Home/Catalog/SCA-X25EXT-MIB

SCA-X25EXT-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for SCA-X25EXT-MIB.

13
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

13 total
Object Name
x25ext
OBJECT IDENTIFIER
.1.3.6.1.4.1.208.51
SCANET-MIB
Unknown
.1.3.6.1.4.1.208.51
x25extCircuit
OBJECT IDENTIFIER
.1.3.6.1.4.1.208.51.1
x25extCircuitTable
SEQUENCE OF X25extCircuitEntry
.1.3.6.1.4.1.208.51.1.1
x25extCircuitEntry
X25extCircuitEntry
.1.3.6.1.4.1.208.51.1.1.1
x25extCircuitIndexro
IfIndexType
.1.3.6.1.4.1.208.51.1.1.1.1
x25extCircuitChannelro
INTEGER
.1.3.6.1.4.1.208.51.1.1.1.2
x25extCircuitLogicalIndexro
IfIndexType
.1.3.6.1.4.1.208.51.1.1.1.3
x25extCircuitPacketSizero
INTEGER
.1.3.6.1.4.1.208.51.1.1.1.4
x25extCircuitWindowSizero
INTEGER
.1.3.6.1.4.1.208.51.1.1.1.5
x25extCircuitTimeoutro
INTEGER
.1.3.6.1.4.1.208.51.1.1.1.6
x25extCircuitOutResetsro
Counter
.1.3.6.1.4.1.208.51.1.1.1.7
x25extCircuitOutFlowStuckResetsro
Counter
.1.3.6.1.4.1.208.51.1.1.1.8

SCA-X25EXT-MIB Technical Reference Overview

The SCA-X25EXT-MIB SNMP MIB module published by Scanet defines 13 managed OID objects, including 9 scalar/column metrics, 1 SNMP tables, and 0 trap/notification events. Key tabular structures include x25extCircuitTable.

Key OID Definitions in SCA-X25EXT-MIB

x25extCircuitTableSEQUENCEnot-accessible
.1.3.6.1.4.1.208.51.1.1

These objects contain general information about a specific circuit of an X.25 PLE.

x25extCircuitEntryX25extCircuitEntrynot-accessible
.1.3.6.1.4.1.208.51.1.1.1

Entries of x25extCircuitTable.

x25extCircuitIndexIfIndexTyperead-only
.1.3.6.1.4.1.208.51.1.1.1.1

The ifIndex value for the X.25 PLE Interface.

x25extCircuitChannelINTEGERread-only
.1.3.6.1.4.1.208.51.1.1.1.2

The channel number for this circuit.

x25extCircuitLogicalIndexIfIndexTyperead-only
.1.3.6.1.4.1.208.51.1.1.1.3

The ifIndex for a virtual ifEntry accociatedwith this circuit. The same as x25extCircuitIndex if no ifEntry is associated with the circuit.

x25extCircuitPacketSizeINTEGERread-only
.1.3.6.1.4.1.208.51.1.1.1.4

The packet size in octets used by this circuit.

x25extCircuitWindowSizeINTEGERread-only
.1.3.6.1.4.1.208.51.1.1.1.5

The window size used by this circuit.

x25extCircuitTimeoutINTEGERread-only
.1.3.6.1.4.1.208.51.1.1.1.6

Seconds left before timeout of the current state. If a call request is sent but no reply received x25extCircuitTimeout will show how many seconds remains before the call request is retransmitted. If the link is up but the current window is 0 x25extCircuitTimeout will show how many seconds remains before the link is reset and x25extCircuitOutFlowStuckResets is incremented.

x25extCircuitOutResetsCounterread-only
.1.3.6.1.4.1.208.51.1.1.1.7

Total number of resets sent on this circuit.

x25extCircuitOutFlowStuckResetsCounterread-only
.1.3.6.1.4.1.208.51.1.1.1.8

Number of resets sent on this circuit because the remote end did not acknoledge packets for a long time.

More MIBs from Scanet

Browse all ScanetMIBs →