PDU-MIB
AI MIB Summary
The PDU-MIB enables SNMP-based monitoring and management of Raritan Dominion PX Power Distribution Units, providing access to power metrics such as voltage, current, power consumption, and outlet-level status for individual PDU ports.
This mib describes the SNMP functions of the Dominion PX Power Distribution Unit by Raritan Computer.
Main OID:
raritan.1.3.6.1.4.1.13742
364
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
364 total| Object Name |
|---|
raritanThis mib describes the SNMP functions of the Dominion PX Power Distribution Unit by Raritan Computer. MODULE-IDENTITY .1.3.6.1.4.1.13742 |
pdu OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4 |
traps OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.0 |
rebootStartedThe reboot process has started NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.1 |
rebootCompletedThe reboot process is complete NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.2 |
userLoginA user logged in NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.3 |
userLogoutA user logged out NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.4 |
userAuthenticationFailureA user authentication attempt failed NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.5 |
userSessionTimeoutA user timed out from the device NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.8 |
userAddedA user was added to the system NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.11 |
userModifiedA user account was modified NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.12 |
userDeletedA user was deleted from the system NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.13 |
groupAddedA group was added to the system NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.14 |
groupModifiedA group was modified NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.15 |
groupDeletedA group was deleted from the system NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.16 |
deviceUpdateStartedThe device update has started NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.20 |
userBlockedA blocked user tried to log in NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.22 |
powerControlAn outlet has been switched NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.23 |
userPasswordChangedA user password was changed NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.24 |
passwordSettingsChangedStrong password settings changed NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.28 |
firmwareFileDiscardedA firmware file discarded NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.36 |
firmwareValidationFailedA firmware validation failed NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.38 |
securityViolationSecurity violation. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.39 |
logFileClearedThe log file has been cleared. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.41 |
thresholdAlarmConfigured sensor theshold event. The 'thresholdEventType' variable will indicate whether or not the threshold triggered or cleared. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.45 |
outletGroupingConnectivityLostMaster PDU lost contact with the slave PDU in an outlet grouping configuration. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.50 |
circuitBreakerTrippedCircuit Breaker Tripped. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.51 |
circuitBreakerRecoveredCircuit Breaker Recovered. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.52 |
bulkConfigurationSavedBulk Configuration saved. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.53 |
bulkConfigurationCopiedBulk Configuration saved. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.54 |
environmentalSensorsConnectivityLostlost connectivity to environmental Sensors NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.55 |
externalOnOffSensorStateChangeExternal OnOff Sensor State Change. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.56 |
environmentalSensorsConnectivityRestoredconnectivity to environmental Sensor was restored NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.57 |
voltageMeasurementErrorvoltage measurement error, a Psoc (Outlet Controller) reported zero voltage and non-zero current. Voltage, power and energy measurements may be in error NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.58 |
fipsModeEnabledFIPS Mode Enabled NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.59 |
fipsModeDisabledFIPS Mode Disabled NOTIFICATION-TYPE .1.3.6.1.4.1.13742.4.0.60 |
board OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.1 |
info OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.1.1 |
firmwareVersionThe current firmware version in the following format: major.minor.dot.buildnumber. Example: 1.3.5.7416ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.1 |
serialNumberThe serial number.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.2 |
ipAddressThe current IP address. A value of 0.0.0.0 indicates an error or an unset option.ro IpAddress .1.3.6.1.4.1.13742.4.1.1.3 |
netmaskThe current Netmask. A value of 0.0.0.0 indicates an error or an unset option.ro IpAddress .1.3.6.1.4.1.13742.4.1.1.4 |
gatewayThe current Gateway. A value of 0.0.0.0 indicates an error or an unset option.ro IpAddress .1.3.6.1.4.1.13742.4.1.1.5 |
macThe current MAC address.ro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.6 |
hardwareRevThe hardware revision number.ro Integer32 .1.3.6.1.4.1.13742.4.1.1.7 |
userNameThe login of a user.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.10 |
objectNameThe model type of the devicero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.12 |
objectInstanceThe device name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.13 |
targetUserThe user record being operated onro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.14 |
groupNameThe group record being operated onro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.15 |
imageVersionThe version of the Upgrade imagero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.18 |
sensorDescrSensor description indicating which sensor experienced a threshold event. When applicable, the description will indicate the sensor number.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.19 |
thresholdDescrThreshold description indicating which configured threshold has been triggered (or cleared).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.20 |
thresholdSeverityString (Warning, Critical, etc...) indicating the severity of the threshold which has been triggered (or cleared).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.21 |
thresholdEventTypeString (triggered, cleared) indicating if the threshold event indicates that a configured threshold has been triggered or cleared.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.22 |
statusThe success status of an operationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.23 |
slaveIpAddressIn an outlet grouping configuration, this is the IP address of slave PDU. A value of 0.0.0.0 indicates an error or an unset option.ro IpAddress .1.3.6.1.4.1.13742.4.1.1.24 |
inputCurrentRatingThe input current Ratingro MilliAmps .1.3.6.1.4.1.13742.4.1.1.25 |
ratedVoltagePDU Rated Voltagero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.26 |
ratedPowerPDU Rated Powerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.27 |
outletSwitchingOutlet switching: enabled/disabled; for non-switched PDUs, this value can be read, but cannot be writtenrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.28 |
dataLoggingData Retrieval: enabled/disabledrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.29 |
dataLoggingIntervalData Logging periodicity in seconds. This is the periodicity of the data in the buffer. This value must be a multiple of 3 between 3 and 600. For example, 60 is valid, but 64 is not valid This is being deprecated in favor of measurementsPerLogEntry. The mapping is as follows. dataLoggingInterval measurementsPerLogEntry 3n n Example: dataLoggingInterval is 60, so every 60 seconds (or 20th sample) data will be placed in the data log measurementsPerLogEntry is 20, so the data log sill store the minimum, average and maximum of every 20 samplesrwdeprecated Integer32 .1.3.6.1.4.1.13742.4.1.1.30 |
dataCollectionIntervalData Collection periodicity. This is the periodicity of the data collected by the PX. This value is fixed at 3 seconds.ro Integer32 .1.3.6.1.4.1.13742.4.1.1.31 |
outletEnergySupportOutlet Energy Support: Yes/No If the value is No, then outletWattHours and dataLogOutletWattHours will be zeroro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.32 |
currentUnbalanceSupportcurrent Unbalance calculations Supported: Yes/No If the value is No, then currentUnbalance will be zero Default is Norw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.33 |
externalSensorsZCoordinateUnitsExternal Sensor Z Coordinate units: Freeform or Rack Units (U) Default is Urw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.34 |
inlineMeterIs this unit an inline meter? Yes/No If Yes, then the folowing pairings hold: Inlet 1 <-> Outlet 1 Inlet 2 <-> Outlet 2 Inlet 3 <-> Outlet 3 Inlet 4 <-> Outlet 4 Use the inletTable to obtain inlet data Use the inletPoleTable to obtain the line data for an inlet.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.35 |
oldSensorStateThe old sensor state used in Sensor State Transition traps.ro StateOfSensorEnumeration .1.3.6.1.4.1.13742.4.1.1.36 |
externalSensorNumberA unique value for each sensor. Its value ranges between 1 and the value of externalSensorCount.ro Integer32 .1.3.6.1.4.1.13742.4.1.1.37 |
sensorIdentificationStringString that uniquely identifies the external sensor. Format is: SensorType,ChannelNumber,SensorSubtype,SerialNumber Example external temperature sensor: Temperature,,,AEI8160083 Example external smoke detection sensor: onOff,2,contact,AEJ8160085 Example outlet Current: rmsCurrent,,,ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.38 |
lastUpgradeStatusA bit string which indicates which the status of the last upgrade. A value of 1 for a bit position indicates that the corresponding upgrade failed. If all bits are zero, then the upgrade succeeded; otherwise check lastUpgradeErrorDescription for further information.ro Bits .1.3.6.1.4.1.13742.4.1.1.39 |
lastUpgradeTimestampThe time when the last upgrade completedro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.40 |
lastUpgradeErrorDescriptionString that describes the upgrade errror. This is an empty string if the upgrade succeeded. Format is Failed PSOCs: 1[O:1,2,3-7];3[O:6-9,10-12] This indicates that upgrade of psocs 1 and 3 failed and psoc1 affects outlets 1,2, 3-7 and psoc2 affects outlets 6-9,10-12ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.41 |
powerCIMStatusThe status of the Power CIM: on or offrw PowerCIMStatusEnumeration .1.3.6.1.4.1.13742.4.1.1.42 |
measurementsPerLogEntryThe number of measurements used for each entry in the log. 1<= Value <= 200 Default is 20 This is related to dataLoggingInterval as shown below dataLoggingInterval measurementsPerLogEntry 3n n Example: dataLoggingInterval is 60, so every 60 seconds (or 20th sample) data will be placed in the data log measurementsPerLogEntry is 20, so the data log sill store the minimum, average and maximum of every 20 samplesrw Integer32 .1.3.6.1.4.1.13742.4.1.1.43 |
psocNumberThe psoc (Outlet Controller) numberro Integer32 .1.3.6.1.4.1.13742.4.1.1.44 |
altitudeThe altitude (height above sea level) of the PDU in meters. 0 <= Value <= 3000; default value is 0 metersrw Integer32 .1.3.6.1.4.1.13742.4.1.1.45 |
configureAlertsThis is an operation. It has write-only semantics. GET operation will return the empty string. For SET operations, it configures alerts The format is a comma separated list of the following parameters. sensorClass, eventType, eventDirection, policyName For sensorclass: use the SensorClass eumeration For eventType: use the EventType enumeration For eventDirection: use the EventDirection enumeration For Policy Name: use the name of the policy; the Policy Name is case sensitive Note: setting this variable will overwrite the existing policy Example: if the External Temperature upper non-critical threshold is either asserted and deasserted, then execute the policy named multiple destinations the string would be 0,1,2,multiple destinationsrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.1.46 |
fipsModeThe fips mode: either enabled or disabled. The mode can be set (changed) only if both of the following conditions hold a) the user is admin b) snmpv3 is being used. Changing this mode will result in a reboot of the PX When the PX is in FIPS mode, the follwing conditions hold. a) FIPS approved algorithms must be used b) snmp v1 & v2c are not supported b) snmp v3 must be used with AES and SHA c) https must be used; http is not supported d) Radius authentication is not supported e) Ldaps must be used; ldap is not supported f) ipmi v2.0 must be usedrw EnabledDisabledEnumeration .1.3.6.1.4.1.13742.4.1.1.47 |
outlets OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.1.2 |
outletCountThe number of outlets (regardless of their current state) present on this pdu.ro Integer32 .1.3.6.1.4.1.13742.4.1.2.1 |
outletTableA list of outlet entries. The number of entries is given by the value of outletCount. SEQUENCE OF OutletEntryStruct .1.3.6.1.4.1.13742.4.1.2.2 |
outletEntryAn outlet entry containing objects at the for a particular outlet. OutletEntryStruct .1.3.6.1.4.1.13742.4.1.2.2.1 |
outletIndexA unique value for each outlet. Its value ranges between 1 and the value of outletCount. Integer32 .1.3.6.1.4.1.13742.4.1.2.2.1.1 |
outletLabelA textual string containing information about the outlet.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.2.2.1.2 |
outletOperationalStateA value for each outlet which describes the operational state of the outlet. It is also used to set the operational state of the outletrw Enumeration .1.3.6.1.4.1.13742.4.1.2.2.1.3 |
outletCurrentA unique value for the current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp)ro MilliAmps .1.3.6.1.4.1.13742.4.1.2.2.1.4 |
outletMaxCurrentA unique value for the max. current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp)ro MilliAmps .1.3.6.1.4.1.13742.4.1.2.2.1.5 |
outletVoltageA unique value for the voltage sensor attached to the outlet.This value is reported in millivolts (1/1000th of a volt)ro MilliVolts .1.3.6.1.4.1.13742.4.1.2.2.1.6 |
outletActivePowerA unique value for the active power sensor attached to the outlet. This value is reported in Watts.ro Watts .1.3.6.1.4.1.13742.4.1.2.2.1.7 |
outletApparentPowerA unique value for the apparent power sensor attached to the outlet. This value is reported in Volt-Ampsro VoltAmps .1.3.6.1.4.1.13742.4.1.2.2.1.8 |
outletPowerFactorA unique value for the power factor of the outlet. The reading represents a percentage in the range of 0% to 100%.ro PowerFactorPercentage .1.3.6.1.4.1.13742.4.1.2.2.1.9 |
outletCurrentUpperWarningThe value of the upper warning (non-critical) current threshold for the outlet. This value is reported in milliamps (1/1000th of an amp)rw MilliAmps .1.3.6.1.4.1.13742.4.1.2.2.1.20 |
outletCurrentUpperCriticalThe value of the upper critical current threshold for the outlet. This value is reported in milliamps (1/1000th of an amp)rw MilliAmps .1.3.6.1.4.1.13742.4.1.2.2.1.21 |
outletCurrentLowerWarningThe value of the lower warning (non-critical) current threshold for the outlet. This value is reported in milliamps (1/1000th of an amp)rw MilliAmps .1.3.6.1.4.1.13742.4.1.2.2.1.22 |
outletCurrentLowerCriticalThe value of the lower critical current threshold for the outlet. This value is reported in milliamps (1/1000th of an amp)rw MilliAmps .1.3.6.1.4.1.13742.4.1.2.2.1.23 |
outletCurrentHysteresisThe hysteresis used for deassertionsrw Unsigned32 .1.3.6.1.4.1.13742.4.1.2.2.1.24 |
outletCurrentRatingThe current rating of the outlet. This value is reported in milliamps (1/1000th of an amp)ro MilliAmps .1.3.6.1.4.1.13742.4.1.2.2.1.30 |
outletWattHoursThe value of the cumulative active energy for this outlet. This value is reported in WattHoursro WattHours .1.3.6.1.4.1.13742.4.1.2.2.1.31 |
unit OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.1.3 |
unitReadings OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.1.3.1 |
unitCurrentThe value for the unit's current sensor in millamps.This object is deprecated in favour of lineCurrent corresponding to lineCurrentLabel = L1rodeprecated MilliAmps .1.3.6.1.4.1.13742.4.1.3.1.1 |
unitVoltageThe value for the unit's voltage sensor in millivolts.This object is deprecated in favour of lineVoltage corresponding to lineVoltageLabel = L1rodeprecated MilliVolts .1.3.6.1.4.1.13742.4.1.3.1.2 |
unitActivePowerThe value for the unit's active power in watts.This object is deprecated in favour of inletTable.inletActivePowerrodeprecated Watts .1.3.6.1.4.1.13742.4.1.3.1.3 |
unitApparentPowerThe value for the unit's apparent power in volt-amps. This object is deprecated in favour of inletTable.inletApparentPowerrodeprecated VoltAmps .1.3.6.1.4.1.13742.4.1.3.1.4 |
unitCpuTempThe value for the unit's CPU temperature sensor in tenth degrees celsius.ro TenthDegreesCelsius .1.3.6.1.4.1.13742.4.1.3.1.5 |
unitVoltageLowerWarningThe value of the lower warning (non-critical) unit level voltage threshold.This object is deprecated in favour of unitOrLineVoltageLowerWarningrwdeprecated MilliVolts .1.3.6.1.4.1.13742.4.1.3.1.60 |
unitVoltageLowerCriticalThe value of the lower critical unit level voltage threshold.This object is deprecated in favour of unitOrLineVoltageLowerCriticalrwdeprecated MilliVolts .1.3.6.1.4.1.13742.4.1.3.1.61 |
unitVoltageUpperWarningThe value of the upper warning (non-critical) unit level voltage threshold.This object is deprecated in favour of unitOrLineVoltageUpperWarningrwdeprecated MilliVolts .1.3.6.1.4.1.13742.4.1.3.1.62 |
unitVoltageUpperCriticalThe value of the upper critical unit level voltage threshold.This object is deprecated in favour of unitOrLineVoltageUpperCriticalrwdeprecated MilliVolts .1.3.6.1.4.1.13742.4.1.3.1.63 |
unitCurrentUpperWarningThe value of the upper warning (non-critical) unit level current threshold.This object is deprecated in favour of unitOrLineCurrentUpperWarningrwdeprecated MilliAmps .1.3.6.1.4.1.13742.4.1.3.1.70 |
unitCurrentUpperCriticalThe value of the upper critical unit level current threshold. NOTE: This particular threshold is NOT settable. This object is deprecated in favour of unitOrLineCurrentUpperCriticarodeprecated MilliAmps .1.3.6.1.4.1.13742.4.1.3.1.71 |
unitTempLowerWarningThe value of the lower warning (non-critical) unit level temperature threshold.rw DegreesCelsius .1.3.6.1.4.1.13742.4.1.3.1.80 |
unitTempLowerCriticalThe value of the lower critical unit level temperature threshold.rw DegreesCelsius .1.3.6.1.4.1.13742.4.1.3.1.81 |
unitTempUpperWarningThe value of the upper warning (non-critical) unit level temperature threshold.rw DegreesCelsius .1.3.6.1.4.1.13742.4.1.3.1.82 |
unitTempUpperCriticalThe value of the upper critical unit level temperature threshold.rw DegreesCelsius .1.3.6.1.4.1.13742.4.1.3.1.83 |
currentUnbalanceA string displaying the current unbalance in percent. It will have the value NA if the feature is disabled, the PX is not a 3-phase unit,or the average of the line currents is zeroro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.3.1.84 |
currentUnbalanceUpperWarningThe value of the upper warning (non-critical) current unbalance threshold.rw Percentage .1.3.6.1.4.1.13742.4.1.3.1.85 |
currentUnbalanceUpperCriticalThe value of the upper critical current Unbalance threshold.rw Percentage .1.3.6.1.4.1.13742.4.1.3.1.86 |
unitOrLineVoltageLowerWarningThe value of the lower warning (non-critical) unit level voltage threshold.rw MilliVolts .1.3.6.1.4.1.13742.4.1.3.1.90 |
unitOrLineVoltageLowerCriticalThe value of the lower critical unit level voltage threshold.rw MilliVolts .1.3.6.1.4.1.13742.4.1.3.1.91 |
unitOrLineVoltageUpperWarningThe value of the upper warning (non-critical) unit level voltagerw MilliVolts .1.3.6.1.4.1.13742.4.1.3.1.92 |
unitOrLineVoltageUpperCriticalThe value of the upper critical unit level voltage threshold.rw MilliVolts .1.3.6.1.4.1.13742.4.1.3.1.93 |
unitOrLineCurrentUpperWarningThe value of the upper warning (non-critical) unit level current thresholdrw MilliAmps .1.3.6.1.4.1.13742.4.1.3.1.94 |
unitOrLineCurrentUpperCriticalThe value of the upper critical unit level current threshold.rw MilliAmps .1.3.6.1.4.1.13742.4.1.3.1.95 |
neutralCurrentUpperWarningThe value of the upper warning (non-critical) threshold for the neutral currentrw MilliAmps .1.3.6.1.4.1.13742.4.1.3.1.96 |
neutralCurrentUpperCriticalThe value of the upper critical threshold for the neutral current.rw MilliAmps .1.3.6.1.4.1.13742.4.1.3.1.97 |
unitOrLineCurrentHysteresisThe hysteresis used for deassertionsrw Unsigned32 .1.3.6.1.4.1.13742.4.1.3.1.98 |
unitOrLineVoltageHysteresisThe hysteresis used for deassertionsrw Unsigned32 .1.3.6.1.4.1.13742.4.1.3.1.99 |
unitTempHysteresisThe hysteresis used for deassertionsrw Unsigned32 .1.3.6.1.4.1.13742.4.1.3.1.100 |
currentUnbalanceHysteresisThe hysteresis used for deassertionsrw Unsigned32 .1.3.6.1.4.1.13742.4.1.3.1.101 |
lineCurrents OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.1.4 |
lineCurrentCountThe number of line currents (1 for single phase, 3 for 3 phase Delta-wired, 4 for 3 phase WYE wired).This object is deprecated in favour of inletPoleTablerodeprecated Integer32 .1.3.6.1.4.1.13742.4.1.4.1 |
lineCurrentTableA list of line input entries. The number of entries is given by the value of lineInputCount. This object is deprecated in favour of inletPoleTabledeprecated SEQUENCE OF LineCurrentEntryStruct .1.3.6.1.4.1.13742.4.1.4.2 |
lineCurrentEntryAn entry containing values and threshold settings for a particular line input.This object is deprecated in favour of inletPoleTabledeprecated LineCurrentEntryStruct .1.3.6.1.4.1.13742.4.1.4.2.1 |
lineCurrentIndexA unique value for each line input. Its value ranges between 1 and lineInputCount. This object is deprecated in favour of inletPoleTabledeprecated Integer32 .1.3.6.1.4.1.13742.4.1.4.2.1.1 |
lineCurrentLabelA string identifying the Line For Single Phase: L1 For 3phase Delta wired outlets: L1, L2, L3 For 3phase WYE Wired Outlets: L1, L2, L3, N This object is deprecated in favour of inletPoleTablerodeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.4.2.1.2 |
lineCurrentThe value of the current reported in MilliAmps. This object is deprecated in favour of inletPoleTablerodeprecated MilliAmps .1.3.6.1.4.1.13742.4.1.4.2.1.3 |
circuitBreaker OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.1.5 |
circuitBreakerCountThe number of circuit breakers.ro Integer32 .1.3.6.1.4.1.13742.4.1.5.1 |
circuitBreakerTableA list of line input entries. The number of entries is given by the value of lineInputCount. SEQUENCE OF CircuitBreakerEntryStruct .1.3.6.1.4.1.13742.4.1.5.2 |
circuitBreakerEntryAn entry containing values and threshold settings for a particular line input. CircuitBreakerEntryStruct .1.3.6.1.4.1.13742.4.1.5.2.1 |
circuitBreakerIndexA unique value for each circuit breaker. Its value ranges between 1 and circuitBreakerCount. Integer32 .1.3.6.1.4.1.13742.4.1.5.2.1.1 |
circuitBreakerLabelA string identifying the circuit breakerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.5.2.1.2 |
circuitBreakerStateThe value for the circuit breaker state .ro Enumeration .1.3.6.1.4.1.13742.4.1.5.2.1.3 |
circuitBreakerCurrentRatingThe value of the circuit breaker current rating in MilliAmps.ro MilliAmps .1.3.6.1.4.1.13742.4.1.5.2.1.4 |
circuitBreakerCurrentThe value of the current reported in MilliAmps.ro MilliAmps .1.3.6.1.4.1.13742.4.1.5.2.1.5 |
circuitBreakerCurrentUpperWarningThe value of the upper warning (non-critical) threshold.rw MilliAmps .1.3.6.1.4.1.13742.4.1.5.2.1.7 |
circuitBreakerCurrentUpperCriticalThe value of the upper critical threshold.rw MilliAmps .1.3.6.1.4.1.13742.4.1.5.2.1.9 |
circuitBreakerCurrentHysteresisThe hysteresis used for deassertionsrw Unsigned32 .1.3.6.1.4.1.13742.4.1.5.2.1.10 |
lineVoltages OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.1.6 |
lineVoltageCountThe number of line voltages (1 for single phase, 3 for 3 phase. This object is deprecated in favour of inletPoleTablerodeprecated Integer32 .1.3.6.1.4.1.13742.4.1.6.1 |
lineVoltageTableA list of line input entries. The number of entries is given by the value of lineInputCount. This object is deprecated in favour of linletPoleTabledeprecated SEQUENCE OF LineVoltageEntryStruct .1.3.6.1.4.1.13742.4.1.6.2 |
lineVoltageEntryAn entry containing values and threshold settings for a particular line input. This object is deprecated in favour of inletPoleTabledeprecated LineVoltageEntryStruct .1.3.6.1.4.1.13742.4.1.6.2.1 |
lineVoltageIndexA unique value for each line input. Its value ranges between 1 and lineInputCount. This object is deprecated in favour of inletPoleTabledeprecated Integer32 .1.3.6.1.4.1.13742.4.1.6.2.1.1 |
lineVoltageLabelA string identifying the Line For Single Phase: L1 For 3phase Delta-wired: L1-L2, L2-L3, L3-L1 For 3phase Wye-wired: L1-N, L2-N, L3-N This object is deprecated in favour of inletPoleTablerodeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.6.2.1.2 |
lineVoltageThe value of the voltage reported in MilliVolts. This object is deprecated in favour of inletPoleTablerodeprecated MilliVolts .1.3.6.1.4.1.13742.4.1.6.2.1.3 |
dataLog OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.1.7 |
dataLogCountThe number of entries in the dataLog table which is a circular buffer.ro Integer32 .1.3.6.1.4.1.13742.4.1.7.1 |
dataLogLatestIndexThe index of the latest (most recent) entry in dataLogTable .ro Integer32 .1.3.6.1.4.1.13742.4.1.7.2 |
dataLogTableA list of data log entries. The number of entries is given by the value of dataLogCount. SEQUENCE OF DataLogEntryStruct .1.3.6.1.4.1.13742.4.1.7.3 |
dataLogEntryAn entry in the dataLog buffer containing the unit data collected at the instant specified by dataLogTimeStamp DataLogEntryStruct .1.3.6.1.4.1.13742.4.1.7.3.1 |
dataLogIndexA unique value for each data sample. Its value ranges between 1 and dataLogCount . Integer32 .1.3.6.1.4.1.13742.4.1.7.3.1.1 |
dataLogTimeStampThe time when the data was collected. It is measured in seconds relative to January 1, 1970 (midnight UTC/GMT), i.e a value of 0 indicates January 1, 1970 (midnight UTC/GMT)ro Unsigned32 .1.3.6.1.4.1.13742.4.1.7.3.1.2 |
dataLogActivePowerThe value for the pdu's active power sensor in watts. This has been deprecated in favor of dataLogAvgActivePower, dataLogMaxActivePower,dataLogMinActivePowerrodeprecated Watts .1.3.6.1.4.1.13742.4.1.7.3.1.3 |
dataLogApparentPowerThe value for the pdu's apparent power sensor in volt-amps. This has been deprecated in favor of dataLogAvgApparentPower, dataLogMaxApparentPower,dataLogMinApparentPowerrodeprecated VoltAmps .1.3.6.1.4.1.13742.4.1.7.3.1.4 |
dataLogAvgActivePowerThe average active power for this measurement periodro Watts .1.3.6.1.4.1.13742.4.1.7.3.1.5 |
dataLogMaxActivePowerThe maximum active power for this measurement periodro Watts .1.3.6.1.4.1.13742.4.1.7.3.1.6 |
dataLogMinActivePowerThe minimum active power for this measurement periodro Watts .1.3.6.1.4.1.13742.4.1.7.3.1.7 |
dataLogAvgApparentPowerThe average apparent power for this measurement periodro VoltAmps .1.3.6.1.4.1.13742.4.1.7.3.1.8 |
dataLogMaxApparentPowerThe maximum apparent power for this measurement periodro VoltAmps .1.3.6.1.4.1.13742.4.1.7.3.1.9 |
dataLogMinApparentPowerThe minimum apparent power for this measurement periodro VoltAmps .1.3.6.1.4.1.13742.4.1.7.3.1.10 |
dataLogOutlet OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.1.10 |
dataLogOutletTableA list of outlet entries. The number of entries is given by the value of outletCount. SEQUENCE OF DataLogOutletEntryStruct .1.3.6.1.4.1.13742.4.1.10.1 |
dataLogOutletEntryAn entry in the data log containing outlet level data for a particular outlet. DataLogOutletEntryStruct .1.3.6.1.4.1.13742.4.1.10.1.1 |
dataLogOutletIndexA unique value for each outlet. Its value ranges between 1 and the value of outletCount. Integer32 .1.3.6.1.4.1.13742.4.1.10.1.1.1 |
dataLogOutletCurrentA unique value for the current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp) This has been deprecated in favor of dataLogAvgOutletCurrent , dataLogMaxOutletCurrent ,dataLogMinOutletCurrentrodeprecated MilliAmps .1.3.6.1.4.1.13742.4.1.10.1.1.2 |
dataLogOutletVoltageA unique value for the voltage sensor attached to the outlet.This value is reported in millivolts (1/1000th of a volt) This has been deprecated in favor of dataLogAvgOutletVoltage , dataLogMaxOutletVoltage ,dataLogMinOutletVoltagerodeprecated MilliVolts .1.3.6.1.4.1.13742.4.1.10.1.1.3 |
dataLogOutletPowerFactorA unique value for the power factor of the outlet. The reading represents a percentage in the range of 0% to 100%. This has been deprecated in favor of dataLogAvgOutletPowerFactor, dataLogMaxOutletPowerFactor,dataLogMinOutletPowerFactorrodeprecated PowerFactorPercentage .1.3.6.1.4.1.13742.4.1.10.1.1.4 |
dataLogOutletOnTimeThe amount of time since this outlet was last switched on. This value is reported in seconds.ro Unsigned32 .1.3.6.1.4.1.13742.4.1.10.1.1.5 |
dataLogOutletWattHoursThe cumulative Active Energy for this outlet. This value is reported in WattHours This has been deprecated in favor of dataLogAvgOutletWattHours , dataLogMaxOutletWattHours ,dataLogMinOutletWattHoursrodeprecated WattHours .1.3.6.1.4.1.13742.4.1.10.1.1.6 |
dataLogAvgOutletCurrentThe Average value for the measurement period: A unique value for the current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp)ro MilliAmps .1.3.6.1.4.1.13742.4.1.10.1.1.7 |
dataLogMaxOutletCurrentThe Maximum value for the measurement period: A unique value for the current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp)ro MilliAmps .1.3.6.1.4.1.13742.4.1.10.1.1.8 |
dataLogMinOutletCurrentThe Minimum value for the measurement period: A unique value for the current sensor attached to the outlet. This value is reported in milliamps (1/1000th of an amp)ro MilliAmps .1.3.6.1.4.1.13742.4.1.10.1.1.9 |
dataLogAvgOutletVoltageThe Average value for the measurement period: A unique value for the voltage sensor attached to the outlet.This value is reported in millivolts (1/1000th of a volt)ro MilliVolts .1.3.6.1.4.1.13742.4.1.10.1.1.10 |
dataLogMaxOutletVoltageThe Maximum value for the measurement period: A unique value for the voltage sensor attached to the outlet.This value is reported in millivolts (1/1000th of a volt)ro MilliVolts .1.3.6.1.4.1.13742.4.1.10.1.1.11 |
dataLogMinOutletVoltageThe Minimum value for the measurement period: A unique value for the voltage sensor attached to the outlet.This value is reported in millivolts (1/1000th of a volt)ro MilliVolts .1.3.6.1.4.1.13742.4.1.10.1.1.12 |
dataLogAvgOutletPowerFactorThe Average value for the measurement period: A unique value for the power factor of the outlet. The reading represents a percentage in the range of 0% to 100%ro PowerFactorPercentage .1.3.6.1.4.1.13742.4.1.10.1.1.13 |
dataLogMaxOutletPowerFactorThe Maximum value for the measurement period: A unique value for the power factor of the outlet. The reading represents a percentage in the range of 0% to 100%ro PowerFactorPercentage .1.3.6.1.4.1.13742.4.1.10.1.1.14 |
dataLogMinOutletPowerFactorThe Minimum value for the measurement period: A unique value for the power factor of the outlet. The reading represents a percentage in the range of 0% to 100%ro PowerFactorPercentage .1.3.6.1.4.1.13742.4.1.10.1.1.15 |
dataLogAvgOutletWattHoursThe Average value for the measurement period: The cumulative Active Energy for this outlet. This value is reported in WattHoursro WattHours .1.3.6.1.4.1.13742.4.1.10.1.1.16 |
dataLogMaxOutletWattHoursThe Maximum value for the measurement period: The cumulative Active Energy for this outlet. This value is reported in WattHoursro WattHours .1.3.6.1.4.1.13742.4.1.10.1.1.17 |
dataLogMinOutletWattHoursThe Minimum value for the measurement period: The cumulative Active Energy for this outlet. This value is reported in WattHoursro WattHours .1.3.6.1.4.1.13742.4.1.10.1.1.18 |
dataLogInlet OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.1.12 |
dataLogInletTableA list of inlet entries. The number of entries is given by the value of inletCount. SEQUENCE OF DataLogInletEntryStruct .1.3.6.1.4.1.13742.4.1.12.2 |
dataLogInletEntryAn inlet entry containing objects at the for a particular outlet. DataLogInletEntryStruct .1.3.6.1.4.1.13742.4.1.12.2.1 |
dataLogInletIndexA unique value for each inlet. Its value ranges between 1 and the value of inletCount. Integer32 .1.3.6.1.4.1.13742.4.1.12.2.1.1 |
dataLogInletCurrentUnbalanceA string displaying the current unbalance in percent. It will have the value NA if the feature is disabled, the PX is not a 3-phase unit,or the average of the line currents is zero This has been deprecated in favor of dataLogAvgInletCurrentUnbalance, dataLogMaxInletCurrentUnbalance, dataLogMinInletCurrentUnbalancerodeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.12.2.1.10 |
dataLogInletActivePowerThe active power for the inlet This value is reported in Watts. This has been deprecated in favor of dataLogAvgInletActivePower, dataLogMaxInletActivePower, dataLogMinInletActivePowerrodeprecated Watts .1.3.6.1.4.1.13742.4.1.12.2.1.11 |
dataLogInletApparentPowerThe apparent power for the inlet. This value is reported in Volt-Amps This has been deprecated in favor of dataLogAvgInletApparentPower, dataLogMaxInletApparentPower, dataLogMinInletApparentPowerrodeprecated VoltAmps .1.3.6.1.4.1.13742.4.1.12.2.1.12 |
dataLogInletActiveEnergyThe value of the cumulative active energy for this inlet. This value is reported in WattHours This has been deprecated in favor of dataLogAvgInletActiveEnergy, dataLogMaxInletActiveEnergy, dataLogMinInletActiveEnergyrodeprecated WattHours .1.3.6.1.4.1.13742.4.1.12.2.1.13 |
dataLogAvgInletCurrentUnbalanceThe average value of the current unbalance for this measurement period A string displaying the current unbalance in percent. It will have the value NA if the feature is disabled, the PX is not a 3-phase unit,or the average of the line currents is zeroro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.12.2.1.14 |
dataLogMaxInletCurrentUnbalanceThe Maximum value for the measurement period: A string displaying the current unbalance in percent. It will have the value NA if the feature is disabled, the PX is not a 3-phase unit,or the average of the line currents is zeroro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.12.2.1.15 |
dataLogMinInletCurrentUnbalanceThe Minimum value for the measurement period: A string displaying the current unbalance in percent. It will have the value NA if the feature is disabled, the PX is not a 3-phase unit,or the average of the line currents is zeroro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.12.2.1.16 |
dataLogAvgInletActivePowerThe Average value for the measurement period: The active power for the inlet This value is reported in Watts.ro Watts .1.3.6.1.4.1.13742.4.1.12.2.1.17 |
dataLogMaxInletActivePowerThe Maximum value for the measurement period: The active power for the inlet This value is reported in Watts.ro Watts .1.3.6.1.4.1.13742.4.1.12.2.1.18 |
dataLogMinInletActivePowerThe Minimum value for the measurement period: The active power for the inlet This value is reported in Watts.ro Watts .1.3.6.1.4.1.13742.4.1.12.2.1.19 |
dataLogAvgInletApparentPowerThe Average value for the measurement period: The apparent power for the inlet. This value is reported in Volt-Ampsro VoltAmps .1.3.6.1.4.1.13742.4.1.12.2.1.20 |
dataLogMaxInletApparentPowerThe Maximum value for the measurement period: The apparent power for the inlet. This value is reported in Volt-Ampsro VoltAmps .1.3.6.1.4.1.13742.4.1.12.2.1.21 |
dataLogMinInletApparentPowerThe Minimum value for the measurement period: The apparent power for the inlet. This value is reported in Volt-Ampsro VoltAmps .1.3.6.1.4.1.13742.4.1.12.2.1.22 |
dataLogAvgInletActiveEnergyThe Average value for the measurement period: The value of the cumulative active energy for this inlet. This value is reported in WattHoursro WattHours .1.3.6.1.4.1.13742.4.1.12.2.1.23 |
dataLogMaxInletActiveEnergyThe Maximum value for the measurement period: The value of the cumulative active energy for this inlet. This value is reported in WattHoursro WattHours .1.3.6.1.4.1.13742.4.1.12.2.1.24 |
dataLogMinInletActiveEnergyThe Minimum value for the measurement period: The value of the cumulative active energy for this inlet. This value is reported in WattHoursro WattHours .1.3.6.1.4.1.13742.4.1.12.2.1.25 |
dataLogInletPole OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.1.13 |
dataLogInletPoleTableA list of line input entries. The number of entries is given by the value of dataLoginletTable(dataLogInletIndex).inletPoleCount. SEQUENCE OF DataLogInletPoleEntryStruct .1.3.6.1.4.1.13742.4.1.13.1 |
dataLogInletPoleEntryAn entry in the data log containing input line values for a particular input line. DataLogInletPoleEntryStruct .1.3.6.1.4.1.13742.4.1.13.1.1 |
dataLogInletPoleIndexA unique value for each line input. Its value ranges between 1 and lineCurrentCount. Integer32 .1.3.6.1.4.1.13742.4.1.13.1.1.1 |
dataLogInletPoleCurrentThe value of the current reported in MilliAmps. For Single Phase: Input Line Current For 3phase Delta-wired: Current for L1, L2, L3 For 3phase WYE-wired: Current for L1, L2, L3, N This has been deprecated in favor of dataLogAvgInletPoleCurrent, dataLogMaxInletPoleCurrent, dataLogMinInletPoleCurrentrodeprecated MilliAmps .1.3.6.1.4.1.13742.4.1.13.1.1.2 |
dataLogInletPoleVoltageThe value of the voltage reported in MilliVolts. For Single Phase: Input Line Voltage For 3phase Delta-wired: Voltages for L1-L2, L2-L3, L3-L1 For 3phase WYE-wired: Voltages for L1-N, L2-N, L3-N This has been deprecated in favor of dataLogAvgInletPoleVoltage, dataLogMaxInletPoleVoltage, dataLogMinInletPoleVoltagerodeprecated MilliVolts .1.3.6.1.4.1.13742.4.1.13.1.1.3 |
dataLogAvgInletPoleCurrentThe Average value for the measurement period: The value of the current reported in MilliAmps. For Single Phase: Input Line Current For 3phase Delta-wired: Current for L1, L2, L3 For 3phase WYE-wired: Current for L1, L2, L3, Nro MilliAmps .1.3.6.1.4.1.13742.4.1.13.1.1.4 |
dataLogMaxInletPoleCurrentThe Maximum value for the measurement period: The value of the current reported in MilliAmps. For Single Phase: Input Line Current For 3phase Delta-wired: Current for L1, L2, L3 For 3phase WYE-wired: Current for L1, L2, L3, Nro MilliAmps .1.3.6.1.4.1.13742.4.1.13.1.1.5 |
dataLogMinInletPoleCurrentThe Minimum value for the measurement period: The value of the current reported in MilliAmps. For Single Phase: Input Line Current For 3phase Delta-wired: Current for L1, L2, L3 For 3phase WYE-wired: Current for L1, L2, L3, Nro MilliAmps .1.3.6.1.4.1.13742.4.1.13.1.1.6 |
dataLogAvgInletPoleVoltageThe Average value for the measurement period: The value of the voltage reported in MilliVolts. For Single Phase: Input Line Voltage For 3phase Delta-wired: Voltages for L1-L2, L2-L3, L3-L1 For 3phase WYE-wired: Voltages for L1-N, L2-N, L3-Nro MilliVolts .1.3.6.1.4.1.13742.4.1.13.1.1.7 |
dataLogMaxInletPoleVoltageThe Maximum value for the measurement period: The value of the voltage reported in MilliVolts. For Single Phase: Input Line Voltage For 3phase Delta-wired: Voltages for L1-L2, L2-L3, L3-L1 For 3phase WYE-wired: Voltages for L1-N, L2-N, L3-Nro MilliVolts .1.3.6.1.4.1.13742.4.1.13.1.1.8 |
dataLogMinInletPoleVoltageThe Minimum value for the measurement period: The value of the voltage reported in MilliVolts. For Single Phase: Input Line Voltage For 3phase Delta-wired: Voltages for L1-L2, L2-L3, L3-L1 For 3phase WYE-wired: Voltages for L1-N, L2-N, L3-Nro MilliVolts .1.3.6.1.4.1.13742.4.1.13.1.1.9 |
dataLogAvgInletPoleActivePowerThe Average value for the measurement period: The active power for the inlet This value is reported in Watts.ro Watts .1.3.6.1.4.1.13742.4.1.13.1.1.10 |
dataLogMaxInletPoleActivePowerThe Maximum value for the measurement period: The active power for the inlet This value is reported in Watts.ro Watts .1.3.6.1.4.1.13742.4.1.13.1.1.11 |
dataLogMinInletPoleActivePowerThe Minimum value for the measurement period: The active power for the inlet This value is reported in Watts.ro Watts .1.3.6.1.4.1.13742.4.1.13.1.1.12 |
dataLogAvgInletPoleApparentPowerThe Average value for the measurement period: The apparent power for the inlet. This value is reported in Volt-Ampsro VoltAmps .1.3.6.1.4.1.13742.4.1.13.1.1.13 |
dataLogMaxInletPoleApparentPowerThe Maximum value for the measurement period: The apparent power for the inlet. This value is reported in Volt-Ampsro VoltAmps .1.3.6.1.4.1.13742.4.1.13.1.1.14 |
dataLogMinInletPoleApparentPowerThe Minimum value for the measurement period: The apparent power for the inlet. This value is reported in Volt-Ampsro VoltAmps .1.3.6.1.4.1.13742.4.1.13.1.1.15 |
dataLogAvgInletPoleActiveEnergyThe Average value for the measurement period: The value of the cumulative active energy for this inlet. This value is reported in WattHoursro WattHours .1.3.6.1.4.1.13742.4.1.13.1.1.16 |
dataLogMaxInletPoleActiveEnergyThe Maximum value for the measurement period: The value of the cumulative active energy for this inlet. This value is reported in WattHoursro WattHours .1.3.6.1.4.1.13742.4.1.13.1.1.17 |
dataLogMinInletPoleActiveEnergyThe Minimum value for the measurement period: The value of the cumulative active energy for this inlet. This value is reported in WattHoursro WattHours .1.3.6.1.4.1.13742.4.1.13.1.1.18 |
dataLogInputLine OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.1.14 |
dataLogInputLineTableA list of line input entries. The number of entries is given by the value of lineCurrentCount. This object is deprecated in favour of dataLogInletLineTabledeprecated SEQUENCE OF DataLogInputLineEntryStruct .1.3.6.1.4.1.13742.4.1.14.1 |
dataLogInputLineEntryAn entry in the data log containing input line values for a particular input line. This object is deprecated in favour of dataLogInletLineTabledeprecated DataLogInputLineEntryStruct .1.3.6.1.4.1.13742.4.1.14.1.1 |
dataLogInputLineIndexA unique value for each line input. Its value ranges between 1 and inletTable(inletIndex).inletPoleCount. This object is deprecated in favour of dataLogInletLineTabledeprecated Integer32 .1.3.6.1.4.1.13742.4.1.14.1.1.1 |
dataLogInputLineCurrentThe value of the current reported in MilliAmps. For Single Phase: Input Line Current For 3phase Delta-wired: Current for L1, L2, L3 For 3phase WYE-wired: Current for L1, L2, L3, N This object is deprecated in favour of dataLogInletLineTablerodeprecated MilliAmps .1.3.6.1.4.1.13742.4.1.14.1.1.2 |
dataLogInputLineVoltageThe value of the voltage reported in MilliVolts. For Single Phase: Input Line Voltage For 3phase Delta-wired: Voltages for L1-L2, L2-L3, L3-L1 For 3phase WYE-wired: Voltages for L1-N, L2-N, L3-N This object is deprecated in favour of dataLogInletLineTablerodeprecated MilliVolts .1.3.6.1.4.1.13742.4.1.14.1.1.3 |
dataLogCircuitBreaker OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.1.15 |
dataLogCircuitBreakerTableA list of circuit breaker entries. The number of entries is given by the value of circuitBreakerCount. SEQUENCE OF DataLogCircuitBreakerEntryStruct .1.3.6.1.4.1.13742.4.1.15.1 |
dataLogCircuitBreakerEntryAn entry in the data log containing circuit breaker values DataLogCircuitBreakerEntryStruct .1.3.6.1.4.1.13742.4.1.15.1.1 |
dataLogCircuitBreakerIndexA unique value for each circuit breaker. Its value ranges between 1 and circuitBreakerCount. Integer32 .1.3.6.1.4.1.13742.4.1.15.1.1.1 |
dataLogCircuitBreakerCurrentThe value of the current reported in MilliAmps. This has been deprecated in favor of dataLogAvgCircuitBreakerCurrent, dataLogMaxOutletCircuitBreakerCurrent, dataLogMinCircuitBreakerCurrentrodeprecated MilliAmps .1.3.6.1.4.1.13742.4.1.15.1.1.2 |
dataLogAvgCircuitBreakerCurrentThe Average value for the measurement period: The value of the current reported in MilliAmps.ro MilliAmps .1.3.6.1.4.1.13742.4.1.15.1.1.3 |
dataLogMaxCircuitBreakerCurrentThe Maximum value for the measurement period: The value of the current reported in MilliAmps.ro MilliAmps .1.3.6.1.4.1.13742.4.1.15.1.1.4 |
dataLogMinCircuitBreakerCurrentThe Minimum value for the measurement period: The value of the current reported in MilliAmps.ro MilliAmps .1.3.6.1.4.1.13742.4.1.15.1.1.5 |
inlets OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.1.20 |
inletCountThe number of inlets present on this pdu.ro Integer32 .1.3.6.1.4.1.13742.4.1.20.1 |
inletTableA list of inlet entries. The number of entries is given by the value of inletCount. SEQUENCE OF InletEntryStruct .1.3.6.1.4.1.13742.4.1.20.2 |
inletEntryAn inlet entry containing objects for each inlet InletEntryStruct .1.3.6.1.4.1.13742.4.1.20.2.1 |
inletIndexA unique value for each inlet. Its value ranges between 1 and the value of inletCount. Integer32 .1.3.6.1.4.1.13742.4.1.20.2.1.1 |
inletPoleCountThe number of poles for an inlet (1 for single phase, 3 for 3 phase Delta-wired, 4 for 3 phase WYE wired).ro Integer32 .1.3.6.1.4.1.13742.4.1.20.2.1.3 |
inletCurrentRatingThe input current Ratingro MilliAmps .1.3.6.1.4.1.13742.4.1.20.2.1.4 |
inletCurrentA unique value for the current sensor attached to the inlet. This value is reported in milliamps (1/1000th of an amp)ro MilliAmps .1.3.6.1.4.1.13742.4.1.20.2.1.7 |
inletVoltageA unique value for the voltage sensor attached to the intlet.This value is reported in millivolts (1/1000th of a volt)ro MilliVolts .1.3.6.1.4.1.13742.4.1.20.2.1.8 |
inletActivePowerThe active power for the inlet This value is reported in Watts.ro Watts .1.3.6.1.4.1.13742.4.1.20.2.1.9 |
inletApparentPowerThe apparent power for the inlet. This value is reported in Volt-Ampsro VoltAmps .1.3.6.1.4.1.13742.4.1.20.2.1.10 |
inletPowerFactorA unique value for the power factor of the inlet. The reading represents a percentage in the range of 0% to 100%.ro PowerFactorPercentage .1.3.6.1.4.1.13742.4.1.20.2.1.11 |
inletActiveEnergyThe value of the cumulative active energy for this inlet. This value is reported in WattHoursro WattHours .1.3.6.1.4.1.13742.4.1.20.2.1.12 |
inletCurrentUnbalanceA string displaying the current unbalance in percent. It will have the value NA if the feature is disabled, the PX is not a 3-phase unit,or the average of the line currents is zeroro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.20.2.1.15 |
inletCurrentUpperWarningThe value of the upper warning (non-critical) current threshold for the inlet. This value is reported in milliamps (1/1000th of an amp)rw MilliAmps .1.3.6.1.4.1.13742.4.1.20.2.1.20 |
inletCurrentUpperCriticalThe value of the upper critical current threshold for the inlet. This value is reported in milliamps (1/1000th of an amp)rw MilliAmps .1.3.6.1.4.1.13742.4.1.20.2.1.21 |
inletCurrentLowerWarningThe value of the lower warning (non-critical) current threshold for the inlet. This value is reported in milliamps (1/1000th of an amp)rw MilliAmps .1.3.6.1.4.1.13742.4.1.20.2.1.22 |
inletCurrentLowerCriticalThe value of the lower critical current threshold for the inlet. This value is reported in milliamps (1/1000th of an amp)rw MilliAmps .1.3.6.1.4.1.13742.4.1.20.2.1.23 |
inletVoltageUpperWarningThe value of the upper warning (non-critical) current threshold for the inlet. This value is reported in millivolts (1/1000th of an amp)rw MilliVolts .1.3.6.1.4.1.13742.4.1.20.2.1.24 |
inletVoltageUpperCriticalThe value of the upper critical current threshold for the inlet. This value is reported in millivolts (1/1000th of an amp)rw MilliVolts .1.3.6.1.4.1.13742.4.1.20.2.1.25 |
inletVoltageLowerWarningThe value of the lower warning (non-critical) current threshold for the inlet. This value is reported in millivolts (1/1000th of an amp)rw MilliVolts .1.3.6.1.4.1.13742.4.1.20.2.1.26 |
inletVoltageLowerCriticalThe value of the lower critical current threshold for the inlet. This value is reported in millivolts (1/1000th of an amp)rw MilliVolts .1.3.6.1.4.1.13742.4.1.20.2.1.27 |
inletCurrentUnbalanceUpperCriticalThe value of the upper critical current Unbalance threshold.rw Percentage .1.3.6.1.4.1.13742.4.1.20.2.1.28 |
inletCurrentUnbalanceUpperWarningThe value of the upper warning current Unbalance threshold.rw Percentage .1.3.6.1.4.1.13742.4.1.20.2.1.29 |
inletCurrentHysteresisThe hysteresis used for deassertionsrw Unsigned32 .1.3.6.1.4.1.13742.4.1.20.2.1.30 |
inletVoltageHysteresisThe hysteresis used for deassertionsrw Unsigned32 .1.3.6.1.4.1.13742.4.1.20.2.1.31 |
inletPole OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.1.21 |
inletPoleTableA list of line input entries. The number of entries is given by the value of inletTable(inletIndex).inletPoleCount. SEQUENCE OF InletPoleEntryStruct .1.3.6.1.4.1.13742.4.1.21.2 |
inletPoleEntryAn entry in the data log containing input line values for a particular input line. InletPoleEntryStruct .1.3.6.1.4.1.13742.4.1.21.2.1 |
inletPoleIndexA unique value for each line input. Its value ranges between 1 and of inletTable(inletIndex).inletPoleCount. Integer32 .1.3.6.1.4.1.13742.4.1.21.2.1.1 |
inletPoleLabelA string identifying the Line For Single Phase: L1 For 3phase Delta wired outlets: L1, L2, L3 For 3phase WYE Wired Outlets: L1, L2, L3ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.1.21.2.1.2 |
inletPoleCurrentThe value of the line current reported in MilliAmps. inletPoleIndex = 1; For Single Phase, Input Line Current; For 3-phase, L1 Current inletPoleIndex = 2; For 3-phase, L2 Current inletPoleIndex = 3; For 3-phase, L3 Currentro MilliAmps .1.3.6.1.4.1.13742.4.1.21.2.1.3 |
inletPoleVoltageThe value of the line-line voltage reported in MilliVolts. inletPoleIndex = 1; Single Phase Input Line Voltage 3-phase, L1-L2 Voltage or L1-N voltage inletPoleIndex = 2; 3-phase L2-L3 Voltage or L2-N voltage inletPoleaIndex = 3; 3-phase L3-L1 Voltage or L3-N voltagero MilliVolts .1.3.6.1.4.1.13742.4.1.21.2.1.4 |
inletPoleMaxCurrentA unique value for the max. current sensor attached to the inlet Pole. This value is reported in milliamps (1/1000th of an amp)ro MilliAmps .1.3.6.1.4.1.13742.4.1.21.2.1.5 |
inletPoleActivePowerA unique value for the active power for the line/pole. This value is available only for 3-phase inline meters; for all other cases, the value will be zero. This value is reported in Watts.ro Watts .1.3.6.1.4.1.13742.4.1.21.2.1.7 |
inletPoleApparentPowerA unique value for the apparent power for the line/pole. This value is available only for 3-phase inline meters; for all other cases, the value will be zero. This value is reported in Volt-Ampsro VoltAmps .1.3.6.1.4.1.13742.4.1.21.2.1.8 |
inletPolePowerFactorA unique value for the power factor of the inlet pole. The reading represents a percentage in the range of 0% to 100%.ro PowerFactorPercentage .1.3.6.1.4.1.13742.4.1.21.2.1.9 |
inletPoleActiveEnergyThe value of the cumulative active energy for this line/pole. This value is available only for 3-phase inline meters; for all other cases, the value will be zero. This value is reported in WattHoursro WattHours .1.3.6.1.4.1.13742.4.1.21.2.1.11 |
environmental OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.2 |
tempSensorCountThe number of external temperature sensors (regardless of their current state) present on this pdu. This is deprecated in favor of externalSensorsrodeprecated Integer32 .1.3.6.1.4.1.13742.4.2.1 |
tempSensorTableA list of temperature sensor entries. The number of entries is given by the value of tempSensorCount. This is deprecated in favor of externalSensorsdeprecated SEQUENCE OF TempSensorEntryStruct .1.3.6.1.4.1.13742.4.2.2 |
tempSensorEntryAn entry containing sensor reading and threshold settings for a particular temperature sensor. This is deprecated in favor of externalSensorsdeprecated TempSensorEntryStruct .1.3.6.1.4.1.13742.4.2.2.1 |
tempSensorIndexA unique value for each temperature sensor. Its value ranges between 1 and tempSensorCount. This is deprecated in favor of externalSensorsdeprecated Integer32 .1.3.6.1.4.1.13742.4.2.2.1.1 |
tempSensorLabelA settable human-readable label for the external temperature sensor. One possible use for this label is to convey sensor location. This is deprecated in favor of externalSensorsrwdeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.2.2.1.2 |
temperatureThe value of the external temperature sensor reported in tenth degrees celsius. This is deprecated in favor of externalSensorsrodeprecated TenthDegreesCelsius .1.3.6.1.4.1.13742.4.2.2.1.3 |
tempLowerWarningThe value of the lower warning (non-critical) threshold. This is deprecated in favor of externalSensorsrwdeprecated DegreesCelsius .1.3.6.1.4.1.13742.4.2.2.1.4 |
tempUpperWarningThe value of the upper warning (non-critical) threshold. This is deprecated in favor of externalSensorsrwdeprecated DegreesCelsius .1.3.6.1.4.1.13742.4.2.2.1.5 |
tempLowerCriticalThe value of the lower critical threshold. This is deprecated in favor of externalSensorsrwdeprecated DegreesCelsius .1.3.6.1.4.1.13742.4.2.2.1.6 |
tempUpperCriticalThe value of the upper critical threshold. This is deprecated in favor of externalSensorsrwdeprecated DegreesCelsius .1.3.6.1.4.1.13742.4.2.2.1.7 |
tempXCoordinateThe value of X coordinate in freeform with number of characters <= 24 This is deprecated in favor of externalSensorsrwdeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.2.2.1.8 |
tempYCoordinateThe value of Y coordinate in freeform with number of characters <= 24 This is deprecated in favor of externalSensorsrwdeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.2.2.1.9 |
tempZCoordinateThe value of Z coordinate in one of two formats: either freeform with number of characters <= 24 or in Z units so that 0 =< integer value <= 60 This is deprecated in favor of externalSensorsrwdeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.2.2.1.10 |
humiditySensorCountThe number of external humidity sensors (regardless of their current state) present on this pdu. This is deprecated in favor of externalSensorsrodeprecated Integer32 .1.3.6.1.4.1.13742.4.2.3 |
humiditySensorTableA list of humidity sensor entries. The number of entries is given by the value of humiditySensorCount. This is deprecated in favor of externalSensorsdeprecated SEQUENCE OF HumiditySensorEntryStruct .1.3.6.1.4.1.13742.4.2.4 |
humiditySensorEntryAn entry containing sensor reading and threshold settings for a particular humidity sensor. This is deprecated in favor of externalSensorsdeprecated HumiditySensorEntryStruct .1.3.6.1.4.1.13742.4.2.4.1 |
humiditySensorIndexA unique value for each humidity sensor. Its value ranges between 1 and humiditySensorCount. This is deprecated in favor of externalSensorsdeprecated Integer32 .1.3.6.1.4.1.13742.4.2.4.1.1 |
humiditySensorLabelA settable human-readable label for the external humidity sensor. One possible use for this label is to convey sensor location. This is deprecated in favor of externalSensorsrwdeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.2.4.1.2 |
humidityThe value of the external humidity sensor reported as relative humidity (a percentage). This is deprecated in favor of externalSensorsrodeprecated RelativeHumidity .1.3.6.1.4.1.13742.4.2.4.1.3 |
humidityLowerWarningThe value of the lower warning (non-critical) threshold. This is deprecated in favor of externalSensorsrwdeprecated RelativeHumidity .1.3.6.1.4.1.13742.4.2.4.1.4 |
humidityUpperWarningThe value of the upper warning (non-critical) threshold. This is deprecated in favor of externalSensorsrwdeprecated RelativeHumidity .1.3.6.1.4.1.13742.4.2.4.1.5 |
humidityLowerCriticalThe value of the lower critical threshold. This is deprecated in favor of externalSensorsrwdeprecated RelativeHumidity .1.3.6.1.4.1.13742.4.2.4.1.6 |
humidityUpperCriticalThe value of the upper critical threshold. This is deprecated in favor of externalSensorsrwdeprecated RelativeHumidity .1.3.6.1.4.1.13742.4.2.4.1.7 |
humidityXCoordinateThe value of X coordinate in freeform with number of characters <= 24 This is deprecated in favor of externalSensorsrwdeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.2.4.1.8 |
humidityYCoordinateThe value of Y coordinate in freeform with number of characters <= 24 This is deprecated in favor of externalSensorsrwdeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.2.4.1.9 |
humidityZCoordinateThe value of Z coordinate in one of two formats: either freeform with number of characters <= 24 or in Z units so that 0 =< integer value <= 60 This is deprecated in favor of externalSensorsrwdeprecated DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.2.4.1.10 |
externalSensors OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.3 |
externalSensorCountThe number of external sensorsro Integer32 .1.3.6.1.4.1.13742.4.3.1 |
reorderexternalSensorTableEntriesThis is an operation. It has write-only semantics. GET operation will return the empty string. For SET operations, it specifies the new order of the externalSensorTable entries. The format is a comma separated list specifying the new order of the existing table entries. n1,n2,n3,n4,n5,n6,n7,n8,n9,n10,n11,n12,n13,n14,n15,n16 where n1,n2,n3,n4,n5,n6,n7,n8,n9,n10,n11,n12,n13,n14,n15,n16 is a permuation of 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16 Note that this implies that each of the numbers 1-16 must appear exactly once For example, if the value is 16,3,6,9,1,2,4,5,7,8,10,11,12,14,13,15 then the table is rearranged so that the existing entries are moved as follows: Existing Position New Position 1 --> 5 2 --> 6 3 --> 2 4 --> 7 5 --> 8 6 --> 3 7 --> 9 8 --> 10 9 --> 4 10 --> 11 11 --> 12 12 --> 13 13 --> 15 14 --> 14 15 --> 16 16 --> 1rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.3.2 |
externalSensorTableA list of externalSensor entries. The number of entries is given by the value of externalSensorCount for the pdu. SEQUENCE OF ExternalSensorEntryStruct .1.3.6.1.4.1.13742.4.3.3 |
externalSensorEntryAn externalSensor entry containing objects at the for a particular PDU. ExternalSensorEntryStruct .1.3.6.1.4.1.13742.4.3.3.1 |
sensorIDA unique value for each sesnor. Its value ranges between 1 and the value of externalSensorCount. Integer32 .1.3.6.1.4.1.13742.4.3.3.1.1 |
externalSensorTypeThe type of sensorro TypeOfSensorEnumeration .1.3.6.1.4.1.13742.4.3.3.1.2 |
externalSensorSerialNumberThe sensor serial numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.3.3.1.3 |
externalSensorNameThe user given namerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.3.3.1.4 |
externalSensorChannelNumberThe channel number, applies only to contact sensors; -1 for other sensorsro Integer32 .1.3.6.1.4.1.13742.4.3.3.1.5 |
externalSensorXCoordinateThe X coordinaterw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.3.3.1.6 |
externalSensorYCoordinateThe Y coordinaterw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.3.3.1.7 |
externalSensorZCoordinateThe Z coordinaterw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.4.3.3.1.8 |
externalBinarySensorSubtypeThe subtype of the binary sensorro TypeOfSensorEnumeration .1.3.6.1.4.1.13742.4.3.3.1.9 |
externalSensorUnitsThe base units. Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensorsro SensorUnitsEnumeration .1.3.6.1.4.1.13742.4.3.3.1.16 |
externalSensorDecimalDigitsThe number of digits displayed to the right of the decimal point. Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensorsro Unsigned32 .1.3.6.1.4.1.13742.4.3.3.1.17 |
externalSensorLowerCriticalThresholdThe lower critical threshold The value of this OID variable should be scaled by externalSensorDecimalDigits. For example, if the value is 1 and externalSensorDecimalDigits is 2, then actual value is .01 Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensorsrw Integer32 .1.3.6.1.4.1.13742.4.3.3.1.31 |
externalSensorLowerWarningThresholdThe lower non-critical (warning) threshold The value of this OID variable should be scaled by externalSensorDecimalDigits. For example, if the value is 1 and externalSensorDecimalDigits is 2, then actual value is .01 Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensorsrw Integer32 .1.3.6.1.4.1.13742.4.3.3.1.32 |
externalSensorUpperCriticalThresholdThe upper critical threshold The value of this OID variable should be scaled by externalSensorDecimalDigits. For example, if the value is 1 and externalSensorDecimalDigits is 2, then actual value is .01 Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensorsrw Integer32 .1.3.6.1.4.1.13742.4.3.3.1.33 |
externalSensorUpperWarningThresholdThe upper non-critical (warning) threshold The value of this OID variable should be scaled by externalSensorDecimalDigits. For example, if the value is 1 and externalSensorDecimalDigits is 2, then actual value is .01 Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensorsrw Integer32 .1.3.6.1.4.1.13742.4.3.3.1.34 |
externalSensorHysteresisThe hysteresis used for deassertions The value of this OID variable should be scaled by externalSensorDecimalDigits. For example, if the value is 1 and externalSensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to onOff, trip, vibration, waterDetection, smokeDetection sensors.rw Unsigned32 .1.3.6.1.4.1.13742.4.3.3.1.35 |
externalSensorStateThe sensor statero StateOfSensorEnumeration .1.3.6.1.4.1.13742.4.3.3.1.40 |
externalSensorValueThe sensor reading Does not apply (gets will return 0) to onOff, trip, vibration, waterDetection, smokeDetection sensorsro Integer32 .1.3.6.1.4.1.13742.4.3.3.1.41 |
conformance OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.9 |
compliances OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.9.1 |
complianceThe requirements for conformance to the PDU-MIB. This is deprecated and the new compliance ComplianceRev1 has been addeddeprecated Unknown .1.3.6.1.4.1.13742.4.9.1.1 |
complianceRev1The requirements for conformance to the PDU-MIB. This is deprecated and the new compliance ComplianceRev2 has been addeddeprecated Unknown .1.3.6.1.4.1.13742.4.9.1.2 |
complianceRev2The requirements for conformance to the PDU-MIB. This is deprecated and the new compliance ComplianceRev3 has been addeddeprecated Unknown .1.3.6.1.4.1.13742.4.9.1.3 |
complianceRev3The requirements for conformance to the PDU-MIB.This is deprecated and the new compliance ComplianceRev4 has been addeddeprecated Unknown .1.3.6.1.4.1.13742.4.9.1.4 |
complianceRev4The requirements for conformance to the PDU-MIB. This is deprecated and the new compliance ComplianceRev5 has been addeddeprecated Unknown .1.3.6.1.4.1.13742.4.9.1.5 |
complianceRev5The requirements for conformance to the PDU-MIB. Unknown .1.3.6.1.4.1.13742.4.9.1.6 |
groups OBJECT IDENTIFIER .1.3.6.1.4.1.13742.4.9.2 |
infoGroupA collection of objects providing basic information about the pdu.deprecated Unknown .1.3.6.1.4.1.13742.4.9.2.1 |
outletsGroupA collection of objects providing basic information about the outlets, including sensor readings. Unknown .1.3.6.1.4.1.13742.4.9.2.2 |
unitSensorsGroupA collection of objects providing unit level sensor readings.This group is deprecated in favor of unitSensorsGroupRevdeprecated Unknown .1.3.6.1.4.1.13742.4.9.2.4 |
externalTemperatureGroupA collection of objects providing external temperature sensor readings and threshold settings. This group is deprecated in favor of the externalSensorsGroupdeprecated Unknown .1.3.6.1.4.1.13742.4.9.2.6 |
externalHumidityGroupA collection of objects providing external humidity sensor readings and threshold settings. This group is deprecated in favor of the externalSensorsGroupdeprecated Unknown .1.3.6.1.4.1.13742.4.9.2.7 |
trapsGroupA collection of traps. Unknown .1.3.6.1.4.1.13742.4.9.2.9 |
lineCurrentGroupA collection of objects describing the line inputs. This group is deprecated in favor of inletPoleGroupdeprecated Unknown .1.3.6.1.4.1.13742.4.9.2.10 |
circuitBreakerGroupA collection of objects describing the circuit breakers. Unknown .1.3.6.1.4.1.13742.4.9.2.11 |
lineVoltageGroupA collection of objects describing the line voltages. This group is deprecated in favor of inletPoleGroupdeprecated Unknown .1.3.6.1.4.1.13742.4.9.2.12 |
unitSensorsGroupRevA collection of objects providing unit level sensor readings.This group is deprecated in favor of unitSensorsGroupRev2deprecated Unknown .1.3.6.1.4.1.13742.4.9.2.13 |
dataLogGroupA collection of objects describing the pdu data. This group is being deprecated in favor of dataLogGroupRevdeprecated Unknown .1.3.6.1.4.1.13742.4.9.2.14 |
inletPoleGroupA collection of objects describing the inlet poles. Unknown .1.3.6.1.4.1.13742.4.9.2.15 |
inletsGroupA collection of objects providing basic information about the inlets, including sensor readings. Unknown .1.3.6.1.4.1.13742.4.9.2.16 |
dataLogGroupRevA collection of objects describing the pdu data. This group is being deprecated in favor of dataLogGroupRev2deprecated Unknown .1.3.6.1.4.1.13742.4.9.2.17 |
unitSensorsGroupRev2A collection of objects providing unit level sensor readings. Unknown .1.3.6.1.4.1.13742.4.9.2.18 |
externalSensorsGroupA collection of objects providing external sensor readings and configuration settings. Unknown .1.3.6.1.4.1.13742.4.9.2.20 |
dataLogGroupRev2A collection of objects describing the pdu data. Unknown .1.3.6.1.4.1.13742.4.9.2.21 |
infoGroupRev2A collection of objects providing basic information about the pdu. Unknown .1.3.6.1.4.1.13742.4.9.2.22 |