Home/Catalog/LHX-MIB

LHX-MIB

This MIB describes the SNMP functions of the Schroff Varistar LHX heat exchanger supported by Raritan devices.
Main OID:
raritan.1.3.6.1.4.1.13742
84
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

84 total
Object Name
raritanThis MIB describes the SNMP functions of the Schroff Varistar LHX heat exchanger supported by Raritan devices.
MODULE-IDENTITY
.1.3.6.1.4.1.13742
lhxgw
OBJECT IDENTIFIER
.1.3.6.1.4.1.13742.9
traps
OBJECT IDENTIFIER
.1.3.6.1.4.1.13742.9.0
trapInformation
OBJECT IDENTIFIER
.1.3.6.1.4.1.13742.9.0.0
deviceNameThe user-defined name for the Device.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.13742.9.0.0.1
deviceInetAddressTypeThe type of address formatro
InetAddressType (INET-ADDRESS-MIB)
.1.3.6.1.4.1.13742.9.0.0.2
deviceInetIPAddressThe current IP address. A value of 0.0.0.0 indicates an error or an unset option.ro
InetAddress (INET-ADDRESS-MIB)
.1.3.6.1.4.1.13742.9.0.0.3
lhxErrorCodeThe LHX error code (F1 - F25, EP).ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.13742.9.0.0.4
portIdA unique value for the physical port, the LHX controlller is connected to. Its value ranges between 1 and the value of portCount.ro
Integer32
.1.3.6.1.4.1.13742.9.0.0.5
probeIdThe physical Sensor ID (F1 - F7).ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.13742.9.0.0.6
fanIdThe Fan ID (M1 - M6).ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.13742.9.0.0.7
powerSupplyIdThe Power Supply ID (1, 2).ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.13742.9.0.0.8
oldSensorStateThe old sensor state used in Sensor State Transition traps.ro
SensorStateEnumeration
.1.3.6.1.4.1.13742.9.0.0.9
sensorTypeIdA unique value for the type of sensor.ro
GwSensorTypeEnumeration
.1.3.6.1.4.1.13742.9.0.0.10
sensorIdA unique value for each sensor. Its value ranges between 1 and the value of sensorCount.ro
Integer32
.1.3.6.1.4.1.13742.9.0.0.11
oldOperationalStateThe old operational state used in Operational State Transition traps.ro
OperationalStateEnumeration
.1.3.6.1.4.1.13742.9.0.0.12
agentInetPortNumberThe UDP port number used for accessing the SNMP agent on the device. Examples: If the associated device MIB (PX2-MIB, EMD-MIB) has deviceCascadeType set to portForwarding, then master: 50500 slave 1:50501 slave 2: 50502 ...... If cascading mode is not portForwarding and default (Standard) ports are being used, then port: 161ro
InetPortNumber (INET-ADDRESS-MIB)
.1.3.6.1.4.1.13742.9.0.0.13
lhxSensorFailureA sensor failure (broken or short circuit) occurred.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.1
lhxFanFailureA fan motor failure occurred.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.2
lhxPowerSupplyFailureA power supply failure occurred.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.3
lhxThresholdAirOutletThe air outlet temperature threshold was crossed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.4
lhxThresholdAirInletThe air inlet temperature threshold was crossed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.5
lhxThresholdWaterInletThe water inlet temperature threshold was crossed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.6
lhxDoorOpenedThe door was opened.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.7
lhxMaximumCoolingRequestMaximum cooling was requested.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.8
lhxEmergencyCoolingEmergency cooling was activated.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.9
lhxWaterLeakWater leakage was detected.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.10
lhxThresholdHumidityThe humidity threshold was crossed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.11
lhxExternalWaterCoolingFailureAn external water cooling failure occurred.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.12
lhxThresholdWaterOutletThe water outlet temperature threshold was crossed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.13
lhxParameterDataLossData loss in parameter memory was detected.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.14
lhxStBusErrorAn ST-Bus communication error was detected.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.15
lhxCollectiveFaultAn error was detected.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.16
gwSensorStateChangeSensor State Change.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.17
gwLhxOperationalStateChangeOperational State Change.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.18
lhxVoltageLowThe supply voltage of an LHX became low.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.19
lhxBaseElectronicsFailureThe base electronics of an LHX controller failed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.20
lhxCondenserPumpFailureAn LHX condenser pump failed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.13742.9.0.21
configuration
OBJECT IDENTIFIER
.1.3.6.1.4.1.13742.9.1
portCountThe number of lhx units supported.ro
Integer32
.1.3.6.1.4.1.13742.9.1.1
sensorCountTableA list of lhx sensor count extries.
SEQUENCE OF SensorCountEntryStruct
.1.3.6.1.4.1.13742.9.1.2
sensorCountEntryAn entry containing the number of lhx sensors of a certain type.
SensorCountEntryStruct
.1.3.6.1.4.1.13742.9.1.2.1
sensorCountThe number of sensors.ro
Integer32
.1.3.6.1.4.1.13742.9.1.2.1.1
lhx
OBJECT IDENTIFIER
.1.3.6.1.4.1.13742.9.1.3
lhxConfigurationTableA list of lhx controller configuration extries. The number of entries is given by the value of portCount.
SEQUENCE OF LhxConfigurationEntryStruct
.1.3.6.1.4.1.13742.9.1.3.1
lhxConfigurationEntryAn entry containing parameters for an lhx.
LhxConfigurationEntryStruct
.1.3.6.1.4.1.13742.9.1.3.1.1
operationalStateThe operational state of the lhx controller. To switch LHX power state while controller is connected, set operationalState to 1 (off) or 2 (on). Switching power state while LHX is disconnected or to 0 (disconnected) is undefined.rw
OperationalStateEnumeration
.1.3.6.1.4.1.13742.9.1.3.1.1.1
setpointVentilatorsThe setpoint of the ventilators.rw
Integer32
.1.3.6.1.4.1.13742.9.1.3.1.1.2
setpointWaterValveThe setpoint of the water valve.rw
Integer32
.1.3.6.1.4.1.13742.9.1.3.1.1.3
defaultFanSpeedThe 'default' fan speed during normal operation in per mill. Default is 80% (= 800).rw
Integer32
.1.3.6.1.4.1.13742.9.1.3.1.1.4
maximumCoolingStateIndicates whether maximum cooling was requested or not. To request maximum cooling, set maximumCoolingState to 1 (true). Setting maximumCoolingState to 2 (false) is undefined, set alertState to 2 (false) instead.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.13742.9.1.3.1.1.5
alertStateIndicates whether LHX controler is in alert state or not. To acknowledge alert status, set alertState to 2 (false). Setting alertState to 1 (true) is undefined.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.13742.9.1.3.1.1.6
modelThe model indentifier of an LHX controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.13742.9.1.3.1.1.7
fwVersionThe firmware version of an LHX controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.13742.9.1.3.1.1.8
gwSensors
OBJECT IDENTIFIER
.1.3.6.1.4.1.13742.9.1.4
sensorConfigurationTableA list of lhx sensor configuration extries. The number of entries is given by the value of portCount.
SEQUENCE OF SensorConfigurationEntryStruct
.1.3.6.1.4.1.13742.9.1.4.1
sensorConfigurationEntryAn entry containing parameters for an lhx.
SensorConfigurationEntryStruct
.1.3.6.1.4.1.13742.9.1.4.1.1
portIdxA unique value for each port. Its value ranges between 1 and the value of portCount.
Integer32
.1.3.6.1.4.1.13742.9.1.4.1.1.1
sensorTypeIdxA unique value for the type of sensor.
Integer32
.1.3.6.1.4.1.13742.9.1.4.1.1.2
sensorIdxA unique value for each sensor. Its value ranges between 1 and the value of sensorCount.
Integer32
.1.3.6.1.4.1.13742.9.1.4.1.1.3
sensorLabelThe short ID of the sensor (e.g. F1, M2).ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.13742.9.1.4.1.1.4
sensorUnitThe base units. This parameter does not apply to state sensors.ro
SensorUnitsEnumeration
.1.3.6.1.4.1.13742.9.1.4.1.1.5
sensorDecimalDigitsThe number of digits displayed to the right of the decimal point. This parameter does not apply to state sensors.ro
Unsigned32
.1.3.6.1.4.1.13742.9.1.4.1.1.6
sensorMaximumThe largest possible value. The value of this OID variable should be scaled by sensorDecimalDigits. For example, if the value is 1 and sensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to state sensors.ro
Integer32
.1.3.6.1.4.1.13742.9.1.4.1.1.7
sensorMinimumThe smallest possible value. The value of this OID variable should be scaled by sensorDecimalDigits. For example, if the value is 1 and sensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to state sensors.ro
Integer32
.1.3.6.1.4.1.13742.9.1.4.1.1.8
sensorHysteresisThe hysteresis used for deassertions. The value of this OID variable should be scaled by sensorDecimalDigits. For example, if the value is 1 and sensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to state sensors.rw
Unsigned32
.1.3.6.1.4.1.13742.9.1.4.1.1.9
sensorLowerCriticalThresholdThe lower critical threshold. The value of this OID variable should be scaled by sensorDecimalDigits. For example, if the value is 1 and sensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to state sensors.rw
Integer32
.1.3.6.1.4.1.13742.9.1.4.1.1.10
sensorLowerWarningThresholdThe lower non-critical (warning) threshold. The value of this OID variable should be scaled by sensorDecimalDigits. For example, if the value is 1 and sensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to state sensors.rw
Integer32
.1.3.6.1.4.1.13742.9.1.4.1.1.11
sensorUpperCriticalThresholdThe upper critical threshold. The value of this OID variable should be scaled by sensorDecimalDigits. For example, if the value is 1 and sensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to state sensors.rw
Integer32
.1.3.6.1.4.1.13742.9.1.4.1.1.12
sensorUpperWarningThresholdThe upper non-critical (warning) threshold. The value of this OID variable should be scaled by sensorDecimalDigits. For example, if the value is 1 and sensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to state sensors.rw
Integer32
.1.3.6.1.4.1.13742.9.1.4.1.1.13
sensorEnabledThresholdsA bit string which indicates which thresholds are enabled. This parameter does not apply to state sensors.rw
Bits
.1.3.6.1.4.1.13742.9.1.4.1.1.14
sensorThresholdMaximumThe largest possible threshold value. The value of this OID variable should be scaled by sensorDecimalDigits. For example, if the value is 1 and sensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to state sensors.ro
Integer32
.1.3.6.1.4.1.13742.9.1.4.1.1.15
sensorThresholdMinimumThe smallest possible threshold value. The value of this OID variable should be scaled by sensorDecimalDigits. For example, if the value is 1 and sensorDecimalDigits is 2, then actual value is 0.01. This parameter does not apply to state sensors.ro
Integer32
.1.3.6.1.4.1.13742.9.1.4.1.1.16
sensorNameThe descriptive ID of the sensor (e.g. Fan Speed 1).ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.13742.9.1.4.1.1.17
measurements
OBJECT IDENTIFIER
.1.3.6.1.4.1.13742.9.2
sensorMeasurementsTableA list of external sensor entries. The number of entries is given by the value of sensorCount for the LHX.
SEQUENCE OF SensorMeasurementsEntryStruct
.1.3.6.1.4.1.13742.9.2.1
sensorMeasurementsEntryAn entry containing measurement objects for an external sensor.
SensorMeasurementsEntryStruct
.1.3.6.1.4.1.13742.9.2.1.1
measurementsSensorIsAvailableIs the sensor available?ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.13742.9.2.1.1.1
measurementsSensorStateThe sensor state.ro
SensorStateEnumeration
.1.3.6.1.4.1.13742.9.2.1.1.2
measurementsSensorValueThe sensor reading. This parameter does not apply to state sensors.ro
Integer32
.1.3.6.1.4.1.13742.9.2.1.1.3
measurementsSensorTimeStampThe sensor reading timestamp.ro
Unsigned32
.1.3.6.1.4.1.13742.9.2.1.1.4
conformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.13742.9.3
compliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.13742.9.3.1
groups
OBJECT IDENTIFIER
.1.3.6.1.4.1.13742.9.3.2
LHX-MIB - SNMP MIB Reference | MIBs Explorer