SONUS-SYSTEM-TIMING-MIB
AI MIB Summary
The SONUS-SYSTEM-TIMING-MIB enables monitoring and configuration of synchronization sources, clock states, and timing parameters for Sonus network elements to ensure precise frequency and phase alignment across the infrastructure.
The MIB Module for System Timing management.
Main OID:
sonusSystemTimingMIB.1.3.6.1.4.1.2879.2.1.3
78
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
78 total| Object Name |
|---|
sonusSystemTimingMIBThe MIB Module for System Timing management. MODULE-IDENTITY .1.3.6.1.4.1.2879.2.1.3 |
sonusSystemTimingMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2879.2.1.3.1 |
sonusStShelfAdmnTable SEQUENCE OF SonusStShelfAdmnEntry .1.3.6.1.4.1.2879.2.1.3.1.1 |
sonusStShelfAdmnEntry SonusStShelfAdmnEntry .1.3.6.1.4.1.2879.2.1.3.1.1.1 |
sonusStShelfAdmnShelfIndexIdentifies the target shelf within the node.ro SonusShelfIndex (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.1.1.1.1 |
sonusStShelfAdmnFailoverGuardTimeIndicates how long a timing source can be faulting before switchover to another source is initiatedrw Integer32 .1.3.6.1.4.1.2879.2.1.3.1.1.1.2 |
sonusStShelfAdmnRecoveryGuardTimeIndicates how long a timing source must be valid for, after it has faulted, before it will be considered valid again.rw Integer32 .1.3.6.1.4.1.2879.2.1.3.1.1.1.3 |
sonusStShelfAdmnTransmitRemoteAlarmNot Supportedrw Enumeration .1.3.6.1.4.1.2879.2.1.3.1.1.1.4 |
sonusStShelfAdmnRevertRefSwitchingIf enabled, then a timing source which has failed, but then becomes valid again, will be reconsidered for use. If disabled, then once a timing source fails, it will never be automatically reconsidered for use. To use the source again requires manual user intervention.rw Enumeration .1.3.6.1.4.1.2879.2.1.3.1.1.1.5 |
sonusStShelfAdmnRevertMtaSwitchingIf enabled, then an MTA which is hot-inserted will automatically be brought on line and made available for use. If disabled, then an MTA which is hot-inserted will require manual user configuration before being available for use.rw Enumeration .1.3.6.1.4.1.2879.2.1.3.1.1.1.6 |
sonusStShelfAdmnRevertInsertDelayMTA warm-up period. When an MTA is hot-inserted, the card will be allowed to warm up and stabilize for this amount of time before being put back into service. This warm-up period is also used during cold start of a shelf.rw Integer32 .1.3.6.1.4.1.2879.2.1.3.1.1.1.7 |
sonusStShelfAdmnFreeRunAlarmNot Supportedrw Enumeration .1.3.6.1.4.1.2879.2.1.3.1.1.1.8 |
sonusStShelfAdmnTimingSourceActionResequence will cause the timing sequence list to be re-evaluated. This may cause the current active timing source to change.rw Enumeration .1.3.6.1.4.1.2879.2.1.3.1.1.1.9 |
sonusStShelfAdmnRowStatusThis object indicates the row status for this table.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.2879.2.1.3.1.1.1.10 |
sonusStShelfAdmnSourceReconfigAlgThis object indicates which algorithm should be used to select timing sources for use as System Synchronized sources. Selecting Ordered_list causes sources to be selected for use in strict numerical order, as assigned by default or by the operator. Selecting SSM_Quality will cause sources to be selected based upon the quality level of the timing source, as indicated by the sources Synchronized Status Messages. Do not select SSM_Quality unless all configured timing sources support SSM'srw Enumeration .1.3.6.1.4.1.2879.2.1.3.1.1.1.11 |
sonusStShelfAdmnMtaSourceAffinityThis object works in conjunction with the Source Reconfiguration Algorithm object. If sticky is selected, System Timing Manager will exhaust oll timing sources on an MTA at all quality levels before selecting a timing source on the alternate MTA. If none is selected, timing sources will be chosen based on stratum quality only, reguardless of which MTA is providing the source. This object has no effect when the Source Reconfiguration Algorithm is set to Ordered_list.rw Enumeration .1.3.6.1.4.1.2879.2.1.3.1.1.1.12 |
sonusStShelfStatTable SEQUENCE OF SonusStShelfStatEntry .1.3.6.1.4.1.2879.2.1.3.1.2 |
sonusStShelfStatEntry SonusStShelfStatEntry .1.3.6.1.4.1.2879.2.1.3.1.2.1 |
sonusStShelfStatShelfIndexro SonusShelfIndex (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.1.2.1.1 |
sonusStShelfStatActiveMtaSlotIdentifies which MTA is providing the System Synchronized Timing signal.ro SonusMtaSlotIndex (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.1.2.1.2 |
sonusStShelfStatActiveSourceIdentifies what timing source the active MTA is using to provide System Synchronized Timing.ro SonusTimingSource (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.1.2.1.3 |
sonusStMtaAdmnTable SEQUENCE OF SonusStMtaAdmnEntry .1.3.6.1.4.1.2879.2.1.3.1.3 |
sonusStMtaAdmnEntry SonusStMtaAdmnEntry .1.3.6.1.4.1.2879.2.1.3.1.3.1 |
sonusStMtaAdmnShelfIndexIdentifies the target shelf within the node.ro SonusShelfIndex (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.1.3.1.1 |
sonusStMtaAdmnMtaSlotIndexIdentifies the target slot within the shelf.ro SonusMtaSlotIndex (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.1.3.1.2 |
sonusStMtaAdmnStateIf enabled, the MTA can participate in system timing. If disabled, then it will be removed from service and not allowed to participate. All timing sequence entries bound to this node will be marked as out of service. In a non-redundant configuration the MTA admin state cannot be disabled.rw SonusAdminState (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.1.3.1.3 |
sonusStMtaAdmnLineEncodingSelect AMI or B8ZS line coding for BITS LIU. Select HDB3 for SETS LIUrw Enumeration .1.3.6.1.4.1.2879.2.1.3.1.3.1.4 |
sonusStMtaAdmnSsmChannelBitMTA 20, E1 support only. Identifies which of the additional spare bits, embedded within the framing pattern, contains the SSM channelrw Enumeration .1.3.6.1.4.1.2879.2.1.3.1.3.1.5 |
sonusStMtaAdmnFramerModeSelect ESF or D4/SF for BITS framer. ESF should be selected if B8ZS has been selected for the line encoding. D4/SF should be selected if AMI has been selected for the line encoding. Select MF or MF-CRC4 for SETS framerrw Enumeration .1.3.6.1.4.1.2879.2.1.3.1.3.1.6 |
sonusStMtaAdmnFramerTransmitYellowAlarmNot supportedrw Enumeration .1.3.6.1.4.1.2879.2.1.3.1.3.1.7 |
sonusStMtaAdmnLiuTransmitAllOnesNot supportedrw Enumeration .1.3.6.1.4.1.2879.2.1.3.1.3.1.8 |
sonusStMtaAdmnActionSelecting AVAILABLE will cause the MTA to be moved from the Out-Of-Service state to the Available-For-Use state. This command is necessary to manually make an MTA available for use after it has failed, and revertive MTA switching is not enabled. This may cause the current active timing source to change.rw Enumeration .1.3.6.1.4.1.2879.2.1.3.1.3.1.9 |
sonusStMtaAdmnRowStatusThis object indicates the row status for this table.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.2879.2.1.3.1.3.1.10 |
sonusStMtaStatTable SEQUENCE OF SonusStMtaStatEntry .1.3.6.1.4.1.2879.2.1.3.1.4 |
sonusStMtaStatEntry SonusStMtaStatEntry .1.3.6.1.4.1.2879.2.1.3.1.4.1 |
sonusStMtaStatShelfIndexro SonusShelfIndex (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.1.4.1.1 |
sonusStMtaStatMtaSlotIndexro SonusMtaSlotIndex (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.1.4.1.2 |
sonusStMtaStatOperStatIndicates the operational status of the MTAro Enumeration .1.3.6.1.4.1.2879.2.1.3.1.4.1.3 |
sonusStMtaStatMtaHwDescDescription of the MTA hardware in the form of 'hwtype_hwRev'.ro DisplayString .1.3.6.1.4.1.2879.2.1.3.1.4.1.4 |
sonusStMtaStatMtaHwTypeDescription of the MTA hardware Type only. Entry 5+6 obsolete entry 4.ro HwTypeID (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.1.4.1.5 |
sonusStMtaStatMtaHwTypeRevDescription of the MTA hardware type revision. Entry 5+6 obsolete entry 4.ro Integer32 .1.3.6.1.4.1.2879.2.1.3.1.4.1.6 |
sonusStMtaStatMtaSerialNumIdentifies the serial number of the server module. This is the serial number assigned to the mta module in manufacturing.ro DisplayString .1.3.6.1.4.1.2879.2.1.3.1.4.1.7 |
sonusStMtaStatMtaPartNumIdentifies the part number of the server module. This is the part number assigned to the mta module in manufacturing.ro DisplayString .1.3.6.1.4.1.2879.2.1.3.1.4.1.8 |
sonusStTimingSourceTable SEQUENCE OF SonusStTimingSourceEntry .1.3.6.1.4.1.2879.2.1.3.1.5 |
sonusStTimingSourceEntry SonusStTimingSourceEntry .1.3.6.1.4.1.2879.2.1.3.1.5.1 |
sonusStTimingSourceShelfIndexrw SonusShelfIndex (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.1.5.1.1 |
sonusStTimingSourceMtaSlotIndexIndicates which MTA this timing node is bound to.rw Integer32 .1.3.6.1.4.1.2879.2.1.3.1.5.1.2 |
sonusStTimingSourceIndicates which physical timing source is bound to this node. External BITS sources are used by MTA 10's, in T1 based chassis'. External SETS sources are used by MTA 2X's, in E1 based chassis'. REFCLK's are based upon timing recovered from a CNS or PNS Server card. HOLDOVER mimics the last known good source before it failed. OSCILLATOR is used when no other valid sources exist on the currently active MTA.rw SonusTimingSource (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.1.5.1.3 |
sonusStTimingSourceStateIf enabled, the source can participate in system timing. If disabled, then it will be removed from service and not be allowed to participate.rw SonusAdminState (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.1.5.1.4 |
sonusStTimingSourceSequenceNumThe timing sequence number is automatically generatedrw Integer32 .1.3.6.1.4.1.2879.2.1.3.1.5.1.5 |
sonusStTimingSourceActionSelecting AVAILABLE will cause the timing source to be moved from the Out-Of-Service state to the Available-For-Use state. This command is necessary to manually make a source available for use after it has failed, and revertive source switching is not enabled. This may cause the current active timing source to change.rw Enumeration .1.3.6.1.4.1.2879.2.1.3.1.5.1.6 |
sonusStTimingSourceRowStatusThis object indicates the row status for this table.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.2879.2.1.3.1.5.1.7 |
sonusStTimingSourceStatTable SEQUENCE OF SonusStTimingSourceStatEntry .1.3.6.1.4.1.2879.2.1.3.1.6 |
sonusStTimingSourceStatEntry SonusStTimingSourceStatEntry .1.3.6.1.4.1.2879.2.1.3.1.6.1 |
sonusStTimingSourceStatShelfIndexIndicates shelf.ro SonusShelfIndex (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.1.6.1.1 |
sonusStTimingSourceStatMtaSlotIndexIndicates which MTA this timing node is bound to.ro SonusMtaSlotIndex (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.1.6.1.2 |
sonusStTimingSourceStatIndicates the physical timing sourcero SonusTimingSource (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.1.6.1.3 |
sonusStTimingSourceStatStateIndicates the current overall state of the timing source, including the hardware state, adminitrative mode and shelf configurationro Enumeration .1.3.6.1.4.1.2879.2.1.3.1.6.1.4 |
sonusStTimingSourceStatTraceabilityIndicates the Quality Level of the System Synchronized Timing Sourcero Enumeration .1.3.6.1.4.1.2879.2.1.3.1.6.1.5 |
sonusStTimingSourceStatLineStateIndicates the current physical status of the timing sourcero Enumeration .1.3.6.1.4.1.2879.2.1.3.1.6.1.6 |
sonusStChannelBindingTableThis table describes how derived timing sources should be mapped to the MTA hardware SEQUENCE OF SonusStChannelBindingEntry .1.3.6.1.4.1.2879.2.1.3.1.7 |
sonusStChannelBindingEntry SonusStChannelBindingEntry .1.3.6.1.4.1.2879.2.1.3.1.7.1 |
sonusStChannelBindingShelfIndexro SonusShelfIndex (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.1.7.1.1 |
sonusStChannelBindingSlotIndexServer slot number to provide a recovered clock source. The same server can be configured to provide both possible recovered clocks as long as different channels(spans) are selected, and the REFCLK each is bound to differsro SonusSlotIndex (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.1.7.1.2 |
sonusStChannelBindingChannelT1/E1 span or OC12 port number to provide the recovered clock source. T1 span range is 1-12(CNS10), 1-28(CNS30), E1 span range is 1-8(CNS20), OC12 port number(PNS20) is 1 only.ro Integer32 .1.3.6.1.4.1.2879.2.1.3.1.7.1.3 |
sonusStChannelBindingRefClkBackplane signal the recovered clock source should be bound to. Each REFCLK must only be bound to a single Server slot/span.ro Enumeration .1.3.6.1.4.1.2879.2.1.3.1.7.1.4 |
sonusStChannelBindingRowStatusThis object indicates the row status for this table.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.2879.2.1.3.1.7.1.5 |
sonusSystemTimingMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.2879.2.1.3.2 |
sonusSystemTimingMIBNotificationsPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.2879.2.1.3.2.0 |
sonusSystemTimingActiveFailedNotificationThis trap indicates that the currently active System Timing clock source has failed. NOTIFICATION-TYPE .1.3.6.1.4.1.2879.2.1.3.2.0.1 |
sonusSystemTimingActiveSwitchoverNotificationThis trap indicates that the active System Timing clock source has been switched to another source. NOTIFICATION-TYPE .1.3.6.1.4.1.2879.2.1.3.2.0.2 |
sonusSystemTimingOscillatorActiveNotificationThis trap indicates that all external sources of System Timing have failed and that the current source of timing is the MTA's internal oscillator. NOTIFICATION-TYPE .1.3.6.1.4.1.2879.2.1.3.2.0.3 |
sonusSystemTimingMTAFailedNotificationThis trap indicates that the MTA indicated has failed or been removed from the shelf. NOTIFICATION-TYPE .1.3.6.1.4.1.2879.2.1.3.2.0.4 |
sonusSystemTimingMTAOperationalNotificationThis trap indicates that the specified MTA is now operational. NOTIFICATION-TYPE .1.3.6.1.4.1.2879.2.1.3.2.0.6 |
sonusSystemTimingMTATotalFailureNotificationThis trap indicates that no MTA's are available for use to provide System Timing. They have either failed, been removed from service or been removed from the shelf. The shelf is no longer capable of being properly timed. Downstream Shelves or other equipment connected to this shelf's MITDC(Marlin Inter-chassis Timing Daisy Chain) may be affected. NOTIFICATION-TYPE .1.3.6.1.4.1.2879.2.1.3.2.0.7 |
sonusSystemTimingMIBNotificationsObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2879.2.1.3.2.1 |
sonusTimingSourcero SonusTimingSource (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.2.1.1 |
sonusTimingSource2ro SonusEventString (SONUS-TC) .1.3.6.1.4.1.2879.2.1.3.2.1.2 |