SONUS-SIP-SIGNALLING-MIB
AI MIB Summary
The SONUS-SIP-SIGNALLING-MIB enables monitoring and management of Session Initiation Protocol (SIP) signaling ports on Sonus network equipment, specifically tracking call session states, port availability, and signaling traffic statistics for VoIP infrastructure.
The MIB Module for SIP IP Call Signal Port Management.
Main OID:
sonusSipSignallingMIB.1.3.6.1.4.1.2879.2.6.7
55
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
55 total| Object Name |
|---|
sonusSipSignallingMIBThe MIB Module for SIP IP Call Signal Port Management. MODULE-IDENTITY .1.3.6.1.4.1.2879.2.6.7 |
sonusSipSignallingMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2879.2.6.7.1 |
sonusSipSigTimerObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2879.2.6.7.1.1 |
sonusSipSigTimerT1This is the SIP protocol retransmission timer T1 (in milliseconds). This value applies to all future SIP calls.rw Integer32 .1.3.6.1.4.1.2879.2.6.7.1.1.1 |
sonusSipSigTimerT2This is the SIP protocol retransmission timer T2 (in milliseconds). This value applies to all future SIP calls.rw Integer32 .1.3.6.1.4.1.2879.2.6.7.1.1.2 |
sonusSipSigTimerSessionKeepaliveThis is the SIP protocol session keep-alive timer (in seconds). This value applies to all future SIP calls. when it is set to 0 keepalive is turned offrw Integer32 .1.3.6.1.4.1.2879.2.6.7.1.1.3 |
sonusSipSigRetryObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2879.2.6.7.1.2 |
sonusSipSigNumOfRetryThis is the number of retransmission for SIP message. This value applies to all future SIP calls.rw Integer32 .1.3.6.1.4.1.2879.2.6.7.1.2.1 |
sonusSipSigInviteRetryThis is the number of retransmission for INVITE. This value applies to all future SIP calls.rw Integer32 .1.3.6.1.4.1.2879.2.6.7.1.2.2 |
sonusSipSigPortTableTable of SIP Signalling Port configurations. Limit of two ports. SEQUENCE OF SonusSipSigPortEntry .1.3.6.1.4.1.2879.2.6.7.1.3 |
sonusSipSigPortEntrySIP Signalling Port configuration. SonusSipSigPortEntry .1.3.6.1.4.1.2879.2.6.7.1.3.1 |
sonusSipSigPortIndexIdentifies the Signal Listen Port entry.ro Integer32 .1.3.6.1.4.1.2879.2.6.7.1.3.1.1 |
sonusSipSigPortIpAddressIP Address of the Sip Signalling Port - mandatory parameterrw IpAddress .1.3.6.1.4.1.2879.2.6.7.1.3.1.2 |
sonusSipSigPortNumUDP port number of SIP Signalling Port (default is 5060).rw Integer32 .1.3.6.1.4.1.2879.2.6.7.1.3.1.3 |
sonusSipSigPortInterfaceThe interface type of SIP Call Signal Port. 'mgtnif' routes traffic over the gateway Managment ports. 'nif' routes traffic over one of the gateway PNS ports.rw Enumeration .1.3.6.1.4.1.2879.2.6.7.1.3.1.4 |
sonusSipSigPortRoleRole of the Sip Call Siganlling Port.rw Enumeration .1.3.6.1.4.1.2879.2.6.7.1.3.1.5 |
sonusSipSigPortModeMode of the SIP Signalling Port.rw SonusServiceState (SONUS-TC) .1.3.6.1.4.1.2879.2.6.7.1.3.1.6 |
sonusSipSigPortStateState of the SIP Signalling Port.rw SonusAdminState (SONUS-TC) .1.3.6.1.4.1.2879.2.6.7.1.3.1.7 |
sonusSipSigPortRowStatusThis is for SNMP use.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.2879.2.6.7.1.3.1.8 |
sonusSipSigPortAclStateACL checking state of the SIP Signalling portrw SonusAdminState (SONUS-TC) .1.3.6.1.4.1.2879.2.6.7.1.3.1.9 |
sonusSipSigPortStatusTableTable of SIP Signalling Port status. SEQUENCE OF SonusSipSigPortStatusEntry .1.3.6.1.4.1.2879.2.6.7.1.4 |
sonusSipSigPortStatusEntrySIP Signalling Port Status. SonusSipSigPortStatusEntry .1.3.6.1.4.1.2879.2.6.7.1.4.1 |
sonusSipSigPortStatusIndexIdentifies the Signal Listen Port entry.ro Integer32 .1.3.6.1.4.1.2879.2.6.7.1.4.1.1 |
sonusSipSigPortStatusIpAddressIP Address of the Sip Signalling Portro IpAddress .1.3.6.1.4.1.2879.2.6.7.1.4.1.2 |
sonusSipSigPortStatusNumUDP port number of SIP Signalling Port.ro Integer32 .1.3.6.1.4.1.2879.2.6.7.1.4.1.3 |
sonusSipSigPortStatusInterfaceThe interface type of SIP Call Signal Port. 'mgtnif' routes traffic over the gateway Managment ports. 'nif' routes traffic over one of the gateway PNS ports.ro Enumeration .1.3.6.1.4.1.2879.2.6.7.1.4.1.4 |
sonusSipSigPortStatusRoleRole of the Sip Call Siganlling Port.ro Enumeration .1.3.6.1.4.1.2879.2.6.7.1.4.1.5 |
sonusSipSigPortStatusNifThe network interface index of the port.ro Integer32 .1.3.6.1.4.1.2879.2.6.7.1.4.1.6 |
sonusSipSigPortStatusStateState of the SIP Signalling Port.ro SonusServiceState (SONUS-TC) .1.3.6.1.4.1.2879.2.6.7.1.4.1.7 |
sonusSipSigPortStatTableTable of SIP Signalling Port statistics data. SEQUENCE OF SonusSipSigPortStatEntry .1.3.6.1.4.1.2879.2.6.7.1.5 |
sonusSipSigPortStatEntrySIP Signalling Port Statistics. SonusSipSigPortStatEntry .1.3.6.1.4.1.2879.2.6.7.1.5.1 |
sonusSipSigPortStatIndexIdentifies the Signal Listen Port entry.ro Integer32 .1.3.6.1.4.1.2879.2.6.7.1.5.1.1 |
sonusSipSigPortStatIpAddressIP Address of the Sip Signalling Portro IpAddress .1.3.6.1.4.1.2879.2.6.7.1.5.1.2 |
sonusSipSigPortStatPortNumUDP port number of SIP Signalling Port.ro Integer32 .1.3.6.1.4.1.2879.2.6.7.1.5.1.3 |
sonusSipSigPortStatCountResetset opertion on this object resets all the statistics counts to zerorw Enumeration .1.3.6.1.4.1.2879.2.6.7.1.5.1.4 |
sonusSipSigPortStatCallRatenumber of SIP calls per second during the last minutero Integer32 .1.3.6.1.4.1.2879.2.6.7.1.5.1.5 |
sonusSipSigPortStatNumOrigCallsTotal number of outgoing calls sent out from this signaling portro Integer32 .1.3.6.1.4.1.2879.2.6.7.1.5.1.6 |
sonusSipSigPortStatNumTermCallsTotal number of incoming calls received on this signaling portro Integer32 .1.3.6.1.4.1.2879.2.6.7.1.5.1.7 |
sonusSipSigPortStatNumTxPdusThe total number of signalling PDUS sent out on this portro Counter64 .1.3.6.1.4.1.2879.2.6.7.1.5.1.8 |
sonusSipSigPortStatNumRxPdusThe total number of signalling PDUS received on this portro Counter64 .1.3.6.1.4.1.2879.2.6.7.1.5.1.9 |
sonusSipSigPortStatNumTxBytesThe total number of signalling BYTES sent out from this portro Counter64 .1.3.6.1.4.1.2879.2.6.7.1.5.1.10 |
sonusSipSigPortStatNumRxBytesThe total number of signalling BYTES received by this portro Counter64 .1.3.6.1.4.1.2879.2.6.7.1.5.1.11 |
sonusSipAcl OBJECT IDENTIFIER .1.3.6.1.4.1.2879.2.6.7.1.6 |
sonusSipAclNextIndexthe next valid index to use when creating a new sonusSipAclEntryro Integer32 .1.3.6.1.4.1.2879.2.6.7.1.6.1 |
sonusSipAclTableThis is the Application Server List SEQUENCE OF SonusSipAclEntry .1.3.6.1.4.1.2879.2.6.7.1.6.2 |
sonusSipAclEntryAn Application Server SonusSipAclEntry .1.3.6.1.4.1.2879.2.6.7.1.6.2.1 |
sonusSipRemoteAppSvrIndexIdentifies a remote application server entry.ro Integer32 .1.3.6.1.4.1.2879.2.6.7.1.6.2.1.1 |
sonusSipRemoteAppSvrNameName of the application server.rw SonusName (SONUS-TC) .1.3.6.1.4.1.2879.2.6.7.1.6.2.1.2 |
sonusSipRemoteAppSvrIpAddressIP Address of the application server.rw IpAddress .1.3.6.1.4.1.2879.2.6.7.1.6.2.1.3 |
sonusSipRemoteAppSvrRowStatusrow status of the application server.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.2879.2.6.7.1.6.2.1.4 |
sonusSipSignallingMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.2879.2.6.7.2 |
sonusSipSignallingMIBNotificationsPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.2879.2.6.7.2.0 |
sonusSipCallSigPortOpenNotificationThis trap indicates that a call signaling port is opened. NOTIFICATION-TYPE .1.3.6.1.4.1.2879.2.6.7.2.0.1 |
sonusSipCallSigPortCloseNotificationThis trap indicates that a call signaling port is closed. NOTIFICATION-TYPE .1.3.6.1.4.1.2879.2.6.7.2.0.2 |
sonusSipSignallingMIBNotificationsObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2879.2.6.7.2.1 |