Home/Catalog/PAIRGAIN-DSLAM-ALARM-SEVERITY-MIB

PAIRGAIN-DSLAM-ALARM-SEVERITY-MIB

AI MIB Summary

The PAIRGAIN-DSLAM-ALARM-SEVERITY-MIB configures and monitors alarm severity levels for PairGain DSLAM chassis components, including power supplies, fans, and HDSL/ADSL port states such as Loss of Frame (LOF), Loss of Signal (LOS), and Unavailable Seconds (UAS). It provides granular visibility into hardware and line-level fault conditions across ATUC/ATUR interfaces and specific card channels to facilitate rapid network fault isolation.

The MIB module defining objects for the alarm severity configuration and status management of a central DSLAM (Digital Subscriber Line Access Multiplexer), including from chassis power supply, fan status, to each channel/port related alarms in each HDSL/ADSL card inside the chassis. For HDSL alarm management: Please refer to Spec#157-1759-01 by Ken Huang for detail architecture model. For ADSL alarm management: Please refer to AdslLineMib(TR006) from adslForum for details architecture model. Naming Conventions: Atuc Atur ES Lof Los Lpr LOSW UAS
Main OID:
pgdsalsvMIB.1.3.6.1.4.1.927.1.9.3.1
47
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

47 total
Object Name
pgdsalsvMIBThe MIB module defining objects for the alarm severity configuration and status management of a central DSLAM (Digital Subscriber Line Access Multiplexer), including from chassis power supply, fan status, to each channel/port related alarms in each HDSL/ADSL card inside the chassis. For HDSL alarm management: Please refer to Spec#157-1759-01 by Ken Huang for detail architecture model. For ADSL alarm management: Please refer to AdslLineMib(TR006) from adslForum for details architecture model. Naming Conventions: Atuc Atur ES Lof Los Lpr LOSW UAS
MODULE-IDENTITY
.1.3.6.1.4.1.927.1.9.3.1
pgDSLAMHDSLSpanAlarmThresholdConfProfileIndexNextThis object contains an appropriate value to be used for pgDSLAMHDSLSpanAlarmThresholdConfProfileIndex when creating entries in the alarmThresholdConfTable. The value '0' indicates that no unassigned entries are available. To obtain the pgDSLAMHDSLSpanAlarmThresholdConfProfileIndexNext value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. After each retrieval, the agent should modify the value to the next unassigned index.ro
INTEGER
.1.3.6.1.4.1.927.1.9.3.1.7
pgDSLAMHDSLSpanAlarmThresholdConfProfileTableThe DSLAM HDSL Span Alarm Threshold Configuration Profile table.
SEQUENCE OF PgDSLAMHDSLSpanAlarmThresholdConfProfileEntry
.1.3.6.1.4.1.927.1.9.3.1.8
pgDSLAMHDSLSpanAlarmThresholdConfProfileEntryEntry in the DSLAM HDSL Span Alarm Threshold Configuration Profile table.
PgDSLAMHDSLSpanAlarmThresholdConfProfileEntry
.1.3.6.1.4.1.927.1.9.3.1.8.1
pgDSLAMHDSLSpanAlarmThresholdConfProfileIndexThis object is used by the line alarm Threshold configuration table in order to identify a row of this table
INTEGER
.1.3.6.1.4.1.927.1.9.3.1.8.1.1
pgDSLAMHDSLSpanMarginThresholdSets the HDSL Margin threshold value.rw
INTEGER
.1.3.6.1.4.1.927.1.9.3.1.8.1.2
pgDSLAMHDSLSpanESThresholdSets the HDSL Errored Seconds threshold value.rw
INTEGER
.1.3.6.1.4.1.927.1.9.3.1.8.1.3
pgDSLAMHDSLSpanUASThresholdSets the HDSL Unavailable Seconds threshold value.rw
INTEGER
.1.3.6.1.4.1.927.1.9.3.1.8.1.4
pgDSLAMHDSLSpanAlarmThresholdConfProfileRowStatusThis object is used to create a new row or modify or delete an existing row in this table.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.927.1.9.3.1.8.1.5
pgDSLAMHDSLSpanAlarmSeverityConfProfileIndexNextThis object contains an appropriate value to be used for pgDSLAMHDSLSpanAlarmSeverityConfProfileIndex when creating entries in the alarmSeverityConfTable. The value '0' indicates that no unassigned entries are available. To obtain the pgDSLAMHDSLSpanAlarmSeverityConfProfileIndexNext value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. After each retrieval, the agent should modify the value to the next unassigned index.ro
INTEGER
.1.3.6.1.4.1.927.1.9.3.1.9
pgDSLAMHDSLSpanAlarmSeverityConfProfileTableThe DSLAM HDSL Span Alarm Severity Configuration Profile table.
SEQUENCE OF PgDSLAMHDSLSpanAlarmSeverityConfProfileEntry
.1.3.6.1.4.1.927.1.9.3.1.10
pgDSLAMHDSLSpanAlarmSeverityConfProfileEntryEntry in the DSLAM HDSL Span Alarm Severity Configuration Profile table.
PgDSLAMHDSLSpanAlarmSeverityConfProfileEntry
.1.3.6.1.4.1.927.1.9.3.1.10.1
pgDSLAMHDSLSpanAlarmSeverityConfProfileIndexThis object is used by the line alarm severity configuration table in order to identify a row of this table
INTEGER
.1.3.6.1.4.1.927.1.9.3.1.10.1.1
pgDSLAMHDSLSpanLOSWAlarmSettingSets the severity for Loss of Sync Word alarm.rw
PgDSLAMAlarmSeverity
.1.3.6.1.4.1.927.1.9.3.1.10.1.2
pgDSLAMHDSLSpanMarginAlarmSettingSets the severity for Margin threshold exceeded alarm.rw
PgDSLAMAlarmSeverity
.1.3.6.1.4.1.927.1.9.3.1.10.1.3
pgDSLAMHDSLSpanESAlarmSettingSets the severity for Errored Seconds threshold exceeded alarm.rw
PgDSLAMAlarmSeverity
.1.3.6.1.4.1.927.1.9.3.1.10.1.4
pgDSLAMHDSLSpanUASAlarmSettingSets the severity for UAS threshold exceeded alarm.rw
PgDSLAMAlarmSeverity
.1.3.6.1.4.1.927.1.9.3.1.10.1.5
pgDSLAMHDSLSpanAlarmSeverityConfProfileRowStatusThis object is used to create a new row or modify or delete an existing row in this table.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.927.1.9.3.1.10.1.6
pgDSLAMChassisAlarmSeverity
OBJECT IDENTIFIER
.1.3.6.1.4.1.927.1.9.3.2
pgDSLAMChassisPsAlarmSeverityThe Chassis Power failure Alarm Severity Setting.rw
PgDSLAMAlarmSeverity
.1.3.6.1.4.1.927.1.9.3.2.1
pgDSLAMChassisFanAlarmSeverityThe Chassis Fan failure Alarm Severity Setting.rw
PgDSLAMAlarmSeverity
.1.3.6.1.4.1.927.1.9.3.2.2
pgDSLAMChassisConfigChangeAlarmSeverityThe Chassis Config change Alarm Severity Setting.rw
PgDSLAMAlarmSeverity
.1.3.6.1.4.1.927.1.9.3.2.3
pgDSLAMChassisTempAlarmSeverityThe Chassis Temperature exceed threshold Alarm Severity Setting.rw
PgDSLAMAlarmSeverity
.1.3.6.1.4.1.927.1.9.3.2.4
pgDSLAMADSLAtucAlarmTableThe DSLAM ADSL ATU-C Alarm indication table.
SEQUENCE OF PgDSLAMADSLAtucAlarmEntry
.1.3.6.1.4.1.927.1.9.4.1
pgDSLAMADSLAtucAlarmEntryEntry in the DSLAM ADSL ATU-C Alarm indication table.
PgDSLAMADSLAtucAlarmEntry
.1.3.6.1.4.1.927.1.9.4.1.1
pgDSLAMADSLAtucLofAlarmADSL loss of framing alarm on ATU-Cro
PgDSLAMAlarmStatus
.1.3.6.1.4.1.927.1.9.4.1.1.1
pgDSLAMADSLAtucLosAlarmADSL loss of signal alarm on ATU-Cro
PgDSLAMAlarmStatus
.1.3.6.1.4.1.927.1.9.4.1.1.2
pgDSLAMADSLAtucLprAlarmADSL loss of power alarm on ATU-Cro
PgDSLAMAlarmStatus
.1.3.6.1.4.1.927.1.9.4.1.1.3
pgDSLAMADSLAtucESAlarmADSL Errored Second threshold exceeded alarm on ATU-Cro
PgDSLAMAlarmStatus
.1.3.6.1.4.1.927.1.9.4.1.1.4
pgDSLAMADSLAtucRateChangeAlarmADSL Rate Changed alarm on ATU-Cro
PgDSLAMAlarmStatus
.1.3.6.1.4.1.927.1.9.4.1.1.5
pgDSLAMADSLAtucInitFailureAlarmADSL initialization failed alarm on ATU-Cro
PgDSLAMAlarmStatus
.1.3.6.1.4.1.927.1.9.4.1.1.6
pgDSLAMADSLAturAlarmTableThe DSLAM ADSL ATU-R Alarm indication table.
SEQUENCE OF PgDSLAMADSLAturAlarmEntry
.1.3.6.1.4.1.927.1.9.4.2
pgDSLAMADSLAturAlarmEntryEntry in the DSLAM ADSL ATU-R Alarm indication table.
PgDSLAMADSLAturAlarmEntry
.1.3.6.1.4.1.927.1.9.4.2.1
pgDSLAMADSLAturLofAlarmADSL loss of framing alarm on ATU-Rro
PgDSLAMAlarmStatus
.1.3.6.1.4.1.927.1.9.4.2.1.1
pgDSLAMADSLAturLosAlarmADSL loss of signal alarm on ATU-Rro
PgDSLAMAlarmStatus
.1.3.6.1.4.1.927.1.9.4.2.1.2
pgDSLAMADSLAturLprAlarmADSL loss of power alarm on ATU-Rro
PgDSLAMAlarmStatus
.1.3.6.1.4.1.927.1.9.4.2.1.3
pgDSLAMADSLAturESAlarmADSL Errored Second threshold exceeded alarm on ATU-Rro
PgDSLAMAlarmStatus
.1.3.6.1.4.1.927.1.9.4.2.1.4
pgDSLAMADSLAturRateChangeAlarmADSL Rate Changed alarm on ATU-Rro
PgDSLAMAlarmStatus
.1.3.6.1.4.1.927.1.9.4.2.1.5
pgDSLAMADSLAturInitFailureAlarmADSL initialization failed alarm on ATU-Rro
PgDSLAMAlarmStatus
.1.3.6.1.4.1.927.1.9.4.2.1.6
pgDSLAMChassisAlarmTableThe DSLAM Chassis Alarm indication table.
SEQUENCE OF PgDSLAMChassisAlarmEntry
.1.3.6.1.4.1.927.1.9.4.3
pgDSLAMChassisAlarmEntryEntry in the DSLAM Chassis Alarm indication table.
PgDSLAMChassisAlarmEntry
.1.3.6.1.4.1.927.1.9.4.3.1
pgDSLAMPSFailureAlarmchassis power supply failure alarmro
PgDSLAMAlarmStatus
.1.3.6.1.4.1.927.1.9.4.3.1.1
pgDSLAMFanFailureAlarmchassis fan failure alarmro
PgDSLAMAlarmStatus
.1.3.6.1.4.1.927.1.9.4.3.1.2
pgDSLAMConfigChangeAlarmchassis config changed alarmro
PgDSLAMAlarmStatus
.1.3.6.1.4.1.927.1.9.4.3.1.3
pgDSLAMTempExceedThreshAlarmchassis temperature exceeded thresholdro
PgDSLAMAlarmStatus
.1.3.6.1.4.1.927.1.9.4.3.1.4
pgDSLAMLineCardDownAlarmthe line card in the chassis is downro
PgDSLAMAlarmStatus
.1.3.6.1.4.1.927.1.9.4.3.1.5
pgDSLAMCellBusDownAlarmthe cell bus in the chassis is downro
PgDSLAMAlarmStatus
.1.3.6.1.4.1.927.1.9.4.3.1.6
PAIRGAIN-DSLAM-ALARM-SEVERITY-MIB - SNMP MIB Reference | MIBs Explorer