Standard SNMP MIB module defining data structures for RITTAL-CMC-TC-MIB.

271
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

271 total
Object Name
rittal
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606
RFC1213-MIB
Unknown
.1.3.6.1.4.1.2606
cmcTc
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4
alarmSensorUnit1Alarm of sensor unit 1
TRAP-TYPE
.1.3.6.1.4.1.2606.4.0.1
alarmSensorUnit2Alarm of sensor unit 2
TRAP-TYPE
.1.3.6.1.4.1.2606.4.0.2
alarmSensorUnit3Alarm of sensor unit 3
TRAP-TYPE
.1.3.6.1.4.1.2606.4.0.3
alarmSensorUnit4Alarm of sensor unit 4
TRAP-TYPE
.1.3.6.1.4.1.2606.4.0.4
alarmUnit1Alarm of unit 1
TRAP-TYPE
.1.3.6.1.4.1.2606.4.0.5
alarmUnit2Alarm of unit 2
TRAP-TYPE
.1.3.6.1.4.1.2606.4.0.6
alarmUnit3Alarm of unit 3
TRAP-TYPE
.1.3.6.1.4.1.2606.4.0.7
alarmUnit4Alarm of unit 4
TRAP-TYPE
.1.3.6.1.4.1.2606.4.0.8
alarmValuesAlarm of values measured by external card
TRAP-TYPE
.1.3.6.1.4.1.2606.4.0.9
configChangedThe configuration of the cmc has changed, this trap is send if new setup is saved. Configuration can be changed by Terminal, Telnet, Web or SNMP *** NOT IMPLEMENTED ***
TRAP-TYPE
.1.3.6.1.4.1.2606.4.0.10
cmcTcMibRev
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.1
cmcTcMibMajRevThe Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information, correct interpretation of data may require a MIB document with the same major revision level.ro
INTEGER
.1.3.6.1.4.1.2606.4.1.1
cmcTcMibMinRevThe Minor Revision level. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred.ro
INTEGER
.1.3.6.1.4.1.2606.4.1.2
cmcTcMibConditionThe overall condition (status) of the system represented by this MIB. (2) OK (3) a minor problem, warning condition (yellow LED on CMC) (4) a major problem (red LED on CMC) (5) configuration of sensor units changed or unit detected (red/yellow/green LED on CMC)ro
Enumeration
.1.3.6.1.4.1.2606.4.1.3
cmcTcStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.2
cmcTcStatusDeviceCMCGeneral Status of CMC-TC unit itself (1) failed (2) OKro
Enumeration
.1.3.6.1.4.1.2606.4.2.1
cmcTcUnitsConnectedNumber of sensor units connected to the CMC, Port 1 to 4ro
INTEGER
.1.3.6.1.4.1.2606.4.2.2
cmcTcStatusSensorUnit1
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.2.3
cmcTcUnit1TypeOfDeviceType of sensor unit connected to port 1ro
Enumeration
.1.3.6.1.4.1.2606.4.2.3.1
cmcTcUnit1TextDescriptional text for sensor unit connected to port 1rw
DisplayString
.1.3.6.1.4.1.2606.4.2.3.2
cmcTcUnit1SerialSerialnumber of sensor unit connected to port 1ro
INTEGER
.1.3.6.1.4.1.2606.4.2.3.3
cmcTcUnit1StatusGeneral Status sensor unit connected to port 1 (1) OK (2) error, e. g. value overflow (3) configuration of sensor unit has changed, confirmation required (4) Quit from sensor unit to confirm configuration changes (5) timeout of sensor unit, confirmation required to unload this unit (6) sensor unit detected, needs to be confirmed (7) unit is not available (8) supply voltage is too low (9) Firmware upgrade runningro
Enumeration
.1.3.6.1.4.1.2606.4.2.3.4
cmcTcStatusUnit1Sensors
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.2.3.5
cmcTcUnit1NumberOfSensorsNumber of sensors connected to sensor unit 1ro
INTEGER
.1.3.6.1.4.1.2606.4.2.3.5.1
cmcTcUnit1SensorTableHeadline of sensor table
SEQUENCE OF CmcTcUnit1SensorEntry
.1.3.6.1.4.1.2606.4.2.3.5.2
cmcTcUnit1SensorEntryEntries of sensor table
CmcTcUnit1SensorEntry
.1.3.6.1.4.1.2606.4.2.3.5.2.1
unit1SensorIndexIndex for the list of value entries. Its value ranges between 1 and the value of cmcTcUnit1NumberOfSensors.ro
INTEGER
.1.3.6.1.4.1.2606.4.2.3.5.2.1.1
unit1SensorTypeType of sensor which is connected to sensor unit 1 to sensor[unit1SensorIndex] 1: no sensor connected 2: sensor failure 3: value overflow 4: sensor type 1, access sensor 5: sensor type 2, vibration sensor 6: sensor type 3, motion sensor 7: sensor type 4, smoke sensor 8: sensor type 5, air flow sensor 9: sensor type 6, reserved 10: sensor type 7, temperature sensor 11: sensor type 8, 4..20mA sensor 12: sensor type 9, humidity sensor 13: user sensor with normally opened contact 14: user sensor with normally closed contact 15: door locked sensor from locking device 16: remote unlock sensor (e.g. external keypad) 17: voltage sensor, indicates status of main voltage (OK, NOK) 18: voltage value 19: fan status, from CMC-TC-FAS-Unit 20: cardreader or keypad, connected to I2C port 21: duty cycle of fan, FCS-Unit 22: status of fan, FCS-Unit 23: leakage sensor 24: warning, RittalTopTherm(RTT)-Unit 25: alarm, RittalTopTherm-Unit 26: temperature difference filter monitor, RTT-Unit 27: heatflow RCT-Unit 28: alarm RCT-Unit 29: warning RCT-Unit 30: actual current*10, PSM-Unit 31: status PSM-Unit 32: position PSM-Unit, normal/reversed = circuit 1/2 33: air Flap 34: acoustic sensor 35: DET-AC fault (extinguisher) 36: DET-AC first alarm (extinguisher) 37: DET-AC main alarm (extinguisher) 38: DRC: RFID Tag 40-47: RPM Fan 1.1 - Fan 4.2, LCP 48-55: Air temperature 1.1 - 4.2, LCP 56,57: actual temperature 1,2, LCP 58: water inlet temperature, LCP 59: water outlet temperature, LCP 60: water flow 61: fan speed (desired value) 62: status valve, LCP 63: status LCP 64: temperature difference water temperatures 65: control temperature 1, LCP 66: control temperature 2, LCP 67: condensate pump, duration, LCP 68: condensate pump, cycles, LCP 72: total energy*10 (kWh), PSM 73: total power*10 (kW), PSM 74: frequency*10 (Hz), PSM 75: voltage*10 (V), PSM 76: voltage status, PSM 77: current*10 (A), PSM 78: current status, PSM 79: power*10 (kW) per phase, PSM 80: energy*10 (kWh) per phase, PSM 81: temporary energy*10 (kWh) per phase, PSM 100: temperature sensor, wireless 101: temperature sensor (combi), wireless 102: humidity sensor, wireless 103: access sensor, wireless 104: user sensor with normally opened contact, wireless 105: user sensor with normally closed contact, wireless 106: analog sensor 4..20mA, wirelessro
Enumeration
.1.3.6.1.4.1.2606.4.2.3.5.2.1.2
unit1SensorTextDescriptional text for each sensor (entry in the table)rw
DisplayString
.1.3.6.1.4.1.2606.4.2.3.5.2.1.3
unit1SensorStatusActual status of the sensorro
Enumeration
.1.3.6.1.4.1.2606.4.2.3.5.2.1.4
unit1SensorValueValue of sensorro
INTEGER
.1.3.6.1.4.1.2606.4.2.3.5.2.1.5
unit1SensorSetHighValue for high setpoint of sensorrw
INTEGER
.1.3.6.1.4.1.2606.4.2.3.5.2.1.6
unit1SensorSetLowValue for low setpoint of sensor, also used as alarm delayrw
INTEGER
.1.3.6.1.4.1.2606.4.2.3.5.2.1.7
unit1SensorSetWarnValue for warning setpoint of sensor, also used as fan thresholdrw
INTEGER
.1.3.6.1.4.1.2606.4.2.3.5.2.1.8
unit1SensorHysteresis% -Value for hysteresis for High, Low and Warning, input in % from actual setpointrw
INTEGER
.1.3.6.1.4.1.2606.4.2.3.5.2.1.9
unit1SensorDisplayFactorFactor of sensor value and setpoints, devide actual value with this value, e. g. factor = 10: sensor value = 100, actual value = 10.0ro
INTEGER
.1.3.6.1.4.1.2606.4.2.3.5.2.1.10
unit1SensorScaleStartValue for start value for scaling of 0..100% (4..20mA) sensor, example: acutal range of value of 4..20mA sensor is from 10 to 60A, then this variable is set to 10, also valid for setpointsrw
INTEGER
.1.3.6.1.4.1.2606.4.2.3.5.2.1.11
unit1SensorScaleEndValue for end value for scaling of 0..100% (4..20mA) sensor, example: acutal range of value of 4..20mA sensor is from 10 to 60A, then this variable is set to 60, also valid for setpointsrw
INTEGER
.1.3.6.1.4.1.2606.4.2.3.5.2.1.12
unit1SensorUnitUnit for 0..100% (4..20mA) sensor, example: acutal range of value of 4..20mA sensor is from 10 to 60A, then this variable is set to 'A'rw
DisplayString
.1.3.6.1.4.1.2606.4.2.3.5.2.1.13
unit1SensorInfoAdditional information to the sensor, e. g. Serialnumber, Signal Quality..ro
DisplayString
.1.3.6.1.4.1.2606.4.2.3.5.2.1.14
cmcTcStatusUnit1Outputs
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.2.3.6
cmcTcUnit1NumberOfOutputsNumber of outputs available on sensor unit 1ro
INTEGER
.1.3.6.1.4.1.2606.4.2.3.6.1
cmcTcUnit1OutputTableHeadline of output table
SEQUENCE OF CmcTcUnit1OutputEntry
.1.3.6.1.4.1.2606.4.2.3.6.2
cmcTcUnit1OutputEntryEntries of output table
CmcTcUnit1OutputEntry
.1.3.6.1.4.1.2606.4.2.3.6.2.1
unit1OutputIndexIndex for the list of output entries. Its value ranges between 1 and the value of cmcTcUnit1NumberOfOutputs.ro
INTEGER
.1.3.6.1.4.1.2606.4.2.3.6.2.1.1
unit1OutputTypeType of output which is connected to sensor unit 1 to output[unit1OutputIndex] 1: no output connected 2: output failure 3: value overflow 4: output type 1, door locking TS8,Ergoform 5: output type 2, universal lock 1, lock with power 6: output type 3, universal lock 2, unlock with power 7: output type 4, fan relay 8: output type 5, fan controlled 9: output type 6, universal relay output 10: output type 7, room door lock 11: output type 8, power output 12: output type 9, door lock with Master key 13: output type 10, door lock FR(i) 14: setpoint (FCS, LCP) 15: setpoint temperature monitoring (LCP) 16: hysteresis of setpoint (LCP) 17: command for remote control of RCT 18: relay PSM, 1=On, 0=Off 19: high setpoint current monitoring PSM 20: low setpoint current monitoring PSM 21: setpoint temperature RTT 22: setpoint temperature monitoring RTT 23: power output 20A 24: door magnet (automatic door release) 30: control mode, LCP 31: min fan speed (fan control), LCP 32: min delta T (fan control), LCP 33: max delta T (fan control), LCP 34: PID controller, KP, LCP 35: PID controller, KI, LCP 36 PID controller, KD, LCP 37 flowrate flowmeter, LCP 38: cw value of water (default: 4187), LCP 39: deltaT, LCP 40: control mode, LCP 42: setpoint high voltage PSM 43: setpoint low voltage PSM 44: setpoint high current PSM 45: setpoint low current PSM 46: command PSMro
Enumeration
.1.3.6.1.4.1.2606.4.2.3.6.2.1.2
unit1OutputTextDescriptional text for each output (entry in the table)rw
DisplayString
.1.3.6.1.4.1.2606.4.2.3.6.2.1.3
unit1OutputStatusActual status of the outputrw
Enumeration
.1.3.6.1.4.1.2606.4.2.3.6.2.1.4
unit1OutputValueValue for outputrw
INTEGER
.1.3.6.1.4.1.2606.4.2.3.6.2.1.5
unit1OutputSetCommand for outputrw
Enumeration
.1.3.6.1.4.1.2606.4.2.3.6.2.1.6
unit1OutputConfigConfiguration for output 1: disable remote control (e.g. keypad) 2: enable remote controlrw
Enumeration
.1.3.6.1.4.1.2606.4.2.3.6.2.1.7
unit1OutputDelayUnsigned Value for delay, after this time the output will fall into the previous staterw
INTEGER
.1.3.6.1.4.1.2606.4.2.3.6.2.1.8
unit1OutputTimeoutActionState for output if timeout (RS422) occursrw
Enumeration
.1.3.6.1.4.1.2606.4.2.3.6.2.1.9
cmcTcStatusUnit1Msg
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.2.3.7
cmcTcUnit1NumberOfMsgsNumber of messages that can be created with sensor unit 1ro
INTEGER
.1.3.6.1.4.1.2606.4.2.3.7.1
cmcTcUnit1MsgTableHeadline of message table
SEQUENCE OF CmcTcUnit1MsgEntry
.1.3.6.1.4.1.2606.4.2.3.7.2
cmcTcUnit1MsgEntryEntries of message table
CmcTcUnit1MsgEntry
.1.3.6.1.4.1.2606.4.2.3.7.2.1
unit1MsgIndexIndex for the list of message entries. Its value ranges between 1 and the value of cmcTcUnit1NumberOfMsgs.ro
INTEGER
.1.3.6.1.4.1.2606.4.2.3.7.2.1.1
unit1MsgTextDescriptional text for each message (entry in the table)rw
DisplayString
.1.3.6.1.4.1.2606.4.2.3.7.2.1.2
unit1MsgStatusActual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to OFF 10: output is set to ON 11: door is open 12: door is closed 13: door is locked 14: door is unlocked by remote input, e.g. external cardreader 15: door is unlocked by reader or keypad connected to I2C 16: door is unlocked by SNMP set command (unit1OutputSet) 17: door is unlocked by WEB 18: door is unlocked by timer 19: no access, wrong keycode or cardnumber 20: orientation of PSM-Unit is circuit 1 21: orientation of PSM-Unit is circuit 2 22: battery low, wireless sensorro
Enumeration
.1.3.6.1.4.1.2606.4.2.3.7.2.1.3
unit1MsgRelaySetup of Alarm relay for this message/alarm 1: no switching of alarm relay 2: switching of alarm relayrw
Enumeration
.1.3.6.1.4.1.2606.4.2.3.7.2.1.4
unit1MsgBeeperSetup of Alarm beeper for this alarm 1: no audible alarm 2: audible alarmrw
Enumeration
.1.3.6.1.4.1.2606.4.2.3.7.2.1.5
unit1MsgTrap1Trap receiver 1 activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.3.7.2.1.6
unit1MsgTrap2Trap receiver 2 activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.3.7.2.1.7
unit1MsgTrap3Trap receiver 3 activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.3.7.2.1.8
unit1MsgTrap4Trap receiver 4 and Event Logging activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.3.7.2.1.9
unit1MsgQuitReset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' keyrw
Enumeration
.1.3.6.1.4.1.2606.4.2.3.7.2.1.10
unit1MsgDelayDelay of alarm conditionrw
INTEGER
.1.3.6.1.4.1.2606.4.2.3.7.2.1.11
cmcTcStatusSensorUnit2
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.2.4
cmcTcUnit2TypeOfDeviceType of sensor unit connected to port 2ro
Enumeration
.1.3.6.1.4.1.2606.4.2.4.1
cmcTcUnit2TextDescriptional text for sensor unit connected to port 2rw
DisplayString
.1.3.6.1.4.1.2606.4.2.4.2
cmcTcUnit2SerialSerialnumber of sensor unit connected to port 2ro
INTEGER
.1.3.6.1.4.1.2606.4.2.4.3
cmcTcUnit2StatusGeneral Status sensor unit connected to port 2 (1) OK (2) error (3) configuration of sensor unit has changed, confirmation required (4) Quit from sensor unit to confirm configuration changes (5) timeout of sensor unit, confirmation required (6) sensor unit detected, needs to be confirmed (8) supply voltage is too low (9) Firmware upgrade runningro
Enumeration
.1.3.6.1.4.1.2606.4.2.4.4
cmcTcStatusUnit2Sensors
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.2.4.5
cmcTcUnit2NumberOfSensorsNumber of sensors connected to sensor unit 2ro
INTEGER
.1.3.6.1.4.1.2606.4.2.4.5.1
cmcTcUnit2SensorTableHeadline of sensor table
SEQUENCE OF CmcTcUnit2SensorEntry
.1.3.6.1.4.1.2606.4.2.4.5.2
cmcTcUnit2SensorEntryEntries of sensor table
CmcTcUnit2SensorEntry
.1.3.6.1.4.1.2606.4.2.4.5.2.1
unit2SensorIndexIndex for the list of value entries. Its value ranges between 1 and the value of cmcTcUnit2NumberOfSensors.ro
INTEGER
.1.3.6.1.4.1.2606.4.2.4.5.2.1.1
unit2SensorTypeType of sensor which is connected to sensor unit 2 to sensor[unit2SensorIndex] 1: no sensor connected 2: sensor failure 3: value overflow 4: sensor type 1, access sensor 5: sensor type 2, vibration sensor 6: sensor type 3, motion sensor 7: sensor type 4, smoke sensor 8: sensor type 5, air flow sensor 9: sensor type 6, reserved 10: sensor type 7, temperature sensor 11: sensor type 8, 4..20mA sensor 12: sensor type 9, humidity sensor 13: user sensor with normally opened contact 14: user sensor with normally closed contact 15: door locked sensor from locking device 16: remote unlock sensor (e.g. external keypad) 17: voltage sensor, indicates status of main voltage 18: voltage value 19: fan status 20: cardreader or keypad, connected to I2C port 21: duty cycle of fan, FCS-Unit 22: status of fan, FCS-Unit 23: leakage sensor 24: warning, RittalTopTherm(RTT)-Unit 25: alarm, RittalTopTherm-Unit 26: temperature difference filter monitor, RTT-Unit 27: heatflow RCT-Unit 28: alarm RCT-Unit 29: warning RCT-Unit 30: actual current*10, PSM-Unit 31: status PSM-Unit 32: position PSM-Unit, normal/reversed = circuit 1/2 33: air Flap 34: acoustic sensor 35: DET-AC fault (extinguisher) 36: DET-AC first alarm (extinguisher) 37: DET-AC main alarm (extinguisher) 38: DRC: RFID Tag 40-47: RPM Fan 1.1 - Fan 4.2, LCP 48-55: Air temperature 1.1 - 4.2, LCP 56,57: actual temperature 1,2, LCP 58: water inlet temperature, LCP 59: water outlet temperature, LCP 60: water flow 61: fan speed (desired value) 62: status valve, LCP 63: status LCP 64: temperature difference water temperatures 65: control temperature 1, LCP 66: control temperature 2, LCP 67: condensate pump, duration, LCP 68: condensate pump, cycles, LCP 72: total energy*10 (kWh), PSM 73: total power*10 (kW), PSM 74: frequency*10 (Hz), PSM 75: voltage*10 (V), PSM 76: voltage status, PSM 77: current*10 (A), PSM 78: current status, PSM 79: power*10 (kW) per phase, PSM 80: energy*10 (kWh) per phase, PSM 81: temporary energy*10 (kWh) per phase, PSM 100: temperature sensor, wireless 101: temperature sensor (combi), wireless 102: humidity sensor, wireless 103: access sensor, wireless 104: user sensor with normally opened contact, wireless 105: user sensor with normally closed contact, wireless 106: analog sensor 4..20mA, wirelessro
Enumeration
.1.3.6.1.4.1.2606.4.2.4.5.2.1.2
unit2SensorTextDescriptional text for each sensor (entry in the table)rw
DisplayString
.1.3.6.1.4.1.2606.4.2.4.5.2.1.3
unit2SensorStatusActual status of the sensorro
Enumeration
.1.3.6.1.4.1.2606.4.2.4.5.2.1.4
unit2SensorValueValue of sensorro
INTEGER
.1.3.6.1.4.1.2606.4.2.4.5.2.1.5
unit2SensorSetHighValue for high setpoint of sensorrw
INTEGER
.1.3.6.1.4.1.2606.4.2.4.5.2.1.6
unit2SensorSetLowValue for low setpoint of sensor, also used as alarm delayrw
INTEGER
.1.3.6.1.4.1.2606.4.2.4.5.2.1.7
unit2SensorSetWarnValue for warning setpoint of sensor, also used as fan thresholdrw
INTEGER
.1.3.6.1.4.1.2606.4.2.4.5.2.1.8
unit2SensorHysteresis% -Value for hysteresis for High, Low and Warning, input in % from actual setpointrw
INTEGER
.1.3.6.1.4.1.2606.4.2.4.5.2.1.9
unit2SensorDisplayFactorFactor of sensor value and setpoints, devide actual value with this value, e. g. factor = 10: sensor value = 100, actual value = 10.0ro
INTEGER
.1.3.6.1.4.1.2606.4.2.4.5.2.1.10
unit2SensorScaleStartValue for start value for scaling of 0..100% (4..20mA) sensor, example: acutal range of value of 4..20mA sensor is from 10 to 60A, then this variable is set to 10, also valid for setpointsrw
INTEGER
.1.3.6.1.4.1.2606.4.2.4.5.2.1.11
unit2SensorScaleEndValue for end value for scaling of 0..100% (4..20mA) sensor, example: acutal range of value of 4..20mA sensor is from 10 to 60A, then this variable is set to 60, also valid for setpointsrw
INTEGER
.1.3.6.1.4.1.2606.4.2.4.5.2.1.12
unit2SensorUnitUnit for 0..100% (4..20mA) sensor, example: acutal range of value of 4..20mA sensor is from 10 to 60A, then this variable is set to 'A'rw
DisplayString
.1.3.6.1.4.1.2606.4.2.4.5.2.1.13
unit2SensorInfoAdditional information to the sensor, e. g. Serialnumber, Signal Quality..ro
DisplayString
.1.3.6.1.4.1.2606.4.2.4.5.2.1.14
cmcTcStatusUnit2Outputs
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.2.4.6
cmcTcUnit2NumberOfOutputsNumber of outputs available on sensor unit 2ro
INTEGER
.1.3.6.1.4.1.2606.4.2.4.6.1
cmcTcUnit2OutputTableHeadline of output table
SEQUENCE OF CmcTcUnit2OutputEntry
.1.3.6.1.4.1.2606.4.2.4.6.2
cmcTcUnit2OutputEntryEntries of output table
CmcTcUnit2OutputEntry
.1.3.6.1.4.1.2606.4.2.4.6.2.1
unit2OutputIndexIndex for the list of output entries. Its value ranges between 1 and the value of cmcTcUnit2NumberOfOutputs.ro
INTEGER
.1.3.6.1.4.1.2606.4.2.4.6.2.1.1
unit2OutputTypeType of output which is connected to sensor unit 2 to output[unit2OutputIndex] 1: no output connected 2: output failure 3: value overflow 4: output type 1, door locking TS8,Ergoform 5: output type 2, universal lock 1, lock with power 6: output type 3, universal lock 2, unlock with power 7: output type 4, fan relay 8: output type 5, fan controlled 9: output type 6, universal relay output 10: output type 7, room door lock 11: output type 8, power output 12: output type 9, door lock with Master key 13: output type 10, door lock FR(i) 14: setpoint (FCS, RTT) 15: setpoint temperature monitoring (RTT) 16: hysteresis of setpoint (RCT) 17: command for remote control of RCT 18: relay PSM, 1=On, 0=Off 19: high setpoint current monitoring PSM 20: low setpoint current monitoring PSM 21: setpoint temperature RTT 22: setpoint temperature monitoring RTT 23: power output 20A 24: door magnet (automatic door release) 30: control mode LCP 31: min fan speed (fan control) LCP 32: min delta T (fan control) LCP 33: max delta T (fan control) LCP 34: PID controller, KP, LCP 35: PID controller, KI, LCP 36 PID controller, KD, LCP 37 flowrate flowmeter, LCP 38: cw value of water (default: 4187) LCP 39: deltaT, LCP 40: control mode, LCP 42: setpoint high voltage PSM 43: setpoint low voltage PSM 44: setpoint high current PSM 45: setpoint low current PSM 46: command PSMro
Enumeration
.1.3.6.1.4.1.2606.4.2.4.6.2.1.2
unit2OutputTextDescriptional text for each output (entry in the table)rw
DisplayString
.1.3.6.1.4.1.2606.4.2.4.6.2.1.3
unit2OutputStatusActual status of the outputrw
Enumeration
.1.3.6.1.4.1.2606.4.2.4.6.2.1.4
unit2OutputValueSigned value for outputrw
INTEGER
.1.3.6.1.4.1.2606.4.2.4.6.2.1.5
unit2OutputSetCommand for outputrw
Enumeration
.1.3.6.1.4.1.2606.4.2.4.6.2.1.6
unit2OutputConfigConfiguration for output 1: disable remote control (e.g. keypad) 2: enable remote controlrw
Enumeration
.1.3.6.1.4.1.2606.4.2.4.6.2.1.7
unit2OutputDelayUnsigned Value for delay, after this time the output will fall into the previous staterw
INTEGER
.1.3.6.1.4.1.2606.4.2.4.6.2.1.8
unit2OutputTimeoutActionState for output if timeout (RS422) occursrw
Enumeration
.1.3.6.1.4.1.2606.4.2.4.6.2.1.9
cmcTcStatusUnit2Msg
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.2.4.7
cmcTcUnit2NumberOfMsgsNumber of alarms that can be created with sensor unit 2ro
INTEGER
.1.3.6.1.4.1.2606.4.2.4.7.1
cmcTcUnit2MsgTableHeadline of message table
SEQUENCE OF CmcTcUnit2MsgEntry
.1.3.6.1.4.1.2606.4.2.4.7.2
cmcTcUnit2MsgEntryEntries of message table
CmcTcUnit2MsgEntry
.1.3.6.1.4.1.2606.4.2.4.7.2.1
unit2MsgIndexIndex for the list of alarm entries. Its value ranges between 1 and the value of cmcTcUnit2NumberOfMsgs.ro
INTEGER
.1.3.6.1.4.1.2606.4.2.4.7.2.1.1
unit2MsgTextDescriptional text for each message (entry in the table)rw
DisplayString
.1.3.6.1.4.1.2606.4.2.4.7.2.1.2
unit2MsgStatusActual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to OFF 10: output is set to ON 11: door is open 12: door is closed 13: door is locked 14: door is unlocked by remote input, e.g. external cardreader 15: door is unlocked by reader or keypad connected to I2C 16: door is unlocked by SNMP set command (unit1OutputSet) 17: door is unlocked by WEB 18: door is unlocked by timer 19: no access, wrong keycode or cardnumber 20: orientation of PSM-Unit is circuit 1 21: orientation of PSM-Unit is circuit 2 22: battery low, wireless sensorro
Enumeration
.1.3.6.1.4.1.2606.4.2.4.7.2.1.3
unit2MsgRelaySetup of Alarm relay for this alarm 2: no switching of alarm relay 1: switching of alarm relayrw
Enumeration
.1.3.6.1.4.1.2606.4.2.4.7.2.1.4
unit2MsgBeeperSetup of Alarm beeper for this alarm 2: no audible alarm 1: audible alarmrw
Enumeration
.1.3.6.1.4.1.2606.4.2.4.7.2.1.5
unit2MsgTrap1Trap receiver 1 activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.4.7.2.1.6
unit2MsgTrap2Trap receiver 2 activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.4.7.2.1.7
unit2MsgTrap3Trap receiver 3 activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.4.7.2.1.8
unit2MsgTrap4Trap receiver 4 and Event Logging activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.4.7.2.1.9
unit2MsgQuitReset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' keyrw
Enumeration
.1.3.6.1.4.1.2606.4.2.4.7.2.1.10
unit2MsgDelayDelay of alarm conditionrw
INTEGER
.1.3.6.1.4.1.2606.4.2.4.7.2.1.11
cmcTcStatusSensorUnit3
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.2.5
cmcTcUnit3TypeOfDeviceType of sensor unit connected to port 3ro
Enumeration
.1.3.6.1.4.1.2606.4.2.5.1
cmcTcUnit3TextDescriptional text for sensor unit connected to port 3rw
DisplayString
.1.3.6.1.4.1.2606.4.2.5.2
cmcTcUnit3SerialSerialnumber of sensor unit connected to port 3ro
INTEGER
.1.3.6.1.4.1.2606.4.2.5.3
cmcTcUnit3StatusGeneral Status sensor unit connected to port 3 (1) OK (2) error, e. g. value overflow (3) configuration of sensor unit has changed, confirmation required (4) Quit from sensor unit to confirm configuration changes (5) timeout of sensor unit, confirmation required to unload this unit (6) sensor unit detected, needs to be confirmed (7) unit is not available (8) supply voltage is too low (9) Firmware upgrade runningro
Enumeration
.1.3.6.1.4.1.2606.4.2.5.4
cmcTcStatusUnit3Sensors
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.2.5.5
cmcTcUnit3NumberOfSensorsNumber of sensors connected to sensor unit 3ro
INTEGER
.1.3.6.1.4.1.2606.4.2.5.5.1
cmcTcUnit3SensorTableHeadline of sensor table
SEQUENCE OF CmcTcUnit3SensorEntry
.1.3.6.1.4.1.2606.4.2.5.5.2
cmcTcUnit3SensorEntryEntries of sensor table
CmcTcUnit3SensorEntry
.1.3.6.1.4.1.2606.4.2.5.5.2.1
unit3SensorIndexIndex for the list of value entries. Its value ranges between 1 and the value of cmcTcUnit3NumberOfSensors.ro
INTEGER
.1.3.6.1.4.1.2606.4.2.5.5.2.1.1
unit3SensorTypeType of sensor which is connected to sensor unit 3 to sensor[unit3SensorIndex] 1: no sensor connected 2: sensor failure 3: value overflow 4: sensor type 1, access sensor 5: sensor type 2, vibration sensor 6: sensor type 3, motion sensor 7: sensor type 4, smoke sensor 8: sensor type 5, air flow sensor 9: sensor type 6, reserved 10: sensor type 7, temperature sensor 11: sensor type 8, 4..20mA sensor 12: sensor type 9, humidity sensor 13: user sensor with normally opened contact 14: user sensor with normally closed contact 15: door locked sensor from locking device 16: remote unlock sensor (e.g. external keypad) 17: voltage sensor, indicates status of main voltage 18: voltage value 19: fan status 20: cardreader or keypad, connected to I2C port 21: duty cycle of fan, FCS-Unit 22: status of fan, FCS-Unit 23: leakage sensor 24: warning, RittalTopTherm(RTT)-Unit 25: alarm, RittalTopTherm-Unit 26: temperature difference filter monitor, RTT-Unit 27: heatflow RCT-Unit 28: alarm RCT-Unit 29: warning RCT-Unit 30: actual current*10, PSM-Unit 31: status PSM-Unit 32: position PSM-Unit, normal/reversed = circuit 1/2 33: air Flap 34: acoustic sensor 35: DET-AC fault (extinguisher) 36: DET-AC first alarm (extinguisher) 37: DET-AC main alarm (extinguisher) 38: DRC: RFID Tag 40-47: RPM Fan 1.1 - Fan 4.2, LCP 48-55: Air temperature 1.1 - 4.2, LCP 56,57: actual temperature 1,2, LCP 58: water inlet temperature, LCP 59: water outlet temperature, LCP 60: water flow 61: fan speed (desired value) 62: status valve, LCP 63: status LCP 64: temperature difference water temperatures 65: control temperature 1, LCP 66: control temperature 2, LCP 67: condensate pump, duration, LCP 68: condensate pump, cycles, LCP 72: total energy*10 (kWh), PSM 73: total power*10 (kW), PSM 74: frequency*10 (Hz), PSM 75: voltage*10 (V), PSM 76: voltage status, PSM 77: current*10 (A), PSM 78: current status, PSM 79: power*10 (kW) per phase, PSM 80: energy*10 (kWh) per phase, PSM 81: temporary energy*10 (kWh) per phase, PSM 100: temperature sensor, wireless 101: temperature sensor (combi), wireless 102: humidity sensor, wireless 103: access sensor, wireless 104: user sensor with normally opened contact, wireless 105: user sensor with normally closed contact, wireless 106: analog sensor 4..20mA, wirelessro
Enumeration
.1.3.6.1.4.1.2606.4.2.5.5.2.1.2
unit3SensorTextDescriptional text for each sensor (entry in the table)rw
DisplayString
.1.3.6.1.4.1.2606.4.2.5.5.2.1.3
unit3SensorStatusActual status of the sensorro
Enumeration
.1.3.6.1.4.1.2606.4.2.5.5.2.1.4
unit3SensorValueValue of sensorro
INTEGER
.1.3.6.1.4.1.2606.4.2.5.5.2.1.5
unit3SensorSetHighValue for high setpoint of sensorrw
INTEGER
.1.3.6.1.4.1.2606.4.2.5.5.2.1.6
unit3SensorSetLowValue for low setpoint of sensorrw
INTEGER
.1.3.6.1.4.1.2606.4.2.5.5.2.1.7
unit3SensorSetWarnValue for warning setpoint of sensor, also used as fan thresholdrw
INTEGER
.1.3.6.1.4.1.2606.4.2.5.5.2.1.8
unit3SensorHysteresis% -Value for hysteresis for High, Low and Warning, input in % from actual setpointrw
INTEGER
.1.3.6.1.4.1.2606.4.2.5.5.2.1.9
unit3SensorDisplayFactorFactor of sensor value and setpoints, devide actual value with this value, e. g. factor = 10: sensor value = 100, actual value = 10.0ro
INTEGER
.1.3.6.1.4.1.2606.4.2.5.5.2.1.10
unit3SensorScaleStartValue for start value for scaling of 0..100% (4..20mA) sensor, example: acutal range of value of 4..20mA sensor is from 10 to 60A, then this variable is set to 10, also valid for setpointsrw
INTEGER
.1.3.6.1.4.1.2606.4.2.5.5.2.1.11
unit3SensorScaleEndValue for end value for scaling of 0..100% (4..20mA) sensor, example: acutal range of value of 4..20mA sensor is from 10 to 60A, then this variable is set to 60, also valid for setpointsrw
INTEGER
.1.3.6.1.4.1.2606.4.2.5.5.2.1.12
unit3SensorUnitUnit for 0..100% (4..20mA) sensor, example: acutal range of value of 4..20mA sensor is from 10 to 60A, then this variable is set to 'A'rw
DisplayString
.1.3.6.1.4.1.2606.4.2.5.5.2.1.13
unit3SensorInfoAdditional information to the sensor, e. g. Serialnumber, Signal Quality..ro
DisplayString
.1.3.6.1.4.1.2606.4.2.5.5.2.1.14
cmcTcStatusUnit3Outputs
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.2.5.6
cmcTcUnit3NumberOfOutputsNumber of outputs available on sensor unit 3ro
INTEGER
.1.3.6.1.4.1.2606.4.2.5.6.1
cmcTcUnit3OutputTableHeadline of output table
SEQUENCE OF CmcTcUnit3OutputEntry
.1.3.6.1.4.1.2606.4.2.5.6.2
cmcTcUnit3OutputEntryEntries of output table
CmcTcUnit3OutputEntry
.1.3.6.1.4.1.2606.4.2.5.6.2.1
unit3OutputIndexIndex for the list of output entries. Its value ranges between 1 and the value of cmcTcUnit3NumberOfOutputs.ro
INTEGER
.1.3.6.1.4.1.2606.4.2.5.6.2.1.1
unit3OutputTypeType of output which is connected to sensor unit 3 to output[unit3OutputIndex] 1: no output connected 2: output failure 3: value overflow 4: output type 1, door locking TS8,Ergoform 5: output type 2, universal lock 1, lock with power 6: output type 3, universal lock 2, unlock with power 7: output type 4, fan relay 8: output type 5, fan controlled 9: output type 6, universal relay output 10: output type 7, room door lock 11: output type 8, power output 12: output type 9, door lock with Master key 13: output type 10, door lock FR(i) 14: setpoint (FCS, RTT) 15: setpoint temperature monitoring (RTT) 16: hysteresis of setpoint (RCT) 17: command for remote control of RCT 18: relay PSM, 1=On, 0=Off 19: high setpoint current monitoring PSM 20: low setpoint current monitoring PSM 21: setpoint temperature RTT 22: setpoint temperature monitoring RTT 23: power output 20A 24: door magnet (automatic door release) 30: control mode LCP 31: min fan speed (fan control) LCP 32: min delta T (fan control) LCP 33: max delta T (fan control) LCP 34: PID controller, KP, LCP 35: PID controller, KI, LCP 36 PID controller, KD, LCP 37 flowrate flowmeter, LCP 38: cw value of water (default: 4187) LCP 39: deltaT, LCP 40: control mode, LCP 42: setpoint high voltage PSM 43: setpoint low voltage PSM 44: setpoint high current PSM 45: setpoint low current PSM 46: command PSMro
Enumeration
.1.3.6.1.4.1.2606.4.2.5.6.2.1.2
unit3OutputTextDescriptional text for each output (entry in the table)rw
DisplayString
.1.3.6.1.4.1.2606.4.2.5.6.2.1.3
unit3OutputStatusActual status of the outputrw
Enumeration
.1.3.6.1.4.1.2606.4.2.5.6.2.1.4
unit3OutputValueValue for outputrw
INTEGER
.1.3.6.1.4.1.2606.4.2.5.6.2.1.5
unit3OutputSetCommand for outputrw
Enumeration
.1.3.6.1.4.1.2606.4.2.5.6.2.1.6
unit3OutputConfigConfiguration for output 1: disable remote control (e.g. keypad) 2: enable remote controlrw
Enumeration
.1.3.6.1.4.1.2606.4.2.5.6.2.1.7
unit3OutputDelayUnsigned Value for delay, after this time the output will fall into the previous staterw
INTEGER
.1.3.6.1.4.1.2606.4.2.5.6.2.1.8
unit3OutputTimeoutActionState for output if timeout (RS422) occursrw
Enumeration
.1.3.6.1.4.1.2606.4.2.5.6.2.1.9
cmcTcStatusUnit3Msg
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.2.5.7
cmcTcUnit3NumberOfMsgsNumber of alarms that can be created with sensor unit 3ro
INTEGER
.1.3.6.1.4.1.2606.4.2.5.7.1
cmcTcUnit3MsgTableHeadline of message table
SEQUENCE OF CmcTcUnit3MsgEntry
.1.3.6.1.4.1.2606.4.2.5.7.2
cmcTcUnit3MsgEntryEntries of message table
CmcTcUnit3MsgEntry
.1.3.6.1.4.1.2606.4.2.5.7.2.1
unit3MsgIndexIndex for the list of alarm entries. Its value ranges between 1 and the value of cmcTcUnit3NumberOfMsgs.ro
INTEGER
.1.3.6.1.4.1.2606.4.2.5.7.2.1.1
unit3MsgTextDescriptional text for each message (entry in the table)rw
DisplayString
.1.3.6.1.4.1.2606.4.2.5.7.2.1.2
unit3MsgStatusActual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to OFF 10: output is set to ON 11: door is open 12: door is closed 13: door is locked 14: door is unlocked by remote input, e.g. external cardreader 15: door is unlocked by reader or keypad connected to I2C 16: door is unlocked by SNMP set command (unit1OutputSet) 17: door is unlocked by WEB 18: door is unlocked by timer 19: no access, wrong keycode or cardnumber 20: orientation of PSM-Unit is circuit 1 21: orientation of PSM-Unit is circuit 2 22: battery low, wireless sensorro
Enumeration
.1.3.6.1.4.1.2606.4.2.5.7.2.1.3
unit3MsgRelaySetup of Alarm relay for this alarm 1: no switching of alarm relay 2: switching of alarm relayrw
Enumeration
.1.3.6.1.4.1.2606.4.2.5.7.2.1.4
unit3MsgBeeperSetup of Alarm beeper for this alarm 1: no audible alarm 2: audible alarmrw
Enumeration
.1.3.6.1.4.1.2606.4.2.5.7.2.1.5
unit3MsgTrap1Trap receiver 1 activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.5.7.2.1.6
unit3MsgTrap2Trap receiver 2 activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.5.7.2.1.7
unit3MsgTrap3Trap receiver 3 activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.5.7.2.1.8
unit3MsgTrap4Trap receiver 4 and Event Logging activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.5.7.2.1.9
unit3MsgQuitReset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' keyrw
Enumeration
.1.3.6.1.4.1.2606.4.2.5.7.2.1.10
unit3MsgDelayDelay of alarm conditionrw
INTEGER
.1.3.6.1.4.1.2606.4.2.5.7.2.1.11
cmcTcStatusSensorUnit4
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.2.6
cmcTcUnit4TypeOfDeviceType of sensor unit connected to port 4ro
Enumeration
.1.3.6.1.4.1.2606.4.2.6.1
cmcTcUnit4TextDescriptional text for sensor unit connected to port 4rw
DisplayString
.1.3.6.1.4.1.2606.4.2.6.2
cmcTcUnit4SerialSerialnumber of sensor unit connected to port 4ro
INTEGER
.1.3.6.1.4.1.2606.4.2.6.3
cmcTcUnit4StatusGeneral Status sensor unit connected to port 4 (1) OK (2) error, e. g. value overflow (3) configuration of sensor unit has changed, confirmation required (4) Quit from sensor unit to confirm configuration changes (5) timeout of sensor unit, confirmation required to unload this unit (6) sensor unit detected, needs to be confirmed (7) unit is not available (8) supply voltage is too low (9) Firmware upgrade runningro
Enumeration
.1.3.6.1.4.1.2606.4.2.6.4
cmcTcStatusUnit4Sensors
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.2.6.5
cmcTcUnit4NumberOfSensorsNumber of sensors connected to sensor unit 4ro
INTEGER
.1.3.6.1.4.1.2606.4.2.6.5.1
cmcTcUnit4SensorTableHeadline of sensor table
SEQUENCE OF CmcTcUnit4SensorEntry
.1.3.6.1.4.1.2606.4.2.6.5.2
cmcTcUnit4SensorEntryEntries of sensor table
CmcTcUnit4SensorEntry
.1.3.6.1.4.1.2606.4.2.6.5.2.1
unit4SensorIndexIndex for the list of value entries. Its value ranges between 1 and the value of cmcTcUnit4NumberOfSensors.ro
INTEGER
.1.3.6.1.4.1.2606.4.2.6.5.2.1.1
unit4SensorTypeType of sensor which is connected to sensor unit 4 to sensor[unit4SensorIndex] 1: no sensor connected 2: sensor failure 3: value overflow 4: sensor type 1, access sensor 5: sensor type 2, vibration sensor 6: sensor type 3, motion sensor 7: sensor type 4, smoke sensor 8: sensor type 5, air flow sensor 9: sensor type 6, reserved 10: sensor type 7, temperature sensor 11: sensor type 8, 4..20mA sensor 12: sensor type 9, humidity sensor 13: user sensor with normally opened contact 14: user sensor with normally closed contact 15: door locked sensor from locking device 16: remote unlock sensor (e.g. external keypad) 17: voltage sensor, indicates status of main voltage 18: voltage value 19: fan status 20: cardreader or keypad, connected to I2C port 21: duty cycle of fan, FCS-Unit 22: status of fan, FCS-Unit 23: leakage sensor 24: warning, RittalTopTherm(RTT)-Unit 25: alarm, RittalTopTherm-Unit 26: temperature difference filter monitor, RTT-Unit 27: heatflow RCT-Unit 28: alarm RCT-Unit 29: warning RCT-Unit 30: actual current*10, PSM-Unit 31: status PSM-Unit 32: position PSM-Unit, normal/reversed = circuit 1/2 33: air Flap 34: acoustic sensor 35: DET-AC fault (extinguisher) 36: DET-AC first alarm (extinguisher) 37: DET-AC main alarm (extinguisher) 38: DRC: RFID Tag 40-47: RPM Fan 1.1 - Fan 4.2, LCP 48-55: Air temperature 1.1 - 4.2, LCP 56,57: actual temperature 1,2, LCP 58: water inlet temperature, LCP 59: water outlet temperature, LCP 60: water flow 61: fan speed (desired value) 62: status valve, LCP 63: status LCP 64: temperature difference water temperatures 65: control temperature 1, LCP 66: control temperature 2, LCP 67: condensate pump, duration, LCP 68: condensate pump, cycles, LCP 72: total energy*10 (kWh), PSM 73: total power*10 (kW), PSM 74: frequency*10 (Hz), PSM 75: voltage*10 (V), PSM 76: voltage status, PSM 77: current*10 (A), PSM 78: current status, PSM 79: power*10 (kW) per phase, PSM 80: energy*10 (kWh) per phase, PSM 81: temporary energy*10 (kWh) per phase, PSM 100: temperature sensor, wireless 101: temperature sensor (combi), wireless 102: humidity sensor, wireless 103: access sensor, wireless 104: user sensor with normally opened contact, wireless 105: user sensor with normally closed contact, wireless 106: analog sensor 4..20mA, wirelessro
Enumeration
.1.3.6.1.4.1.2606.4.2.6.5.2.1.2
unit4SensorTextDescriptional text for each sensor (entry in the table)rw
DisplayString
.1.3.6.1.4.1.2606.4.2.6.5.2.1.3
unit4SensorStatusActual status of the sensorro
Enumeration
.1.3.6.1.4.1.2606.4.2.6.5.2.1.4
unit4SensorValueValue of sensorro
INTEGER
.1.3.6.1.4.1.2606.4.2.6.5.2.1.5
unit4SensorSetHighValue for high setpoint of sensorrw
INTEGER
.1.3.6.1.4.1.2606.4.2.6.5.2.1.6
unit4SensorSetLowValue for low setpoint of sensorrw
INTEGER
.1.3.6.1.4.1.2606.4.2.6.5.2.1.7
unit4SensorSetWarnValue for warning setpoint of sensor, also used as fan thresholdrw
INTEGER
.1.3.6.1.4.1.2606.4.2.6.5.2.1.8
unit4SensorHysteresis% -Value for hysteresis for High, Low and Warning, input in % from actual setpointrw
INTEGER
.1.3.6.1.4.1.2606.4.2.6.5.2.1.9
unit4SensorDisplayFactorFactor of sensor value and setpoints, devide actual value with this value, e. g. factor = 10: sensor value = 100, actual value = 10.0ro
INTEGER
.1.3.6.1.4.1.2606.4.2.6.5.2.1.10
unit4SensorScaleStartValue for start value for scaling of 0..100% (4..20mA) sensor, example: acutal range of value of 4..20mA sensor is from 10 to 60A, then this variable is set to 10, also valid for setpointsrw
INTEGER
.1.3.6.1.4.1.2606.4.2.6.5.2.1.11
unit4SensorScaleEndValue for end value for scaling of 0..100% (4..20mA) sensor, example: acutal range of value of 4..20mA sensor is from 10 to 60A, then this variable is set to 60, also valid for setpointsrw
INTEGER
.1.3.6.1.4.1.2606.4.2.6.5.2.1.12
unit4SensorUnitUnit for 0..100% (4..20mA) sensor, example: acutal range of value of 4..20mA sensor is from 10 to 60A, then this variable is set to 'A'rw
DisplayString
.1.3.6.1.4.1.2606.4.2.6.5.2.1.13
unit4SensorInfoAdditional information to the sensor, e. g. Serialnumber, Signal Quality..ro
DisplayString
.1.3.6.1.4.1.2606.4.2.6.5.2.1.14
cmcTcStatusUnit4Outputs
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.2.6.6
cmcTcUnit4NumberOfOutputsNumber of outputs available on sensor unit 4ro
INTEGER
.1.3.6.1.4.1.2606.4.2.6.6.1
cmcTcUnit4OutputTableHeadline of output table
SEQUENCE OF CmcTcUnit4OutputEntry
.1.3.6.1.4.1.2606.4.2.6.6.2
cmcTcUnit4OutputEntryEntries of output table
CmcTcUnit4OutputEntry
.1.3.6.1.4.1.2606.4.2.6.6.2.1
unit4OutputIndexIndex for the list of output entries. Its value ranges between 1 and the value of cmcTcUnit4NumberOfOutputs.ro
INTEGER
.1.3.6.1.4.1.2606.4.2.6.6.2.1.1
unit4OutputTypeType of output which is connected to sensor unit 4 to output[unit4OutputIndex] 1: no output connected 2: output failure 3: value overflow 4: output type 1, door locking TS8,Ergoform 5: output type 2, universal lock 1, lock with power 6: output type 3, universal lock 2, unlock with power 7: output type 4, fan relay 8: output type 5, fan controlled 9: output type 6, universal relay output 10: output type 7, room door lock 11: output type 8, power output 12: output type 9, door lock with Master key 13: output type 10, door lock FR(i) 14: setpoint (FCS, RTT) 15: setpoint temperature monitoring (RTT) 16: hysteresis of setpoint (RCT) 17: command for remote control of RCT 18: relay PSM, 1=On, 0=Off 19: high setpoint current monitoring PSM 20: low setpoint current monitoring PSM 21: setpoint temperature RTT 22: setpoint temperature monitoring RTT 23: power output 20A 24: door magnet (automatic door release) 30: control mode LCP 31: min fan speed (fan control) LCP 32: min delta T (fan control) LCP 33: max delta T (fan control) LCP 34: PID controller, KP, LCP 35: PID controller, KI, LCP 36 PID controller, KD, LCP 37 flowrate flowmeter, LCP 38: cw value of water (default: 4187) LCP 39: deltaT, LCP 40: control mode, LCP 42: setpoint high voltage PSM 43: setpoint low voltage PSM 44: setpoint high current PSM 45: setpoint low current PSM 46: command PSMro
Enumeration
.1.3.6.1.4.1.2606.4.2.6.6.2.1.2
unit4OutputTextDescriptional text for each output (entry in the table)rw
DisplayString
.1.3.6.1.4.1.2606.4.2.6.6.2.1.3
unit4OutputStatusActual status of the outputrw
Enumeration
.1.3.6.1.4.1.2606.4.2.6.6.2.1.4
unit4OutputValueValue for outputrw
INTEGER
.1.3.6.1.4.1.2606.4.2.6.6.2.1.5
unit4OutputSetCommand for outputrw
Enumeration
.1.3.6.1.4.1.2606.4.2.6.6.2.1.6
unit4OutputConfigConfiguration for output 1: disable remote control (e.g. keypad) 2: enable remote controlrw
Enumeration
.1.3.6.1.4.1.2606.4.2.6.6.2.1.7
unit4OutputDelayUnsigned Value for delay, after this time the output will fall into the previous staterw
INTEGER
.1.3.6.1.4.1.2606.4.2.6.6.2.1.8
unit4OutputTimeoutActionState for output if timeout (RS422) occursrw
Enumeration
.1.3.6.1.4.1.2606.4.2.6.6.2.1.9
cmcTcStatusUnit4Msg
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.2.6.7
cmcTcUnit4NumberOfMsgsNumber of alarms that can be created with sensor unit 4ro
INTEGER
.1.3.6.1.4.1.2606.4.2.6.7.1
cmcTcUnit4MsgTableHeadline of message table
SEQUENCE OF CmcTcUnit4MsgEntry
.1.3.6.1.4.1.2606.4.2.6.7.2
cmcTcUnit4MsgEntryEntries of message table
CmcTcUnit4MsgEntry
.1.3.6.1.4.1.2606.4.2.6.7.2.1
unit4MsgIndexIndex for the list of alarm entries. Its value ranges between 1 and the value of cmcTcUnit4NumberOfMsgs.ro
INTEGER
.1.3.6.1.4.1.2606.4.2.6.7.2.1.1
unit4MsgTextDescriptional text for each message (entry in the table)rw
DisplayString
.1.3.6.1.4.1.2606.4.2.6.7.2.1.2
unit4MsgStatusActual message status 1: not available 2: configuration has changed (sensor new, changed, lost) 3: error 4: OK 5: alarm, e.g. smoke, vibration... 6: warning of analog value, value reached warning threshold 7: analog value too low, value reached low threshold 8: analog value too high, value reached high threshold 9: output is set to OFF 10: output is set to ON 11: door is open 12: door is closed 13: door is locked 14: door is unlocked by remote input, e.g. external cardreader 15: door is unlocked by reader or keypad connected to I2C 16: door is unlocked by SNMP set command (unit1OutputSet) 17: door is unlocked by WEB 18: door is unlocked by timer 19: no access, wrong keycode or cardnumber 20: orientation of PSM-Unit is circuit 1 21: orientation of PSM-Unit is circuit 2 22: battery low, wireless sensorro
Enumeration
.1.3.6.1.4.1.2606.4.2.6.7.2.1.3
unit4MsgRelaySetup of Alarm relay for this alarm 1: no switching of alarm relay 2: switching of alarm relayrw
Enumeration
.1.3.6.1.4.1.2606.4.2.6.7.2.1.4
unit4MsgBeeperSetup of Alarm beeper for this alarm 1: no audible alarm 2: audible alarmrw
Enumeration
.1.3.6.1.4.1.2606.4.2.6.7.2.1.5
unit4MsgTrap1Trap receiver 1 activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.6.7.2.1.6
unit4MsgTrap2Trap receiver 2 activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.6.7.2.1.7
unit4MsgTrap3Trap receiver 3 activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.6.7.2.1.8
unit4MsgTrap4Trap receiver 4 and Event Logging activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.6.7.2.1.9
unit4MsgQuitReset of this alarm 1: auto 2: manual, alarm needs confirmation, e. g. with 'C' keyrw
Enumeration
.1.3.6.1.4.1.2606.4.2.6.7.2.1.10
unit4MsgDelayDelay of alarm conditionrw
INTEGER
.1.3.6.1.4.1.2606.4.2.6.7.2.1.11
cmcTcStatusExtUnit
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.2.7
cmcTcValuesRelaySetup of Alarm relay for alarm ext. unit(s) 1: no switching of alarm relay 2: switching of alarm relayrw
Enumeration
.1.3.6.1.4.1.2606.4.2.7.1
cmcTcValuesBeeperSetup of Alarm beeper for alarm ext. unit(s) 1: no audible alarm 2: audible alarmrw
Enumeration
.1.3.6.1.4.1.2606.4.2.7.2
cmcTcValuesTrap1Trap receiver 1 activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.7.3
cmcTcValuesTrap2Trap receiver 2 activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.7.4
cmcTcValuesTrap3Trap receiver 3 activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.7.5
cmcTcValuesTrap4Trap receiver 4 and Event Logging activatedrw
Enumeration
.1.3.6.1.4.1.2606.4.2.7.6
cmcTcNumberOfValuesNumber of values availabel on extension units connected to the CMCro
INTEGER
.1.3.6.1.4.1.2606.4.2.7.7
cmcTcValuesTableHeadline of values-table
SEQUENCE OF CmcTcValuesEntry
.1.3.6.1.4.1.2606.4.2.7.8
cmcTcValuesEntryEntries of values-table
CmcTcValuesEntry
.1.3.6.1.4.1.2606.4.2.7.8.1
valuesIndexIndex for the list of value entries. Its value ranges between 1 and the value of cmcTcNumberOfValues.ro
INTEGER
.1.3.6.1.4.1.2606.4.2.7.8.1.1
valuesTextDescriptional text for each value (entry in the table) of the extension cardrw
DisplayString
.1.3.6.1.4.1.2606.4.2.7.8.1.2
valuesStatusActual status of the value of the extension cardro
Enumeration
.1.3.6.1.4.1.2606.4.2.7.8.1.3
valuesValueValue of sensorro
INTEGER
.1.3.6.1.4.1.2606.4.2.7.8.1.4
valuesSetHighValue for high setpoint of sensorrw
INTEGER
.1.3.6.1.4.1.2606.4.2.7.8.1.5
valuesSetLowValue for low setpoint of sensorrw
INTEGER
.1.3.6.1.4.1.2606.4.2.7.8.1.6
valuesHysteresis% -Value for hysteresis for High and Low setpoints, input in % from actual setpointrw
INTEGER
.1.3.6.1.4.1.2606.4.2.7.8.1.7
cmcTcSetup
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.3
cmcTcSetupGeneral
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.3.1
cmcTcSetTempUnitUnit of all temperature values and setpoints, Celsius or Fahrenheitrw
Enumeration
.1.3.6.1.4.1.2606.4.3.1.1
cmcTcSetBeeperAudible alarm in CMC-TC unit: (2): beeper is on (1): beeper is off (general)rw
Enumeration
.1.3.6.1.4.1.2606.4.3.1.2
cmcTcQuitRelayEnable or disable acknowledging currently active alarm relay (with 'C' on CMC-TC).rw
Enumeration
.1.3.6.1.4.1.2606.4.3.1.3
cmcTcLogicRelayLogic of alarm relay: (1) Relay will pick up in case of an alarm (2) Relay will release in case of an alarm (3) Relay off (general)rw
Enumeration
.1.3.6.1.4.1.2606.4.3.1.4
cmcTcWebAccessWeb access via HTTP: (1) view only (2) full Access, read and set (3) Web disabled (general)rw
Enumeration
.1.3.6.1.4.1.2606.4.3.1.5
cmcTcSetupDateactual Date in format DD.MM.YYYYrw
DisplayString
.1.3.6.1.4.1.2606.4.3.1.6
cmcTcSetupTimeactual Time in format HH:MM:SS, HH (0-23), MM (0-59), SS (0-59)rw
DisplayString
.1.3.6.1.4.1.2606.4.3.1.7
cmcTcTimerTable1
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.3.1.8
cmcTcTimerNumberNumber of value-table entries=number of outlets available on this unitro
INTEGER
.1.3.6.1.4.1.2606.4.3.1.8.1
cmcTcTimerTableHeadline of status-table
SEQUENCE OF CmcTcTimerEntry
.1.3.6.1.4.1.2606.4.3.1.8.2
cmcTcTimerEntryEntries of timer-table
CmcTcTimerEntry
.1.3.6.1.4.1.2606.4.3.1.8.2.1
cmcTcTimerIndexIndex for the list of timer entries. Its value ranges between 1 and the value of cmcTcTimerNumber.ro
INTEGER
.1.3.6.1.4.1.2606.4.3.1.8.2.1.1
cmcTcTimerStatusActual status of the timerro
Enumeration
.1.3.6.1.4.1.2606.4.3.1.8.2.1.2
cmcTcTimerDayOfWeekSelection of day of week for timer to switchrw
Enumeration
.1.3.6.1.4.1.2606.4.3.1.8.2.1.3
cmcTcTimeOnTime to switch on current function, Format: HH:MMrw
DisplayString
.1.3.6.1.4.1.2606.4.3.1.8.2.1.4
cmcTcTimeOffTime to switch off current function, Format: HH:MMrw
DisplayString
.1.3.6.1.4.1.2606.4.3.1.8.2.1.5
cmcTcTimeControlControl via RTCrw
Enumeration
.1.3.6.1.4.1.2606.4.3.1.8.2.1.6
cmcTcTimerFunctionFunction which is controlled via timer 1: unlock via keypad 1 on unit 1 or remote input lock 1 is disabled 2: unlock via keypad 2 on unit 1 or remote input lock 2 is disabled 3 unlock via keypad 1 on unit 2 or remote input lock 1 is disabled 4: unlock via keypad 2 on unit 2 or remote input lock 2 is disabled 5: unlock via keypad 1 on unit 3 or remote input lock 1 is disabled 6: unlock via keypad 2 on unit 3 or remote input lock 2 is disabled 7: unlock via keypad 1 on unit 4 or remote input lock 1 is disabled 8: unlock via keypad 2 on unit 4 or remote input lock 2 is disabled 9: Lock of door 1 on unit 1 will be unlocked 10: Lock of door 2 on unit 1 will be unlocked 11: Lock of door 1 on unit 2 will be unlocked 12: Lock of door 2 on unit 2 will be unlocked 13: Lock of door 1 on unit 3 will be unlocked 14: Lock of door 2 on unit 3 will be unlocked 15: Lock of door 1 on unit 4 will be unlocked 16: Lock of door 2 on unit 4 will be unlocked 17-20: sending Traps to this Trap receiver will be disabled 21: sending SMS will be disabled generally 22-25: Scheduled alarm off 26-29: sending SMS to phone number 1..4 will be disabledrw
Enumeration
.1.3.6.1.4.1.2606.4.3.1.8.2.1.7
cmcTcTrapControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.4
cmcTcTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.4.7
cmcTcTraptableNumberNumber of trapTable entries. The number of trap-receiverro
INTEGER
.1.3.6.1.4.1.2606.4.4.7.1
cmcTcTrapTableTableA list of trap-receiver entries
SEQUENCE OF CmcTcTrapTableEntry
.1.3.6.1.4.1.2606.4.4.7.2
cmcTcTrapTableEntryEntries of trapTable
CmcTcTrapTableEntry
.1.3.6.1.4.1.2606.4.4.7.2.1
trapIndexIndex for the trap-receiver-table. Its value ranges between 1 and the value of traptableNumberro
INTEGER
.1.3.6.1.4.1.2606.4.4.7.2.1.1
trapStatusEnable or disable trap receiverrw
Enumeration
.1.3.6.1.4.1.2606.4.4.7.2.1.2
trapIPaddressIP-address of trap-receiverrw
DisplayString
.1.3.6.1.4.1.2606.4.4.7.2.1.3
cmcTcControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.2606.4.5
cmcTcQuitUnitCommand to quit (acknowledge) alarms of CMC-TC unit. Setting to 'quit' (2) will have same result as pressing 'C' on Units. Variable is automatically set back to 'noQuit' (1).rw
Enumeration
.1.3.6.1.4.1.2606.4.5.1