TRIPPLITE-12X
This MIB module defines MIB objects which provide mechanisms for remote management capabilities of Tripplite PowerAlert and related software.
Main OID:
tlPowerAlert.1.3.6.1.4.1.850.90
382
Objects
Active
Status
6
Dependencies
Imported Objects
Objects
382 total| Object Name |
|---|
tlEnumerations OBJECT IDENTIFIER .1.3.6.1.4.1.850.2 |
tlOperatingSystems OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1 |
hpux9 OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.1 |
sunos4 OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.2 |
solaris OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.3 |
osf OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.4 |
ultrix OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.5 |
hpux10 OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.6 |
netbsd1 OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.7 |
freebsd OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.8 |
irix OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.9 |
linux OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.10 |
bsdi OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.11 |
openbsd OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.12 |
win32 OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.13 |
hpux11 OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.14 |
win9x OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.50 |
winnt OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.51 |
solspark OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.52 |
solintel OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.53 |
aix OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.54 |
sco OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.55 |
osx OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.56 |
unknown OBJECT IDENTIFIER .1.3.6.1.4.1.850.2.1.255 |
tlConformance OBJECT IDENTIFIER .1.3.6.1.4.1.850.20 |
tlCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.850.20.1 |
tlGroups OBJECT IDENTIFIER .1.3.6.1.4.1.850.20.2 |
tlSubsetGroups OBJECT IDENTIFIER .1.3.6.1.4.1.850.20.2.1 |
tlBasicGroups OBJECT IDENTIFIER .1.3.6.1.4.1.850.20.2.2 |
tlFullGroups OBJECT IDENTIFIER .1.3.6.1.4.1.850.20.2.3 |
tlUpsFullGroups OBJECT IDENTIFIER .1.3.6.1.4.1.850.20.2.3.100 |
tlUpsFullIdentGroupThe tlUpsFullIdentGroup defines objects which are common to the Ident group of fully compliant Tripplite UPS's Unknown .1.3.6.1.4.1.850.20.2.3.100.1 |
tlUpsFullBatteryGroupThe tlUpsFullBatteryGroup defines objects which are common to the Battery group of fully compliant Tripplite UPS's Unknown .1.3.6.1.4.1.850.20.2.3.100.2 |
tlUpsFullAlarmGroup OBJECT IDENTIFIER .1.3.6.1.4.1.850.20.2.3.100.6 |
tlUpsFullAlarmObjsGroupThe tlUpsFullAlarmObjsGroup defines objects which are common to the Alarm group of fully compliant Tripplite UPS's Unknown .1.3.6.1.4.1.850.20.2.3.100.6.1 |
tlUpsFullTestGroupThe tlUpsFullTestGroup defines objects which are common to the Test group of fully compliant Tripplite UPS's Unknown .1.3.6.1.4.1.850.20.2.3.100.7 |
tlUpsFullControlGroupThe tlUpsFullControlGroup defines objects which are common to the Control group of fully compliant Tripplite UPS's Unknown .1.3.6.1.4.1.850.20.2.3.100.8 |
tlUpsFullConfigGroupThe tlUpsFullConfigGroup defines objects which are common to the Config group of fully compliant Tripplite UPS's Unknown .1.3.6.1.4.1.850.20.2.3.100.9 |
tlUpsFullOutletGroupThe tlUpsFullOutletGroup defines objects which are common to the Outlet group of fully compliant Tripplite UPS's Unknown .1.3.6.1.4.1.850.20.2.3.100.10 |
tlPowerAlertThis MIB module defines MIB objects which provide mechanisms for remote management capabilities of Tripplite PowerAlert and related software. MODULE-IDENTITY .1.3.6.1.4.1.850.90 |
tlPASystem OBJECT IDENTIFIER .1.3.6.1.4.1.850.90.1 |
tlPAContacts OBJECT IDENTIFIER .1.3.6.1.4.1.850.90.1.1 |
tlPAEmailContacts OBJECT IDENTIFIER .1.3.6.1.4.1.850.90.1.1.1 |
tlPANumberOfEmailContactsThe number email contacts currently defined.ro NonNegativeInteger (UPS-MIB) .1.3.6.1.4.1.850.90.1.1.1.1 |
tlPAEmailContactsTableA list email contact entries. The number of entries is given by the value of tlPANumberOfEmailContacts. SEQUENCE OF TlPAEmailContactEntry .1.3.6.1.4.1.850.90.1.1.1.2 |
tlPAEmailContactEntryAn entry containing email contacts information. TlPAEmailContactEntry .1.3.6.1.4.1.850.90.1.1.1.2.1 |
tlPAEmailContactIndexThis is the index number of the email contact.ro PositiveInteger (UPS-MIB) .1.3.6.1.4.1.850.90.1.1.1.2.1.1 |
tlPAEmailContactRowStatusThe row status for the tlPAEmailContactTable rowrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.850.90.1.1.1.2.1.2 |
tlPAEmailContactNameThe name of the email contact.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.90.1.1.1.2.1.3 |
tlPAEmailContactAddressThe address of the email contact.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.90.1.1.1.2.1.4 |
tlPASnmpContacts OBJECT IDENTIFIER .1.3.6.1.4.1.850.90.1.1.2 |
tlPANumberOfSnmpContactsThe number SNMP contacts currently defined.ro NonNegativeInteger (UPS-MIB) .1.3.6.1.4.1.850.90.1.1.2.1 |
tlPASnmpContactsTableA list SNMP contact entries. The number of entries is given by the value of tlPANumberOfSnmpContacts. SEQUENCE OF TlPASnmpContactEntry .1.3.6.1.4.1.850.90.1.1.2.2 |
tlPASnmpContactEntryAn entry containing SNMP contacts information. TlPASnmpContactEntry .1.3.6.1.4.1.850.90.1.1.2.2.1 |
tlPASnmpContactIndexThis is the index number of this SNMP contact.ro PositiveInteger (UPS-MIB) .1.3.6.1.4.1.850.90.1.1.2.2.1.1 |
tlPASnmpContactRowStatusThe row status for the tlPASnmpContactTable rowrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.850.90.1.1.2.2.1.2 |
tlPASnmpContactNameThe name of the SNMP contact.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.90.1.1.2.2.1.3 |
tlPASnmpContactIpAddressThe IP address of the SNMP contact.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.90.1.1.2.2.1.4 |
tlPASnmpContactPortThe port of the SNMP contact.rw PositiveInteger (UPS-MIB) .1.3.6.1.4.1.850.90.1.1.2.2.1.5 |
tlPASnmpContactSnmpVersionThe SNMP contact version to use for sending traps.rw Enumeration .1.3.6.1.4.1.850.90.1.1.2.2.1.6 |
tlPASnmpContactSecurityNameThe SNMP contact security name.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.90.1.1.2.2.1.7 |
tlPASnmpContactPrivPasswordThe SNMP contact priv password to use for sending V3 traps.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.90.1.1.2.2.1.8 |
tlPASnmpContactAuthPasswordThe SNMP contact auth password to use for sending V3 traps.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.90.1.1.2.2.1.9 |
tlUPS OBJECT IDENTIFIER .1.3.6.1.4.1.850.100 |
tlUpsObjects OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1 |
tlUpsIdent OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.1 |
tlUpsIdentUpsSoftwareChecksumA checksum for the UPS software.ro Integer32 .1.3.6.1.4.1.850.100.1.1.1 |
tlUpsIdentSerialNumSerial number for the UPS.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.1.2 |
tlUpsIdentIDA user-supplied ID for the UPS.rw Integer32 .1.3.6.1.4.1.850.100.1.1.3 |
tlUpsSnmpCardSerialNumSerial number for the UPS.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.1.4 |
tlUpsSelectedDeviceIDThe device ID selected to be used for retrieving data for this mib. As the snmp web card has only one device, this is read only for itrw Integer32 .1.3.6.1.4.1.850.100.1.1.5 |
tlUpsLocationThe device location string.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.1.6 |
tlUpsBattery OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.2 |
tlUpsBatteryAgeThe age of the battery in years. This is equal to the current date minus tlConfigBattReplDate.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.2.1 |
tlUpsTemperatureFThe temperature of the battery, in Farenheight degrees. This is calculated from upsBatteryTemperature, which is in Celsius degrees.ro Integer32 .1.3.6.1.4.1.850.100.1.2.2 |
tlUpsExternalBatteryAgeThe age of external battery in years. This is equal to the current date minus tlConfigExternalBattReplDate.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.2.3 |
tlUpsInput OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.3 |
tlUpsInputNumVoltagesThe number of input voltages. Phase to phase or phase to neutral. This variable indicates the number of rows in the input table.ro NonNegativeInteger (UPS-MIB) .1.3.6.1.4.1.850.100.1.3.1 |
tlUpsInputVoltageTableA list of voltage input table entries. The number of entries is given by the value of tlUpsInputNumVoltages. SEQUENCE OF TlUpsInputVoltageEntry .1.3.6.1.4.1.850.100.1.3.2 |
tlUpsInputVoltageEntryAn entry containing information applicable to a particular input voltage. TlUpsInputVoltageEntry .1.3.6.1.4.1.850.100.1.3.2.1 |
tlUpsInputVoltageIndexThe input voltage identifier. PositiveInteger (UPS-MIB) .1.3.6.1.4.1.850.100.1.3.2.1.1 |
tlUpsInputVoltageTypeWhether voltage measured is phase to phase or phase to neutral.ro Enumeration .1.3.6.1.4.1.850.100.1.3.2.1.2 |
tlUpsInputVoltageThe magnitude of the present input voltage. A value of 6553 indicates Unknown.ro NonNegativeInteger UNITS "RMS Volts" .1.3.6.1.4.1.850.100.1.3.2.1.3 |
tlUpsInputSourceSelectThe determination as to which of two AC input lines is designated as the primary input source. The other is designated as the secondary input source. This value will always return inputSourceA(0) for devices with a single input source. Setting this value is supported only on selected models.rw Enumeration .1.3.6.1.4.1.850.100.1.3.3 |
tlUpsPhaseImbalancePercentage of imbalance of the 3 phases.ro INTEGER UNITS "Percent" .1.3.6.1.4.1.850.100.1.3.4 |
tlUpsInputSourceAvailabilityThe determination as to which of two AC input lines are available. The agent will return either inputSourceA(1) or inputSourceB(2) if only one line is available, or inputSourceAB(3) if both lines are available. The agent will never return none(0) since the device will be powered off if neither line is available.ro Enumeration .1.3.6.1.4.1.850.100.1.3.5 |
tlUpsInputSourceInUseThe determination as to which one of two AC input lines is in use.ro Enumeration .1.3.6.1.4.1.850.100.1.3.6 |
tlUpsInputSourceTransitionCountThe number of times the device transitions between primary and secondary sources. Most devices are limied to 65533 transitions, after which the value will not increment.ro PositiveInteger (UPS-MIB) .1.3.6.1.4.1.850.100.1.3.7 |
tlUpsOutput OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.4 |
tlUpsOutputPowerTotalThe power capacity of the device.ro PositiveInteger (UPS-MIB) .1.3.6.1.4.1.850.100.1.4.5 |
tlUpsOutputCircuitsThe number of output circuits. This variable indicates the number of rows in the output circuit table.ro NonNegativeInteger (UPS-MIB) .1.3.6.1.4.1.850.100.1.4.6 |
tlUpsOutputCircuitTableA list of output currents table entries. The number of entries is given by the value of tlUpsOutputNumCircuits. SEQUENCE OF TlUpsOutputCircuitEntry .1.3.6.1.4.1.850.100.1.4.7 |
tlUpsOutputCircuitEntryAn entry containing information applicable to a particular output circuit. TlUpsOutputCircuitEntry .1.3.6.1.4.1.850.100.1.4.7.1 |
tlUpsOutputCircuitIndexThe output circuit identifier. PositiveInteger (UPS-MIB) .1.3.6.1.4.1.850.100.1.4.7.1.1 |
tlUpsOutputCircuitStatusWhether the breaker is open or closed.ro Enumeration .1.3.6.1.4.1.850.100.1.4.7.1.2 |
tlUpsOutputCircuitLoadCurrentThe magnitude of the present output current in tenths of an amp. A value of 65534 indicates Unknown.ro NonNegativeInteger UNITS "0.1 Amperes" .1.3.6.1.4.1.850.100.1.4.7.1.3 |
tlUpsOutputCircuitVoltageThe magnitude of the present circuit voltage in tenths of an volt.ro NonNegativeInteger UNITS "0.1 Volts" .1.3.6.1.4.1.850.100.1.4.7.1.4 |
tlUpsOutputCircuitPowerThe magnitude of the present power in watts. tenths of an amp.ro NonNegativeInteger UNITS "Watts" .1.3.6.1.4.1.850.100.1.4.7.1.5 |
tlUpsOutputCircuitPowerFactorThe power factor of all receptacles in a given circuit as a %.ro NonNegativeInteger UNITS "Percent" .1.3.6.1.4.1.850.100.1.4.7.1.6 |
tlUpsAggregatePowerFactorThe aggregrate power factor of all phases.ro PositiveInteger UNITS "0.1 Watts" .1.3.6.1.4.1.850.100.1.4.8 |
tlUpsAlarm OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6 |
tlUpsAlarmsPresentThe present number of active alarm conditions.ro Gauge32 .1.3.6.1.4.1.850.100.1.6.1 |
tlUpsAlarmTableA list of alarm table entries. SEQUENCE OF TlUpsAlarmEntry .1.3.6.1.4.1.850.100.1.6.2 |
tlUpsAlarmEntryAn entry containing information applicable to a particular alarm. TlUpsAlarmEntry .1.3.6.1.4.1.850.100.1.6.2.1 |
tlUpsAlarmIdA unique identifier for an alarm condition.ro PositiveInteger (UPS-MIB) .1.3.6.1.4.1.850.100.1.6.2.1.1 |
tlUpsAlarmDescrA description of the alarm condition.ro AutonomousType (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.6.2.1.2 |
tlUpsAlarmTimeThe value of sysUpTime when the alarm condition was detected.ro TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.6.2.1.3 |
tlUpsAlarmDetailA textual description of the alarm condition.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.6.2.1.4 |
tlUpsAlarmDeviceIdA numeric identifier for the device on which the alarm is active.ro PositiveInteger (UPS-MIB) .1.3.6.1.4.1.850.100.1.6.2.1.5 |
tlUpsAlarmDeviceNameA string identifier for the device on which the alarm is active.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.6.2.1.6 |
tlUpsAlarmLocationThe location of the device on which the alarm is active.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.6.2.1.7 |
tlUpsAlarmGroupThe category/group of this alarm.ro Enumeration .1.3.6.1.4.1.850.100.1.6.2.1.8 |
tlUpsAlarmIpThe originating IP address associated with this alarm.ro IpAddress .1.3.6.1.4.1.850.100.1.6.2.1.9 |
tlUpsAlarmMacThe originating mac address associated with this alarm.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.6.2.1.10 |
tlUpsWellKnownAlarms OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3 |
tlUpsAlarmPrimaryPowerOutageThe primary power source is not present. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.1 |
tlUpsAlarmSecondaryPowerOutageThe secondary power source is not present. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.2 |
tlUpsAlarmLoadLevelAboveThresholdThe load level is above the designated threshold. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.3 |
tlUpsAlarmOutputCurrentChangedThe output current changed from its last known value. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.4 |
tlUpsAlarmBatteryAgeAboveThresholdOne or more batteries have been determined to require replacement. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.5 |
tlUpsAlarmLoadOffThe load is off. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.6 |
tlUpsAlarmUserDefinedA user-defined event is in alarm. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.7 |
tlUpsAlarmBatteryBadOne or more batteries have been determined to require replacement. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.8 |
tlUpsAlarmOnBatteryThe UPS is drawing power from the batteries. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.9 |
tlUpsAlarmLowBatteryThe remaining battery run-time is less than or equal to upsConfigLowBattTime. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.10 |
tlUpsAlarmDepletedBatteryThe UPS will be unable to sustain the present load when and if the utility power is lost. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.11 |
tlUpsAlarmTempBadA temperature is out of tolerance. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.12 |
tlUpsAlarmInputBadAn input condition is out of tolerance. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.13 |
tlUpsAlarmOutputBadAn output condition (other than OutputOverload) is out of tolerance. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.14 |
tlUpsAlarmOutputOverloadThe output load exceeds the UPS output capacity. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.15 |
tlUpsAlarmOnBypassThe Bypass is presently engaged on the UPS. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.16 |
tlUpsAlarmBypassBadThe Bypass is out of tolerance. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.17 |
tlUpsAlarmOutputOffAsRequestedThe UPS has shutdown as requested, i.e., the output is off. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.18 |
tlUpsAlarmUpsOffAsRequestedThe entire UPS has shutdown as commanded. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.19 |
tlUpsAlarmChargerFailedAn uncorrected problem has been detected within the UPS charger subsystem. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.20 |
tlUpsAlarmUpsOutputOffThe output of the UPS is in the off state. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.21 |
tlUpsAlarmUpsSystemOffThe UPS system is in the off state. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.22 |
tlUpsAlarmFanFailureThe failure of one or more fans in the UPS has been detected. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.23 |
tlUpsAlarmFuseFailureThe failure of one or more fuses has been detected. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.24 |
tlUpsAlarmGeneralFaultA general fault in the UPS has been detected. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.25 |
tlUpsAlarmDiagnosticTestFailedThe result of the last diagnostic test indicates a failure. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.26 |
tlUpsAlarmCommunicationsLostA problem has been encountered in the communications between the agent and the UPS. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.27 |
tlUpsAlarmAwaitingPowerThe UPS output is off and the UPS is awaiting the return of input power. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.28 |
tlUpsAlarmShutdownPendingA upsShutdownAfterDelay countdown is underway. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.29 |
tlUpsAlarmShutdownImminentThe UPS will turn off power to the load in less than 5 seconds; this may be either a timed shutdown or a low battery shutdown. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.30 |
tlUpsAlarmTestInProgressA test is in progress, as initiated and indicated by the Test Group. Tests initiated via other implementation-specific mechanisms can indicate the presence of the testing in the alarm table, if desired, via a OBJECT-IDENTITY macro in the MIB document specific to that implementation and are outside the scope of this OBJECT-IDENTITY. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.31 |
tlUpsAlarmCircuitBreaker1OpenCircuit breakers #1 is open. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.32 |
tlUpsAlarmCircuitBreaker2OpenCircuit breakers #2 is open. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.33 |
tlUpsAlarmCircuitBreaker3OpenCircuit breakers #3 is open. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.34 |
tlUpsAlarmCircuitBreaker4OpenCircuit breakers #4 is open. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.35 |
tlUpsAlarmCircuitBreaker5OpenCircuit breakers #5 is open. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.36 |
tlUpsAlarmCircuitBreaker6OpenCircuit breakers #6 is open. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.37 |
tlUpsAlarmCircuitBreaker7OpenCircuit breakers #7 is open. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.38 |
tlUpsAlarmCircuitBreaker8OpenCircuit breakers #8 is open. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.39 |
tlUpsAlarmCurrent1AboveThresholdThe output current on line 1 exceeds load limits. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.40 |
tlUpsAlarmCurrent2AboveThresholdThe output current on line 2 exceeds load limits. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.41 |
tlUpsAlarmCurrent3AboveThresholdThe output current on line 3 exceeds load limits. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.42 |
tlUpsAlarmRuntimeBelowWarningLevelThe battery seconds remaining is below warning level. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.43 |
tlUpsAlarmBusStartVoltageLowThe inverter start up bus voltage is too low. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.44 |
tlUpsAlarmBusOverVoltageThe inverter bus voltage is too high. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.45 |
tlUpsAlarmBusUnderVoltageThe inverter bus voltage is too low. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.46 |
tlUpsAlarmBusVoltageUnbalancedThe inverter bus voltage is not balanced. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.47 |
tlUpsAlarmInverterSoftStartBadThe inverter bus voltage cannot reach desired voltage within a specified duration. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.48 |
tlUpsAlarmInverterOverVoltageThe inverter voltage is too high. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.49 |
tlUpsAlarmInverterUnderVoltageThe inverter voltage is too low. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.50 |
tlUpsAlarmInverterCircuitBadThe inverter output is shorted. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.51 |
tlUpsAlarmBatteryOverVoltageThe battery voltage is too high. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.52 |
tlUpsAlarmBatteryUnderVoltageThe battery voltage is too low. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.53 |
tlUpsAlarmSiteWiringFaultThe utility input wiring is faulty. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.54 |
tlUpsAlarmOverTemperatureProtectionThe over temperature protection is activated. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.55 |
tlUpsAlarmOverChargedThe UPS is over charged. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.56 |
tlUpsAlarmEPOActiveThe EPO is currently activate. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.57 |
tlUpsAlarmBypassFrequencyBadThe bypass frequency is out of tolerance. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.58 |
tlUpsAlarmExternalSmartBatteryAgeAboveThresholdOne or more external smart batteries have been determined to require replacement. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.59 |
tlUpsAlarmExternalNonSmartBatteryAgeAboveThresholdOne or more external non-smart batteries have been determined to require replacement. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.60 |
tlUpsAlarmSmartBatteryCommLostCommunications with the smart batteries was lost. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.61 |
tlUpsAlarmSourceAOutageInput power source A is not present. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.62 |
tlUpsAlarmSourceBOutageInput power source B is not present. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.63 |
tlUpsAlarmWatchdogResetThe internal watchdog triggered a reset of the device. OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.6.3.64 |
tlUpsAlarmDevNameThe name of the device, tlDevName, corresponding to the device that is associated with this alarm.rodeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.6.7 |
tlUpsAlarmDevLocationThe location of the device, tlDevLocation, corresponding to the device that is associated with this alarm.rodeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.6.8 |
tlUpsAlarmCategoryThe category, tlDevEvtCategory, of this alarm.rodeprecated Integer32 .1.3.6.1.4.1.850.100.1.6.9 |
tlUpsTest OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.7 |
tlUpsTestDateThe date of the last self-test run on the ups, in the format YYYYMMDD.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.7.1 |
tlUpsTestResultsDetailResult of the last self-test run on the ups.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.7.2 |
tlUpsControl OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.8 |
tlUpsWatchdogSupportedIndicates whether or not this UPS supports a watchdog reboot.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.8.1 |
tlUpsWatchdogSecsBeforeRebootThe maximum number of seconds that can expire between polls that the engine makes to the UPS for data. If this time runs out, then the UPS will cycle its outputs. Set this to zero to turns disable this feature.rw NonNegativeInteger (UPS-MIB) .1.3.6.1.4.1.850.100.1.8.2 |
tlUpsWellKnownControls OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.8.3 |
tlUpsControlSelfTestSet to TRUE to initiate Self Testrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.8.3.1 |
tlUpsControlRampSet to TRUE to initiate Ramprw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.8.3.2 |
tlUpsControlShedSet to TRUE to initiate Shedrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.8.3.3 |
tlUpsControlUpsOnSet to TRUE to turn UPS onrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.8.3.4 |
tlUpsControlUpsOffSet to TRUE to turn UPS offrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.8.3.5 |
tlUpsConfig OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.9 |
tlUpsConfigBattReplDateThe date on which the battery was last replaced, in the format YYYYMMDD.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.9.1 |
tlUpsConfigDisplayUnitsSelects English or Metric display for all readings. This selection may not be available on all devices. Further, some devices may support this selection, but not via a software selector. In this latter case, selections must be performed on the device itself.rw Enumeration .1.3.6.1.4.1.850.100.1.9.4 |
tlUpsConfigExternalBattReplDateThe date on which the external battery was last replaced, in the format YYYYMMDD.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.9.5 |
tlUpsOutlet OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.10 |
tlUpsOutletNumOutletsThe number of available Outlets in this device.ro NonNegativeInteger (UPS-MIB) .1.3.6.1.4.1.850.100.1.10.1 |
tlUpsOutletTableA list of all device Outlets for all devices. SEQUENCE OF TlUpsOutletEntry .1.3.6.1.4.1.850.100.1.10.2 |
tlUpsOutletEntryAn entry containing Outlet information applicable to a particular device managed by this agent. TlUpsOutletEntry .1.3.6.1.4.1.850.100.1.10.2.1 |
tlUpsOutletIndexThis is the index number of this Outlet for the device indicated by tlDeviceIndex.ro PositiveInteger (UPS-MIB) .1.3.6.1.4.1.850.100.1.10.2.1.1 |
tlUpsOutletStateThe current state of the Outlet.ro Enumeration .1.3.6.1.4.1.850.100.1.10.2.1.2 |
tlUpsOutletTypeThis is a bit field that indicates the type of this Outlet. When 0, the outlet is not controllable and has none of the other features indicated in the bit map. When non-zero, the features present for this outlet can be interpreted with the definition. Bit Display 0 Reserved, may be 1 or 0 1 Controllable 2 3 4 5 6 7 8 9 10 11 12 13 14 15ro Integer32 .1.3.6.1.4.1.850.100.1.10.2.1.3 |
tlUpsOutletControlControls the state of the Outlet.rw Enumeration .1.3.6.1.4.1.850.100.1.10.2.1.4 |
tlUpsOutletNameA string identifying the devices attached to the output(s) of the device.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.10.2.1.5 |
tlUpsOutletRampActionThe ramp action to take on the Outlet.rw Enumeration .1.3.6.1.4.1.850.100.1.10.2.1.6 |
tlUpsOutletRampDataTypeThe type of data associated with ramp action.rw Enumeration .1.3.6.1.4.1.850.100.1.10.2.1.7 |
tlUpsOutletRampDataThe data value associated with type of ramp data.rw Integer32 .1.3.6.1.4.1.850.100.1.10.2.1.8 |
tlUpsOutletShedActionThe shed action to take on the Outlet.rw Enumeration .1.3.6.1.4.1.850.100.1.10.2.1.9 |
tlUpsOutletShedDataTypeThe type of data associated with shed action.rw Enumeration .1.3.6.1.4.1.850.100.1.10.2.1.10 |
tlUpsOutletShedDataThe data value associated with type of shed data.rw Integer32 .1.3.6.1.4.1.850.100.1.10.2.1.11 |
tlUpsOutletGroupNdxtlUpsOutletGroupIndex of corresponding outlet group, or 0 if ungrouped.rw Integer32 .1.3.6.1.4.1.850.100.1.10.2.1.12 |
tlUpsOutletCurrentThe value of this outlet's current, represented as 0.1A.ro PositiveInteger UNITS "0.1 RMS Amp" .1.3.6.1.4.1.850.100.1.10.2.1.13 |
tlUpsOutletPowerThe value of this outlet's power in watts.ro PositiveInteger (UPS-MIB) .1.3.6.1.4.1.850.100.1.10.2.1.14 |
tlUpsOutletGroup OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.11 |
tlUpsOutletNumOutletGroupsThe number of available Outlet Groups in this device.ro NonNegativeInteger (UPS-MIB) .1.3.6.1.4.1.850.100.1.11.1 |
tlUpsOutletGroupTableA list of device outlet group entries. The number of entries is given by the value of tlUpsOutletNumOutletGroups. SEQUENCE OF TlUpsOutletGroupEntry .1.3.6.1.4.1.850.100.1.11.2 |
tlUpsOutletGroupEntryAn entry containing outlet group information applicable to a particular device managed by this agent TlUpsOutletGroupEntry .1.3.6.1.4.1.850.100.1.11.2.1 |
tlUpsOutletGroupIndexThis is the index number of this load group for the device.ro PositiveInteger (UPS-MIB) .1.3.6.1.4.1.850.100.1.11.2.1.1 |
tlUpsOutletGroupRowStatusRow status for the tlUpsOutletGroupTablerw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.11.2.1.2 |
tlUpsOutletGroupNameThe name of this outlet group.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.11.2.1.3 |
tlUpsOutletGroupDescA description for this outlet group.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.11.2.1.4 |
tlUpsOutletGroupStateThe current state of the outlet group.ro Enumeration .1.3.6.1.4.1.850.100.1.11.2.1.5 |
tlUpsOutletGroupControlControls the state of every outlet associated with the group.rw Enumeration .1.3.6.1.4.1.850.100.1.11.2.1.6 |
tlUpsMainOutlet OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.12 |
tlUpsMainOutletStateThe current state of the main output of the device.ro Enumeration .1.3.6.1.4.1.850.100.1.12.1 |
tlUpsMainOutletControllableIndicates if this device has controllable outletsro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.850.100.1.12.2 |
tlUpsMainOutletControlControls the state of the main outlet of the device.rw Enumeration .1.3.6.1.4.1.850.100.1.12.3 |
tlUpsEnvironment OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.1.13 |
tlUpsTemperatureThe ambient temperature. The measurement returned will either be in units of Celsius (C) or Fahrenheit (F) depending upon whether Metric or English was selected for the reading by tlUpsConfigDisplayUnits.ro Integer32 .1.3.6.1.4.1.850.100.1.13.1 |
tlUpsTraps OBJECT IDENTIFIER .1.3.6.1.4.1.850.100.2 |
tlUpsTrapAlarmEntryAddedV1This trap is sent each time an alarm is inserted into to the alarm table. NOTIFICATION-TYPE .1.3.6.1.4.1.850.100.2.0.3 |
tlUpsTrapAlarmEntryRemovedV1This trap is sent each time an alarm is removed from the alarm table. NOTIFICATION-TYPE .1.3.6.1.4.1.850.100.2.0.4 |
tlUpsTrapAlarmEntryAddedThis trap is sent each time an alarm is inserted into to the alarm table. NOTIFICATION-TYPE .1.3.6.1.4.1.850.100.2.3 |
tlUpsTrapAlarmEntryRemovedThis trap is sent each time an alarm is removed from the alarm table. NOTIFICATION-TYPE .1.3.6.1.4.1.850.100.2.4 |
tlUpsTrapSystemStartupUsed to inform another entity of an engine's startup. The varbinds that follow are: OBJ1 = tlEngineType Obj1Value = The type of engine providing this data OBJ2 = tlEngineSoftwareVersion Obj2Value = The current version of the engine OBJ3 = tlEngineMACAddr Obj3Value = The MAC address of the engine OBJ4 = tlUpsSnmpCardSerialNum Obj4Value = The serial number of the SNMPWEBCARD [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlDevManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlDevModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlDevName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlDevLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlDevRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlDevProtocol, indexed by device Obj11Value= The device's protocol (display string format) NOTIFICATION-TYPE .1.3.6.1.4.1.850.100.2.5 |
tlUpsTrapSystemShutdownUsed to inform another entity of an engine's startup. The varbinds that follow are: OBJ1 = tlEngineType Obj1Value = The type of engine providing this data OBJ2 = tlEngineSoftwareVersion Obj2Value = The current version of the engine OBJ3 = tlEngineMACAddr Obj3Value = The MAC address of the engine OBJ4 = tlUpsSnmpCardSerialNum Obj4Value = The serial number of the SNMPWEBCARD [should be 0 on PC] --- if this trap is extended, place all static OIDs above this mark. all objects below --- the number of devices (tlNumDevices) is explicit as per device for enumeration by --- the target receiver OBJ5 = tlNumDevices Obj5Value = The number of devices attached --- The following objects will be replicated per each device: OBJ6 = The OID for an entry of tlDevManufacturer, indexed by device Obj6Value = The device's manufacturer OBJ7 = The OID for an entry of tlDevModel, indexed by device Obj7Value = The device's model name OBJ8 = The OID for an entry of tlDevName, indexed by device Obj8Value = The device's display name OBJ9 = The OID for an entry of tlDevLocation, indexed by device Obj9Value = The device's location OBJ10 = The OID for an entry of tlDevRegion, indexed by device Obj10Value= The device's region OBJ11 = The OID for an entry of tlDevProtocol, indexed by device Obj11Value= The device's protocol (display string format) NOTIFICATION-TYPE .1.3.6.1.4.1.850.100.2.6 |
tlEnviroSense OBJECT IDENTIFIER .1.3.6.1.4.1.850.101 |
tlEnvEnvironment OBJECT IDENTIFIER .1.3.6.1.4.1.850.101.1 |
tlEnvTemperatureData OBJECT IDENTIFIER .1.3.6.1.4.1.850.101.1.1 |
tlEnvTemperatureCThe ambient temperature (C).ro Integer32 .1.3.6.1.4.1.850.101.1.1.1 |
tlEnvTemperatureFThe ambient temperature (F).ro Integer32 .1.3.6.1.4.1.850.101.1.1.2 |
tlEnvTemperatureLowLimitThe lower alarm limit for ambient temperature (F).rw Integer32 .1.3.6.1.4.1.850.101.1.1.3 |
tlEnvTemperatureHighLimitThe upper alarm limit for ambient temperature (F).rw Integer32 .1.3.6.1.4.1.850.101.1.1.4 |
tlEnvTemperatureInAlarmIndicates whether or not temperature is in alarm.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.850.101.1.1.5 |
tlEnvHumidityData OBJECT IDENTIFIER .1.3.6.1.4.1.850.101.1.2 |
tlEnvHumidityThe ambient humidity (%).ro Integer32 .1.3.6.1.4.1.850.101.1.2.1 |
tlEnvHumidityLowLimitThe lower alarm limit for ambient humidity (%).rw Integer32 .1.3.6.1.4.1.850.101.1.2.2 |
tlEnvHumidityHighLimitThe upper alarm limit for ambient humidity (%).rw Integer32 .1.3.6.1.4.1.850.101.1.2.3 |
tlEnvHumidityInAlarmIndicates whether or not humidity is in alarm.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.850.101.1.2.4 |
tlEnvContacts OBJECT IDENTIFIER .1.3.6.1.4.1.850.101.2 |
tlEnvContactTableA table of contacts. SEQUENCE OF TlEnvContactEntry .1.3.6.1.4.1.850.101.2.1 |
tlEnvContactEntryAn entry containing information applicable to a particular contact. TlEnvContactEntry .1.3.6.1.4.1.850.101.2.1.1 |
tlEnvContactIndexThe table row index for the contact.ro PositiveInteger (UPS-MIB) .1.3.6.1.4.1.850.101.2.1.1.1 |
tlEnvContactNameThe name or description of the contact.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.101.2.1.1.2 |
tlEnvContactStatusThe current status of the contact.ro Enumeration .1.3.6.1.4.1.850.101.2.1.1.3 |
tlEnvContactConfigThe configuration of the contact.rw Enumeration .1.3.6.1.4.1.850.101.2.1.1.4 |
tlCooling OBJECT IDENTIFIER .1.3.6.1.4.1.850.103 |
tlCoolingEnvironment OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.1 |
tlCoolingIdent OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.1.1 |
tlCoolingModelThe model name for the AC Unit.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.103.1.1.1 |
tlCoolingManufacturerThe manufacturer of the AC Unit.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.103.1.1.2 |
tlCoolingSerialNumberThe serial number of the AC unit.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.103.1.1.3 |
tlCoolingFirmwareVersionThe firmware version of the AC Unit.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.103.1.1.4 |
tlCoolingHostSoftwareVersionThe hardware version of the AC unit.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.103.1.1.5 |
tlCoolingNameThe user defined name for the AC Unit.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.103.1.1.6 |
tlCoolingLocationThe user defined location of the AC Unit.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.103.1.1.7 |
tlCoolingStatus OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.1.2 |
tlCoolingCondOutletTempThe condenser outlet air stream temperature in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits.ro INTEGER .1.3.6.1.4.1.850.103.1.2.1 |
tlCoolingCondInletTempThe condenser inlet air stream temperature in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits.ro INTEGER .1.3.6.1.4.1.850.103.1.2.2 |
tlCoolingRefrigerantTempThe temperature of the refrigerant in the suction line. This is displayed in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits.ro INTEGER .1.3.6.1.4.1.850.103.1.2.3 |
tlCoolingEvapSurfaceTempThe surface temperature of the evaporator in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits.ro INTEGER .1.3.6.1.4.1.850.103.1.2.4 |
tlCoolingSuctionPressureThe pressure of the compressor suction line in tenths of (Mpa/psi) depending on the value of tlCoolingDisplayUnits.ro INTEGER .1.3.6.1.4.1.850.103.1.2.5 |
tlCoolingDischargePressureThe pressure of the compressor discharge line in tenths of (Mpa/psi) depending on the value of tlCoolingDisplayUnits.ro INTEGER .1.3.6.1.4.1.850.103.1.2.6 |
tlCoolingEvapFanSpeedThe current speed of the evaporator fan.ro Enumeration .1.3.6.1.4.1.850.103.1.2.7 |
tlCoolingCondFanSpeedThe current speed of the condenser fan.ro Enumeration .1.3.6.1.4.1.850.103.1.2.8 |
tlCoolingCompFrequencyThe operating frequency of the compressor in tenths of Arms.ro INTEGER .1.3.6.1.4.1.850.103.1.2.9 |
tlCoolingEEVPercentageThe opening percentage of the EEV.ro INTEGER .1.3.6.1.4.1.850.103.1.2.10 |
tlCoolingUnitCurrentThe the total current draw of the unit in tenths of Arms.ro INTEGER .1.3.6.1.4.1.850.103.1.2.11 |
tlCoolingFanCurrentThethe current draw of the Evaporator and Condenser fans in tents of Arms.ro INTEGER .1.3.6.1.4.1.850.103.1.2.12 |
tlCoolingCompCurrentThe operating current of the compressor in Arms.ro INTEGER .1.3.6.1.4.1.850.103.1.2.13 |
tlCoolingReturnAirTempThe return air temperature in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits.ro INTEGER .1.3.6.1.4.1.850.103.1.2.14 |
tlCoolingSuctionTempThe temperature of the compressor suction line in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits.ro INTEGER .1.3.6.1.4.1.850.103.1.2.15 |
tlCoolingSupplyAirTempThe supply air temperature in tenths of degrees in the units Celcius/Fahrenheit as specified in tlCoolingDisplayUnits.ro INTEGER .1.3.6.1.4.1.850.103.1.2.16 |
tlCoolingRunTimes OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.1.3 |
tlCoolingAirFilterRunHoursTotal hours the air filter has been under operation.ro Integer32 .1.3.6.1.4.1.850.103.1.3.1 |
tlCoolingEvapFanRunDaysTotal days the evaporator fan has been under operation.ro Integer32 .1.3.6.1.4.1.850.103.1.3.2 |
tlCoolingCondFanRunDaysTotal days the condenser fan has been under operation.ro Integer32 .1.3.6.1.4.1.850.103.1.3.3 |
tlCoolingCompressorRunDaysTotal days the compressor has been under operation.ro Integer32 .1.3.6.1.4.1.850.103.1.3.4 |
tlCoolingCondPumpRunDaysTotal days the condensate pump has been under operation.ro Integer32 .1.3.6.1.4.1.850.103.1.3.5 |
tlCoolingAtomizerRunDaysTotal days the atomizer has been under operation.ro Integer32 .1.3.6.1.4.1.850.103.1.3.6 |
tlCoolingConfig OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.1.4 |
tlCoolingOnOffTurn the unit off or on.rw Enumeration .1.3.6.1.4.1.850.103.1.4.1 |
tlCoolingSetPointTempThe set point temperature the unit will control the temperature to in tenths of degrees in Celcius or Fahrenheit based upon tleCoolDisplayUnits.rw INTEGER .1.3.6.1.4.1.850.103.1.4.2 |
tlCoolingAutoStartSpecified if the unit should start automatically on power up.rw Enumeration .1.3.6.1.4.1.850.103.1.4.3 |
tlCoolingFanSpeedOverrideSpeed of evaporator fan set by the user.rw Enumeration .1.3.6.1.4.1.850.103.1.4.4 |
tlCoolingControlTypeWhich temperature to be used as a control point.rw Enumeration .1.3.6.1.4.1.850.103.1.4.5 |
tlCoolingCurrentRemoteTempThe external remote temperature in tenths of degrees in Celcius or Fahrenheit depending upon value of tlCoolingDisplayUnitsrw INTEGER .1.3.6.1.4.1.850.103.1.4.6 |
tlCoolingDisplayUnitsSelects English or Metric display for all readings.rw Enumeration .1.3.6.1.4.1.850.103.1.4.7 |
tlCoolingBeepOnKeyIndicates if the display sounds a beep when a key is pressed.rw Enumeration .1.3.6.1.4.1.850.103.1.4.8 |
tlCoolingOutputRelaySourceThe alarm level that causes the ouput relay to activate.rw Enumeration .1.3.6.1.4.1.850.103.1.4.9 |
tlCoolingOffOnLeakIndicates if the unit should stop cooling when leak input is activated.rw Enumeration .1.3.6.1.4.1.850.103.1.4.10 |
tlCoolingOffOnInputContactIndicates if the unit should stop cooling when input contact is activated.rw Enumeration .1.3.6.1.4.1.850.103.1.4.11 |
tlCoolingInputContactTypeThe input contact type.rw Enumeration .1.3.6.1.4.1.850.103.1.4.12 |
tlCoolingOutputRelayDefaultType of contact to make when output relay is activated.rw Enumeration .1.3.6.1.4.1.850.103.1.4.13 |
tlCoolingAirFilterIntervalThe number of weeks before the air filter needs to be changed.rw Integer32 .1.3.6.1.4.1.850.103.1.4.14 |
tlCoolingWaterLeakContactTypeThe input contact type.rw Enumeration .1.3.6.1.4.1.850.103.1.4.15 |
tlCoolingThresholds OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.1.5 |
tlCoolingMaxAirFilterRunHoursThe maximum interval for air filter run hours before warning is annunciated.rw Integer32 .1.3.6.1.4.1.850.103.1.5.1 |
tlCoolingEnableAirFilterAlarmWhen enabled indicated that an alarm should occur when the maximum number of air filter run hours has been exceeded.rw Enumeration .1.3.6.1.4.1.850.103.1.5.2 |
tlCoolingMaxSupplyTempMaximum allowed supply air temperature before firing an alarm.rw INTEGER .1.3.6.1.4.1.850.103.1.5.3 |
tlCoolingMinSupplyTempMinimum allowed supply air temperature allowed before firing an alarm.rw INTEGER .1.3.6.1.4.1.850.103.1.5.4 |
tlCoolingTempDiffAlarmMaximum allowed air temperature deviation from set allowed before firing an alarm.rw INTEGER .1.3.6.1.4.1.850.103.1.5.5 |
tlCoolingMaxReturnAirTempWhen enabled indicated that an alarm should occur when the maximum number of air filter run hours has been exceeded.rw INTEGER .1.3.6.1.4.1.850.103.1.5.6 |
tlCoolingAlarm OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6 |
tlCoolingWellKnownAlarms OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3 |
tlCoolingSupplyAirSensorFaultThe supply air sensor is in fault. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.1 |
tlCoolingReturnAirSensorFaultThe return air sensor is in fault. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.2 |
tlCoolingCondenserInletAirSensorFaultThe condenser inlet air sensor is in fault. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.3 |
tlCoolingCondenserOutletAirSensorFaultThe condenser outlet air sensor is in fault. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.4 |
tlCoolingSuctionTemperatureSensorFaultThe suction temperature sensor is in fault. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.5 |
tlCoolingEvaporatorTemperatureSensorFaultThe evaporator temperature sensor is in fault. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.6 |
tlCoolingAirFilterCloggedThe air filter is clogged. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.7 |
tlCoolingAirFilterRunHoursViolationThe air filter run hours was violated. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.8 |
tlCoolingSuctionPressureSensorFaultThe suction pressure sensor is in fault. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.9 |
tlCoolingInverterCommunicationsFaultThe inverter communications is in fault. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.10 |
tlCoolingRemoteShutdownViaInputContactA remote shutdown was triggerd by an input contact. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.11 |
tlCoolingCondensatePumpFaultThe condensate pump is in fault. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.12 |
tlCoolingLowRefrigerantStartupFaultThe low refrigerant startup is in fault. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.13 |
tlCoolingCondenserFanFaultThe condenser fan is in fault. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.14 |
tlCoolingCondenserFailureThe condenser has failed. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.15 |
tlCoolingEvaporatorCoolingFailureThe evaporator cooling is in fault. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.16 |
tlCoolingReturnAirTempHighThe return air temperature is high. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.17 |
tlCoolingSupplyAirTempHighThe supply air temperature is high. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.18 |
tlCoolingEvaporatorFailureThe evaporator has failed. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.19 |
tlCoolingEvaporatorFreezeUpThe evaporator is frozen. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.20 |
tlCoolingDischargePressureHighThe discharge pressure is high. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.21 |
tlCoolingPressureGaugeFailureThe pressure gauge has failed. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.22 |
tlCoolingDischargePressurePersistentHighThe discharge pressure is persistently high. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.23 |
tlCoolingSuctionPressureLowStartFailureCannot start due to low suction pressure. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.24 |
tlCoolingSuctionPressureLowThe suction pressure is low. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.25 |
tlCoolingSuctionPressurePersistentLowThe suction pressure is persistently low. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.26 |
tlCoolingStartupLinePressureImbalanceThe startup line pressure is in imbalance. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.27 |
tlCoolingCompressorFailureThe compressor has failed. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.28 |
tlCoolingCurrentLimitThe current is out of range. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.29 |
tlCoolingWaterLeakWater is leaking. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.30 |
tlCoolingFanUnderCurrentThe fan is under current. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.31 |
tlCoolingFanOverCurrentThe fan is over current. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.32 |
tlCoolingDischargePressureSensorFaultThe discharge pressure sensor is in fault. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.33 |
tlCoolingWaterFullWater is Full. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.34 |
tlCoolingAutoCoolingOnAutomatic cooling was activated to lower the temperature below the remote set point. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.35 |
tlCoolingPowerButtonPressedPower button was pressed on the front panel. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.36 |
tlCoolingDisconnectedFromDeviceThe device communications is disconnected. OBJECT IDENTIFIER .1.3.6.1.4.1.850.103.6.3.37 |
tlSrCoolNet OBJECT IDENTIFIER .1.3.6.1.4.1.850.104 |
tlSrCoolNetData OBJECT IDENTIFIER .1.3.6.1.4.1.850.104.1 |
tlSrCoolNetIdent OBJECT IDENTIFIER .1.3.6.1.4.1.850.104.1.1 |
tlSrCoolNetModelThe model name for the device attached to the SRCOOLNET.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.104.1.1.1 |
tlSrCoolNetManufacturerThe manufacturer of the AC Unit.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.104.1.1.2 |
tlSrCoolNetSerialNumberThe serial number of the SRCOOLNET device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.104.1.1.3 |
tlSrCoolNetHostSoftwareVersionThe software version of the SRCOOLNET device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.104.1.1.4 |
tlSrCoolNetNameThe user defined name for the AC Unit.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.104.1.1.5 |
tlSrCoolNetLocationThe user defined location of the AC Unit.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.850.104.1.1.6 |
tlSrCoolNetStatus OBJECT IDENTIFIER .1.3.6.1.4.1.850.104.1.2 |
tlSrCoolNetModeThe current mode of SRCOOLNET.ro Enumeration .1.3.6.1.4.1.850.104.1.2.1 |
tlSrCoolNetFanSpeedThe current speed of the fan.ro Enumeration .1.3.6.1.4.1.850.104.1.2.2 |
tlSrCoolNetReturnAirTempThe return air stream temperature in tenths of degrees in the units Celsius/Fahrenheit as specified in tlSrCoolNetDisplayUnits.ro INTEGER .1.3.6.1.4.1.850.104.1.2.3 |
tlSrCoolNetWaterFullIndicates the water reservoir is full or not full.ro Enumeration .1.3.6.1.4.1.850.104.1.2.4 |
tlSrCoolNetCurrentRemoteTempThe EnviroSense temperature in tenths of degrees in Celsius or Fahrenheit depending upon value of tlSrCoolNetDisplayUnits. Only available if EnviroSense is connected to SRCOOLNET.ro INTEGER .1.3.6.1.4.1.850.104.1.2.5 |
tlSrCoolNetDisplayUnitsSelects English or Metric display for all readings. AC unit must be manually configured to match this setting.ro Enumeration .1.3.6.1.4.1.850.104.1.2.6 |
tlSrCoolNetConfig OBJECT IDENTIFIER .1.3.6.1.4.1.850.104.1.3 |
tlSrCoolNetOnOffTurn the unit off or on.rw Enumeration .1.3.6.1.4.1.850.104.1.3.1 |
tlSrCoolSetModeSet the operating mode of cooling unit. Unit must be ON to set mode.rw Enumeration .1.3.6.1.4.1.850.104.1.3.2 |
tlSrCoolNetSetPointTempThe local set point temperature in tenths of degrees in Celsius or Fahrenheit based upon tlSrCoolNetDisplayUnits.rw INTEGER .1.3.6.1.4.1.850.104.1.3.3 |
tlSrCoolNetRemoteSetPointTempThe remote set point temperature in tenths of degrees in Celsius or Fahrenheit based upon tlSrCoolNetDisplayUnits. Only available when EnviroSense is connected to SRCOOLNET.rw INTEGER .1.3.6.1.4.1.850.104.1.3.4 |
tlSrCoolNetFanSpeedSettingSet the fan speed of the AC unit.rw Enumeration .1.3.6.1.4.1.850.104.1.3.5 |
tlSrCoolNetRemoteSetpointEnableUse remote temperature setpoint for control point versus return air temp. Only available when EnviroSense is connected to SRCOOLNET.rw Enumeration .1.3.6.1.4.1.850.104.1.3.6 |
tlSrCoolNetFanAlwaysOnLeave fans on when not cooling. Only available when EnviroSense is connected to SRCOOLNET.rw Enumeration .1.3.6.1.4.1.850.104.1.3.7 |
tlSrCoolNetAlarm OBJECT IDENTIFIER .1.3.6.1.4.1.850.104.2 |
tlSrCoolNetWellKnownAlarms OBJECT IDENTIFIER .1.3.6.1.4.1.850.104.2.1 |
tlSrCoolNetWaterFullAlarmWater reservoir full. OBJECT IDENTIFIER .1.3.6.1.4.1.850.104.2.1.1 |