LHX-MIB
This MIB describes the SNMP functions of the Schroff Varistar LHX heat exchanger supported by Raritan devices.
Main OID:
raritan.1.3.6.1.4.1.13742
84
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
84 total| Object Name |
|---|
raritanThis MIB describes the SNMP functions of the
Schroff Varistar LHX heat exchanger
supported by Raritan devices. MODULE-IDENTITY .1.3.6.1.4.1.13742 |
lhxgw OBJECT IDENTIFIER .1.3.6.1.4.1.13742.9 |
traps OBJECT IDENTIFIER .1.3.6.1.4.1.13742.9.0 |
trapInformation OBJECT IDENTIFIER .1.3.6.1.4.1.13742.9.0.0 |
deviceNameThe user-defined name for the Device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.9.0.0.1 |
deviceInetAddressTypeThe type of address formatro InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.13742.9.0.0.2 |
deviceInetIPAddressThe current IP address. A value of 0.0.0.0 indicates an
error or an unset option.ro InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.13742.9.0.0.3 |
lhxErrorCodeThe LHX error code (F1 - F25, EP).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.9.0.0.4 |
portIdA unique value for the physical port, the LHX controlller
is connected to.
Its value ranges between 1 and the value of portCount.ro Integer32 .1.3.6.1.4.1.13742.9.0.0.5 |
probeIdThe physical Sensor ID (F1 - F7).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.9.0.0.6 |
fanIdThe Fan ID (M1 - M6).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.9.0.0.7 |
powerSupplyIdThe Power Supply ID (1, 2).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.9.0.0.8 |
oldSensorStateThe old sensor state used in Sensor State Transition traps.ro SensorStateEnumeration .1.3.6.1.4.1.13742.9.0.0.9 |
sensorTypeIdA unique value for the type of sensor.ro GwSensorTypeEnumeration .1.3.6.1.4.1.13742.9.0.0.10 |
sensorIdA unique value for each sensor. Its value
ranges between 1 and the value of sensorCount.ro Integer32 .1.3.6.1.4.1.13742.9.0.0.11 |
oldOperationalStateThe old operational state used in Operational State Transition traps.ro OperationalStateEnumeration .1.3.6.1.4.1.13742.9.0.0.12 |
agentInetPortNumberThe UDP port number used for accessing
the SNMP agent on the device.
Examples:
If the associated device MIB (PX2-MIB, EMD-MIB) has deviceCascadeType set to portForwarding, then
master: 50500
slave 1:50501
slave 2: 50502
......
If cascading mode is not portForwarding and default (Standard) ports are being used, then
port: 161ro InetPortNumber (INET-ADDRESS-MIB) .1.3.6.1.4.1.13742.9.0.0.13 |
lhxSensorFailureA sensor failure (broken or short circuit) occurred. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.1 |
lhxFanFailureA fan motor failure occurred. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.2 |
lhxPowerSupplyFailureA power supply failure occurred. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.3 |
lhxThresholdAirOutletThe air outlet temperature threshold was crossed. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.4 |
lhxThresholdAirInletThe air inlet temperature threshold was crossed. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.5 |
lhxThresholdWaterInletThe water inlet temperature threshold was crossed. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.6 |
lhxDoorOpenedThe door was opened. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.7 |
lhxMaximumCoolingRequestMaximum cooling was requested. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.8 |
lhxEmergencyCoolingEmergency cooling was activated. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.9 |
lhxWaterLeakWater leakage was detected. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.10 |
lhxThresholdHumidityThe humidity threshold was crossed. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.11 |
lhxExternalWaterCoolingFailureAn external water cooling failure occurred. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.12 |
lhxThresholdWaterOutletThe water outlet temperature threshold was crossed. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.13 |
lhxParameterDataLossData loss in parameter memory was detected. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.14 |
lhxStBusErrorAn ST-Bus communication error was detected. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.15 |
lhxCollectiveFaultAn error was detected. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.16 |
gwSensorStateChangeSensor State Change. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.17 |
gwLhxOperationalStateChangeOperational State Change. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.18 |
lhxVoltageLowThe supply voltage of an LHX became low. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.19 |
lhxBaseElectronicsFailureThe base electronics of an LHX controller failed. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.20 |
lhxCondenserPumpFailureAn LHX condenser pump failed. NOTIFICATION-TYPE .1.3.6.1.4.1.13742.9.0.21 |
configuration OBJECT IDENTIFIER .1.3.6.1.4.1.13742.9.1 |
portCountThe number of lhx units supported.ro Integer32 .1.3.6.1.4.1.13742.9.1.1 |
sensorCountTableA list of lhx sensor count extries. SEQUENCE OF SensorCountEntryStruct .1.3.6.1.4.1.13742.9.1.2 |
sensorCountEntryAn entry containing the number of lhx sensors of a certain type. SensorCountEntryStruct .1.3.6.1.4.1.13742.9.1.2.1 |
sensorCountThe number of sensors.ro Integer32 .1.3.6.1.4.1.13742.9.1.2.1.1 |
lhx OBJECT IDENTIFIER .1.3.6.1.4.1.13742.9.1.3 |
lhxConfigurationTableA list of lhx controller configuration extries.
The number of entries is given by the value of portCount. SEQUENCE OF LhxConfigurationEntryStruct .1.3.6.1.4.1.13742.9.1.3.1 |
lhxConfigurationEntryAn entry containing parameters for an lhx. LhxConfigurationEntryStruct .1.3.6.1.4.1.13742.9.1.3.1.1 |
operationalStateThe operational state of the lhx controller.
To switch LHX power state while controller is connected,
set operationalState to 1 (off) or 2 (on).
Switching power state while LHX is disconnected or to
0 (disconnected) is undefined.rw OperationalStateEnumeration .1.3.6.1.4.1.13742.9.1.3.1.1.1 |
setpointVentilatorsThe setpoint of the ventilators.rw Integer32 .1.3.6.1.4.1.13742.9.1.3.1.1.2 |
setpointWaterValveThe setpoint of the water valve.rw Integer32 .1.3.6.1.4.1.13742.9.1.3.1.1.3 |
defaultFanSpeedThe 'default' fan speed during normal operation in per mill.
Default is 80% (= 800).rw Integer32 .1.3.6.1.4.1.13742.9.1.3.1.1.4 |
maximumCoolingStateIndicates whether maximum cooling was requested or not.
To request maximum cooling, set maximumCoolingState to 1 (true).
Setting maximumCoolingState to 2 (false) is undefined,
set alertState to 2 (false) instead.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.13742.9.1.3.1.1.5 |
alertStateIndicates whether LHX controler is in alert state or not.
To acknowledge alert status, set alertState to 2 (false).
Setting alertState to 1 (true) is undefined.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.13742.9.1.3.1.1.6 |
modelThe model indentifier of an LHX controller.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.9.1.3.1.1.7 |
fwVersionThe firmware version of an LHX controller.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.9.1.3.1.1.8 |
gwSensors OBJECT IDENTIFIER .1.3.6.1.4.1.13742.9.1.4 |
sensorConfigurationTableA list of lhx sensor configuration extries.
The number of entries is given by the value of portCount. SEQUENCE OF SensorConfigurationEntryStruct .1.3.6.1.4.1.13742.9.1.4.1 |
sensorConfigurationEntryAn entry containing parameters for an lhx. SensorConfigurationEntryStruct .1.3.6.1.4.1.13742.9.1.4.1.1 |
portIdxA unique value for each port. Its value
ranges between 1 and the value of portCount. Integer32 .1.3.6.1.4.1.13742.9.1.4.1.1.1 |
sensorTypeIdxA unique value for the type of sensor. Integer32 .1.3.6.1.4.1.13742.9.1.4.1.1.2 |
sensorIdxA unique value for each sensor. Its value
ranges between 1 and the value of sensorCount. Integer32 .1.3.6.1.4.1.13742.9.1.4.1.1.3 |
sensorLabelThe short ID of the sensor (e.g. F1, M2).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.9.1.4.1.1.4 |
sensorUnitThe base units.
This parameter does not apply to state sensors.ro SensorUnitsEnumeration .1.3.6.1.4.1.13742.9.1.4.1.1.5 |
sensorDecimalDigitsThe number of digits displayed to the right of the decimal point.
This parameter does not apply to state sensors.ro Unsigned32 .1.3.6.1.4.1.13742.9.1.4.1.1.6 |
sensorMaximumThe largest possible value.
The value of this OID variable should be scaled by
sensorDecimalDigits. For example, if the value is 1 and
sensorDecimalDigits is 2, then actual value is 0.01.
This parameter does not apply to state sensors.ro Integer32 .1.3.6.1.4.1.13742.9.1.4.1.1.7 |
sensorMinimumThe smallest possible value.
The value of this OID variable should be scaled by
sensorDecimalDigits. For example, if the value is 1 and
sensorDecimalDigits is 2, then actual value is 0.01.
This parameter does not apply to state sensors.ro Integer32 .1.3.6.1.4.1.13742.9.1.4.1.1.8 |
sensorHysteresisThe hysteresis used for deassertions.
The value of this OID variable should be scaled by
sensorDecimalDigits. For example, if the value is 1 and
sensorDecimalDigits is 2, then actual value is 0.01.
This parameter does not apply to state sensors.rw Unsigned32 .1.3.6.1.4.1.13742.9.1.4.1.1.9 |
sensorLowerCriticalThresholdThe lower critical threshold.
The value of this OID variable should be scaled by
sensorDecimalDigits. For example, if the value is 1 and
sensorDecimalDigits is 2, then actual value is 0.01.
This parameter does not apply to state sensors.rw Integer32 .1.3.6.1.4.1.13742.9.1.4.1.1.10 |
sensorLowerWarningThresholdThe lower non-critical (warning) threshold.
The value of this OID variable should be scaled by
sensorDecimalDigits. For example, if the value is 1 and
sensorDecimalDigits is 2, then actual value is 0.01.
This parameter does not apply to state sensors.rw Integer32 .1.3.6.1.4.1.13742.9.1.4.1.1.11 |
sensorUpperCriticalThresholdThe upper critical threshold.
The value of this OID variable should be scaled by
sensorDecimalDigits. For example, if the value is 1 and
sensorDecimalDigits is 2, then actual value is 0.01.
This parameter does not apply to state sensors.rw Integer32 .1.3.6.1.4.1.13742.9.1.4.1.1.12 |
sensorUpperWarningThresholdThe upper non-critical (warning) threshold.
The value of this OID variable should be scaled by
sensorDecimalDigits. For example, if the value is 1 and
sensorDecimalDigits is 2, then actual value is 0.01.
This parameter does not apply to state sensors.rw Integer32 .1.3.6.1.4.1.13742.9.1.4.1.1.13 |
sensorEnabledThresholdsA bit string which indicates which thresholds are enabled.
This parameter does not apply to state sensors.rw Bits .1.3.6.1.4.1.13742.9.1.4.1.1.14 |
sensorThresholdMaximumThe largest possible threshold value.
The value of this OID variable should be scaled by
sensorDecimalDigits. For example, if the value is 1 and
sensorDecimalDigits is 2, then actual value is 0.01.
This parameter does not apply to state sensors.ro Integer32 .1.3.6.1.4.1.13742.9.1.4.1.1.15 |
sensorThresholdMinimumThe smallest possible threshold value.
The value of this OID variable should be scaled by
sensorDecimalDigits. For example, if the value is 1 and
sensorDecimalDigits is 2, then actual value is 0.01.
This parameter does not apply to state sensors.ro Integer32 .1.3.6.1.4.1.13742.9.1.4.1.1.16 |
sensorNameThe descriptive ID of the sensor (e.g. Fan Speed 1).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13742.9.1.4.1.1.17 |
measurements OBJECT IDENTIFIER .1.3.6.1.4.1.13742.9.2 |
sensorMeasurementsTableA list of external sensor entries. The number of
entries is given by the value of sensorCount
for the LHX. SEQUENCE OF SensorMeasurementsEntryStruct .1.3.6.1.4.1.13742.9.2.1 |
sensorMeasurementsEntryAn entry containing measurement objects for an external sensor. SensorMeasurementsEntryStruct .1.3.6.1.4.1.13742.9.2.1.1 |
measurementsSensorIsAvailableIs the sensor available?ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.13742.9.2.1.1.1 |
measurementsSensorStateThe sensor state.ro SensorStateEnumeration .1.3.6.1.4.1.13742.9.2.1.1.2 |
measurementsSensorValueThe sensor reading.
This parameter does not apply to state sensors.ro Integer32 .1.3.6.1.4.1.13742.9.2.1.1.3 |
measurementsSensorTimeStampThe sensor reading timestamp.ro Unsigned32 .1.3.6.1.4.1.13742.9.2.1.1.4 |
conformance OBJECT IDENTIFIER .1.3.6.1.4.1.13742.9.3 |
compliances OBJECT IDENTIFIER .1.3.6.1.4.1.13742.9.3.1 |
groups OBJECT IDENTIFIER .1.3.6.1.4.1.13742.9.3.2 |