Home/Catalog/SIEMENS-HP4KHIM-MIB

SIEMENS-HP4KHIM-MIB

Detailed view of the defined objects, syntax rules, and hierarchical paths.

433
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

433 total
Object Name
siemens
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329
iandcAdmin
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2
hp4khim
MODULE-IDENTITY
.1.3.6.1.4.1.4329.2.51
himWelcomePage
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.1
himWelPgTable
SEQUENCE OF HimWelPgEntry
.1.3.6.1.4.1.4329.2.51.1.1
himWelPgEntry
HimWelPgEntry
.1.3.6.1.4.1.4329.2.51.1.1.1
himWelPgPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.1.1.1.1
himWelPgSysNoThis field contains the system number (max. 17 characters).ro
HimSwitchNumber
.1.3.6.1.4.1.4329.2.51.1.1.1.2
himHP4KVersionThis field contains the Hicom/HiPath version number of the system (max. 4 characters).ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.1.1.1.3
himSystemReleaseThis field contains the system release number of the system (max. 2 characters).ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.1.1.1.4
himRevisionLevelThis field contains the revision number of the system software (max. 2 characters).ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.1.1.1.5
himHWArchitectureThis field contains the information on hardware architecture in the format [hw-architecture][system-variant][hw-design] [hw-architecture] Abbreviation describing hardware architecture. F.i '4300', '350E', etc. [system-variant] H40: SYSTEM VARIANT 40 H80: SYSTEM VARIANT 80 H600: SYSTEM VARIANT 600 [hw-design] ECX: HARDWARE DESIGN EXTENDED COMPACT EXTENDED ECDSC: HARDWARE DESIGN EXTENDED COMPACT DSC CXE: HARDWARE DESIGN EXTENDED COMPACT CXEro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.1.1.1.6
himHWArchitectureTypeThis field contains abbreviation describing hardware architecture type (max. 3 characters).ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.1.1.1.7
himOperationModeThis field contains the operating mode of the system. Possible Values: SIMPLEX: OPERATING MODE SIMPLEX DUPLEX: OPERATING MODE DUPLEX REDUNDANCYro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.1.1.1.8
himSWUProc1These fields contains the name of the SWU processor board (max. 8 characters). SWU = Switching Unit Possible values: - CC-A - CC-Bro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.1.1.1.9
himSWUMemory1These fields contain the size of the SWU memory for each processor card. SWU = Switching Unitro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.1.1.1.10
himSWUProc2These fields contains the name of the SWU processor board (max. 8 characters). SWU = Switching Unit Possible values: - CC-A - CC-Bro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.1.1.1.11
himSWUMemory2These fields contain the size of the SWU memory for each processor card. SWU = Switching Unitro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.1.1.1.12
himSwitchData
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.2
himTechInfoTable
SEQUENCE OF HimTechInfoEntry
.1.3.6.1.4.1.4329.2.51.2.1
himTechInfoEntry
HimTechInfoEntry
.1.3.6.1.4.1.4329.2.51.2.1.1
himTechInfoPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.2.1.1.1
himTechInfoInfoNoThis field contains the number of the subsystem. This number can be assigned as required when configuring the subsystem.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.2.1.1.2
himTechInfoDateThis field contains the date on which the subsystem was configured.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.2.1.1.3
himTechInfoTechnicalDataThis field contains the technical data of the subsystem.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.2.1.1.4
himTechInfoNumberThis field contains the number of each subsystem configured.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.2.1.1.5
himTechInfoExtraTextThis field contains additional text.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.2.1.1.6
himNotepadDataTableThis node contains the system data entered in a notepad. The table for notepad entries holds a maximum of 30 data records.
SEQUENCE OF HimNotepadDataEntry
.1.3.6.1.4.1.4329.2.51.2.2
himNotepadDataEntry
HimNotepadDataEntry
.1.3.6.1.4.1.4329.2.51.2.2.1
himNotepadDataPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.2.2.1.1
himNotepadDataInfoNoThis field contains the number of the subsystem. This number is assigned permanently when configuring the subsystem.ro
Unsigned32
.1.3.6.1.4.1.4329.2.51.2.2.1.2
himNotepadDataDateThis field contains the date on which the subsystem was configured.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.2.2.1.3
himNotepadDataTextThis field contains the technical data of the subsystem.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.2.2.1.4
himProjPlanInfoTableThis screen makes it possible to generate a file with project planning data.
SEQUENCE OF HimProjPlanInfoEntry
.1.3.6.1.4.1.4329.2.51.2.3
himProjPlanInfoEntry
HimProjPlanInfoEntry
.1.3.6.1.4.1.4329.2.51.2.3.1
himProjPlanPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.2.3.1.1
himProjPlanInfoFileThis field contains the name of the project planning file.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.2.3.1.2
himProjPlanInfoCreationDateThis field contains the date on which the project planning file was generated.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.2.3.1.3
himProjPlanInfoCreationTimeThis field contains the time at which the project planning file was generated.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.2.3.1.4
himSpecSwitchData
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.3
himSpecShelfDataTableAll subscriber and trunk-related lines are grouped within LTU (Line/Trunk Unit) frames. Each frame has several slots for modules. The frame is connected to the system via the LTUC control board. This table contains the frame configuration.
SEQUENCE OF HimSpecShelfDataEntry
.1.3.6.1.4.1.4329.2.51.3.1
himSpecShelfDataEntry
HimSpecShelfDataEntry
.1.3.6.1.4.1.4329.2.51.3.1.1
himSpecShelfDataPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.3.1.1.1
himSpecShelfDataAddressThis field contains the address of the shelf in format LTG.LTU. LTG:Line/Trunk Group LTU: Line/Trunk Unitro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.3.1.1.2
himSpecShelfDataFrameTypeThis field contains the part number of the frame.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.3.1.1.3
himSpecShelfDataLTUThis field contains type of LTU (Line/Trunk Unit) frame. Possible values for LTU frame type: - PREATL - frametype for Preatlantic Hicom Types - CC40F - basisframe for 40CMX - CC80W - basisframe for 80CMX - CC80F - basisframe for 80CMX/DSC and CXE - L80XF - for 80CMX/DSC, CXE, 600ECS and AP shelves - L80XW - extension frame for 80CMX/DSC - LTUW - frame for 600ECX and AP shelves Possible values for AP shelf type: - L80XF - for 80CMX/DSC, CXE, 600ECS and AP shelves - LTUW - frame for 600ECX and AP shelves - INCH19 - 19 inch frame for AP shelvesro
Enumeration
.1.3.6.1.4.1.4329.2.51.3.1.1.4
himSpecShelfDataNetworkTypeThis field contains connection type of LTU frame / AP shelf.ro
HimShelfNWType
.1.3.6.1.4.1.4329.2.51.3.1.1.5
himSpecShelfDataNetworkAddressThis field contains network IP address.ro
IpAddress
.1.3.6.1.4.1.4329.2.51.3.1.1.6
himSpecShelfDataRemoteThis field shows if frame is remote. Possible values: - yes - frame is remote - no - frame is not remotero
OCTET STRING
.1.3.6.1.4.1.4329.2.51.3.1.1.7
himSpecShelfDataLocationThis field contains postal address (city, street, building, ..) , where a FLEX LTU or an AP shelf is located.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.3.1.1.8
himSpecShelfDataLTUCThis field contains part number adding LTUC module. LTUC: Line/Trunk Unit Control.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.3.1.1.9
himSWUBoardTableThis table contains the configuration of the peripheral boards. Periphery Assemblies Peripheral and ring generator assemblies as well as SIU are configured in the LTU. The board is entered in the SWU database. LTU = Line/Trunk Unit SIU = Signaling Interface Unit SWU = Switching Unit
SEQUENCE OF HimSWUBoardEntry
.1.3.6.1.4.1.4329.2.51.3.2
himSWUBoardEntry
HimSWUBoardEntry
.1.3.6.1.4.1.4329.2.51.3.2.1
himSWUBoardPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.3.2.1.1
himSWUBoardPENThis field contains the name of the board PEN. PEN: Port Equipment Number The PEN is displayed in the following format: [LTG]-[LTU]-[EBT]. LTG: Line/Trunk Group LTU: Line/Trunk Unit EBT: Slotro
HimPEN
.1.3.6.1.4.1.4329.2.51.3.2.1.2
himSWUBoardOverlayLTUThis field contains the name of the overlay LTU (Line/Trunk Unit).ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.3.2.1.3
himSWUBoardTypeThis field contains the name of the configured board.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.3.2.1.4
himSWUBoardNominalThis field contains the name of the nominal board.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.3.2.1.5
himSWUBoardActualThis field contains part number of the board that is plugged in.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.3.2.1.6
hhimSWUBoardFirmwareThis field contains the name of the firmware.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.3.2.1.7
himSWUBoardRevThis field contains the revision of the board.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.3.2.1.8
himSWUBoardFunctIdFunction identification number for boards with more than one functions (e.g. SIUX, STMA, SLMO24).ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.3.2.1.9
himSWUBoardModeThis field contains the mode of the board. The mode is only displayed for the RG/ACGEN board.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.3.2.1.10
himSWUBoardLWNoThis field contains the number of the loadware.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.3.2.1.11
himSWUBoardLWInterVerThis field contains the interface version of the board.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.3.2.1.12
himSWUBoardLWNameThis field contains the file name of the loadware file or of the initialization file.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.3.2.1.13
himSWUBoardLWDateThis field contains the date on which the loadware or the initialization file was generated.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.3.2.1.14
himSWUPeriphery
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.4
himPSIOAssTableThis table contains the PSIO assemblies data.
SEQUENCE OF HimPSIOAssEntry
.1.3.6.1.4.1.4329.2.51.4.1
himPSIOAssEntry
HimPSIOAssEntry
.1.3.6.1.4.1.4329.2.51.4.1.1
himPSIOAssPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.4.1.1.1
himPSIOAssPENThis field contains the name of the board PEN. PEN: Port Equipment Number The PEN is displayed in the following format: [LTG]-[LTU]-[EBT]. LTG: Line/Trunk Group LTU: Line/Trunk Unit EBT: Slotro
HimPEN
.1.3.6.1.4.1.4329.2.51.4.1.1.2
himPSIOAssAssemblyThis field contains the name of the PSIO board. PSIO: Peripheral Serial Input Outputro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.4.1.1.3
himPSIOAssActualThis field contains the part number of the PSIO board.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.4.1.1.4
himPSIOAssFirmwareThis field contains the firmware name of the PSIO board.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.4.1.1.5
himSerialLineTableThis table contains the serial interfaces data.
SEQUENCE OF HimSerialLineEntry
.1.3.6.1.4.1.4329.2.51.4.2
himSerialLineEntry
HimSerialLineEntry
.1.3.6.1.4.1.4329.2.51.4.2.1
himSerialLinePabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.4.2.1.1
himSerialLineNumberThis field contains the physical line number of the interface. Possible Values: numeric, 8-63ro
Unsigned32
.1.3.6.1.4.1.4329.2.51.4.2.1.2
himSerialLineBoardTypeThis field contains abbreviation name of the board type.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.4.2.1.3
himSerialLineSpeedThis field contains standardized transmission speed (baud rate). Possible Values: 50, 100, 200, 300, 600, 1200, 2400, 4800, 9600, 19200.ro
Unsigned32
.1.3.6.1.4.1.4329.2.51.4.2.1.4
himSerialLineLogDevNameThis field contains the logical device name of the line. Possible Values: Value - Description CON1 - LOGICAL DEVICE CONNECTION,TERMINAL 1 CON2 - LOGICAL DEVICE CONNECTION,TERMINAL 2 CON3 - LOGICAL DEVICE CONNECTION,TERMINAL 3 CON4 - LOGICAL DEVICE CONNECTION,TERMINAL 4 CON5 - LOGICAL DEVICE CONNECTION 5 CON6 - LOGICAL DEVICE CONNECTION 6 PR1 - LOGICAL DEVICE:LINE PRINTER 1 PR2 - LOGICAL DEVICE:LINE PRINTER 2 PR3 - LOGICAL DEVICE:LINE PRINTER 3 PR4 - LOGICAL DEVICE:LINE PRINTER 4ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.4.2.1.5
himSerialLineDevTypeThis field contains the device type of the line. Possible Values: Value - Description PT88 - DEVICE TYPE QUOSC - QUME-ONLY-SCREEN QUOPT - QUME-ONLY-PT88 QUSCAPT - QUME-SCREEN-AND-PT88 PCOSC - PC-D-ONLY-SCREEN PCOPT - PC-D-ONLY-PT88 PCSCAPT - PC-D-SCREEN-AND-PT88 ASC - ASCII-CODE EBC - EBCDIC CODE RSV1 - RESERVED DEVICE TYPE 1 RSV2 - RESERVED DEVICE TYPE 2 RSV3 - RESERVED DEVICE TYPE 3ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.4.2.1.6
himSerialLineTypeThis field contains the line type (operation of synchronous lines (terminals) connected via V24 modems). Possible values: - ASY: asynchronous line type - V24: ccitt rec v24ro
Enumeration
.1.3.6.1.4.1.4329.2.51.4.2.1.7
himSCSIDevTableThis table contains the data for the SCSI devices connected.
SEQUENCE OF HimSCSIDevEntry
.1.3.6.1.4.1.4329.2.51.4.3
himSCSIDevEntry
HimSCSIDevEntry
.1.3.6.1.4.1.4329.2.51.4.3.1
himSCSIDevPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.4.3.1.1
himSCSIDevIdThis field contains the type of SCSI device.ro
Unsigned32
.1.3.6.1.4.1.4329.2.51.4.3.1.2
himSCSIDevTypeThis field contains the SCSI ID of the device.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.4.3.1.3
himSCSIDevNameThis field contains the name of the SCSI device in format: [vendor] [product number].ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.4.3.1.4
himSCSIDevFirmwareThis field contains the firmware name of the SCSI device.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.4.3.1.5
himSCSIDevLoadDriveThis field displays (if activity is in progress) the device from which the operating system and the database are started.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.4.3.1.6
himCentralSwitchData
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.5
himCabinetTableThis table contains the data for configuring the cabinets and frames in a system. They reflect the physical structure of the system.
SEQUENCE OF HimCabinetEntry
.1.3.6.1.4.1.4329.2.51.5.1
himCabinetEntry
HimCabinetEntry
.1.3.6.1.4.1.4329.2.51.5.1.1
himCabPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.5.1.1.1
himCabAddrThis field contains the cabinet address. Structure of cabinet address: P 1 01 | | |__Number of cabinet in cabinet row | |_____Units, position of cabinet row |_______Tens (P=0, Q=1), position of the cabinetro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.5.1.1.2
himCabPhysAddrro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.5.1.1.3
himCabCabinetThis field contains the name of the cabinet.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.5.1.1.4
himCabPartNoThis field contains the part number of the cabinet.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.5.1.1.5
himCabShelfNoThis field contains the number of the shelf.ro
Unsigned32
.1.3.6.1.4.1.4329.2.51.5.1.1.6
himCabFrameThis field contains the name of the frame.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.5.1.1.7
himCabPid1This field contains the processor ID 1.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.5.1.1.8
himCabPid2This field contains the processor ID 2.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.5.1.1.9
himCabPid3This field contains the processor ID 2.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.5.1.1.10
himCabLTUNoThis field contains the number of the LTU (Line/Trunk Unit). The LTU range is divided in two parts: HHS (HICOM Host System) and AP (Access Point). The available values of the ranges are: HHS 1-15 and AP 17-99. The LTU 16 is forbidden. There are existing shelfes which are allowed only in HHS and others which are allowed only in the AP range.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.5.1.1.11
himMemScalingTableThis screen contains the memory parameters for each of the devices or features specified. The values are only displayed in Configuration Management. See also DIMSU parameter list.
SEQUENCE OF HimMemScalingEntry
.1.3.6.1.4.1.4329.2.51.5.2
himMemScalingEntry
HimMemScalingEntry
.1.3.6.1.4.1.4329.2.51.5.2.1
himMemScalingPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.5.2.1.1
himMemScalingUnitThis field contains the parameter name (AMO DIMSU).ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.5.2.1.2
himMemScalingUsedThis value specifies the number of memory elements already used up. The comparison with the value in the Maximum field indicates how much of the allocated memory is still available for configuring devices or features.ro
Integer32
.1.3.6.1.4.1.4329.2.51.5.2.1.3
himMemScalingMaxUsedThis field contains the number of memory elements allocated.ro
Integer32
.1.3.6.1.4.1.4329.2.51.5.2.1.4
himMemScalingAllocatedThis field displays the maximum number of memory elements that once have been used up during the lifetime of the switch ('high water mark'). It gives an indication how much memory was necessary at one time, so it is advised to not reduce the Maximum value below this value.ro
Integer32
.1.3.6.1.4.1.4329.2.51.5.2.1.5
himMemScalingStandardStandard is the advised value to be set in the Maximum field, if you don't have special needs to set it to a specific value. If you set all devices and features to the standard values it is guaranteed that you don't run out of DIMSU memory.ro
Integer32
.1.3.6.1.4.1.4329.2.51.5.2.1.6
himMemScalingSysMaxThis field contains the maximum number of possible memory elements.ro
Integer32
.1.3.6.1.4.1.4329.2.51.5.2.1.7
himGeneralSwitchData
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.6
himDBConfSys
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.6.1
himDBConfSysTable
SEQUENCE OF HimDBConfSysEntry
.1.3.6.1.4.1.4329.2.51.6.1.1
himDBConfSysEntry
HimDBConfSysEntry
.1.3.6.1.4.1.4329.2.51.6.1.1.1
himDBConfSysPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.6.1.1.1.1
himDBConfSysClass1This field contains the name of the system.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.1.1.1.2
himDBConfSysClass2This field contains the coded name of the system.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.1.1.1.3
himDBConfSysHWAss1This field contains the hardware ID of the system.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.1.1.1.4
himDBConfSysHWAss2This field contains the shortened hardware ID of the system.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.1.1.1.5
himDBConfSysDevLine1This field contains the name of the product line.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.1.1.1.6
himDBConfSysDevLine2This field contains the shortened name of the product line. Possible values: - H300: EUROPE DEVELOPMENT - HUSA: US DEVELOPMENTro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.1.1.1.7
himDBConfSysOpModeThis field contains the operating mode of the system. Possible Values: - SIMPLEX: OPERATING MODE SIMPLEX - DUPLEX: OPERATING MODE DUPLEX REDUNDANCYro
Enumeration
.1.3.6.1.4.1.4329.2.51.6.1.1.1.8
himDBConfSysResTypeThis field contains the restart identifier.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.1.1.1.9
himDBConfSysHWArchThis field contains the name of the hardware architecture.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.1.1.1.10
himDBConfSysHWArchTypeThis field contains the name of the hardware architecture type.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.1.1.1.11
himDBConfSysNoThis field contains the number of the system.ro
HimSwitchNumber
.1.3.6.1.4.1.4329.2.51.6.1.1.1.12
himDBConfSysLocThis field contains the name of the location in which the system is installed. Possible Values: - CUSTOMER (customer) - SUPPORT (support) - TESTLAB (testlab)ro
Enumeration
.1.3.6.1.4.1.4329.2.51.6.1.1.1.13
himDBConfSysBaseAppThis field contains the name of the base application.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.1.1.1.14
himDBConfSysDBAppThis field contains the name of the database application.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.1.1.1.15
himDBConfSysIDThis field contains the system identification.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.1.1.1.16
himDBConfHW
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.6.2
himDBConfHWTable
SEQUENCE OF HimDBConfHWEntry
.1.3.6.1.4.1.4329.2.51.6.2.1
himDBConfHWEntry
HimDBConfHWEntry
.1.3.6.1.4.1.4329.2.51.6.2.1.1
himDBConfHWPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.6.2.1.1.1
himDBConfHWLTGThis field contains the number of LTGs in the system. LTG: Line/Trunk Groupro
Integer32 (1)
.1.3.6.1.4.1.4329.2.51.6.2.1.1.2
himDBConfHWLTUThis field contains the number of LTUs in the system. LTU: Line/Trunk Unitro
Integer32 (1..15 | 17..99)
.1.3.6.1.4.1.4329.2.51.6.2.1.1.3
himDBConfHWLinesThis field contains the number of lines in the system.ro
Integer32
.1.3.6.1.4.1.4329.2.51.6.2.1.1.4
himDBConfHWPortsThis field contains the number of ports in the system.ro
Integer32
.1.3.6.1.4.1.4329.2.51.6.2.1.1.5
himDBConfHWPBCThis field contains the number of peripheral board controllers (PBC) in the system.ro
Integer32
.1.3.6.1.4.1.4329.2.51.6.2.1.1.6
himDBConfHWMTSBdPerGSNThis field contains the number of memory time switches (MTS) per group switching network (GSN).ro
Integer32
.1.3.6.1.4.1.4329.2.51.6.2.1.1.7
himDBConfHWSIUPPerLTUThis field contains the number of SIUP boards per LTU (Line/Trunk Unit).ro
Integer32
.1.3.6.1.4.1.4329.2.51.6.2.1.1.8
himDBConfHWDIUCPerLTUThis field contains the number of DIUC boards per LTU (Line/Trunk Unit).ro
Integer32
.1.3.6.1.4.1.4329.2.51.6.2.1.1.9
himDBConfHWHwyPerMTSBdThis field contains the number highways (HYW) per MTS board.ro
Integer32
.1.3.6.1.4.1.4329.2.51.6.2.1.1.10
himDBConfHWHDLCPerDCLThis field contains the number of high level data link control (HDLC) channels per data communication link (DCL).ro
Integer32
.1.3.6.1.4.1.4329.2.51.6.2.1.1.11
himDBConfHWPBCPerDCLThis field contains the number of peripheral board controllers (PBC) per data communication link (DCL).ro
Integer32
.1.3.6.1.4.1.4329.2.51.6.2.1.1.12
himDBConfHWStdSIULineThis field contains the number of signaling unit lines. SIU: Signaling-Unitro
Integer32
.1.3.6.1.4.1.4329.2.51.6.2.1.1.13
himDBConfHWConfLineThis field contains the number of lines in the CONFERENCE board.ro
Integer32
.1.3.6.1.4.1.4329.2.51.6.2.1.1.14
himDBConfHWDBDimThis field contains the name of the database dimensioning.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.2.1.1.15
himDBConfHWTableVerThis field contains the version of the Conf table.ro
Integer32
.1.3.6.1.4.1.4329.2.51.6.2.1.1.16
himHWData
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.6.3
himHWDataTable
SEQUENCE OF HimHWDataEntry
.1.3.6.1.4.1.4329.2.51.6.3.1
himHWDataEntry
HimHWDataEntry
.1.3.6.1.4.1.4329.2.51.6.3.1.1
himHWDataPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.6.3.1.1.1
himHWArchThis field contains the name of the hardware architecture.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.3.1.1.2
himHWArchTypeThis field contains the name of the hardware architecture type.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.3.1.1.3
himHWOpModeThis field contains the name of the operating mode.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.3.1.1.4
himHWSWUProc1These fields contain the name of the SWU processor board (max. 8 characters). SWU = Switching Unit Possible values: - CC-A - CC-Bro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.3.1.1.5
himHWSWUMem1These fields contain the size of the SWU memory for each processor board. SWU = Switching Unitro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.3.1.1.6
himHWSWUProc2These fields contain the name of the SWU processor board (max. 8 characters). SWU = Switching Unit Possible values: - CC-A - CC-Bro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.3.1.1.7
himHWSWUMem2These fields contain the size of the SWU memory for each processor board. SWU = Switching Unitro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.3.1.1.8
himHWADPProcThis field contains the name of the ADP processor.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.3.1.1.9
himHWADPMemThis field contains the size of memory used by the ADP.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.3.1.1.10
himLWDataOnCB
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.6.4
himLWDataOnCBTable
SEQUENCE OF HimLWDataOnCBEntry
.1.3.6.1.4.1.4329.2.51.6.4.1
himLWDataOnCBEntry
HimLWDataOnCBEntry
.1.3.6.1.4.1.4329.2.51.6.4.1.1
himLWDataOnCBPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.6.4.1.1.1
himLWOnCBAssThis field contains the hardware ID of the board. Note: Certain types of processor boards (e. g. DPC5) are using only firmware. Therefore, no loadware data is displayed and this field remains empty.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.4.1.1.2
himLWOnCBPBCAddrThis field contains the peripheral board controller (PBC) address of the module. Note: Certain types of processor boards (e. g. DPC5) are using only firmware. Therefore, no loadware data is displayed and this field remains empty.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.4.1.1.3
himLWOnCBFileNameThis field contains the filename of the loadware file. Note: Certain types of processor boards (e. g. DPC5) are using only firmware. Therefore, no loadware data is displayed and this field remains empty.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.4.1.1.4
himLWOnCBProdTimeThis field contains the production date of the loadware. Note:Certain types of processor boards (e. g. DPC5) are using only firmware. Therefore, no loadware data is displayed and this field remains empty.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.4.1.1.5
himLWDataOnProc
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.6.5
himLWOnProcTable
SEQUENCE OF HimLWOnProcEntry
.1.3.6.1.4.1.4329.2.51.6.5.1
himLWOnProcEntry
HimLWOnProcEntry
.1.3.6.1.4.1.4329.2.51.6.5.1.1
himLWOnProcPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.6.5.1.1.1
himLWOnProcAssThis field contains the name of the directory where the file with information on Loadware resides, e. g. CCA, CCB or ADP (max. 3 characters).ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.5.1.1.2
himLWOnProcInfoTypeThis field contains the boot type. It represents the file name also.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.5.1.1.3
himLWOnProcLWIdThis field contains the name of the loadware.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.5.1.1.4
himLWOnProcLWIdCMPThis field contains the name of the loadware ID for the CMP. This field contains the '-' character if it is not relevant to this board.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.5.1.1.5
himLWOnProcLWIdLPThis field contains the name of the loadware ID for the LP. This field contains the '-' character if it is not relevant to this board.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.5.1.1.6
himLWDataOnCSIU
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.6.6
himLWOnCSIUTableThis table contains the loadware data on the central SIU (Signaling Interface Unit).
SEQUENCE OF HimLWOnCSIUEntry
.1.3.6.1.4.1.4329.2.51.6.6.1
himLWOnCSIUEntry
HimLWOnCSIUEntry
.1.3.6.1.4.1.4329.2.51.6.6.1.1
himLWOnCSIUPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.6.6.1.1.1
himLWOnCSIUNominalThis field contains the name of the nominal SIU (Signaling Interface Unit).ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.6.1.1.2
himLWOnCSIULWNoThis field contains the name of the SIU (Signaling Interface Unit) loadware.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.6.1.1.3
himLWOnCSIUProcThis field contains the name of the processor in the SIU (Signaling Interface Unit).ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.6.1.1.4
himLWOnCSIUSlotThis field contains the name of the SIU (Signaling Interface Unit) slot.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.6.1.1.5
himLWOnCSIUActualThis field contains the name of the current SIU (Signaling Interface Unit).ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.6.1.1.6
himLWOnCSIUFileNameThis field contains the file name of the loadware file or of the initialization file.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.6.1.1.7
himLWOnCSIUFileProdThis field contains the date on which the loadware or the initialization file was generated.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.6.1.1.8
himMacAddress
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.6.7
himMacAddrTableThis table contains the C-LAN and IPDA MAC addresses which are read during the boot process.
SEQUENCE OF HimMacAddrEntry
.1.3.6.1.4.1.4329.2.51.6.7.1
himMacAddrEntry
HimMacAddrEntry
.1.3.6.1.4.1.4329.2.51.6.7.1.1
himMacAddrPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.6.7.1.1.1
himMacAddrProcThis field contains the name of the processor (CCA, CCB or ADP - max 3 characters). It is also the name of the Unix directory where the file with information on MAC address resides.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.7.1.1.2
himMacAddrInfoTypeThis field contains the condition on which the mac addresses are available.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.6.7.1.1.3
himMacAddrCLanThis field contains the MAC address for UW7 part. The format is following: 'xx xx xx xx xx xx'.ro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.4329.2.51.6.7.1.1.4
himMacAddrIPDAThis field contains the MAC address for RMX part. The format is following: 'xx xx xx xx xx xx'.ro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.4329.2.51.6.7.1.1.5
himFeatures
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.7
himMarketingFeatures
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.7.1
himMarkFeatTable
SEQUENCE OF HimMarkFeatEntry
.1.3.6.1.4.1.4329.2.51.7.1.1
himMarkFeatEntry
HimMarkFeatEntry
.1.3.6.1.4.1.4329.2.51.7.1.1.1
himMarkFeatPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.7.1.1.1.1
himMarkFeatVerThis field contains the version of the software package. Format explanation: H 2 04 | |__SW version (01=EV1.0; 02=EV2.0; 03=EV3.0; 04=HiPath 4000 V1.0; 05=HiPath 4000 V2.0; 06=HiPath 4000 V3.0) | |_____Marketing concept (1=Old, 2=New)ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.7.1.1.1.2
himMarkFeatSerNoThis field contains the serial number of the software package.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.7.1.1.1.3
himMarkFeatHWIdThis field contains the dongle ID of the hardware dongle connected.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.7.1.1.1.4
himMarkFeatInstallDateThis field contains the date on which the code word was entered.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.7.1.1.1.5
himMarkFeatExpiryDateThis field contains the date on which the code word will expire.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.7.1.1.1.6
himMarkFeatConfCodeThis field contains codeword entry confirmation code.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.7.1.1.1.7
himMarkFeatTrialModeActThis field shows whether trial mode is active. Possible values: - yes - trial mode is activated - no - trial mode is not activatedro
HimYesNo
.1.3.6.1.4.1.4329.2.51.7.1.1.1.8
himMarkFeatTrialRemDaysThis field contains number of remaining days of an active trial mode.ro
Integer32
.1.3.6.1.4.1.4329.2.51.7.1.1.1.9
himSalesFeatTable
SEQUENCE OF HimSalesFeatEntry
.1.3.6.1.4.1.4329.2.51.7.1.2
himSalesFeatEntry
HimSalesFeatEntry
.1.3.6.1.4.1.4329.2.51.7.1.2.1
himSalesFeatPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.7.1.2.1.1
himSalesFeatMarketPackIdThis column contains the CM ids of the marketing packages.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.7.1.2.1.2
himSalesFeatMarketPackThis column contains the names of the marketing packages.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.7.1.2.1.3
himSalesFeatContractThis column indicates whether the marketing packages have been purchased.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.7.1.2.1.4
himSalesFeatUsedThis column indicates whether the marketing packages have been used.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.7.1.2.1.5
himSalesFeatFreeThis field contains the number of free packages.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.7.1.2.1.6
himSalesFeatMarkForTrialThis field contains the number of packages (entites) marked for trial or blocked (if the trial mode is not active).ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.7.1.2.1.7
himTechFeatures
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.7.2
himTechFeatTable
SEQUENCE OF HimTechFeatEntry
.1.3.6.1.4.1.4329.2.51.7.2.1
himTechFeatEntryThis table contains all enabled and disabled customer-specific features. Use the Object List view to display a list of all features availavle.
HimTechFeatEntry
.1.3.6.1.4.1.4329.2.51.7.2.1.1
himTechFeatPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.7.2.1.1.1
himTechFeatIdThis field contains the CM id of the customer-specific feature.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.7.2.1.1.2
himTechFeatNameThis field contains the name of the customer-specific feature.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.7.2.1.1.3
himTechFeatStateThis field contains the status of the customer-specific feature.ro
HimYesNo
.1.3.6.1.4.1.4329.2.51.7.2.1.1.4
himAPSPatches
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.8
himSwitchAPS
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.8.1
himSwitchAPSTable
SEQUENCE OF HimSwitchAPSEntry
.1.3.6.1.4.1.4329.2.51.8.1.1
himSwitchAPSEntry
HimSwitchAPSEntry
.1.3.6.1.4.1.4329.2.51.8.1.1.1
himSwitchAPSPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.8.1.1.1.1
himSwitchAPSNamero
OCTET STRING
.1.3.6.1.4.1.4329.2.51.8.1.1.1.2
himSwitchAPSCorrVerro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.8.1.1.1.3
himSwitchAPSPartNoro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.8.1.1.1.4
himReplacedAMOs
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.8.2
himReplAMOTableThis table displays those AMOs that have been changed since the last system correction version.
SEQUENCE OF HimReplAMOEntry
.1.3.6.1.4.1.4329.2.51.8.2.1
himReplAMOEntry
HimReplAMOEntry
.1.3.6.1.4.1.4329.2.51.8.2.1.1
himReplAMOPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.8.2.1.1.1
himReplAMOAPSThe APS in which the change has been made.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.8.2.1.1.2
himReplAMONameThis field contains the name of the AMO command.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.8.2.1.1.3
himReplAMOInAPSDirThis field contains the name of the subsystem in the DIR file.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.8.2.1.1.4
himReplAMOSubsystemThis field contains the name of the current subsystem.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.8.2.1.1.5
himPatchInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.8.3
himPatchInfoTableThis table contains information on the software patches that have been implemented.
SEQUENCE OF HimPatchInfoEntry
.1.3.6.1.4.1.4329.2.51.8.3.1
himPatchInfoEntry
HimPatchInfoEntry
.1.3.6.1.4.1.4329.2.51.8.3.1.1
himPatchInfoPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.8.3.1.1.1
himPatchInfoPatchNoThis field contains the number of the patch.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.8.3.1.1.2
himPatchInfoPatchGroupThis field contains the name of the patch group.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.8.3.1.1.3
himPatchInfoOptThis field represents an indicator that the patch is: - optional: not part of patch packet, - not optional: a part of patch packet (represents the whole list of internal activated/deactivated patches). The purpose of this field is to give user an option to display all patches as well as only optional ones.ro
HimYesNo
.1.3.6.1.4.1.4329.2.51.8.3.1.1.4
himPatchInfoActHDThis field indicates whether the patch is enabled on the hard disk.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.8.3.1.1.5
himPatchInfoActADPThis field indicates whether the patch is enabled on the ADP.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.8.3.1.1.6
himPatchInfoActBPThis field indicates whether the patch is enabled on the A/B processor.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.8.3.1.1.7
himSWVersion
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.9
himSWVerOnProcTableThis table contains data on the software versions loaded on the processor boards.
SEQUENCE OF HimSWVerOnProcEntry
.1.3.6.1.4.1.4329.2.51.9.1
himSWVerOnProcEntry
HimSWVerOnProcEntry
.1.3.6.1.4.1.4329.2.51.9.1.1
himSWVerOnProcPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.9.1.1.1
himSWVerOnProcSrcThis field contains the name of the software source.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.9.1.1.2
himSWVerOnProcSWVerThis field contains the name of the software version of the ADP software. The software version is displayed in the following format: [item-code-prefix][hipath-version][release-no][country-id][country-code][revision-no] e. g. P30252N 43 08 B 000 10ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.9.1.1.3
himSWVerOnProcItemCodeNoPrefixThis field contains the prefix of the software.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.9.1.1.4
himSWVerOnProcHP4KVerThis field contains the Hicom/HiPath version.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.9.1.1.5
himSWVerOnProcSysRelThis field contains the system release number.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.9.1.1.6
himSWVerOnProcCountryThis field contains the country identifier.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.9.1.1.7
himSWVerOnProcCountryCodeThis field contains the country encoding.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.9.1.1.8
himSWVerOnProcRevNoThis field contains the revision number of the ADP software.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.9.1.1.9
himSwPkgVersion
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.10
himSWPkgVerTableThis table contains the software versions of the service functions. This data is retrieved using the UNIX command pgkinfo -l.
SEQUENCE OF HimSWPkgVerEntry
.1.3.6.1.4.1.4329.2.51.10.1
himSWPkgVerEntry
HimSWPkgVerEntry
.1.3.6.1.4.1.4329.2.51.10.1.1
himSWPkgVerPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.10.1.1.1
himSWPkgVerPkgAbbrThis field contains the abbreviation of the software package.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.10.1.1.2
himSWPkgVerPkgNameThis field contains the name of the software package.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.10.1.1.3
himSWPkgVerVersionThis field contains the version of the software package.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.10.1.1.4
himSWPkgVerInstAtThis field contains the date on which the software package was installed.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.10.1.1.5
himSWPkgVerStatusThis field contains the status of the software package.ro
Enumeration
.1.3.6.1.4.1.4329.2.51.10.1.1.6
himSystem
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.11
himSysBasicTableThis table complements the information about the HiPath 4000 system that is stored in the hicomSystem branch of the hicom MIB.
SEQUENCE OF HimSysBasicEntry
.1.3.6.1.4.1.4329.2.51.11.1
himSysBasicEntry
HimSysBasicEntry
.1.3.6.1.4.1.4329.2.51.11.1.1
himSysBasicPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.11.1.1.1
himSysBasicDomainThis field contains the name of the domain to which the system is belonging.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.11.1.1.2
himSysBasicNodeNoHiPath node number. This field contains the globally unique number of your own PABX. This has a hierarchical structure containing different levels in Version V1.0 and later. Up to three values of the format: L2- L1- L0 can be used for numbering a system. - L2: area number in level 2 - L1: area number in level 1 - L0: area number in level 0 or node number in the old sense. If the value '0' is selected for a level, this means that the relevant hierarchical level is not being used for node numbering: '0' is equal to 'nothing' or 'level is not set'. With the help of this new node number format it is now possible to implement node numbers in networks in which - just as with dial numbers - the network hierarchy is reflected in the node numbers. The same numbering level (= number of levels set in the node number) must be used for all nodes in a network. This field will always show a three-level display with leading zeroes for levels not used for systems in Version V1.0 and later. Example: - 0-0-100 for 1-level numbering - 0-1-101 for 2-level numbering - 1-2-300 for 3-level numbering Values: 0-9 and '-' with format 22-111-000 Level 0 (000) 0-999 Level 1 (111) 0-253 Level 2 (22) 0-29 Max. 10 digitsro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.11.1.1.3
himSysBasicLEGKThis field tells if the 'LEGK' feature is activated on the system. LEGK is a process within the call processing of HiPath 4000 with the following functions: - Gate keeper function: IP address resolution mechanism for IP trunking requiring the HG3550 board as hardware. - Resource Management: This function monitors network component usage for controlling IP trunking, IPDA scenarios, HFA and direct media connections. The LEGK can be activated at every HiPath 4000 in the network. Alternatively, it can be configured on a specific HiPath 4000 system only.ro
HimYesNo
.1.3.6.1.4.1.4329.2.51.11.1.1.4
himSysLANCardsTable
SEQUENCE OF HimSysLANCardsEntry
.1.3.6.1.4.1.4329.2.51.11.2
himSysLANCardsEntry
HimSysLANCardsEntry
.1.3.6.1.4.1.4329.2.51.11.2.1
himSysLANCardsPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.11.2.1.1
himSysLANCardsIPAddrUnique IP address within the Customer LAN.ro
IpAddress
.1.3.6.1.4.1.4329.2.51.11.2.1.2
himSysLANCardsNetMaskThe netmask of the LAN card. It depends on the class of the LAN Card address.ro
IpAddress
.1.3.6.1.4.1.4329.2.51.11.2.1.3
himSysLANCardsBroadCastThe broadcast address is used to send a datagram packet to all hosts of a network or subnetwork, e.g. for address propagation from a router. The broadcast address also depends on the LAN Card address.ro
IpAddress
.1.3.6.1.4.1.4329.2.51.11.2.1.4
himSysLANCardsTypeType of the LAN card. Possible values are Ethernet and Token Ring.ro
Enumeration
.1.3.6.1.4.1.4329.2.51.11.2.1.5
himSysLANCardsStatusThe status of the configured LAN card. Can be one of the following: - Unknown (no traffic light lit): The LAN Card is configured, but no reboot has been performed. - Enabled (green traffic light lit): The LAN Card is active. - Disabled (red traffic light lit): The LAN Card is not active.ro
Enumeration
.1.3.6.1.4.1.4329.2.51.11.2.1.6
himSysHostsTable
SEQUENCE OF HimSysHostsEntry
.1.3.6.1.4.1.4329.2.51.11.3
himSysHostsEntry
HimSysHostsEntry
.1.3.6.1.4.1.4329.2.51.11.3.1
himSysHostsPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.11.3.1.1
himSysHostsNoIndex of the host entry.ro
Integer32
.1.3.6.1.4.1.4329.2.51.11.3.1.2
himSysHostsIPAddrThe IP address of the host.ro
IpAddress
.1.3.6.1.4.1.4329.2.51.11.3.1.3
himSysHostsNameUnique name of the host.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.11.3.1.4
himSysWAMLConn
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.11.4
himSysWAMLConnTable
SEQUENCE OF HimSysWAMLConnEntry
.1.3.6.1.4.1.4329.2.51.11.4.1
himSysWAMLConnEntry
HimSysWAMLConnEntry
.1.3.6.1.4.1.4329.2.51.11.4.1.1
himSysWAMLConnPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.11.4.1.1.1
himSysWAMLConnLTGLine/trunk group number. Valid values: 1-1ro
Integer32 (1)
.1.3.6.1.4.1.4329.2.51.11.4.1.1.2
himSysWAMLConnLTULine/trunk unit. Valid values: 1-15, for IP Gateway DSP HW of NCUI STMI STMA WAML 1-99, for RG/ACGEN PER DIU SIUP TMD 17-99, for NCUI STMA WAMLro
Integer32
.1.3.6.1.4.1.4329.2.51.11.4.1.1.3
himSysWAMLConnSlotSlot number of LTU (Line/Trunk Unit). Valid values: 1-121, for STMI, IP gateway, PER, RG, ACGEN, DIU, SIUP, TMD 1-145, for STMA, WAMLro
Integer32
.1.3.6.1.4.1.4329.2.51.11.4.1.1.4
himSysWAMLConnRufNrPhone number of the WAML board.ro
HimPhoneNumber
.1.3.6.1.4.1.4329.2.51.11.4.1.1.5
himSysWAMLConnBChlNumber of b-channels on the WAML board.ro
Unsigned32
.1.3.6.1.4.1.4329.2.51.11.4.1.1.6
himSysWAMLConnStatusStatus of the WAML board.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.11.4.1.1.7
himSysWAMLConnIPTable
SEQUENCE OF HimSysWAMLConnIPEntry
.1.3.6.1.4.1.4329.2.51.11.4.2
himSysWAMLConnIPEntry
HimSysWAMLConnIPEntry
.1.3.6.1.4.1.4329.2.51.11.4.2.1
himSysWAMLConnIPPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.11.4.2.1.1
himSysWAMLConnIPLTGLine/trunk group number. Valid values: 1-1ro
Integer32 (1)
.1.3.6.1.4.1.4329.2.51.11.4.2.1.2
himSysWAMLConnIPLTULine/trunk unit. Valid values: 1-15, for IP Gateway DSP HW of NCUI STMI STMA WAML 1-99, for RG/ACGEN PER DIU SIUP TMD 17-99, for NCUI STMA WAMLro
Integer32
.1.3.6.1.4.1.4329.2.51.11.4.2.1.3
himSysWAMLConnIPSlotSlot number of LTU (Line/Trunk Unit). Valid values: 1-121, for STMI, IP gateway, PER, RG, ACGEN, DIU, SIUP, TMD 1-145, for STMA, WAMLro
Integer32
.1.3.6.1.4.1.4329.2.51.11.4.2.1.4
himSysWAMLConnIPIfNameName of the interface.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.11.4.2.1.5
himSysWAMLConnIPAddrIP address of the WAML connection.ro
IpAddress
.1.3.6.1.4.1.4329.2.51.11.4.2.1.6
himSysWAMLConnIPNetMaskNet mask of the WAML connection.ro
IpAddress
.1.3.6.1.4.1.4329.2.51.11.4.2.1.7
himBoards
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.12
himBoardBasicTableThis table contains the boards that are managed by CM. It can be viewed as an extension of hicomBCSUTable. Please note that the PEN (LTG, LTU, Slot) of LTU boards is different from what is contained in CM, and uses the same format as in the hicom MIB.
SEQUENCE OF HimBoardBasicEntry
.1.3.6.1.4.1.4329.2.51.12.1
himBoardBasicEntry
HimBoardBasicEntry
.1.3.6.1.4.1.4329.2.51.12.1.1
himBoardBasicPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.12.1.1.1
himBoardBasicLTGLine/trunk group number. Valid values: 1-1ro
Integer32 (1)
.1.3.6.1.4.1.4329.2.51.12.1.1.2
himBoardBasicLTULine/trunk unit. Valid values: 1-15, for IP Gateway DSP HW of NCUI STMI STMA WAML 1-99, for RG/ACGEN PER DIU SIUP TMD 17-99, for NCUI STMA WAMLro
Integer32
.1.3.6.1.4.1.4329.2.51.12.1.1.3
himBoardBasicSlotSlot number of LTU (Line/Trunk Unit). Valid values: 1-121, for STMI, IP gateway, PER, RG, ACGEN, DIU, SIUP, TMD 1-145, for STMA, WAMLro
Integer32
.1.3.6.1.4.1.4329.2.51.12.1.1.4
himBoardBasicFuncIdFunction ID Valid values: 0-255 2 for SIU type 2 (MFV) 3 for SIU type 3 (MFC) 4 for SIU - RDS functionality 5 for SIU - ANI signaling 6 for SIU - CIS multifrequency (MFS) 7 for SIU - line testingro
Integer32
.1.3.6.1.4.1.4329.2.51.12.1.1.5
himBoardBasicCatCategory The board type includes: LTG -- line/trunk group LTU -- line/trunk unit PER -- peripheral module PERHW -- load peripheral hardware ACGEN -- alternating current generator DIU -- digital interface unit IPGW -- IP gateway RG -- ring generator SIUP -- signalling unit periphery TMD -- T1 boardsro
Enumeration
.1.3.6.1.4.1.4329.2.51.12.1.1.6
himBoardBasicNameName of the setup the board is configured to.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.12.1.1.7
himBoardBasicVOIPSecro
HimYesNo
.1.3.6.1.4.1.4329.2.51.12.1.1.8
himBoardBasicLWVarThe loadware variant. Default value: 0 Valid values: 0-9, A-Dro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.12.1.1.9
himBoardBasicNoCircNumber of circuits to be configured. Valid values: 1-255ro
Integer32
.1.3.6.1.4.1.4329.2.51.12.1.1.10
himBoardIPTableThis table contains the IP address configuration of the boards. Please note that not all fields are used for all boards.
SEQUENCE OF HimBoardIPEntry
.1.3.6.1.4.1.4329.2.51.12.2
himBoardIPEntry
HimBoardIPEntry
.1.3.6.1.4.1.4329.2.51.12.2.1
himBoardIPGwyIPAddrIP address of the gateway. Valid for: STMIro
IpAddress
.1.3.6.1.4.1.4329.2.51.12.2.1.1
himBoardIPSrcIPAddrSource IP address of STMI-HFA board. A valid Source IP address must always be specified in order to enable the IP phones to address the system (SWU) Default: 0.0.0.0 Valid for: HFAro
IpAddress
.1.3.6.1.4.1.4329.2.51.12.2.1.2
himBoardIPNetMaskIP network mask. Valid for: HFAro
IpAddress
.1.3.6.1.4.1.4329.2.51.12.2.1.3
himBoardIPDefRouterIP address of the default router within the LAN segment. The default router takes care of routing forward all packets with a destination address with a network part different from the own LAN segment. Default: 0.0.0.0 Valid for: HFAro
IpAddress
.1.3.6.1.4.1.4329.2.51.12.2.1.4
himBoardIPCustLANIPIP address of customer LAN. Default: 0.0.0.0 Valid for: IGW, SIPro
IpAddress
.1.3.6.1.4.1.4329.2.51.12.2.1.5
himBoardIPSTMI2IGWSubMaskIP subnet mask of LAN segment. Default: 0.0.0.0 Valid for: IGW, SIPro
IpAddress
.1.3.6.1.4.1.4329.2.51.12.2.1.6
himBoardIPDefGWIPDefault gateway IP address. Default: 0.0.0.0 Valid for: IGW, SIPro
IpAddress
.1.3.6.1.4.1.4329.2.51.12.2.1.7
himBoardIPManStatIPIP address of management station. Default: 0.0.0.0 Valid for: IGW, SIPro
IpAddress
.1.3.6.1.4.1.4329.2.51.12.2.1.8
himBoardIPManStatPortPort number of management station. Valid values: 1024 - 65535 Default: 0 Valid for: IGW, SIPro
Integer32
.1.3.6.1.4.1.4329.2.51.12.2.1.9
himBoardIPBckpServIPIP address of backup server. Default: 0.0.0.0 Valid for: IGW, SIPro
IpAddress
.1.3.6.1.4.1.4329.2.51.12.2.1.10
himBoardIPBckpServPortPort number of backup server. Default: 0 (0 means 'undefined port number') Valid for: IGW, SIPro
Integer32
.1.3.6.1.4.1.4329.2.51.12.2.1.11
himBoardLocTableThis table contains the location data of the boards. It is only available for boards of type DSX, LTUCA, LTUCE and LTUCX.
SEQUENCE OF HimBoardLocEntry
.1.3.6.1.4.1.4329.2.51.12.3
himBoardLocEntry
HimBoardLocEntry
.1.3.6.1.4.1.4329.2.51.12.3.1
himBoardLocIdDescribes the location of the switch for the system configurator. Valid values: 0-999ro
Integer32
.1.3.6.1.4.1.4329.2.51.12.3.1.1
himBoardLocLocPostal address of the LTU (Line/Trunk Unit) shelf. Applies to the Local Connection Type. Valid values: text, up to 45 charactersro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.12.3.1.2
himBoardLocPhoneNoPhone number at the shelf location. Valid values: 0-9, *, #, A-D, up to 22 charactersro
HimPhoneNumber
.1.3.6.1.4.1.4329.2.51.12.3.1.3
himBoardLocFaxNoFax number at the shelf location. Valid values: 0-9, *, #, A-D, up to 22 charactersro
HimPhoneNumber
.1.3.6.1.4.1.4329.2.51.12.3.1.4
himIPDA
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.13
himIPDAGenData
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.13.1
himIPDAGenTableGeneral settings that are true for all IPDAs.
SEQUENCE OF HimIPDAGenEntry
.1.3.6.1.4.1.4329.2.51.13.1.1
himIPDAGenEntry
HimIPDAGenEntry
.1.3.6.1.4.1.4329.2.51.13.1.1.1
himIPDAGenPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.13.1.1.1.1
himIPDAGenSpeedIndicates the bit-rate speed. Valid values: 10 Mbits/s; 100 Mbits/sro
Integer32 (10 | 100)
.1.3.6.1.4.1.4329.2.51.13.1.1.1.2
himIPDAGenModeIndicates the bit-rate mode. Valid values: Full Duplex, Half Duplexro
Enumeration
.1.3.6.1.4.1.4329.2.51.13.1.1.1.3
himIPDAGenPayConnTOS for VoIP payload connections to APs (CP). Valid values: 0-255ro
Integer32
.1.3.6.1.4.1.4329.2.51.13.1.1.1.4
himIPDAGenSigConnTOS for signalling connections to APs (FA). Valid values: 0-255ro
Integer32
.1.3.6.1.4.1.4329.2.51.13.1.1.1.5
himIPDAGenIPTableGeneral IP settings that are true for all IPDAs.
SEQUENCE OF HimIPDAGenIPEntry
.1.3.6.1.4.1.4329.2.51.13.1.2
himIPDAGenIPEntry
HimIPDAGenIPEntry
.1.3.6.1.4.1.4329.2.51.13.1.2.1
himIPDAGenIPNetAddrIP net address of HiPath LAN segment.ro
IpAddress
.1.3.6.1.4.1.4329.2.51.13.1.2.1.1
himIPDAGenIPNetMaskIP net mask of HiPath LAN segment.ro
IpAddress
.1.3.6.1.4.1.4329.2.51.13.1.2.1.2
himIPDAGenIPCCAAddrAddress of the CC-A processor within the HiPath LAN segment.ro
IpAddress
.1.3.6.1.4.1.4329.2.51.13.1.2.1.3
himIPDAGenIPCCBAddrAddress of the CC-B processor within the HiPath LAN segment. Default value: 0.0.0.0ro
IpAddress
.1.3.6.1.4.1.4329.2.51.13.1.2.1.4
himIPDAGenIPDefRoutAddrIP address of the default router within the HiPath LAN segment.ro
IpAddress
.1.3.6.1.4.1.4329.2.51.13.1.2.1.5
himIPDAGenIPSurvNetAddrThe IP address of the survivability net. Default value: 0.0.0.0ro
IpAddress
.1.3.6.1.4.1.4329.2.51.13.1.2.1.6
himIPDAAPData
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.13.2
himIPDABasicTableThis table stores IPDA information from CM.
SEQUENCE OF HimIPDABasicEntry
.1.3.6.1.4.1.4329.2.51.13.2.1
himIPDABasicEntry
HimIPDABasicEntry
.1.3.6.1.4.1.4329.2.51.13.2.1.1
himIPDABasicPabxIdro
HimPabxId
.1.3.6.1.4.1.4329.2.51.13.2.1.1.1
himIPDABasicLTULine/trunk unit. Valid values: 17-99ro
Integer32
.1.3.6.1.4.1.4329.2.51.13.2.1.1.2
himIPDABasicConnTypeConnection type of the shelf. Valid values: APDL -- AP shelf via IP - direct linked APNW -- AP shelf via IP - networkro
HimShelfNWType (0 | 3..4)
.1.3.6.1.4.1.4329.2.51.13.2.1.1.3
himIPDABasicBChanNoAmount of B-Channels. Valid values: 1- 120ro
Integer32
.1.3.6.1.4.1.4329.2.51.13.2.1.1.4
himIPDABasicConvAMLawro
HimYesNo
.1.3.6.1.4.1.4329.2.51.13.2.1.1.5
himIPDAIPTableThis table contains the IP address configuration of the IPDAs.
SEQUENCE OF HimIPDAIPEntry
.1.3.6.1.4.1.4329.2.51.13.2.2
himIPDAIPEntry
HimIPDAIPEntry
.1.3.6.1.4.1.4329.2.51.13.2.2.1
himIPDAIPAccPtAddrIP address of the access point in the AP network.ro
IpAddress
.1.3.6.1.4.1.4329.2.51.13.2.2.1.1
himIPDAIPTAccPtAddrIP address for the TAP/Service PC link at the access point. This IP address must be in the same network as the access point in the AP network.ro
IpAddress
.1.3.6.1.4.1.4329.2.51.13.2.2.1.2
himIPDAIPAccPtRoutAddrIP address of the gateway (IP address of the router in the AP network).ro
IpAddress
.1.3.6.1.4.1.4329.2.51.13.2.2.1.3
himIPDAIPNetMaskNWNetmask of the network to which the respective Access Point in AP network belongs.ro
IpAddress
.1.3.6.1.4.1.4329.2.51.13.2.2.1.4
himIPDAIPAccPtPriRoutAddrIP address of the primary signalling router for NCUI board (IP address of the router in the HiPath 4000 LAN segment). Required if the connection type is APDL.ro
IpAddress
.1.3.6.1.4.1.4329.2.51.13.2.2.1.5
himIPDAIPNetMaskDLNetmask of the network to which the Access Point in AP internal network belongs.ro
IpAddress
.1.3.6.1.4.1.4329.2.51.13.2.2.1.6
himIPDALocTableThis table contains the location data of the boards. It is only available for boards of type DSX, LTUCA, LTUCE and LTUCX.
SEQUENCE OF HimIPDALocEntry
.1.3.6.1.4.1.4329.2.51.13.2.3
himIPDALocEntry
HimIPDALocEntry
.1.3.6.1.4.1.4329.2.51.13.2.3.1
himIPDALocIdDescribes the location of the switch for the system configurator. Valid values: 0-999ro
Integer32
.1.3.6.1.4.1.4329.2.51.13.2.3.1.1
himIPDALocLocPostal address of the LTU (Line/Trunk Unit) shelf. Applies to the Local Connection Type. Valid values: text, up to 45 charactersro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.13.2.3.1.2
himIPDALocPhoneNoPhone number at the shelf location. Valid values: 0-9, *, #, A-D, up to 22 charactersro
HimPhoneNumber
.1.3.6.1.4.1.4329.2.51.13.2.3.1.3
himIPDALocFaxNoFax number at the shelf location. Valid values: 0-9, *, #, A-D, up to 22 charactersro
HimPhoneNumber
.1.3.6.1.4.1.4329.2.51.13.2.3.1.4
himInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.14
himSubagentLastMsgNoThe last message, warning or error number issued by the Him subagent.ro
Integer32
.1.3.6.1.4.1.4329.2.51.14.1
himSubagentLastMsgTextThe last message, warning or error text issued by the Him subagent.ro
OCTET STRING
.1.3.6.1.4.1.4329.2.51.14.2
himResultDataIs used for agent internal communication. Contains the PabxId of a Hicom for which the last discovery process was conveyed. Is SET by the discovery agent and indicates the availability of new discovered data. The new data is to be incorporated by the subagent into the subagent's data base.rw
Integer32
.1.3.6.1.4.1.4329.2.51.14.3
himDiscovery
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.15
himChangesIndicates the number of finished HIM discoveries - corresponds to the number of hicomHWDiscovXXX traps sent out.ro
Counter32
.1.3.6.1.4.1.4329.2.51.15.1
himDiscovTableThe table describing the status concerning discovery of HIM information.
SEQUENCE OF HimDiscovEntry
.1.3.6.1.4.1.4329.2.51.15.2
himDiscovEntryThe entry describes the status of the discovery process. It is designed to comply with the structure of discovery entries in the hicom MIB, even though data is only provided for one switch.
HimDiscovEntry
.1.3.6.1.4.1.4329.2.51.15.2.1
himDiscovPabxIdUnique identifier of the Hicom being discovered.ro
HimPabxId
.1.3.6.1.4.1.4329.2.51.15.2.1.1
himDiscovPabxMnemonicName of the Hicom system.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4329.2.51.15.2.1.2
himDiscovStatusStatus of discovery process. A managment station may initiate a discovery by setting this variable to value busy. The other values are set by the agent.rw
DiscoveryStates
.1.3.6.1.4.1.4329.2.51.15.2.1.3
himDiscovModeMode of discovery process.rw
DiscoveryModes
.1.3.6.1.4.1.4329.2.51.15.2.1.4
himDiscovTimDatDate and time (year, month, day, hour, minute, second) the last successful discovery action was performed for the Hicom.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4329.2.51.15.2.1.5
himDiscovErrTimDatDate and time (year, month, day, hour, minute, second) the last failed discovery action was performed for the Hicom.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4329.2.51.15.2.1.6
himMibConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.20
himMibGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.20.1
himWelcomePageGroup
Unknown
.1.3.6.1.4.1.4329.2.51.20.1.1
himSwitchDataGroup
Unknown
.1.3.6.1.4.1.4329.2.51.20.1.2
himSpecGroup
Unknown
.1.3.6.1.4.1.4329.2.51.20.1.3
himSWUPeripheryGroup
Unknown
.1.3.6.1.4.1.4329.2.51.20.1.4
himCentralSwitchGroup
Unknown
.1.3.6.1.4.1.4329.2.51.20.1.5
himGeneralSwitchGroup
Unknown
.1.3.6.1.4.1.4329.2.51.20.1.6
himFeaturesGroup
Unknown
.1.3.6.1.4.1.4329.2.51.20.1.7
himAPSPatchesGroup
Unknown
.1.3.6.1.4.1.4329.2.51.20.1.8
himSWVersionGroup
Unknown
.1.3.6.1.4.1.4329.2.51.20.1.9
himSWPkgVersionGroup
Unknown
.1.3.6.1.4.1.4329.2.51.20.1.10
himSystemGroup
Unknown
.1.3.6.1.4.1.4329.2.51.20.1.11
himBoardsGroup
Unknown
.1.3.6.1.4.1.4329.2.51.20.1.12
himIPDAGroup
Unknown
.1.3.6.1.4.1.4329.2.51.20.1.13
himInfoGroup
Unknown
.1.3.6.1.4.1.4329.2.51.20.1.14
himDiscoveryGroup
Unknown
.1.3.6.1.4.1.4329.2.51.20.1.15
himTrapsGroup
Unknown
.1.3.6.1.4.1.4329.2.51.20.1.16
himTrapGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.21
himTrapVariables
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.21.1
himTrapPabxIdUnique identifier of a Hicom system.
Integer32
.1.3.6.1.4.1.4329.2.51.21.1.1
himTrapPabxMnemonicMnemonic name of the Hicom system.
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.4329.2.51.21.1.2
himTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.4329.2.51.21.2
internalMessageHimSubagentAn internalMessage trap contains an informational message generated by the subagent.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4329.2.51.21.2.0
internalWarningHimSubagentAn internalWarning trap contains a warning message generated by a subagent.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4329.2.51.21.2.1
internalErrorHimSubagentAn internalError trap contains an error message generated by a subagent. After issuing this trap, the agent terminates.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4329.2.51.21.2.2
himDiscovSuccA himDiscovSucc trap indicates the successful termination of a discovery process.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4329.2.51.21.2.10
himDiscovErrA himDiscovErr trap signifies the unsuccessful termination of a discovery process.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4329.2.51.21.2.11
himDiscovBusyA himDiscovBusy trap signifies that a sw discovery process is running.
NOTIFICATION-TYPE
.1.3.6.1.4.1.4329.2.51.21.2.19
SIEMENS-HP4KHIM-MIB - SNMP MIB Reference | MIBs Explorer