Home/Catalog/SURESINE

SURESINE

AI MIB Summary

The SURESINE MIB module enables SNMP-based monitoring and management of Morningstar SureSine solar inverters, providing access to critical operational metrics such as DC/AC power output, battery voltage and current, grid synchronization status, and device temperature.

Morningstar Product: SureSine Copyright (C) Morningstar Corporation (2019). All Rights Reserved
Main OID:
suresine.1.3.6.1.4.1.33333.9
10
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

10 total
Object Name
suresineMorningstar Product: SureSine Copyright (C) Morningstar Corporation (2019). All Rights Reserved
MODULE-IDENTITY
.1.3.6.1.4.1.33333.9
subModelThe device's exact modelro
DisplayString
.1.3.6.1.4.1.33333.9.1
serialNumberDevice Serial Numberro
DisplayString
.1.3.6.1.4.1.33333.9.2
deviceVersionHardware and firmware versions: vHW1.HW2.FWro
DisplayString
.1.3.6.1.4.1.33333.9.3
batteryVoltageSlowBattery Voltage(slow) - Description: Battery Voltage(slow) - Scaling Factor: 0.0002581787109375 - Units: V - Range: [0.0, 17.0] - Modbus address: 0x0004ro
Unsigned32
.1.3.6.1.4.1.33333.9.30
acCurrentAC Current - Description: AC Output Current - Scaling Factor: 0.0001953125 - Units: A - Range: [0.0, 17] - Modbus address: 0x0005ro
Unsigned32
.1.3.6.1.4.1.33333.9.31
heatsinkTemperatureHeatsink Temperature - Description: Heatsink Temperature - Scaling Factor: 1 - Units: C - Range: [-128, 127] - Modbus address: 0x0006ro
Integer32
.1.3.6.1.4.1.33333.9.32
loadStateLoad State - Description: Load State - Modbus address: 0x000Bro
LoadStateEnum
.1.3.6.1.4.1.33333.9.33
alarmsAlarms - Description: Alarms - Modbus address: 0x0008ro
AlarmsBitfield
.1.3.6.1.4.1.33333.9.34
faultsFaults - Description: Faults - Modbus address: 0x0007ro
FaultsBitfield
.1.3.6.1.4.1.33333.9.35

More MIBs from morningstar

Browse all morningstarMIBs →
C-PRODUCT-TRAP-MIB

Standard SNMP MIB module defining data structures for C-PRODUCT-TRAP-MIB.

181 objects→
GENSTAR

The GENSTAR MIB module facilitates SNMP-based monitoring and management of Morningstar GenStar solar charge controllers and inverters, exposing operational metrics such as battery voltage, current, state of charge, and system status via Modbus-to-SNMP translation.

139 objects→
PROSTAR-MPPT

The PROSTAR-MPPT MIB module enables SNMP-based monitoring and management of Morningstar Prostar Maximum Power Point Tracking (MPPT) solar charge controllers, exposing telemetry for photovoltaic array voltage, current, power output, battery bank status, and system efficiency metrics.

60 objects→
PROSTAR-PWM

The PROSTAR-PWM MIB module enables SNMP-based monitoring and management of Morningstar Prostar Pulse Width Modulation (PWM) solar charge controllers, exposing device-specific telemetry such as battery voltage, charging current, solar input status, and internal temperature. It facilitates the collection of operational state data and alarm conditions for these specific solar power management devices within a networked infrastructure.

53 objects→
SUNSAVER-MPPT

The SUNSAVER-MPPT MIB module enables SNMP-based monitoring and management of Morningstar SunSaver MPPT solar charge controllers, specifically facilitating the retrieval of photovoltaic system telemetry such as input/output voltage, current, power, and battery state-of-charge. This module supports the device's Meterbus interface (Type 5) to aggregate critical charging parameters for remote system health assessment and performance analysis.

52 objects→
TRISTAR-MPPT

The TRISTAR-MPPT MIB module enables SNMP-based monitoring and management of Morningstar TriStar-MPPT solar charge controllers, specifically exposing metrics for photovoltaic input voltage and current, battery bank status, and MPPT tracking efficiency. This module facilitates the collection of real-time operational data and alarm states required for remote system health assessment and performance analysis of solar power installations.

44 objects→