Home/Catalog/SONUS-SS7-SERVICES-MIB

SONUS-SS7-SERVICES-MIB

The MIB Module for SS7 Gateway and SS7 Node Configuration.
Main OID:
sonusSs7ServicesMIB.1.3.6.1.4.1.2879.2.5.3
241
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

241 total
Object Name
sonusSs7ServicesMIBThe MIB Module for SS7 Gateway and SS7 Node Configuration.
MODULE-IDENTITY
.1.3.6.1.4.1.2879.2.5.3
sonusSs7ServicesMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2879.2.5.3.1
sonusSs7Gateway
OBJECT IDENTIFIER
.1.3.6.1.4.1.2879.2.5.3.1.1
sonusSs7GatewayNextIndexThe next valid index to use when creating an entry in the sonusSs7GatewayTable.ro
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.1.1
sonusSs7GatewayTableThis table specifies the SS7 Gateway list for the GSX9000 node.
SEQUENCE OF SonusSs7GatewayEntry
.1.3.6.1.4.1.2879.2.5.3.1.1.2
sonusSs7GatewayEntry
SonusSs7GatewayEntry
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1
sonusSs7GatewayIndexIdentifies the target SS7 Gateway entry.ro
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.1
sonusSs7GatewayStateThe administrative state of this SS7 Gateway entry.rw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.2
sonusSs7GatewayNameThe name of this SS7 Gateway instance.rw
SonusName (SONUS-TC)
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.3
sonusSs7GatewaySocketTypeIndicates the type of socket interface used by the GSX9000 node for connections to the SS7 Gateway platform.rw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.4
sonusSs7GatewayActiveHostThis status value has been replaced by sonusSs7GatewayNextHost and sonusSs7GatewaySelectHost.rodeprecated
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.5
sonusSs7GatewayPriHostNameThe host name of the primary link to the SS7 Gateway platform.rw
DisplayString
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.6
sonusSs7GatewayPriHostIpaddrSpecifies the IP Address of the primary link to the SS7 Gateway platform.rw
IpAddress
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.7
sonusSs7GatewayPriHostModeSpecifies the service mode of the primary link to the SS7 Gateway platform.rw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.8
sonusSs7GatewayPriHostOosDelayTimerThis element is used to delay the action of taking the primary host link out of service for a specified number of minutes.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.9
sonusSs7GatewaySecHostNameThe host name of the secondary link to the SS7 Gateway platform.rw
DisplayString
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.10
sonusSs7GatewaySecHostIpaddrSpecifies the IP Address of the secondary link to the SS7 Gateway platform.rw
IpAddress
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.11
sonusSs7GatewaySecHostModeSpecifies the service mode of the secondary link to the SS7 Gateway platform.rw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.12
sonusSs7GatewaySecHostOosDelayTimerThis element is used to delay the action of taking the secondary host link out of service for a specified number of minutes.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.13
sonusSs7GatewayRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.14
sonusSs7GatewayPriAltHostIpaddrSpecifies the alternate IP Address of the primary link to the SS7 Gateway platform.rw
IpAddress
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.15
sonusSs7GatewaySecAltHostIpaddrSpecifies the alternate IP Address of the secondary link to the SS7 Gateway platform.rw
IpAddress
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.16
sonusSs7GatewayGwTypeGateway type is identified by the gateway protocol it usesrw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.17
sonusSs7GatewayServerTcpPortTCP port for the server of TALI connectionrw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.18
sonusSs7GatewayClientTcpPortTCP port for the client of TALI connectionrw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.19
sonusSs7GatewayPriTaliTrafficControlControl the ss7 traffic on the primary TALI connectionrw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.20
sonusSs7GatewayPriAltTaliTrafficControlControl the ss7 traffic on the primary TALI connectionrw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.21
sonusSs7GatewaySecTaliTrafficControlControl the ss7 traffic on the secondary TALI connectionrw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.22
sonusSs7GatewaySecAltTaliTrafficControlControl the ss7 traffic on the secondary TALI connectionrw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.23
sonusSs7GatewayTimerTaliT1Send a TALI-TEST upon the expiry of T1 in millisecond.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.24
sonusSs7GatewayTimerTaliT2Guard timer in millisecond for the return of TALI-ALLO or TALI-PROH in response to a TALI-TEST sent earlier.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.25
sonusSs7GatewayTimerTaliT3T3 in millisecond reprsents how long the near end can continue to process received messages after sending TALI-PROH.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.26
sonusSs7GatewayTimerTaliT4Send a TALI-MONI upon the expiry of T4 in millisecond.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.27
sonusSs7GatewayTaliSs7TypeSS7 protocol types used over TALIrw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.28
sonusSs7GatewaySlsBitsThe number of SLS bits to userw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.29
sonusSs7GatewayTaliIsupNormalizationISUP message format over TALI -- normalized or rawrw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.30
sonusSs7GatewayTaliPstnPresentationISUP types over TALIrw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.31
sonusSs7GatewayTaliGroupCodeGroup Code in ASCIIrw
DisplayString
.1.3.6.1.4.1.2879.2.5.3.1.1.2.1.32
sonusSs7GatewayStatusTableStatus Table of the SS7 Gateway for the GSX9000 node.
SEQUENCE OF SonusSs7GatewayStatusEntry
.1.3.6.1.4.1.2879.2.5.3.1.1.3
sonusSs7GatewayStatusEntryList of SS7 Gateway status elements.
SonusSs7GatewayStatusEntry
.1.3.6.1.4.1.2879.2.5.3.1.1.3.1
sonusSs7GatewayStatusIndexIdentifies the SS7 Gateway status entry.ro
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.1.3.1.1
sonusSs7GatewayNextHostIndicates which host link connection to the SS7 Gateway is next to be selected. If there is none, then this element is set to none.ro
SonusSs7GatewayLinkSelection
.1.3.6.1.4.1.2879.2.5.3.1.1.3.1.2
sonusSs7GatewaySelectHostIndicates which host link connection to the SS7 Gateway is selected to be tried. If there is none, then this element is set to none.ro
SonusSs7GatewayLinkSelection
.1.3.6.1.4.1.2879.2.5.3.1.1.3.1.3
sonusSs7GatewayPriTaliConnStateTALI state of the primary connection for this SS7 gateway.ro
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.3.1.4
sonusSs7GatewaySecTaliConnStateTALI state of the secondary connection for this SS7 gateway.ro
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.3.1.5
sonusSs7GatewayPriAltTaliConnStateTALI state of the primary alt connection for this SS7 gateway.ro
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.3.1.6
sonusSs7GatewaySecAltTaliConnStateTALI state of the secondary alt connection for this SS7 gateway.ro
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.3.1.7
sonusSs7GatewayPriNearEndTaliVersionTALI protocol version at the near end of the pri conncectionro
DisplayString
.1.3.6.1.4.1.2879.2.5.3.1.1.3.1.8
sonusSs7GatewayPriFarEndTaliVersionTALI protocol version at the far end of the pri connectionro
DisplayString
.1.3.6.1.4.1.2879.2.5.3.1.1.3.1.9
sonusSs7GatewayPriAltNearEndTaliVersionTALI protocol version at the near end of the pri-alt conn.ro
DisplayString
.1.3.6.1.4.1.2879.2.5.3.1.1.3.1.10
sonusSs7GatewayPriAltFarEndTaliVersionTALI protocol version at the far end of the pri-alt connectionro
DisplayString
.1.3.6.1.4.1.2879.2.5.3.1.1.3.1.11
sonusSs7GatewaySecNearEndTaliVersionTALI protocol version at the near end of the sec conncectionro
DisplayString
.1.3.6.1.4.1.2879.2.5.3.1.1.3.1.12
sonusSs7GatewaySecFarEndTaliVersionTALI protocol version at the far end of the sec connectionro
DisplayString
.1.3.6.1.4.1.2879.2.5.3.1.1.3.1.13
sonusSs7GatewaySecAltNearEndTaliVersionTALI protocol version at the near end of the sec-alt conn.ro
DisplayString
.1.3.6.1.4.1.2879.2.5.3.1.1.3.1.14
sonusSs7GatewaySecAltFarEndTaliVersionTALI protocol version at the far end of the sec-alt connectionro
DisplayString
.1.3.6.1.4.1.2879.2.5.3.1.1.3.1.15
sonusSs7GatewayPSStatusTableStatus Table of the SS7 Gateway of a PRIMARY or SECONDARY for the GSX9000 node.
SEQUENCE OF SonusSs7GatewayPSStatusEntry
.1.3.6.1.4.1.2879.2.5.3.1.1.4
sonusSs7GatewayPSStatusEntryList of SS7 Gateway status elements.
SonusSs7GatewayPSStatusEntry
.1.3.6.1.4.1.2879.2.5.3.1.1.4.1
sonusSs7GatewayPSStatusIndexIdentifies the SS7 Gateway status entry.ro
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.1.4.1.1
sonusSs7GatewayPSStatusPSIndexIdentifies the SS7 Gateway link status entry.ro
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.4.1.2
sonusSs7GatewayPSStatusPrimaryCEIdentifies the link Primary CE value.ro
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.1.4.1.3
sonusSs7GatewayLinkStatusTableLink Status Table of a SS7 Gateway for the GSX9000 node.
SEQUENCE OF SonusSs7GatewayLinkStatusEntry
.1.3.6.1.4.1.2879.2.5.3.1.1.5
sonusSs7GatewayLinkStatusEntryList of SS7 Gateway Link Status elements.
SonusSs7GatewayLinkStatusEntry
.1.3.6.1.4.1.2879.2.5.3.1.1.5.1
sonusSs7GatewayStatusLinkIndexIdentifies the SS7 Gateway status link entry gateway index.ro
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.1.5.1.1
sonusSs7GatewayStatusLinkPSIndexIdentifies the SS7 Gateway status link entry primary or secondary index.ro
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.5.1.2
sonusSs7GatewayStatusLinkHostIndexIdentifies the SS7 Gateway host status link entry index.ro
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.1.5.1.3
sonusSs7GatewayStatusHostNameThe host name of the Link link to the SS7 Gateway platform.ro
DisplayString
.1.3.6.1.4.1.2879.2.5.3.1.1.5.1.4
sonusSs7GatewayStatusHostIpaddrSpecifies the IP Address of the link to the SS7 Gateway platform.ro
IpAddress
.1.3.6.1.4.1.2879.2.5.3.1.1.5.1.5
sonusSs7GatewayStatusHostStateThe state of host link to the SS7 Gateway platform.ro
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.5.1.6
sonusSs7GatewayStatusHostCEThe CE of host link to the SS7 Gateway platform.ro
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.1.5.1.7
sonusSs7NodeStatusTableStatus Table of the SS7 Node for the GSX9000 node.
SEQUENCE OF SonusSs7NodeStatusEntry
.1.3.6.1.4.1.2879.2.5.3.1.1.6
sonusSs7NodeStatusEntryList of SS7 Node status elements.
SonusSs7NodeStatusEntry
.1.3.6.1.4.1.2879.2.5.3.1.1.6.1
sonusSs7NodeStatusIndexIdentifies the SS7 Node status entry.ro
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.1.6.1.1
sonusSs7NodeStatIsupSpecifies the operating status of the ISUP service within this SS7 Node.ro
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.6.1.2
sonusSs7NodeStatMtpSpecifies the current MTP status for this SS7 Node.ro
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.1.6.1.3
sonusSs7Node
OBJECT IDENTIFIER
.1.3.6.1.4.1.2879.2.5.3.1.2
sonusSs7NodeNextIndexThe next valid index to use when creating an entry in the sonusSs7NodeTable.ro
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.1
sonusSs7NodeTableThis table specifies the SS7 Node list for the GSX9000 node.
SEQUENCE OF SonusSs7NodeEntry
.1.3.6.1.4.1.2879.2.5.3.1.2.2
sonusSs7NodeEntry
SonusSs7NodeEntry
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1
sonusSs7NodeIndexIdentifies the target SS7 Node entry.ro
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.1
sonusSs7NodeStateThe administrative state of this SS7 Node entry.rw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.2
sonusSs7NodeNameThe name of this SS7 Node instance.rw
SonusName (SONUS-TC)
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.3
sonusSs7NodePointCodeThe SS7 point code assigned to this SS7 Node entry.rw
PointCode (SONUS-TC)
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.4
sonusSs7NodeServicesThe type of SS7 services (ISUP, TCAP, or both) supported by this SS7 Node entry. As of GSX release 3.02.00, isupOnly is now the only vaild option for this entry.rw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.5
sonusSs7NodeProtocolThe SS7 protocol type supported by this SS7 Node entry.rw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.6
sonusSs7NodeTcapSsnIf Tcap is supported by this SS7 Node, specifies the Sub System Number for this node entry. This object is obsoleted as of GSX release 3.02.00.rwobsolete
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.7
sonusSs7NodeIsupStatusThis status value has been replaced by sonusSs7NodeStatIsuprodeprecated
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.8
sonusSs7NodeTcapStatusSpecifies the operating status of the TCAP service within this SS7 Node. This object is obsoleted as of GSX release 3.02.00.roobsolete
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.9
sonusSs7NodeMtpStatusThis status value has been replaced by sonusSs7NodeStatMtprodeprecated
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.10
sonusSs7NodeGatewayAssignmentThe name of the SS7 Gateway to which this SS7 Node is assigned.rw
DisplayString
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.11
sonusSs7NodeNativePointCodeThe native point code of the SS7 node. e.g. For ITU the point code is in 3 bit 8 bit 3 bit format adding up to 14 bits whereas ANSI uses a 8bit 8bit 8bit format adding up to 24 bits.ro
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.12
sonusSs7NodeModeSpecifies the service mode for this SS7 Node.rw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.13
sonusSs7NodeConnCntrlSpecifies when the Node will establish an ISUP connection with the SS7 Gateway. This parameter is used to minimize unnecessary connections to the SS7 Gateway for ISUP services, allowing the GSX to only establish the ISUP connections that are required by ISUP circuits on a particular shelf. When set to always, the ISUP service connection will be established when the node is enabled. When set to asNeeded, the ISUP service connection will be established only if there are ISUP circuits assigned to this node. This parameter only applies to ISUP service registration.rw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.14
sonusSs7NodeRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.15
sonusSs7NodeStdPointCodeOctet string of the point code. This gives the actual representation the user entered.rw
SonusPointCode (SONUS-TC)
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.16
sonusSs7NodePointCodeSizeIndicates the total number of bits in the point code.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.17
sonusSs7NodePointCodeFormatTypeThe Point Code format type being defined.rw
SonusPointCodeFormat (SONUS-TC)
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.18
sonusSs7NodeServerProtocolThe interface used between the SS7 gateway and the SS7 client on the GSX9000rw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.19
sonusSs7NodeHandShakeIntervalHandShake interval between the client and the server in seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.20
sonusSs7NodeTimerT1The Timer T1 could be changed from its default using this entry. The valid ranges are 4 - 15 seconds for ANSI and 15 - 60 Seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.21
sonusSs7NodeTimerT2The Timer T2 could be changed from its default using this entry. The valid value for ITU is 3 Minutes. This timer has no relevence in the ANSI network.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.22
sonusSs7NodeTimerT3The T3 timer is started on receipt of an Overload message in the ITU network. This has no relevence in the ANSI network. The valid ITU recommended value is 120 Secondsrw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.23
sonusSs7NodeTimerT4The Timer T4 could be changed from its default using this entry.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.24
sonusSs7NodeTimerT5The T5 Timer is started when the release message is sent. The valid values as per the specifications are 60 seconds for the ANSI and 300 to 900 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.25
sonusSs7NodeTimerT6The timer T6 is started when the suspend message is received. The valid range for this timer is 1 to 120 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.26
sonusSs7NodeTimerT7The Timer T7 could be changed from its default using this entry.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.27
sonusSs7NodeTimerT8The T8 timer is timer to be started with continuity check has been indicated in the IAM. The valid range is 10 to 15 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.28
sonusSs7NodeTimerT9The Timer T9 started when outgoing international exchange recieves an ACM. The valid range is 120 to 240 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.29
sonusSs7NodeTimerT10The Timer T10 is started when the last digit is recived in interworking situations. This timer has no relevence to ANSI.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.30
sonusSs7NodeTimerT11The Timer T11 is started when the latest address message is received in interworking situations. The valid range is 15 to 20 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.31
sonusSs7NodeTimerT12The Timer T12 is started when a blocking message is sent. The valid ranges are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.32
sonusSs7NodeTimerT13The Timer T13 is started when the initial blocking messge is sent. The valid value for ANSI is 60 seconds and for ITU is between 300 and 900 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.33
sonusSs7NodeTimerT14The Timer T14 is started when an unblocking message is sent. The valid values are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITUrw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.34
sonusSs7NodeTimerT15The Timer T15 is started when the initial unblocking message is sent. The valid values are 60 seconds for ANSI and 300 to 900 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.35
sonusSs7NodeTimerT16The Timer T16 is started when the reset circuit is started which was not due to expiry of T5. The valid ranges are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.36
sonusSs7NodeTimerT17The Timer T17 is started when initial reset message is sent. The valid values are 60 seconds for ANSI and 300 to 900 for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.37
sonusSs7NodeTimerT18The Timer T18 is started when circuit group blocking message is sent. The valid values are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.38
sonusSs7NodeTimerT19The Timer T19 is started when initial group blocking message is sent. The valid values are 60 seconds for ANSI and 300 to 900 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.39
sonusSs7NodeTimerT20The Timer T20 is started when group unblocking message is sent. The valid ranges are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.40
sonusSs7NodeTimerT21The Timer T21 is started when initial group blocking message is sent. The valid values are 60 seconds for ANSI and 300 to 900 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.41
sonusSs7NodeTimerT22The Timer T22 is started when circuit group reset message is sent. The valid values are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.42
sonusSs7NodeTimerT23The Timer T23 is started when initial group reset message is sent. The valid values are 60 seconds for the ANSI and 300 to 900 seconds for the ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.43
sonusSs7NodeTimerT24The Timer T24 is started when check tone is sent. The value is less than 2 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.44
sonusSs7NodeTimerT25The Timer T25 is started when initial continuity check failure is detected. The range is 1 to 10 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.45
sonusSs7NodeTimerT26The Timer T26 is started when a second or subsequent continuity failure is detected. The valid value are 60 to 180 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.46
sonusSs7NodeTimerT27The Timer T27 is started when a continuity fail message is recieved. The valid values are more than 180 seconds for ANSI and 240 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.47
sonusSs7NodeTimerT28The Timer T28 is started when Circuit Query Message is sent. The valid value is 10 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.48
sonusSs7NodeTimerT29The Timer T29 is started when Congestion indication is received when T29 is not running. The valid range is 300 to 600 milli second. This timer has no relevence for ANSI.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.49
sonusSs7NodeTimerT30The Timer T30 is stared when congestion indication is recieved when T29 is not running. The valid range is 5 to 10 seconds for the ITU. This timer has no relevence under ANSI.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.50
sonusSs7NodeTimerT31The Timer T31 is started on release of ISUP signalling connection based on CO SCCP. The value should be set to greater than 360 secondsrw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.51
sonusSs7NodeTimerT32The Timer T32 is started when the first end-to-end message is recived. Under ANSI this timer is started after the response to such a message is sent. The valid values are 3 to 5 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.52
sonusSs7NodeTimerT33The Timer T33 is started when Information Request Message is sent. The valid range is 12 to 15 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.53
sonusSs7NodeTimerT34The Timer T34 is started when Loop Back Acknowledgement is sent under ANSI. The Timer T34 is started when segmentation is received for IAM, ACM, CPG, ANM or CON under ITU. The valid range for ANSI is 10 to 15 seconds. The valid range for ITU is 2 to 4 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.54
sonusSs7NodeTimerT35The Timer T35 is started when the last digit recieved is not an ST digit or the fixed number of digits have been recieved. This procedure is only valid for overlap hence ITU. This timer has no relevence in ANSI.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.55
sonusSs7NodeTimerT36The Timer T36 is started when IAM is recived with a segmentation indication for ANSI. This timer is started when transit or incoming international exchange recieves Continuity check request message. The valid range for ANSI is 2 to 4 seconds and 10 to 15 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.56
sonusSs7NodeTimerT37The Timer T37 is started when User Part Availability test is started under ANSI. This timer is started when a request for and Echo control device is sent to another exchange under ITU. The valid value for ANSI is 30 seconds and for ITU is 2 to 4 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.57
sonusSs7NodeTimerT38The Timer T38 is started when a suspend message is sent to the preceding switch. This timer is only relevent under ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.58
sonusSs7NodeTimerT39The Timer T39 is started when MCID request is sent. It is only relevent in the ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.59
sonusSs7NodeTimerT40The Timer T40 could be changed from its default using this entry.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.60
sonusSs7NodeTimerTAccAutomatic Congestion Control Timer as per ANSI T1.113.4 - 1995. The value of the timer is 5 Seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.61
sonusSs7NodeTimerTCcrContinuity Check Request Timer. The value As per ANSI T1.113.4 - 1995 is 2 Seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.62
sonusSs7NodeTimerTCcrrContinuity Check Failed Recived. The value as per ANSI T1.113.4 - 1995 is 20 Seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.63
sonusSs7NodeTimerTCgbTimer started on recipt of a Circuit Group Block Message. The value as per ANSI T1.113.4 - 1995 is 5 Seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.64
sonusSs7NodeTimerTCraTimer started when Circuit Reservation Acknowledgment is sent. The time value as per ANSI T1.113.4 - 1995 is 20 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.65
sonusSs7NodeTimerTCrmThis timer is started when the circuit reservation message is sent. The value as per ANSI T1.113.4 - 1995 is 3 - 4 Seconds. The default is set to 4 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.66
sonusSs7NodeTimerTCvtThe Timer T CVT is started when the Circuit Validation Test message is sent. This message is only valid for ANSI.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.67
sonusSs7NodeTimerTExmThe Timer Exm,d is started when IAM is sent to the succeeding network. This timer has no relevence in the ITU. This timer is in millisecondsrw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.68
sonusSs7NodeTimerTGrsThis timer is started when a circuit group reset message is received. This timer is only relevent in the ANSI network.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.69
sonusSs7NodeTimerTHgaThis timer is started on recognition of carrier loss. It is only relevent in ANSI network. The valid range is 0 to 300 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.70
sonusSs7NodeTimerTScgaThis timer is started when initial demand continuity check fails in the SCGA group. The valid range for this timer is 0 to 120 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.71
sonusSs7NodeTimerTScgadThis timer is started failure of demand continuity check in the SCGA group.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.72
sonusSs7NodeApplProfileNameThe SS7 Node Profile to be applied to the node. The values here are a snap shot only and might have changed since they were set.rw
DisplayString
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.73
sonusSs7NodeNetworkIndThe setting of the Network Indicator used for this SS7 Node entry.rw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.74
sonusSs7NodeSlsBitsThe number of SLS bits to userw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.75
sonusSs7NodeTimerTAThe Bellcore specific timer TA is the guard timer on outgoing SS7 circuit before idling. The value of this timer is 0 to 1000 milliseconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.76
sonusSs7NodeTimerTBlomThe Bellcore specific timer TBlom is started when blocking a circuit due to a BLO, and after any call is released; used to notify maintenance.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.77
sonusSs7NodeTimerTCotdThe Bellcore specific timer TCOTd is started when sending IAM requesting continuity check. The value of this timer is in milliseconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.78
sonusSs7NodeTimerTCotlThe Bellcore specific timer TCOTl is started when receiving second COT coded failed, awaiting receipt of CCR.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.79
sonusSs7NodeTimerTSusThe Bellcore specific timer TSUS is started when a SUS message is sent by the terminating switch, awaiting called party off-hook or REL.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.2.2.1.80
sonusSs7NodeProfile
OBJECT IDENTIFIER
.1.3.6.1.4.1.2879.2.5.3.1.3
sonusSs7NodeProfileNextIndexThe next valid index to use when creating an entry in the sonusSs7NodeProfileTable.ro
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.1
sonusSs7NodeProfileTableThis table specifies the SS7 Node Profile list for the GSX9000 node.
SEQUENCE OF SonusSs7NodeProfileEntry
.1.3.6.1.4.1.2879.2.5.3.1.3.2
sonusSs7NodeProfileEntry
SonusSs7NodeProfileEntry
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1
sonusSs7NodeProfileIndexIdentifies the SS7 Node Profile entryro
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.1
sonusSs7NodeProfileNameThe name of the Node Profilerw
SonusName (SONUS-TC)
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.2
sonusSs7PointCodeSizeIndicates the total number of bits in the point code.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.3
sonusSs7PointCodeFormatTypeThe Point Code format type being defined.rw
SonusPointCodeFormat (SONUS-TC)
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.4
sonusSs7ServerProtocolThe interface used between the SS7 gateway and the SS7 client on the GSX9000rw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.5
sonusSs7HandShakeIntervalHandShake interval between the client and the server in seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.6
sonusSs7TimerT1The Timer T1 could be changed from its default using this entry. The valid ranges are 4 - 15 seconds for ANSI and 15 - 60 Seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.7
sonusSs7TimerT2The Timer T2 could be changed from its default using this entry. The valid value for ITU is 3 Minutes. This timer has no relevence in the ANSI network.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.8
sonusSs7TimerT3The T3 timer is started on receipt of an Overload message in the ITU network. This has no relevence in the ANSI network. The valid ITU recommended value is 120 Secondsrw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.9
sonusSs7TimerT4The Timer T4 could be changed from its default using this entry.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.10
sonusSs7TimerT5The T5 Timer is started when the release message is sent. The valid values as per the specifications are 60 seconds for the ANSI and 300 to 900 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.11
sonusSs7TimerT6The timer T6 is started when the suspend message is received. The valid range for this timer is 10 to 32 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.12
sonusSs7TimerT7The Timer T7 could be changed from its default using this entry.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.13
sonusSs7TimerT8The T8 timer is timer to be started with continuity check has been indicated in the IAM. The valid range is 10 to 15 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.14
sonusSs7TimerT9The Timer T9 started when outgoing international exchange recieves an ACM. The valid range is 120 to 240 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.15
sonusSs7TimerT10The Timer T10 is started when the last digit is recived in interworking situations. This timer has no relevence to ANSI.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.16
sonusSs7TimerT11The Timer T11 is started when the latest address message is received in interworking situations. The valid range is 15 to 20 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.17
sonusSs7TimerT12The Timer T12 is started when a blocking message is sent. The valid ranges are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.18
sonusSs7TimerT13The Timer T13 is started when the initial blocking messge is sent. The valid value for ANSI is 60 seconds and for ITU is between 300 and 900 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.19
sonusSs7TimerT14The Timer T14 is started when an unblocking message is sent. The valid values are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITUrw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.20
sonusSs7TimerT15The Timer T15 is started when the initial unblocking message is sent. The valid values are 60 seconds for ANSI and 300 to 900 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.21
sonusSs7TimerT16The Timer T16 is started when the reset circuit is started which was not due to expiry of T5. The valid ranges are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.22
sonusSs7TimerT17The Timer T17 is started when initial reset message is sent. The valid values are 60 seconds for ANSI and 300 to 900 for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.23
sonusSs7TimerT18The Timer T18 is started when circuit group blocking message is sent. The valid values are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.24
sonusSs7TimerT19The Timer T19 is started when initial group blocking message is sent. The valid values are 60 seconds for ANSI and 300 to 900 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.25
sonusSs7TimerT20The Timer T20 is started when group unblocking message is sent. The valid ranges are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.26
sonusSs7TimerT21The Timer T21 is started when initial group blocking message is sent. The valid values are 60 seconds for ANSI and 300 to 900 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.27
sonusSs7TimerT22The Timer T22 is started when circuit group reset message is sent. The valid values are 4 to 15 seconds for ANSI and 15 to 60 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.28
sonusSs7TimerT23The Timer T23 is started when initial group reset message is sent. The valid values are 60 seconds for the ANSI and 300 to 900 seconds for the ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.29
sonusSs7TimerT24The Timer T24 is started when check tone is sent. The value is less than 2 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.30
sonusSs7TimerT25The Timer T25 is started when initial continuity check failure is detected. The range is 1 to 10 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.31
sonusSs7TimerT26The Timer T26 is started when a second or subsequent continuity failure is detected. The valid value are 60 to 180 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.32
sonusSs7TimerT27The Timer T27 is started when a continuity fail message is recieved. The valid values are more than 180 seconds for ANSI and 240 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.33
sonusSs7TimerT28The Timer T28 is started when Circuit Query Message is sent. The valid value is 10 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.34
sonusSs7TimerT29The Timer T29 is started when Congestion indication is received when T29 is not running. The valid range is 300 to 600 milli second. This timer has no relevence for ANSI.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.35
sonusSs7TimerT30The Timer T30 is stared when congestion indication is recieved when T29 is not running. The valid range is 5 to 10 seconds for the ITU. This timer has no relevence under ANSI.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.36
sonusSs7TimerT31The Timer T31 is started on release of ISUP signalling connection based on CO SCCP. The value should be set to greater than 360 secondsrw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.37
sonusSs7TimerT32The Timer T32 is started when the first end-to-end message is recived. Under ANSI this timer is started after the response to such a message is sent. The valid values are 3 to 5 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.38
sonusSs7TimerT33The Timer T33 is started when Information Request Message is sent. The valid range is 12 to 15 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.39
sonusSs7TimerT34The Timer T34 is started when Loop Back Acknowledgement is sent under ANSI. The Timer T34 is started when segmentation is received for IAM, ACM, CPG, ANM or CON under ITU. The valid range for ANSI is 10 to 15 seconds. The valid range for ITU is 2 to 4 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.40
sonusSs7TimerT35The Timer T35 is started when the last digit recieved is not an ST digit or the fixed number of digits have been recieved. This procedure is only valid for overlap hence ITU. This timer has no relevence in ANSI.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.41
sonusSs7TimerT36The Timer T36 is started when IAM is recived with a segmentation indication for ANSI. This timer is started when transit or incoming international exchange recieves Continuity check request message. The valid range for ANSI is 2 to 4 seconds and 10 to 15 seconds for ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.42
sonusSs7TimerT37The Timer T37 is started when User Part Availability test is started under ANSI. This timer is started when a request for and Echo control device is sent to another exchange under ITU. The valid value for ANSI is 30 seconds and for ITU is 2 to 4 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.43
sonusSs7TimerT38The Timer T38 is started when a suspend message is sent to the preceding switch. This timer is only relevent under ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.44
sonusSs7TimerT39The Timer T39 is started when MCID request is sent. It is only relevent in the ITU.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.45
sonusSs7TimerT40The Timer T40 could be changed from its default using this entry.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.46
sonusSs7TimerTAccAutomatic Congestion Control Timer as per ANSI T1.113.4 - 1995. The value of the timer is 5 Seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.47
sonusSs7TimerTCcrContinuity Check Request Timer. The value As per ANSI T1.113.4 - 1995 is 2 Seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.48
sonusSs7TimerTCcrrContinuity Check Failed Recived. The value as per ANSI T1.113.4 - 1995 is 20 Seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.49
sonusSs7TimerTCgbTimer started on recipt of a Circuit Group Block Message. The value as per ANSI T1.113.4 - 1995 is 5 Seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.50
sonusSs7TimerTCraTimer started when Circuit Reservation Acknowledgment is sent. The time value as per ANSI T1.113.4 - 1995 is 20 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.51
sonusSs7TimerTCrmThis timer is started when the circuit reservation message is sent. The value as per ANSI T1.113.4 - 1995 is 3 - 4 Seconds. The default is set to 4 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.52
sonusSs7TimerTCvtThe Timer T CVT is started when the Circuit Validation Test message is sent. This message is only valid for ANSI.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.53
sonusSs7TimerTExmThe Timer Exm,d is started when IAM is sent to the succeeding network. This timer has no relevence in the ITU. This timer is in milliseconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.54
sonusSs7TimerTGrsThis timer is started when a circuit group reset message is received. This timer is only relevent in the ANSI network.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.55
sonusSs7TimerTHgaThis timer is started on recognition of carrier loss. It is only relevent in ANSI network. The valid range is 0 to 300 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.56
sonusSs7TimerTScgaThis timer is started when initial demand continuity check fails in the SCGA group. The valid range for this timer is 0 to 120 seconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.57
sonusSs7TimerTScgadThis timer is started failure of demand continuity check in the SCGA group.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.58
sonusSs7NodeProfileStateThe administrative state of this object.rw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.59
sonusSs7NodeProfileRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.60
sonusSs7NodeProfileNetworkIndThe setting of the Network Indicator used for this SS7 Node entry.rw
Enumeration
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.61
sonusSs7SlsBitsThe number of SLS bits to userw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.62
sonusSs7TimerTAThe Bellcore specific timer TA is started when a RLC message is sent by the switch. The value of this timer is 0 to 1000 milliseconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.63
sonusSs7TimerTBlomThe Bellcore specific timer TBlom is started when blocking a circuit due to a BLO, and after any call is released; used to notify maintenance.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.64
sonusSs7TimerTCotdThe Bellcore specific timer TCOTd is started when sending IAM requesting continuity check. The value of this timer is in milliseconds.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.65
sonusSs7TimerTCotlThe Bellcore specific timer TCOTl is started when receiving second COT coded failed, awaiting receipt of CCR.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.66
sonusSs7TimerTSusThe Bellcore specific timer TSUS is started when a SUS message is sent by the terminating switch, awaiting called party off-hook or REL.rw
Integer32
.1.3.6.1.4.1.2879.2.5.3.1.3.2.1.67
sonusSs7ServicesMIBNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.2879.2.5.3.2
sonusSs7ServicesMIBNotificationsPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.2879.2.5.3.2.0
sonusSs7NodeConnectionEstablishedNotificationThis trap indicates that a connection has been established to the specified SS7 gateway. Information provided by this trap includes the name of the connected SS7 node, the name of the SS7 gateway on which the node resides, and the type of SS7 service that has been established (ISUP or TCAP).
NOTIFICATION-TYPE
.1.3.6.1.4.1.2879.2.5.3.2.0.1
sonusSs7NodeConnectionFailedNotificationThis trap indicates that an established connection to an SS7 gateway has failed. Information provided by this trap includes the name of the failed SS7 node, the name of the SS7 gateway on which the node resides, the type of SS7 service affected by this failure, and the reason why the connection has failed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2879.2.5.3.2.0.2
sonusSs7NodeConnectionStateChangeNotificationThis trap indicates that an established connection to an SS7 gateway has changed state. Information provided by this trap includes the name of the affected SS7 node, the name of the SS7 gateway on which the node resides, the type of SS7 service affected by this failure, the new state of the node, and the reason for the state change.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2879.2.5.3.2.0.3
sonusSs7NodeMtpStateChangeNotificationThis trap indicates that a MTP state change event has been received from the SS7 gateway, affecting the specified destination (or remote) point code (DPC). Information provided by this trap includes the name of the affected SS7 node, the name of the SS7 gateway on which the node resides, the updated MTP state, and the DPC affected by this event.
NOTIFICATION-TYPE
.1.3.6.1.4.1.2879.2.5.3.2.0.4
sonusSs7ServicesMIBNotificationsObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2879.2.5.3.2.1
sonusSs7NodeServiceTypeThe type of service supported by this SS7 node connection (ISUP or TCAP).ro
DisplayString
.1.3.6.1.4.1.2879.2.5.3.2.1.1
sonusSs7NodeStateChangeReasonThe reason why this SS7 node connection has changed state.ro
DisplayString
.1.3.6.1.4.1.2879.2.5.3.2.1.2
sonusSs7NodeCurrentStateThe current state of this SS7 node connection.ro
Enumeration
.1.3.6.1.4.1.2879.2.5.3.2.1.3
sonusSs7NodeAffectedPointCodeThe SS7 point code affected by this MTP state change.ro
PointCode (SONUS-TC)
.1.3.6.1.4.1.2879.2.5.3.2.1.4
SONUS-SS7-SERVICES-MIB - SNMP MIB Reference | MIBs Explorer