TELESTE-COMMON-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for TELESTE-COMMON-MIB.
122
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
122 total| Object Name |
|---|
element OBJECT IDENTIFIER .1.3.6.1.4.1.5003.9.10.3.1.1.1 |
IMPORTS Unknown .1.3.6.1.4.1.5003.9.10.3.1.1.1 |
elementInformation OBJECT IDENTIFIER .1.3.6.1.4.1.5003.9.10.3.1.1.1.1 |
elementNameThis is the logical name of the controlling module of
the network element. The name may or may not be the same
as the module's name in the moduleTable.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5003.9.10.3.1.1.1.1.1 |
elementStructureThis object tells whether the device is a single compact
device or a modular device.ro Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.1.1.2 |
elementConfigChangeCodeThis object is an indicator about changes in the network
element configuration. How the value is formed is device
dependent. It can be a counter, a checksum of the device
configuration parameters, a DateAndTime type variable or
even SysUptime, if no other information is available.
DateAndTime is the recommended value.
This object is intended to permit a management application
to maintain configuration (including moduleTable)
syncronization with the agent.ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.1.3 |
elementResetCountTotal number of software resets during the device's life time.ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.1.4 |
elementTotalUpTimeThe total uptime the device (software) has been running. Unit 1 day.ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.1.5 |
elementLatitudeDevice latitude coordinate. Unit 0.00001 degrees.rw INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.1.6 |
elementLongitudeDevice longitude coordinate. Unit 0.00001 degrees.rw INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.1.7 |
elementAltitudeDevice altitude coordinate. Unit 1 metre.rw INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.1.8 |
elementStatus OBJECT IDENTIFIER .1.3.6.1.4.1.5003.9.10.3.1.1.1.2 |
statusGeneralA number stating the general status of the element.
Values:
1 = Normal
2 = At least one Notification is active
3 = At least one Warning is active
4 = At least one Alarm is active
If the element has more than one state active, then
the state with the highest value is returned.ro Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.1.2.1 |
statusBusMasterA number stating the Bus Master status of the NE.
Values:
1 = The NE is a slave-only device
2 = The NE is configured as slave
3 = The NE is configured as master but is currently
slave because a stronger master is on the bus
4 = The NE is currently the bus masterro Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.1.2.2 |
statusLmtA number telling if the Local Management Terminal (LMT)
is connected to the element.
Values:
1 = The element does not have an LMT interface
2 = The element can not detect if an LMT is connected
3 = The element has not detected a connected LMT
4 = The element has detected a connected LMT
Note! Applies only to fysically point-to-point
connected LMT's to device, not via bus ot other
shared medias.ro Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.1.2.3 |
statusLidElement lid status:
1 = no lid (no lid sensor is available)
2 = lid is closed
3 = lid is openro Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.1.2.4 |
statusTemperatureElement temperature status:
1 = normal
2 = HIHI
3 = Hi
4 = Lo
5 = LOLOro Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.1.2.5 |
statusFanA common status object for all fans in the device.
fanNormal(1) = all fans operate normally
fanFailure(2) = at least one fan has a failurero Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.1.2.6 |
statusHardwareDevice hardware status:
hwNormal(1) = the hardware operates normally
hwFailure(2) = a hardware failure is detectedro Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.1.2.7 |
statusSoftwareDevice software status:
swNormal(1) = the software operates normally
swFailure(2) = a software failure is detected
swMissing(3) = the software or firmware is missing
sw(Initialising(4) = the software is initialisingro Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.1.2.8 |
statusSettingsStatus of device settings:
settingsStable(1) = settings are stable
settingsChanged(2) = settings have been (recently) changed
settingsNotAvailable(3) = settings status is not available
The value should stay in value 2 only a predefined time, e.g. 60 seconds or
the time it takes until the settings are written into non-volatile memory.ro Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.1.2.9 |
elementControl OBJECT IDENTIFIER .1.3.6.1.4.1.5003.9.10.3.1.1.1.3 |
controlResetElementOn write requests this object commands the module to
reset itself.
If softReset(3) or hardReset(2) can not be performed,
then BAD VALUE error is returned.
On read requests value noReset(1) is returned.rw Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.1.3.1 |
controlBusMasterAdminStateThis object tells whether the element is configured as
a bus master or not. Only relevant for bus master type
of elements. Others return no(2).rw Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.1.3.2 |
controlAlarmDetectionThis variable is used to disable or enable the element
alarm checking. When disabled(1), the element
will not check any alarms (or send traps).
Default value is enabled(2).
Note: This variable must be consistent with
commonAlarmDetectionControl in SCTE-HMS-COMMON-MIB, if
that is implemented.rw Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.1.3.3 |
controlMaxNumberTrapReceiversNumber of entries in the elementTrapReceiverTable.
At least one trap entry must be supported.ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.3.4 |
controlTrapReceiverTableA table of manager trap receiver addresses, ports and
communities. Total number of entries can not exceed
elementNumberTrapReceivers. An entry is deleted from this
table by setting its IP address to '0.0.0.0'.
Note: one of the community strings must match to
commonTrapCommunityString in SCTE-HMS-COMMON-MIB, if
that is implemented. SEQUENCE OF ControlTrapReceiverEntry .1.3.6.1.4.1.5003.9.10.3.1.1.1.3.5 |
controlTrapReceiverEntry ControlTrapReceiverEntry .1.3.6.1.4.1.5003.9.10.3.1.1.1.3.5.1 |
receiverEntryIdUnique table index. Makes possible to have several
ip-address of 0.0.0.0 entries so that no mechanism
for row manipulation of table is needed.ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.3.5.1.1 |
receiverAddressIp address of the manager receiving Traps.rw IpAddress .1.3.6.1.4.1.5003.9.10.3.1.1.1.3.5.1.2 |
receiverPortTrap UDP port number. Default port is the standard trap
port 162.rw INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.3.5.1.3 |
receiverCommunityCommunity string for the trap receiver.
The agent is allowed to limit the length of the string.
Minimum length of eight characters must be supported.
Note: one of the community strings must match to
commonTrapCommunityString in SCTE-HMS-COMMON-MIB, if
that is implemented.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5003.9.10.3.1.1.1.3.5.1.4 |
controlTrapSendingEnables/disables trap sending.
1 = traps enabled
2 = traps disabledrw Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.1.3.6 |
controlTrapIntervalThe minimum interval between traps.
- Unit 10 milliseconds
- Minimum value 0 (send as fast as possible)
- Maximum value 1000 (10 seconds)
- Default value is 100 (1 second)rw INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.3.7 |
controlTrapLifeTimeThe maximum time a trap stays in the trap queue waiting
for sending.
- Unit 1 second.
- Minimum value 10
- Maximum value 300
- Default value 60rw INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.3.8 |
controlAlarmOnDelayThe minimum time an object's alarm/warning condition must
exist before it is recorded as an alarm/warning. Common
to all alarms/warnings
- Unit 10 ms
- Minimum value 10 (100 ms)
- Maximum value 6000 (60 seconds)
- Default value 100 (1 second)rw INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.3.9 |
controlAlarmOffDelayThe minimum time an alarm/warning entry stays active after
the object has reached it's normal condition. Common to all
alarms/warnings.
- Unit 10 ms
- Minimum value 10 (100 ms)
- Maximum value 6000 (60 seconds)
- default value 100 (1 second)rw INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.3.10 |
controlTrapDelayThe time before a trap is sent after an alarm
is detected.
- Unit 10 ms
- Minimum value 10 (100 ms)
- Maximum value 6000 (60 seconds)
- Default value 500 (5 seconds)
This parameter can be used to control alarm storms e.g.
in an amplifier cascade by using a different value in
each amplifier.rw INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.3.11 |
elementProductKey OBJECT IDENTIFIER .1.3.6.1.4.1.5003.9.10.3.1.1.1.4 |
productKeyNumberOfKeysNumber of product keys supported by the device.ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.4.4 |
productKeyTable SEQUENCE OF ProductKeyEntry .1.3.6.1.4.1.5003.9.10.3.1.1.1.4.5 |
productKeyEntry ProductKeyEntry .1.3.6.1.4.1.5003.9.10.3.1.1.1.4.5.1 |
productKeyIndexProduct key index.ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.4.5.1.1 |
productKeyValueProduct key value.rw OCTET STRING .1.3.6.1.4.1.5003.9.10.3.1.1.1.4.5.1.2 |
productKeyMaskProduct key mask.ro OCTET STRING .1.3.6.1.4.1.5003.9.10.3.1.1.1.4.5.1.3 |
productKeyStatusProduct key status:
1(keyInvalid) = the key is invalid or missing
2(keyValid) = the key is validro Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.1.4.5.1.4 |
productKeyCipherCipher method supported by this key:
1(cipherOther) = other ciphering is used
2(cipherBlowFish) = BlowFish ciphering is used
3(cipherXXTEA) = XXTEA ciphering is usedro Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.1.4.5.1.5 |
productKeyNumberOfFeaturesNumber of features available with this key.ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.4.5.1.6 |
productKeyFeatureTable SEQUENCE OF ProductKeyFeatureEntry .1.3.6.1.4.1.5003.9.10.3.1.1.1.4.6 |
productKeyFeatureEntry ProductKeyFeatureEntry .1.3.6.1.4.1.5003.9.10.3.1.1.1.4.6.1 |
productKeyFeatureIndexFeature index (second index).ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.4.6.1.1 |
productKeyFeatureNameA human-readable description of the feature.ro OCTET STRING .1.3.6.1.4.1.5003.9.10.3.1.1.1.4.6.1.2 |
productKeyFeatureEnableStatus of the feature:
1(featureDisable) = the feature si disabled in this device
2(featureEnable) = the feature is enabled in this devicesro Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.1.4.6.1.3 |
productKeyFeatureExpirationTimeNumber of days left before the feature expires. A zero value means
infinite validity time. This object has a meaning only if the
feature is enabled (productKeyFeatureEnable = 2(featureEnable)).ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.1.4.6.1.4 |
module OBJECT IDENTIFIER .1.3.6.1.4.1.5003.9.10.3.1.1.2 |
moduleInformation OBJECT IDENTIFIER .1.3.6.1.4.1.5003.9.10.3.1.1.2.1 |
moduleTableThis table lists basic module identification and
configuration data of modules installed inside
the managed element.
The first row in the table list information about the
element itself. If the element is not modular, only the
first row exists in the table.
Object moduleId is used for indexing the modules
in all module section tables. SEQUENCE OF ModuleEntry .1.3.6.1.4.1.5003.9.10.3.1.1.2.1.1 |
moduleEntry ModuleEntry .1.3.6.1.4.1.5003.9.10.3.1.1.2.1.1.1 |
moduleIdAn unique module index identifying the (physical) modules
inside the network element. The exact conjunction between
the index and the physical modules depends on the element
structural principle.
For network elements containing plug-in modules the index
should follow module slot numbering.
This index should be used in all subsequent module tables.ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.2.1.1.1.1 |
moduleNameThe identification name ('aliasname') of the module.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5003.9.10.3.1.1.2.1.1.1.2 |
moduleHwTypeThe hardware type name of the module.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5003.9.10.3.1.1.2.1.1.1.3 |
moduleRackNoRack number of the module.
This can be used to identify the physical position of
the module in the case where the agent manages modules
that are in several racks.rw INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.2.1.1.1.4 |
moduleSlotNoSlot number of the module (within rack).rw INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.2.1.1.1.5 |
moduleDetailTableThis table lists detailed module data of modules installed
inside the element.
The first row in the table list information about the
element itself. If the element is not modular, only the
first row exists in the table. SEQUENCE OF ModuleDetailEntry .1.3.6.1.4.1.5003.9.10.3.1.1.2.1.2 |
moduleDetailEntry ModuleDetailEntry .1.3.6.1.4.1.5003.9.10.3.1.1.2.1.2.1 |
moduleMacAddressModule MAC address. If the MAC address is unknown
'00.00.00.00.00.00' is returned.ro TPhysAddress .1.3.6.1.4.1.5003.9.10.3.1.1.2.1.2.1.1 |
moduleBusAddressModule bus address.ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.2.1.2.1.2 |
moduleAppDateModule application software date.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.5003.9.10.3.1.1.2.1.2.1.3 |
moduleAppVersionModule application software version. If software version
is undefined, then zero length string is returned.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5003.9.10.3.1.1.2.1.2.1.4 |
moduleBiosDateModule BIOS date.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.5003.9.10.3.1.1.2.1.2.1.5 |
moduleBiosVersionModule BIOS version. If bios version is undefined,
a zero length string is returned.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5003.9.10.3.1.1.2.1.2.1.6 |
moduleHwSerialNumberModule serial number.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5003.9.10.3.1.1.2.1.2.1.7 |
moduleHwVersionModule hardware version.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5003.9.10.3.1.1.2.1.2.1.8 |
moduleStatus OBJECT IDENTIFIER .1.3.6.1.4.1.5003.9.10.3.1.1.2.2 |
moduleStatusTableThis table contains status objects for modules inside
the network element.The first row in the table lists
information about the host module. If the element is
not modular, only the first row exists in the table. SEQUENCE OF ModuleStatusEntry .1.3.6.1.4.1.5003.9.10.3.1.1.2.2.1 |
moduleStatusEntryRow in moduleStatusTable. The index is moduleId from
the moduleTable. Row in this table exist only if
there is a row with the same moduleId in the moduleTable. ModuleStatusEntry .1.3.6.1.4.1.5003.9.10.3.1.1.2.2.1.1 |
statusResetCauseReason for the last reset.
If the reason is unknown, the value is reasonUnknown(1).
If the device makes self reset and it can detect it, then
value is reasonSelfReset(2). If the reset was made by the
user from the power switch and it can be sensed, then the
value is reasonPowerReset(3). If the reason is an external
command from the user interface or from the network
message (e.g. commonReset), then the reason is
reasonCommandedReset(4).ro Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.2.2.1.1.1 |
statusRunningSwImageCurrently running software image number.
Bios is 0, applications are numbered from 1..n,
where n is the maximum image number.ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.2.2.1.1.2 |
statusInternalTemperatureDevice temperature, unit 0.1 deg C. Value is zero (0),
if temperature is not available.ro INTEGER (-600..1300) .1.3.6.1.4.1.5003.9.10.3.1.1.2.2.1.1.3 |
statusLidStatusCurrent lid status detected by the device. May or may not be
the same variable as the elementLidStatus.ro Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.2.2.1.1.4 |
statusRestartCounterThis objects counts the number of restarts of the module.
A start can be a cold start or a warm start.ro Counter .1.3.6.1.4.1.5003.9.10.3.1.1.2.2.1.1.5 |
moduleControl OBJECT IDENTIFIER .1.3.6.1.4.1.5003.9.10.3.1.1.2.3 |
moduleControlTableThis table contains common control commands for all the
modules inside the element. SEQUENCE OF ModuleControlEntry .1.3.6.1.4.1.5003.9.10.3.1.1.2.3.1 |
moduleControlEntry ModuleControlEntry .1.3.6.1.4.1.5003.9.10.3.1.1.2.3.1.1 |
controlLedUsageA variable to instruct how device LED's behave when
the lid is closed.rw Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.2.3.1.1.1 |
controlMarkStateA variable to instruct the device to start and stop
showing mark (blinking module LED).
On read requests returns the current mark state.rw Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.2.3.1.1.2 |
controlResetOn write requests this object commands the module to
reset itself.
If softReset(3) or hardReset(2) can not be performed,
then BAD VALUE error is returned.
On read requests value noReset(1) is returned.rw Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.2.3.1.1.3 |
controlTempLimitHiHiModule temperature HiHi (high alarm) limit in 0.1 degC.rw INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.2.3.1.1.4 |
controlTempLimitHiModule temperature Hi (high warning) limit in 0.1 degC.rw INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.2.3.1.1.5 |
controlTempLimitLoModule temperature Lo (low warning) limit in 0.1 degC.rw INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.2.3.1.1.7 |
controlTempLimitLoLoModule temperature LoLo (low alarm) limit in 0.1 degC.rw INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.2.3.1.1.8 |
controlTempDeadBandModule temperature alarm/warning deadband in 0.1 degC. Common
to all limit values (LoLo, Lo, Hi, HiHi). The deadband defines
the difference between the 'ON' limit and the 'OFF' limit of
the corresponding alarm.
Example: The Hi limit is 65 degC and the deadband is 5 degC.
The high warning is activated when the temperature exceeds
65 degC and deactivated only after it falls below 60 degC.rw INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.2.3.1.1.9 |
controlInternalAppAccessThis object defines whether the internal controller application
is able to access the module parameters. This corresponds
to the BXX module setting 'Allow Functions'.
1 = allow internal control
2 = deny internal control (remote control is possible)rw Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.2.3.1.1.10 |
controlLocalAccessThis object defines whether the local user interface
(buttons, knobs etc.) is enabled or disabled. Values:
1 = disabled, local UI is locked
2 = enabled, local UI is active
For modules/devices with no local UI this objects should
return value 'disabled (1).rw Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.2.3.1.1.11 |
moduleSWUpdateTableA table of software update control objects. SEQUENCE OF ModuleSWUpdateEntry .1.3.6.1.4.1.5003.9.10.3.1.1.2.3.2 |
moduleSWUpdateEntry ModuleSWUpdateEntry .1.3.6.1.4.1.5003.9.10.3.1.1.2.3.2.1 |
sWUpdateControlWriting value updateStart(4) commands the module to run a software
update. The software image location and file name are specified in
sWUpdateURL and sWUpdateFilename.
Writing a updateIdle(1) when the update is running will terminate the
update process immediately. Writing any value when no update is
runnign has no effect.
Reading this object returns either updateIdle(1), updateRunning(2) or
updateFailed(3) depending on the status of the (last) software update.rw Enumeration .1.3.6.1.4.1.5003.9.10.3.1.1.2.3.2.1.1 |
swUpdateURLThe URL where the software image can be downloaded.
Format e.g. TFTP:\\downloads\swupdate\.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5003.9.10.3.1.1.2.3.2.1.2 |
sWUpdateFileNameFile name of the software image file to be downloaded.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5003.9.10.3.1.1.2.3.2.1.3 |
sWUpdateStatusDescription of the software update result.
After successful update this object should return a string
'Software updated successfully on <date and time>'. If the update failed
the returned value should be 'Software update failed'.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5003.9.10.3.1.1.2.3.2.1.4 |
moduleRegistry OBJECT IDENTIFIER .1.3.6.1.4.1.5003.9.10.3.1.1.2.4 |
moduleSizeOfTableThis table defines maximum number of entries
in the registry tables. All the registry tables have
fixed size defined in this table. SEQUENCE OF ModuleSizeOfEntry .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.1 |
moduleSizeOfEntry ModuleSizeOfEntry .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.1.1 |
sizeOfRegistryMax number of entries in the registryTable.
The entries in the registryTable are numbered
from 1..sizeofRegistry.ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.1.1.1 |
sizeOfRepairlogMax number of entries in the repairlogTable.
First entry (oldest entry) is deleted, when a new
entry is added and the table is full.ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.1.1.2 |
sizeOfNotebookMax number of entries in the notebookTable.
The lines in the notebookTable are numbered from
1..sizeofNotebook.ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.1.1.3 |
moduleRegistryTableThis table lists user data for all modules
installed inside the element.
Table is indexed by the moduleId and regIndex.
regIndex can have values 1..sizeofRegistry.
A registryEntry is 'deleted' by setting its name
to an empty string. SEQUENCE OF ModuleRegistryEntry .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.2 |
moduleRegistryEntry ModuleRegistryEntry .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.2.1 |
regIndexA second index to registryTable.
Can have values 1..sizeofRegistryTable.ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.2.1.1 |
regNameDescriptive name for the parameter.
The agent is allowed to limit the length of the name.
Minimum length of eight characters must be supported.
Writing empty string to this object removes it from the
registryTable.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.2.1.2 |
regValueTextual information describing the parameter information.
The agent is allowed to limit the length of the name.
Minimum length of eight characters must be supported.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.2.1.3 |
moduleRepairLogTableThis table contains repair history entries for modules
in the element. The table is indexed with moduleId and
repairLogDate.
The table can have sizeofRepairlog number of entries.
If this number is exceeded when writing a new entry,
the oldest entry is deleted and and a new entry is added. SEQUENCE OF ModuleRepairLogEntry .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.3 |
moduleRepairLogEntryRow entry in RepairLogTable.
Note that it uses double index: moduleId repairIndex.
that uniquely identify each log entry. Rows for particular
module exist only if there is row, that represents this
module in the moduleTable.
A row is 'deleted' by giving a date 0000-00-00. ModuleRepairLogEntry .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.3.1 |
repairIndexRow number of the Repairlog entry. Can have values
between 1..sizeOfRepairlog. This field is a second index
to moduleRepairLogTable.ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.3.1.1 |
repairDateDate of this repair entry formatted as CCYY-MM-DD.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.3.1.2 |
repairReasonCodeRepair code for this entry.rw OCTET STRING .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.3.1.3 |
repairNameCodeRepairer name code (initials) for this entry.rw OCTET STRING .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.3.1.4 |
repairCommentComment of the repair event.
The agent is allowed to truncate the length of the
comment, if it is too long to internal storage.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.3.1.5 |
moduleNotebookTableNotebook is a free text area for manager or serviceman
notes. It is divided into 50 character long character
blocks or lines. Each line is an entry in the
notebookTable.
Indices are moduleName and lineNumber.
A new line with the same lineNumber overwrites
the old line. SEQUENCE OF ModuleNotebookEntry .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.4 |
moduleNotebookEntry ModuleNotebookEntry .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.4.1 |
notebookLineNumberThe line number of the notebookTextLine.
The number must be in between 1..sizeofNotebook.
inclusive. Numbers should be used consecutively.ro INTEGER .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.4.1.1 |
notebookLineTextText field for storing notes about the module.rw OCTET STRING .1.3.6.1.4.1.5003.9.10.3.1.1.2.4.4.1.2 |