The TIMETRA-ALARM-MIB extends the standard ALARM-MIB to provision and monitor critical alarm states, severity levels, and event logs on Alcatel-Lucent (now Nokia) SR OS (SROS) routers. It enables SNMP-based retrieval of device-specific fault conditions and alarm history for operational troubleshooting and network health verification.

This document, an extension of ALARM-MIB defined in RFC 3877, is the SNMP MIB module to manage and provision the alarm management components of the Alcatel-Lucent SROS device. Copyright (c) 2010-2011 Alcatel-Lucent. All rights reserved. Reproduction of this document is authorized on the condition that the foregoing copyright notice is included. This SNMP MIB module (Specification) embodies Alcatel-Lucent's proprietary intellectual property. Alcatel-Lucent retains all title and ownership in the Specification, including any revisions. Alcatel-Lucent grants all interested parties a non-exclusive license to use and distribute an unmodified copy of this Specification in connection with management of Alcatel-Lucent products, and without fee, provided this copyright notice and license appear on all copies. This Specification is supplied 'as is', and Alcatel-Lucent makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification.
Main OID:
timetraAlarmMIBModule.1.3.6.1.4.1.6527.1.1.3.77
12
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

12 total
Object Name
timetraAlarmMIBModuleThis document, an extension of ALARM-MIB defined in RFC 3877, is the SNMP MIB module to manage and provision the alarm management components of the Alcatel-Lucent SROS device. Copyright (c) 2010-2011 Alcatel-Lucent. All rights reserved. Reproduction of this document is authorized on the condition that the foregoing copyright notice is included. This SNMP MIB module (Specification) embodies Alcatel-Lucent's proprietary intellectual property. Alcatel-Lucent retains all title and ownership in the Specification, including any revisions. Alcatel-Lucent grants all interested parties a non-exclusive license to use and distribute an unmodified copy of this Specification in connection with management of Alcatel-Lucent products, and without fee, provided this copyright notice and license appear on all copies. This Specification is supplied 'as is', and Alcatel-Lucent makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification.
MODULE-IDENTITY
.1.3.6.1.4.1.6527.1.1.3.77
tmnxAlarmConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.1.77
tmnxAlarmCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.1.77.1
tmnxAlarmGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.1.77.2
tmnxAlarmV9v0Groups
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.1.77.2.1
tmnxAlarmObjs
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.2.77
tmnxAlarmConfigTimeStamps
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.2.77.1
tmnxAlarmConfigurations
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.2.77.2
tmnxAlarmSystemConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.2.77.2.1
tmnxAlarmAdminStateThe value of tmnxAlarmAdminState specifies whether or not alarm management is enabled on the system. As a result of setting tmnxAlarmAdminState to 'disabled(2)', all alarms present in MIB table ALARM-MIB::alarmActiveTable will be cleared, all rows in MIB table ALARM-MIB::alarmClearTable will be destroyed, and no new alarms will be raised.rw
TmnxEnabledDisabled (TIMETRA-TC-MIB)
.1.3.6.1.4.1.6527.3.1.2.77.2.1.1
tmnxAlarmNotifyPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.3.77
tmnxAlarmNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.6527.3.1.3.77.0