Home/Catalog/SONUS-ALARM-CONTACT-MIB

SONUS-ALARM-CONTACT-MIB

AI MIB Summary

The SONUS-ALARM-CONTACT-MIB manages physical alarm contact interfaces on Sonus network equipment, monitoring the open/closed state of dry-contact sensors to trigger SNMP traps for hardware fault detection and environmental monitoring.

The MIB Module for Physical Alarm Contacts management.
Main OID:
sonusAlarmManagerMIB.1.3.6.1.4.1.2879.2.1.6
28
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

28 total
Object Name
sonusAlarmManagerMIBThe MIB Module for Physical Alarm Contacts management.
MODULE-IDENTITY
.1.3.6.1.4.1.2879.2.1.6
sonusAlarmManagerMIBObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2879.2.1.6.1
sonusAlarmOutAdmnTable
SEQUENCE OF SonusAlarmOutAdmnEntry
.1.3.6.1.4.1.2879.2.1.6.1.1
sonusAlarmOutAdmnEntry
SonusAlarmOutAdmnEntry
.1.3.6.1.4.1.2879.2.1.6.1.1.1
sonusAlarmOutAdmnShelfIndexIdentifies the target shelf within the node.ro
SonusShelfIndex (SONUS-TC)
.1.3.6.1.4.1.2879.2.1.6.1.1.1.1
sonusAlarmOutAdmnRelayIndexIdentifies the target outbound relay within the shelf.ro
Enumeration
.1.3.6.1.4.1.2879.2.1.6.1.1.1.2
sonusAlarmOutAdmnOperStateIf enabled, the relay will respond to system events by opening and closing. If disabled, then it will be left in the default state of 'Clear', where clear is relative to the 'sense' assigned to the relay. The default sense is Normal, which means a closed relay is considered in the alarm state.rw
SonusAdminState (SONUS-TC)
.1.3.6.1.4.1.2879.2.1.6.1.1.1.3
sonusAlarmOutAdmnValueDefault value for the relays, either ALARM or CLEAR. Alarm contact five can be manually reconfigured. Alarm Contacts 1 thru 4 have a fixed default state of CLEAR, and cannot be manually reconfiguredrw
Enumeration
.1.3.6.1.4.1.2879.2.1.6.1.1.1.4
sonusAlarmOutAdmnSenseSelect NORMAL if a CLOSED relay indicates an alarm condition. Select INVERTED if an OPEN relay indicates an alarm condition.rw
Enumeration
.1.3.6.1.4.1.2879.2.1.6.1.1.1.5
sonusAlarmOutAdmnStartDelayStart Delay will hold the outbound relays in reset for the time period(seconds) specified. This is intended to mitigate nuisance alarms when a shelf is first started.rw
Integer32
.1.3.6.1.4.1.2879.2.1.6.1.1.1.6
sonusAlarmOutAdmnCutoffCutoff will cause the outbound relay selected to be set to its alarm clear state, relative to the relay 'sense' setting. This allows the customer to disable an alarm after it has been set by some system event. Cutoff is a one shot event, which does not inhibit future additional alarms on that relay from occuring. Alarm Relays DO NOT automatically clear, and must be cleared manually with this feature.rw
Enumeration
.1.3.6.1.4.1.2879.2.1.6.1.1.1.7
sonusAlarmOutStatTableThis table describes the current status of the outbound alarm relays
SEQUENCE OF SonusAlarmOutStatEntry
.1.3.6.1.4.1.2879.2.1.6.1.2
sonusAlarmOutStatEntry
SonusAlarmOutStatEntry
.1.3.6.1.4.1.2879.2.1.6.1.2.1
sonusAlarmOutStatShelfIndexro
SonusShelfIndex (SONUS-TC)
.1.3.6.1.4.1.2879.2.1.6.1.2.1.1
sonusAlarmOutStatRelayIndexro
Enumeration
.1.3.6.1.4.1.2879.2.1.6.1.2.1.2
sonusAlarmOutStatStatusIndicates the operational status of the alarm relay contacts.ro
Enumeration
.1.3.6.1.4.1.2879.2.1.6.1.2.1.3
sonusAlarmOutStatStartDelayTRUE if the alarm contact is in Start Delay, FALSE otherwise. Start Delay is a programmable time period that when the Shelf boots, alarm events will NOT trigger the corresponding alarm contact. It is intended to mitigate nuisance alarms when a shelf is first started.ro
SonusBoolean (SONUS-TC)
.1.3.6.1.4.1.2879.2.1.6.1.2.1.4
sonusAlarmInStatTableThis table describes the current status of the inbound alarm ports
SEQUENCE OF SonusAlarmInStatEntry
.1.3.6.1.4.1.2879.2.1.6.1.3
sonusAlarmInStatEntry
SonusAlarmInStatEntry
.1.3.6.1.4.1.2879.2.1.6.1.3.1
sonusAlarmInStatShelfIndexro
SonusShelfIndex (SONUS-TC)
.1.3.6.1.4.1.2879.2.1.6.1.3.1.1
sonusAlarmInStatPortro
Integer32
.1.3.6.1.4.1.2879.2.1.6.1.3.1.2
sonusAlarmInStatStatusIndicates the operational status of the inbound alarm contacts.ro
Enumeration
.1.3.6.1.4.1.2879.2.1.6.1.3.1.3
sonusAlarmManagerMIBNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.2879.2.1.6.2
sonusAlarmManagerMIBNotificationsPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.2879.2.1.6.2.0
sonusAlarmManagerInboundNotificationThis trap indicates that a change of state has occured on the inbound alarm port
NOTIFICATION-TYPE
.1.3.6.1.4.1.2879.2.1.6.2.0.1
sonusAlarmManagerMIBNotificationsObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2879.2.1.6.2.1
sonusAlarmPortIndexAlarm IN port which has changed state.ro
Integer32
.1.3.6.1.4.1.2879.2.1.6.2.1.1
sonusAlarmPortStateThe current state of the inbound alarm port.ro
Enumeration
.1.3.6.1.4.1.2879.2.1.6.2.1.2
SONUS-ALARM-CONTACT-MIB - SNMP MIB Reference | MIBs Explorer