PT-SFP-MIB
The PT-SFP-MIB module enables monitoring of optical transceiver parameters compliant with the SFF-8472 standard, specifically retrieving real-time telemetry such as temperature, supply voltage, laser bias current, and optical power levels from PT-branded Small Form-factor Pluggable modules.
Imported Objects
Objects
30 total| Object Name |
|---|
ptSFPThis is the MIB of PT SFP specifics. Most entries are read from the SFP itself according to SFF-8472 MODULE-IDENTITY .1.3.6.1.4.1.18086.6 |
ptSFPTableAn table of SFP Table entries. SEQUENCE OF PtSFPEntry .1.3.6.1.4.1.18086.6.1 |
ptSFPEntryAn entry of PT SFP application. PtSFPEntry .1.3.6.1.4.1.18086.6.1.1 |
installedSFPType of the inserted module, see textual conventionro PortInterfaceTC .1.3.6.1.4.1.18086.6.1.1.1 |
installStateStatus of the inserted module, see textual conventionro InstallStateTC .1.3.6.1.4.1.18086.6.1.1.2 |
vendorNameSFP vendor name as reported by the SFPro OCTET STRING .1.3.6.1.4.1.18086.6.1.1.3 |
vendorOuiSFP vendor IEEE company ID as reported by the SFPro Integer32 .1.3.6.1.4.1.18086.6.1.1.4 |
vendorPnPart number provided by SFP vendor (ASCII) as reported by the SFPro OCTET STRING .1.3.6.1.4.1.18086.6.1.1.5 |
vendorRevRevision level for part number provided by vendor (ASCII) as reported by the SFPro OCTET STRING .1.3.6.1.4.1.18086.6.1.1.6 |
vendorSnSerial number provided by vendor (ASCII) as reported by the SFPro OCTET STRING .1.3.6.1.4.1.18086.6.1.1.7 |
saleableEntityCodePropriety product name as reported by the SFP's Vendor Specific EEPROMro OCTET STRING .1.3.6.1.4.1.18086.6.1.1.8 |
connectorTypeAn integer which indicates the type of CONNECTOR_TYPE according SFF-8024. See also textual conventionro ConnectorTypeTC .1.3.6.1.4.1.18086.6.1.1.9 |
installedWavelengthAn integer that in case of an optical SFP, is the laser wavelength in nm. See also textual convention.ro WaveLengthTC .1.3.6.1.4.1.18086.6.1.1.10 |
levelRxThe input level in dBm (optical interfaces only). The value is an offset. The value 100 represents 0 dBm. The value 50 represents no signal.ro Integer32 .1.3.6.1.4.1.18086.6.1.1.11 |
rxPowerThe received light power, in dBm.ro OCTET STRING .1.3.6.1.4.1.18086.6.1.1.12 |
txPowerThe transmit light power, in dBm.ro OCTET STRING .1.3.6.1.4.1.18086.6.1.1.13 |
brNominalThe nominal bit rate, in units of 100 Mbps.ro Integer32 .1.3.6.1.4.1.18086.6.1.1.14 |
length9m1kmLink length supported for 9/125 um single fiber, units of 1 kmro Integer32 .1.3.6.1.4.1.18086.6.1.1.15 |
length9m100mLink length supported for 9/125 um single fiber, units of 100 mro Integer32 .1.3.6.1.4.1.18086.6.1.1.16 |
length50m10mLink length supported for 50/125 um OM2 fiber, units of 10 mro Integer32 .1.3.6.1.4.1.18086.6.1.1.17 |
length62m10mLink length supported for 62.5/125 um OM1 fiber, units of 10 mro Integer32 .1.3.6.1.4.1.18086.6.1.1.18 |
lengthCopper1mLink length supported for copper or direct attach cable, units of mro Integer32 .1.3.6.1.4.1.18086.6.1.1.19 |
temperatureThe SFP module temperature, in degree Celsiusro OCTET STRING .1.3.6.1.4.1.18086.6.1.1.20 |
vccThe supply voltage of the interface module, in V.ro OCTET STRING .1.3.6.1.4.1.18086.6.1.1.21 |
biasCurrentThe bias current of the interface module, in mA.ro OCTET STRING .1.3.6.1.4.1.18086.6.1.1.22 |
ptSFPConformance OBJECT IDENTIFIER .1.3.6.1.4.1.18086.6.2 |
ptSFPCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.18086.6.2.1 |
ptSFPFullComplianceThe compliance statement for SNMP entities which implement everything. Unknown .1.3.6.1.4.1.18086.6.2.1.1 |
ptSFPGroups OBJECT IDENTIFIER .1.3.6.1.4.1.18086.6.2.2 |
ptSFPCompleteGroupA collection of all current objects in this MIB module. Unknown .1.3.6.1.4.1.18086.6.2.2.1 |
More MIBs from Protelevision
Browse all ProtelevisionMIBs →The PT3080-MIB module enables SNMP-based monitoring and management of Protelevision Technologies PT3080 DVB-T/H modulators, specifically tracking digital broadcast transmission parameters such as signal power, modulation error ratio (MER), bit error rate (BER), and carrier status. This MIB facilitates the collection of performance counters and alarm states required to maintain the integrity of terrestrial digital television signal distribution.
The PT-RADIOLINK-MIB module enables the monitoring and management of PT (PT Telecom) proprietary radio link hardware, specifically exposing performance metrics such as link status, signal strength, error counters, and interface utilization for point-to-point microwave or wireless backhaul systems.
The PT-FM-MIB module provides vendor-specific monitoring for PT (Palo Alto Networks) firewall hardware and software, enabling the collection of detailed fault management metrics such as interface status, hardware component health, and system event logs. This MIB facilitates granular visibility into device operational states and failure conditions to support automated alerting and diagnostic troubleshooting within Palo Alto Networks environments.
The PT-TRAP-MIB module defines enterprise-specific SNMP trap definitions for PT products to notify management systems of critical hardware faults, link state transitions, and operational anomalies. These traps enable automated alerting and event correlation for PT infrastructure without requiring active polling of specific performance metrics.
The PT-PM-MIB module provides SNMP management capabilities for PT (Palo Alto Networks) specific Performance Monitoring metrics, enabling the collection of device health statistics, resource utilization counters, and operational status data for Palo Alto firewalls.
The PT-MONITOR-MIB provides vendor-specific SNMP objects for monitoring performance metrics and operational status of PT (Pulse Technology) hardware devices, including interface statistics, system health indicators, and resource utilization data.