SP2-MIB
AI MIB Summary
The SP2-MIB facilitates SNMP-based monitoring and management of ELTEK SmartPack, Compack, and WebPower software-defined power systems across distributed and OEM hardware branches. It exposes device-specific telemetry including branch identifiers, software version levels, and operational status for ELTEK power distribution units and embedded controllers.
An ongoing effort toward a generic MIB for all ELTEK products. Branch overview: Aeongold branch will be 1 AL175 branch will be 2 AL6000 branch will be 3 Internal used branch will be 4 Internal used branch will be 5 OEM Smartpack branch will be 6 ELTEK Common branch will be 7 (SmartPack, MCU, AEON w/WebPower sw V2.x) ELTEK Distributed branch will be 8 (SmartPack w/WebPower sw V3.x) ELTEK Distributed V2 branch will be 9 (SmartPack w/WebPower sw V4.0) ELTEK Distributed V3 branch will be 9 (SmartPack w/WebPower sw V4.1) ELTEK Distributed V4 branch will be 9 (SmartPack w/WebPower sw V4.1, V4.2, V4.3, V4.5 and compack V1.0, V1.01, V1.02, V1.03) ELTEK Distributed V5 branch will be 9 (SmartPack w/WebPower sw V4.1, V4.2, V4.3, V4.5, V4.6) ELTEK Distributed V6 branch will be 9 (SmartPack2 sw V1.1, V1.2, V1.3) ELTEK Distributed V7 branch will be 9 (SmartPack w/WebPower sw V4.1, V4.2, V4.3, V4.5, V4.6, V4.7 and compack V1.xx) ELTEK eNexus MIB branch will be 10 (SmartPack2 and Compack) ELTEK Brasil office will have branch 11
Main OID:
eltek.1.3.6.1.4.1.12148
893
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
893 total| Object Name |
|---|
eltekAn ongoing effort toward a generic MIB for all ELTEK products. Branch overview: Aeongold branch will be 1 AL175 branch will be 2 AL6000 branch will be 3 Internal used branch will be 4 Internal used branch will be 5 OEM Smartpack branch will be 6 ELTEK Common branch will be 7 (SmartPack, MCU, AEON w/WebPower sw V2.x) ELTEK Distributed branch will be 8 (SmartPack w/WebPower sw V3.x) ELTEK Distributed V2 branch will be 9 (SmartPack w/WebPower sw V4.0) ELTEK Distributed V3 branch will be 9 (SmartPack w/WebPower sw V4.1) ELTEK Distributed V4 branch will be 9 (SmartPack w/WebPower sw V4.1, V4.2, V4.3, V4.5 and compack V1.0, V1.01, V1.02, V1.03) ELTEK Distributed V5 branch will be 9 (SmartPack w/WebPower sw V4.1, V4.2, V4.3, V4.5, V4.6) ELTEK Distributed V6 branch will be 9 (SmartPack2 sw V1.1, V1.2, V1.3) ELTEK Distributed V7 branch will be 9 (SmartPack w/WebPower sw V4.1, V4.2, V4.3, V4.5, V4.6, V4.7 and compack V1.xx) ELTEK eNexus MIB branch will be 10 (SmartPack2 and Compack) ELTEK Brasil office will have branch 11 MODULE-IDENTITY .1.3.6.1.4.1.12148 |
eNexus OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10 |
eltekTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.1 |
powerAlarmVars OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.1.1 |
alarmSubsysSourceDescrA description of the source generating the trap for the Alarm Condition. Used in alarmSubSystemTrap to describe the alarm source. Example: 'batteryVoltageDescription'ro DisplayString .1.3.6.1.4.1.12148.10.1.1.1 |
alarmSubsysStatusOidThe OID (name) of the object indicating the alarm-status for which the alarm is generated. The Status must be an INTEGER type. Example: SP2-MIB::batteryVoltage.batteryVoltageStatus 1.3.6.1.4.1.12148.10.3.5.2: This object maybe polled by the SNMP management application, to monitor the current Status object.ro OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.1.1.2 |
alarmSubsysStatusValueThe value of the Status object of the subsystem for which the alarm-status is generated. The OID (name) of this object is indicated by alarmSubsysStatusOid above. Example: the value of SP2-MIB::batteryVoltage.batteryVoltageStatus one of: error (0), normal (1), minorAlarm (2), etc.ro Enumeration .1.3.6.1.4.1.12148.10.1.1.3 |
alarmSubsysStatusOnOffThis indicates if the abnormal condition is on or goes off.ro Enumeration .1.3.6.1.4.1.12148.10.1.1.4 |
alarmMeasuredVarOidThe OID (name) of the measured-object indicating some measurement (e.g voltage) for which the alarm is generated. Example: SP2-MIB::batteryVoltage.batteryVoltageValue 1.3.6.1.4.1.12148.10.3.5.1 This object maybe polled by the SNMP management application, to monitor the current measurement.ro OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.1.1.5 |
alarmMeasuredVarValueThe value of the measured-object for which the alarm-status is generated, for example 13 volt. The actual value is in units defined by the actual variable (e.g volts). The units must use INTEGER type. The OID (name) of this object is indicated by alarmMeasuredVarOid above. Example: Value of SP2-MIB::batteryVoltage.batteryVoltageValue 'The measured battery voltage'ro Integer32 .1.3.6.1.4.1.12148.10.1.1.6 |
alarmTrapCounterVarValuero Integer32 .1.3.6.1.4.1.12148.10.1.1.7 |
powerSystemTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.1.2 |
alarmPowerSystemTrapThis Trap is sent when an alarm condition occurs in the power system. NOTIFICATION-TYPE .1.3.6.1.4.1.12148.10.1.2.1 |
alarmBatteryTrapThis Trap is sent when an alarm condition occurs in the battery subsystem. NOTIFICATION-TYPE .1.3.6.1.4.1.12148.10.1.2.2 |
alarmLoadGroupTrapThis Trap is sent when an alarm condition occurs in the Load subsystem. NOTIFICATION-TYPE .1.3.6.1.4.1.12148.10.1.2.3 |
alarmMainsTrapThis Trap is sent when an alarm condition occurs in the Mains subsystem. NOTIFICATION-TYPE .1.3.6.1.4.1.12148.10.1.2.4 |
alarmRectifierTrapThis Trap is sent when an alarm condition occurs in the Rectifier subsystem. NOTIFICATION-TYPE .1.3.6.1.4.1.12148.10.1.2.5 |
alarmControlSystemTrapThis Trap is sent when an alarm condition occurs in the Control-system subsystem. NOTIFICATION-TYPE .1.3.6.1.4.1.12148.10.1.2.6 |
alarmDcDcTrapThis Trap is sent when an alarm condition occurs in the DCDC converter subsystem. NOTIFICATION-TYPE .1.3.6.1.4.1.12148.10.1.2.7 |
alarmInputsTrapThis Trap is sent when an alarm condition occurs in the Inputs subsystem. NOTIFICATION-TYPE .1.3.6.1.4.1.12148.10.1.2.8 |
alarmOutputsTrapThis Trap is sent when an alarm condition occurs in the Outputs subsystem. NOTIFICATION-TYPE .1.3.6.1.4.1.12148.10.1.2.9 |
alarmGeneratorTrapThis Trap is sent when an alarm condition occurs in the Generator subsystem. NOTIFICATION-TYPE .1.3.6.1.4.1.12148.10.1.2.10 |
alarmSolarChargerTrapThis Trap is sent when an alarm condition occurs in the SolarCharger subsystem. NOTIFICATION-TYPE .1.3.6.1.4.1.12148.10.1.2.11 |
alarmWindChargerTrapThis Trap is sent when an alarm condition occurs in the WindCharger subsystem. NOTIFICATION-TYPE .1.3.6.1.4.1.12148.10.1.2.12 |
infoHeartBeatTrapWhen enabled, this trap will be transmitted at regular inervals. This trap is not intended to be an alarm but more like some information that the system is alive and the link is up. NOTIFICATION-TYPE .1.3.6.1.4.1.12148.10.1.2.13 |
powerSystemTrapsGroupThe powerSystem Trap goup. Entry point for the trap list. Unknown .1.3.6.1.4.1.12148.10.1.3 |
powerSystem OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.2 |
powerSystemStatusA status value showing the overall condition of the power system.ro Enumeration .1.3.6.1.4.1.12148.10.2.1 |
powerSystemTypeA value showing the type of the power system, which is named after the main controller.ro Enumeration .1.3.6.1.4.1.12148.10.2.2 |
powerSystemModeA summary status showing if the system is in test, boost or float modero Enumeration .1.3.6.1.4.1.12148.10.2.3 |
powerSystemCompanyThe Copmany name (as stored in the Control Unit).rw DisplayString .1.3.6.1.4.1.12148.10.2.4 |
powerSystemSiteThe system/site Location details (as stored in the Control Unit).rw DisplayString .1.3.6.1.4.1.12148.10.2.5 |
powerSystemModelThe model/part number of the power system (as stored in the Control Unit).ro DisplayString .1.3.6.1.4.1.12148.10.2.6 |
powerSystemSerialNumberThe serial number for the complete system.rw DisplayString .1.3.6.1.4.1.12148.10.2.7 |
powerSystemInstallDateThe system's Installation date (as stored in the Control Unit).rw DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.12148.10.2.8 |
powerSystemNominalVoltageThe nominal voltage rating. 12V/24V/48V/60V etc. systems.ro Integer32 .1.3.6.1.4.1.12148.10.2.9 |
powerSystemLongitudeA part of the systems global positioning data. The range +-180degrees Longitude lines are imaginary lines running from the north pole to the south pole. Longitudes are usually (WGS84) referenced from Greenwich, England where it has been established as Zero Degrees longitude. Latitude and Longitude together with the Elevation can be used for automagically placing system icons on NMS/Sitemonitors system that support this.rw Integer32 (-180..180) .1.3.6.1.4.1.12148.10.2.10 |
powerSystemLongitudeDecimalThe decimal part of dcSystemLatitude contains up to 7digits. This number is in 1/1000000 degree fractions or 0,0000001 degree. A part of the systems global positioning data. Longitude lines are imaginary lines running from the north pole to the south pole. Longitudes are usually (WGS84) referenced from Greenwich, England where it has been established as Zero Degrees longitude. Latitude and Longitude together with the Elevation can be used for automagically placing system icons on NMS/Sitemonitors system that support this.rw Integer32 .1.3.6.1.4.1.12148.10.2.11 |
powerSystemLatitudeA part of the systems global positioning data. The latitude gives the location of a place on Earth (or other planetary body) north or south of the equator. Lines of Latitude has a range of +-90 degrees and are the imaginary horizontal lines shown running east-to-west (or west to east). Latitude and Longitude together with the Elevation can be used for automagically placing system icons on NMS/Sitemonitors system that support this.rw Integer32 (-90..90) .1.3.6.1.4.1.12148.10.2.12 |
powerSystemLatitudeDecimalThe decimal part of dcSystemLatitude contains up to 7digits. This number is in 1/1000000 degree fractions or 0,0000001 degree. A part of the systems global positioning data. Lines of Latitude has a range of +-90 degrees and are the imaginary horizontal lines shown running east-to-west (or west to east). Latitude and Longitude together with the Elevation can be used for automagically placing system icons on NMS/Sitemonitors system that support this. Longitude lines are imaginary lines running from the north pole to the south pole. Longitudes are usually (WGS84) referenced from Greenwich, England where it has been established as Zero Degrees longitude. Latitude and Longitude together with the Elevation can be used for automagically placing system icons on NMS/Sitemonitors system that support this.rw Integer32 .1.3.6.1.4.1.12148.10.2.13 |
powerSystemElevationA part of the systems global positioning data. This is the sites height above sealevel in Meters. The Elevation together with Latituse and Longitude is used for automagically placing system icons on NMS/Sitemonitors system that support this.rw Integer32 .1.3.6.1.4.1.12148.10.2.14 |
powerSystemCurrentDecimalSettingA global flag telling if the current values in the system is Amperes or DeciAmpresrw Enumeration .1.3.6.1.4.1.12148.10.2.15 |
powerSystemTemperatureScaleA flag telling if the temperatures values in the system is of Celcius or Fahrenheit typerw Enumeration .1.3.6.1.4.1.12148.10.2.16 |
powerSystemCapacityScaleA flag telling if the system's battery capacity value is a percentage of a fully charged battery, or in AmpereHoursrw Enumeration .1.3.6.1.4.1.12148.10.2.17 |
mains OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.3 |
mainsStatusThe overall status of mains/AC feed subsystem.ro Enumeration .1.3.6.1.4.1.12148.10.3.1 |
mainsMainsFailure OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.3.2 |
mainsMainsFailureStatusThis status value shows if the number of failed phases is higher than the defined alarm level.ro Enumeration .1.3.6.1.4.1.12148.10.3.2.1 |
mainsMainsFailureDescriptionA textual description of the mains phase failure monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.3.2.2 |
mainsMainsFailureTrapRepeatCounterThe number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off.ro Integer32 .1.3.6.1.4.1.12148.10.3.2.3 |
mainsMainsFailureAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.3.2.4 |
mainsMainsFailureValueThe detected number of failed phases.ro Integer32 .1.3.6.1.4.1.12148.10.3.2.5 |
mainsMainsFailureMajorAlarmLevelThe major alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.3.2.6 |
mainsMainsFailureMinorAlarmLevelThe minor alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.3.2.7 |
mainsNumberOfPhasesThis value showing the number of phases of the mains subsystem.rw Integer32 .1.3.6.1.4.1.12148.10.3.3 |
mainsVoltageTableThis table contains information about mains voltage monitor SEQUENCE OF MainsVoltageEntry .1.3.6.1.4.1.12148.10.3.4 |
mainsVoltageEntry MainsVoltageEntry .1.3.6.1.4.1.12148.10.3.4.1 |
mainsVoltageIndexIndex used for navigating the rows 1..12 of mainsVoltageTable Integer32 .1.3.6.1.4.1.12148.10.3.4.1.1 |
mainsVoltageStatusThe status of the measured mains voltage.ro Enumeration .1.3.6.1.4.1.12148.10.3.4.1.2 |
mainsVoltageDescriptionA textual description of the mains voltage monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.3.4.1.3 |
mainsVoltageTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.3.4.1.4 |
mainsVoltageAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.3.4.1.5 |
mainsVoltageValueThe value of the measured mains voltage.ro Integer32 .1.3.6.1.4.1.12148.10.3.4.1.6 |
mainsVoltageMajorHighLevelThe major high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.3.4.1.7 |
mainsVoltageMinorHighLevelThe minor high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.3.4.1.8 |
mainsVoltageMinorLowLevelThe minor low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.3.4.1.9 |
mainsVoltageMajorLowLevelThe major low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.3.4.1.10 |
mainsMonitors OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.3.5 |
mainsMonitorsNumberOfUnitsThis is the number of AC Mains Monitor CAN Nodes installed in the system.rw Integer32 .1.3.6.1.4.1.12148.10.3.5.1 |
mainsMonitorsTableThis table contains the number of voltage, current and frequency measurements in each AC Mains Monitor SEQUENCE OF MainsMonitorsEntry .1.3.6.1.4.1.12148.10.3.5.2 |
mainsMonitorsEntry MainsMonitorsEntry .1.3.6.1.4.1.12148.10.3.5.2.1 |
mainsMonitorIndexIndex used for navigating the rows of mainsMonitorsTable The size of the table is defined by the system Integer32 .1.3.6.1.4.1.12148.10.3.5.2.1.1 |
mainsMonitorNumberOfVoltagesThe number of voltage measurements in the AC Mains Monitorro Integer32 .1.3.6.1.4.1.12148.10.3.5.2.1.2 |
mainsMonitorNumberOfCurrentsThe number of current measurements in the AC Mains Monitorro Integer32 .1.3.6.1.4.1.12148.10.3.5.2.1.3 |
mainsMonitorNumberOfFrequenciesThe number of frequency measurements in the AC Mains Monitorro Integer32 .1.3.6.1.4.1.12148.10.3.5.2.1.4 |
mainsMonitorVoltageTableThis table contains information about mains voltage in AC Mains Monitor SEQUENCE OF MainsMonitorVoltageEntry .1.3.6.1.4.1.12148.10.3.5.3 |
mainsMonitorVoltageEntry MainsMonitorVoltageEntry .1.3.6.1.4.1.12148.10.3.5.3.1 |
mainsMonitorPhaseIndexIndex used for navigating the rows 1..3 of mainsMonitorVolatgeTable Integer32 .1.3.6.1.4.1.12148.10.3.5.3.1.1 |
mainsMonitorVoltageStatusThe status of the measured mains voltage in AC Mains Monitor.ro Enumeration .1.3.6.1.4.1.12148.10.3.5.3.1.2 |
mainsMonitorVoltageDescriptionA textual description of the mains voltage in AC Mains Monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.3.5.3.1.3 |
mainsMonitorVoltageTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.3.5.3.1.4 |
mainsMonitorVoltageAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.3.5.3.1.5 |
mainsMonitorVoltageValueThe value of the measured mains voltage in AC Mains Monitor.ro Integer32 .1.3.6.1.4.1.12148.10.3.5.3.1.6 |
mainsMonitorVoltageMajorHighLevelThe major high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.3.5.3.1.7 |
mainsMonitorVoltageMinorHighLevelThe minor high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.3.5.3.1.8 |
mainsMonitorVoltageMinorLowLevelThe minor low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.3.5.3.1.9 |
mainsMonitorVoltageMajorLowLevelThe major low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.3.5.3.1.10 |
mainsMonitorCurrentTableThis table contains information about mains current in AC Mains Monitor SEQUENCE OF MainsMonitorCurrentEntry .1.3.6.1.4.1.12148.10.3.5.4 |
mainsMonitorCurrentEntry MainsMonitorCurrentEntry .1.3.6.1.4.1.12148.10.3.5.4.1 |
mainsMonitorCurrentStatusThe status of the measured mains current in AC Mains Monitor.ro Enumeration .1.3.6.1.4.1.12148.10.3.5.4.1.1 |
mainsMonitorCurrentDescriptionA textual description of the mains current in AC Mains Monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.3.5.4.1.2 |
mainsMonitorCurrentTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.3.5.4.1.3 |
mainsMonitorCurrentAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.3.5.4.1.4 |
mainsMonitorCurrentValueThe value of the measured mains current in AC Mains Monitor.ro Integer32 .1.3.6.1.4.1.12148.10.3.5.4.1.5 |
mainsMonitorCurrentMajorHighLevelThe major high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.3.5.4.1.6 |
mainsMonitorCurrentMinorHighLevelThe minor high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.3.5.4.1.7 |
mainsMonitorFrequencyTableThis table contains information about mains frequency in AC Mains Monitor SEQUENCE OF MainsMonitorFrequencyEntry .1.3.6.1.4.1.12148.10.3.5.5 |
mainsMonitorFrequencyEntry MainsMonitorFrequencyEntry .1.3.6.1.4.1.12148.10.3.5.5.1 |
mainsMonitorFrequencyStatusThe status of the measured mains frequency in AC Mains Monitor.ro Enumeration .1.3.6.1.4.1.12148.10.3.5.5.1.1 |
mainsMonitorFrequencyDescriptionA textual description of the mains frequency in AC Mains Monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.3.5.5.1.2 |
mainsMonitorFrequencyTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.3.5.5.1.3 |
mainsMonitorFrequencyAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.3.5.5.1.4 |
mainsMonitorFrequencyValueThe value of the measured mains frequency in AC Mains Monitor.ro Integer32 .1.3.6.1.4.1.12148.10.3.5.5.1.5 |
mainsMonitorFrequencyMajorHighLevelThe major high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.3.5.5.1.6 |
mainsMonitorFrequencyMinorHighLevelThe minor high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.3.5.5.1.7 |
mainsMonitorFrequencyMinorLowLevelThe minor low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.3.5.5.1.8 |
mainsMonitorFrequencyMajorLowLevelThe major low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.3.5.5.1.9 |
mainsMonitorEnergyLogAccumulatedTableThis table contains the accumulated energy consumption measured in AC Mains Monitor SEQUENCE OF MainsMonitorEnergyLogAccumulatedEntry .1.3.6.1.4.1.12148.10.3.5.6 |
mainsMonitorEnergyLogAccumulatedEntry MainsMonitorEnergyLogAccumulatedEntry .1.3.6.1.4.1.12148.10.3.5.6.1 |
mainsMonitorEnergyLogAccumulatedThe accumulated energy consumption valuero Integer32 .1.3.6.1.4.1.12148.10.3.5.6.1.1 |
mainsMonitorEnergyLogLastHoursNumberOfEntriesThis is the maximal number of entries stored in hourly energy logro Integer32 .1.3.6.1.4.1.12148.10.3.5.7 |
mainsMonitorEnergyLogLastHoursTableThis table contains energy consumption values logged every hour in AC Mains Monitor. SEQUENCE OF MainsMonitorEnergyLogLastHoursEntry .1.3.6.1.4.1.12148.10.3.5.8 |
mainsMonitorEnergyLogLastHoursEntry MainsMonitorEnergyLogLastHoursEntry .1.3.6.1.4.1.12148.10.3.5.8.1 |
mainsMonitorEnergyLogLastHoursIndexIndex used for navigating the rows 1..52 of mainsMonitorEnergyLogLastHoursTable Integer32 .1.3.6.1.4.1.12148.10.3.5.8.1.1 |
mainsMonitorEnergyLogLastHoursValueEnergy consumption value logged every hour in AC Mains Monitor.ro Integer32 .1.3.6.1.4.1.12148.10.3.5.8.1.2 |
mainsMonitorEnergyLogLastDaysNumberOfEntriesThis is the maximal number of entries stored in daily energy logro Integer32 .1.3.6.1.4.1.12148.10.3.5.9 |
mainsMonitorEnergyLogLastDaysTableThis table contains energy consumption values logged every day in AC Mains Monitor. SEQUENCE OF MainsMonitorEnergyLogLastDaysEntry .1.3.6.1.4.1.12148.10.3.5.10 |
mainsMonitorEnergyLogLastDaysEntry MainsMonitorEnergyLogLastDaysEntry .1.3.6.1.4.1.12148.10.3.5.10.1 |
mainsMonitorEnergyLogLastDaysIndexIndex used for navigating the rows 1..52 of mainsMonitorEnergyLogLastDaysTable Integer32 .1.3.6.1.4.1.12148.10.3.5.10.1.1 |
mainsMonitorEnergyLogLastDaysValueEnergy consumption value logged every day in AC Mains Monitor.ro Integer32 .1.3.6.1.4.1.12148.10.3.5.10.1.2 |
mainsMonitorEnergyLogLastWeeksNumberOfEntriesThis is the maximal number of entries stored in weekly energy logro Integer32 .1.3.6.1.4.1.12148.10.3.5.11 |
mainsMonitorEnergyLogLastWeeksTableThis table contains energy consumption values logged every week in AC Mains Monitor. SEQUENCE OF MainsMonitorEnergyLogLastWeeksEntry .1.3.6.1.4.1.12148.10.3.5.12 |
mainsMonitorEnergyLogLastWeeksEntry MainsMonitorEnergyLogLastWeeksEntry .1.3.6.1.4.1.12148.10.3.5.12.1 |
mainsMonitorEnergyLogLastWeeksIndexIndex used for navigating the rows 1..52 of mainsMonitorEnergyLogLastWeeksTable Integer32 .1.3.6.1.4.1.12148.10.3.5.12.1.1 |
mainsMonitorEnergyLogLastWeeksValueEnergy consumption value logged every week in AC Mains Monitor.ro Integer32 .1.3.6.1.4.1.12148.10.3.5.12.1.2 |
mainsOutageLog OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.3.6 |
mainsOutageTotalThis is the total mains outage time measured in hours.ro Integer32 .1.3.6.1.4.1.12148.10.3.6.1 |
mainsOutageLogDaysNumberOfEntriesThis is the maximal number of entries stored in daily mains outage log.ro Integer32 .1.3.6.1.4.1.12148.10.3.6.2 |
mainsOutageLogDaysTableThis table contains daily mains outage time log. SEQUENCE OF MainsOutageLogDaysEntry .1.3.6.1.4.1.12148.10.3.6.3 |
mainsOutageLogDaysEntry MainsOutageLogDaysEntry .1.3.6.1.4.1.12148.10.3.6.3.1 |
mainsOutageLogDaysIndexIndex used for navigating the rows 1..52 of mainsOutageLogDaysTable Integer32 .1.3.6.1.4.1.12148.10.3.6.3.1.1 |
mainsOutageLogDaysValueMains outage time value in minutes, logged every day.ro Integer32 .1.3.6.1.4.1.12148.10.3.6.3.1.2 |
mainsOutageLogWeeksNumberOfEntriesThis is the maximal number of entries stored in weekly mains outage time log.ro Integer32 .1.3.6.1.4.1.12148.10.3.6.4 |
mainsOutageLogWeeksTableThis table contains weekly mains outage time log. SEQUENCE OF MainsOutageLogWeeksEntry .1.3.6.1.4.1.12148.10.3.6.5 |
mainsOutageLogWeeksEntry MainsOutageLogWeeksEntry .1.3.6.1.4.1.12148.10.3.6.5.1 |
mainsOutageLogWeeksIndexIndex used for navigating the rows 1..52 of mainsOutageLogWeeksTable Integer32 .1.3.6.1.4.1.12148.10.3.6.5.1.1 |
mainsOutageLogWeeksValueMains outage time value in hours, logged every week.ro Integer32 .1.3.6.1.4.1.12148.10.3.6.5.1.2 |
mainsOutageLogMonthsNumberOfEntriesThis is the maximal number of entries stored in monthly mains outage time log.ro Integer32 .1.3.6.1.4.1.12148.10.3.6.6 |
mainsOutageLogMonthsTableThis table contains monthly mains outage time log. SEQUENCE OF MainsOutageLogMonthsEntry .1.3.6.1.4.1.12148.10.3.6.7 |
mainsOutageLogMonthsEntry MainsOutageLogMonthsEntry .1.3.6.1.4.1.12148.10.3.6.7.1 |
mainsOutageLogMonthsIndexIndex used for navigating the rows 1..52 of mainsOutageLogMonthsTable Integer32 .1.3.6.1.4.1.12148.10.3.6.7.1.1 |
mainsOutageLogMonthsValueMains outage time value in hours, logged every month.ro Integer32 .1.3.6.1.4.1.12148.10.3.6.7.1.2 |
generator OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.4 |
generatorStatusThe overall status of generator subsystem.ro Enumeration .1.3.6.1.4.1.12148.10.4.1 |
generatorFailStatusThe status of generator failure monitor.ro Enumeration .1.3.6.1.4.1.12148.10.4.2 |
generatorActivationIndicate if the generator run output signal is activated.ro Integer32 .1.3.6.1.4.1.12148.10.4.3 |
generatorDischargeValueThis is the present discharge value in percentage of total capacity.ro Integer32 .1.3.6.1.4.1.12148.10.4.4 |
generatorMainsDelayElapsing time of mains failure.ro Integer32 .1.3.6.1.4.1.12148.10.4.5 |
generatorChargeTimeElapsing time of charging with generator running.ro Integer32 .1.3.6.1.4.1.12148.10.4.6 |
generatorCapacityControlledStartStopEnableBattery charge/discharge level control of starting and stopping of generatorrw Enumeration .1.3.6.1.4.1.12148.10.4.7 |
generatorCapacityStartOnDischargeLimitWhen the generatorCapacityControlled is enabled, the generator is started when the remaining battery capacity drops below this limit in percentage of the total capacity.rw Integer32 .1.3.6.1.4.1.12148.10.4.8 |
generatorCapacityStopOnChargeLimitWhen the generatorCapacityControlled is enabled, the generator is stopped when the remaining battery capacity is greater than this limit in percentage of the total capacity.rw Integer32 .1.3.6.1.4.1.12148.10.4.9 |
generatorCurrentLimitControlledStopEnableEnables the generator to stop when the charge current drops below generatorCurrentLimitControlledStopValue.rw Enumeration .1.3.6.1.4.1.12148.10.4.10 |
generatorCurrentLimitControlledStopValueGenerator stops when the charge current drop drops below this level.rw Integer32 .1.3.6.1.4.1.12148.10.4.11 |
generatorVoltageControlledStartEnableEnable/disable voltage controlled generator activation.rw Enumeration .1.3.6.1.4.1.12148.10.4.12 |
generatorVoltageControlStartVoltageThe voltage limit to start generator.rw Integer32 .1.3.6.1.4.1.12148.10.4.13 |
generatorVoltageControlStopAfterA time delay for stopping generator when generator is activated by voltage.rw Integer32 .1.3.6.1.4.1.12148.10.4.14 |
generatorDailyRunEnableEnable/disable generator daily run function.rw Enumeration .1.3.6.1.4.1.12148.10.4.15 |
generatorDailyRunSetupTableThis table contains configurations of generator daily run. SEQUENCE OF GeneratorDailyRunSetupEntry .1.3.6.1.4.1.12148.10.4.16 |
generatorDailyRunSetupEntry GeneratorDailyRunSetupEntry .1.3.6.1.4.1.12148.10.4.16.1 |
generatorDailyRunDayIndexIndex used for navigating the rows 1..7 of generatorDailyRunSetupTable Enumeration .1.3.6.1.4.1.12148.10.4.16.1.1 |
generatorDailyRunStartHourGenerator daily starting time.rw Integer32 .1.3.6.1.4.1.12148.10.4.16.1.2 |
generatorDailyRunStopHourGenerator daily stopping time.rw Integer32 .1.3.6.1.4.1.12148.10.4.16.1.3 |
generatorMonthlyRunEnableEnable/disable generator monthly run function.rw Enumeration .1.3.6.1.4.1.12148.10.4.17 |
generatorMonthlyRunStartTimeGenerator monthly run starting time.rw Integer32 .1.3.6.1.4.1.12148.10.4.18 |
generatorMonthlyRunStartDayinMonth1Generator monthly run starting day #1.rw Integer32 .1.3.6.1.4.1.12148.10.4.19 |
generatorMonthlyRunStartDayinMonth2Generator monthly run starting day #2.rw Integer32 .1.3.6.1.4.1.12148.10.4.20 |
generatorTankNumberOfTanksNumber of fuel tanks.ro Integer32 .1.3.6.1.4.1.12148.10.4.21 |
generatorTankTableThis table contains information about generator fuel tanks. SEQUENCE OF GeneratorTankEntry .1.3.6.1.4.1.12148.10.4.22 |
generatorTankEntry GeneratorTankEntry .1.3.6.1.4.1.12148.10.4.22.1 |
generatorTankIndexIndex used for navigating the rows 1..2 of generatorTankTable Integer32 .1.3.6.1.4.1.12148.10.4.22.1.1 |
generatorTankStatusThe status of the measured fuel level in tank.ro Enumeration .1.3.6.1.4.1.12148.10.4.22.1.2 |
generatorTankDescriptionA textual description of the fuel level monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.4.22.1.3 |
generatorTankTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.4.22.1.4 |
generatorTankEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.4.22.1.5 |
generatorTankValueThe value of the measured fuel level.ro Integer32 .1.3.6.1.4.1.12148.10.4.22.1.6 |
generatorTankMajorHighLevelThe major high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.4.22.1.7 |
generatorTankMinorHighLevelThe minor high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.4.22.1.8 |
generatorTankMinorLowLevelThe minor low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.4.22.1.9 |
generatorTankMajorLowLevelThe major low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.4.22.1.10 |
generatorEnergyLog OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.4.23 |
generatorEnergyLogAccumulatedThis is the accumulated energy delivered through rectifiers from generator.ro Integer32 .1.3.6.1.4.1.12148.10.4.23.1 |
generatorEnergyLogLastHoursNumberOfEntriesThis is the maximal number of entries stored in generator hourly energy log.ro Integer32 .1.3.6.1.4.1.12148.10.4.23.2 |
generatorEnergyLogLastHoursTableThis table contains hourly energy log of generator. SEQUENCE OF GeneratorEnergyLogLastHoursEntry .1.3.6.1.4.1.12148.10.4.23.3 |
generatorEnergyLogLastHoursEntry GeneratorEnergyLogLastHoursEntry .1.3.6.1.4.1.12148.10.4.23.3.1 |
generatorEnergyLogLastHoursIndexIndex used for navigating the rows 1..52 of generatorEnergyLogLastHoursTable Integer32 .1.3.6.1.4.1.12148.10.4.23.3.1.1 |
generatorEnergyLogLastHoursValueEnergy value logged every hour.ro Integer32 .1.3.6.1.4.1.12148.10.4.23.3.1.2 |
generatorEnergyLogLastDaysNumberOfEntriesThis is the maximal number of entries stored in generator daily energy log.ro Integer32 .1.3.6.1.4.1.12148.10.4.23.4 |
generatorEnergyLogLastDaysTableThis table contains daily energy log of generator. SEQUENCE OF GeneratorEnergyLogLastDaysEntry .1.3.6.1.4.1.12148.10.4.23.5 |
generatorEnergyLogLastDaysEntry GeneratorEnergyLogLastDaysEntry .1.3.6.1.4.1.12148.10.4.23.5.1 |
generatorEnergyLogLastDaysIndexIndex used for navigating the rows 1..52 of generatorEnergyLogLastDaysTable Integer32 .1.3.6.1.4.1.12148.10.4.23.5.1.1 |
generatorEnergyLogLastDaysValueEnergy value logged every dayro Integer32 .1.3.6.1.4.1.12148.10.4.23.5.1.2 |
generatorEnergyLogLastWeeksNumberOfEntriesThis is the maximal number of entries stored in generator weekly energy log.ro Integer32 .1.3.6.1.4.1.12148.10.4.23.6 |
generatorEnergyLogLastWeeksTableThis table contains weekly energy log of generator. SEQUENCE OF GeneratorEnergyLogLastWeeksEntry .1.3.6.1.4.1.12148.10.4.23.7 |
generatorEnergyLogLastWeeksEntry GeneratorEnergyLogLastWeeksEntry .1.3.6.1.4.1.12148.10.4.23.7.1 |
generatorEnergyLogLastWeeksIndexIndex used for navigating the rows 1..52 of generatorEnergyLogLastWeeksTable Integer32 .1.3.6.1.4.1.12148.10.4.23.7.1.1 |
generatorEnergyLogLastWeeksValueEnergy value logged every week.ro Integer32 .1.3.6.1.4.1.12148.10.4.23.7.1.2 |
generatorRunHoursLog OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.4.24 |
generatorRunHoursTotalHoursThis is the total generator running hours.ro Integer32 .1.3.6.1.4.1.12148.10.4.24.1 |
generatorRunHoursLogLastDaysNumberOfEntriesThis is the maximal number of entries stored in generator daily running hours log.ro Integer32 .1.3.6.1.4.1.12148.10.4.24.2 |
generatorRunHoursLogLastDaysTablegenerator running time in minutes SEQUENCE OF GeneratorRunHoursLogLastDaysEntry .1.3.6.1.4.1.12148.10.4.24.3 |
generatorRunHoursLogLastDaysEntry GeneratorRunHoursLogLastDaysEntry .1.3.6.1.4.1.12148.10.4.24.3.1 |
generatorRunHoursLogLastDaysIndexIndex used for navigating the rows 1..52 of generatorRunHoursLogLastDaysTable Integer32 .1.3.6.1.4.1.12148.10.4.24.3.1.1 |
generatorRunHoursLogLastDaysValueGenerator running time in minutes, logged every day.ro Integer32 .1.3.6.1.4.1.12148.10.4.24.3.1.2 |
generatorRunHoursLogLastWeeksNumberOfEntriesThis is the maximal number of entries stored in generator weekly running hours log.ro Integer32 .1.3.6.1.4.1.12148.10.4.24.4 |
generatorRunHoursLogLastWeeksTablegenerator running time in hours SEQUENCE OF GeneratorRunHoursLogLastWeeksEntry .1.3.6.1.4.1.12148.10.4.24.5 |
generatorRunHoursLogLastWeeksEntry GeneratorRunHoursLogLastWeeksEntry .1.3.6.1.4.1.12148.10.4.24.5.1 |
generatorRunHoursLogLastWeeksIndexIndex used for navigating the rows 1..52 of generatorRunHoursLogLastWeeksTable Integer32 .1.3.6.1.4.1.12148.10.4.24.5.1.1 |
generatorRunHoursLogLastWeeksValueGenerator running time in hours, logged every week.ro Integer32 .1.3.6.1.4.1.12148.10.4.24.5.1.2 |
generatorRunHoursLogLastMonthsNumberOfEntriesThis is the maximal number of entries stored in generator monthly running hours log.ro Integer32 .1.3.6.1.4.1.12148.10.4.24.6 |
generatorRunHoursLogLastMonthsTablegenerator running time in hours SEQUENCE OF GeneratorRunHoursLogLastMonthsEntry .1.3.6.1.4.1.12148.10.4.24.7 |
generatorRunHoursLogLastMonthsEntry GeneratorRunHoursLogLastMonthsEntry .1.3.6.1.4.1.12148.10.4.24.7.1 |
generatorRunHoursLogLastMonthsIndexIndex used for navigating the rows 1..52 of generatorRunHoursLogLastMonthsTable Integer32 .1.3.6.1.4.1.12148.10.4.24.7.1.1 |
generatorRunHoursLogLastMonthsValueGenerator running time in hours, logged every month.ro Integer32 .1.3.6.1.4.1.12148.10.4.24.7.1.2 |
generatorFuelConsumptionLog OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.4.25 |
generatorFuelConsumptionTotalUsedTableThis table contains total fuel consumption for each tank. SEQUENCE OF GeneratorFuelConsumptionTotalUsedEntry .1.3.6.1.4.1.12148.10.4.25.1 |
generatorFuelConsumptionTotalUsedEntry GeneratorFuelConsumptionTotalUsedEntry .1.3.6.1.4.1.12148.10.4.25.1.1 |
generatorFuelConsumptionTotalUsedTotal fuel consumption value.ro Integer32 .1.3.6.1.4.1.12148.10.4.25.1.1.1 |
generatorFuelConsumptionLogLastHoursNoOfEntriesThis is the maximal number of entries stored in generator hourly fuel consumption log.ro Integer32 .1.3.6.1.4.1.12148.10.4.25.2 |
generatorFuelConsumptionLogLastHoursTableThis table contains generator hourly fuel consumption log. SEQUENCE OF GeneratorFuelConsumptionLogLastHoursEntry .1.3.6.1.4.1.12148.10.4.25.3 |
generatorFuelConsumptionLogLastHoursEntry GeneratorFuelConsumptionLogLastHoursEntry .1.3.6.1.4.1.12148.10.4.25.3.1 |
generatorFuelConsumptionLogLastHoursIndexIndex used for navigating the rows 1..52 of generatorFuelConsumptionLogLastHoursTable Integer32 .1.3.6.1.4.1.12148.10.4.25.3.1.1 |
generatorFuelConsumptionLogLastHoursValueGenerator fuel consumption value, logged every hour.ro Integer32 .1.3.6.1.4.1.12148.10.4.25.3.1.2 |
generatorFuelConsumptionLogLastDaysNoOfEntriesThis is the maximal number of entries stored in generator daily fuel consumption log.ro Integer32 .1.3.6.1.4.1.12148.10.4.25.4 |
generatorFuelConsumptionLogLastDaysTableThis table contains generator daily fuel consumption log. SEQUENCE OF GeneratorFuelConsumptionLogLastDaysEntry .1.3.6.1.4.1.12148.10.4.25.5 |
generatorFuelConsumptionLogLastDaysEntry GeneratorFuelConsumptionLogLastDaysEntry .1.3.6.1.4.1.12148.10.4.25.5.1 |
generatorFuelConsumptionLogLastDaysIndexIndex used for navigating the rows 1..52 of generatorFuelConsumptionLogLastDaysTable Integer32 .1.3.6.1.4.1.12148.10.4.25.5.1.1 |
generatorFuelConsumptionLogLastDaysValueGenerator fuel consumption value, logged every day.ro Integer32 .1.3.6.1.4.1.12148.10.4.25.5.1.2 |
generatorFuelConsumptionLogLastWeeksNoOfEntriesThis is the maximal number of entries stored in generator weekly fuel consumption log.ro Integer32 .1.3.6.1.4.1.12148.10.4.25.6 |
generatorFuelConsumptionLogLastWeeksTableThis table contains generator weekly fuel consumption log. SEQUENCE OF GeneratorFuelConsumptionLogLastWeeksEntry .1.3.6.1.4.1.12148.10.4.25.7 |
generatorFuelConsumptionLogLastWeeksEntry GeneratorFuelConsumptionLogLastWeeksEntry .1.3.6.1.4.1.12148.10.4.25.7.1 |
generatorFuelConsumptionLogLastWeeksIndexIndex used for navigating the rows 1..52 of generatorFuelConsumptionLogLastWeeksTable Integer32 .1.3.6.1.4.1.12148.10.4.25.7.1.1 |
generatorFuelConsumptionLogLastWeeksValueGenerator fuel consumption value, logged every week.ro Integer32 .1.3.6.1.4.1.12148.10.4.25.7.1.2 |
rectifiers OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.5 |
rectifiersStatusThe overall status of rectifier subsystem.ro Enumeration .1.3.6.1.4.1.12148.10.5.1 |
rectifiersCurrent OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.5.2 |
rectifiersCurrentStatusThe status of the measured total rectifier current.ro Enumeration .1.3.6.1.4.1.12148.10.5.2.1 |
rectifiersCurrentDescriptionA textual description of the total rectifier current monitor. This is stored in the system controller and can be changed by the userrw DisplayString .1.3.6.1.4.1.12148.10.5.2.2 |
rectifiersCurrentTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.5.2.3 |
rectifiersCurrentAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.5.2.4 |
rectifiersCurrentValueThe value of the measured total rectifier current.ro Integer32 .1.3.6.1.4.1.12148.10.5.2.5 |
rectifiersCurrentMajorAlarmLevelThe major alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.5.2.6 |
rectifiersCurrentMinorAlarmLevelThe minor alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.5.2.7 |
rectifiersCapacity OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.5.3 |
rectifiersCapacityStatusThe status of the measured used rectifier capacity.ro Enumeration .1.3.6.1.4.1.12148.10.5.3.1 |
rectifiersCapacityDescriptionA textual description of the used rectifier capacity monitor. This is stored in the system controller and can be changed by the userrw DisplayString .1.3.6.1.4.1.12148.10.5.3.2 |
rectifiersCapacityTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.5.3.3 |
rectifiersCapacityAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.5.3.4 |
rectifiersCapacityValueThe used rectifier capacity value presented in percentage of the total installed rectifier capacity.ro Integer32 .1.3.6.1.4.1.12148.10.5.3.5 |
rectifiersCapacityMajorAlarmLevelThe major alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.5.3.6 |
rectifiersCapacityMinorAlarmLevelThe minor alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.5.3.7 |
rectifiersError OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.5.4 |
rectifiersErrorStatusThis status value shows if the number of failed units is higher than the defined alarm level.ro Enumeration .1.3.6.1.4.1.12148.10.5.4.1 |
rectifiersErrorDescriptionA textual description of the rectifier error monitor. This is stored in the system controller and can be changed by the userrw DisplayString .1.3.6.1.4.1.12148.10.5.4.2 |
rectifiersErrorTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.5.4.3 |
rectifiersErrorEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.5.4.4 |
rectifiersErrorValueThe number of failed rectifiers.ro Integer32 .1.3.6.1.4.1.12148.10.5.4.5 |
rectifiersErrorMajorAlarmLevelThe major alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.5.4.6 |
rectifiersErrorMinorAlarmLevelThe minor alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.5.4.7 |
rectifiersNumberOfRectifiersNumber of installed rectifiers.rw Integer32 .1.3.6.1.4.1.12148.10.5.5 |
rectifierTableThis table shows the information of each rectifier installed in the system. SEQUENCE OF RectifierEntry .1.3.6.1.4.1.12148.10.5.6 |
rectifierEntry RectifierEntry .1.3.6.1.4.1.12148.10.5.6.1 |
rectifierIndexIndex used for navigating the rows 1..100 of rectifierTable Integer32 .1.3.6.1.4.1.12148.10.5.6.1.1 |
rectifierStatusThe overall status of rectifier.ro Enumeration .1.3.6.1.4.1.12148.10.5.6.1.2 |
rectifierOutputCurrentValueThe output current value of rectifier.ro Integer32 .1.3.6.1.4.1.12148.10.5.6.1.3 |
rectifierInputVoltageValueThe input voltage value of rectifier.ro Integer32 .1.3.6.1.4.1.12148.10.5.6.1.4 |
rectifierTypeType of rectifierro DisplayString .1.3.6.1.4.1.12148.10.5.6.1.5 |
rectifierHwPartNumberHardware part number of rectifierro DisplayString .1.3.6.1.4.1.12148.10.5.6.1.6 |
rectifierHwVersionHardware version number of rectifierro DisplayString .1.3.6.1.4.1.12148.10.5.6.1.7 |
rectifierSwPartNumberPart number of secondary software in rectifierro DisplayString .1.3.6.1.4.1.12148.10.5.6.1.8 |
rectifierSwVersionVersion number of secondary software in rectifierro DisplayString .1.3.6.1.4.1.12148.10.5.6.1.9 |
rectifiersEnergyLog OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.5.7 |
rectifiersEnergyLogAccumulatedThis is the accumulated energy delivered from rectifiers.ro Integer32 .1.3.6.1.4.1.12148.10.5.7.1 |
rectifiersEnergyLogLastHoursNumberOfEntriesThis is the maximal number of entries stored in rectifier hourly energy log.ro Integer32 .1.3.6.1.4.1.12148.10.5.7.2 |
rectifiersEnergyLogLastHoursTableThis table contains hourly energy log of rectifiers. SEQUENCE OF RectifiersEnergyLogLastHoursEntry .1.3.6.1.4.1.12148.10.5.7.3 |
rectifiersEnergyLogLastHoursEntry RectifiersEnergyLogLastHoursEntry .1.3.6.1.4.1.12148.10.5.7.3.1 |
rectifiersEnergyLogLastHoursIndexIndex used for navigating the rows 1..52 of rectifiersEnergyLogLastHoursTable Integer32 .1.3.6.1.4.1.12148.10.5.7.3.1.1 |
rectifiersEnergyLogLastHoursValueEnergy value logged every hour.ro Integer32 .1.3.6.1.4.1.12148.10.5.7.3.1.2 |
rectifiersEnergyLogLastDaysNumberOfEntriesThis is the maximal number of entries stored in rectifier daily energy log.ro Integer32 .1.3.6.1.4.1.12148.10.5.7.4 |
rectifiersEnergyLogLastDaysTableThis table contains daily energy log of rectifiers. SEQUENCE OF RectifiersEnergyLogLastDaysEntry .1.3.6.1.4.1.12148.10.5.7.5 |
rectifiersEnergyLogLastDaysEntry RectifiersEnergyLogLastDaysEntry .1.3.6.1.4.1.12148.10.5.7.5.1 |
rectifiersEnergyLogLastDaysIndexIndex used for navigating the rows 1..52 of rectifiersEnergyLogLastDaysTable Integer32 .1.3.6.1.4.1.12148.10.5.7.5.1.1 |
rectifiersEnergyLogLastDaysValueEnergy value logged every day.ro Integer32 .1.3.6.1.4.1.12148.10.5.7.5.1.2 |
rectifiersEnergyLogLastWeeksNumberOfEntriesThis is the maximal number of entries stored in rectifier weekly energy log.ro Integer32 .1.3.6.1.4.1.12148.10.5.7.6 |
rectifiersEnergyLogLastWeeksTableThis table contains weekly energy log of rectifiers. SEQUENCE OF RectifiersEnergyLogLastWeeksEntry .1.3.6.1.4.1.12148.10.5.7.7 |
rectifiersEnergyLogLastWeeksEntry RectifiersEnergyLogLastWeeksEntry .1.3.6.1.4.1.12148.10.5.7.7.1 |
rectifiersEnergyLogLastWeeksIndexIndex used for navigating the rows 1..52 of rectifiersEnergyLogLastWeekTable Integer32 .1.3.6.1.4.1.12148.10.5.7.7.1.1 |
rectifiersEnergyLogLastWeeksValueEnergy value logged every week.ro Integer32 .1.3.6.1.4.1.12148.10.5.7.7.1.2 |
dcdc OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.6 |
dcdcNumberOfGroupsNumber of dcdc groupsro Integer32 .1.3.6.1.4.1.12148.10.6.1 |
dcdcGroupsTableThis table contains information about dcdc groups. SEQUENCE OF DcdcGroupsEntry .1.3.6.1.4.1.12148.10.6.2 |
dcdcGroupsEntry DcdcGroupsEntry .1.3.6.1.4.1.12148.10.6.2.1 |
dcdcGroupIndex Integer32 .1.3.6.1.4.1.12148.10.6.2.1.1 |
dcdcGroupStatusThe overall status of dcdc group.ro Enumeration .1.3.6.1.4.1.12148.10.6.2.1.2 |
dcdcGroupNumberOfDcdcConvertersNumber of installed dcdc converters.rw Integer32 .1.3.6.1.4.1.12148.10.6.2.1.3 |
dcdcGroupOutputVoltageOutput voltage of dcdc convertersrw Integer32 .1.3.6.1.4.1.12148.10.6.2.1.4 |
dcdcNumberOfCurrentsNumber of dcdc currentsro Integer32 .1.3.6.1.4.1.12148.10.6.2.1.5 |
dcdcNumberOfCapacitiesNumber of dcdc capacitiesro Integer32 .1.3.6.1.4.1.12148.10.6.2.1.6 |
dcdcNumberOfAlarmsNumber of dcdc alarmsro Integer32 .1.3.6.1.4.1.12148.10.6.2.1.7 |
dcdcCurrentTableThis table contains information about the total dcdc current. SEQUENCE OF DcdcCurrentEntry .1.3.6.1.4.1.12148.10.6.3 |
dcdcCurrentEntry DcdcCurrentEntry .1.3.6.1.4.1.12148.10.6.3.1 |
dcdcCurrentStatusThe status of the measured total dcdc current.ro Enumeration .1.3.6.1.4.1.12148.10.6.3.1.1 |
dcdcCurrentDescriptionA textual description of the total dcdc current monitor. This is stored in the system controller and can be changed by the userrw DisplayString .1.3.6.1.4.1.12148.10.6.3.1.2 |
dcdcCurrentTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.6.3.1.3 |
dcdcCurrentAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.6.3.1.4 |
dcdcCurrentValueThe value of the measured total dcdc current.ro Integer32 .1.3.6.1.4.1.12148.10.6.3.1.5 |
dcdcCurrentMajorAlarmLevelThe major alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.6.3.1.6 |
dcdcCurrentMinorAlarmLevelThe minor alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.6.3.1.7 |
dcdcCapacityTableThis table contains information about the used dcdc capacity. SEQUENCE OF DcdcCapacityEntry .1.3.6.1.4.1.12148.10.6.4 |
dcdcCapacityEntry DcdcCapacityEntry .1.3.6.1.4.1.12148.10.6.4.1 |
dcdcCapacityStatusThe status of the measured used dcdc capacity.ro Enumeration .1.3.6.1.4.1.12148.10.6.4.1.1 |
dcdcCapacityDescriptionA textual description of the used dcdc capacity monitor. This is stored in the system controller and can be changed by the userrw DisplayString .1.3.6.1.4.1.12148.10.6.4.1.2 |
dcdcCapacityTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes ofro Counter32 .1.3.6.1.4.1.12148.10.6.4.1.3 |
dcdcCapacityAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.6.4.1.4 |
dcdcCapacityValueThe used dcdc capacity value presented in percentage of the total installed dcdc capacity.ro Integer32 .1.3.6.1.4.1.12148.10.6.4.1.5 |
dcdcCapacityMajorAlarmLevelThe major alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.6.4.1.6 |
dcdcCapacityMinorAlarmLevelThe minor alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.6.4.1.7 |
dcdcTableThis table shows the information of each dcdc converter installed in the system. SEQUENCE OF DcdcEntry .1.3.6.1.4.1.12148.10.6.5 |
dcdcEntry DcdcEntry .1.3.6.1.4.1.12148.10.6.5.1 |
dcdcIndexIndex used for navigating the rows 1..100 of dcdcTable Integer32 .1.3.6.1.4.1.12148.10.6.5.1.1 |
dcdcStatusThe overall status of dcdc converterro Enumeration .1.3.6.1.4.1.12148.10.6.5.1.2 |
dcdcOutputCurrentValueThe output current value of dcdc.ro Integer32 .1.3.6.1.4.1.12148.10.6.5.1.3 |
dcdcInputVoltageValueThe input voltage value of dcdc.ro Integer32 .1.3.6.1.4.1.12148.10.6.5.1.4 |
dcdcTypeType of dcdc converterro DisplayString .1.3.6.1.4.1.12148.10.6.5.1.5 |
dcdcHwPartNumberHardware part number of dcdc converterro DisplayString .1.3.6.1.4.1.12148.10.6.5.1.6 |
dcdcHwVersionHardware version number of dcdc converterro DisplayString .1.3.6.1.4.1.12148.10.6.5.1.7 |
dcdcSwPartNumberPart number of secondary software in dcdc converterro DisplayString .1.3.6.1.4.1.12148.10.6.5.1.8 |
dcdcSwVersionVersion number of secondary software in dcdc converterro DisplayString .1.3.6.1.4.1.12148.10.6.5.1.9 |
dcdcErrorTableThis table contains information about the dcdc error monitor. SEQUENCE OF DcdcErrorEntry .1.3.6.1.4.1.12148.10.6.6 |
dcdcErrorEntry DcdcErrorEntry .1.3.6.1.4.1.12148.10.6.6.1 |
dcdcErrorStatusThis status value shows if the number of failed units is higher than the defined alarm level.ro Enumeration .1.3.6.1.4.1.12148.10.6.6.1.1 |
dcdcErrorDescriptionA textual description of the dcdc error monitor. This is stored in the system controller and can be changed by the userrw DisplayString .1.3.6.1.4.1.12148.10.6.6.1.2 |
dcdcErrorTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.6.6.1.3 |
dcdcErrorEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.6.6.1.4 |
dcdcErrorValueThe number of failed dcdc converters.ro Integer32 .1.3.6.1.4.1.12148.10.6.6.1.5 |
dcdcErrorMajorAlarmLevelThe major alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.6.6.1.6 |
dcdcErrorMinorAlarmLevelThe minor alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.6.6.1.7 |
dcdcEnergyLog OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.6.7 |
dcdcEnergyLogAccumulatedTableThis is the accumulated energy delivered from dcdc converters. SEQUENCE OF DcdcEnergyLogAccumulatedEntry .1.3.6.1.4.1.12148.10.6.7.1 |
dcdcEnergyLogAccumulatedEntry DcdcEnergyLogAccumulatedEntry .1.3.6.1.4.1.12148.10.6.7.1.1 |
dcdcEnergyLogAccumulatedThis is the accumulated energy delivered from dcdc converters.ro Integer32 .1.3.6.1.4.1.12148.10.6.7.1.1.1 |
dcdcEnergyLogLastHoursNumberOfEntriesThis is the maximal number of entries stored in dcdc hourly energy log.ro Integer32 .1.3.6.1.4.1.12148.10.6.7.2 |
dcdcEnergyLogLastHoursTableThis table contains hourly energy log of dcdc converters SEQUENCE OF DcdcEnergyLogLastHoursEntry .1.3.6.1.4.1.12148.10.6.7.3 |
dcdcEnergyLogLastHoursEntry DcdcEnergyLogLastHoursEntry .1.3.6.1.4.1.12148.10.6.7.3.1 |
dcdcEnergyLogLastHoursIndexIndex used for navigating the rows 1..52 of dcdcEnergyLogLastHoursTable Integer32 .1.3.6.1.4.1.12148.10.6.7.3.1.1 |
dcdcEnergyLogLastHoursValueEnergy value logged every hour.ro Integer32 .1.3.6.1.4.1.12148.10.6.7.3.1.2 |
dcdcEnergyLogLastDaysNumberOfEntriesThis is the maximal number of entries stored in dcdc daily energy log.ro Integer32 .1.3.6.1.4.1.12148.10.6.7.4 |
dcdcEnergyLogLastDaysTableThis table contains daily energy log of dcdc converters. SEQUENCE OF DcdcEnergyLogLastDaysEntry .1.3.6.1.4.1.12148.10.6.7.5 |
dcdcEnergyLogLastDaysEntry DcdcEnergyLogLastDaysEntry .1.3.6.1.4.1.12148.10.6.7.5.1 |
dcdcEnergyLogLastDaysIndexIndex used for navigating the rows 1..52 of dcdcEnergyLogLastDaysTable Integer32 .1.3.6.1.4.1.12148.10.6.7.5.1.1 |
dcdcEnergyLogLastDaysValueEnergy value logged every day.ro Integer32 .1.3.6.1.4.1.12148.10.6.7.5.1.2 |
dcdcEnergyLogLastWeeksNumberOfEntriesThis is the maximal number of entries stored in dcdc weekly energy log.ro Integer32 .1.3.6.1.4.1.12148.10.6.7.6 |
dcdcEnergyLogLastWeeksTableThis table contains weekly energy log of dcdc converters. SEQUENCE OF DcdcEnergyLogLastWeeksEntry .1.3.6.1.4.1.12148.10.6.7.7 |
dcdcEnergyLogLastWeeksEntry DcdcEnergyLogLastWeeksEntry .1.3.6.1.4.1.12148.10.6.7.7.1 |
dcdcEnergyLogLastWeeksIndexIndex used for navigating the rows 1..52 of dcdcEnergyLogLastWeekTable Integer32 .1.3.6.1.4.1.12148.10.6.7.7.1.1 |
dcdcEnergyLogLastWeeksValueEnergy value logged every week.ro Integer32 .1.3.6.1.4.1.12148.10.6.7.7.1.2 |
solarChargers OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.7 |
solarChargersStatusThe overall status of solar charger subsystem.ro Enumeration .1.3.6.1.4.1.12148.10.7.1 |
solarChargersCurrent OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.7.2 |
solarChargersCurrentStatusThe status of the measured total solar current.ro Enumeration .1.3.6.1.4.1.12148.10.7.2.1 |
solarChargersCurrentDescriptionA textual description of the total solar current monitor. This is stored in the system controller and can be changed by the userrw DisplayString .1.3.6.1.4.1.12148.10.7.2.2 |
solarChargersCurrentTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.7.2.3 |
solarChargersCurrentAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.7.2.4 |
solarChargersCurrentValueThe value of the measured total solar current.ro Integer32 .1.3.6.1.4.1.12148.10.7.2.5 |
solarChargersCurrentMajorAlarmLevelThe major alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.7.2.6 |
solarChargersCurrentMinorAlarmLevelThe minor alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.7.2.7 |
solarChargersCapacity OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.7.3 |
solarChargersCapacityStatusThe status of the measured used solar capacity.ro Enumeration .1.3.6.1.4.1.12148.10.7.3.1 |
solarChargersCapacityDescriptionA textual description of the used solar charger capacity monitor. This is stored in the system controller and can be changed by the userrw DisplayString .1.3.6.1.4.1.12148.10.7.3.2 |
solarChargersCapacityTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.7.3.3 |
solarChargersCapacityAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.7.3.4 |
solarChargersCapacityValueThe used solar capacity value presented in percentage of the total installed solar capacity.ro Integer32 .1.3.6.1.4.1.12148.10.7.3.5 |
solarChargersCapacityMajorAlarmLevelThe major alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.7.3.6 |
solarChargersCapacityMinorAlarmLevelThe minor alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.7.3.7 |
solarChargersError OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.7.4 |
solarChargersErrorStatusThis status value shows if the number of failed units is higher than the defined alarm level.ro Enumeration .1.3.6.1.4.1.12148.10.7.4.1 |
solarChargersErrorDescriptionA textual description of the solar error monitor. This is stored in the system controller and can be changed by the userrw DisplayString .1.3.6.1.4.1.12148.10.7.4.2 |
solarChargersErrorTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.7.4.3 |
solarChargersErrorEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.7.4.4 |
solarChargersErrorValueThe number of failed solar chargers.ro Integer32 .1.3.6.1.4.1.12148.10.7.4.5 |
solarChargersErrorMajorAlarmLevelThe major alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.7.4.6 |
solarChargersErrorMinorAlarmLevelThe minor alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.7.4.7 |
solarChargersNumberOfSolarChargersNumber of installed solar chargers.rw Integer32 .1.3.6.1.4.1.12148.10.7.5 |
solarChargerTableThis table shows the information of each solar charger installed in the system. SEQUENCE OF SolarChargerEntry .1.3.6.1.4.1.12148.10.7.6 |
solarChargerEntry SolarChargerEntry .1.3.6.1.4.1.12148.10.7.6.1 |
solarChargerIndexIndex used for navigating the rows 1..100 of solarChargerTable Integer32 .1.3.6.1.4.1.12148.10.7.6.1.1 |
solarChargerStatusThe overall status of solar charger.ro Enumeration .1.3.6.1.4.1.12148.10.7.6.1.2 |
solarChargerOutputCurrentValueThe output current value of solar charger.ro Integer32 .1.3.6.1.4.1.12148.10.7.6.1.3 |
solarChargerInputVoltageValueThe input voltage value of solar charger.ro Integer32 .1.3.6.1.4.1.12148.10.7.6.1.4 |
solarChargerTypeType of solar chargerro DisplayString .1.3.6.1.4.1.12148.10.7.6.1.5 |
solarChargerHwPartNumberHardware part number of solar chargerro DisplayString .1.3.6.1.4.1.12148.10.7.6.1.6 |
solarChargerHwVersionHardware version number of solar chargerro DisplayString .1.3.6.1.4.1.12148.10.7.6.1.7 |
solarChargerSwPartNumberPart number of secondary software in solar chargerro DisplayString .1.3.6.1.4.1.12148.10.7.6.1.8 |
solarChargerSwVersionVersion number of secondary software in solar chargerro DisplayString .1.3.6.1.4.1.12148.10.7.6.1.9 |
solarChargersEnergyLog OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.7.7 |
solarChargersEnergyLogAccumulatedThis is the accumulated energy delivered from solar chargers.ro Integer32 .1.3.6.1.4.1.12148.10.7.7.1 |
solarChargersEnergyLogLastHoursNumberOfEntriesThis is the maximal number of entries stored in solar charger hourly energy log.ro Integer32 .1.3.6.1.4.1.12148.10.7.7.2 |
solarChargersEnergyLogLastHoursTableThis table contains hourly energy log of solar chargers. SEQUENCE OF SolarChargersEnergyLogLastHoursEntry .1.3.6.1.4.1.12148.10.7.7.3 |
solarChargersEnergyLogLastHoursEntry SolarChargersEnergyLogLastHoursEntry .1.3.6.1.4.1.12148.10.7.7.3.1 |
solarChargersEnergyLogLastHoursIndexIndex used for navigating the rows 1..52 of solarChargersEnergyLogLastHoursTable Integer32 .1.3.6.1.4.1.12148.10.7.7.3.1.1 |
solarChargersEnergyLogLastHoursValueEnergy value logged every hour.ro Integer32 .1.3.6.1.4.1.12148.10.7.7.3.1.2 |
solarChargersEnergyLogLastDaysNumberOfEntriesThis is the maximal number of entries stored in solar charger daily energy log.ro Integer32 .1.3.6.1.4.1.12148.10.7.7.4 |
solarChargersEnergyLogLastDaysTableThis table contains daily energy log of solar chargers. SEQUENCE OF SolarChargersEnergyLogLastDaysEntry .1.3.6.1.4.1.12148.10.7.7.5 |
solarChargersEnergyLogLastDaysEntry SolarChargersEnergyLogLastDaysEntry .1.3.6.1.4.1.12148.10.7.7.5.1 |
solarChargersEnergyLogLastDaysIndexIndex used for navigating the rows 1..52 of solarChargersEnergyLogLastDaysTable Integer32 .1.3.6.1.4.1.12148.10.7.7.5.1.1 |
solarChargersEnergyLogLastDaysValueEnergy value logged every day.ro Integer32 .1.3.6.1.4.1.12148.10.7.7.5.1.2 |
solarChargersEnergyLogLastWeeksNumberOfEntriesThis is the maximal number of entries stored in solar charger weekly energy log.ro Integer32 .1.3.6.1.4.1.12148.10.7.7.6 |
solarChargersEnergyLogLastWeeksTableThis table contains weekly energy log of solar chargers. SEQUENCE OF SolarChargersEnergyLogLastWeeksEntry .1.3.6.1.4.1.12148.10.7.7.7 |
solarChargersEnergyLogLastWeeksEntry SolarChargersEnergyLogLastWeeksEntry .1.3.6.1.4.1.12148.10.7.7.7.1 |
solarChargersEnergyLogLastWeeksIndexIndex used for navigating the rows 1..52 of solarChargersEnergyLogLastWeekTable Integer32 .1.3.6.1.4.1.12148.10.7.7.7.1.1 |
solarChargersEnergyLogLastWeeksValueEnergy value logged every week.ro Integer32 .1.3.6.1.4.1.12148.10.7.7.7.1.2 |
windChargers OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.8 |
windChargersStatusThe overall status of wind charger subsystem.ro Enumeration .1.3.6.1.4.1.12148.10.8.1 |
windChargersCurrent OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.8.2 |
windChargersCurrentStatusThe status of the measured total wind current.ro Enumeration .1.3.6.1.4.1.12148.10.8.2.1 |
windChargersCurrentDescriptionA textual description of the total wind current monitor. This is stored in the system controller and can be changed by the userrw DisplayString .1.3.6.1.4.1.12148.10.8.2.2 |
windChargersCurrentTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.8.2.3 |
windChargersCurrentAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.8.2.4 |
windChargersCurrentValueThe value of the measured total wind current.ro Integer32 .1.3.6.1.4.1.12148.10.8.2.5 |
windChargersCurrentMajorAlarmLevelThe major alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.8.2.6 |
windChargersCurrentMinorAlarmLevelThe minor alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.8.2.7 |
windChargersCapacity OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.8.3 |
windChargersCapacityStatusThe status of the measured used wind charger capacity.ro Enumeration .1.3.6.1.4.1.12148.10.8.3.1 |
windChargersCapacityDescriptionA textual description of the used wind charger capacity monitor. This is stored in the system controller and can be changed by the userrw DisplayString .1.3.6.1.4.1.12148.10.8.3.2 |
windChargersCapacityTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.8.3.3 |
windChargersCapacityAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.8.3.4 |
windChargersCapacityValueThe used wind charger capacity value presented in percentage of the total installed wind charger capacity.ro Integer32 .1.3.6.1.4.1.12148.10.8.3.5 |
windChargersCapacityMajorAlarmLevelThe major alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.8.3.6 |
windChargersCapacityMinorAlarmLevelThe minor alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.8.3.7 |
windChargersError OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.8.4 |
windChargersErrorStatusThis status value shows if the number of failed units is higher than the defined alarm level.ro Enumeration .1.3.6.1.4.1.12148.10.8.4.1 |
windChargersErrorDescriptionA textual description of the wind error monitor. This is stored in the system controller and can be changed by the userrw DisplayString .1.3.6.1.4.1.12148.10.8.4.2 |
windChargersErrorTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.8.4.3 |
windChargersErrorEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.8.4.4 |
windChargersErrorValueThe number of failed wind chargers.ro Integer32 .1.3.6.1.4.1.12148.10.8.4.5 |
windChargersErrorMajorAlarmLevelThe major alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.8.4.6 |
windChargersErrorMinorAlarmLevelThe minor alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.8.4.7 |
windChargersNumberOfWindChargersNumber of installed wind chargers.rw Integer32 .1.3.6.1.4.1.12148.10.8.5 |
windChargerTableThis table shows the information of each wind charger installed in the system. SEQUENCE OF WindChargerEntry .1.3.6.1.4.1.12148.10.8.6 |
windChargerEntry WindChargerEntry .1.3.6.1.4.1.12148.10.8.6.1 |
windChargerIndexIndex used for navigating the rows 1..100 of windChargerTable Integer32 .1.3.6.1.4.1.12148.10.8.6.1.1 |
windChargerStatusThe overall status of wind charger.ro Enumeration .1.3.6.1.4.1.12148.10.8.6.1.2 |
windChargerOutputCurrentValueThe output current value of wind charger.ro Integer32 .1.3.6.1.4.1.12148.10.8.6.1.3 |
windChargerInputVoltageValueThe input voltage value of wind charger.ro Integer32 .1.3.6.1.4.1.12148.10.8.6.1.4 |
windChargerTypeType of wind chargerro DisplayString .1.3.6.1.4.1.12148.10.8.6.1.5 |
windChargerHwPartNumberHardware part number of wind chargerro DisplayString .1.3.6.1.4.1.12148.10.8.6.1.6 |
windChargerHwVersionHardware version number of wind chargerro DisplayString .1.3.6.1.4.1.12148.10.8.6.1.7 |
windChargerSwPartNumberPart number of secondary software in wind chargerro DisplayString .1.3.6.1.4.1.12148.10.8.6.1.8 |
windChargerSwVersionVersion number of secondary software in wind chargerro DisplayString .1.3.6.1.4.1.12148.10.8.6.1.9 |
windChargersEnergyLog OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.8.7 |
windChargersEnergyLogAccumulatedThis is the accumulated energy delivered to/from wind chargers.ro Integer32 .1.3.6.1.4.1.12148.10.8.7.1 |
windChargersEnergyLogLastHoursNumberOfEntriesThis is the maximal number of entries stored in wind charger hourly energy log.ro Integer32 .1.3.6.1.4.1.12148.10.8.7.2 |
windChargersEnergyLogLastHoursTableThis table contains hourly energy log of wind chargers. SEQUENCE OF WindChargersEnergyLogLastHoursEntry .1.3.6.1.4.1.12148.10.8.7.3 |
windChargersEnergyLogLastHoursEntry WindChargersEnergyLogLastHoursEntry .1.3.6.1.4.1.12148.10.8.7.3.1 |
windChargersEnergyLogLastHoursIndexIndex used for navigating the rows 1..52 of windChargersEnergyLogLastHoursTable Integer32 .1.3.6.1.4.1.12148.10.8.7.3.1.1 |
windChargersEnergyLogLastHoursValueEnergy value logged every hour.ro Integer32 .1.3.6.1.4.1.12148.10.8.7.3.1.2 |
windChargersEnergyLogLastDaysNumberOfEntriesThis is the maximal number of entries stored in wind charger daily energy log.ro Integer32 .1.3.6.1.4.1.12148.10.8.7.4 |
windChargersEnergyLogLastDaysTableThis table contains daily energy log of wind chargers. SEQUENCE OF WindChargersEnergyLogLastDaysEntry .1.3.6.1.4.1.12148.10.8.7.5 |
windChargersEnergyLogLastDaysEntry WindChargersEnergyLogLastDaysEntry .1.3.6.1.4.1.12148.10.8.7.5.1 |
windChargersEnergyLogLastDaysIndexIndex used for navigating the rows 1..52 of windChargersEnergyLogLastDaysTable Integer32 .1.3.6.1.4.1.12148.10.8.7.5.1.1 |
windChargersEnergyLogLastDaysValueEnergy value logged every day.ro Integer32 .1.3.6.1.4.1.12148.10.8.7.5.1.2 |
windChargersEnergyLogLastWeeksNumberOfEntriesThis is the maximal number of entries stored in wind charger weekly energy log.ro Integer32 .1.3.6.1.4.1.12148.10.8.7.6 |
windChargersEnergyLogLastWeeksTableThis table contains weekly energy log of wind chargers. SEQUENCE OF WindChargersEnergyLogLastWeeksEntry .1.3.6.1.4.1.12148.10.8.7.7 |
windChargersEnergyLogLastWeeksEntry WindChargersEnergyLogLastWeeksEntry .1.3.6.1.4.1.12148.10.8.7.7.1 |
windChargersEnergyLogLastWeeksIndexIndex used for navigating the rows 1..52 of windChargersEnergyLogLastWeekTable Integer32 .1.3.6.1.4.1.12148.10.8.7.7.1.1 |
windChargersEnergyLogLastWeeksValueEnergy value logged every week.ro Integer32 .1.3.6.1.4.1.12148.10.8.7.7.1.2 |
load OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.9 |
loadStatusThe overall status of load subsystem.ro Enumeration .1.3.6.1.4.1.12148.10.9.1 |
loadCurrent OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.9.2 |
loadCurrentStatusThe status of the measured load current.ro Enumeration .1.3.6.1.4.1.12148.10.9.2.1 |
loadCurrentDescriptionA textual description of the load current monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.9.2.2 |
loadCurrentTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.9.2.3 |
loadCurrentAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.9.2.4 |
loadCurrentValueThe value of the measured load current.ro Integer32 .1.3.6.1.4.1.12148.10.9.2.5 |
loadCurrentMajorHighLevelThe major high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.9.2.6 |
loadCurrentMinorHighLevelThe minor high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.9.2.7 |
loadFusesStatusThe overall status of the load fuses.ro Enumeration .1.3.6.1.4.1.12148.10.9.3 |
loadNumberOfGroupsNumber of load groupsrw Integer32 .1.3.6.1.4.1.12148.10.9.4 |
loadGroupTableThis table contains information about load groups. SEQUENCE OF LoadGroupEntry .1.3.6.1.4.1.12148.10.9.5 |
loadGroupEntry LoadGroupEntry .1.3.6.1.4.1.12148.10.9.5.1 |
loadGroupIndexIndex used for navigating the rows 1..8 of loadGroupTable Integer32 .1.3.6.1.4.1.12148.10.9.5.1.1 |
loadGroupStatusThe status of load groupro Enumeration .1.3.6.1.4.1.12148.10.9.5.1.2 |
loadNumberOfLVLDsNumber of LVLDs installed in load groupro Integer32 .1.3.6.1.4.1.12148.10.9.5.1.3 |
loadLVLDTableThis table contains information about LVLDs SEQUENCE OF LoadLVLDEntry .1.3.6.1.4.1.12148.10.9.6 |
loadLVLDEntry LoadLVLDEntry .1.3.6.1.4.1.12148.10.9.6.1 |
loadLVLDIndexIndex used for navigating the rows 1..8 of loadLVLDTable Integer32 .1.3.6.1.4.1.12148.10.9.6.1.1 |
loadLVLDStatusThe status of LVLDro Enumeration .1.3.6.1.4.1.12148.10.9.6.1.2 |
loadLVLDDescriptionA textual description of the LVLD. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.9.6.1.3 |
loadLVLDTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.9.6.1.4 |
loadLVLDEnableThis value once enabled, the alarm condition of the LVLD will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.9.6.1.5 |
loadLVLDValueThe measured value of the LVLD.ro Integer32 .1.3.6.1.4.1.12148.10.9.6.1.6 |
loadLVLDConnectVoltageThe load Contactor's Reconnect Voltagerw Integer32 .1.3.6.1.4.1.12148.10.9.6.1.7 |
loadLVLDDisconnectVoltageThe load Contactor's Disconnect Voltagerw Integer32 .1.3.6.1.4.1.12148.10.9.6.1.8 |
loadFuseTableThis table contains information about load fuse SEQUENCE OF LoadFuseEntry .1.3.6.1.4.1.12148.10.9.7 |
loadFuseEntry LoadFuseEntry .1.3.6.1.4.1.12148.10.9.7.1 |
loadFuseStatusThe status of load fusero Enumeration .1.3.6.1.4.1.12148.10.9.7.1.1 |
loadFuseDescriptionA textual description of the load fuse monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.9.7.1.2 |
loadFuseTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.9.7.1.3 |
loadFuseAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.9.7.1.4 |
loadFuseValueThe measured value of the load fuse.rw Integer32 .1.3.6.1.4.1.12148.10.9.7.1.5 |
loadEnergyLog OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.9.8 |
loadEnergyLogAccumulatedThis is the accumulated energy delivered to load.ro Integer32 .1.3.6.1.4.1.12148.10.9.8.1 |
loadEnergyLogLastHoursNumberOfEntriesThis is the maximal number of entries stored in load hourly energy log.ro Integer32 .1.3.6.1.4.1.12148.10.9.8.2 |
loadEnergyLogLastHoursTable SEQUENCE OF LoadEnergyLogLastHoursEntry .1.3.6.1.4.1.12148.10.9.8.3 |
loadEnergyLogLastHoursEntry LoadEnergyLogLastHoursEntry .1.3.6.1.4.1.12148.10.9.8.3.1 |
loadEnergyLogLastHoursIndexIndex used for navigating the rows 1..52 of loadEnergyLogLastHoursTable Integer32 .1.3.6.1.4.1.12148.10.9.8.3.1.1 |
loadEnergyLogLastHoursValueEnergy value logged every hour.ro Integer32 .1.3.6.1.4.1.12148.10.9.8.3.1.2 |
loadEnergyLogLastDaysNumberOfEntriesThis is the maximal number of entries stored in load daily energy log.ro Integer32 .1.3.6.1.4.1.12148.10.9.8.4 |
loadEnergyLogLastDaysTable SEQUENCE OF LoadEnergyLogLastDaysEntry .1.3.6.1.4.1.12148.10.9.8.5 |
loadEnergyLogLastDaysEntry LoadEnergyLogLastDaysEntry .1.3.6.1.4.1.12148.10.9.8.5.1 |
loadEnergyLogLastDaysIndexIndex used for navigating the rows 1..52 of loadEnergyLogLastDaysTable Integer32 .1.3.6.1.4.1.12148.10.9.8.5.1.1 |
loadEnergyLogLastDaysValueEnergy value logged every day.ro Integer32 .1.3.6.1.4.1.12148.10.9.8.5.1.2 |
loadEnergyLogLastWeeksNumberOfEntriesThis is the maximal number of entries stored in load weekly energy log.ro Integer32 .1.3.6.1.4.1.12148.10.9.8.6 |
loadEnergyLogLastWeeksTable SEQUENCE OF LoadEnergyLogLastWeeksEntry .1.3.6.1.4.1.12148.10.9.8.7 |
loadEnergyLogLastWeeksEntry LoadEnergyLogLastWeeksEntry .1.3.6.1.4.1.12148.10.9.8.7.1 |
loadEnergyLogLastWeeksIndexIndex used for navigating the rows 1..52 of loadEnergyLogLastWeekTable Integer32 .1.3.6.1.4.1.12148.10.9.8.7.1.1 |
loadEnergyLogLastWeeksValueEnergy value logged every week.ro Integer32 .1.3.6.1.4.1.12148.10.9.8.7.1.2 |
battery OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.10 |
batteryStatusA toplevel status for the battery subsystem. The state of this reflects the status of all underlying statuses for the battery. Any change in one of the 'data monitors' in the battery subsystem will propagate up to this status indicator.ro Enumeration .1.3.6.1.4.1.12148.10.10.1 |
batteryDescriptionA descriptive name of the battery installed in the system.rw DisplayString .1.3.6.1.4.1.12148.10.10.2 |
batteryReferenceVoltageThe Voltage at which the DC System float charges. Acts as reference voltage when running temperature compensated charging.rw Integer32 .1.3.6.1.4.1.12148.10.10.3 |
batteryFusesStatusThe state of the battery fuses/breakers can mainly be normal(1) or majorAlarm(3) and some other rarely used values .ro Enumeration .1.3.6.1.4.1.12148.10.10.4 |
batteryVoltage OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.10.5 |
batteryVoltageStatusThe status of the measured battery voltage.ro Enumeration .1.3.6.1.4.1.12148.10.10.5.1 |
batteryVoltageDescriptionA textual description of the battery voltage monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.10.5.2 |
batteryVoltageTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.10.5.3 |
batteryVoltageAlarmEnableThe measured battery voltage alarm enable/disable controlrw Enumeration .1.3.6.1.4.1.12148.10.10.5.4 |
batteryVoltageValueThe value of the measured battery voltage.ro Integer32 .1.3.6.1.4.1.12148.10.10.5.5 |
batteryVoltageMajorHighLevelThe Major High Battery Voltage alarm limit set voltagerw Integer32 .1.3.6.1.4.1.12148.10.10.5.6 |
batteryVoltageMinorHighLevelThe Minor High Battery Voltage alarm limit set voltagerw Integer32 .1.3.6.1.4.1.12148.10.10.5.7 |
batteryVoltageMinorLowLevelThe Minor Low Battery Voltage alarm limit set voltagerw Integer32 .1.3.6.1.4.1.12148.10.10.5.8 |
batteryVoltageMajorLowLevelThe Major Low Battery Voltage alarm limit set voltagerw Integer32 .1.3.6.1.4.1.12148.10.10.5.9 |
batteryCurrents OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.10.6 |
batteryCurrentsStatusThe status of the measured battery currentro Enumeration .1.3.6.1.4.1.12148.10.10.6.1 |
batteryCurrentsDescriptionA textual description of the battery current monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.10.6.2 |
batteryCurrentsTrapRepeatCounterThe number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off.ro Counter32 .1.3.6.1.4.1.12148.10.10.6.3 |
batteryCurrentsAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.10.6.4 |
batteryCurrentsValueThe measured total battery current. This is the sum of all the enabled shunt measurements in the system. Negative battery current indicates discharging of the batteries. Positive battery current indicates charging of the batteries. Note that the units measured may be i Amperes or in Deciamperes depending on global system settingsro Integer32 .1.3.6.1.4.1.12148.10.10.6.5 |
batteryCurrentsMajorHighLevelThe major high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.6.6 |
batteryCurrentsMinorHighLevelThe minor high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.6.7 |
batteryCurrentsMinorLowLevelThe minor low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.6.8 |
batteryCurrentsMajorLowLevelThe major low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.6.9 |
batteryTemperatures OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.10.7 |
batteryTemperaturesStatusThe state of the battery fuses/breakers can be either one of the defined enumerated valuesro Enumeration .1.3.6.1.4.1.12148.10.10.7.1 |
batteryTemperaturesDescriptionA textual description of the battery temperature monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.10.7.2 |
batteryTemperaturesTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.10.7.3 |
batteryTemperaturesAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.10.7.4 |
batteryTemperaturesValueThe highest value of the enabled battery temperature measurements. Depending on the global setting in the Control unit, this value will be presented in Celsius or Fahrenheit.ro Integer32 .1.3.6.1.4.1.12148.10.10.7.5 |
batteryTemperaturesMajorHighLevelThe major high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.7.6 |
batteryTemperaturesMinorHighLevelThe minor high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.7.7 |
batteryTemperaturesMinorLowLevelThe minor low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.7.8 |
batteryTemperaturesMajorLowLevelThe major low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.7.9 |
batteryTimeLeft OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.10.8 |
batteryTimeLeftStatusThe status of the estimated battery remaining backup time.ro Enumeration .1.3.6.1.4.1.12148.10.10.8.1 |
batteryTimeLeftDescriptionA textual description of the battery discharge time monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.10.8.2 |
batteryTimeLeftTrapRepeatCounterThe number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off.ro Counter32 .1.3.6.1.4.1.12148.10.10.8.3 |
batteryTimeLeftAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.10.8.4 |
batteryTimeLeftValueThe estimated value of battery remaining backup time.ro Integer32 .1.3.6.1.4.1.12148.10.10.8.5 |
batteryTimeLeftMinorAlarmLevelThe minor alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.8.6 |
batteryTimeLeftMajorAlarmLevelThe major alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.8.7 |
batteryRemainingCapacity OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.10.9 |
batteryRemainingCapacityStatusThe status of the battery remaining capacity monitor.ro Enumeration .1.3.6.1.4.1.12148.10.10.9.1 |
batteryRemainingCapacityDescriptionA textual description of the battery remaining capacity monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.10.9.2 |
batteryRemainingCapacityTrapRepeatCounterThe number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off.ro Counter32 .1.3.6.1.4.1.12148.10.10.9.3 |
batteryRemainingCapacityAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.10.9.4 |
batteryRemainingCapacityValueBattery remaining capacity (SOC) value estimated from the latest battery test result.ro Integer32 .1.3.6.1.4.1.12148.10.10.9.5 |
batteryRemainingCapacityMinorLowLevelThe minor low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.9.6 |
batteryRemainingCapacityMajorLowLevelThe major low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.9.7 |
batteryUsedCapacity OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.10.10 |
batteryUsedCapacityStatusThe status of the battery used capacity (DoD) monitorro Enumeration .1.3.6.1.4.1.12148.10.10.10.1 |
batteryUsedCapacityDescriptionA textual description of the battery used capacity (DoD) monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.10.10.2 |
batteryUsedCapacityTrapRepeatCounterThe number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off.ro Counter32 .1.3.6.1.4.1.12148.10.10.10.3 |
batteryUsedCapacityAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.10.10.4 |
batteryUsedCapacityValueThis is the estimated battery used capacity (DoD).ro Integer32 .1.3.6.1.4.1.12148.10.10.10.5 |
batteryUsedCapacityMajorAlarmLevelThe major alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.10.6 |
batteryUsedCapacityMinorAlarmLevelThe minor alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.10.7 |
batteryTotalCapacity OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.10.11 |
batteryTotalCapacityStatusThe status of the total capacity monitor.ro Enumeration .1.3.6.1.4.1.12148.10.10.11.1 |
batteryTotalCapacityDescriptionA textual description of the battery total capacity monitor. This is stored in the system controller and can be changed by the userrw DisplayString .1.3.6.1.4.1.12148.10.10.11.2 |
batteryTotalCapacityTrapRepeatCounterThe number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off.ro Counter32 .1.3.6.1.4.1.12148.10.10.11.3 |
batteryTotalCapacityAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.10.11.4 |
batteryTotalCapacityValueThis is the estimated total battery capacity (installed Ah - SoH) value.ro Integer32 .1.3.6.1.4.1.12148.10.10.11.5 |
batteryTotalCapacityMinorLowLevelThe minor low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.11.6 |
batteryTotalCapacityMajorLowLevelThe major low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.11.7 |
batteryQuality OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.10.12 |
batteryQualityStatusThe status of the battery quality (SoH) monitor.ro Enumeration .1.3.6.1.4.1.12148.10.10.12.1 |
batteryQualityDescriptionA textual description of the battery quality (SoH) monitor. This is stored in the system controller and can be changed by the userrw DisplayString .1.3.6.1.4.1.12148.10.10.12.2 |
batteryQualityTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.10.12.3 |
batteryQualityAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.10.12.4 |
batteryQualityValueThe calculated battery quality (SoH) based on the latest battery testro Integer32 .1.3.6.1.4.1.12148.10.10.12.5 |
batteryQualityMinorAlarmLevelThe minor alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.12.6 |
batteryQualityMajorAlarmLevelThe major alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.12.7 |
batteryLVBD OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.10.13 |
batteryLVBDStatusThe Battery Contactor is connected, disconnected, disabled or in any other alarm conditionro Enumeration .1.3.6.1.4.1.12148.10.10.13.1 |
batteryLVBDDescriptionA textual description of the battery LVBD monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.10.13.2 |
batteryLVBDTrapRepeatCounterThe number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off.ro Counter32 .1.3.6.1.4.1.12148.10.10.13.3 |
batteryLVBDEnableThis value once enabled, the alarm condition of the LVBD will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.10.13.4 |
batteryLVBDValueThe measured value of the LVBD.ro Integer32 .1.3.6.1.4.1.12148.10.10.13.5 |
batteryLVBDConnectVoltageThe Battery Contactor's Reconnect Voltagerw Integer32 .1.3.6.1.4.1.12148.10.10.13.6 |
batteryLVBDDisconnectVoltageThe Battery Contactor's Disconnect Voltagerw Integer32 .1.3.6.1.4.1.12148.10.10.13.7 |
batteryChargeCurrentLimit OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.10.14 |
batteryChargeCurrentLimitEnableEnable/disable of the battery charge current limitation feature; 0=disable, 1=enable.rw Enumeration .1.3.6.1.4.1.12148.10.10.14.1 |
batteryChargeCurrentLimitValueBattery charging current limit value. Used only when AC source is mains feed. Note that the units measured may be i Amperes or in Deciamperes depending on global system settingsrw Integer32 .1.3.6.1.4.1.12148.10.10.14.2 |
batteryBoost OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.10.15 |
batteryBoostVoltageThe Voltage at which the DC System boost charges the batteries.rw Integer32 .1.3.6.1.4.1.12148.10.10.15.1 |
batteryBoostCommandThis pushbutton will start or stop a manual battery boost if the system allows it.rw Enumeration .1.3.6.1.4.1.12148.10.10.15.2 |
batteryBoostCurrentThresholdThe boosting will terminate when the charge current drops below the BoostCurrentThreshold limit.rw Integer32 .1.3.6.1.4.1.12148.10.10.15.3 |
batteryBoostManualMaxDurationA protection against overcharging. When running manual boost, the boosting will always terminate at this point.rw Integer32 .1.3.6.1.4.1.12148.10.10.15.4 |
batteryTest OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.10.16 |
batteryTestVoltageThis is the battery test end voltage. The battery test will be terminated when the voltage drops below the end voltage.rw Integer32 .1.3.6.1.4.1.12148.10.10.16.1 |
batteryTestCommandThis pushbutton will start or stop a manual battery test if the system allows it.rw Enumeration .1.3.6.1.4.1.12148.10.10.16.2 |
batteryTestNumberOfResultsThis is the number of valid battery test results stored in controller.ro Integer32 .1.3.6.1.4.1.12148.10.10.16.3 |
batteryTestResultTableThis table contains the battery test results stored in controller. SEQUENCE OF BatteryTestResultEntry .1.3.6.1.4.1.12148.10.10.16.4 |
batteryTestResultEntry BatteryTestResultEntry .1.3.6.1.4.1.12148.10.10.16.4.1 |
batteryTestResultIndexA index pointing to one of ten possible battery test results Integer32 .1.3.6.1.4.1.12148.10.10.16.4.1.1 |
batteryTestResultStartDateTimeThis is the time and date when the test started.ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.12148.10.10.16.4.1.2 |
batteryTestResultDurationThis is the test duration in minutes.ro Integer32 .1.3.6.1.4.1.12148.10.10.16.4.1.3 |
batteryTestResultDischargedThis is the discharged Ah during test.ro Integer32 .1.3.6.1.4.1.12148.10.10.16.4.1.4 |
batteryTestResultQualityThis is the calculated battery quality (SoH)in percentage.ro Integer32 .1.3.6.1.4.1.12148.10.10.16.4.1.5 |
batteryTempComp OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.10.17 |
batteryTempCompEnableEnable (1) or Disable (0) of Battery Temperature Compensated output regulation moderw Enumeration .1.3.6.1.4.1.12148.10.10.17.1 |
batteryBank OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.10.18 |
batteryBankNumberOfBanksNumber of battery banks installed in system.rw Integer32 .1.3.6.1.4.1.12148.10.10.18.1 |
batteryBankTable SEQUENCE OF BatteryBankEntry .1.3.6.1.4.1.12148.10.10.18.2 |
batteryBankEntry BatteryBankEntry .1.3.6.1.4.1.12148.10.10.18.2.1 |
batteryBankIndexIndex used for navigating the rows 1..8 of batteryBankTable Integer32 .1.3.6.1.4.1.12148.10.10.18.2.1.1 |
batteryBankStatusThe overall status of battery bankro Enumeration .1.3.6.1.4.1.12148.10.10.18.2.1.2 |
batteryBankNumberOfTemperaturesNumber of temperature measurements in battery bank.ro Integer32 .1.3.6.1.4.1.12148.10.10.18.2.1.3 |
batteryBankNumberOfCurrentsNumber of current measurements in battery bank.ro Integer32 .1.3.6.1.4.1.12148.10.10.18.2.1.4 |
batteryBankNumberOfFusesNumber of fuses installed in battery bank.ro Integer32 .1.3.6.1.4.1.12148.10.10.18.2.1.5 |
batteryBankTemperatureTable SEQUENCE OF BatteryBankTemperatureEntry .1.3.6.1.4.1.12148.10.10.18.3 |
batteryBankTemperatureEntry BatteryBankTemperatureEntry .1.3.6.1.4.1.12148.10.10.18.3.1 |
batteryTemperatureIndexThis index denotes which row in the temperature input table. The size of the table is defined by the batteryBankNumberOfTemp Integer32 .1.3.6.1.4.1.12148.10.10.18.3.1.1 |
batteryTemperatureStatusThe status of battery temperature monitorro Enumeration .1.3.6.1.4.1.12148.10.10.18.3.1.2 |
batteryTemperatureDescriptionA textual description of the battery temperature monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.10.18.3.1.3 |
batteryTemperatureTrapRepeatCounterThe number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off.ro Counter32 .1.3.6.1.4.1.12148.10.10.18.3.1.4 |
batteryTemperatureAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.10.18.3.1.5 |
batteryTemperatureValueThe measured battery temperature.ro Integer32 .1.3.6.1.4.1.12148.10.10.18.3.1.6 |
batteryTemperatureMajorHighLevelThe major high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.18.3.1.7 |
batteryTemperatureMinorHighLevelThe minor high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.18.3.1.8 |
batteryTemperatureMinorLowLevelThe minor low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.18.3.1.9 |
batteryTemperatureMajorLowLevelThe major low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.18.3.1.10 |
batteryBankCurrentTable SEQUENCE OF BatteryBankCurrentEntry .1.3.6.1.4.1.12148.10.10.18.4 |
batteryBankCurrentEntry BatteryBankCurrentEntry .1.3.6.1.4.1.12148.10.10.18.4.1 |
batteryCurrentIndexThis index denotes which row in the current input table. The size of the table is defined by the system Integer32 .1.3.6.1.4.1.12148.10.10.18.4.1.1 |
batteryCurrentStatusThe status of battery current monitorro Enumeration .1.3.6.1.4.1.12148.10.10.18.4.1.2 |
batteryCurrentDescriptionA textual description of the battery current monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.10.18.4.1.3 |
batteryCurrentTrapRepeatCounterThe number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off.ro Counter32 .1.3.6.1.4.1.12148.10.10.18.4.1.4 |
batteryCurrentAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.10.18.4.1.5 |
batteryCurrentValueThe measured battery currentro Integer32 .1.3.6.1.4.1.12148.10.10.18.4.1.6 |
batteryCurrentMajorHighLevelThe major high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.18.4.1.7 |
batteryCurrentMinorHighLevelThe minor high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.18.4.1.8 |
batteryCurrentMinorLowLevelThe minor low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.18.4.1.9 |
batteryCurrentMajorLowLevelThe major low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.18.4.1.10 |
batteryBankFuseTable SEQUENCE OF BatteryBankFuseEntry .1.3.6.1.4.1.12148.10.10.18.5 |
batteryBankFuseEntry BatteryBankFuseEntry .1.3.6.1.4.1.12148.10.10.18.5.1 |
batteryFuseIndexThis index denotes which row in the fuse table. The size of the table is defined by the system Integer32 .1.3.6.1.4.1.12148.10.10.18.5.1.1 |
batteryFuseStatusThe status of battery fuse monitorro Enumeration .1.3.6.1.4.1.12148.10.10.18.5.1.2 |
batteryFuseDescriptionA textual description of the battery fuse monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.10.18.5.1.3 |
batteryFuseTrapRepeatCounterThe number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes off.ro Counter32 .1.3.6.1.4.1.12148.10.10.18.5.1.4 |
batteryFuseAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.10.18.5.1.5 |
batteryFuseValueThe measured value of battery fuse input.ro Integer32 .1.3.6.1.4.1.12148.10.10.18.5.1.6 |
batteryMonitors OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.10.19 |
batteryMonitorsNumberOfUnitsThe number of battery monitor installed in system.rw Integer32 .1.3.6.1.4.1.12148.10.10.19.1 |
batteryMonitorsTable SEQUENCE OF BatteryMonitorsEntry .1.3.6.1.4.1.12148.10.10.19.2 |
batteryMonitorsEntry BatteryMonitorsEntry .1.3.6.1.4.1.12148.10.10.19.2.1 |
batteryMonitorIndexIndex used for navigating the rows 1..8 of batteryMonitorsTable Integer32 .1.3.6.1.4.1.12148.10.10.19.2.1.1 |
batteryMonitorNumberOfTemperaturesThe number of temperature measurements in battery monitor.ro Integer32 .1.3.6.1.4.1.12148.10.10.19.2.1.2 |
batteryMonitorNumberOfCurrentsThe number of current measurements in battery monitor.ro Integer32 .1.3.6.1.4.1.12148.10.10.19.2.1.3 |
batteryMonitorNumberOfFusesThe number of fuse measurements in battery monitor.ro Integer32 .1.3.6.1.4.1.12148.10.10.19.2.1.4 |
batteryMonitorNumberOfSymmetriesThe number of symmetry measurements in battery monitor.ro Integer32 .1.3.6.1.4.1.12148.10.10.19.2.1.5 |
batteryMonitorTemperatureTable SEQUENCE OF BatteryMonitorTemperatureEntry .1.3.6.1.4.1.12148.10.10.19.3 |
batteryMonitorTemperatureEntry BatteryMonitorTemperatureEntry .1.3.6.1.4.1.12148.10.10.19.3.1 |
batteryMonitorTemperatureIndexThis index denotes which row in the temperature input table. The size of the table is defined by the batteryMonitorNumberOfTemperatures Integer32 .1.3.6.1.4.1.12148.10.10.19.3.1.1 |
batteryMonitorTemperatureStatusThe status of battery temperature monitorro Enumeration .1.3.6.1.4.1.12148.10.10.19.3.1.2 |
batteryMonitorTemperatureDescriptionA textual description of the battery monitor temperature. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.10.19.3.1.3 |
batteryMonitorTemperatureTrapRepeatCounterThe number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.10.19.3.1.4 |
batteryMonitorTemperatureAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.10.19.3.1.5 |
batteryMonitorTemperatureValueThe measured battery temperature in battery monitor.ro Integer32 .1.3.6.1.4.1.12148.10.10.19.3.1.6 |
batteryMonitorTemperatureMajorHighLevelThe major high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.19.3.1.7 |
batteryMonitorTemperatureMinorHighLevelThe minor high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.19.3.1.8 |
batteryMonitorTemperatureMinorLowLevelThe minor low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.19.3.1.9 |
batteryMonitorTemperatureMajorLowLevelThe major low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.19.3.1.10 |
batteryMonitorCurrentTable SEQUENCE OF BatteryMonitorCurrentEntry .1.3.6.1.4.1.12148.10.10.19.4 |
batteryMonitorCurrentEntry BatteryMonitorCurrentEntry .1.3.6.1.4.1.12148.10.10.19.4.1 |
batteryMonitorCurrentIndexThis index denotes which row in the current input table. The size of the table is defined by the batteryMonitorNumberOfCurrents Integer32 .1.3.6.1.4.1.12148.10.10.19.4.1.1 |
batteryMonitorCurrentStatusThe status of battery current monitorro Enumeration .1.3.6.1.4.1.12148.10.10.19.4.1.2 |
batteryMonitorCurrentDescriptionA textual description of the battery monitor current. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.10.19.4.1.3 |
batteryMonitorCurrentTrapRepeatCounterThe number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.10.19.4.1.4 |
batteryMonitorCurrentAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.10.19.4.1.5 |
batteryMonitorCurrentValueThe measured battery current in battery monitor.ro Integer32 .1.3.6.1.4.1.12148.10.10.19.4.1.6 |
batteryMonitorCurrentMajorHighLevelThe major high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.19.4.1.7 |
batteryMonitorCurrentMinorHighLevelThe minor high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.19.4.1.8 |
batteryMonitorCurrentMinorLowLevelThe minor low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.19.4.1.9 |
batteryMonitorCurrentMajorLowLevelThe major low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.19.4.1.10 |
batteryMonitorFuseTable SEQUENCE OF BatteryMonitorFuseEntry .1.3.6.1.4.1.12148.10.10.19.5 |
batteryMonitorFuseEntry BatteryMonitorFuseEntry .1.3.6.1.4.1.12148.10.10.19.5.1 |
batteryMonitorFuseIndexThis index denotes which row in the fuse table. The size of the table is defined by the batteryMonitorNumberOfFuses Integer32 .1.3.6.1.4.1.12148.10.10.19.5.1.1 |
batteryMonitorFuseStatusThe status of battery fuse monitorro Enumeration .1.3.6.1.4.1.12148.10.10.19.5.1.2 |
batteryMonitorFuseDescriptionA textual description of the battery monitor fuse. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.10.19.5.1.3 |
batteryMonitorFuseTrapRepeatCounterThe number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.10.19.5.1.4 |
batteryMonitorFuseAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.10.19.5.1.5 |
batteryMonitorFuseValueThe measured value of battery fuse in battery monitor.ro Integer32 .1.3.6.1.4.1.12148.10.10.19.5.1.6 |
batteryMonitorSymmetryTable SEQUENCE OF BatteryMonitorSymmetryEntry .1.3.6.1.4.1.12148.10.10.19.6 |
batteryMonitorSymmetryEntry BatteryMonitorSymmetryEntry .1.3.6.1.4.1.12148.10.10.19.6.1 |
batteryMonitorSymmetryIndexThis index denotes which row in the symmetry input table. The size of the table is defined by the batteryMonitorNumberOfSymmetries Integer32 .1.3.6.1.4.1.12148.10.10.19.6.1.1 |
batteryMonitorSymmetryStatusThe status of battery symmetry monitorro Enumeration .1.3.6.1.4.1.12148.10.10.19.6.1.2 |
batteryMonitorSymmetryDescriptionA textual description of the battery monitor symmetry. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.10.19.6.1.3 |
batteryMonitorSymmetryTrapRepeatCounterThe number of consecutive times this alam condition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.10.19.6.1.4 |
batteryMonitorSymmetryAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.10.19.6.1.5 |
batteryMonitorSymmetryMeasureValueThe measured battery symmetry voltage in battery monitor.ro Integer32 .1.3.6.1.4.1.12148.10.10.19.6.1.6 |
batteryMonitorSymmetryDeltaValueThe measured battery symmetry delta voltage in battery monitor.ro Integer32 .1.3.6.1.4.1.12148.10.10.19.6.1.7 |
batteryMonitorSymmetryMajorAlarmLevelThe major alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.19.6.1.8 |
batteryMonitorSymmetryMinorAlarmLevelThe minor alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.10.19.6.1.9 |
batteryEnergyLog OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.10.20 |
batteryEnergyLogAccumulatedThis is the accumulated energy delivered to/from battery.ro Integer32 .1.3.6.1.4.1.12148.10.10.20.1 |
batteryEnergyLogLastHoursNumberOfEntriesThis is the maximal number of entries stored in battery hourly energy log.ro Integer32 .1.3.6.1.4.1.12148.10.10.20.2 |
batteryEnergyLogLastHoursTableThis table contains hourly energy log of battery. SEQUENCE OF BatteryEnergyLogLastHoursEntry .1.3.6.1.4.1.12148.10.10.20.3 |
batteryEnergyLogLastHoursEntry BatteryEnergyLogLastHoursEntry .1.3.6.1.4.1.12148.10.10.20.3.1 |
batteryEnergyLogLastHoursIndexIndex used for navigating the rows 1..52 of batteryEnergyLogLastHoursTable Integer32 .1.3.6.1.4.1.12148.10.10.20.3.1.1 |
batteryEnergyLogLastHoursValueEnergy value logged every hour.ro Integer32 .1.3.6.1.4.1.12148.10.10.20.3.1.2 |
batteryEnergyLogLastDaysNumberOfEntriesThis is the maximal number of entries stored in battery daily energy log.ro Integer32 .1.3.6.1.4.1.12148.10.10.20.4 |
batteryEnergyLogLastDaysTableThis table contains daily energy log of battery. SEQUENCE OF BatteryEnergyLogLastDaysEntry .1.3.6.1.4.1.12148.10.10.20.5 |
batteryEnergyLogLastDaysEntry BatteryEnergyLogLastDaysEntry .1.3.6.1.4.1.12148.10.10.20.5.1 |
batteryEnergyLogLastDaysIndexIndex used for navigating the rows 1..52 of batteryEnergyLogLastDaysTable Integer32 .1.3.6.1.4.1.12148.10.10.20.5.1.1 |
batteryEnergyLogLastDaysValueEnergy value logged every day.ro Integer32 .1.3.6.1.4.1.12148.10.10.20.5.1.2 |
batteryEnergyLogLastWeeksNumberOfEntriesThis is the maximal number of entries stored in battery weekly energy log.ro Integer32 .1.3.6.1.4.1.12148.10.10.20.6 |
batteryEnergyLogLastWeeksTableThis table contains weekly energy log of battery. SEQUENCE OF BatteryEnergyLogLastWeeksEntry .1.3.6.1.4.1.12148.10.10.20.7 |
batteryEnergyLogLastWeeksEntry BatteryEnergyLogLastWeeksEntry .1.3.6.1.4.1.12148.10.10.20.7.1 |
batteryEnergyLogLastWeeksIndexIndex used for navigating the rows 1..52 of batteryEnergyLogLastWeekTable Integer32 .1.3.6.1.4.1.12148.10.10.20.7.1.1 |
batteryEnergyLogLastWeeksValueEnergy value logged every week.ro Integer32 .1.3.6.1.4.1.12148.10.10.20.7.1.2 |
batteryCycleLog OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.10.21 |
batteryCycleLogTotalCyclesThis is the total number of battery discharge cycles.ro Integer32 .1.3.6.1.4.1.12148.10.10.21.1 |
batteryCycleLogDaysNumberOfEntriesThis is the maximal number of entries stored in daily battery discharge cycle log.ro Integer32 .1.3.6.1.4.1.12148.10.10.21.2 |
batteryCycleLogDaysTableThis table contains daily battery discharge cycle log. SEQUENCE OF BatteryCycleLogDaysEntry .1.3.6.1.4.1.12148.10.10.21.3 |
batteryCycleLogDaysEntry BatteryCycleLogDaysEntry .1.3.6.1.4.1.12148.10.10.21.3.1 |
batteryCycleLogDaysIndexIndex used for navigating the rows 1..52 of batteryCycleLogLastDaysTable Integer32 .1.3.6.1.4.1.12148.10.10.21.3.1.1 |
batteryCycleLogDaysValueNumber of discharge cycles logged every day.ro Integer32 .1.3.6.1.4.1.12148.10.10.21.3.1.2 |
batteryCycleLogWeeksNumberOfEntriesThis is the maximal number of entries stored in weeky battery discharge cycle log.ro Integer32 .1.3.6.1.4.1.12148.10.10.21.4 |
batteryCycleLogWeeksTableThis table contains weekly battery discharge cycle log. SEQUENCE OF BatteryCycleLogWeeksEntry .1.3.6.1.4.1.12148.10.10.21.5 |
batteryCycleLogWeeksEntry BatteryCycleLogWeeksEntry .1.3.6.1.4.1.12148.10.10.21.5.1 |
batteryCycleLogWeeksIndexIndex used for navigating the rows 1..52 of batteryCycleLogLastWeeksTable Integer32 .1.3.6.1.4.1.12148.10.10.21.5.1.1 |
batteryCycleLogWeeksValueNumber of discharge cycles logged every week.ro Integer32 .1.3.6.1.4.1.12148.10.10.21.5.1.2 |
batteryCycleLogMonthsNumberOfEntriesThis is the maximal number of entries stored in monthly battery discharge cycle log.ro Integer32 .1.3.6.1.4.1.12148.10.10.21.6 |
batteryCycleLogMonthsTableThis table contains monthly battery discharge cycle log. SEQUENCE OF BatteryCycleLogMonthsEntry .1.3.6.1.4.1.12148.10.10.21.7 |
batteryCycleLogMonthsEntry BatteryCycleLogMonthsEntry .1.3.6.1.4.1.12148.10.10.21.7.1 |
batteryCycleLogMonthsIndexIndex used for navigating the rows 1..52 of batteryCycleLogLastMonthTable Integer32 .1.3.6.1.4.1.12148.10.10.21.7.1.1 |
batteryCycleLogMonthsValueNumber of discharge cycles logged every month.ro Integer32 .1.3.6.1.4.1.12148.10.10.21.7.1.2 |
inputs OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.11 |
inputControlUnitsTable SEQUENCE OF InputControlUnitsEntry .1.3.6.1.4.1.12148.10.11.1 |
inputControlUnitsEntry InputControlUnitsEntry .1.3.6.1.4.1.12148.10.11.1.1 |
inputControlUnitIndexIndex used for navigating the rows of inputControlUnitTable The size of the table is defined by the system Integer32 .1.3.6.1.4.1.12148.10.11.1.1.1 |
inputControlUnitNumberOfInputsNumber of programmable inputs available in controller.ro Integer32 .1.3.6.1.4.1.12148.10.11.1.1.2 |
inputControlUnitInputTableThis table contains the status of the programmable inputs for Control Units. SEQUENCE OF InputControlUnitInputEntry .1.3.6.1.4.1.12148.10.11.2 |
inputControlUnitInputEntry InputControlUnitInputEntry .1.3.6.1.4.1.12148.10.11.2.1 |
inputControlUnitInputIndexIndex used for navigating the rows of inputControlUnitInputTable The size of the table is defined by the inputControlUnitNumberOfInputs Integer32 .1.3.6.1.4.1.12148.10.11.2.1.1 |
inputControlUnitInputStatusProgrammable input status.ro Enumeration .1.3.6.1.4.1.12148.10.11.2.1.2 |
inputControlUnitInputDescriptionA textual description of the programmable input. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.11.2.1.3 |
inputControlUnitInputTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.11.2.1.4 |
inputControlUnitInputAlarmEnableThis will enable or disable this inputs Alarm functionality. Setting 'disabled' here will turn off lock the status to 'disabled' staterw Enumeration .1.3.6.1.4.1.12148.10.11.2.1.5 |
inputControlUnitInputValueThe inputs measured Value. Depending on the type of input, this may represent a Voltage, a Temperature, a Current or a Boolean value. Note: This value can only be set for virtual input on SP2 master or Smartpack S. When this value is set to '0', the input is deactivated; When this value is set to '1', the input is activated; if set to any other value, an Inconsistent Value error will be generated.rw Integer32 .1.3.6.1.4.1.12148.10.11.2.1.6 |
inputControlUnitInputConfigurationConfiguration of the input type. Configurations available for different controllers are as follows: SP2 Master(clock, virtual), SP2 Basic(normally open, normally close),Compack(normally open, normallly close, diode matrix, voltage, clock)rw Enumeration .1.3.6.1.4.1.12148.10.11.2.1.7 |
inputIoUnitsTable SEQUENCE OF InputIoUnitsEntry .1.3.6.1.4.1.12148.10.11.3 |
inputIoUnitsEntry InputIoUnitsEntry .1.3.6.1.4.1.12148.10.11.3.1 |
inputIoUnitIndexIndex used for navigating the rows of inputIoUnitsTable The size of the table is defined by the system Integer32 .1.3.6.1.4.1.12148.10.11.3.1.1 |
inputIoUnitNumberOfInputsNumber of programmable inputs available in IO unit.ro Integer32 .1.3.6.1.4.1.12148.10.11.3.1.2 |
inputIoUnitProgInputTableThis table contains the status of the programmable inputs for I/O monitor units. . SEQUENCE OF InputIoUnitProgInputEntry .1.3.6.1.4.1.12148.10.11.4 |
inputIoUnitProgInputEntry InputIoUnitProgInputEntry .1.3.6.1.4.1.12148.10.11.4.1 |
inputIoUnitProgInputIndexThe Index to the Input of the selected I/O monitor unit. Or the input number if you like. Integer32 .1.3.6.1.4.1.12148.10.11.4.1.1 |
inputIoUnitProgInputStatusProgrammable input status.ro Enumeration .1.3.6.1.4.1.12148.10.11.4.1.2 |
inputIoUnitProgInputDescriptionA textual description of the programmable input in IO unit. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.11.4.1.3 |
inputIoUnitProgInputTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.11.4.1.4 |
inputIoUnitProgInputAlarmEnableThis will enable or disable this inputs Alarm functionality. Setting 'disabled' here will turn off lock the status to 'disabled' staterw Enumeration .1.3.6.1.4.1.12148.10.11.4.1.5 |
inputIoUnitProgInputValueThe inputs measured Value. Depending on the type of input, this may represent a Voltage, a Temperature, a Current or a Boolean value.ro Integer32 .1.3.6.1.4.1.12148.10.11.4.1.6 |
inputIoUnitProgInputConfigurationConfiguration of the input type. Configurations available for IO unit are normally open, normally closed, diode matrix, voltage.rw Enumeration .1.3.6.1.4.1.12148.10.11.4.1.7 |
outputs OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.12 |
outputControlUnitTable SEQUENCE OF OutputControlUnitEntry .1.3.6.1.4.1.12148.10.12.1 |
outputControlUnitEntry OutputControlUnitEntry .1.3.6.1.4.1.12148.10.12.1.1 |
outputControlUnitIndexIndex used for navigating the rows of outputControlUnitTable The size of the table is defined by the system Integer32 .1.3.6.1.4.1.12148.10.12.1.1.1 |
outputControlUnitNumberOfOutputsNumber of outputs available in controller.ro Integer32 .1.3.6.1.4.1.12148.10.12.1.1.2 |
outputControlUnitOutputTableThis table contains the status of the outputs for Control Units. SEQUENCE OF OutputControlUnitOutputEntry .1.3.6.1.4.1.12148.10.12.2 |
outputControlUnitOutputEntry OutputControlUnitOutputEntry .1.3.6.1.4.1.12148.10.12.2.1 |
outputControlUnitOutputIndexIndex used for navigating the rows of outputControlUnitoutputTable The size of the table is defined by the outputControlUnitNumberOfOutputs Integer32 .1.3.6.1.4.1.12148.10.12.2.1.1 |
outputControlUnitOutputStatusGeneral output relays may be 'energized' or 'not energized'. 'energized' and 'not energized' correspond to normal and alarm condition respectively for normally activated configuration. Latched contactors may have values 'disconnected' or 'connected'ro Enumeration .1.3.6.1.4.1.12148.10.12.2.1.2 |
outputControlUnitOutputDescriptionA textual description of the output. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.12.2.1.3 |
outputIoUnitTable SEQUENCE OF OutputIoUnitEntry .1.3.6.1.4.1.12148.10.12.3 |
outputIoUnitEntry OutputIoUnitEntry .1.3.6.1.4.1.12148.10.12.3.1 |
outputIoUnitIndexIndex used for navigating the rows of outputIoUnitTable The size of the table is defined by the system Integer32 .1.3.6.1.4.1.12148.10.12.3.1.1 |
outputIoUnitNumberOfOutputsNumber of outputs available in IO unit.ro Integer32 .1.3.6.1.4.1.12148.10.12.3.1.2 |
outputIoUnitOutputTableThis table contains the status of the outputs for IO Units. SEQUENCE OF OutputIoUnitOutputEntry .1.3.6.1.4.1.12148.10.12.4 |
outputIoUnitOutputEntry OutputIoUnitOutputEntry .1.3.6.1.4.1.12148.10.12.4.1 |
outputIoUnitOutputIndexIndex used for navigating the rows of outputIOUnitOutputTable The size of the table is defined by the outputIOUnitNumberOfOutputs Integer32 .1.3.6.1.4.1.12148.10.12.4.1.1 |
outputIoUnitOutputStatusGeneral output relays may be 'energized' or 'not energized'. Latched contactors may have values 'disconnected' or 'connected'ro Enumeration .1.3.6.1.4.1.12148.10.12.4.1.2 |
outputIoUnitOutputDescriptionA textual description of the output in IO unit. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.12.4.1.3 |
controlSystem OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.13 |
controlSystemStatusThe overall status of control system subsystemro Enumeration .1.3.6.1.4.1.12148.10.13.1 |
controlSystemClockThis is the system time.rw DateAndTime .1.3.6.1.4.1.12148.10.13.2 |
controlSystemNumberOfControlUnitsTotal number of controllers (SP2 Basic, Compack, Smartpack S, Smartpack)rw Integer32 .1.3.6.1.4.1.12148.10.13.3 |
snmp OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.13.4 |
snmpSendOffTrapsWhen this is enabled, a trap is sent when a alarm condition goes off .rw Enumeration .1.3.6.1.4.1.12148.10.13.4.1 |
snmpTrapRepeatRateThe time between every repeated trap when an alarm condition is on. To turn repetetive traps off, set to zero. Can be 0 to 1440 minutes i.e 24 hours.rw Integer32 .1.3.6.1.4.1.12148.10.13.4.2 |
snmpHeartBeatTrapRepeatRateThe time between every heartbeat trap when an alarm condition is on. To turn heartbeat traps off, set to zero. Can be 0 to 1440 minutes i.e 24 hours.rw Integer32 .1.3.6.1.4.1.12148.10.13.4.3 |
snmpInhibitTrapsWhen this is enabled, no trap is sent regardless of alarm conditions.rw Enumeration .1.3.6.1.4.1.12148.10.13.4.4 |
controlSystemResetManualAlarmsReset manual alarms and put buzzer into silence.rw Enumeration .1.3.6.1.4.1.12148.10.13.5 |
controlSystemResetNumberOfModulesIf set to '1', the number of modules (rectifier, solar charger, wind charger, control units, etc.) will be reset, and only those modules communicating are counted.rw Enumeration .1.3.6.1.4.1.12148.10.13.6 |
controlSystemIoUnits OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.13.7 |
controlSystemIoUnitsNumberOfUnitsThis is the number of IO units installed in the system.rw Integer32 .1.3.6.1.4.1.12148.10.13.7.1 |
controlSystemIoUnitsTable SEQUENCE OF ControlSystemIoUnitsEntry .1.3.6.1.4.1.12148.10.13.7.2 |
controlSystemIoUnitsEntry ControlSystemIoUnitsEntry .1.3.6.1.4.1.12148.10.13.7.2.1 |
controlSystemIoUnitIndexIndex used for navigating the rows of controlSystemIoUnitTable The size of the table is defined by the system Integer32 .1.3.6.1.4.1.12148.10.13.7.2.1.1 |
controlSystemIoUnitNumberOfTemperaturesNumber of temperature measurements available in IO unitro Integer32 .1.3.6.1.4.1.12148.10.13.7.2.1.2 |
controlSystemIoUnitNumberOfFansNumber of fan measurements available in IO unitro Integer32 .1.3.6.1.4.1.12148.10.13.7.2.1.3 |
controlSystemIoUnitTemperatureTable SEQUENCE OF ControlSystemIoUnitTemperatureEntry .1.3.6.1.4.1.12148.10.13.7.3 |
controlSystemIoUnitTemperatureEntry ControlSystemIoUnitTemperatureEntry .1.3.6.1.4.1.12148.10.13.7.3.1 |
controlSystemIoUnitTemperatureIndexIndex used for navigating the rows of controlSystemIoUnitTemperatureTable The size of the table is defined by the controlSystemIoUnitNumberOfTemperatures Integer32 .1.3.6.1.4.1.12148.10.13.7.3.1.1 |
controlSystemIoUnitTemperatureStatusThe status of temperature monitorro Enumeration .1.3.6.1.4.1.12148.10.13.7.3.1.2 |
controlSystemIoUnitTemperatureDescriptionA textual description of the temperature monitor in control system. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.13.7.3.1.3 |
controlSystemIoUnitTemperatureTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.13.7.3.1.4 |
controlSystemIoUnitTemperatureAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.13.7.3.1.5 |
controlSystemIoUnitTemperatureValueThe measured temperature value.ro Integer32 .1.3.6.1.4.1.12148.10.13.7.3.1.6 |
controlSystemIoUnitTemperatureMajorHighLevelThe major high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.13.7.3.1.7 |
controlSystemIoUnitTemperatureMinorHighLevelThe minor high alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.13.7.3.1.8 |
controlSystemIoUnitTemperatureMinorLowLevelThe minor low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.13.7.3.1.9 |
controlSystemIoUnitTemperatureMajorLowLevelThe major low alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.13.7.3.1.10 |
controlSystemIoUnitFanTable SEQUENCE OF ControlSystemIoUnitFanEntry .1.3.6.1.4.1.12148.10.13.7.4 |
controlSystemIoUnitFanEntry ControlSystemIoUnitFanEntry .1.3.6.1.4.1.12148.10.13.7.4.1 |
controlSystemIoUnitFanIndexIndex used for navigating the rows 1..2 of ioUnitFan Table Integer32 .1.3.6.1.4.1.12148.10.13.7.4.1.1 |
controlSystemIoUnitFanSpeedValueThe measured fan speedro Integer32 .1.3.6.1.4.1.12148.10.13.7.4.1.2 |
controlSystemIoUnitFanSpeedDeviationThe measured fan speed deviationro Integer32 .1.3.6.1.4.1.12148.10.13.7.4.1.3 |
controlSystemIoUnitFanControlFan speed control value in percentagero Integer32 .1.3.6.1.4.1.12148.10.13.7.4.1.4 |
controlSystemInventory OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.13.8 |
controlUnitNumberOfUnitsTotal number of control units installed in system.ro Integer32 .1.3.6.1.4.1.12148.10.13.8.1 |
controlUnitTableA table containing an inventory listing. Each row represent one of the system hardware unit that is connected to the can bus. These units are system controllers, battery monitors, I/O units, AC Mains Monitor boxes and load monitors. Due to the system architechture the tables index are not contiguous. Each unit type har its own address range on the can bus. All unit types except the system controller may contain from 0 to 14 units. The system controlller can never be zero. Then there is no powersystem. SEQUENCE OF ControlUnitEntry .1.3.6.1.4.1.12148.10.13.8.2 |
controlUnitEntryOne row in the table containing all hardware units connected to the canbus. ControlUnitEntry .1.3.6.1.4.1.12148.10.13.8.2.1 |
controlUnitIndexIndex used for navigating the rows of controlUnitTable The size of the table is defined by the controlUnitNumberOfUnits Integer32 .1.3.6.1.4.1.12148.10.13.8.2.1.1 |
controlUnitDescriptionA textual description of the control unitro DisplayString .1.3.6.1.4.1.12148.10.13.8.2.1.2 |
controlUnitStatusThe overall status of the control unit.ro Enumeration .1.3.6.1.4.1.12148.10.13.8.2.1.3 |
controlUnitSerialNumberSerial number of the control unit.ro DisplayString .1.3.6.1.4.1.12148.10.13.8.2.1.4 |
controlUnitHwPartNumberHardware part number of the control unit.ro DisplayString .1.3.6.1.4.1.12148.10.13.8.2.1.5 |
controlUnitHwVersionHardware version of the control unit.ro DisplayString .1.3.6.1.4.1.12148.10.13.8.2.1.6 |
controlUnitSwPartNumberSoftware part number of the control unit.ro DisplayString .1.3.6.1.4.1.12148.10.13.8.2.1.7 |
controlUnitSwVersionSoftware version of the control unit.ro DisplayString .1.3.6.1.4.1.12148.10.13.8.2.1.8 |
currentMonitors OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.13.9 |
currentMonitorsNumberOfUnitsThis is the number of current monitors installed in the system.rw Integer32 .1.3.6.1.4.1.12148.10.13.9.1 |
currentMonitorsTable SEQUENCE OF CurrentMonitorsEntry .1.3.6.1.4.1.12148.10.13.9.2 |
currentMonitorsEntry CurrentMonitorsEntry .1.3.6.1.4.1.12148.10.13.9.2.1 |
currentMonitorIndexIndex used for navigating the rows of currentMonitorsTable The size of the table is defined by the system Integer32 .1.3.6.1.4.1.12148.10.13.9.2.1.1 |
currentMonitorTypeThis shows if the current monitor is configured as standard load monitor (1), load current monitor (2), rectifier current monitor (3), dcdc current monitor (4), solar current monitor (5), wind current monitor (6) or fuel cell current monitor (7).ro Enumeration .1.3.6.1.4.1.12148.10.13.9.2.1.2 |
currentMonitorIdThis is the unit index for each current monitor type.ro Integer32 .1.3.6.1.4.1.12148.10.13.9.2.1.3 |
currentMonitorNumberOfFusesNumber of fuse measurements in current monitor.ro Integer32 .1.3.6.1.4.1.12148.10.13.9.2.1.4 |
currentMonitorNumberOfCurrentsNumber of current measurements in current monitor.ro Integer32 .1.3.6.1.4.1.12148.10.13.9.2.1.5 |
currentMonitorFuseTable SEQUENCE OF CurrentMonitorFuseEntry .1.3.6.1.4.1.12148.10.13.9.3 |
currentMonitorFuseEntry CurrentMonitorFuseEntry .1.3.6.1.4.1.12148.10.13.9.3.1 |
currentMonitorFuseIndexIndex used for navigating the rows of currentMonitorFuseTable The size of the table is defined by the currentMonitorNumberOfFuses Integer32 .1.3.6.1.4.1.12148.10.13.9.3.1.1 |
currentMonitorFuseStatusThe status of fuse in current monitorro Enumeration .1.3.6.1.4.1.12148.10.13.9.3.1.2 |
currentMonitorFuseDescriptionA textual description of the fuse monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.13.9.3.1.3 |
currentMonitorFuseTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.13.9.3.1.4 |
currentMonitorFuseAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.13.9.3.1.5 |
currentMonitorFuseValueThe measured fuse value.ro Integer32 .1.3.6.1.4.1.12148.10.13.9.3.1.6 |
currentMonitorCurrentTable SEQUENCE OF CurrentMonitorCurrentEntry .1.3.6.1.4.1.12148.10.13.9.4 |
currentMonitorCurrentEntry CurrentMonitorCurrentEntry .1.3.6.1.4.1.12148.10.13.9.4.1 |
currentMonitorCurrentIndexIndex used for navigating the rows of currentMonitorCurrentTable The size of the table is defined by the currentMonitorNumberOfCurrents Integer32 .1.3.6.1.4.1.12148.10.13.9.4.1.1 |
currentMonitorCurrentStatusThe status of current in current monitorro Enumeration .1.3.6.1.4.1.12148.10.13.9.4.1.2 |
currentMonitorCurrentDescriptionA textual description of the current monitor. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.13.9.4.1.3 |
currentMonitorCurrentTrapRepeatCounterThe number of consecutive times this alamcondition has been transmitted in a trap. When trap repetition is enabled, this counter increments every time this trap is repeated. The counter is automatically set to zero when the alarm condition is reset and the alarm goes offro Counter32 .1.3.6.1.4.1.12148.10.13.9.4.1.4 |
currentMonitorCurrentAlarmEnableThis value once enabled, the alarm condition of the monitor will be reported.rw Enumeration .1.3.6.1.4.1.12148.10.13.9.4.1.5 |
currentMonitorCurrentValueThe measured current value.ro Integer32 .1.3.6.1.4.1.12148.10.13.9.4.1.6 |
currentMonitorCurrentMajorAlarmLevelThe major alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.13.9.4.1.7 |
currentMonitorCurrentMinorAlarmLevelThe minor alarm limitrw Integer32 .1.3.6.1.4.1.12148.10.13.9.4.1.8 |
currentMonitorEnergyLogAccumulatedTableThis table contains the accumulated energy consumption measured in current monitor SEQUENCE OF CurrentMonitorEnergyLogAccumulatedEntry .1.3.6.1.4.1.12148.10.13.9.5 |
currentMonitorEnergyLogAccumulatedEntry CurrentMonitorEnergyLogAccumulatedEntry .1.3.6.1.4.1.12148.10.13.9.5.1 |
currentMonitorEnergyLogAccumulatedThe accumulated energy consumption valuero Integer32 .1.3.6.1.4.1.12148.10.13.9.5.1.1 |
currentMonitorEnergyLogLastHoursNumberOfEntriesThis is the maximal number of entries stored in hourly energy logro Integer32 .1.3.6.1.4.1.12148.10.13.9.6 |
currentMonitorEnergyLogLastHoursTableThis table contains energy consumption values logged every hour in current monitor. SEQUENCE OF CurrentMonitorEnergyLogLastHoursEntry .1.3.6.1.4.1.12148.10.13.9.7 |
currentMonitorEnergyLogLastHoursEntry CurrentMonitorEnergyLogLastHoursEntry .1.3.6.1.4.1.12148.10.13.9.7.1 |
currentMonitorEnergyLogLastHoursIndexIndex used for navigating the rows 1..52 of currentMonitorEnergyLogLastHoursTable Integer32 .1.3.6.1.4.1.12148.10.13.9.7.1.1 |
currentMonitorEnergyLogLastHoursValueEnergy consumption value logged every hour in current monitor.ro Integer32 .1.3.6.1.4.1.12148.10.13.9.7.1.2 |
currentMonitorEnergyLogLastDaysNumberOfEntriesThis is the maximal number of entries stored in daily energy logro Integer32 .1.3.6.1.4.1.12148.10.13.9.8 |
currentMonitorEnergyLogLastDaysTableThis table contains energy consumption values logged every day in current monitor. SEQUENCE OF CurrentMonitorEnergyLogLastDaysEntry .1.3.6.1.4.1.12148.10.13.9.9 |
currentMonitorEnergyLogLastDaysEntry CurrentMonitorEnergyLogLastDaysEntry .1.3.6.1.4.1.12148.10.13.9.9.1 |
currentMonitorEnergyLogLastDaysIndexIndex used for navigating the rows 1..52 of currentMonitorEnergyLogLastDaysTable Integer32 .1.3.6.1.4.1.12148.10.13.9.9.1.1 |
currentMonitorEnergyLogLastDaysValueEnergy consumption value logged every day in current monitor.ro Integer32 .1.3.6.1.4.1.12148.10.13.9.9.1.2 |
currentMonitorEnergyLogLastWeeksNumberOfEntriesThis is the maximal number of entries stored in weekly energy logro Integer32 .1.3.6.1.4.1.12148.10.13.9.10 |
currentMonitorEnergyLogLastWeeksTableThis table contains energy consumption values logged every week in current monitor. SEQUENCE OF CurrentMonitorEnergyLogLastWeeksEntry .1.3.6.1.4.1.12148.10.13.9.11 |
currentMonitorEnergyLogLastWeeksEntry CurrentMonitorEnergyLogLastWeeksEntry .1.3.6.1.4.1.12148.10.13.9.11.1 |
currentMonitorEnergyLogLastWeeksIndexIndex used for navigating the rows 1..52 of currentMonitorEnergyLogLastWeekTable Integer32 .1.3.6.1.4.1.12148.10.13.9.11.1.1 |
currentMonitorEnergyLogLastWeeksValueEnergy consumption value logged every week in current monitor.ro Integer32 .1.3.6.1.4.1.12148.10.13.9.11.1.2 |
alarmGroups OBJECT IDENTIFIER .1.3.6.1.4.1.12148.10.14 |
alarmGroupTable SEQUENCE OF AlarmGroupEntry .1.3.6.1.4.1.12148.10.14.1 |
alarmGroupEntry AlarmGroupEntry .1.3.6.1.4.1.12148.10.14.1.1 |
alarmGroupIndexIndex used for navigating the rows 1..49 of alarmGroupTable Integer32 .1.3.6.1.4.1.12148.10.14.1.1.1 |
alarmGroupStatusThe status of alarm groupro Enumeration .1.3.6.1.4.1.12148.10.14.1.1.2 |
alarmGroupDescriptionA textual description of the alarm group. This is stored in the system controller and can be changed by the user.rw DisplayString .1.3.6.1.4.1.12148.10.14.1.1.3 |