampSet to TRUE to initiate the pre-designated ramp sequence on the ups.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.4.1.1.2
tlpUpsControlShedSet to TRUE to initiate the pre-designated shed sequence on the ups.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.4.1.1.3
tlpUpsControlUpsOnSet to TRUE to turn the ups on.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.4.1.1.4
tlpUpsControlUpsOffSet to TRUE to turn the ups off.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.4.1.1.5
tlpUpsControlUpsRebootSet to TRUE to reboot the ups.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.1.4.1.1.6
tlpUpsControlBypassThis switches the ups in and out of bypass mode. This value returns the current bypass mode: disable(0) if the ups is not in bypass mode, enable(1) if the ups is in bypass mode. Set to disable(0) to exit bypass mode, or enable(1) to enter bypass mode. If switching bypass mode is not supported, this value will return ERROR_NO_SUCH_NAME.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.4.1.1.7
tlpUpsConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.1.5
tlpUpsConfigTableThe configuration details of each ups in the device table. This is a sparse dependent table, and will contain the number of entries based upon the number of upss managed by the agent as reported by tlpUpsIdentNumUps.
SEQUENCE OF TlpUpsConfigEntry
.1.3.6.1.4.1.850.1.1.3.1.5.1
tlpUpsConfigEntryAn entry containing information applicable to all input lines per each ups managed by this agent.
TlpUpsConfigEntry
.1.3.6.1.4.1.850.1.1.3.1.5.1.1
tlpUpsConfigInputVoltageThe nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned.rw
Unsigned32 UNITS "Volts"
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.1
tlpUpsConfigInputFrequencyThe nominal input frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2.rw
Unsigned32 UNITS "0.1 Hertz"
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.2
tlpUpsConfigOutputVoltageThe nominal value of the output voltage. This value may not be supported on all models. If not supported, the agent reports ERROR_NO_SUCH_NAME. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned.rw
Unsigned32 UNITS "Volts"
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.3
tlpUpsConfigOutputFrequencyThe nominal output frequency. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request will be rejected and the agent will respond with an appropriate error message.rw
Unsigned32 UNITS "0.1 Hertz"
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.4
tlpUpsConfigAudibleStatusThe requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self- describing. Setting this object to muted(3) when the audible alarm is sounding shall temporarily silence the alarm. It will remain muted until it would normally stop sounding and the value returned for read operations during this period shall equal muted(3). At the end of this period, the value shall revert to enabled(2). Writes of the value muted(3) when the audible alarm is not sounding shall be accepted but otherwise shall have no effect.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.5
tlpUpsConfigAutoBatteryTestWhen disabled(0), the ups will not perform an automatic battery selftest. When set to another value, the ups will perform an automatic selftest in the approximate period defined by each respective enumerated value. This feature is generally not recommended.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.6
tlpUpsConfigAutoRestartAfterShutdownWhen enabled(1), the ups should autorestart after a shutdown from battery mode if valid AC is applied. When disabled(0), the ups should not autorestart when AC is restored and instead power up into standby mode.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.7
tlpUpsConfigAutoRampOnTransitionWhen enabled(1), the ups should perform its preconfigured ramp sequence when valid AC is restored while in battery mode. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.8
tlpUpsConfigAutoShedOnTransitionWhen enabled(1), the ups should perform its preconfigured shed sequence when valid AC is lost causing the ups to enter battery mode. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.9
tlpUpsConfigBypassLowerLimitPercentThe lowest AC input voltage allowed to be output to the load while in bypass mode. This setting is expressed as a percentage from nominal voltage. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.rw
INTEGER (-20..-5) UNITS "percent"
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.10
tlpUpsConfigBypassUpperLimitPercentThe highest AC input voltage allowed to be output to the load while in bypass mode. This setting is expressed as a percentage from nominal voltage. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.rw
INTEGER
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.11
tlpUpsConfigBypassLowerLimitVoltageThe lowest AC input voltage allowed to be output to the load while in bypass mode. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "Volts"
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.12
tlpUpsConfigBypassUpperLimitVoltageThe highest AC input voltage allowed to be output to the load while in bypass mode. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "Volts"
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.13
tlpUpsConfigColdStartThis option enables or disables the ability to turn the ups on without AC supplied. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.14
tlpUpsConfigEconomicModeThe configurable economic mode options for the ups. The online(0) mode is the default configuration of most upss, which is synonymous as having the economic mode disabled. The economy(1) mode is the typical configuration to run in economy mode, which is synonymous as having the economic mode enabled. Constant50Hz(2) is a power strategy, which fixes the output frequency at 50Hz. Constant60Hz(3) is a power stragegy, which fixes the output frequency at 60Hz. ConstantAuto(4) regulates the output frequency at nominal input frequency. AutoAdaptive(5) mode will cause the ups to automatically switch between online(0), maximum quality, and economy(1), maximum efficiency, to improve efficiency during stable utility periods and improve output regulation during unstable utility periods. Not all values are supported by all upss. Most upss, if supportive of economic mode, only supports online(0) and economy(1). If the ups does not support economic mode, then this value will always return ERROR_NO_SUCH_NAME.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.15
tlpUpsConfigFaultActionDetermines the action to take if the output needs to be shut down due to a fault condition, limited by the type of fault incurred. When configured for bypass(0), the ups will go to bypass on a fault condition. When configured for standby(1), the ups will go to standby mode on a fault condition. Either configuration will be valid as long as AC input is within normal line voltage and frequency limits when the fault condition occurs. If the line is outside these limits, the ups will turn off. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.16
tlpUpsConfigOffModeThis option governs what mode the ups should go into when AC input is available, but the load is either off or not battery backed up. If this setting is configured for bypass(1), the intention is that any time the ups would normally go into standby mode, it would instead go into bypass mode. Note that this setting does not dictate the mode for fault conditions, which is governed by tlpUpsConfigFaultAction. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.17
tlpUpsConfigLineSensitivityAdjusts the AC line voltage sensitivity setting. If this value is not supported by the ups, then this value will always return ERROR_NO_SUCH_NAME.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.5.1.1.18
tlpUpsConfigAutoRestartTableThe configurable automatic restart options of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss. Not all options are available on all upss.
SEQUENCE OF TlpUpsConfigAutoRestartEntry
.1.3.6.1.4.1.850.1.1.3.1.5.2
tlpUpsConfigAutoRestartEntryAn entry containing configurable automatic restart options for a particular ups.
TlpUpsConfigAutoRestartEntry
.1.3.6.1.4.1.850.1.1.3.1.5.2.1
tlpUpsConfigAutoRestartInverterShutdownIf enabled(1) and the ups is turned off from invert mode (via user interaction), if line becomes valid, the ups will automatically go to line mode. If disabled(0), the ups will turn back on and go to standby mode instead.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.5.2.1.1
tlpUpsConfigAutoRestartDelayedWakeupIf enabled(1) and power fails during a DelayBeforeStartup and line remains invalid after the timeout expires, the ups will be set to turn back on automatically. If disabled(0), the ups will turn back on and go to standby mode instead.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.5.2.1.2
tlpUpsConfigAutoRestartLowVoltageCutoffIf enabled(1) and the ups is turned off from invert mode (via low voltage cutoff), if line becomes valid, the ups will automatically go to line mode. If disabled(0), the ups will turn back on and go to standby mode instead.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.5.2.1.3
tlpUpsConfigAutoRestartOverLoadIf enabled(1) and the ups is turned off from invert mode (via overload), if line becomes valid, the ups will automatically go to line mode. If disabled(0), the ups will turn back on and go to standby mode instead.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.5.2.1.4
tlpUpsConfigAutoRestartOverTemperatureIf enabled(1) and the ups is turned off from invert mode (via over temperature), if line becomes valid, the ups will automatically go to line mode. If disabled(0), the ups will turn back on and go to standby mode instead.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.1.5.2.1.5
tlpUpsConfigThresholdTableThe configurable threshold options of each ups in device table. This is a sparse dependent table, and will contain some subset of devices that are upss. Not all options are available on all upss.
SEQUENCE OF TlpUpsConfigThresholdEntry
.1.3.6.1.4.1.850.1.1.3.1.5.3
tlpUpsConfigThresholdEntryAn entry containing configurable threshold options for a particular ups.
TlpUpsConfigThresholdEntry
.1.3.6.1.4.1.850.1.1.3.1.5.3.1
tlpUpsConfigBatteryAgeThresholdThe number of months for a battery to be in service. The battery age alarm, tlpUpsAlarmBatteryAgeAboveThreshold, is triggered when the current date exceeds tlpUpsBatteryPackIdentInstallDate by tlpUpsConfigBatteryAgeThreshold months.rw
Unsigned32 UNITS "months"
.1.3.6.1.4.1.850.1.1.3.1.5.3.1.1
tlpUpsConfigLowBatteryThresholdThis value denotes the percentage of battery capacity remaining warning level. The low battery alarm, tlpUpsAlarmLowBattery, is triggered when tlpUpsEstimatedChargeRemaining drops below this value.rw
INTEGER
.1.3.6.1.4.1.850.1.1.3.1.5.3.1.2
tlpUpsConfigLowBatteryTimeThe value in seconds of tlpUpsEstimatedMinutesRemaining at which a lowBattery condition is declared. For agents which support only discrete (discontinuous) values, then the agent shall round up to the next supported value. If the requested value is larger than the largest supported value, then the largest supported value shall be selected.rw
Unsigned32 UNITS "seconds"
.1.3.6.1.4.1.850.1.1.3.1.5.3.1.3
tlpUpsConfigOverLoadThresholdThis value denotes the percentage of load at which the overload condition occurs. The overload alarm, tlpUpsAlarmOutputOverload, is triggered when the percentage of output load exceeds this value.rw
INTEGER
.1.3.6.1.4.1.850.1.1.3.1.5.3.1.4
tlpPdu
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.2
tlpPduIdent
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.2.1
tlpPduIdentNumPduThe number of pdu devices that this agent is currently managing.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.2.1.1
tlpPduIdentTableThe identity details of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus.
SEQUENCE OF TlpPduIdentEntry
.1.3.6.1.4.1.850.1.1.3.2.1.2
tlpPduIdentEntryAn entry containing details for a particular pdu.
TlpPduIdentEntry
.1.3.6.1.4.1.850.1.1.3.2.1.2.1
tlpPduIdentNumInputsThe number of input lines supported by the pdu.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.2.1.2.1.1
tlpPduIdentNumOutputsThe number of output lines supported by the pdu.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.2.1.2.1.2
tlpPduIdentNumPhasesThe number of phases supported by the pdu.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.2.1.2.1.3
tlpPduIdentNumOutletsThe number of receptacles supported by the pdu.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.2.1.2.1.4
tlpPduIdentNumOutletGroupsThe number of receptacle groups supported by the pdu.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.2.1.2.1.5
tlpPduIdentNumCircuitsThe number of circuits supported by the pdu.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.2.1.2.1.6
tlpPduIdentNumBreakersThe number of bank breakers supported by the pdu.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.2.1.2.1.7
tlpPduIdentNumHeatsinksThe number of heatsink thermistors supported by the pdu.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.2.1.2.1.8
tlpPduSupportsTableThe supported details of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus.
SEQUENCE OF TlpPduSupportsEntry
.1.3.6.1.4.1.850.1.1.3.2.1.3
tlpPduSupportsEntryAn entry containing supported details for a particular pdu.
TlpPduSupportsEntry
.1.3.6.1.4.1.850.1.1.3.2.1.3.1
tlpPduSupportsEnergywiseIndicates whether the pdu supports Cisco EnergyWise.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.2.1.3.1.1
tlpPduSupportsRampShedIndicates whether the pdu supports ramping and shedding.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.2.1.3.1.2
tlpPduSupportsOutletGroupIndicates whether the pdu supports outlet groups.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.2.1.3.1.3
tlpPduSupportsOutletCurrentPowerIndicates whether the pdu reports individual receptacle current and power measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpPduOutletCurrent and tlpPduOutletPower.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.2.1.3.1.4
tlpPduSupportsOutletVoltageIndicates whether the pdu reports individual receptacle voltage measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpPduOutletVoltage.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.2.1.3.1.5
tlpPduDisplayTableThe display details of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus.
SEQUENCE OF TlpPduDisplayEntry
.1.3.6.1.4.1.850.1.1.3.2.1.4
tlpPduDisplayEntryAn entry containing display details for a particular pdu.
TlpPduDisplayEntry
.1.3.6.1.4.1.850.1.1.3.2.1.4.1
tlpPduDisplaySchemeIndicates the display scheme of the LED display. The value schemeReverse(0) indicates the tricolor LED indicator uses an alternate pattern. The value schemeNormal(1) indicates the LED indicator uses the standard pattern. This value may not be supported on all models. If not supported, the value will always return schemeNormal(1).rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.1.4.1.1
tlpPduDisplayOrientationIndicates the physical orientation of the LED display. The value displayNormal(0) indicates the display is right-side-up (normal). The value displayReverse(1) indicates the display is upside-down. This value may not be supported on all models. If not supported, the value will always return displayNormal(0).rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.1.4.1.2
tlpPduDisplayAutoScrollIndicates whether the LED display automatically scrolls through displaying status values.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.1.4.1.3
tlpPduDisplayIntensityIndicates the intensity, as a percentage, of the LED display. The value intensity100(4) indicates the display is at 100% intensity. The other values indicate the display is at a lesser intensity based upon the respective percentage denoted.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.1.4.1.4
tlpPduDisplayUnitsIndicates the units of measurement displayed on the LED display. The value normal(0) indicates that a temperature value, for example, is displayed in degrees Farenheit. The value metric(1) indicates a temperature value is displayed in degrees Celsius.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.1.4.1.5
tlpPduDevice
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.2.2
tlpPduDeviceTableThe device details of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus.
SEQUENCE OF TlpPduDeviceEntry
.1.3.6.1.4.1.850.1.1.3.2.2.1
tlpPduDeviceEntryAn entry containing device details for a particular pdu.
TlpPduDeviceEntry
.1.3.6.1.4.1.850.1.1.3.2.2.1.1
tlpPduDeviceMainLoadStateThe current state of the main output of the device.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.2.1.1.1
tlpPduDeviceMainLoadControllableIndicates whether or not the main output is controllable, and whether the ups can be turned off and on.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.2.2.1.1.2
tlpPduDeviceMainLoadCommandReading this value will always return 0. Setting this value to turnOff(1) will turn off the main output of the ups. Setting this value to turnOn(2) will turn on the main output of the ups. Setting this value to cycle(3) will turn off the main output, then turn it back on.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.2.1.1.3
tlpPduDevicePowerOnDelayThe configurable delay value, which sets the amount of additional time a given device will wait before it connects to a valid AC source. By default the delay value is set to 0. For devices with multiple AC input sources, this delay only applies to the primary input source.rw
Integer32
.1.3.6.1.4.1.850.1.1.3.2.2.1.1.4
tlpPduDeviceTotalInputPowerRatingThe total input power rating of all phases on the device. This value may not be supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.ro
Integer32 UNITS "Watts"
.1.3.6.1.4.1.850.1.1.3.2.2.1.1.5
tlpPduDeviceTemperatureCThe ambient temperature at or near the PDU casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.ro
Integer32 UNITS "degrees Centigrade"
.1.3.6.1.4.1.850.1.1.3.2.2.1.1.6
tlpPduDeviceTemperatureFThe ambient temperature at or near the PDU casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.ro
Integer32 UNITS "degrees Farenheit"
.1.3.6.1.4.1.850.1.1.3.2.2.1.1.7
tlpPduDevicePhaseImbalanceThe percentage of imbalance of the three phases. This value is in the range from 0% imbalance to 100% imbalance. The lower the value, the better balanced the phases are. If all load is on a single phase, the imbalance is defined as 100%.ro
INTEGER
.1.3.6.1.4.1.850.1.1.3.2.2.1.1.8
tlpPduDeviceOutputPowerTotalThe AC output total power for all circuits.ro
Unsigned32 UNITS "Watts"
.1.3.6.1.4.1.850.1.1.3.2.2.1.1.9
tlpPduDeviceAggregatePowerFactorThe aggregrate power factor of all phases.ro
Unsigned32 UNITS "0.1 Watts"
.1.3.6.1.4.1.850.1.1.3.2.2.1.1.10
tlpPduDeviceOutputCurrentPrecisionOutput current is reported by tlpPduOutputCurrent, tlpPduOutputCurrentMin and tlpPduOutputCurrentMax. These values are all reported in hundredths (0.01A), which accommodates all models; however, on any given device the actual precision may vary. This value describes the actual precision, which can be used as a divisor against the output current values to obtain the true output current measurement. For example, if tlpPduOutputCurrent reports 530 and tlpPduDeviceOutputCurrentPrecision is tenths(1), then the actual output current is 5.3.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.2.1.1.11
tlpPduDetail
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.2.3
tlpPduInput
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.2.3.1
tlpPduInputTableThe input details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of pdus managed by the agent as reported by tlpPduIdentNumPdus.
SEQUENCE OF TlpPduInputEntry
.1.3.6.1.4.1.850.1.1.3.2.3.1.1
tlpPduInputEntryAn entry containing information applicable to a particular pdu managed by this agent.
TlpPduInputEntry
.1.3.6.1.4.1.850.1.1.3.2.3.1.1.1
tlpPduInputNominalVoltageThe nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.1
tlpPduInputNominalVoltagePhaseToPhaseThe nominal value of the input line voltage as measured from phase to phase. This value may not be supported on all models. If not supported, this value will always return zero.ro
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.2
tlpPduInputNominalVoltagePhaseToNeutralThe nominal value of the input line voltage as measured from phase to neutral. This value may not be supported on all models. If not supported, this value will always return zero.ro
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.3
tlpPduInputLowTransferVoltageThe minimum line voltage allowed before the unit disconnects the AC input connection. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned. When supported, the minimum and maximum values allowed are dictated by tlpPduInputLowTransferVoltageLowerBound and tlpPduInputLowTransferVoltageUpperBound respectively.ro
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.4
tlpPduInputLowTransferVoltageLowerBoundThe lower boundary value of tlpPduInputLowTransferVoltage as dictated by the hardware of the unit.ro
Unsigned32 UNITS "Volts"
.1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.5
tlpPduInputLowTransferVoltageUpperBoundThe upper boundary value of tlpPduInputLowTransferVoltage as dictated by the hardware of the unit.ro
Unsigned32 UNITS "Volts"
.1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.6
tlpPduInputHighTransferVoltageThe maximum line voltage allowed before the unit disconnects the AC input connection. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned. When supported, the minimum and maximum values allowed are dictated by tlpPduInputHighTransferVoltageLowerBound and tlpPduInputHighTransferVoltageUpperBound respectively.ro
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.7
tlpPduInputHighTransferVoltageLowerBoundThe lower boundary value of tlpPduInputHighTransferVoltage as dictated by the hardware of the unit.ro
Unsigned32 UNITS "Volts"
.1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.8
tlpPduInputHighTransferVoltageUpperBoundThe upper boundary value of tlpPduInputHighTransferVoltage as dictated by the hardware of the unit.ro
Unsigned32 UNITS "Volts"
.1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.9
tlpPduInputCurrentLimitThe capacity of each phase conductor in the pdu limited by the AC input cord or any other potential limiting factors unique to a given unit.ro
Unsigned32 UNITS "Amp DC"
.1.3.6.1.4.1.850.1.1.3.2.3.1.1.1.10
tlpPduInputPhaseTableThe input phase details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpPduIdentNumInputs and tlpPduIdentNumPhases per each device.
SEQUENCE OF TlpPduInputPhaseEntry
.1.3.6.1.4.1.850.1.1.3.2.3.1.2
tlpPduInputPhaseEntryAn entry containing information applicable to a particular input phase managed by this agent.
TlpPduInputPhaseEntry
.1.3.6.1.4.1.850.1.1.3.2.3.1.2.1
tlpPduInputPhaseIndexThe table row index for the pdu phase.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.1
tlpPduInputPhasePhaseTypeDenotes whether measurements are phase to neutral(0) or phase to phase(1).ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.2
tlpPduInputPhaseFrequencyThe present input frequency for a given phase.ro
Unsigned32 UNITS "0.1 Hertz"
.1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.3
tlpPduInputPhaseVoltageThe magnitude of the present input voltage for a given phase.ro
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.4
tlpPduInputPhaseVoltageMinThe minimum input voltage value since the last reset of this value for a given phase. If any value is written to either tlpPduInputVoltageMin or tlpPduInputVoltageMax, both will be reset to their appropriate minimum and maximum values.rw
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.5
tlpPduInputPhaseVoltageMaxThe maximum input voltage value since the last reset of this value for a given phase. If any value is written to either tlpPduInputVoltageMin or tlpPduInputVoltageMax, both will be reset to their appropriate minimum and maximum values.rw
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.6
tlpPduInputPhaseCurrentThe magnitude of the present input current for a given phase.ro
Unsigned32 UNITS "0.01 Amp DC"
.1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.7
tlpPduOutput
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.2.3.2
tlpPduOutputTableThe output details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpPduIdentNumOutputs per each device.
SEQUENCE OF TlpPduOutputEntry
.1.3.6.1.4.1.850.1.1.3.2.3.2.1
tlpPduOutputEntryAn entry containing output information applicable to a particular phase managed by this agent.
TlpPduOutputEntry
.1.3.6.1.4.1.850.1.1.3.2.3.2.1.1
tlpPduOutputIndexThe table row index for the pdu phase.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.1
tlpPduOutputPhaseIndicates the phase associated with the output line.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.2
tlpPduOutputPhaseTypeDenotes whether measurements are phase to neutral(0) or phase to phase(1).ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.3
tlpPduOutputVoltageThe magnitude of the present output voltage for a given output line.ro
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.4
tlpPduOutputCurrentThe output current, in hundreths of amps, for a given phase.ro
Unsigned32 UNITS "0.01 Amp DC"
.1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.5
tlpPduOutputCurrentMinThe minimum current observed for a given phase since last reset.ro
Unsigned32 UNITS "0.01 Amp DC"
.1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.6
tlpPduOutputCurrentMaxThe maximum current observed for a given phase since last reset.ro
Unsigned32 UNITS "0.01 Amp DC"
.1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.7
tlpPduOutputActivePowerThe output power for a given phase.ro
Unsigned32 UNITS "Watts"
.1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.8
tlpPduOutputPowerFactorThe output power factor, in hundreths of a percent, for a given phase.ro
Unsigned32 UNITS "0.01 percent"
.1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.9
tlpPduOutputSourceThe present source of output power. The enumeration none(0) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.3.2.1.1.10
tlpPduOutlet
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.2.3.3
tlpPduOutletTableThe receptacle status details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpPduIdentNumOutlets per each device.
SEQUENCE OF TlpPduOutletEntry
.1.3.6.1.4.1.850.1.1.3.2.3.3.1
tlpPduOutletEntryAn entry containing information applicable to a particular outlet managed by this agent.
TlpPduOutletEntry
.1.3.6.1.4.1.850.1.1.3.2.3.3.1.1
tlpPduOutletIndexThe table row index for the pdu outlet.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.1
tlpPduOutletNameA user-definable string identifying the name of the outlet.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.2
tlpPduOutletDescriptionA user-definable string identifying the device(s) connected to the given outlet.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.3
tlpPduOutletStateThe current state of the outlet.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.4
tlpPduOutletControllableDenotes whether this outlet is controllable.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.5
tlpPduOutletCommandReading this value will always return 0. Setting this value to turnOff(1) will turn off the outlet. Setting this value to turnOn(2) will turn on the outlet. Setting this value to cycle(3) will turn the outlet off, then turn it back on.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.6
tlpPduOutletVoltageThe magnitude of the present output voltage for a given outlet. If the voltage measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle voltage measurements is denoted by tlpPduSupportsOutletVoltage.ro
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.7
tlpPduOutletCurrentThe present output current, in hundreths of amps, of a given outlet. If the current measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle current measurements is denoted by tlpPduSupportsCurrentPower.ro
Unsigned32 UNITS "0.01 RMS Amp"
.1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.8
tlpPduOutletPowerThe output power of a given outlet. If the power measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle power measurements is denoted by tlpPduSupportsCurrentPower.ro
Unsigned32 UNITS "Watts"
.1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.9
tlpPduOutletRampActionThe ramp action to take on a given outlet when powering on the device. If this receptacle is not controllable, as denoted by tlpPduOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.10
tlpPduOutletRampDelayThe number of seconds to delay before powering on the given outlet. If this receptacle is not controllable, as denoted by tlpPduOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.rw
Integer32 UNITS "seconds"
.1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.11
tlpPduOutletShedActionThe shed action to take on a given outlet when powering off the device. If this receptacle is not controllable, as denoted by tlpPduOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.12
tlpPduOutletShedDelayThe number of seconds to delay before powering off the given outlet. If this receptacle is not controllable, as denoted by tlpPduOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.rw
Integer32 UNITS "seconds"
.1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.13
tlpPduOutletGroupThe tlpPduOutletGroupIndex group index of the respective group to which the given outlet is assigned, or zero (0) if the given outlet is not grouped.rw
Integer32
.1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.14
tlpPduOutletBankIndicates on which bank the given outlet is located.ro
Integer32
.1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.15
tlpPduOutletCircuitIndicates on which circuit the given outlet is wired.ro
Integer32
.1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.16
tlpPduOutletPhaseIndicates on which phase or phases the given outlet is associated. For single phase devices, this object will always return phase1(1). For 3-phase devices with outlets wired to a single phase, this object will return phase1(1), phase2(2) or phase3(3). For 3-phase devices with outlets wired to two phases, this object will return phase1-2(4) for phases 1 and 2, phase2-3(5) for phases 2 and 3, and phase3-1(6) for phases 3 and 1. Devices that do not report phase connections will return unknown(0).ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.3.3.1.1.17
tlpPduOutletGroupTableThe receptacle grouping details of each pdu in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpPduIdentNumOutletGroups per each device.
SEQUENCE OF TlpPduOutletGroupEntry
.1.3.6.1.4.1.850.1.1.3.2.3.3.2
tlpPduOutletGroupEntryAn entry containing information applicable to a particular outlet group managed by this agent.
TlpPduOutletGroupEntry
.1.3.6.1.4.1.850.1.1.3.2.3.3.2.1
tlpPduOutletGroupIndexThe table row index for the pdu outlet group.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.1
tlpPduOutletGroupRowStatusRow status for the tlpPduOutletGroupTablerw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.2
tlpPduOutletGroupNameThe name of this outlet group.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.3
tlpPduOutletGroupDescriptionA description for this outlet group.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.4
tlpPduOutletGroupStateThe current state of the outlet group. This value will report off(1) if all outlets in the group are off, on(2) if all outlets in the group are on, mixed(3) if some outlets in the group are off and others are on, or unknown(0) if the state of the outlets cannot be determined.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.5
tlpPduOutletGroupCommandReading this value will always return 0. Setting this value to turnOff(1) will turn off every outlet associated with the group. Setting this value to turnOn(2) will turn on every outlet associated with the group. Setting this value to cycle(3) will turn off every outlet associated with the group, then turn each outlet back on.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.3.3.2.1.6
tlpPduCircuit
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.2.3.4
tlpPduCircuitTableA list of pdu circuit table entries. The number of entries is given by the value of tlpPduIdentNumCircuits.
SEQUENCE OF TlpPduCircuitEntry
.1.3.6.1.4.1.850.1.1.3.2.3.4.1
tlpPduCircuitEntryAn entry containing information applicable to a particular circuit managed by this agent.
TlpPduCircuitEntry
.1.3.6.1.4.1.850.1.1.3.2.3.4.1.1
tlpPduCircuitIndexThe table row index for the pdu circuit.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.1
tlpPduCircuitPhaseIndicates on which phase or phases the given circuit is wired. For single phase devices, this object will always return phase1(1). For 3-phase devices with outlets wired to a single phase, this object will return phase1(1), phase2(2) or phase3(3). For 3-phase devices with outlets wired to two phases, this object will return phase1-2(4) for phases 1 and 2, phase2-3(5) for phases 2 and 3, and phase3-1(6) for phases 3 and 1. Devices that do not report phase connections will return unknown(0).ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.2
tlpPduCircuitInputVoltageThe input voltage for a circuit.ro
Integer32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.3
tlpPduCircuitTotalCurrentThe total current for all receptacles in a given circuit.ro
Integer32 UNITS "0.01 Amp DC"
.1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.4
tlpPduCircuitCurrentLimitThe current capacity of a circuit in the system limited by the circuit breaker or wiring used in a given unit.ro
Integer32 UNITS "0.01 Amp DC"
.1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.5
tlpPduCircuitCurrentMinThe minimum total current for all receptacles in a given circuit since last reset.ro
Integer32 UNITS "0.01 Amp DC"
.1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.6
tlpPduCircuitCurrentMaxThe maximum total current for all receptacles in a given circuit since last reset.ro
Integer32 UNITS "0.01 Amp DC"
.1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.7
tlpPduCircuitTotalPowerThe total power for all receptacles in a given circuit.ro
Integer32 UNITS "Watts"
.1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.8
tlpPduCircuitPowerFactorThe power factor for all receptacles in a given circuit.ro
INTEGER
.1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.9
tlpPduCircuitUtilizationThe percentage of utilization of a given circuit. This is typically a calculation of tlpPduCircuitTotalCurrent / tlpPduCircuitCurrentLimit.ro
Unsigned32 UNITS "0.01 %"
.1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.10
tlpPduBreaker
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.2.3.5
tlpPduBreakerTableA list of pdu bank breaker table entries. The number of entries is given by the value of tlpPduIdentNumBreakers.
SEQUENCE OF TlpPduBreakerEntry
.1.3.6.1.4.1.850.1.1.3.2.3.5.1
tlpPduBreakerEntryAn entry containing information applicable to a particular bank breaker managed by this agent.
TlpPduBreakerEntry
.1.3.6.1.4.1.850.1.1.3.2.3.5.1.1
tlpPduBreakerIndexThe table row index for the pdu bank breaker.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.2.3.5.1.1.1
tlpPduBreakerStatusIndicates whether the bank breaker is open(0), closed(1) or not installed(2).ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.3.5.1.1.2
tlpPduHeatsink
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.2.3.6
tlpPduHeatsinkTableA list of pdu heatsink thermistor table entries. The number of entries is given by the value of tlpPduIdentNumHeatsinks.
SEQUENCE OF TlpPduHeatsinkEntry
.1.3.6.1.4.1.850.1.1.3.2.3.6.1
tlpPduHeatsinkEntryAn entry containing information applicable to a particular heatsink thermistor managed by this agent.
TlpPduHeatsinkEntry
.1.3.6.1.4.1.850.1.1.3.2.3.6.1.1
tlpPduHeatsinkIndexThe table row index for the pdu heatsink thermistor.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.2.3.6.1.1.1
tlpPduHeatsinkStatusIndicates whether the heatsink thermistor is available. The entry will return notAvailable(0) if a thermistor is either non-existent or disconnected, or available(1) when connected.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.2.3.6.1.1.2
tlpPduHeatsinkTemperatureCThe temperature at the heatsink termistor in tenths degrees Centigrade. Heatsink temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.ro
Integer32 UNITS "0.1 degrees Centigrade"
.1.3.6.1.4.1.850.1.1.3.2.3.6.1.1.3
tlpPduHeatsinkTemperatureFThe temperature at the heatsink termistor in tenths degrees Farenheit. Heatsink temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.ro
Integer32 UNITS "0.1 degrees Farenheit"
.1.3.6.1.4.1.850.1.1.3.2.3.6.1.1.4
tlpPduControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.2.4
tlpPduControlTableThe actionable controls for each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus.
SEQUENCE OF TlpPduControlEntry
.1.3.6.1.4.1.850.1.1.3.2.4.1
tlpPduControlEntryAn entry containing controls for a particular pdu.
TlpPduControlEntry
.1.3.6.1.4.1.850.1.1.3.2.4.1.1
tlpPduControlRampSet to TRUE to initiate the pre-designated ramp sequence on the pdu.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.2.4.1.1.1
tlpPduControlShedSet to TRUE to initiate the pre-designated shed sequence on the pdu.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.2.4.1.1.2
tlpPduControlPduOnSet to TRUE to turn the pdu on.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.2.4.1.1.3
tlpPduControlPduOffSet to TRUE to turn the pdu off.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.2.4.1.1.4
tlpPduControlPduRebootSet to TRUE to reboot the pdu.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.2.4.1.1.5
tlpPduConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.2.5
tlpPduConfigTableThe configuration options of each pdu in device table. This is a sparse dependent table, and will contain some subset of devices that are pdus. Not all options are available on all pdus.
SEQUENCE OF TlpPduConfigEntry
.1.3.6.1.4.1.850.1.1.3.2.5.1
tlpPduConfigEntryAn entry containing configuration options for a particular pdu.
TlpPduConfigEntry
.1.3.6.1.4.1.850.1.1.3.2.5.1.1
tlpPduConfigInputVoltageThe nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned.rw
Unsigned32
.1.3.6.1.4.1.850.1.1.3.2.5.1.1.1
tlpEnvirosense
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.3
tlpEnvIdent
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.3.1
tlpEnvIdentNumEnvirosenseThe number of envirosense devices that this agent is currently managing.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.3.1.1
tlpEnvIdentTableThe identity details of each envirosense in device table. The number of entries is given by the value of tlpDevicesNumDevices.
SEQUENCE OF TlpEnvIdentEntry
.1.3.6.1.4.1.850.1.1.3.3.1.2
tlpEnvIdentEntryAn entry containing details for a particular envirosense.
TlpEnvIdentEntry
.1.3.6.1.4.1.850.1.1.3.3.1.2.1
tlpEnvIdentTempSupportedIndicates whether or not temperature is supported.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.3.1.2.1.1
tlpEnvIdentHumiditySupportedIndicates whether or not temperature is supported.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.3.1.2.1.2
tlpEnvNumInputContactsThe number of input contacts supported by the envirosense.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.3.1.2.1.3
tlpEnvNumOutputContactsThe number of output contacts supported by the envirosense.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.3.1.2.1.4
tlpEnvDetail
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.3.3
tlpEnvTemperatureTableThe temperature details of each envirosense in device table. The number of entries is given by the value of tlpDevicesNumDevices.
SEQUENCE OF TlpEnvTemperatureEntry
.1.3.6.1.4.1.850.1.1.3.3.3.1
tlpEnvTemperatureEntryAn entry containing temperature details for a particular envirosense.
TlpEnvTemperatureEntry
.1.3.6.1.4.1.850.1.1.3.3.3.1.1
tlpEnvTemperatureCThe ambient temperature.ro
Integer32 UNITS "degrees Centigrade"
.1.3.6.1.4.1.850.1.1.3.3.3.1.1.1
tlpEnvTemperatureFThe ambient temperature.ro
Integer32 UNITS "0.1 degrees Farenheit"
.1.3.6.1.4.1.850.1.1.3.3.3.1.1.2
tlpEnvTemperatureInAlarmIndicates whether or not temperature is in alarm.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.3.3.1.1.3
tlpEnvHumidityTableThe humidity details of each envirosense in device table. The number of entries is given by the value of tlpDevicesNumDevices.
SEQUENCE OF TlpEnvHumidityEntry
.1.3.6.1.4.1.850.1.1.3.3.3.2
tlpEnvHumidityEntryAn entry containing humidity details for a particular envirosense.
TlpEnvHumidityEntry
.1.3.6.1.4.1.850.1.1.3.3.3.2.1
tlpEnvHumidityHumidityThe ambient humidity.ro
INTEGER
.1.3.6.1.4.1.850.1.1.3.3.3.2.1.1
tlpEnvHumidityInAlarmIndicates whether or not humidity is in alarm.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.3.3.2.1.2
tlpEnvInputContactTableThe input contact details of each envirosense in device table. The number of entries is given by the value of tlpDevicesNumDevices.
SEQUENCE OF TlpEnvInputContactEntry
.1.3.6.1.4.1.850.1.1.3.3.3.3
tlpEnvInputContactEntryAn entry containing input contact details for a particular envirosense.
TlpEnvInputContactEntry
.1.3.6.1.4.1.850.1.1.3.3.3.3.1
tlpEnvInputContactIndexThe table row index for the envirosense input contact details.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.3.3.3.1.1
tlpEnvInputContactNameThe name or description of the contact.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.3.3.3.1.2
tlpEnvInputContactNormalStateThe normal operating position of the contact.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.3.3.3.1.3
tlpEnvInputContactCurrentStateThe current state of the contact.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.3.3.3.1.4
tlpEnvInputContactInAlarmIndicates whether or not the contact is in alarm.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.3.3.3.1.5
tlpEnvOutputContactTableThe output contact details of each envirosense in device table. The number of entries is given by the value of tlpDevicesNumDevices.
SEQUENCE OF TlpEnvOutputContactEntry
.1.3.6.1.4.1.850.1.1.3.3.3.4
tlpEnvOutputContactEntryAn entry containing output contact details for a particular envirosense.
TlpEnvOutputContactEntry
.1.3.6.1.4.1.850.1.1.3.3.3.4.1
tlpEnvOutputContactIndexThe table row index for the envirosense output contact details.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.3.3.4.1.1
tlpEnvOutputContactNameThe name or description of the contact.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.3.3.4.1.2
tlpEnvOutputContactNormalStateThe normal operating position of the contact.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.3.3.4.1.3
tlpEnvOutputContactCurrentStateThe current state of the contact.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.3.3.4.1.4
tlpEnvOutputContactInAlarmIndicates whether or not the contact is in alarm.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.3.3.4.1.5
tlpEnvConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.3.5
tlpEnvConfigTableThe configuration options of each envirosense in device table. This is a sparse dependent table, and will contain some subset of devices that are envirosenses. Not all options are available on all envirosenses.
SEQUENCE OF TlpEnvConfigEntry
.1.3.6.1.4.1.850.1.1.3.3.5.1
tlpEnvConfigEntryAn entry containing configuration options for a particular envirosenses.
TlpEnvConfigEntry
.1.3.6.1.4.1.850.1.1.3.3.5.1.1
tlpEnvTemperatureLowLimitThe lower alarm limit for ambient temperature.rw
Integer32 UNITS "degrees Farenheit"
.1.3.6.1.4.1.850.1.1.3.3.5.1.1.1
tlpEnvTemperatureHighLimitThe upper alarm limit for ambient temperature.rw
Integer32 UNITS "degrees Farenheit"
.1.3.6.1.4.1.850.1.1.3.3.5.1.1.2
tlpEnvHumidityLowLimitThe lower alarm limit for ambient humidity.rw
INTEGER
.1.3.6.1.4.1.850.1.1.3.3.5.1.1.3
tlpEnvHumidityHighLimitThe upper alarm limit for ambient humidity.rw
INTEGER
.1.3.6.1.4.1.850.1.1.3.3.5.1.1.4
tlpAts
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.4
tlpAtsIdent
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.4.1
tlpAtsIdentNumAtsThe number of ats devices that this agent is currently managing.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.1.1
tlpAtsIdentTableThe identity details of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss.
SEQUENCE OF TlpAtsIdentEntry
.1.3.6.1.4.1.850.1.1.3.4.1.2
tlpAtsIdentEntryAn entry containing details for a particular ats.
TlpAtsIdentEntry
.1.3.6.1.4.1.850.1.1.3.4.1.2.1
tlpAtsIdentNumInputsThe number of inputs supported by the ats.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.1.2.1.1
tlpAtsIdentNumOutputsThe number of outputs supported by the ats.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.1.2.1.2
tlpAtsIdentNumPhasesThe number of phases per input supported by the ats.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.1.2.1.3
tlpAtsIdentNumOutletsThe number of receptacles supported by the ats.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.1.2.1.4
tlpAtsIdentNumOutletGroupsThe number of receptacle groups supported by the ats.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.1.2.1.5
tlpAtsIdentNumCircuitsThe number of circuits supported by the ats.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.1.2.1.6
tlpAtsIdentNumBreakersThe number of bank breakers supported by the ats.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.1.2.1.7
tlpAtsIdentNumHeatsinksThe number of heatsink thermistors supported by the ats.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.1.2.1.8
tlpAtsSupportsTableThe supported details of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss.
SEQUENCE OF TlpAtsSupportsEntry
.1.3.6.1.4.1.850.1.1.3.4.1.3
tlpAtsSupportsEntryAn entry containing supported details for a particular ats.
TlpAtsSupportsEntry
.1.3.6.1.4.1.850.1.1.3.4.1.3.1
tlpAtsSupportsEnergywiseIndicates whether the ats supports Cisco EnergyWise.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.1.3.1.1
tlpAtsSupportsRampShedIndicates whether the ats supports ramping and shedding.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.1.3.1.2
tlpAtsSupportsOutletGroupIndicates whether the ats supports outlet groups.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.1.3.1.3
tlpAtsSupportsOutletCurrentPowerIndicates whether the ats reports individual receptacle current and power measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpAtsOutletCurrent and tlpAtsOutletPower.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.1.3.1.4
tlpAtsSupportsOutletVoltageIndicates whether the ats reports individual receptacle voltage measurements. Devices that do not support individual receptacle measurements will always return ERROR_NO_SUCH_NAME for tlpAtsOutletVoltage.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.1.3.1.5
tlpAtsDisplayTableThe display details of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss.
SEQUENCE OF TlpAtsDisplayEntry
.1.3.6.1.4.1.850.1.1.3.4.1.4
tlpAtsDisplayEntryAn entry containing display details for a particular ats.
TlpAtsDisplayEntry
.1.3.6.1.4.1.850.1.1.3.4.1.4.1
tlpAtsDisplaySchemeIndicates the display scheme of the LED display. The value schemeReverse(0) indicates the tricolor LED indicator uses an alternate pattern. The value schemeNormal(1) indicates the LED indicator uses the standard pattern. This value may not be supported on all models. If not supported, the value will always return schemeNormal(1).rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.1.4.1.1
tlpAtsDisplayOrientationIndicates the physical orientation of the LED display. The value displayNormal(0) indicates the display is right-side-up (normal). The value displayReverse(1) indicates the display is upside-down. This value may not be supported on all models. If not supported, the value will always return displayNormal(0).rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.1.4.1.2
tlpAtsDisplayAutoScrollIndicates whether the LED display automatically scrolls through displaying status values.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.1.4.1.3
tlpAtsDisplayIntensityIndicates the intensity, as a percentage, of the LED display. The value intensity100(4) indicates the display is at 100% intensity. The other values indicate the display is at a lesser intensity based upon the respective percentage denoted.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.1.4.1.4
tlpAtsDisplayUnitsIndicates the units of measurement displayed on the LED display. The value normal(0) indicates that a temperature value, for example, is displayed in degrees Farenheit. The value metric(1) indicates a temperature value is displayed in degrees Celsius.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.1.4.1.5
tlpAtsDevice
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.4.2
tlpAtsDeviceTableThe device details of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss.
SEQUENCE OF TlpAtsDeviceEntry
.1.3.6.1.4.1.850.1.1.3.4.2.1
tlpAtsDeviceEntryAn entry containing device details for a particular ats.
TlpAtsDeviceEntry
.1.3.6.1.4.1.850.1.1.3.4.2.1.1
tlpAtsDeviceMainLoadStateThe current state of the main output of the device.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.2.1.1.1
tlpAtsDeviceMainLoadControllableIndicates whether or not the main output is controllable, and whether the ups can be turned off and on.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.2.1.1.2
tlpAtsDeviceMainLoadCommandReading this value will always return 0. Setting this value to turnOff(1) will turn off the main output of the ups. Setting this value to turnOn(2) will turn on the main output of the ups. Setting this value to cycle(3) will turn off the main output, then turn it back on.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.2.1.1.3
tlpAtsDevicePowerOnDelayThe configurable delay value, which sets the amount of additional time a given device will wait before it connects to a valid AC source. By default the delay value is set to 0. For devices with multiple AC input sources, this delay only applies to the primary input source.rw
Integer32
.1.3.6.1.4.1.850.1.1.3.4.2.1.1.4
tlpAtsDeviceTotalInputPowerRatingThe total input power rating of all phases on the device. This value may not be supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.ro
Integer32 UNITS "Watts"
.1.3.6.1.4.1.850.1.1.3.4.2.1.1.5
tlpAtsDeviceTemperatureCThe ambient temperature at or near the ats casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.ro
Integer32 UNITS "degrees Centigrade"
.1.3.6.1.4.1.850.1.1.3.4.2.1.1.6
tlpAtsDeviceTemperatureFThe ambient temperature at or near the ats casing. Temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.ro
Integer32 UNITS "degrees Farenheit"
.1.3.6.1.4.1.850.1.1.3.4.2.1.1.7
tlpAtsDevicePhaseImbalanceThe percentage of imbalance of the three phases. This value is in the range from 0% imbalance to 100% imbalance. The lower the value, the better balanced the phases are. If all load is on a single phase, the imbalance is defined as 100%.ro
INTEGER
.1.3.6.1.4.1.850.1.1.3.4.2.1.1.8
tlpAtsDeviceOutputPowerTotalThe AC output total power for all circuits.ro
Unsigned32 UNITS "Watts"
.1.3.6.1.4.1.850.1.1.3.4.2.1.1.9
tlpAtsDeviceAggregatePowerFactorThe aggregrate power factor of all phases.ro
Unsigned32 UNITS "0.1 Watts"
.1.3.6.1.4.1.850.1.1.3.4.2.1.1.10
tlpAtsDeviceOutputCurrentPrecisionOutput current is reported by tlpAtsOutputCurrent, tlpAtsOutputCurrentMin and tlpAtsOutputCurrentMax. These values are all reported in hundredths (0.01A), which accommodates all models; however, on any given device the actual precision may vary. This value describes the actual precision, which can be used as a divisor against the output current values to obtain the true output current measurement. For example, if tlpAtsOutputCurrent reports 530 and tlpAtsDeviceOutputCurrentPrecision is tenths(1), then the actual output current is 5.3.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.2.1.1.11
tlpAtsDeviceGeneralFaultIndicates whether or not the ats is in a system fault condition. When the ats is in such a fault condition, the condition can be cleared with tlpAtsControlResetGeneralFault.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.2.1.1.12
tlpAtsDetail
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.4.3
tlpAtsInput
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.4.3.1
tlpAtsInputTableThe input details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the number of atss managed by the agent as reported by tlpAtsIdentNumAts.
SEQUENCE OF TlpAtsInputEntry
.1.3.6.1.4.1.850.1.1.3.4.3.1.1
tlpAtsInputEntryAn entry containing information applicable to a particular primary input phase managed by this agent.
TlpAtsInputEntry
.1.3.6.1.4.1.850.1.1.3.4.3.1.1.1
tlpAtsInputNominalVoltageThe nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.1
tlpAtsInputNominalVoltagePhaseToPhaseThe nominal value of the input line voltage as measured from phase to phase. This value may not be supported on all models. If not supported, this value will always return zero.ro
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.2
tlpAtsInputNominalVoltagePhaseToNeutralThe nominal value of the input line voltage as measured from phase to neutral. This value may not be supported on all models. If not supported, this value will always return zero.ro
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.3
tlpAtsInputBadTransferVoltageThe minimum line voltage allowed before the unit disconnects the AC input connection.ro
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.4
tlpAtsInputBadTransferVoltageLowerBoundThe lower boundary value of tlpAtsInputBadTransferVoltage as dictated by the hardware of the unit.ro
Unsigned32 UNITS "Volts"
.1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.5
tlpAtsInputBadTransferVoltageUpperBoundThe upper boundary value of tlpAtsInputBadTransferVoltage as dictated by the hardware of the unit.ro
Unsigned32 UNITS "Volts"
.1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.6
tlpAtsInputHighTransferVoltageThe maximum line voltage allowed before the unit disconnects the AC input connection.ro
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.7
tlpAtsInputHighTransferVoltageLowerBoundThe lower boundary value of tlpAtsInputHighTransferVoltage as dictated by the hardware of the unit.ro
Unsigned32 UNITS "Volts"
.1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.8
tlpAtsInputHighTransferVoltageUpperBoundThe upper boundary value of tlpAtsInputHighTransferVoltage as dictated by the hardware of the unit.ro
Unsigned32 UNITS "Volts"
.1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.9
tlpAtsInputFairVoltageThresholdThe voltage level at which the device will transition between sources.ro
Unsigned32 UNITS "Volts"
.1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.10
tlpAtsInputBadVoltageThresholdThe minimum line voltage allowed before the device disconnects the AC input connection.ro
Unsigned32 UNITS "Volts"
.1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.11
tlpAtsInputSourceAvailabilityThe determination as to which of two AC input lines are available. The agent will return either inputSourceA(1) or inputSourceB(2) if only one line is available, or inputSourceAB(3) if both lines are available. The agent will never return none(0) since the device will be powered off if neither line is available.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.12
tlpAtsInputSourceInUseThe determination as to which one of two AC input lines is in use. Not all devices support the reporting of which source is currently in use. If not supported, this value will always return ERROR_NO_SUCH_NAME.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.13
tlpAtsInputSourceTransitionCountThe number of times the device transitions between primary and secondary sources. Most devices are limied to 65533 transitions, after which the value will not increment. If not supported, this value will always return ERROR_NO_SUCH_NAME.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.14
tlpAtsInputCurrentLimitThe capacity of each phase conductor in the ats limited by the AC input cord or any other potential limiting factors unique to a given unit. If not supported, this value will always return ERROR_NO_SUCH_NAME.ro
Unsigned32 UNITS "Amp DC"
.1.3.6.1.4.1.850.1.1.3.4.3.1.1.1.15
tlpAtsInputPhaseTableThe input phase details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpAtsIdentNumInputs and tlpAtsIdentNumPhases per each device.
SEQUENCE OF TlpAtsInputPhaseEntry
.1.3.6.1.4.1.850.1.1.3.4.3.1.2
tlpAtsInputPhaseEntryAn entry containing information applicable to a particular primary input phase managed by this agent.
TlpAtsInputPhaseEntry
.1.3.6.1.4.1.850.1.1.3.4.3.1.2.1
tlpAtsInputLineIndexThe table row index for the input line on the ats.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.1
tlpAtsInputPhaseIndexThe table row index for the input phase for the input line.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.2
tlpAtsInputPhaseTypeDenotes whether measurements are phase to neutral(0) or phase to phase(1).ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.3
tlpAtsInputPhaseFrequencyThe present input frequency for a given phase.ro
Unsigned32 UNITS "0.1 Hertz"
.1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.4
tlpAtsInputPhaseVoltageThe magnitude of the present input voltage for a given phase.ro
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.5
tlpAtsInputPhaseVoltageMinThe minimum input voltage value since the last reset of this value for a given phase. If any value is written to either tlpAtsInputVoltageMin or tlpAtsInputVoltageMax, both will be reset to their appropriate minimum and maximum values.rw
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.6
tlpAtsInputPhaseVoltageMaxThe maximum input voltage value since the last reset of this value for a given phase. If any value is written to either tlpAtsInputVoltageMin or tlpAtsInputVoltageMax, both will be reset to their appropriate minimum and maximum values.rw
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.7
tlpAtsInputPhaseCurrentThe magnitude of the present input current for a given phase.ro
Unsigned32 UNITS "0.01 Amp DC"
.1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.8
tlpAtsOutput
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.4.3.2
tlpAtsOutputTableThe output details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpAtsIdentNumOutputs per each device.
SEQUENCE OF TlpAtsOutputEntry
.1.3.6.1.4.1.850.1.1.3.4.3.2.1
tlpAtsOutputEntryAn entry containing output information applicable to a particular phase managed by this agent.
TlpAtsOutputEntry
.1.3.6.1.4.1.850.1.1.3.4.3.2.1.1
tlpAtsOutputIndexThe table row index for the ats phase.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.1
tlpAtsOutputPhaseIndicates the phase associated with the output line.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.2
tlpAtsOutputPhaseTypeDenotes whether measurements are phase to neutral(0) or phase to phase(1).ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.3
tlpAtsOutputVoltageThe magnitude of the present output voltage for a given output line.ro
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.4
tlpAtsOutputCurrentThe output current, in hundreths of amps, for a given phase.ro
Unsigned32 UNITS "0.01 Amp DC"
.1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.5
tlpAtsOutputCurrentMinThe minimum current observed for a given phase since last reset.ro
Unsigned32 UNITS "0.01 Amp DC"
.1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.6
tlpAtsOutputCurrentMaxThe maximum current observed for a given phase since last reset.ro
Unsigned32 UNITS "0.01 Amp DC"
.1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.7
tlpAtsOutputActivePowerThe output power for a given phase.ro
Unsigned32 UNITS "Watts"
.1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.8
tlpAtsOutputPowerFactorThe output power factor, in hundreths of a percent, for a given phase.ro
Unsigned32 UNITS "0.01 percent"
.1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.9
tlpAtsOutputSourceThe present source of output power. The enumeration none(0) indicates that there is no source of output power (and therefore no output power), for example, the system has opened the output breaker.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.10
tlpAtsOutlet
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.4.3.3
tlpAtsOutletTableThe receptacle status details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpAtsIdentNumOutlets per each device.
SEQUENCE OF TlpAtsOutletEntry
.1.3.6.1.4.1.850.1.1.3.4.3.3.1
tlpAtsOutletEntryAn entry containing information applicable to a particular outlet managed by this agent.
TlpAtsOutletEntry
.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1
tlpAtsOutletIndexThe table row index for the ats outlet.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.1
tlpAtsOutletNameA user-definable string identifying the name of the outlet.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.2
tlpAtsOutletDescriptionA user-definable string identifying the device(s) connected to the given outlet.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.3
tlpAtsOutletStateThe current state of the outlet.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.4
tlpAtsOutletControllableDenotes whether this outlet is controllable.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.5
tlpAtsOutletCommandReading this value will always return 0. Setting this value to turnOff(1) will turn off the outlet. Setting this value to turnOn(2) will turn on the outlet. Setting this value to cycle(3) will turn the outlet off, then turn it back on.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.6
tlpAtsOutletVoltageThe magnitude of the present output voltage for a given outlet. If the voltage measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle voltage measurements is denoted by tlpAtsSupportsOutletVoltage.ro
Unsigned32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.7
tlpAtsOutletCurrentThe present output current, in hundreths of amps, of a given outlet. If the current measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle current measurements is denoted by tlpAtsSupportsCurrentPower.ro
Unsigned32 UNITS "0.01 RMS Amp"
.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.8
tlpAtsOutletPowerThe output power of a given outlet. If the power measurement is not supported for an individual receptacle regardless whether device-wide or just for this receptacle, then this value will always return ERROR_NO_SUCH_NAME. Device-wide support for receptacle power measurements is denoted by tlpAtsSupportsCurrentPower.ro
Unsigned32 UNITS "Watts"
.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.9
tlpAtsOutletRampActionThe ramp action to take on a given outlet when powering on the device. If this receptacle is not controllable, as denoted by tlpAtsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.10
tlpAtsOutletRampDelayThe number of seconds to delay before powering on the given outlet. If this receptacle is not controllable, as denoted by tlpAtsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.rw
Integer32 UNITS "seconds"
.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.11
tlpAtsOutletShedActionThe shed action to take on a given outlet when powering off the device. If this receptacle is not controllable, as denoted by tlpAtsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.12
tlpAtsOutletShedDelayThe number of seconds to delay before powering off the given outlet. If this receptacle is not controllable, as denoted by tlpAtsOutletControllable, then this value will always return ERROR_NO_SUCH_NAME.rw
Integer32 UNITS "seconds"
.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.13
tlpAtsOutletGroupThe tlpAtsOutletGroupIndex group index of the respective group to which the given outlet is assigned, or zero (0) if the given outlet is not grouped.rw
Integer32
.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.14
tlpAtsOutletBankIndicates on which bank the given outlet is located.ro
Integer32
.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.15
tlpAtsOutletCircuitIndicates on which circuit the given outlet is wired.ro
Integer32
.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.16
tlpAtsOutletPhaseIndicates on which phase or phases the given outlet is associated. For single phase devices, this object will always return phase1(1). For 3-phase devices with outlets wired to a single phase, this object will return phase1(1), phase2(2) or phase3(3). For 3-phase devices with outlets wired to two phases, this object will return phase1-2(4) for phases 1 and 2, phase2-3(5) for phases 2 and 3, and phase3-1(6) for phases 3 and 1. Devices that do not report phase connections will return unknown(0).ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.3.3.1.1.17
tlpAtsOutletGroupTableThe receptacle grouping details of each ats in device table. This is a sparse dependent table, and will contain the number of entries based upon the value of tlpAtsIdentNumOutletGroups per each device.
SEQUENCE OF TlpAtsOutletGroupEntry
.1.3.6.1.4.1.850.1.1.3.4.3.3.2
tlpAtsOutletGroupEntryAn entry containing information applicable to a particular outlet group managed by this agent.
TlpAtsOutletGroupEntry
.1.3.6.1.4.1.850.1.1.3.4.3.3.2.1
tlpAtsOutletGroupIndexThe table row index for the ats outlet group.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.1
tlpAtsOutletGroupRowStatusRow status for the tlpAtsOutletGroupTablerw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.2
tlpAtsOutletGroupNameThe name of this outlet group.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.3
tlpAtsOutletGroupDescriptionA description for this outlet group.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.4
tlpAtsOutletGroupStateThe current state of the outlet group. This value will report off(1) if all outlets in the group are off, on(2) if all outlets in the group are on, mixed(3) if some outlets in the group are off and others are on, or unknown(0) if the state of the outlets cannot be determined.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.5
tlpAtsOutletGroupCommandReading this value will always return 0. Setting this value to turnOff(1) will turn off every outlet associated with the group. Setting this value to turnOn(2) will turn on every outlet associated with the group. Setting this value to cycle(3) will turn off every outlet associated with the group, then turn each outlet back on.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.3.3.2.1.6
tlpAtsCircuit
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.4.3.4
tlpAtsCircuitTableA list of ats circuit table entries. The number of entries is given by the value of tlpAtsIdentNumCircuits.
SEQUENCE OF TlpAtsCircuitEntry
.1.3.6.1.4.1.850.1.1.3.4.3.4.1
tlpAtsCircuitEntryAn entry containing information applicable to a particular circuit managed by this agent.
TlpAtsCircuitEntry
.1.3.6.1.4.1.850.1.1.3.4.3.4.1.1
tlpAtsCircuitIndexThe table row index for the ats circuit.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.1
tlpAtsCircuitPhaseIndicates on which phase or phases the given circuit is wired. For single phase devices, this object will always return phase1(1). For 3-phase devices with outlets wired to a single phase, this object will return phase1(1), phase2(2) or phase3(3). For 3-phase devices with outlets wired to two phases, this object will return phase1-2(4) for phases 1 and 2, phase2-3(5) for phases 2 and 3, and phase3-1(6) for phases 3 and 1. Devices that do not report phase connections will return unknown(0).ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.2
tlpAtsCircuitInputVoltageThe input voltage for a circuit.ro
Integer32 UNITS "0.1 Volt DC"
.1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.3
tlpAtsCircuitTotalCurrentThe total current for all receptacles in a given circuit.ro
Integer32 UNITS "0.01 Amp DC"
.1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.4
tlpAtsCircuitCurrentLimitThe current capacity of a circuit in the system limited by the circuit breaker or wiring used in a given unit.ro
Integer32 UNITS "0.01 Amp DC"
.1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.5
tlpAtsCircuitCurrentMinThe minimum total current for all receptacles in a given circuit since last reset.ro
Integer32 UNITS "0.01 Amp DC"
.1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.6
tlpAtsCircuitCurrentMaxThe maximum total current for all receptacles in a given circuit since last reset.ro
Integer32 UNITS "0.01 Amp DC"
.1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.7
tlpAtsCircuitTotalPowerThe total power for all receptacles in a given circuit.ro
Integer32 UNITS "Watts"
.1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.8
tlpAtsCircuitPowerFactorThe power factor for all receptacles in a given circuit.ro
INTEGER
.1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.9
tlpAtsCircuitUtilizationThe percentage of utilization of a given circuit. This is typically a calculation of tlpAtsCircuitTotalCurrent / tlpAtsCircuitCurrentLimit.ro
Unsigned32 UNITS "0.01 %"
.1.3.6.1.4.1.850.1.1.3.4.3.4.1.1.10
tlpAtsBreaker
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.4.3.5
tlpAtsBreakerTableA list of ats bank breaker table entries. The number of entries is given by the value of tlpAtsIdentNumBreakers.
SEQUENCE OF TlpAtsBreakerEntry
.1.3.6.1.4.1.850.1.1.3.4.3.5.1
tlpAtsBreakerEntryAn entry containing information applicable to a particular bank breaker managed by this agent.
TlpAtsBreakerEntry
.1.3.6.1.4.1.850.1.1.3.4.3.5.1.1
tlpAtsBreakerIndexThe table row index for the ats bank breaker.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.3.5.1.1.1
tlpAtsBreakerStatusIndicates whether the bank breaker is open(0), closed(1) or not installed(2).ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.3.5.1.1.2
tlpAtsHeatsink
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.4.3.6
tlpAtsHeatsinkTableA list of ats heatsink thermistor table entries. The number of entries is given by the value of tlpAtsIdentNumHeatsinks.
SEQUENCE OF TlpAtsHeatsinkEntry
.1.3.6.1.4.1.850.1.1.3.4.3.6.1
tlpAtsHeatsinkEntryAn entry containing information applicable to a particular heatsink thermistor managed by this agent.
TlpAtsHeatsinkEntry
.1.3.6.1.4.1.850.1.1.3.4.3.6.1.1
tlpAtsHeatsinkIndexThe table row index for the ats heatsink thermistor.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.3.6.1.1.1
tlpAtsHeatsinkStatusIndicates whether the heatsink thermistor is available. The entry will return notAvailable(0) if a thermistor is either non-existent or disconnected, or available(1) when connected.ro
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.3.6.1.1.2
tlpAtsHeatsinkTemperatureCThe temperature at the heatsink termistor in tenths degrees Centigrade. Heatsink temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.ro
Integer32 UNITS "0.1 degrees Centigrade"
.1.3.6.1.4.1.850.1.1.3.4.3.6.1.1.3
tlpAtsHeatsinkTemperatureFThe temperature at the heatsink termistor in tenths degrees Farenheit. Heatsink temperature measurements are not supported on all models. If not supported, this value will always return ERROR_NO_SUCH_NAME.ro
Integer32 UNITS "0.1 degrees Farenheit"
.1.3.6.1.4.1.850.1.1.3.4.3.6.1.1.4
tlpAtsControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.4.4
tlpAtsControlTableThe actionable controls for each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss.
SEQUENCE OF TlpAtsControlEntry
.1.3.6.1.4.1.850.1.1.3.4.4.1
tlpAtsControlEntryAn entry containing controls for a particular ats.
TlpAtsControlEntry
.1.3.6.1.4.1.850.1.1.3.4.4.1.1
tlpAtsControlRampSet to TRUE to initiate the pre-designated ramp sequence on the ats.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.4.1.1.1
tlpAtsControlShedSet to TRUE to initiate the pre-designated shed sequence on the ats.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.4.1.1.2
tlpAtsControlAtsOnSet to TRUE to turn the ats on.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.4.1.1.3
tlpAtsControlAtsOffSet to TRUE to turn the ats off.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.4.1.1.4
tlpAtsControlAtsRebootSet to TRUE to reboot the ats.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.4.1.1.5
tlpAtsControlResetGeneralFaultSet to TRUE to reset the general fault alarm indicated by tlpAtsDeviceGeneralFault.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.1.3.4.4.1.1.6
tlpAtsConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.4.5
tlpAtsConfigTableThe configuration options of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss. Not all options are available on all atss.
SEQUENCE OF TlpAtsConfigEntry
.1.3.6.1.4.1.850.1.1.3.4.5.1
tlpAtsConfigEntryAn entry containing configuration options for a particular ats.
TlpAtsConfigEntry
.1.3.6.1.4.1.850.1.1.3.4.5.1.1
tlpAtsConfigInputVoltageThe nominal value of the input line voltage. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME. This value may not be writable on all models. If not writable, the value will be rejected and an appropriate error message will be returned.rw
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.5.1.1.1
tlpAtsConfigSourceSelectThe determination as to which of two AC input lines is designated as the primary input source. The other is designated as the secondary input source. This value will always return inputSourceA(1) for devices with a single input source. Setting this value is supported only on selected models.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.5.1.1.2
tlpAtsConfigSource1ReturnTimeThe nominal time to delay a transition to Source 1, if it is the preferred source.rw
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.5.1.1.3
tlpAtsConfigSource2ReturnTimeThe nominal time to delay a transition to Source 2, if it is the preferred source.rw
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.5.1.1.4
tlpAtsConfigAutoRampOnTransitionWhen enabled(1), the ats should perform its preconfigured ramp sequence when the input source transfers from its designated secondary source to its designated primary source. This value not supported on all ats devices. If not supported, then this value will always return ERROR_NO_SUCH_NAME.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.5.1.1.5
tlpAtsConfigAutoShedOnTransitionWhen enabled(1), the ats should perform its preconfigured shed sequence when the input source transfers from its designated primary source to its designated secondary source. This value not supported on all ats devices. If not supported, then this value will always return ERROR_NO_SUCH_NAME.rw
Enumeration
.1.3.6.1.4.1.850.1.1.3.4.5.1.1.6
tlpAtsConfigVoltageRangeTableThe voltage range options in this table is intended to configure the operating voltages of an ats. This is a sparse dependent table, and will contain some subset of devices that are atss. All voltage points defined in this table are listed in a specific order from high to low. All voltage points must satsify the conditions and ranges defined for each point. Any point violating any of the relative limits will be rejected. For optimal operation, it is recommended that tlpAtsConfigHighVoltageReset be set lower than tlpAtsConfigHighVoltageTransfer by a margin no less than 1% of tlpAtsConfigHighVoltageTransfer; and that tlpAtsConfigSource1TransferReset (tlpAtsConfigSource2TransferReset) be set higher than tlpAtsConfigSource1BrownoutSet (tlpAtsConfigSource2BrownoutSet) by a margin no less than 1% of tlpAtsConfigSource1BrownoutSet (tlpAtsConfigSource2BrownoutSet). *The upper limit of line voltage is tlpAtsInputHighTransferVoltageUpperBound. The lower limit of line voltage is tlpAtsInputBadTransferVoltageLowerBound. All minimum and maximum limits for each voltage point are all exlusive unless indicated otherwise.
SEQUENCE OF TlpAtsConfigVoltageRangeEntry
.1.3.6.1.4.1.850.1.1.3.4.5.2
tlpAtsConfigVoltageRangeEntryAn entry containing voltage range configuration options for a particular ats.
TlpAtsConfigVoltageRangeEntry
.1.3.6.1.4.1.850.1.1.3.4.5.2.1
tlpAtsConfigHighVoltageTransferThe maximum line voltage allowed before the unit disconnects the AC input connection. The maximum value allowed is dictated by tlpAtsInputHighTransferVoltageUpperBound (inclusively). The minimum value allowed is dictated by tlpAtsConfigHighVoltageReset. This value may not be configurable on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.4.5.2.1.1
tlpAtsConfigHighVoltageResetIf a unit is disconnected due to over-voltage, the line voltage has to fall below this value before the unit re-connects the AC input connection. The maximum value allowed is dictated by tlpAtsConfigHighVoltageTransfer. The minimum value allowed is dictated by the greater of tlpAtsConfigSource1TransferReset and tlpAtsConfigSource2TransferReset. If not supported, this value will return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.4.5.2.1.2
tlpAtsConfigSource1TransferResetIf input source 1 voltage level is above this value, a unit connected to source 2 will transition to source 1 (if it is the preferred source). The maximum value allowed is dictated by tlpAtsConfigHighVoltageReset. The minimum value allowed is dictated by tlpAtsConfigSource1BrownoutSet. If not supported, this value will return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.4.5.2.1.3
tlpAtsConfigSource1BrownoutSetThis value dictates the voltage level below which source 1 goes into a brown out condition. The maximum value allowed is dictated by tlpAtsConfigSource1TransferReset. The minimum value allowed is dictated by tlpAtsConfigSource1TransferSet. If not supported, this value will return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.4.5.2.1.4
tlpAtsConfigSource1TransferSetIf input source 1 voltage level falls below this value, a unit connected to source 1 will transition to source 2 (if it is in fair condition as denoted by tlpAtsConfigSource2TransferSet). The maximum value allowed is dictated by tlpAtsConfigSource1BrownoutSet. The minimum value allowed is dictated by tlpAtsConfigLowVoltageReset. If not supported, this value will return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.4.5.2.1.5
tlpAtsConfigSource2TransferResetIf input source 2 voltage level is above this value, a unit connected to source 1 will transition to source 2 (if it is the preferred source). The maximum value allowed is dictated by tlpAtsConfigHighVoltageReset. The minimum value allowed is dictated by tlpAtsConfigSource2BrownoutSet. If not supported, this value will return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.4.5.2.1.6
tlpAtsConfigSource2BrownoutSetThis value dictates the voltage level below which source 2 goes into a brown out condition. The maximum value allowed is dictated by tlpAtsConfigSource2TransferReset. The minimum value allowed is dictated by tlpAtsConfigSource2TransferSet. If not supported, this value will return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.4.5.2.1.7
tlpAtsConfigSource2TransferSetIf input source 2 voltage level falls below this value, a unit connected to source 2 will transition to source 1 (if it is in fair condition as denoted by tlpAtsConfigSource1TransferSet). The maximum value allowed is dictated by tlpAtsConfigSource2BrownoutSet. The minimum value allowed is dictated by tlpAtsConfigLowVoltageReset. If not supported, this value will return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.4.5.2.1.8
tlpAtsConfigLowVoltageResetIf a unit is disconnected due to under-voltage or is not powered up yet, the line voltage has to rise above this value before the unit gets connected to the AC input connection. The maximum value allowed is dictated by the lesser value of tlpAtsConfigSource1TransferSet and tlpAtsConfigSource2TransferSet. The minimum value allowed is dictated by tlpAtsConfigLowVoltageTransfer. If not supported, this value will return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.4.5.2.1.9
tlpAtsConfigLowVoltageTransferThe minimum line voltage allowed before the unit disconnects the AC input connection. The maximum value allowed is dictated by tlpAtsConfigLowVoltageReset. The minimum value allowed is dictated by tlpAtsInputBadTransferVoltageLowerBound (inclusively). If not supported, this value will return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.4.5.2.1.10
tlpAtsConfigVoltageRangeLimitsTableThe voltage range table, as documented by tlpAtsConfigVoltageRangeTable requires that all changes adhere with stack order, from high transfer voltage down to low transfer voltage. In addition to stack order, certain voltage range values have limits defining the absolute minimum and absolute maximum for such values. Any voltage value violating any respective limit defined herein will be rejected.
SEQUENCE OF TlpAtsConfigVoltageRangeLimitsEntry
.1.3.6.1.4.1.850.1.1.3.4.5.3
tlpAtsConfigVoltageRangeLimitsEntryAn entry containing voltage range limits configuration options for a particular ats.
TlpAtsConfigVoltageRangeLimitsEntry
.1.3.6.1.4.1.850.1.1.3.4.5.3.1
tlpAtsConfigSourceBrownoutSetMinimumThis value dictates the absolute lower limit by which tlpAtsConfigSource1BrownoutSet and tlpAtsConfigSource2BrownoutSet can be set. tlpAtsConfigSource1TransferSet and tlpAtsConfigSource2TransferSet, respectively, are also used when determining the lowest value a brownout value can be set at any given time. If not supported, this value will return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.4.5.3.1.1
tlpAtsConfigSourceBrownoutSetMaximumThis value dictates the absolute upper limit by which tlpAtsConfigSource1BrownoutSet and tlpAtsConfigSource2BrownoutSet can be set. tlpAtsConfigSource1TransferReset and tlpAtsConfigSource2TransferReset, respectively, are also used when determining the greatest value a brownout value can be set at any given time. If not supported, this value will return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.4.5.3.1.2
tlpAtsConfigSourceTransferSetMinimumThis value dictates the absolute lower limit by which tlpAtsConfigSource1TransferSet and tlpAtsConfigSource2TransferSet can be set. tlpAtsConfigLowVoltageReset is also used when determining the lowest value a transferset value can be set at any given time. If not supported, this value will return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.4.5.3.1.3
tlpAtsConfigSourceTransferSetMaximumThis value dictates the absolute upper limit by which tlpAtsConfigSource1TransferSet and tlpAtsConfigSource2TransferSet can be set. tlpAtsConfigSource1BrownoutSet and tlpAtsConfigSource2BrownoutSet, respectively, are also used when determining the greatest value a transferset value can be set at any given time. If not supported, this value will return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.4.5.3.1.4
tlpAtsConfigThresholdTableThe configurable threshold options of each ats in device table. This is a sparse dependent table, and will contain some subset of devices that are atss. Not all options are available on all atss.
SEQUENCE OF TlpAtsConfigThresholdEntry
.1.3.6.1.4.1.850.1.1.3.4.5.4
tlpAtsConfigThresholdEntryAn entry containing configurable threshold options for a particular ats.
TlpAtsConfigThresholdEntry
.1.3.6.1.4.1.850.1.1.3.4.5.4.1
tlpAtsConfigOverCurrentThresholdThe output current measurement at which an over current condition is reported. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "0.1 Amps"
.1.3.6.1.4.1.850.1.1.3.4.5.4.1.1
tlpAtsConfigOverTemperatureThresholdThe system temperature at which an over temperature condition is reported. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "0.1 Centigrade"
.1.3.6.1.4.1.850.1.1.3.4.5.4.1.2
tlpAtsConfigOverVoltageThresholdThe input voltage measurement at which an over voltage condition is reported. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.rw
Unsigned32 UNITS "0.1 Volts"
.1.3.6.1.4.1.850.1.1.3.4.5.4.1.3
tlpAtsConfigOverLoadThresholdThe system load at which an overload condition is reported. This value may not be supported on all models. If not supported, this value will return ERROR_NO_SUCH_NAME.rw
Unsigned32
.1.3.6.1.4.1.850.1.1.3.4.5.4.1.4
tlpCooling
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.5
tlpCoolingIdent
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.5.1
tlpCoolingIdentNumCoolingThe number of cooling devices that this agent is currently managing.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.5.1.1
tlpCoolingDevice
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.5.2
tlpCoolingDetail
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.5.3
tlpCoolingInput
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.5.3.1
tlpCoolingOutput
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.5.3.2
tlpCoolingControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.5.4
tlpCoolingConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.5.5
tlpKvm
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.6
tlpKvmIdent
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.6.1
tlpKvmIdentNumKvmThe number of kvm devices that this agent is currently managing.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.6.1.1
tlpKvmDevice
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.6.2
tlpKvmDetail
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.6.3
tlpKvmControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.6.4
tlpKvmConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.6.5
tlpRackTrack
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.7
tlpRackTrackIdent
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.7.1
tlpRackTrackIdentNumRackTrackThe number of rack track devices that this agent is currently managing.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.7.1.1
tlpRackTrackDevice
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.7.2
tlpRackTrackDetail
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.7.3
tlpRackTrackControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.7.4
tlpRackTrackConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.7.5
tlpSwitch
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.8
tlpSwitchIdent
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.8.1
tlpSwitchIdentNumSwitchThe number of switch devices that this agent is currently managing.ro
Unsigned32
.1.3.6.1.4.1.850.1.1.3.8.1.1
tlpSwitchDevice
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.8.2
tlpSwitchDetail
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.8.3
tlpSwitchControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.8.4
tlpSwitchConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.1.3.8.5
tlpSoftware
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.2
tlpAgentDetails
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.2.1
tlpAgentIdent
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.2.1.1
tlpAgentTypeThe type of PowerAlert engine providing this data.ro
Enumeration
.1.3.6.1.4.1.850.1.2.1.1.1
tlpAgentVersionThe version of the agent software.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.1.2
tlpAgentDriverVersionThe driver version of the agent software.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.1.3
tlpAgentMACThe MAC Address of the agent.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.1.4
tlpAgentSerialNumSerial number of the web card providing the agent data. This value is only supported by a web card agent. PowerAlert for PC (PAL) agents do not support this value and will return ERROR_NO_SUCH_NAME.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.1.5
tlpAgentUuidUniversally unique identifier for this host in the form 8-4-4-4-12 for a total of 36 characters (32 alphanumeric characters and four hyphens). For example: 550e8400-e29b-41d4-a716-446655440000.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.1.6
tlpAgentAttributes
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.2.1.2
tlpAgentAttributesSupports
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.2.1.2.1
tlpAgentAttributesSupportsHTTPIndicates whether the agent supports HTTP connections.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.1.1
tlpAgentAttributesSupportsHTTPSIndicates whether the agent supports HTTPS connections.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.1.2
tlpAgentAttributesSupportsFTPIndicates whether the agent supports FTP connections.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.1.3
tlpAgentAttributesSupportsTelnetMenuIndicates whether the agent supports Telnet menu connections.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.1.4
tlpAgentAttributesSupportsTelnetCLIIndicates whether the agent supports Telnet CLI connections.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.1.5
tlpAgentAttributesSupportsSSHMenuIndicates whether the agent supports SSH menu connections.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.1.6
tlpAgentAttributesSupportsSSHCLIIndicates whether the agent supports SSH CLI connections.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.1.7
tlpAgentAttributesSupportsSNMPIndicates whether the agent supports SNMP connections.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.1.8
tlpAgentAttributesSupportsSNMPTrapIndicates whether the agent supports listening for SNMP traps. This is only applicable for network monitoring applications, PowerAlert Shutdown Agent for an example, that connect to a web card or PowerAlert Local and listen for outbound traps. As such, this value is not supported and will always return 2(false) for a web card or PowerAlert Local.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.1.9
tlpAgentAttributesAutostart
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.2.1.2.2
tlpAgentAttributesAutostartHTTPIndicates whether the agent autostarts HTTP services.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.2.1
tlpAgentAttributesAutostartHTTPSIndicates whether the agent autostarts HTTPS services.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.2.2
tlpAgentAttributesAutostartFTPIndicates whether the agent autostarts FTP services.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.2.3
tlpAgentAttributesAutostartTelnetMenuIndicates whether the agent autostarts Telnet menu services.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.2.4
tlpAgentAttributesAutostartTelnetCLIIndicates whether the agent autostarts Telnet CLI services.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.2.5
tlpAgentAttributesAutostartSSHMenuIndicates whether the agent autostarts SSH menu services.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.2.6
tlpAgentAttributesAutostartSSHCLIIndicates whether the agent autostarts SSH CLI services.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.2.7
tlpAgentAttributesAutostartSNMPIndicates whether the agent autostarts SNMP services.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.2.8
tlpAgentAttributesSnmp
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.2.1.2.3
tlpAgentAttributesSNMPv1EnabledIndicates whether the agent will allow SNMPv1 connections.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.3.1
tlpAgentAttributesSNMPv2cEnabledIndicates whether the agent will allow SNMPv2c connections.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.3.2
tlpAgentAttributesSNMPv3EnabledIndicates whether the agent will allow SNMPv3 connections.ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.1.2.3.3
tlpAgentAttributesPorts
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.2.1.2.4
tlpAgentAttributesHTTPPortThe port used for HTTP communications.ro
Unsigned32
.1.3.6.1.4.1.850.1.2.1.2.4.1
tlpAgentAttributesHTTPSPortThe port used for HTTPS communications.ro
Unsigned32
.1.3.6.1.4.1.850.1.2.1.2.4.2
tlpAgentAttributesFTPPortThe port used for FTP communications.ro
Unsigned32
.1.3.6.1.4.1.850.1.2.1.2.4.3
tlpAgentAttributesTelnetMenuPortThe port used for Telnet Menu communications.ro
Unsigned32
.1.3.6.1.4.1.850.1.2.1.2.4.4
tlpAgentAttributesTelnetCLIPortThe port used for Telnet CLI communications.ro
Unsigned32
.1.3.6.1.4.1.850.1.2.1.2.4.5
tlpAgentAttributesSSHMenuPortThe port used for SSH Menu communications.ro
Unsigned32
.1.3.6.1.4.1.850.1.2.1.2.4.6
tlpAgentAttributesSSHCLIPortThe port used for SSH CLI communications.ro
Unsigned32
.1.3.6.1.4.1.850.1.2.1.2.4.7
tlpAgentAttributesSNMPPortThe port used for SNMP communications.ro
Unsigned32
.1.3.6.1.4.1.850.1.2.1.2.4.8
tlpAgentAttributesSNMPTrapPortThe port used for SNMP trap and notifications.ro
Unsigned32
.1.3.6.1.4.1.850.1.2.1.2.4.9
tlpAgentSettings
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.2.2
tlpAgentConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.2.2.1
tlpAgentConfigRemoteRegistrationRegisters an SNMP contact's IP address and the port on which the contact is listening for SNMP traps. Setting this value is used to CREATE a table entry in a non-standard way. Getting this value will return a string INADDR_ANY and any port number. The port number should always be included. When unregistering an SNMP contact, the requester's IP address should be provided with a port number of 0. When setting or unsetting this OID, the IP address string should never be 0 nor should it be empty. The registration uses its default community string to register each contact. To use a community other than the default, then it must be appended to the end of the string delimited with a comma. The address should be of the format 0.0.0.0:00000 for IPv4. If IPv6 is supported, use the bracket-enclosed format given in IETF RFC 2732 Section 2, with the following examples: [FEDC:BA98:7654:3210:FEDC:BA98:7654:3210]:80 [1080:0:0:0:8:800:200C:417A]:162 [3ffe:2a00:100:7031::1]:162 [1080::8:800:200C:417A]:162,myCommunity [::192.9.5.5]:162,myCommunity [::FFFF:129.144.52.38]:80 [2010:836B:4179::836B:4179]:162rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.2.1.1
tlpAgentConfigCurrentTimeThe current date and time of the system.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.2.1.2
tlpAgentContacts
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.2.3
tlpAgentEmailContacts
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.2.3.1
tlpAgentNumEmailContactsThe number of email contacts currently defined in the agent.ro
Unsigned32
.1.3.6.1.4.1.850.1.2.3.1.1
tlpAgentEmailContactTableA list of email contact entries. The number of entries is given by the value of tlpAgentNumEmailContacts.
SEQUENCE OF TlpAgentEmailContactEntry
.1.3.6.1.4.1.850.1.2.3.1.2
tlpAgentEmailContactEntryAn entry containing the details of an email contact.
TlpAgentEmailContactEntry
.1.3.6.1.4.1.850.1.2.3.1.2.1
tlpAgentEmailContactIndexThe table row index for the email contact.ro
Unsigned32
.1.3.6.1.4.1.850.1.2.3.1.2.1.1
tlpAgentEmailContactRowStatusRow status for the tlpAgentEmailContactTable.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.3.1.2.1.2
tlpAgentEmailContactNameThe name of the email contact.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.3.1.2.1.3
tlpAgentEmailContactAddressThe address of the email contact.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.3.1.2.1.4
tlpAgentSnmpContacts
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.2.3.2
tlpAgentNumSnmpContactsThe number of SNMP contacts currently defined in the agent.ro
Unsigned32
.1.3.6.1.4.1.850.1.2.3.2.1
tlpAgentSnmpContactTableA list of SNMP contact entries. The number of entries is given by the value of tlpAgentNumSnmpContacts.
SEQUENCE OF TlpAgentSnmpContactEntry
.1.3.6.1.4.1.850.1.2.3.2.2
tlpAgentSnmpContactEntryAn entry containing the details of an SNMP contact.
TlpAgentSnmpContactEntry
.1.3.6.1.4.1.850.1.2.3.2.2.1
tlpAgentSnmpContactIndexThe table row index for the SNMP contact.ro
Unsigned32
.1.3.6.1.4.1.850.1.2.3.2.2.1.1
tlpAgentSnmpContactRowStatusRow status for the tlpAgentSnmpContactTable.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.3.2.2.1.2
tlpAgentSnmpContactNameThe name of the SNMP contact.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.3.2.2.1.3
tlpAgentSnmpContactIpAddressThe IP address of the SNMP contact.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.3.2.2.1.4
tlpAgentSnmpContactPortThe port of the SNMP contact.rw
Unsigned32
.1.3.6.1.4.1.850.1.2.3.2.2.1.5
tlpAgentSnmpContactSnmpVersionThe SNMP contact version to use for sending traps.rw
Enumeration
.1.3.6.1.4.1.850.1.2.3.2.2.1.6
tlpAgentSnmpContactSecurityNameThe security name for the SNMP contact.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.3.2.2.1.7
tlpAgentSnmpContactPrivPasswordThe privacy password to use for sending V3 traps to the SNMP contact.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.3.2.2.1.8
tlpAgentSnmpContactAuthPasswordThe authentication password to use for sending V3 traps to the SNMP contact.rw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.2.3.2.2.1.9
tlpAlarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3
tlpAlarmsPresentThe present number of active alarm conditions.ro
Unsigned32
.1.3.6.1.4.1.850.1.3.1
tlpAlarmTableA list of alarm conditions for all devices managed by this agent. This table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect or conditions not acnowledged. The agent creates a row in the table each time a condition is detected and deletes that row when that condition no longer pertains (becomes inactive and is acknowledged). The agent creates the first row with tlpAlarmId equal to 1, and increments the value of tlpAlarmId each time a new row is created, wrapping to the first free value greater than or equal to 1 when the maximum value of tlpAlarmId would otherwise be exceeded. Consequently, after multiple operations, the table may become sparse (e.g., containing entries for rows 95, 100, 101, and 203) and the entries should not be assumed to be in chronological order because tlpAlarmId might have wrapped. The number of rows in the table at any given time is reflected by the value of tlpAlarmsPresent.
SEQUENCE OF TlpDeviceAlarmEntry
.1.3.6.1.4.1.850.1.3.2
tlpAlarmEntryAn entry containing information application to a particular alarm.
TlpDeviceAlarmEntry
.1.3.6.1.4.1.850.1.3.2.1
tlpAlarmIdA unique identifier for an alarm condition. This value will remain constant for the duration of the alarm condition.ro
Unsigned32
.1.3.6.1.4.1.850.1.3.2.1.1
tlpAlarmDescrA reference of the alarm description object. The object referenced should not be accessbile, but rather be used to provide a unique description for the alarm condition. The object referenced will be a well known alarm object associated with the device on which the alarm condition is active.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.2.1.2
tlpAlarmTimeThe value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before agent startup, the value of tlpAlarmsTime shall equal 0.ro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.850.1.3.2.1.3
tlpAlarmTableRefThis value references the OID of a table object applicable to the alarm condition. This, in conjunction with the table row as defined by tlpAlarmTableRowRef, specifies the object/row within this table to which the alarm condition applies. Example 1 -- The following sample values will be returned for a UPS on battery: tlpAlarmId 28 tlpAlarmDescr tlpUpsAlarmOnBattery tlpAlarmTime 12345678 tlpAlarmTableRef tlpDeviceTable tlpAlarmTableRowRef tlpDeviceIndex.2 tlpAlarmDetail On Battery tlpAlarmType warning tlpAlarmState active tlpAlarmAcknowledged notAcknowledged In the above example, tlpAlarmTableRef references the device table and tlpAlarmTableRowRef references the 2nd managed device in that table. Example 2 -- The following sample values will be returned for a PDU with a load turned off: tlpAlarmId 46 tlpAlarmDescr tlpPduAlarmLoadOff tlpAlarmTime 12345678 tlpAlarmTableRef tlpPduOutletTable tlpAlarmTableRowRef tlpOutletIndex.1.4 tlpAlarmDetail Load Off tlpAlarmType warning tlpAlarmState active tlpAlarmAcknowledged acknowledged In the above example, tlpAlarmTableRef references the pdu outlet table and tlpAlarmTableRowRef references the 4th outlet on the 1st managed device.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.2.1.4
tlpAlarmTableRowRefThis value is used in conjunction with tlpAlarmTableRef to define the object associated with this alarm condition. See the description of tlpAlarmTableRef for more information.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.2.1.5
tlpAlarmDetailA textual description of the alarm condition.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.3.2.1.6
tlpAlarmTypeThe category/group of this alarm.ro
Enumeration
.1.3.6.1.4.1.850.1.3.2.1.7
tlpAlarmStateThe current state of this alarm condition. An active(1) alarm is a condition that currently exists. An inactive(2) alarm is a condition that no longer exists because the alarm either cleared or was resolved. Each alarm condition must be cleared and acknowledged before it is removed from this table (see tlpAlarmAcknowledged).ro
Enumeration
.1.3.6.1.4.1.850.1.3.2.1.8
tlpAlarmAcknowledgedDenotes whether the alarm condition has been acknowledged. The agent will return notAcknowledged(1) if the condition has not been acknowledged, or acknowledged(2) when acknowledged. Writing the value acknowledged(2) for an alarm acknowledges the alarm condition. Each alarm condition must be cleared and acknowledged before it is removed from this table; therefore, even if acknowledged, the alarm will remain in this table until the alarm becomes inactive as denoted by tlpAlarmState.rw
Enumeration
.1.3.6.1.4.1.850.1.3.2.1.9
tlpAlarmsWellKnown
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3
tlpAgentAlarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.1
tlpDeviceAlarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.2
tlpAlarmCommunicationsLostA problem has been encountered in the communications between the agent and the device.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.2.1
tlpAlarmUserDefined
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.2.2
tlpAlarmUserDefined01User-defined event 1 is in alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.2.2.1
tlpAlarmUserDefined02User-defined event 2 is in alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.2.2.2
tlpAlarmUserDefined03User-defined event 3 is in alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.2.2.3
tlpAlarmUserDefined04User-defined event 4 is in alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.2.2.4
tlpAlarmUserDefined05User-defined event 5 is in alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.2.2.5
tlpAlarmUserDefined06User-defined event 6 is in alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.2.2.6
tlpAlarmUserDefined07User-defined event 7 is in alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.2.2.7
tlpAlarmUserDefined08User-defined event 8 is in alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.2.2.8
tlpAlarmUserDefined09User-defined event 9 is in alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.2.2.9
tlpUpsAlarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3
tlpUpsAlarmBatteryBadOne or more batteries have been determined to require replacement.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.1
tlpUpsAlarmOnBatteryThe UPS is drawing power from the batteries.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.2
tlpUpsAlarmLowBatteryThe remaining battery charge is less than or equal to the percentage of capacity warning specified by tlpUpsConfigBatteryCapacityThreshold.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.3
tlpUpsAlarmDepletedBatteryThe UPS will be unable to sustain the present load when and if the utility power is lost.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.4
tlpUpsAlarmTempBadA temperature is out of tolerance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.5
tlpUpsAlarmInputBadAn input condition is out of tolerance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.6
tlpUpsAlarmOutputBadAn output condition (other than OutputOverload) is out of tolerance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.7
tlpUpsAlarmOutputOverloadThe output load exceeds the UPS output capacity.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.8
tlpUpsAlarmOnBypassThe Bypass is presently engaged on the UPS.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.9
tlpUpsAlarmBypassBadThe Bypass is out of tolerance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.10
tlpUpsAlarmOutputOffAsRequestedThe UPS has shutdown as requested, i.e., the output is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.11
tlpUpsAlarmUpsOffAsRequestedThe entire UPS has shutdown as commanded.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.12
tlpUpsAlarmChargerFailedAn uncorrected problem has been detected within the UPS charger subsystem.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.13
tlpUpsAlarmUpsOutputOffThe output of the UPS is in the off state.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.14
tlpUpsAlarmUpsSystemOffThe UPS system is in the off state.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.15
tlpUpsAlarmFanFailureThe failure of one or more fans in the UPS has been detected.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.16
tlpUpsAlarmFuseFailureThe failure of one or more fuses has been detected.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.17
tlpUpsAlarmGeneralFaultA general fault in the UPS has been detected.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.18
tlpUpsAlarmDiagnosticTestFailedThe result of the last diagnostic test indicates a failure.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.19
tlpUpsAlarmAwaitingPowerThe UPS output is off and the UPS is awaiting the return of input power.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.20
tlpUpsAlarmShutdownPendingA tlpUpsShutdownAfterDelay countdown is underway.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.21
tlpUpsAlarmShutdownImminentThe UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.22
tlpUpsAlarmLoadLevelAboveThreshold
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.23
tlpUpsAlarmLoadLevelAboveThresholdTotalThe total load level is above the designated threshold.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.23.1
tlpUpsAlarmLoadLevelAboveThresholdPhase1The load level on phase 1 exceeds load limits.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.23.2
tlpUpsAlarmLoadLevelAboveThresholdPhase2The load level on phase 2 exceeds load limits.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.23.3
tlpUpsAlarmLoadLevelAboveThresholdPhase3The load level on phase 3 exceeds load limits.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.23.4
tlpUpsAlarmOutputCurrentChangedThe output current changed from its last known value.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.24
tlpUpsAlarmBatteryAgeAboveThresholdOne or more batteries have been determined to require replacement.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.25
tlpUpsAlarmLoadOff
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26
tlpUpsAlarmLoadOff01Load 1 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.1
tlpUpsAlarmLoadOff02Load 2 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.2
tlpUpsAlarmLoadOff03Load 3 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.3
tlpUpsAlarmLoadOff04Load 4 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.4
tlpUpsAlarmLoadOff05Load 5 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.5
tlpUpsAlarmLoadOff06Load 6 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.6
tlpUpsAlarmLoadOff07Load 7 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.7
tlpUpsAlarmLoadOff08Load 8 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.8
tlpUpsAlarmLoadOff09Load 9 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.9
tlpUpsAlarmLoadOff10Load 10 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.10
tlpUpsAlarmLoadOff11Load 11 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.11
tlpUpsAlarmLoadOff12Load 12 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.12
tlpUpsAlarmLoadOff13Load 13 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.13
tlpUpsAlarmLoadOff14Load 14 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.14
tlpUpsAlarmLoadOff15Load 15 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.15
tlpUpsAlarmLoadOff16Load 16 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.16
tlpUpsAlarmLoadOff17Load 17 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.17
tlpUpsAlarmLoadOff18Load 18 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.18
tlpUpsAlarmLoadOff19Load 19 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.19
tlpUpsAlarmLoadOff20Load 20 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.20
tlpUpsAlarmLoadOff21Load 21 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.21
tlpUpsAlarmLoadOff22Load 22 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.22
tlpUpsAlarmLoadOff23Load 23 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.23
tlpUpsAlarmLoadOff24Load 24 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.24
tlpUpsAlarmLoadOff25Load 25 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.25
tlpUpsAlarmLoadOff26Load 26 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.26
tlpUpsAlarmLoadOff27Load 27 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.27
tlpUpsAlarmLoadOff28Load 28 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.28
tlpUpsAlarmLoadOff29Load 29 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.29
tlpUpsAlarmLoadOff30Load 30 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.30
tlpUpsAlarmLoadOff31Load 31 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.31
tlpUpsAlarmLoadOff32Load 32 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.32
tlpUpsAlarmLoadOff33Load 33 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.33
tlpUpsAlarmLoadOff34Load 34 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.34
tlpUpsAlarmLoadOff35Load 35 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.35
tlpUpsAlarmLoadOff36Load 36 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.36
tlpUpsAlarmLoadOff37Load 37 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.37
tlpUpsAlarmLoadOff38Load 38 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.38
tlpUpsAlarmLoadOff39Load 39 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.39
tlpUpsAlarmLoadOff40Load 40 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.26.40
tlpUpsAlarmCurrentAboveThreshold
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.27
tlpUpsAlarmCurrentAboveThreshold1The output current on phase 1 exceeds load limits.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.27.1
tlpUpsAlarmCurrentAboveThreshold2The output current on phase 2 exceeds load limits.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.27.2
tlpUpsAlarmCurrentAboveThreshold3The output current on phase 3 exceeds load limits.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.27.3
tlpUpsAlarmRuntimeBelowWarningLevelThe battery seconds remaining is below warning level.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.28
tlpUpsAlarmBusStartVoltageLowThe inverter start up bus voltage is too low.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.29
tlpUpsAlarmBusOverVoltageThe inverter bus voltage is too high.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.30
tlpUpsAlarmBusUnderVoltageThe inverter bus voltage is too low.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.31
tlpUpsAlarmBusVoltageUnbalancedThe inverter bus voltage is not balanced.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.32
tlpUpsAlarmInverterSoftStartBadThe inverter bus voltage cannot reach desired voltage within a specified duration.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.33
tlpUpsAlarmInverterOverVoltageThe inverter voltage is too high.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.34
tlpUpsAlarmInverterUnderVoltageThe inverter voltage is too low.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.35
tlpUpsAlarmInverterCircuitBadThe inverter output is shorted.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.36
tlpUpsAlarmBatteryOverVoltageThe battery voltage is too high.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.37
tlpUpsAlarmBatteryUnderVoltageThe battery voltage is too low.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.38
tlpUpsAlarmSiteWiringFaultThe utility input wiring is faulty.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.39
tlpUpsAlarmOverTemperatureProtectionThe over temperature protection is activated.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.40
tlpUpsAlarmOverChargedThe UPS is over charged.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.41
tlpUpsAlarmEPOActiveThe EPO is currently activate.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.42
tlpUpsAlarmBypassFrequencyBadThe bypass frequency is out of tolerance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.43
tlpUpsAlarmExternalSmartBatteryAgeAboveThresholdOne or more external smart batteries have been determined to require replacement.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.44
tlpUpsAlarmExternalNonSmartBatteryAgeAboveThresholdOne or more external non-smart batteries have been determined to require replacement.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.45
tlpUpsAlarmSmartBatteryCommLostCommunications with the smart batteries was lost.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.46
tlpUpsAlarmLoadsNotAllOnOne of more loads are not on.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.3.47
tlpPduAlarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4
tlpPduAlarmLoadLevelAboveThresholdThe load level is above the designated threshold.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.1
tlpPduAlarmInputBadAn input condition is out of tolerance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.2
tlpPduAlarmOutputBadAn output condition (other than OutputOverload) is out of tolerance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.3
tlpPduAlarmOutputOverloadThe output load exceeds the pdu output capacity.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.4
tlpPduAlarmOutputOffThe output of the pdu is in the off state.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.5
tlpPduAlarmLoadOff
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6
tlpPduAlarmLoadOff01Load 1 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.1
tlpPduAlarmLoadOff02Load 2 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.2
tlpPduAlarmLoadOff03Load 3 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.3
tlpPduAlarmLoadOff04Load 4 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.4
tlpPduAlarmLoadOff05Load 5 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.5
tlpPduAlarmLoadOff06Load 6 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.6
tlpPduAlarmLoadOff07Load 7 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.7
tlpPduAlarmLoadOff08Load 8 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.8
tlpPduAlarmLoadOff09Load 9 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.9
tlpPduAlarmLoadOff10Load 10 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.10
tlpPduAlarmLoadOff11Load 11 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.11
tlpPduAlarmLoadOff12Load 12 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.12
tlpPduAlarmLoadOff13Load 13 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.13
tlpPduAlarmLoadOff14Load 14 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.14
tlpPduAlarmLoadOff15Load 15 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.15
tlpPduAlarmLoadOff16Load 16 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.16
tlpPduAlarmLoadOff17Load 17 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.17
tlpPduAlarmLoadOff18Load 18 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.18
tlpPduAlarmLoadOff19Load 19 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.19
tlpPduAlarmLoadOff20Load 20 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.20
tlpPduAlarmLoadOff21Load 21 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.21
tlpPduAlarmLoadOff22Load 22 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.22
tlpPduAlarmLoadOff23Load 23 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.23
tlpPduAlarmLoadOff24Load 24 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.24
tlpPduAlarmLoadOff25Load 25 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.25
tlpPduAlarmLoadOff26Load 26 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.26
tlpPduAlarmLoadOff27Load 27 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.27
tlpPduAlarmLoadOff28Load 28 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.28
tlpPduAlarmLoadOff29Load 29 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.29
tlpPduAlarmLoadOff30Load 30 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.30
tlpPduAlarmLoadOff31Load 31 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.31
tlpPduAlarmLoadOff32Load 32 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.32
tlpPduAlarmLoadOff33Load 33 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.33
tlpPduAlarmLoadOff34Load 34 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.34
tlpPduAlarmLoadOff35Load 35 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.35
tlpPduAlarmLoadOff36Load 36 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.36
tlpPduAlarmLoadOff37Load 37 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.37
tlpPduAlarmLoadOff38Load 38 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.38
tlpPduAlarmLoadOff39Load 39 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.39
tlpPduAlarmLoadOff40Load 40 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.6.40
tlpPduAlarmCircuitBreakerOpen
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.7
tlpPduAlarmCircuitBreakerOpen01Circuit breaker 1 is open.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.7.1
tlpPduAlarmCircuitBreakerOpen02Circuit breaker 2 is open.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.7.2
tlpPduAlarmCircuitBreakerOpen03Circuit breaker 3 is open.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.7.3
tlpPduAlarmCircuitBreakerOpen04Circuit breaker 4 is open.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.7.4
tlpPduAlarmCircuitBreakerOpen05Circuit breaker 5 is open.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.7.5
tlpPduAlarmCircuitBreakerOpen06Circuit breaker 6 is open.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.7.6
tlpPduAlarmCurrentAboveThreshold
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.8
tlpPduAlarmCurrentAboveThreshold1The output current on phase 1 exceeds load limits.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.8.1
tlpPduAlarmCurrentAboveThreshold2The output current on phase 2 exceeds load limits.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.8.2
tlpPduAlarmCurrentAboveThreshold3The output current on phase 3 exceeds load limits.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.8.3
tlpPduAlarmLoadsNotAllOnOne of more loads are not on.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.4.9
tlpEnvAlarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.5
tlpEnvAlarmTemperatureBeyondLimitsThe temperature exceeds limits.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.5.1
tlpEnvAlarmHumidityBeyondLimitsThe humidity exceeds limits.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.5.2
tlpEnvAlarmInputContact
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.5.3
tlpEnvAlarmInputContact01Input contact 1 is in alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.5.3.1
tlpEnvAlarmInputContact02Input contact 2 is in alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.5.3.2
tlpEnvAlarmInputContact03Input contact 3 is in alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.5.3.3
tlpEnvAlarmInputContact04Input contact 4 is in alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.5.3.4
tlpEnvAlarmOutputContact
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.5.4
tlpEnvAlarmOutputContact01Output contact 1 is in alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.5.4.1
tlpEnvAlarmOutputContact02Output contact 2 is in alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.5.4.2
tlpEnvAlarmOutputContact03Output contact 3 is in alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.5.4.3
tlpEnvAlarmOutputContact04Output contact 4 is in alarm.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.5.4.4
tlpAtsAlarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6
tlpAtsAlarmOutage
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.1
tlpAtsAlarmSource1OutageInput on source 1 is not present. For atss with the designation of primary and secondary, this alarm denotes input on the primary source is not present.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.1.1
tlpAtsAlarmSource2OutageInput on source 2 is not present. For atss with the designation of primary and secondary, this alarm denotes input on the secondary source is not present.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.1.2
tlpAtsAlarmTemperature
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.2
tlpAtsAlarmSystemTemperatureThe system temperature is out of tolerance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.2.1
tlpAtsAlarmSource1TemperatureThe source 1 temperature is out of tolerance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.2.2
tlpAtsAlarmSource2TemperatureThe source 2 temperature is out of tolerance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.2.3
tlpAtsAlarmLoadLevelAboveThresholdThe load level is above the designated threshold.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.3
tlpAtsAlarmInputBadAn input condition is out of tolerance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.4
tlpAtsAlarmOutputBadAn output condition (other than OutputOverload) is out of tolerance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.5
tlpAtsAlarmOutputOverloadThe output load exceeds the ats output capacity.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.6
tlpAtsAlarmOutputOffThe output of the ats is in the off state.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.7
tlpAtsAlarmLoadOff
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8
tlpAtsAlarmLoadOff01Load 1 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.1
tlpAtsAlarmLoadOff02Load 2 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.2
tlpAtsAlarmLoadOff03Load 3 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.3
tlpAtsAlarmLoadOff04Load 4 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.4
tlpAtsAlarmLoadOff05Load 5 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.5
tlpAtsAlarmLoadOff06Load 6 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.6
tlpAtsAlarmLoadOff07Load 7 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.7
tlpAtsAlarmLoadOff08Load 8 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.8
tlpAtsAlarmLoadOff09Load 9 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.9
tlpAtsAlarmLoadOff10Load 10 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.10
tlpAtsAlarmLoadOff11Load 11 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.11
tlpAtsAlarmLoadOff12Load 12 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.12
tlpAtsAlarmLoadOff13Load 13 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.13
tlpAtsAlarmLoadOff14Load 14 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.14
tlpAtsAlarmLoadOff15Load 15 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.15
tlpAtsAlarmLoadOff16Load 16 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.16
tlpAtsAlarmLoadOff17Load 17 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.17
tlpAtsAlarmLoadOff18Load 18 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.18
tlpAtsAlarmLoadOff19Load 19 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.19
tlpAtsAlarmLoadOff20Load 20 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.20
tlpAtsAlarmLoadOff21Load 21 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.21
tlpAtsAlarmLoadOff22Load 22 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.22
tlpAtsAlarmLoadOff23Load 23 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.23
tlpAtsAlarmLoadOff24Load 24 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.24
tlpAtsAlarmLoadOff25Load 25 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.25
tlpAtsAlarmLoadOff26Load 26 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.26
tlpAtsAlarmLoadOff27Load 27 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.27
tlpAtsAlarmLoadOff28Load 28 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.28
tlpAtsAlarmLoadOff29Load 29 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.29
tlpAtsAlarmLoadOff30Load 30 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.30
tlpAtsAlarmLoadOff31Load 31 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.31
tlpAtsAlarmLoadOff32Load 32 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.32
tlpAtsAlarmLoadOff33Load 33 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.33
tlpAtsAlarmLoadOff34Load 34 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.34
tlpAtsAlarmLoadOff35Load 35 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.35
tlpAtsAlarmLoadOff36Load 36 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.36
tlpAtsAlarmLoadOff37Load 37 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.37
tlpAtsAlarmLoadOff38Load 38 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.38
tlpAtsAlarmLoadOff39Load 39 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.39
tlpAtsAlarmLoadOff40Load 40 is off.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.8.40
tlpAtsAlarmCircuitBreakerOpen
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.9
tlpAtsAlarmCircuitBreakerOpen01Circuit breaker 1 is open.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.9.1
tlpAtsAlarmCircuitBreakerOpen02Circuit breaker 2 is open.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.9.2
tlpAtsAlarmCircuitBreakerOpen03Circuit breaker 3 is open.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.9.3
tlpAtsAlarmCircuitBreakerOpen04Circuit breaker 4 is open.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.9.4
tlpAtsAlarmCircuitBreakerOpen05Circuit breaker 5 is open.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.9.5
tlpAtsAlarmCircuitBreakerOpen06Circuit breaker 6 is open.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.9.6
tlpAtsAlarmCurrentAboveThreshold
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.10
tlpAtsAlarmCurrentAboveThresholdA1The output current on input source 1 phase 1 exceeds load limits.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.10.1
tlpAtsAlarmCurrentAboveThresholdA2The output current on input source 1 phase 2 exceeds load limits.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.10.2
tlpAtsAlarmCurrentAboveThresholdA3The output current on input source 1 phase 3 exceeds load limits.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.10.3
tlpAtsAlarmCurrentAboveThresholdB1The output current on input source 2 phase 1 exceeds load limits.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.10.4
tlpAtsAlarmCurrentAboveThresholdB2The output current on input source 2 phase 2 exceeds load limits.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.10.5
tlpAtsAlarmCurrentAboveThresholdB3The output current on input source 2 phase 3 exceeds load limits.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.10.6
tlpAtsAlarmLoadsNotAllOnOne of more loads are not on.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.11
tlpAtsAlarmGeneralFaultA general fault in the ats has been detected.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.12
tlpAtsAlarmVoltage
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.13
tlpAtsAlarmOverVoltageThe input voltage is out of tolerance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.13.1
tlpAtsAlarmSource1OverVoltageThe voltage on source 1 is out of tolerance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.13.2
tlpAtsAlarmSource2OverVoltageThe voltage on source 2 is out of tolerance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.13.3
tlpAtsAlarmFrequency
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.14
tlpAtsAlarmSource1InvalidFrequencyThe voltage on source 1 is out of tolerance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.14.1
tlpAtsAlarmSource2InvalidFrequencyThe voltage on source 2 is out of tolerance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.6.14.2
tlpCoolingAlarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7
tlpCoolingAlarmSupplyAirSensorFaultThe supply air sensor is in fault.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.1
tlpCoolingAlarmReturnAirSensorFaultThe return air sensor is in fault.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.2
tlpCoolingAlarmCondenserInletAirSensorFaultThe condenser inlet air sensor is in fault.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.3
tlpCoolingAlarmCondenserOutletAirSensorFaultThe condenser outlet air sensor is in fault.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.4
tlpCoolingAlarmSuctionTemperatureSensorFaultThe suction temperature sensor is in fault.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.5
tlpCoolingAlarmEvaporatorTemperatureSensorFaultThe evaporator temperature sensor is in fault.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.6
tlpCoolingAlarmAirFilterCloggedThe air filter is clogged.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.7
tlpCoolingAlarmAirFilterRunHoursViolationThe air filter run hours was violated.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.8
tlpCoolingAlarmSuctionPressureSensorFaultThe suction pressure sensor is in fault.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.9
tlpCoolingAlarmInverterCommunicationsFaultThe inverter communications is in fault.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.10
tlpCoolingAlarmRemoteShutdownViaInputContactA remote shutdown was triggerd by an input contact.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.11
tlpCoolingAlarmCondensatePumpFaultThe condensate pump is in fault.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.12
tlpCoolingAlarmLowRefrigerantStartupFaultThe low refrigerant startup is in fault.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.13
tlpCoolingAlarmCondenserFanFaultThe condenser fan is in fault.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.14
tlpCoolingAlarmCondenserFailureThe condenser has failed.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.15
tlpCoolingAlarmEvaporatorCoolingFailureThe evaporator cooling is in fault.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.16
tlpCoolingAlarmReturnAirTempHighThe return air temperature is high.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.17
tlpCoolingAlarmSupplyAirTempHighThe supply air temperature is high.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.18
tlpCoolingAlarmEvaporatorFailureThe evaporator has failed.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.19
tlpCoolingAlarmEvaporatorFreezeUpThe evaporator is frozen.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.20
tlpCoolingAlarmDischargePressureHighThe discharge pressure is high.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.21
tlpCoolingAlarmPressureGaugeFailureThe pressure gauge has failed.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.22
tlpCoolingAlarmDischargePressurePersistentHighThe discharge pressure is persistently high.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.23
tlpCoolingAlarmSuctionPressureLowStartFailureCannot start due to low suction pressure.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.24
tlpCoolingAlarmSuctionPressureLowThe suction pressure is low.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.25
tlpCoolingAlarmSuctionPressurePersistentLowThe suction pressure is persistently low.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.26
tlpCoolingAlarmStartupLinePressureImbalanceThe startup line pressure is in imbalance.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.27
tlpCoolingAlarmCompressorFailureThe compressor has failed.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.28
tlpCoolingAlarmCurrentLimitThe current is out of range.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.29
tlpCoolingAlarmWaterLeakWater is leaking.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.30
tlpCoolingAlarmFanUnderCurrentThe fan is under current.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.31
tlpCoolingAlarmFanOverCurrentThe fan is over current.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.32
tlpCoolingAlarmDischargePressureSensorFaultThe discharge pressure sensor is in fault.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.33
tlpCoolingAlarmWaterFullWater is Full.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.34
tlpCoolingAlarmAutoCoolingOnAutomatic cooling was activated to lower the temperature below the remote set point.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.35
tlpCoolingAlarmPowerButtonPressedPower button was pressed on the front panel.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.36
tlpCoolingAlarmDisconnectedFromDeviceThe device communications is disconnected.
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.7.37
tlpKvmAlarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.8
tlpRackTrackAlarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.9
tlpSwitchAlarms
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.3.10
tlpAlarmControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.4
tlpAlarmControlTableA list of alarm conditions supported for each device managed by this agent. This table contains zero, one, or many rows depending upon the number of available alarms managed by each device.
SEQUENCE OF TlpAlarmControlEntry
.1.3.6.1.4.1.850.1.3.4.1
tlpAlarmControlEntryAn entry containing details for a particular alarm condition.
TlpAlarmControlEntry
.1.3.6.1.4.1.850.1.3.4.1.1
tlpAlarmControlIndexThe table row index for this alarm control entry for this device. The index of any one row represents the index of the alarm entry within the agent system. As such, the index values for any one device is not guaranteed to start with 1 or be numerically sequential.ro
Unsigned32
.1.3.6.1.4.1.850.1.3.4.1.1.1
tlpAlarmControlDescrA reference of the alarm description object. The object referenced should not be accessbile, but rather be used to provide a unique description for the alarm condition. The object referenced will be a well known alarm object associated with the device on which the alarm condition is active. This will be the same object description of an alarm when in alarm as referenced by tlpAlarmDescr.ro
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.3.4.1.1.2
tlpAlarmControlDetailA textual description of the alarm condition. This will be the same textual description of an alarm when in alarm as referenced by tlpAlarmDetail.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.850.1.3.4.1.1.3
tlpAlarmControlSeverityThe severity of this alarm, which can be configured as desired for each alarm condition. This will be the same severity used when in alarm as referenced by tlpAlarmType.rw
Enumeration
.1.3.6.1.4.1.850.1.3.4.1.1.4
tlpNotify
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.4
tlpNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.850.1.4.1
tlpNotificationsAlarmEntryAddedThis notification is sent each time an alarm condition is inserted into the device alarm table, tlpAlarmTable.
NOTIFICATION-TYPE
.1.3.6.1.4.1.850.1.4.1.1
tlpNotificationsAlarmEntryRemovedThis notification is sent each time an alarm condition is removed from the device alarm table, tlpAlarmTable.
NOTIFICATION-TYPE
.1.3.6.1.4.1.850.1.4.1.2
tlpNotifySystemStartupUsed to inform another entity of an agent's startup. The varbinds that follow are: OBJ1 = tlpAgentType Obj1Value = The type of engine providing this data OBJ2 = tlpAgentVersion Obj2Value = The current version of the engine OBJ3 = tlpAgentMAC Obj3Value = The MAC address of the engine OBJ4 = tlpAgentSerialNum Obj4Value = The serial number of the web card [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlpDeviceNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlpDeviceNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlpDeviceManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlpDeviceModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlpDeviceName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlpDeviceLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlpDeviceRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlpDeviceProtocol, indexed by device Obj11Value= The device's protocol (display string format)
NOTIFICATION-TYPE
.1.3.6.1.4.1.850.1.4.1.3
tlpNotifySystemShutdownUsed to inform another entity of an agent's shutdown. The varbinds that follow are: OBJ1 = tlpAgentType Obj1Value = The type of engine providing this data OBJ2 = tlpAgentVersion Obj2Value = The current version of the engine OBJ3 = tlpAgentMAC Obj3Value = The MAC address of the engine OBJ4 = tlpAgentSerialNum Obj4Value = The serial number of the web card [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlpDeviceNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlpDeviceNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlpDeviceManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlpDeviceModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlpDeviceName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlpDeviceLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlpDeviceRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlpDeviceProtocol, indexed by device Obj11Value= The device's protocol (display string format)
NOTIFICATION-TYPE
.1.3.6.1.4.1.850.1.4.1.4
tlpNotifySystemUpdateUsed to inform another entity of an engine's startup. The varbinds that follow are: OBJ1 = tlpAgentType Obj1Value = The type of engine providing this data OBJ2 = tlpAgentVersion Obj2Value = The current version of the engine OBJ3 = tlpAgentMAC Obj3Value = The MAC address of the engine OBJ4 = tlpAgentSerialNum Obj4Value = The serial number of the web card [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlpDeviceNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlpDeviceNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlpDeviceManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlpDeviceModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlpDeviceName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlpDeviceLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlpDeviceRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlpDeviceProtocol, indexed by device Obj11Value= The device's protocol (display string format)
NOTIFICATION-TYPE
.1.3.6.1.4.1.850.1.4.1.5
TRIPPLITE-PRODUCTS - SNMP MIB Reference | MIBs Explorer