PAIRGAIN-ATMTEST-MIB
AI MIB Summary
The PAIRGAIN-ATMTEST-MIB enables the monitoring and diagnostic testing of ATM Virtual Channel Connections (VCCs) on PairGain telecommunications hardware, specifically tracking VCC status, error counters, and loopback test states to validate circuit integrity.
A MIB module for testing ATM Virtual Channel connections.
Main OID:
pgATMTestMIB.1.3.6.1.4.1.927.1.9.9
29
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
29 total| Object Name |
|---|
pgATMTestMIBA MIB module for testing ATM Virtual Channel connections. MODULE-IDENTITY .1.3.6.1.4.1.927.1.9.9 |
pgATMTestMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.927.1.9.9.1 |
pgoamLoopbackAddressSpecifies the local ATM devices ATM address. Other ATM devices use the ATM address to identify this local ATM device as the device that is being requested to loopback the OAM Loopback cell.rw OCTET STRING .1.3.6.1.4.1.927.1.9.9.1.1 |
pgoamLoopbackTableA table of OAM loopback request entries. SEQUENCE OF PgoamLoopbackEntry .1.3.6.1.4.1.927.1.9.9.1.2 |
pgoamLoopbackEntryA OAM loopback request entry. Each entry in the table is uniquely identified by ifIndex, VPI and VCI. To start a test, use NMS to create the associated instance of the row status and row owner objects. Also use NMS to modify the default values for the other configuration objects if the defaults are not appropriate. Once you have used NMS to create the appropriate instance of all of the configuration objects, either by an explicit SNMP set request or by default, use NMS to set the row status to active to initiate the request. Note that this entire procedure can be initiated using a single set request that specifies a row status of createAndGo as well as the valid values for the non-defaulted configuration objects. once the OAM test sequence has been activated, it can be aborted by setting RowStatus from active to notInService. Once the test sequence completes, the NMS should retrieve the values of the status objects of interest and then delete the entry. To prevent old entries from clogging the table, whenever a new OAM loopback test is requested on a VPI VCI, the old VPI VCI entry is deleted and the entries marked expired are also deleted. PgoamLoopbackEntry .1.3.6.1.4.1.927.1.9.9.1.2.1 |
pgoamLoopbackIfIndexThe interface of the connection on which F5 OAM loopbacks are to be sent. Once an instance of this object is created, its value can not be changed. The value specified for this object must equate to a value of ifIndex in the ifTable.ro Integer32 .1.3.6.1.4.1.927.1.9.9.1.2.1.1 |
pgoamLoopbackVpiThe VPI of the connection on which F4/F5 OAM loopbacks are to be sent.ro INTEGER .1.3.6.1.4.1.927.1.9.9.1.2.1.2 |
pgoamLoopbackVciThe VCI of the connection on which OAM loopback cells are to be sent.ro INTEGER .1.3.6.1.4.1.927.1.9.9.1.2.1.3 |
pgoamLoopbackTypeSpecifies the type of OAM loopback to be performed: segment loopbacks (1) or end to end loopbacks (2). The default is segment loopbacks (1).rw Enumeration .1.3.6.1.4.1.927.1.9.9.1.2.1.5 |
pgoamLoopbackLocationSpecifies the target ATM devices ATM address to be placed in the 'Loopback Location ID' field of the OAM loopback cell. It is used only when pgoamLoopbackType is set to segment (1).rw OCTET STRING .1.3.6.1.4.1.927.1.9.9.1.2.1.6 |
pgoamLoopbackCountSpecifies the number of OAM loopback cells (1 to 10) to send to the target in this test sequence. The default is 1 cell.rw INTEGER .1.3.6.1.4.1.927.1.9.9.1.2.1.7 |
pgoamLoopbackTimeoutSpecifies the amount of time (5 to 15 seconds) to wait for a response from one transmitted OAM loopback cell before declaring the OAM loopback cells as 'dropped.' The default is 5 seconds.rw INTEGER .1.3.6.1.4.1.927.1.9.9.1.2.1.8 |
pgoamLoopbackDelaySpecifies the minimum amount of time (5 to 15 seconds) to wait before sending the next OAM loopback cell in a test sequence after receiving a response or declaring a timeout for a previous OAM cell. The actual delay may be greater due to internal task scheduling. The default is 5 seconds.rw INTEGER .1.3.6.1.4.1.927.1.9.9.1.2.1.9 |
pgoamLoopbackTrapOnCompletionSpecifies whether an oamLoopbackCompletion trap should be issued on completion of the test sequence of OAM loopback cells. If such a trap is desired, it is the responsibility of NMS to ensure that the SNMP administrative model is configured to allow the trap to be delivered.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.927.1.9.9.1.2.1.10 |
pgoamLoopbackSentCellsThe number of OAM loopback cells that have been sent to the target in this test sequence.ro Counter32 .1.3.6.1.4.1.927.1.9.9.1.2.1.11 |
pgoamLoopbackReceivedCellsThe number of OAM loopback cells that have been received from the target in this test sequence.ro Counter32 .1.3.6.1.4.1.927.1.9.9.1.2.1.12 |
pgoamLoopbackErroredCellsThe number of OAM Loopback cells that have been received with CRC errors.ro Counter32 .1.3.6.1.4.1.927.1.9.9.1.2.1.13 |
pgoamLoopbackStatusSet to null (1) when there is no status to report. Set to inProgress (2) as soon as the first OAM loopback cell is sent. Set to completed (3) when all the OAM loopback cells in this test sequence have been responded to or timed out. Set to aborted (4) when the OAM loopback test is aborted by setting pgoamLoopBackEntryStatus to notInService. Set to failed (5) when the OAM loopback cells in this test sequence were timed out, not sent, or not returned. Set to expired (6) 5 minutes after the operation is aborted , completed or failed. When the Status is Expired, the next set operation will automatically delete this entry.ro Enumeration .1.3.6.1.4.1.927.1.9.9.1.2.1.14 |
pgoamLoopbackEntryOwnerThe NMS entity that configured this entry.rw OwnerString (IF-MIB) .1.3.6.1.4.1.927.1.9.9.1.2.1.15 |
pgoamLoopbackEntryStatusThe status of this table entry. Once the entry status is set to active, the associate entry cannot be deleted until the test sequence completes (oamLoopbackStatus is set to completed). But it can be set to notInService to abort the ongoing loopback Testrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.927.1.9.9.1.2.1.16 |
pgoamLoopbackFlowTypeThis object identifies if the cells are of F4/F5 type when value of this object is set to oamF4, the value of pgoamloopbackVci has to be set to 3 or 4, else the agent should return errorrw Enumeration .1.3.6.1.4.1.927.1.9.9.1.2.1.17 |
pgATMTestMIBTrapPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.927.1.9.9.2 |
pgoamLoopbackMIBTraps OBJECT IDENTIFIER .1.3.6.1.4.1.927.1.9.9.2.0 |
pgoamLoopbackCompletionTrapA oamLoopbackCompleted trap is sent at the completion of a test sequence of OAM loopback cells if such a trap was requested when the test sequence was initiated. NOTIFICATION-TYPE .1.3.6.1.4.1.927.1.9.9.2.0.1 |
pgATMTestMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.927.1.9.9.3 |
pgATMTestMIBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.927.1.9.9.3.1 |
pgATMTestMIBComplianceThe compliance statement for PairGain ATM Test MIB. Unknown .1.3.6.1.4.1.927.1.9.9.3.1.1 |
pgATMTestMIBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.927.1.9.9.3.2 |
pgATMTestMIBGroupA collection of objects that invoke the sending of OAM loopback cells. Unknown .1.3.6.1.4.1.927.1.9.9.3.2.1 |