Nortel-MsCarrier-MscPassport-BusMIB
AI MIB Summary
Standard SNMP MIB module defining data structures for Nortel-MsCarrier-MscPassport-BusMIB.
136
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
136 total| Object Name |
|---|
mscShelfCardBusTap OBJECT IDENTIFIER .1.3.6.1.4.1.562.36.2.1.13.2.2 |
mscShelfCardBusTapRowStatusTableThis entry controls the addition and deletion of
mscShelfCardBusTap components. SEQUENCE OF MscShelfCardBusTapRowStatusEntry .1.3.6.1.4.1.562.36.2.1.13.2.2.1 |
mscShelfCardBusTapRowStatusEntryA single entry in the table represents a single
mscShelfCardBusTap component. MscShelfCardBusTapRowStatusEntry .1.3.6.1.4.1.562.36.2.1.13.2.2.1.1 |
mscShelfCardBusTapRowStatusThis variable is used as the basis for SNMP naming of
mscShelfCardBusTap components.
These components cannot be added nor deleted.ro RowStatus (SNMPv2-TC) .1.3.6.1.4.1.562.36.2.1.13.2.2.1.1.1 |
mscShelfCardBusTapComponentNameThis variable provides the component's string name for
use with the ASCII Console Interfacero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.562.36.2.1.13.2.2.1.1.2 |
mscShelfCardBusTapStorageTypeThis variable represents the storage type value for the
mscShelfCardBusTap tables.ro StorageType (SNMPv2-TC) .1.3.6.1.4.1.562.36.2.1.13.2.2.1.1.4 |
mscShelfCardBusTapIndexThis variable represents the index for the mscShelfCardBusTap tables. Enumeration .1.3.6.1.4.1.562.36.2.1.13.2.2.1.1.10 |
mscShelfCardBusTapStateTableThis group contains the three OSI State attributes and the six OSI
Status attributes. The descriptions generically indicate what each
attribute implies about the component. Note that not all the values
and state combinations described here are supported by every
component which uses this group. For component-specific
information and the valid state combinations, refer to NTP 241-
7001-150, Passport Operations and Maintenance Guide. SEQUENCE OF MscShelfCardBusTapStateEntry .1.3.6.1.4.1.562.36.2.1.13.2.2.10 |
mscShelfCardBusTapStateEntryAn entry in the mscShelfCardBusTapStateTable. MscShelfCardBusTapStateEntry .1.3.6.1.4.1.562.36.2.1.13.2.2.10.1 |
mscShelfCardBusTapAdminStateThis attribute indicates the OSI Administrative State of the
component.
The value locked indicates that the component is administratively
prohibited from providing services for its users. A Lock or Lock -
force command has been previously issued for this component.
When the value is locked, the value of usageState must be idle.
The value shuttingDown indicates that the component is
administratively permitted to provide service to its existing users
only. A Lock command was issued against the component and it is
in the process of shutting down.
The value unlocked indicates that the component is administratively
permitted to provide services for its users. To enter this state, issue
an Unlock command to this component.
The OSI Status attributes, if supported by the component, may
provide more details, qualifying the state of the component.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.2.2.10.1.1 |
mscShelfCardBusTapOperationalStateThis attribute indicates the OSI Operational State of the component.
The value enabled indicates that the component is available for
operation. Note that if adminState is locked, it would still not be
providing service.
The value disabled indicates that the component is not available for
operation. For example, something is wrong with the component
itself, or with another component on which this one depends. If the
value is disabled, the usageState must be idle.
The OSI Status attributes, if supported by the component, may
provide more details, qualifying the state of the component.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.2.2.10.1.2 |
mscShelfCardBusTapUsageStateThis attribute indicates the OSI Usage State of the component.
The value idle indicates that the component is not currently in use.
The value active indicates that the component is in use and has
spare capacity to provide for additional users.
The value busy indicates that the component is in use and has no
spare operating capacity for additional users at this time.
The OSI Status attributes, if supported by the component, may
provide more details, qualifying the state of the component.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.2.2.10.1.3 |
mscShelfCardBusTapAvailabilityStatusIf supported by the component, this attribute indicates the OSI
Availability status of the component. Note that, even though it is
defined as a multi-valued set, at most one value is shown to the user.
When no values are in the set, this indicates that either the attribute
is not supported or that none of the status conditions described
below are present.
The value inTest indicates that the resource is undergoing a test
procedure. If adminState is locked or shuttingDown, the normal
users are precluded from using the resource and controlStatus is
reservedForTest. Tests that do not exclude additional users can be
present in any operational or administrative state but the
reservedForTest condition should not be present.
The value failed indicates that the component has an internal fault
that prevents it from operating. The operationalState is disabled.
The value dependency indicates that the component cannot operate
because some other resource on which it depends is unavailable.
The operationalState is disabled.
The value powerOff indicates the resource requires power to be
applied and it is not powered on. The operationalState is disabled.
The value offLine indicates the resource requires a routine
operation (either manual, automatic, or both) to be performed to
place it on-line and make it available for use. The operationalState
is disabled.
The value offDuty indicates the resource is inactive in accordance
with a predetermined time schedule. In the absence of other
disabling conditions, the operationalState is enabled or disabled.
The value degraded indicates the service provided by the
component is degraded in some way, such as in speed or operating
capacity. However, the resource remains available for service. The
operationalState is enabled.
The value notInstalled indicates the resource is not present. The
operationalState is disabled.
The value logFull is not used.
Description of bits:
inTest(0)
failed(1)
powerOff(2)
offLine(3)
offDuty(4)
dependency(5)
degraded(6)
notInstalled(7)
logFull(8)ro OCTET STRING .1.3.6.1.4.1.562.36.2.1.13.2.2.10.1.4 |
mscShelfCardBusTapProceduralStatusIf supported by the component, this attribute indicates the OSI
Procedural status of the component. Note that, even though it is
defined as a multi-valued set, at most one value is shown to the user.
When no values are in the set, this indicates that either the attribute
is not supported or that none of the status conditions described
below are present.
The value initializationRequired indicates (for a resource which
doesn't initialize autonomously) that initialization is required before
it can perform its normal functions, and this procedure has not been
initiated. The operationalState is disabled.
The value notInitialized indicates (for a resource which does
initialize autonomously) that initialization is required before it can
perform its normal functions, and this procedure has not been
initiated. The operationalState may be enabled or disabled.
The value initializing indicates that initialization has been initiated
but is not yet complete. The operationalState may be enabled or
disabled.
The value reporting indicates the resource has completed some
processing operation and is notifying the results. The
operationalState is enabled.
The value terminating indicates the component is in a termination
phase. If the resource doesn't reinitialize autonomously,
operationalState is disabled; otherwise it is enabled or disabled.
Description of bits:
initializationRequired(0)
notInitialized(1)
initializing(2)
reporting(3)
terminating(4)ro OCTET STRING .1.3.6.1.4.1.562.36.2.1.13.2.2.10.1.5 |
mscShelfCardBusTapControlStatusIf supported by the component, this attribute indicates the OSI
Control status of the component. Note that, even though it is defined
as a multi-valued set, at most one value is shown to the user.
When no values are in the set, this indicates that either the attribute
is not supported or that none of the status conditions described
below are present.
The value subjectToTest indicates the resource is available but tests
may be conducted simultaneously at unpredictable times, which
may cause it to exhibit unusual characteristics.
The value partOfServicesLocked indicates that part of the service is
restricted from users of a resource. The adminState is unlocked.
The value reservedForTest indicates that the component is
administratively unavailable because it is undergoing a test
procedure. The adminState is locked.
The value suspended indicates that the service has been
administratively suspended.
Description of bits:
subjectToTest(0)
partOfServicesLocked(1)
reservedForTest(2)
suspended(3)ro OCTET STRING .1.3.6.1.4.1.562.36.2.1.13.2.2.10.1.6 |
mscShelfCardBusTapAlarmStatusIf supported by the component, this attribute indicates the OSI
Alarm status of the component. Note that, even though it is defined
as a multi-valued set, at most one value is shown to the user.
When no values are in the set, this indicates that either the attribute
is not supported or that none of the status conditions described
below are present.
The value underRepair indicates the component is currently being
repaired. The operationalState is enabled or disabled.
The value critical indicates one or more critical alarms are
outstanding against the component. Other, less severe, alarms may
also be outstanding. The operationalState is enabled or disabled.
The value major indicates one or more major alarms are
outstanding against the component. Other, less severe, alarms may
also be outstanding. The operationalState is enabled or disabled.
The value minor indicates one or more minor alarms are
outstanding against the component. Other, less severe, alarms may
also be outstanding. The operationalState is enabled or disabled.
The value alarmOutstanding generically indicates that an alarm of
some severity is outstanding against the component.
Description of bits:
underRepair(0)
critical(1)
major(2)
minor(3)
alarmOutstanding(4)ro OCTET STRING .1.3.6.1.4.1.562.36.2.1.13.2.2.10.1.7 |
mscShelfCardBusTapStandbyStatusIf supported by the component, this attribute indicates the OSI
Standby status of the component.
The value notSet indicates that either the attribute is not supported
or that none of the status conditions described below are present.
Note that this is a non-standard value, used because the original
specification indicated this attribute was set-valued and thus, did not
provide a value to indicate that none of the other three are
applicable.
The value hotStandby indicates that the resource is not providing
service but will be immediately able to take over the role of the
resource to be backed up, without initialization activity, and
containing the same information as the resource to be backed up.
The value coldStandby indicates the resource is a backup for
another resource but will not be immediately able to take over the
role of the backed up resource and will require some initialization
activity.
The value providingService indicates that this component, as a
backup resource, is currently backing up another resource.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.2.2.10.1.8 |
mscShelfCardBusTapUnknownStatusThis attribute indicates the OSI Unknown status of the component.
The value false indicates that all of the other OSI State and Status
attribute values can be considered accurate.
The value true indicates that the actual state of the component is not
known for sure.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.2.2.10.1.9 |
mscShelfCardBusTapOperTableThis attribute group contains operational attributes of a bus tap. This
information outlines what the bus tap is doing and why it is doing it,
and is primarily intended for use in diagnosing the cause of a bus-
related problem reported by the module. SEQUENCE OF MscShelfCardBusTapOperEntry .1.3.6.1.4.1.562.36.2.1.13.2.2.11 |
mscShelfCardBusTapOperEntryAn entry in the mscShelfCardBusTapOperTable. MscShelfCardBusTapOperEntry .1.3.6.1.4.1.562.36.2.1.13.2.2.11.1 |
mscShelfCardBusTapFailuresInEffectThis attribute records the hardware problems that prevent the bus
tap from using the associated bus. It may contain any combination
of the following values.
selfTest: the bus tap has failed its self-test
clockSignal: the bus tap is not receiving clock signals from the bus
parityError: the bus tap has detected too many parity errors on the
bus
Description of bits:
selfTest(0)
clockSignal(1)
parityError(2)ro OCTET STRING .1.3.6.1.4.1.562.36.2.1.13.2.2.11.1.1 |
mscShelfCardBusTapDependenciesInEffectThis attribute records the non-hardware problems that prevent the
bus tap from using the associated bus. It may contain any
combination of the following values.
busLocked: the bus is locked
busDisabled: the bus is disabled
Description of bits:
busLocked(0)
busDisabled(1)ro OCTET STRING .1.3.6.1.4.1.562.36.2.1.13.2.2.11.1.2 |
mscShelfCardBusTapCardsAvailableThis attribute records the slot numbers of the cards that the bus tap
considers available on the busthat is, the cards that have an
operational bus tap connected to the bus. The value of this attribute
is determined automatically by the bus tap by monitoring signals
generated by each bus tap on the bus; it cannot be changed by the
operator. Normally, every card in the module signals its availability
on both buses; if a card does not signal its availability on a bus this
indicates that the card is not present or that its bus tap has failed. By
examining this attribute for both of a card's BusTap components, it
is possible to determine which cards are present in the module and
which buses each can use.
Note: If failuresInEffect contains either selfTest or clockSignal the
bus tap is unable to monitor the availability of the bus taps on the
bus; cardsAvailable will indicate that no bus taps are available on
the bus.
Description of bits:
n0(0)
n1(1)
n2(2)
n3(3)
n4(4)
n5(5)
n6(6)
n7(7)
n8(8)
n9(9)
n10(10)
n11(11)
n12(12)
n13(13)
n14(14)
n15(15)ro OCTET STRING .1.3.6.1.4.1.562.36.2.1.13.2.2.11.1.3 |
mscShelfCardBusTapCardsTxToThis attribute records the slot numbers of the cards which the bus
tap is currently configured to transmit cells to. This configuration is
managed automatically, and cannot be changed by the operator. By
examining this attribute for both of a card's BusTap components, it
is possible to determine which bus (if any) the card uses when it
needs to transmits cells to a specific card in the module.
Description of bits:
n0(0)
n1(1)
n2(2)
n3(3)
n4(4)
n5(5)
n6(6)
n7(7)
n8(8)
n9(9)
n10(10)
n11(11)
n12(12)
n13(13)
n14(14)
n15(15)ro OCTET STRING .1.3.6.1.4.1.562.36.2.1.13.2.2.11.1.4 |
mscShelfCardBusTapErrorsTableThis attribute group records errors that the bus tap has detected
since the card was last rebooted. This information is intended for
use in detecting and diagnosing bus-related problems within a
module. SEQUENCE OF MscShelfCardBusTapErrorsEntry .1.3.6.1.4.1.562.36.2.1.13.2.2.12 |
mscShelfCardBusTapErrorsEntryAn entry in the mscShelfCardBusTapErrorsTable. MscShelfCardBusTapErrorsEntry .1.3.6.1.4.1.562.36.2.1.13.2.2.12.1 |
mscShelfCardBusTapSelfTestErrorCodeThis attribute records the error code generated by the most recent
self-test of the bus tap. The value zero indicates that the self-test
was successful. A non-zero value indicates that the self-test failed,
and is used by the service technician when a defective card is
returned for repair.ro Unsigned32 .1.3.6.1.4.1.562.36.2.1.13.2.2.12.1.1 |
mscShelfCardBusTapClockErrorsThis attribute records the number of times that the bus tap has
detected a loss of the fundamental clock signal used by the bus.
Each occurrence may result in the loss of one or more cells or
frames. This type of event may occur during normal operation of
the module, for example when switching from one of the bus's
clock sources to the other; it may also be caused by a hardware
fault.
The attribute's value wraps around to zero when it exceeds the
maximum permitted value.ro Unsigned32 .1.3.6.1.4.1.562.36.2.1.13.2.2.12.1.2 |
mscShelfCardBusTapEndOfCellErrorsThis attribute records the number of times that the bus tap has
detected a loss of the end-of-cell timing signal used by the bus.
Each occurrence may result in the loss of one or more cells or
frames. This type of event may occur during normal operation of
the module, for example switching the bus's clock source from one
card to another; it may also be caused by a hardware fault.
The attribute's value wraps around to zero when it exceeds the
maximum permitted value.ro Unsigned32 .1.3.6.1.4.1.562.36.2.1.13.2.2.12.1.3 |
mscShelfCardBusTapParityErrorsThis attribute records the number of times that the bus tap has
detected a cell with invalid parity on the bus. Each occurrence may
result in the loss of one or more cells or frames. This type of event
may occur during normal operation of the module, for example
when a card is inserted, removed, or reboots; it may also be caused
by a hardware fault.
The attribute's value wraps around to zero when it exceeds the
maximum permitted value.ro Unsigned32 .1.3.6.1.4.1.562.36.2.1.13.2.2.12.1.4 |
mscShelfCardBusTapFrmCongestionErrorsThis attribute records the number of times that the bus tap was
unable to receive a frame from the bus because all of its bus receive
channels were in use. Each occurrence results in the loss of the
frame. This type of event may occur during normal operation of the
module, for example when the module is operating in single bus
mode; it may also be caused by a hardware fault.
The attribute's value wraps around to zero when it exceeds the
maximum permitted value.ro Unsigned32 .1.3.6.1.4.1.562.36.2.1.13.2.2.12.1.5 |
mscShelfCardBusTapFrmCollisionErrorsThis attribute records the number of times that the bus tap was
unable to receive a frame from the bus because it did not receive the
last cell of the frame before the first cell of the following frame
from the same source. Each occurrence results in the loss of both
frames. This type of event may occur during normal operation of
the module, for example when a card reboots; it may also be caused
by a hardware fault.
The attribute's value wraps around to zero when it exceeds the
maximum permitted value.ro Unsigned32 .1.3.6.1.4.1.562.36.2.1.13.2.2.12.1.6 |
mscShelfCardBusTapFrmTimeoutErrorsThis attribute records the number of times that the bus tap was
unable to receive a frame from the bus because the delay between
two successive cells in that frame exceeded the maximum allowable
duration. Each occurrence results in the loss of the frame. This type
of event may occur during normal operation of the module, for
example when the module changes bus mode; it may also be caused
by a hardware fault.
The attribute's value wraps around to zero when it exceeds the
maximum permitted value.ro Unsigned32 .1.3.6.1.4.1.562.36.2.1.13.2.2.12.1.7 |
mscShelfCardBusTapFrmDeliveryErrorsThis attribute records the number of times that the bus tap was
unable to receive a frame from the bus because it was destined for a
bus transmit queue; that is, the frame would have been immediately
retransmitted over a bus. Each occurrence results in the loss of the
frame. This type of event should never occur during normal
operation of the module and indicates the occurrence of a hardware
or software fault.
The attribute's value wraps around to zero when it exceeds the
maximum permitted value.ro Unsigned32 .1.3.6.1.4.1.562.36.2.1.13.2.2.12.1.8 |
mscShelfCardBusTapFrmSizeErrorsThis attribute records the number of times that the bus tap was
unable to receive a frame from the bus because it required more
than 255 blocks of shared memory. Each occurrence results in the
loss of the frame. This type of event should never occur during
normal operation of the module and indicates improper
configuration of the card or the occurrence of a hardware or
software fault.
The attribute's value wraps around to zero when it exceeds the
maximum permitted value.ro Unsigned32 .1.3.6.1.4.1.562.36.2.1.13.2.2.12.1.9 |
mscShelfBus OBJECT IDENTIFIER .1.3.6.1.4.1.562.36.2.1.13.3 |
mscShelfBusRowStatusTableThis entry controls the addition and deletion of
mscShelfBus components. SEQUENCE OF MscShelfBusRowStatusEntry .1.3.6.1.4.1.562.36.2.1.13.3.1 |
mscShelfBusRowStatusEntryA single entry in the table represents a single
mscShelfBus component. MscShelfBusRowStatusEntry .1.3.6.1.4.1.562.36.2.1.13.3.1.1 |
mscShelfBusRowStatusThis variable is used as the basis for SNMP naming of
mscShelfBus components.
These components cannot be added nor deleted.ro RowStatus (SNMPv2-TC) .1.3.6.1.4.1.562.36.2.1.13.3.1.1.1 |
mscShelfBusComponentNameThis variable provides the component's string name for
use with the ASCII Console Interfacero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.562.36.2.1.13.3.1.1.2 |
mscShelfBusStorageTypeThis variable represents the storage type value for the
mscShelfBus tables.ro StorageType (SNMPv2-TC) .1.3.6.1.4.1.562.36.2.1.13.3.1.1.4 |
mscShelfBusIndexThis variable represents the index for the mscShelfBus tables. Enumeration .1.3.6.1.4.1.562.36.2.1.13.3.1.1.10 |
mscShelfBusTest OBJECT IDENTIFIER .1.3.6.1.4.1.562.36.2.1.13.3.2 |
mscShelfBusTestRowStatusTableThis entry controls the addition and deletion of
mscShelfBusTest components. SEQUENCE OF MscShelfBusTestRowStatusEntry .1.3.6.1.4.1.562.36.2.1.13.3.2.1 |
mscShelfBusTestRowStatusEntryA single entry in the table represents a single
mscShelfBusTest component. MscShelfBusTestRowStatusEntry .1.3.6.1.4.1.562.36.2.1.13.3.2.1.1 |
mscShelfBusTestRowStatusThis variable is used as the basis for SNMP naming of
mscShelfBusTest components.
These components cannot be added nor deleted.ro RowStatus (SNMPv2-TC) .1.3.6.1.4.1.562.36.2.1.13.3.2.1.1.1 |
mscShelfBusTestComponentNameThis variable provides the component's string name for
use with the ASCII Console Interfacero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.562.36.2.1.13.3.2.1.1.2 |
mscShelfBusTestStorageTypeThis variable represents the storage type value for the
mscShelfBusTest tables.ro StorageType (SNMPv2-TC) .1.3.6.1.4.1.562.36.2.1.13.3.2.1.1.4 |
mscShelfBusTestIndexThis variable represents the index for the mscShelfBusTest tables. NonReplicated .1.3.6.1.4.1.562.36.2.1.13.3.2.1.1.10 |
mscShelfBusTestStateTableThis group contains the three OSI State attributes. The descriptions
generically indicate what each state attribute implies about the
component. Note that not all the values and state combinations
described here are supported by every component which uses this
group. For component-specific information and the valid state
combinations, refer to NTP 241-7001-150, Passport Operations and
Maintenance Guide. SEQUENCE OF MscShelfBusTestStateEntry .1.3.6.1.4.1.562.36.2.1.13.3.2.10 |
mscShelfBusTestStateEntryAn entry in the mscShelfBusTestStateTable. MscShelfBusTestStateEntry .1.3.6.1.4.1.562.36.2.1.13.3.2.10.1 |
mscShelfBusTestAdminStateThis attribute indicates the OSI Administrative State of the
component.
The value locked indicates that the component is administratively
prohibited from providing services for its users. A Lock or Lock -
force command has been previously issued for this component.
When the value is locked, the value of usageState must be idle.
The value shuttingDown indicates that the component is
administratively permitted to provide service to its existing users
only. A Lock command was issued against the component and it is
in the process of shutting down.
The value unlocked indicates that the component is administratively
permitted to provide services for its users. To enter this state, issue
an Unlock command to this component.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.3.2.10.1.1 |
mscShelfBusTestOperationalStateThis attribute indicates the OSI Operational State of the component.
The value enabled indicates that the component is available for
operation. Note that if adminState is locked, it would still not be
providing service.
The value disabled indicates that the component is not available for
operation. For example, something is wrong with the component
itself, or with another component on which this one depends. If the
value is disabled, the usageState must be idle.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.3.2.10.1.2 |
mscShelfBusTestUsageStateThis attribute indicates the OSI Usage State of the component.
The value idle indicates that the component is not currently in use.
The value active indicates that the component is in use and has
spare capacity to provide for additional users.
The value busy indicates that the component is in use and has no
spare operating capacity for additional users at this time.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.3.2.10.1.3 |
mscShelfBusTestSetupTableThis attribute group contains the attributes that govern the operation
of a bus test. These attributes cannot be changed while the bus test
is running. SEQUENCE OF MscShelfBusTestSetupEntry .1.3.6.1.4.1.562.36.2.1.13.3.2.11 |
mscShelfBusTestSetupEntryAn entry in the mscShelfBusTestSetupTable. MscShelfBusTestSetupEntry .1.3.6.1.4.1.562.36.2.1.13.3.2.11.1 |
mscShelfBusTestDurationThis attribute specifies the maximum length of time that the bus test
is allowed to run. The value is expressed in minutes. The maximum
allowed value permits the bus test to be run for up to 30 days.rw Unsigned32 .1.3.6.1.4.1.562.36.2.1.13.3.2.11.1.1 |
mscShelfBusTestResultsTableThis attribute group contains the results of the bus test that is
currently running; if no bus test is running, the attribute group
contains the results of the most recently completed bus test. The
attributes of the Results group are reset to their initial values
whenever a bus test is started or any attribute in the Setup group is
set. SEQUENCE OF MscShelfBusTestResultsEntry .1.3.6.1.4.1.562.36.2.1.13.3.2.12 |
mscShelfBusTestResultsEntryAn entry in the mscShelfBusTestResultsTable. MscShelfBusTestResultsEntry .1.3.6.1.4.1.562.36.2.1.13.3.2.12.1 |
mscShelfBusTestElapsedTimeThis attribute records the length of time (in minutes) that the bus
test has been running.ro Unsigned32 .1.3.6.1.4.1.562.36.2.1.13.3.2.12.1.1 |
mscShelfBusTestTimeRemainingThis attribute records the maximum length of time (in minutes) that
the bus test will continue to run before stopping.ro Unsigned32 .1.3.6.1.4.1.562.36.2.1.13.3.2.12.1.2 |
mscShelfBusTestCauseOfTerminationThis attribute records the reason the bus test ended. It contains one
of the following values.
neverStarted: the bus test has not been started
testRunning: the bus test is currently running
testTimeExpired: the bus test ran for the specified duration
stoppedByOperator: a STOP command was issued
selfTestFailure: a failure was detected during the bus tap self-test
clockSourceFailure: a failure was detected during the test of the
active control processor (CP) clock source
broadcastFailure: a failure was detected during the broadcast testro Enumeration .1.3.6.1.4.1.562.36.2.1.13.3.2.12.1.3 |
mscShelfBusTestTestsDoneThis attribute records the tests that have been performed during the
bus test. It may contain zero or more of the following values.
selfTest: the bus tap self-test has been performed
clockSourceTest: the clock source test has been performed
broadcastTest: the broadcast test has been performed
pingTest: at least one ping test has been performed
Description of bits:
selfTest(0)
clockSourceTest(1)
broadcastTest(2)
pingTest(3)ro OCTET STRING .1.3.6.1.4.1.562.36.2.1.13.3.2.12.1.4 |
mscShelfBusTestSelfTestResultsTableThis attribute records the results of the bus tap self-test, indexed by
the slot number of the card containing the bus tap tested. Each entry
contains one of the following values.
+: the bus tap passed its self-test
X: the bus tap failed its self-test
.: the bus tap was not tested
The bus test terminates automatically if a failure is detected. SEQUENCE OF MscShelfBusTestSelfTestResultsEntry .1.3.6.1.4.1.562.36.2.1.13.3.2.248 |
mscShelfBusTestSelfTestResultsEntryAn entry in the mscShelfBusTestSelfTestResultsTable. MscShelfBusTestSelfTestResultsEntry .1.3.6.1.4.1.562.36.2.1.13.3.2.248.1 |
mscShelfBusTestSelfTestResultsIndexThis variable represents the mscShelfBusTestSelfTestResultsTable
specific index for the mscShelfBusTestSelfTestResultsTable. Integer32 .1.3.6.1.4.1.562.36.2.1.13.3.2.248.1.1 |
mscShelfBusTestSelfTestResultsValueThis variable represents an individual value for the
mscShelfBusTestSelfTestResultsTable.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.3.2.248.1.2 |
mscShelfBusTestClockSourceTestResultsTableThis attribute records the results of the clock source test, indexed by
the clock source and the slot number of the card containing the bus
tap tested. Each entry contains one of the following values.
+: the bus tap was able to receive clock signals from the clock
source
X: the bus tap was unable to receive clock signals from the clock
source
.: the bus tap was not tested against the clock source
The bus test terminates automatically if a failure is detected
involving the active control processor (CP) clock source. SEQUENCE OF MscShelfBusTestClockSourceTestResultsEntry .1.3.6.1.4.1.562.36.2.1.13.3.2.249 |
mscShelfBusTestClockSourceTestResultsEntryAn entry in the mscShelfBusTestClockSourceTestResultsTable. MscShelfBusTestClockSourceTestResultsEntry .1.3.6.1.4.1.562.36.2.1.13.3.2.249.1 |
mscShelfBusTestClockSourceTestResultsSourceIndexThis variable represents the next to last index for the
mscShelfBusTestClockSourceTestResultsTable. Enumeration .1.3.6.1.4.1.562.36.2.1.13.3.2.249.1.1 |
mscShelfBusTestClockSourceTestResultsCardIndexThis variable represents the final index for the
mscShelfBusTestClockSourceTestResultsTable. Integer32 .1.3.6.1.4.1.562.36.2.1.13.3.2.249.1.2 |
mscShelfBusTestClockSourceTestResultsValueThis variable represents an individual value for the
mscShelfBusTestClockSourceTestResultsTable.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.3.2.249.1.3 |
mscShelfBusTestBroadcastTestResultsTableThis attribute records the results of the broadcast test, indexed by
the slot numbers of the cards containing the bus taps tested. Each
entry contains one of the following values.
+: a broadcast message was successfully sent from the transmitting
bus tap to the receiving bus tap
X: a broadcast message was not successfully sent from the
transmitting bus tap to the receiving bus tap
.: the associated pair of bus taps was not tested
The bus test terminates automatically if a failure is detected. SEQUENCE OF MscShelfBusTestBroadcastTestResultsEntry .1.3.6.1.4.1.562.36.2.1.13.3.2.250 |
mscShelfBusTestBroadcastTestResultsEntryAn entry in the mscShelfBusTestBroadcastTestResultsTable. MscShelfBusTestBroadcastTestResultsEntry .1.3.6.1.4.1.562.36.2.1.13.3.2.250.1 |
mscShelfBusTestBroadcastTestResultsTxCardIndexThis variable represents the next to last index for the
mscShelfBusTestBroadcastTestResultsTable. Integer32 .1.3.6.1.4.1.562.36.2.1.13.3.2.250.1.1 |
mscShelfBusTestBroadcastTestResultsRxCardIndexThis variable represents the final index for the
mscShelfBusTestBroadcastTestResultsTable. Integer32 .1.3.6.1.4.1.562.36.2.1.13.3.2.250.1.2 |
mscShelfBusTestBroadcastTestResultsValueThis variable represents an individual value for the
mscShelfBusTestBroadcastTestResultsTable.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.3.2.250.1.3 |
mscShelfBusTestPingTestsTableThis attribute records the number of ping tests performed, indexed
by the slot numbers of the cards containing the bus taps involved.
Each test attempts to transmit a single low-priority frame from the
transmitting bus tap to the receiving bus tap. SEQUENCE OF MscShelfBusTestPingTestsEntry .1.3.6.1.4.1.562.36.2.1.13.3.2.251 |
mscShelfBusTestPingTestsEntryAn entry in the mscShelfBusTestPingTestsTable. MscShelfBusTestPingTestsEntry .1.3.6.1.4.1.562.36.2.1.13.3.2.251.1 |
mscShelfBusTestPingTestsTxCardIndexThis variable represents the next to last index for the
mscShelfBusTestPingTestsTable. Integer32 .1.3.6.1.4.1.562.36.2.1.13.3.2.251.1.1 |
mscShelfBusTestPingTestsRxCardIndexThis variable represents the final index for the
mscShelfBusTestPingTestsTable. Integer32 .1.3.6.1.4.1.562.36.2.1.13.3.2.251.1.2 |
mscShelfBusTestPingTestsValueThis variable represents an individual value for the
mscShelfBusTestPingTestsTable.ro Unsigned32 .1.3.6.1.4.1.562.36.2.1.13.3.2.251.1.3 |
mscShelfBusTestPingFailuresTableThis attribute records the number of ping test failures detected,
indexed by the slot numbers of the cards containing the bus taps
involved. Each failure represents a single low-priority frame that
was not successfully transmitted from the transmitting bus tap to the
receiving bus tap. The bus test does not terminate automatically if a
failure is detected. SEQUENCE OF MscShelfBusTestPingFailuresEntry .1.3.6.1.4.1.562.36.2.1.13.3.2.252 |
mscShelfBusTestPingFailuresEntryAn entry in the mscShelfBusTestPingFailuresTable. MscShelfBusTestPingFailuresEntry .1.3.6.1.4.1.562.36.2.1.13.3.2.252.1 |
mscShelfBusTestPingFailuresTxCardIndexThis variable represents the next to last index for the
mscShelfBusTestPingFailuresTable. Integer32 .1.3.6.1.4.1.562.36.2.1.13.3.2.252.1.1 |
mscShelfBusTestPingFailuresRxCardIndexThis variable represents the final index for the
mscShelfBusTestPingFailuresTable. Integer32 .1.3.6.1.4.1.562.36.2.1.13.3.2.252.1.2 |
mscShelfBusTestPingFailuresValueThis variable represents an individual value for the
mscShelfBusTestPingFailuresTable.ro Unsigned32 .1.3.6.1.4.1.562.36.2.1.13.3.2.252.1.3 |
mscShelfBusStateTableThis group contains the three OSI State attributes and the six OSI
Status attributes. The descriptions generically indicate what each
attribute implies about the component. Note that not all the values
and state combinations described here are supported by every
component which uses this group. For component-specific
information and the valid state combinations, refer to NTP 241-
7001-150, Passport Operations and Maintenance Guide. SEQUENCE OF MscShelfBusStateEntry .1.3.6.1.4.1.562.36.2.1.13.3.10 |
mscShelfBusStateEntryAn entry in the mscShelfBusStateTable. MscShelfBusStateEntry .1.3.6.1.4.1.562.36.2.1.13.3.10.1 |
mscShelfBusAdminStateThis attribute indicates the OSI Administrative State of the
component.
The value locked indicates that the component is administratively
prohibited from providing services for its users. A Lock or Lock -
force command has been previously issued for this component.
When the value is locked, the value of usageState must be idle.
The value shuttingDown indicates that the component is
administratively permitted to provide service to its existing users
only. A Lock command was issued against the component and it is
in the process of shutting down.
The value unlocked indicates that the component is administratively
permitted to provide services for its users. To enter this state, issue
an Unlock command to this component.
The OSI Status attributes, if supported by the component, may
provide more details, qualifying the state of the component.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.3.10.1.1 |
mscShelfBusOperationalStateThis attribute indicates the OSI Operational State of the component.
The value enabled indicates that the component is available for
operation. Note that if adminState is locked, it would still not be
providing service.
The value disabled indicates that the component is not available for
operation. For example, something is wrong with the component
itself, or with another component on which this one depends. If the
value is disabled, the usageState must be idle.
The OSI Status attributes, if supported by the component, may
provide more details, qualifying the state of the component.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.3.10.1.2 |
mscShelfBusUsageStateThis attribute indicates the OSI Usage State of the component.
The value idle indicates that the component is not currently in use.
The value active indicates that the component is in use and has
spare capacity to provide for additional users.
The value busy indicates that the component is in use and has no
spare operating capacity for additional users at this time.
The OSI Status attributes, if supported by the component, may
provide more details, qualifying the state of the component.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.3.10.1.3 |
mscShelfBusAvailabilityStatusIf supported by the component, this attribute indicates the OSI
Availability status of the component. Note that, even though it is
defined as a multi-valued set, at most one value is shown to the user.
When no values are in the set, this indicates that either the attribute
is not supported or that none of the status conditions described
below are present.
The value inTest indicates that the resource is undergoing a test
procedure. If adminState is locked or shuttingDown, the normal
users are precluded from using the resource and controlStatus is
reservedForTest. Tests that do not exclude additional users can be
present in any operational or administrative state but the
reservedForTest condition should not be present.
The value failed indicates that the component has an internal fault
that prevents it from operating. The operationalState is disabled.
The value dependency indicates that the component cannot operate
because some other resource on which it depends is unavailable.
The operationalState is disabled.
The value powerOff indicates the resource requires power to be
applied and it is not powered on. The operationalState is disabled.
The value offLine indicates the resource requires a routine
operation (either manual, automatic, or both) to be performed to
place it on-line and make it available for use. The operationalState
is disabled.
The value offDuty indicates the resource is inactive in accordance
with a predetermined time schedule. In the absence of other
disabling conditions, the operationalState is enabled or disabled.
The value degraded indicates the service provided by the
component is degraded in some way, such as in speed or operating
capacity. However, the resource remains available for service. The
operationalState is enabled.
The value notInstalled indicates the resource is not present. The
operationalState is disabled.
The value logFull is not used.
Description of bits:
inTest(0)
failed(1)
powerOff(2)
offLine(3)
offDuty(4)
dependency(5)
degraded(6)
notInstalled(7)
logFull(8)ro OCTET STRING .1.3.6.1.4.1.562.36.2.1.13.3.10.1.4 |
mscShelfBusProceduralStatusIf supported by the component, this attribute indicates the OSI
Procedural status of the component. Note that, even though it is
defined as a multi-valued set, at most one value is shown to the user.
When no values are in the set, this indicates that either the attribute
is not supported or that none of the status conditions described
below are present.
The value initializationRequired indicates (for a resource which
doesn't initialize autonomously) that initialization is required before
it can perform its normal functions, and this procedure has not been
initiated. The operationalState is disabled.
The value notInitialized indicates (for a resource which does
initialize autonomously) that initialization is required before it can
perform its normal functions, and this procedure has not been
initiated. The operationalState may be enabled or disabled.
The value initializing indicates that initialization has been initiated
but is not yet complete. The operationalState may be enabled or
disabled.
The value reporting indicates the resource has completed some
processing operation and is notifying the results. The
operationalState is enabled.
The value terminating indicates the component is in a termination
phase. If the resource doesn't reinitialize autonomously,
operationalState is disabled; otherwise it is enabled or disabled.
Description of bits:
initializationRequired(0)
notInitialized(1)
initializing(2)
reporting(3)
terminating(4)ro OCTET STRING .1.3.6.1.4.1.562.36.2.1.13.3.10.1.5 |
mscShelfBusControlStatusIf supported by the component, this attribute indicates the OSI
Control status of the component. Note that, even though it is defined
as a multi-valued set, at most one value is shown to the user.
When no values are in the set, this indicates that either the attribute
is not supported or that none of the status conditions described
below are present.
The value subjectToTest indicates the resource is available but tests
may be conducted simultaneously at unpredictable times, which
may cause it to exhibit unusual characteristics.
The value partOfServicesLocked indicates that part of the service is
restricted from users of a resource. The adminState is unlocked.
The value reservedForTest indicates that the component is
administratively unavailable because it is undergoing a test
procedure. The adminState is locked.
The value suspended indicates that the service has been
administratively suspended.
Description of bits:
subjectToTest(0)
partOfServicesLocked(1)
reservedForTest(2)
suspended(3)ro OCTET STRING .1.3.6.1.4.1.562.36.2.1.13.3.10.1.6 |
mscShelfBusAlarmStatusIf supported by the component, this attribute indicates the OSI
Alarm status of the component. Note that, even though it is defined
as a multi-valued set, at most one value is shown to the user.
When no values are in the set, this indicates that either the attribute
is not supported or that none of the status conditions described
below are present.
The value underRepair indicates the component is currently being
repaired. The operationalState is enabled or disabled.
The value critical indicates one or more critical alarms are
outstanding against the component. Other, less severe, alarms may
also be outstanding. The operationalState is enabled or disabled.
The value major indicates one or more major alarms are
outstanding against the component. Other, less severe, alarms may
also be outstanding. The operationalState is enabled or disabled.
The value minor indicates one or more minor alarms are
outstanding against the component. Other, less severe, alarms may
also be outstanding. The operationalState is enabled or disabled.
The value alarmOutstanding generically indicates that an alarm of
some severity is outstanding against the component.
Description of bits:
underRepair(0)
critical(1)
major(2)
minor(3)
alarmOutstanding(4)ro OCTET STRING .1.3.6.1.4.1.562.36.2.1.13.3.10.1.7 |
mscShelfBusStandbyStatusIf supported by the component, this attribute indicates the OSI
Standby status of the component.
The value notSet indicates that either the attribute is not supported
or that none of the status conditions described below are present.
Note that this is a non-standard value, used because the original
specification indicated this attribute was set-valued and thus, did not
provide a value to indicate that none of the other three are
applicable.
The value hotStandby indicates that the resource is not providing
service but will be immediately able to take over the role of the
resource to be backed up, without initialization activity, and
containing the same information as the resource to be backed up.
The value coldStandby indicates the resource is a backup for
another resource but will not be immediately able to take over the
role of the backed up resource and will require some initialization
activity.
The value providingService indicates that this component, as a
backup resource, is currently backing up another resource.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.3.10.1.8 |
mscShelfBusUnknownStatusThis attribute indicates the OSI Unknown status of the component.
The value false indicates that all of the other OSI State and Status
attribute values can be considered accurate.
The value true indicates that the actual state of the component is not
known for sure.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.3.10.1.9 |
mscShelfBusOperTableThis attribute group contains operational attributes of a bus. SEQUENCE OF MscShelfBusOperEntry .1.3.6.1.4.1.562.36.2.1.13.3.11 |
mscShelfBusOperEntryAn entry in the mscShelfBusOperTable. MscShelfBusOperEntry .1.3.6.1.4.1.562.36.2.1.13.3.11.1 |
mscShelfBusClockSourceThis attribute records the source of the fundamental clock signal
and end-of-cell synchronization signal used by the bus. It contains
one of the following values.
activeCP: the card which is the active control processor (CP) is
providing clock signals
alternate: the card at the opposite end of the module from the active
CP is providing clock signalsro Enumeration .1.3.6.1.4.1.562.36.2.1.13.3.11.1.1 |
mscShelfBusUtilizationThis attribute records how much of the available bus bandwidth was
actually used during the most recently sampled 1 second interval.
The value is expressed as a percentage.ro Unsigned32 .1.3.6.1.4.1.562.36.2.1.13.3.11.1.2 |
mscShelfBusBusTapStatusTableThis attribute records the operability of each bus tap on the bus, as
reported by the associated BusTap component; the entries are
indexed by slot number of the card. Each entry contains one of the
following values.
ok: the bus tap is operational
failed: the bus tap has failed
none: the bus tap status is not availablethe associated BusTap
component does not currently exist SEQUENCE OF MscShelfBusBusTapStatusEntry .1.3.6.1.4.1.562.36.2.1.13.3.246 |
mscShelfBusBusTapStatusEntryAn entry in the mscShelfBusBusTapStatusTable. MscShelfBusBusTapStatusEntry .1.3.6.1.4.1.562.36.2.1.13.3.246.1 |
mscShelfBusBusTapStatusIndexThis variable represents the mscShelfBusBusTapStatusTable
specific index for the mscShelfBusBusTapStatusTable. Integer32 .1.3.6.1.4.1.562.36.2.1.13.3.246.1.1 |
mscShelfBusBusTapStatusValueThis variable represents an individual value for the
mscShelfBusBusTapStatusTable.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.3.246.1.2 |
mscShelfBusClockSourceStatusTableThis vector attribute, indexed with activeCP or alternate, represents
the state of the bus clock sources. It can be set to one of the
following values:
ok: all operational cards can receive signals from the clock source.
failed: at least one operational card is unable to receive signals from
the clock source.
unknown: status of a clock source is unknown. To determine the
status of the clock source, a test must be run.
testInProgress: the clock source is currently being tested.
notApplicable: the LP state of the clock source's card is down or
not provisioned. SEQUENCE OF MscShelfBusClockSourceStatusEntry .1.3.6.1.4.1.562.36.2.1.13.3.247 |
mscShelfBusClockSourceStatusEntryAn entry in the mscShelfBusClockSourceStatusTable. MscShelfBusClockSourceStatusEntry .1.3.6.1.4.1.562.36.2.1.13.3.247.1 |
mscShelfBusClockSourceStatusIndexThis variable represents the mscShelfBusClockSourceStatusTable
specific index for the mscShelfBusClockSourceStatusTable. Enumeration .1.3.6.1.4.1.562.36.2.1.13.3.247.1.1 |
mscShelfBusClockSourceStatusValueThis variable represents an individual value for the
mscShelfBusClockSourceStatusTable.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.3.247.1.2 |
mscShelfTest OBJECT IDENTIFIER .1.3.6.1.4.1.562.36.2.1.13.4 |
mscShelfTestRowStatusTableThis entry controls the addition and deletion of
mscShelfTest components. SEQUENCE OF MscShelfTestRowStatusEntry .1.3.6.1.4.1.562.36.2.1.13.4.1 |
mscShelfTestRowStatusEntryA single entry in the table represents a single
mscShelfTest component. MscShelfTestRowStatusEntry .1.3.6.1.4.1.562.36.2.1.13.4.1.1 |
mscShelfTestRowStatusThis variable is used as the basis for SNMP naming of
mscShelfTest components.
These components cannot be added nor deleted.ro RowStatus (SNMPv2-TC) .1.3.6.1.4.1.562.36.2.1.13.4.1.1.1 |
mscShelfTestComponentNameThis variable provides the component's string name for
use with the ASCII Console Interfacero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.562.36.2.1.13.4.1.1.2 |
mscShelfTestStorageTypeThis variable represents the storage type value for the
mscShelfTest tables.ro StorageType (SNMPv2-TC) .1.3.6.1.4.1.562.36.2.1.13.4.1.1.4 |
mscShelfTestIndexThis variable represents the index for the mscShelfTest tables. NonReplicated .1.3.6.1.4.1.562.36.2.1.13.4.1.1.10 |
mscShelfTestProvTableThis group contains provisionable attributes of the Test component. SEQUENCE OF MscShelfTestProvEntry .1.3.6.1.4.1.562.36.2.1.13.4.10 |
mscShelfTestProvEntryAn entry in the mscShelfTestProvTable. MscShelfTestProvEntry .1.3.6.1.4.1.562.36.2.1.13.4.10.1 |
mscShelfTestAutomaticBusClockTestThis attribute specifies whether or not a bus clock source test is
automatically executed after a clock source's LP state changes, and
after failure or recovery of the active CP bus clock source. Since
tests of an alternate bus clock source may cause a minor loss of
traffic, the attribute is set to disabled by default.
If set to enabled, a bus clock source test is automatically executed.
If the status of the corresponding Shelf Bus clockSourceStatus is
changed after the test, an alarm is issued if the status is one of the
following: ok, failed, or unknown.
If set to disabled, no bus clock source test is automatically
executed. However, a test can be executed by the RUN command. If
the status is changed after the test, an alarm is issued if the status is
one of the following: ok, or failed.rw Enumeration .1.3.6.1.4.1.562.36.2.1.13.4.10.1.1 |
mscShelfTestSetupTableThis attribute group contains the attributes that govern the operation
of a shelf test. SEQUENCE OF MscShelfTestSetupEntry .1.3.6.1.4.1.562.36.2.1.13.4.11 |
mscShelfTestSetupEntryAn entry in the mscShelfTestSetupTable. MscShelfTestSetupEntry .1.3.6.1.4.1.562.36.2.1.13.4.11.1 |
mscShelfTestTypetype
The attribute determines the test to be executed when the RUN
command is applied to the component. Note that running a
busClock test may cause a minor loss of traffic.rw Enumeration .1.3.6.1.4.1.562.36.2.1.13.4.11.1.1 |
mscShelfTestResultsTableThis attribute group contains the results of the Shelf Test that is
currently running; if no test is running, the attribute group contains
the results of the most recently completed Shelf Test. The attributes
of the Results group are reset to their initial values whenever a
corresponding Shelf Test is run or the corresponding attribute of the
Setup group is set. SEQUENCE OF MscShelfTestResultsEntry .1.3.6.1.4.1.562.36.2.1.13.4.12 |
mscShelfTestResultsEntryAn entry in the mscShelfTestResultsTable. MscShelfTestResultsEntry .1.3.6.1.4.1.562.36.2.1.13.4.12.1 |
mscShelfTestBusClockTestResultbusClockTestResult
This attribute records the result of the bus clock manual test. The
result can be one of the following values.
pass : the test passed
fail : the test failed
noTest : the test was not executed when RUN command is issued,
because the shelf was in single bus mode.ro Enumeration .1.3.6.1.4.1.562.36.2.1.13.4.12.1.1 |
busMIB OBJECT IDENTIFIER .1.3.6.1.4.1.562.36.2.2.144 |
IMPORTS Unknown .1.3.6.1.4.1.562.36.2.2.144 |
busGroup OBJECT IDENTIFIER .1.3.6.1.4.1.562.36.2.2.144.1 |
busGroupCA OBJECT IDENTIFIER .1.3.6.1.4.1.562.36.2.2.144.1.1 |
busGroupCA02 OBJECT IDENTIFIER .1.3.6.1.4.1.562.36.2.2.144.1.1.3 |
busGroupCA02A OBJECT IDENTIFIER .1.3.6.1.4.1.562.36.2.2.144.1.1.3.2 |
busCapabilities OBJECT IDENTIFIER .1.3.6.1.4.1.562.36.2.2.144.3 |
busCapabilitiesCA OBJECT IDENTIFIER .1.3.6.1.4.1.562.36.2.2.144.3.1 |
busCapabilitiesCA02 OBJECT IDENTIFIER .1.3.6.1.4.1.562.36.2.2.144.3.1.3 |
busCapabilitiesCA02A OBJECT IDENTIFIER .1.3.6.1.4.1.562.36.2.2.144.3.1.3.2 |