NEC-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
445
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
445 total| Object Name |
|---|
nec OBJECT IDENTIFIER .1.3.6.1.4.1.119 |
RFC1155-SMI Unknown .1.3.6.1.4.1.119 |
necProduct OBJECT IDENTIFIER .1.3.6.1.4.1.119.1 |
atomis OBJECT IDENTIFIER .1.3.6.1.4.1.119.1.14 |
m7-phase2 OBJECT IDENTIFIER .1.3.6.1.4.1.119.1.14.9 |
m7-corporate OBJECT IDENTIFIER .1.3.6.1.4.1.119.1.14.12 |
nec-mib OBJECT IDENTIFIER .1.3.6.1.4.1.119.2 |
necProductDepend OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3 |
atomis-mib OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14 |
m7-phase2-mib OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9 |
node OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.1 |
nodeStatus OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.1.1 |
nodeStatusOperStatusIndicate operational status of the equipment.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.1.1.1 |
nodeStatusStartTimeDate and Time when the equipment was last restartedro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.119.2.3.14.9.1.1.2 |
nodeStatusNodeIdNode ID of the equipmentro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.1.1.3 |
nodeStatusSelfSystemIndicate which system of the SW-Engine the NMS is
connected with.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.1.1.4 |
nodeStatusSwitchTypeIndicate the type of SW-Engine.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.1.1.5 |
nodeStatusFanIndicate operational status of the FAN of the equipment.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.1.1.6 |
nodeStatusEnvironmentPeripheral temperature environment of the equipment.
If the peripheral temperature exceeds 50 C, this object
enters noGood(2).ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.1.1.7 |
nodeStatusTableTable which indicates the status of each part of the
equipment. SEQUENCE OF NodeStatusEntry .1.3.6.1.4.1.119.2.3.14.9.1.2 |
nodeStatusEntryEntry of the configuration of the table. NodeStatusEntry .1.3.6.1.4.1.119.2.3.14.9.1.2.1 |
nodeStatusIndexIndex of the system configuration of the equipment INTEGER .1.3.6.1.4.1.119.2.3.14.9.1.2.1.1 |
nodeStatusPowerIndicate the status of the Power Unit of the equipment.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.1.2.1.2 |
nodeStatusSwitchModeIndicate operational mode of SW-Engine of the equipment.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.1.2.1.3 |
nodeStatusSwitchIndicate the status of the SW-Engine of the equipment.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.1.2.1.4 |
nodePCMCIATableTable which indicates the status of the PCMCIA card.
Every PCMCIA slot is provided with an entry. SEQUENCE OF NodePCMCIAEntry .1.3.6.1.4.1.119.2.3.14.9.1.3 |
nodePCMCIAEntryEntry of nodePCMCIATable NodePCMCIAEntry .1.3.6.1.4.1.119.2.3.14.9.1.3.1 |
nodePCMCIAIndexPCMCIA slot number per SW-Engine INTEGER .1.3.6.1.4.1.119.2.3.14.9.1.3.1.1 |
nodePCMCIAStatusStatus of PCMCIA cardro Enumeration .1.3.6.1.4.1.119.2.3.14.9.1.3.1.2 |
nodePCMCIATypeType of installed PCMCIA cardro Enumeration .1.3.6.1.4.1.119.2.3.14.9.1.3.1.3 |
nodeOpe OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.1.4 |
nodeOpeSaveSave processing.
Save System Configuration information in FROM.
The result is indicated in nodeOpeSaveResult.
The value at read is always noOperation (1).rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.1.4.1 |
nodeOpeSaveResultThe result of SAVE processing
OK/NG indicate that SAVE processing completed/failed,
respectively.
(NearEND) indicates that the number of write counts
approaches to the limit.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.1.4.2 |
nodeOpeCopyCopy the system configuration information/LM to the FROM
of other system.
The result is indicated in nodeOpeCopyResult.
The value at read is always noOperation(1).rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.1.4.3 |
nodeOpeCopyResultResult of the copy processing.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.1.4.4 |
nodeOpeResetSystem Reset processing
The value at read is always noOperation(1).rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.1.4.5 |
slot OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.2 |
slotIfConfTableTable which indicates the line card configuration
of the equipment SEQUENCE OF SlotIfConfEntry .1.3.6.1.4.1.119.2.3.14.9.2.1 |
slotIfConfEntryEntry of the line card configuration SlotIfConfEntry .1.3.6.1.4.1.119.2.3.14.9.2.1.1 |
slotIfConfIndexIndex of line card configurationro INTEGER .1.3.6.1.4.1.119.2.3.14.9.2.1.1.1 |
slotIfConfPhysTypePMD layer/physical layer format of the line card.
Above stated [oc3c], [oc12c] are ATM Form conformed names.
They are corresponding to the ITU-T conformed names as follows:
oc3c - STM1
oc12 - STM4
sts3c - STM1ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.2.1.1.2 |
slotIfConfRevThe revision of the line cards.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.119.2.3.14.9.2.1.1.3 |
slotIfConfStatusOperational status of the line cards.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.2.1.1.4 |
slotIfConfBufferTypeThe Buffer ID of the line cards.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.2.1.1.5 |
slotIfConfBufferRevThe revision of the line card's buffers.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.119.2.3.14.9.2.1.1.6 |
slotIfConfResetLine card reset.
The result of the reset order is indicated in
slotIfConfResetResult.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.2.1.1.7 |
slotIfConfResetResultThe current result of the reset order by slotIfConfReset.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.2.1.1.8 |
linf OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.3 |
linfStatusTableTable related to the ATM specific lines which could not be
defined by MIB-II.
The table includes the configuration information,
operational status and error types of lines. SEQUENCE OF LinfStatusEntry .1.3.6.1.4.1.119.2.3.14.9.3.1 |
linfStatusEntryEntry of the line interface status indication. LinfStatusEntry .1.3.6.1.4.1.119.2.3.14.9.3.1.1 |
linfIndexIndex of the line interface status indicationro INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.1.1.1 |
linfStatusStatus of the line interface or the receive clockro Enumeration .1.3.6.1.4.1.119.2.3.14.9.3.1.1.2 |
linfLoopBackLoop back statusrw Enumeration .1.3.6.1.4.1.119.2.3.14.9.3.1.1.3 |
linfConfLine card type.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.3.1.1.4 |
linfFwdAvailableBandWidthForward Available BandWidth(Mbps).ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.1.1.5 |
linfBkwdAvailableBandWidthBackward Available BandWidth(Mbps).ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.1.1.6 |
linfJ2RateIndicate the line rate of the J2-dedicated line service. Enumeration .1.3.6.1.4.1.119.2.3.14.9.3.1.1.7 |
linfCacFactorrw INTEGER(0|10..1000) .1.3.6.1.4.1.119.2.3.14.9.3.1.1.8 |
linfLoopBackCausero Enumeration .1.3.6.1.4.1.119.2.3.14.9.3.1.1.9 |
linfBandWidthro INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.1.1.10 |
linfRecommendationro Enumeration .1.3.6.1.4.1.119.2.3.14.9.3.1.1.11 |
linfUnassignedIdleUnassigned/Idlero Enumeration .1.3.6.1.4.1.119.2.3.14.9.3.1.1.12 |
linfMaxActiveVpiBitsThe length of valid VPI bits.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.1.1.13 |
linfMaxActiveVciBitsThe length of valid VCI bits.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.1.1.14 |
linfPhysTypero INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.1.1.15 |
linfParam1ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.1.1.16 |
linfParam2ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.1.1.17 |
linfParam3ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.1.1.18 |
linfParam4ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.1.1.19 |
linfParam5ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.1.1.20 |
linfParam6ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.1.1.21 |
linfParam7ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.1.1.22 |
linfFifoConfTableIndicate status of FIFO on the shaper-line card.
*
* Relationship between PCR, SCR and MBS value.
PCR >= SCR
PCR >= MBS SEQUENCE OF LinfFifoConfEntry .1.3.6.1.4.1.119.2.3.14.9.3.2 |
linfFifoConfEntryEntry of FIFO status indication LinfFifoConfEntry .1.3.6.1.4.1.119.2.3.14.9.3.2.1 |
linfFifoConfifIndexLine Interface Index INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.2.1.1 |
linfFifoConfIndexIndex of FIFO INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.2.1.2 |
linfFifoConfStatusStatus of FIFO Enumeration .1.3.6.1.4.1.119.2.3.14.9.3.2.1.3 |
linfFifoConfPeekRatePeak Cell rate (PCR) for shaper-line card. INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.2.1.4 |
linfFifoConfSustainRateSustainable Cell Rate ( SCR) for shaper-line card. INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.2.1.5 |
linfFifoConfMaxBurstSizeMaximum Burst Size (MBS) for the shaper-line card. INTEGER .1.3.6.1.4.1.119.2.3.14.9.3.2.1.6 |
linfFifoConfRowStatusThis object is used to designate the setting method for
the shaping rate from the manager.
Also, this object returns the reply to the shaping rate
setting request from the agent side.
- 'active', which indicates that the
conceptual row is available for use by the
managed device;
- 'notInService', which indicates that the
conceptual row exists in the agent, but is
unavailable for use by the managed device;
- 'notReady', which indicates that the
conceptual row exists in the agent, but is
missing information necessary in order to be
available for use by the managed device;
- 'createAndGo', which is supplied by a
management station wishing to create a new
instance of a conceptual row and to have it
available for use by the managed device;
- 'createAndWait', which is supplied by a
management station wishing to create a new
instance of a conceptual row but not to have
it available for use by the managed device;
and,
- 'destroy', which is supplied by a
management station wishing to delete all of
the instances associated with an existing
conceptual row. Enumeration .1.3.6.1.4.1.119.2.3.14.9.3.2.1.7 |
conn OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.4 |
connPvc OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.4.1 |
connPvcOpe OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.4.1.1 |
connPvcOpeLowPortLow-side line port number.rw INTEGER (1..65|-1) -- .1.3.6.1.4.1.119.2.3.14.9.4.1.1.1 |
connPvcOpeLowVpiLow-side VPI number.rw INTEGER (0..16383|-1) -- default value is -1. .1.3.6.1.4.1.119.2.3.14.9.4.1.1.2 |
connPvcOpeLowVciLow-side VCI number.rw INTEGER (0..16383|-1) -- .1.3.6.1.4.1.119.2.3.14.9.4.1.1.3 |
connPvcOpeHighPortHigh-side line port number.rw INTEGER (1..65|-1) -- default value is -1. .1.3.6.1.4.1.119.2.3.14.9.4.1.1.4 |
connPvcOpeHighVpiHigh-side VPI number.rw INTEGER (0..16383|-1) -- default value is -1. .1.3.6.1.4.1.119.2.3.14.9.4.1.1.5 |
connPvcOpeHighVciHigh-side VCI number.rw INTEGER (0..16383|-1) -- default value is -1. .1.3.6.1.4.1.119.2.3.14.9.4.1.1.6 |
connPvcOpeTopologyTopology of the Connection.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.1.1.7 |
connPvcOpeTrafficTypeTraffic Type.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.1.1.8 |
connPvcOpeStatusrw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.1.1.9 |
connPvcOpeCauseThe result of the connection operation.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.1.1.10 |
connPvcOpeLowFifoIndexShaper number of Forward.
If shaping is not performed, designate 0.rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.1.11 |
connPvcOpeHighFifoIndexShaper number of Backward.
If shaping is not performed, designate 0.rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.1.12 |
connPvcOpeLowParam1UPC mode of Forward.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.1.1.13 |
connPvcOpeHighParam1UPC mode of Backward.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.1.1.14 |
connPvcOpeLowParam2Profile name of Forward.
If nothing is designated, the string of size(0) is designated.rw DisplayString .1.3.6.1.4.1.119.2.3.14.9.4.1.1.15 |
connPvcOpeHighParam2Profile name of Backward.
If nothing is designated, the string of size(0) is designated.rw DisplayString .1.3.6.1.4.1.119.2.3.14.9.4.1.1.16 |
connPvcTable SEQUENCE OF ConnPvcEntry .1.3.6.1.4.1.119.2.3.14.9.4.1.2 |
connPvcEntryEntry of connPvcTable.
e.g.
receive +
=======>| uni-directional-VCC |=======>
(1/0/32)| |(2/0/32)
=======>| bi-directional-VCC |=======>
(1/0/33)| |(2/0/33)
=======>| broadcast - VCC
(1/0/34)| | |(2/0/34)
| + |=======>
| |(3/0/34)
+
(line/vpi/vci)
connPvcContrastPort.1.0.32.1.1=2
connPvcContrastPort.2.0.32.2.1=1
connPvcContrastPort.1.0.33.3.1=2
connPvcContrastPort.2.0.33.3.1=1
connPvcContrastPort.1.0.34.5.1=2
connPvcContrastPort.1.0.34.5.2=3
connPvcContrastPort.2.0.34.4.1=1
connPvcContrastPort.3.0.34.4.1=1 ConnPvcEntry .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1 |
connPvcPortLine port number INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.1 |
connPvcVpiVPI number INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.2 |
connPvcVciVCI number INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.3 |
connPvcDirectionIndicate cell flow. Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.4 |
connPvcIndex INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.5 |
connPvcContrastPortro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.6 |
connPvcContrastVpiro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.7 |
connPvcContrastVciro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.8 |
connPvcTopologyTopology of the Connection.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.9 |
connPvcTrafficTypeTraffic Type.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.10 |
connPvcFifoIndexThe Shaper numbers of the direction from this endpoint to
the endpoint to be switched.
Value 0 means that Shaping will not be performed.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.11 |
connPvcContrastFifoIndexThe Shaper number of the direction from the endpoint to
be switched to this end point.
Value 0 means that Shaping will not be performed.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.12 |
connPvcTrfConfIndicate Traffic control/status.
If a path does not exist, noSuchName.
1. Indicate Traffic status
1) entry...registered
2) remove...not registered(initial status)
2. Register Traffic
1) Set connPvcTrfConf to 'entry', to perform the
registration process.
2) Then, get connPvcTrfResult. For normal end,
it contains entrySucceed, for abnormal end,
it contains other value.
3. Delete Traffic
1) Set connPvcTrfConf to 'remove', to perform the
deletion process.
2) Then, get connPvTrfResult. For normal end, it
contains entrySucceed, for abnormal end, it contains
other value.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.13 |
connPvcTrfResultIndicate the processing result after Traffic control.
If the path does not exist, noSuchName.
The result of the registration
EntrySucceed (2)
AlreadyEntry (3)
tableOverflow (4)
over the limit.
The result of the deletion
RemoveSucceed (5)
notEntry (6)
Normally, other (1) is indicated. It is the current status
just after the traffic control. Once, the traffic control
is got, then it returns to other (1).ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.14 |
connPvcParam1UPC mode of the direction from this endpoint to
the endpoint to be switched.
If nothing is designated, or the designation is invalid,
off (1) is indicated.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.15 |
connPvcContrastParam1UPC mode of the direction from the endpoint to
be switched to this end point.
If nothing is designated, or the designation is invalid,
off (1) is indicated.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.16 |
connPvcParam2Profile name of the direction from this endpoint to
the endpoint to be switched.
If nothing is designated, or the designation is invalid,
the string of size(0) is indicated.ro DisplayString .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.17 |
connPvcContrastParam2Profile name of the direction from the endpoint to
be switched to this end point.
If nothing is designated, or the designation is invalid,
the string of size(0) is indicated.ro DisplayString .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.18 |
connPvcParam3PCR[cell/s] of the direction from this endpoint to
the endpoint to be switched.
If the value is invalid, -1 is indicated.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.19 |
connPvcContrastParam3PCR[cell/s] of the direction from the endpoint to
be switched to this end point.
If the value is invalid, -1 is indicated.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.20 |
connPvcParam4SCR[cell/s] of the direction from this endpoint to
the endpoint to be switched.
If the value is invalid, -1 is indicated.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.21 |
connPvcContrastParam4SCR[cell/s] of the direction from the endpoint to
be switched to this end point.
If the value is invalid, -1 is indicated.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.22 |
connPvcParam5MBS[cell] of the direction from this endpoint to
the endpoint to be switched.
If the value is invalid, -1 is indicated.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.23 |
connPvcContrastParam5MBS[cell] of the direction from the endpoint to
be switched to this end point.
If the value is invalid, -1 is indicated.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.24 |
connPvcParam6EPD(Early Packet Discard) of the direction from this endpoint
to the endpoint to be switched.
Indicate if the discard processing in the unit of AAL5
packet should be performed or not when the threshold is
exceeded.
If the value is invalid, off(1) is indicated.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.25 |
connPvcContrastParam6EPD(Early Packet Discard) of the direction from the endpoint
to be switched to this end point.
Indicate if the discard processing in the unit of AAL5
packet should be performed or not when the threshold is
exceeded.
If the value is invalid, off(1) is indicated.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.26 |
connPvcParam7MCR[cell/s]. Not supported here. INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.27 |
connPvcContrastParam7MCR[cell/s]. Not supported here. INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.1.2.1.28 |
connPvcTrfTableIndicate traffic counter information per connection. SEQUENCE OF ConnPvcTrfEntry .1.3.6.1.4.1.119.2.3.14.9.4.1.3 |
connPvcTrfEntryEntry of traffic per connection.
Every INDEX is equivalent to the one defined in connPvcEntry. ConnPvcTrfEntry .1.3.6.1.4.1.119.2.3.14.9.4.1.3.1 |
connPvcTrfInCellsThe number of receive cells 64 bit counterro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.4.1.3.1.1 |
connPvcTrfInCellsCountersThe number of receive cells 32 bit counterro Counter .1.3.6.1.4.1.119.2.3.14.9.4.1.3.1.2 |
connPvcTrfOutCellsThe number of transmit cells 64 bit counterro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.4.1.3.1.3 |
connPvcTrfOutCellsCountersThe number of transmit cells 32 bit counterro Counter .1.3.6.1.4.1.119.2.3.14.9.4.1.3.1.4 |
connPvcTrfInDropCellsThe number of receive drop cells 64 bit counterro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.4.1.3.1.5 |
connPvcTrfInDropCellsCountersThe number of receive drop cells 32 bit counterro Counter .1.3.6.1.4.1.119.2.3.14.9.4.1.3.1.6 |
connConf OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.4.2 |
connConfNode OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.4.2.1 |
connConfNodePvcsThe number of current established PVCs in this switch.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.2.1.1 |
connConfNodeSvcsThe number of current established SVCs in this switch.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.2.1.2 |
connConfNodeSoftPvcsThe number of current established Soft PVPCs/PVCCs in
this switch.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.2.1.3 |
connConfNodeTrafClearSet allClear (1) to clear all traffic registration information.
If noOperation (2) is written, nothing will be performed.
The value at read is always noOperation (2).rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.2.1.4 |
connConfNodeTrafsThe number of traffic registrations which are being set
in the switch.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.2.1.5 |
connConfNodeCompleteSvcsThe number of SVC complete callsro Counter .1.3.6.1.4.1.119.2.3.14.9.4.2.1.6 |
connConfNodeUnCompleteSvcsThe number of SVC incomplete callsro Counter .1.3.6.1.4.1.119.2.3.14.9.4.2.1.7 |
connConfIfTableThe table is used to show the information of current
established connections on the interface. SEQUENCE OF ConnConfIfEntry .1.3.6.1.4.1.119.2.3.14.9.4.2.2 |
connConfIfEntryEntry of connConfIfTable. ConnConfIfEntry .1.3.6.1.4.1.119.2.3.14.9.4.2.2.1 |
connConfIfPvcsThe number of current established PVCs
on the interface.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.2.2.1.1 |
connConfIfSvcsThe number of current established SVCs
on the interface.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.2.2.1.2 |
connConfIfSoftPvcsThe number of current established Soft PVPCs/PVCCs
on the interface.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.2.2.1.3 |
connRoute OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.4.3 |
connRouteOpe OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.4.3.1 |
connRouteOpeStatusallocate : allocate the right to operate the routing
information to a manager.
add : add the routing information
to static routing table.
delete : delete the routing information
from static routing table.
free : free the right to operate the routing
information from a manager.
+-+
| |
+-+
| ++ |
| |
| ++ +
>|allocate| -> |add/delete|-
++ +rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.3.1.1 |
connRouteOpeFailureCauseThe result of the operation.ro ConnRouteOpeFailureCause .1.3.6.1.4.1.119.2.3.14.9.4.3.1.2 |
connRouteOpeAddressFormatrw DstAtmAddressFormat .1.3.6.1.4.1.119.2.3.14.9.4.3.1.3 |
connRouteOpeAddressLengthrw DstAtmAddressLength .1.3.6.1.4.1.119.2.3.14.9.4.3.1.4 |
connRouteOpeAddressrw DstAtmAddress .1.3.6.1.4.1.119.2.3.14.9.4.3.1.5 |
connRouteOpePrimaryIfIndexrw DstPrimaryIfIndex .1.3.6.1.4.1.119.2.3.14.9.4.3.1.6 |
connRouteOpePrimaryVPIrw DstPrimaryVPI .1.3.6.1.4.1.119.2.3.14.9.4.3.1.7 |
connRouteOpeSecondaryIfIndexrw DstSecondaryIfIndex .1.3.6.1.4.1.119.2.3.14.9.4.3.1.8 |
connRouteOpeSecondaryVPIrw DstSecondaryVPI .1.3.6.1.4.1.119.2.3.14.9.4.3.1.9 |
connRouteOpeTertiaryIfIndexrw DstSecondaryIfIndex .1.3.6.1.4.1.119.2.3.14.9.4.3.1.10 |
connRouteOpeTertiaryVPIrw DstSecondaryVPI .1.3.6.1.4.1.119.2.3.14.9.4.3.1.11 |
connRouteOpeFourthryIfIndexrw DstSecondaryIfIndex .1.3.6.1.4.1.119.2.3.14.9.4.3.1.12 |
connRouteOpeFourthryVPIrw DstSecondaryVPI .1.3.6.1.4.1.119.2.3.14.9.4.3.1.13 |
connRouteOpeFifthryIfIndexrw DstSecondaryIfIndex .1.3.6.1.4.1.119.2.3.14.9.4.3.1.14 |
connRouteOpeFifthryVPIrw DstSecondaryVPI .1.3.6.1.4.1.119.2.3.14.9.4.3.1.15 |
connRouteOpeSixthryIfIndexrw DstSecondaryIfIndex .1.3.6.1.4.1.119.2.3.14.9.4.3.1.16 |
connRouteOpeSixthryVPIrw DstSecondaryVPI .1.3.6.1.4.1.119.2.3.14.9.4.3.1.17 |
connRouteOpeSeventhryIfIndexrw DstSecondaryIfIndex .1.3.6.1.4.1.119.2.3.14.9.4.3.1.18 |
connRouteOpeSeventhryVPIrw DstSecondaryVPI .1.3.6.1.4.1.119.2.3.14.9.4.3.1.19 |
connRouteTableThis table is used to show the static routing table for SVC. SEQUENCE OF ConnRouteEntry .1.3.6.1.4.1.119.2.3.14.9.4.3.2 |
connRouteEntryEntry of connRouteTable. ConnRouteEntry .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1 |
connRouteTypeThe value of this object shows the routing type.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.1 |
connRoutePrimaryIfIndexro DstPrimaryIfIndex .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.2 |
connRoutePrimaryVPIro DstPrimaryVPI .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.3 |
connRouteSecondaryIfIndexro DstSecondaryIfIndex .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.4 |
connRouteSecondaryVPIro DstSecondaryVPI .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.5 |
connRouteTertiaryIfIndexro DstSecondaryIfIndex .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.6 |
connRouteTertiaryVPIro DstSecondaryVPI .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.7 |
connRouteFourthryIfIndexro DstSecondaryIfIndex .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.8 |
connRouteFourthryVPIro DstSecondaryVPI .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.9 |
connRouteFifthryIfIndexro DstSecondaryIfIndex .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.10 |
connRouteFifthryVPIro DstSecondaryVPI .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.11 |
connRouteSixthryIfIndexro DstSecondaryIfIndex .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.12 |
connRouteSixthryVPIro DstSecondaryVPI .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.13 |
connRouteSeventhryIfIndexro DstSecondaryIfIndex .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.14 |
connRouteSeventhryVPIro DstSecondaryVPI .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.15 |
connRoutePrimaryStatusOperational status of the primary routing.
If the primary route of the routing table of the
equipment is valid, enable(2), if not valid, disable(1).ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.16 |
connRoutePrimaryCauseCause of the switching from the primary route.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.17 |
connRouteAtmAddressFormat DstAtmAddressFormat .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.18 |
connRouteAtmAddressLength DstAtmAddressLength .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.19 |
connRouteAtmAddress DstAtmAddress .1.3.6.1.4.1.119.2.3.14.9.4.3.2.1.20 |
connSoftPvcIndexNextThis object returns the empty index of the call management
table, required to access to connSoftPvcTable.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.4 |
connSoftPvcTableThis table include all entries to Soft-PVPC/PVCC
currently available between the lines or the line and
CPU port of the switch. Also, this table is used to
set or delete Soft-PVPC/PVCC. The operable
connection form between Soft-PVPC/PVCC is bi-
directional point-to-point only.
The procedure to set the connection is as follows:
1. Acquire connSoftPvcIndex
To set the connection, read connSoftPvcIndexNext and
obtain an index of the Soft-PVPC/PVCC table. The
index must be managed by NMS. (The index is required
to take an action to the connection.)
2. Set createAndWait
Set connSoftPvcRowStatus to CreateAndWait, using the
obtained connSoftPvcIndex as index. If the agent
will set the parameter for the Soft-PVPC/PVCC
setting to the default value and make
connSoftRowStatus to notReady.
However, the same manager cannot create another row
while creating a row (the status of the row is notRedy
or notInService).
3. Get the default value
Get the default value of the object which serves as
parameter for the connection setting. (The agent
shall return -1 if it does not have a default value.)
Default values are as follows:
connSoftPvcTopology bi-directional-VCC(2)
connSoftPvcTrafficType traffic-UBR(5)
connSoftPvcEndpointType calling(1)
connSoftPvcRetry 2
connSoftPvcSrcAtmAddressFormat nsap(2)
connSoftPvcSrcAtmAddressLength None
connSoftPvcSrcAtmAddress 0 length string
connSoftPvcSrcIfIndex None
connSoftPvcSrcVPI None
connSoftPvcSrcVCI None
connSoftPvcDstAtmAddressFormat nsap(2)
connSoftPvcDstAtmAddressLength None
connSoftPvcDstAtmAddress 0 length string
connSoftPvcDstIfIndex None
connSoftPvcDstVPI None
connSoftPvcDstVCI None
connSoftPvcSrcFifoIndex 0
connSoftPvcDstFifoIndex 0
connSoftPvcNodeKind model5(1)
connSoftPvcSrcParam1 off(1)
connSoftPvcDstParam1 off(1)
connSoftPvcSrcParam2 0 length string
connSoftPvcDstParam2 0 length string
connSoftPvcSrcParam3 -1
connSoftPvcDstParam3 -1
connSoftPvcSrcParam4 -1
connSoftPvcDstParam4 -1
connSoftPvcSrcParam5 -1
connSoftPvcDstParam5 -1
connSoftPvcSrcParam6 off(2)
connSoftPvcDstParam6 off(2)
connSoftPvcSrcParam7 None (not installed)
connSoftPvcDstParam7 None (not installed)
4. Set parameter
If a parameter does not have a default value, or the
default value should not be used, set the parameter to
a value.
If all parameters are set, the agent shall make
connSoftPvcRowStatus to notInService.
5. Set active
By doing so, the agent checks parameters, resources and
establishes the connection.
6. Get connSoftPvcRowStatus
If connSoftPvcRowStatus is active, the connection
setting completed successfully, if notInService, the
connection setting failed. For the cause, refer to
connSoftPvcCause.
(Note) When the connection setting has failed, if the
connection is not released, the row will remain.
7. Get connSoftPvcRestRetry
Remaining counts of retry are contained. If it is
positive value, the retry is in progress. If
connSoftPvcRestRetry is 0, the retry completed. The
result of the connection setting should be seen, when
this object is 0.
-1 means that infinite retry is in progress.
***Special pattern***
(1) If connSoftPvcTopology is bi-directional-VPC, set
connSoftPvcSrcVCI, connSoftPvcDstVCI to 0.
The procedure to release the connection is as follows:
1. Set 'destroy'
Set connSoftPvcRowStatus to 'destroy', using
connSoftPvcIndex of the connection to be deleted as
index.
The agent will delete the connection, referring to
it.
(Note) 'destroy' can also be set during the bypass
processing.
2. Get the result
If the connection is deleted, 'get' of
connSoftPvcTable of the designated index becomes
NoSuchName.
The bypass processing of connection
1. Set notInService
When the agent executes the bypass processing of
connection, set connSoftPvcRowStatus to
notInService, and then establish the connection.
2. Get connSoftPvcRowStatus
If connSoftPvcRowStatus is 'active', the bypass
connection setting has completed successfully.
If connSoftPvcRowStatus remains 'notInService',
the connection setting has failed.
Others
1. The cut and recovery processing of connection is
performed, following the delete and set procedures
of the concerned connection.
Each procedure is as stated before. SEQUENCE OF ConnSoftPvcEntry .1.3.6.1.4.1.119.2.3.14.9.4.5 |
connSoftPvcEntryEntry of ATMSoft-PVPC/PVCC connection ConnSoftPvcEntry .1.3.6.1.4.1.119.2.3.14.9.4.5.1 |
connSoftPvcIndexThe value of this object is equal to the
connSoftPvcIndexNext.
1 - 128 : Soft PVPCs/PVCCsro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.5.1.1 |
connSoftPvcTopologyTopology of the Connection.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.5.1.2 |
connSoftPvcTrafficTypeTraffic Type.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.5.1.3 |
connSoftPvcEndpointTypeType of Endpoint.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.5.1.4 |
connSoftPvcRetryNumber of retry.
0 - 15 : Number of retry
-1 : Infinite retryrw INTEGER (0..15|-1) .1.3.6.1.4.1.119.2.3.14.9.4.5.1.5 |
connSoftPvcSrcAtmAddressFormatAtmAdress format.rw ConnSoftPvcSrcAtmAddressFormat .1.3.6.1.4.1.119.2.3.14.9.4.5.1.6 |
connSoftPvcSrcAtmAddressLengthThe valid bit length of connSoftPvcSrcAtmAddress.
The value(-1) is read-only.
The value(4..160) must be a multiple of 4.rw INTEGER (4..160|-1) .1.3.6.1.4.1.119.2.3.14.9.4.5.1.7 |
connSoftPvcSrcAtmAddressNodeId of source node.
Its maximum length is 13 bytes.
This object length is 20 bytes in case AtmAddress is
setting.
If the last semi OCTET is invalid, it is padded
with 0xf.
The value of size(0) is read-only.rw OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.4.5.1.8 |
connSoftPvcSrcIfIndexThe number of the calling line.
(ifIndex of ifEntry)rw INTEGER (1..99|-1) .1.3.6.1.4.1.119.2.3.14.9.4.5.1.9 |
connSoftPvcSrcVPIVPI value of the calling line.rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.5.1.10 |
connSoftPvcSrcVCIVCI value of the calling line.rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.5.1.11 |
connSoftPvcDstAtmAddressFormatAtmAdress format.rw ConnSoftPvcDstAtmAddressFormat .1.3.6.1.4.1.119.2.3.14.9.4.5.1.12 |
connSoftPvcDstAtmAddressLengthThe valid bit length of connSoftPvcDstAtmAddress.
The value(-1) is read-only.
The value(4..160) must be a multiple of 4.rw INTEGER (4..160|-1) .1.3.6.1.4.1.119.2.3.14.9.4.5.1.13 |
connSoftPvcDstAtmAddressNodeId of destination node.
Its maximum length is 13 bytes.
This object length is 20 bytes in case AtmAddress is
setting.
If the last semi OCTET is invalid, it is padded
with 0xf.
The value of size(0) is read-only.rw OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.4.5.1.14 |
connSoftPvcDstIfIndexThe number of the called line.
(ifIndex of ifEntry)65 is GateWay.rw INTEGER (1..99|-1) .1.3.6.1.4.1.119.2.3.14.9.4.5.1.15 |
connSoftPvcDstVPIVPI value of the called line.rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.5.1.16 |
connSoftPvcDstVCIVCI value of the called line.rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.5.1.17 |
connSoftPvcRowStatusIt is used from the manager to order the setting method
of the Soft PVC connection. It is used from the agent side
to return the result of the connection setting request.
- 'active', which indicates that the
conceptual row is available for use by the
managed device;
- 'notInService', which indicates that the
conceptual row exists in the agent, but is
unavailable for use by the managed device;
- 'notReady', which indicates that the
conceptual row exists in the agent, but is
missing information necessary in order to be
available for use by the managed device;
- 'createAndGo', which is supplied by a
management station wishing to create a new
instance of a conceptual row and to have it
available for use by the managed device;
- 'createAndWait', which is supplied by a
management station wishing to create a new
instance of a conceptual row but not to have
it available for use by the managed device;
and,
- 'destroy', which is supplied by a
management station wishing to delete all of
the instances associated with an existing
conceptual row.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.5.1.18 |
connSoftPvcCauseObject to indicate the result of the connection setting.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.5.1.19 |
connSoftPvcRestRetryRemaining number of retry
0 - 15 : Remaining number of retry
-1 : Infinite retry in progressro INTEGER (0..15|-1) .1.3.6.1.4.1.119.2.3.14.9.4.5.1.20 |
connSoftPvcSrcFifoIndexDesignate the Shaper number of the calling line.
If the Shaping is not performed, designate 0.rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.5.1.21 |
connSoftPvcDstFifoIndexDesignate the Shaper number of the called line.
If the Shaping is not performed, designate 0.
However, if the called sw is not furnished with the shaping
function, this value has no meaning.
Since it cannot be recognized if this value is set on the
called side, the value is regarded as 'the value set by
the calling side'.rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.5.1.22 |
connSoftPvcNodeKindDesignate/indicate the machine type on the called side.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.5.1.23 |
connSoftPvcSrcParam1UPC mode of the calling line.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.5.1.24 |
connSoftPvcDstParam1UPC mode of the called line.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.5.1.25 |
connSoftPvcSrcParam2Profile name of Forward.
If nothing is designated, the string of size(0) is designated.rw DisplayString .1.3.6.1.4.1.119.2.3.14.9.4.5.1.26 |
connSoftPvcDstParam2Profile name of Backward.
If nothing is designated, the string of size(0) is designated.rw DisplayString .1.3.6.1.4.1.119.2.3.14.9.4.5.1.27 |
connSoftPvcSrcParam3PCR[cell/s] of Forward.
If the value is invalid, -1 is indicated.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.5.1.28 |
connSoftPvcDstParam3PCR[cell/s] of Backward.
If the value is invalid, -1 is indicated.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.5.1.29 |
connSoftPvcSrcParam4SCR[cell/s] of Forward.
If the value is invalid, -1 is indicated.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.5.1.30 |
connSoftPvcDstParam4SCR[cell/s] of Backward.
If the value is invalid, -1 is indicated.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.5.1.31 |
connSoftPvcSrcParam5MBS[cell] of Forward.
If the value is invalid, -1 is indicated.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.5.1.32 |
connSoftPvcDstParam5MBS[cell] of Backward.
If the value is invalid, -1 is indicated.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.5.1.33 |
connSoftPvcSrcParam6EPD(Early Packet Discard) of Forward.
Indicate if the discard processing in the unit of AAL5
packet should be performed or not when the threshold is
exceeded.
If the value is invalid, off(2) is indicated.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.5.1.34 |
connSoftPvcDstParam6EPD(Early Packet Discard) of Backward.
Indicate if the discard processing in the unit of AAL5
packet should be performed or not when the threshold is
exceeded.
If the value is invalid, off(2) is indicated.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.5.1.35 |
connSoftPvcSrcParam7MCR[cell/s]. Not supported here. INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.5.1.36 |
connSoftPvcDstParam7MCR[cell/s]. Not supported here. INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.5.1.37 |
connSoftPvcEstablishedSrcInfTableThe table regarding the calling node of the Soft
PVPC/PVCC established as called side office by the local node SEQUENCE OF ConnSoftPvcEstablishedSrcInfEntry .1.3.6.1.4.1.119.2.3.14.9.4.6 |
connSoftPvcEstablishedSrcInfEntryThe entry of the calling side node information of the
Soft PVPC/PVCC established as the called side office by
the local node ConnSoftPvcEstablishedSrcInfEntry .1.3.6.1.4.1.119.2.3.14.9.4.6.1 |
connSoftPvcEstablishedSrcInfThe calling node information of the Soft PVPC/PVCC
established as called side office by the node.
The structure of the entry is as follows
struct {
long SrcAtmAddressFormat;
long SrcAtmAddressLength;
char SrcAtmAddress[20];
};
(*1) 'long' data should be stored with 'big endian'.
(*2) For SrcAtmAddress data, if it is less than 20 byte,
the data padded by '0xf' shall be stored.
This information is divided into up to 32 pieces, and each
piece is put into the head 4 bytes (count) of an entry. The
data which contains the number of the entries is described
below.
+-+
| count | (= n)
+-+
| EstSrcInf 1 |
|.................|
| EstSrcInf 2 |
|.................|
| . |
| . |
| . |
|.................|
| EstSrcInf n | ( 1 <= n <= 32 )
+-+ro Opaque .1.3.6.1.4.1.119.2.3.14.9.4.6.1.1 |
connSoftPvcEstSrcInfIndex ConnSoftPvcEstSrcInfIndex .1.3.6.1.4.1.119.2.3.14.9.4.6.1.2 |
connOam OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.4.7 |
connOamOpe OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.4.7.1 |
connOamOpeStatusUsed to set/delete OAM End-point, Connecting-point.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.7.1.1 |
connOamOpeCauseThe result of the processing to set/delete OAM End-point,
Connecting-point.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.7.1.2 |
connOamOpePointEnd-point / Connecting-point.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.7.1.3 |
connOamOpeModeMode. F4 (VP level)/f5 (VC level)rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.7.1.4 |
connOamOpeSectionPoint between segments/End-to-End point.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.7.1.5 |
connOamOpePort1Line numberrw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.7.1.6 |
connOamOpePort2Line number. Upon setting/deleting end-point, don't
care about it.rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.7.1.7 |
connOamOpeVpi1VPI.rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.7.1.8 |
connOamOpeVpi2VPI. Upon setting/deleting end-point, don't care about it.rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.7.1.9 |
connOamOpeVci1VCI.rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.7.1.10 |
connOamOpeVci2VCI.rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.7.1.11 |
connOamTableOAM End-point, Connecting-point indication table SEQUENCE OF ConnOamEntry .1.3.6.1.4.1.119.2.3.14.9.4.7.2 |
connOamEntryOAM End-point, Connecting-point indication entry ConnOamEntry .1.3.6.1.4.1.119.2.3.14.9.4.7.2.1 |
connOamPortLine number INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.1 |
connOamIndexOAM End-point / Connecting-point Index. INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.2 |
connOamContrastPortLine number of the opposite line. For End-point, -1.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.3 |
connOamVpiVPI.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.4 |
connOamContrastVpiOpposite VPI. For End-point, -1.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.5 |
connOamVciVCI. For the f4 level, -1.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.6 |
connOamContrastVciOpposite VCI.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.7 |
connOamPointEnd-point / Connecting-point.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.8 |
connOamModeMode. F4 (VP level)/f5 (VC level).ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.9 |
connOamSectionPoint between segments/End-to-End point.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.10 |
connOamStatusReceive status of end-point.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.11 |
connOamDefectTypeFault cause in the receive cell.
For Connecting-point, return 'normal (1)'.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.12 |
connOamDefectNodeIDNode ID of the Switch which sends alarm transfer cells.
For connecting-point, return '0 length string'.ro OCTET STRING( SIZE (13) ) .1.3.6.1.4.1.119.2.3.14.9.4.7.2.1.13 |
connLoop OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.4.8 |
connLoopOpe OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.4.8.1 |
connLoopOpeStatusrw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.8.1.1 |
connLoopOpeCausero Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.8.1.2 |
connLoopOpeModeF4 (VP level)/f5 (VC level).rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.8.1.3 |
connLoopOpeBaserw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.8.1.4 |
connLoopOpeLoopBackPointNodeIdrw OCTET STRING ( SIZE (16) ) .1.3.6.1.4.1.119.2.3.14.9.4.8.1.5 |
connLoopOpeCorrelationTagrw OCTET STRING ( SIZE (4) ) .1.3.6.1.4.1.119.2.3.14.9.4.8.1.6 |
connLoopOpeCountrw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.8.1.7 |
connLoopOpePortrw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.8.1.8 |
connLoopOpeVpirw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.8.1.9 |
connLoopOpeVcirw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.8.1.10 |
connLoopOpeNormalEndCountro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.8.1.11 |
connLoopOpeAbnormalEndCountro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.8.1.12 |
connLoopOpeAbortCountro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.8.1.13 |
connLoopOpeLoopBackPointIdLengthrw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.8.1.14 |
connProfile OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.4.9 |
connProfileIndexNextShows the empty index value of connProfileTable(including
row of notReady, notInService).
If the number of profiles reaches the registration limit, 0.ro ConnProfileIndex .1.3.6.1.4.1.119.2.3.14.9.4.9.1 |
connProfileTableTable to set/indicate the profile. SEQUENCE OF ConnProfileEntry .1.3.6.1.4.1.119.2.3.14.9.4.9.2 |
connProfileEntryEntry of connProfileTable. ConnProfileEntry .1.3.6.1.4.1.119.2.3.14.9.4.9.2.1 |
connProfileIndexIndex value of connProfileTable. ConnProfileIndex .1.3.6.1.4.1.119.2.3.14.9.4.9.2.1.1 |
connProfileRowStatusUsed to control rows of the table.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.9.2.1.2 |
connProfileCauseThe result of Profile setting processing.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.9.2.1.3 |
connProfileTrafficTypeTraffic Type.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.9.2.1.4 |
connProfileNameProfile name.
Available characters: alphanumeric characters
0 length string is only read.rw DisplayString .1.3.6.1.4.1.119.2.3.14.9.4.9.2.1.5 |
connProfileParam1For ph1/2-buffer, peek cell rate [cell/sec].
If it is invalid, -1.rw INTEGER (-1|1..1412830) .1.3.6.1.4.1.119.2.3.14.9.4.9.2.1.6 |
connProfileParam2For ph1/2-buffer, Sustainable cell rate [cell/sec].
Only nrt-VBR, and rt-VBR are valid.
If it is invalid, -1.rw INTEGER (-1|1..1412830) .1.3.6.1.4.1.119.2.3.14.9.4.9.2.1.7 |
connProfileParam3For ph1/2-buffer, Maximum burst size [cell].
Only nrt-VBR, and rt-VBR are valid.
If it is invalid, -1.rw INTEGER (-1|1..1412830) .1.3.6.1.4.1.119.2.3.14.9.4.9.2.1.8 |
connProfileParam4For ph1/2-buffer, EPD function flag.
If it is other than ABR, UBR, off, only.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.9.2.1.9 |
connProfileName2IndexEquivalent to connProfileNamerw DisplayString .1.3.6.1.4.1.119.2.3.14.9.4.9.3 |
connProfileName2IndexResultShows the index of the row whose connProfileRowStatus in
connProfileTable, corresponding to connProfileName2Index,
is active. If the corresponding row does not exist, 0.ro ConnProfileIndex .1.3.6.1.4.1.119.2.3.14.9.4.9.4 |
connSvcTable SEQUENCE OF ConnSvcEntry .1.3.6.1.4.1.119.2.3.14.9.4.10 |
connSvcEntry ConnSvcEntry .1.3.6.1.4.1.119.2.3.14.9.4.10.1 |
connSvcIndex INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.10.1.1 |
connSvcInfro Opaque .1.3.6.1.4.1.119.2.3.14.9.4.10.1.2 |
connCe OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.4.11 |
connCeVc OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.4.11.1 |
connCeVcTable SEQUENCE OF ConnCeVcEntry .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1 |
connCeVcEntry ConnCeVcEntry .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1 |
connCeVcPortLine number. INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.1 |
connCeVcVciVCI value. INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.2 |
connCeVcRowStatusUsed to control rows of the table.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.3 |
connCeVcCauseThe result of CEVC setting processing.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.4 |
connCeVcDirectionrw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.5 |
connCeVcUpPartialFillSizerw INTEGER (-1|0..47) -- default -1 .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.6 |
connCeVcDownPartialFillSizerw INTEGER (-1|0..47) -- default -1 .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.7 |
connCeVcConditionCondtion date.rw INTEGER (-1|0..255) -- default -1 .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.8 |
connCeVcCDVTCDVT value.
+++
|pkg type| str mode |CDVT range| unit of |
| | | | setting |
================================================
| CE-J2 | unstructure | 1..73 | 125sec |
| +-+
| | structure | 1..7218 | 125sec |
++-+
| CE-DS1 | unstructure | 1..255 | 165.8sec |
| +-+
| | structure | 1..191 | 125sec |
++-+
| CE-E1 | unstructure | 1..255 | 124.5sec |
| +-+
| | structure | 1..255 | 125sec |
++-+
| CE-DS3 | unstructure | 1..255 | 5.7sec |
++-+rw INTEGER (-1|1..7218) -- default -1 .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.9 |
connCeVcUpPCRro INTEGER (-1|0..118979) -- default -1 .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.10 |
connCeVcDownPCRro INTEGER (-1|0..118979) -- .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.11 |
connCeVcUpTimeSlot1rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.12 |
connCeVcDownTimeSlot1rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.13 |
connCeVcUpTimeSlot2rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.14 |
connCeVcDownTimeSlot2rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.15 |
connCeVcUpTimeSlot3rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.16 |
connCeVcDownTimeSlot3rw INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.11.1.1.1.17 |
connFr OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.4.12 |
connFrDlci OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.4.12.1 |
connFrDlciTable SEQUENCE OF ConnFrDlciEntry .1.3.6.1.4.1.119.2.3.14.9.4.12.1.1 |
connFrDlciEntryEntry of connFrDlciTable. ConnFrDlciEntry .1.3.6.1.4.1.119.2.3.14.9.4.12.1.1.1 |
connFrDlciPortLine number. INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.12.1.1.1.1 |
connFrDlciIndexDLCI number. INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.12.1.1.1.2 |
connFrDlciRowStatusUsed to control rows of the table.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.12.1.1.1.3 |
connFrDlciCausero Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.12.1.1.1.4 |
connFrDlciFrProfilerw DisplayString .1.3.6.1.4.1.119.2.3.14.9.4.12.1.1.1.5 |
connFrDlciPCRPeak Cell Rate[cell/sec].ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.12.1.1.1.6 |
connFrDlciSCRSustainable Cell Rate[cell/sec].ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.12.1.1.1.7 |
connFrDlciMBSMaximum Burst Size[cell].ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.4.12.1.1.1.8 |
connFrProfile OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.4.12.2 |
connFrProfileIndexNextro ConnFrProfileIndex .1.3.6.1.4.1.119.2.3.14.9.4.12.2.1 |
connFrProfileTable SEQUENCE OF ConnFrProfileEntry .1.3.6.1.4.1.119.2.3.14.9.4.12.2.2 |
connFrProfileEntryEntry of connFrProfileTable. ConnFrProfileEntry .1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1 |
connFrProfileIndexIndex of connFrProfileTable. ConnFrProfileIndex .1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.1 |
connFrProfileRowStatusUsed to control rows of the table.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.2 |
connFrProfileCauseThe result of Frprofile setting processing.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.3 |
connFrProfileNameFrprofile name.
Available characters: alphanumeric characters
0 length string is only read.rw DisplayString .1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.4 |
connFrProfileInterworkingTypeInterworking Typerw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.5 |
connFrProfileCIRCIR value.rw INTEGER (-1|1..1984) -- .1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.6 |
connFrProfileDEtoCLPDE to CLP mapping moderw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.7 |
connFrProfileCLPValueCLP Value.
It's valid when connFrProfileDEtoCLP is mode2.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.8 |
connFrProfileCLPtoDECLP to DE mapping mode.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.9 |
connFrProfileDEValueDE Value.
It's valid when connFrProfileInterworkingType is service
and connFrProfileCLPtoDE is mode2.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.10 |
connFrProfileCapsulationModeProtocol encapsulation mode.
It's valid when connFrProfileInterworkingType is service.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.11 |
connFrProfileCongestionModeCongestion indication(Forward) mode.
It's valid when connFrProfileInterworkingType is service.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.4.12.2.2.1.12 |
connFrProfileName2IndexEquivalent to connProfileName.rw DisplayString .1.3.6.1.4.1.119.2.3.14.9.4.12.2.3 |
connFrProfileName2IndexResultShows the index of the row whose connFrProfileRowStatus in
connFrProfileTable, corresponding to connFrProfileName2Index,
is active. If the corresponding row does not exist, 0.ro ConnFrProfileIndex .1.3.6.1.4.1.119.2.3.14.9.4.12.2.4 |
perf OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.5 |
perfTrapEnableThis object is used for disabling/enabling trap messages
regarding the enterprise specific traps.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.5.1 |
perfIfTableTable for showing the result of the performance monitoring
per line of the equipment. Up to 64 tables are available for
entry.
Every line whose traffic is managed per line is provided with
an entry. SEQUENCE OF PerfIfEntry .1.3.6.1.4.1.119.2.3.14.9.5.2 |
perfIfEntryEntry of the line performance monitoring. PerfIfEntry .1.3.6.1.4.1.119.2.3.14.9.5.2.1 |
perfIfIndexLine number. INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.2.1.1 |
perfIfReceivedCellsThe Number of the receive cells of line port.
(64 bit applicable)ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.2.1.2 |
perfIfReceivedCellsCountersThe Number of the receive cells of line port.
(32 bit applicable).ro Counter .1.3.6.1.4.1.119.2.3.14.9.5.2.1.3 |
perfIfTransmittedCellsThe Number of the transmit cells of line port.
(64 bit applicable).ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.2.1.4 |
perfIfTransmittedCellsCountersThe Number of the transmit cells of line port.
(32 bit applicable).ro Counter .1.3.6.1.4.1.119.2.3.14.9.5.2.1.5 |
perfIfMisDelivdCellsThe Number of the undefined cells of line port.
(64 bit applicable).ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.2.1.8 |
perfIfMisDelivdCellsCountersThe Number of the undefined cells of line port.
(32 bit applicable).ro Counter .1.3.6.1.4.1.119.2.3.14.9.5.2.1.9 |
perfIfThresholdExcessCellsNumber of the threshold excess cells (64 bit applicable).ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.2.1.10 |
perfIfThresholdExcessCellsCountersNumber of the threshold excess cells (32 bit applicable).ro Counter .1.3.6.1.4.1.119.2.3.14.9.5.2.1.11 |
perfIfUpcErrorCellsNumber of the UPC error cells (64 bit applicable).ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.2.1.12 |
perfIfUpcErrorCellsCountersNumber of the UPC error cells (32 bit applicable).ro Counter .1.3.6.1.4.1.119.2.3.14.9.5.2.1.13 |
perfIfSlotTableTable for showing the number of cells of the traffic and
performance per line card of the equipment.
Up to 16 tables are available for entry.
Every line whose traffic is managed per slot is provided
with an entry.
The object which becomes invalid by the line card is always 0. SEQUENCE OF PerfIfSlotEntry .1.3.6.1.4.1.119.2.3.14.9.5.3 |
perfIfSlotEntryEntry of traffic/performance per line card. PerfIfSlotEntry .1.3.6.1.4.1.119.2.3.14.9.5.3.1 |
perfIfSlotReceivedCellsThe number of receive cells.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.3.1.1 |
perfIfSlotTransmittedCellsThe number of transmit cells.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.3.1.2 |
perfIfSlotInDropCellsThe number of receive drop cells.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.3.1.3 |
perfIfSlotReceivedCellsCountersThe number of receive cells.ro Counter .1.3.6.1.4.1.119.2.3.14.9.5.3.1.5 |
perfIfSlotTransmittedCellsCountersThe number of transmit cells.ro Counter .1.3.6.1.4.1.119.2.3.14.9.5.3.1.6 |
perfIfSlotInDropCellsCountersThe number of receive drop cells.ro Counter .1.3.6.1.4.1.119.2.3.14.9.5.3.1.7 |
perfIfSlotHCThresholdExcessCellsThe number of threshold excess cellsro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.3.1.9 |
perfIfSlotThresholdExcessCellsThe number of threshold excess cellsro Counter .1.3.6.1.4.1.119.2.3.14.9.5.3.1.10 |
perfIfSlotHCUpcErrorCellsNumber of UPC error cells.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.3.1.11 |
perfIfSlotUpcErrorCellsNumber of UPC error cells.ro Counter .1.3.6.1.4.1.119.2.3.14.9.5.3.1.12 |
perfIfPhysTable SEQUENCE OF PerfIfPhysEntry .1.3.6.1.4.1.119.2.3.14.9.5.4 |
perfIfPhysEntry PerfIfPhysEntry .1.3.6.1.4.1.119.2.3.14.9.5.4.1 |
perfIfPhysPortLine number. INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.1 |
perfIfPhysHCHecErorrsNumber of HEC error cells(64 bit applicable).
On the line card other than OC12, J2 and PR-1.5M,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.2 |
perfIfPhysHecErorrsNumber of HEC error cells(32 bit applicable).
On the line card other than OC12, J2 and PR-1.5M,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.3 |
perfIfPhysHCHecDropCellsNumber of uncorrectable HEC error cells(64 bit applicable).
On the line card other than OC3, OC12, OC12PMC, J2,
PR-1.5, DS3, E3, DS1 and E1, the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.4 |
perfIfPhysHecDropCellsNumber of uncorrectable HEC error cells(32 bit applicable).
On the line card other than OC3, OC12, OC12PMC, J2,
PR-1.5, DS3, E3, DS1 and E1, the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.5 |
perfIfPhysHCB1ErrorsNumber of B1 errors(64 bit applicable).
On the line card other than OC3, OC12, OC12PMC,
DS3, E3, DS1 and E1,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.6 |
perfIfPhysB1ErrorsNumber of B1 errors(32 bit applicable).
On the line card other than OC3, OC12, OC12PMC,
DS3, E3, DS1 and E1,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.7 |
perfIfPhysHCB2ErrorsNumber of B2 errors(64 bit applicable).
On the line card other than OC3, OC12 and OC12PMC,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.8 |
perfIfPhysB2ErrorsNumber of B2 errors(32 bit applicable).
On the line card other than OC3, OC12 and OC12PMC,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.9 |
perfIfPhysHCB3ErrorsNumber of B3 errors(64 bit applicable).
On the line card other than OC3, OC12 and OC12PMC,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.10 |
perfIfPhysB3ErrorsNumber of B3 errors(32 bit applicable).
On the line card other than OC3, OC12 and OC12PMC,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.11 |
perfIfPhysHCPathFEBEsNumber of Path FEBEs(64 bit applicable).
On the line card other than OC3, OC12 and OC12PMC,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.12 |
perfIfPhysPathFEBEsNumber of Path FEBEs(32 bit applicable).
On the line card other than OC3, OC12 and OC12PMC,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.13 |
perfIfPhysHCLineFEBEsNumber of Line (Section) FEBEs(64 bit applicable).
On the line card other than OC3, OC12 and OC12PMC,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.14 |
perfIfPhysLineFEBEsNumber of Line (Section) FEBEs(32 bit applicable).
On the line card other than OC3, OC12 and OC12PMC,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.15 |
perfIfPhysHCFramingErrorsNumber of Framing errors(64 bit applicable).
On the line card other than DS1, E1, DS3 and E3,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.16 |
perfIfPhysFramingErrorsNumber of Framing errors(32 bit applicable).
On the line card other than DS1, E1, DS3 and E3,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.17 |
perfIfPhysHCReceivedCellsThe Number of the receive cells(64 bit applicable).
On the line card other than DS3, E3 and OC12PMC,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.18 |
perfIfPhysReceivedCellsThe Number of the receive cells(32 bit applicable).
On the line card other than DS3, E3 and OC12PMC,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.19 |
perfIfPhysHCTransmittedCellsThe Number of the transmit cells(64 bit applicable).
On the line card other than DS3, E3 and OC12PMC,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.20 |
perfIfPhysTransmittedCellsThe Number of the transmit cells(32 bit applicable).
On the line card other than DS3, E3 and OC12PMC,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.21 |
perfIfPhysHCIdelUnassignedCellsThe Number of Idle/Unassigned cells(64 bit applicable).
On the line card other than DS3 and E3,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.22 |
perfIfPhysIdelUnassignedCellsThe Number of Idle/Unassigned cells(32 bit applicable).
On the line card other than DS3 and E3,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.23 |
perfIfPhysHCFEBEErrorsNumber of FEBE errors(64 bit applicable).
On the line card other than DS3, E3, DS1 and E1,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.24 |
perfIfPhysFEBEErrorsNumber of FEBEs errors(32 bit applicable).
On the line card other than DS3, E3, DS1 and E1,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.25 |
perfIfPhysHCFEBEsNumber of FEBEs(64 bit applicable).
On the line card other than DS3, E3, E1 and CE-E1,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.26 |
perfIfPhysFEBEsNumber of FEBEs(32 bit applicable).
On the line card other than DS3, E3, E1 and CE-E1,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.27 |
perfIfPhysHCPathParityErrorsNumber of path parity errors(64 bit applicable).
On the line card other than DS3,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.28 |
perfIfPhysPathParityErrorsNumber of path parity errors(32 bit applicable).
On the line card other than DS3,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.29 |
perfIfPhysHCParityErrorsNumber of parity errors(64 bit applicable).
On the line card other than DS3,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.30 |
perfIfPhysParityErrorsNumber of parity errors(32 bit applicable).
On the line card other than DS3,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.31 |
perfIfPhysHCSEZsNumber of detections of Summed excessive Zero
(64 bit applicable).
On the line card other than DS3,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.32 |
perfIfPhysSEZsNumber of detections of Summed excessive Zero
(32 bit applicable).
On the line card other than DS3,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.33 |
perfIfPhysHCBitErrorsNumber of Bit errors(64 bit applicable).
On the line card other than DS3 and CE-DS1(SF mode),
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.34 |
perfIfPhysBitErrorsNumber of Bit errors(32 bit applicable).
On the line card other than DS3 and CE-DS1(SF mode),
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.35 |
perfIfPhysHCLcvErrorsNumber of LCV errors(64 bit applicable).
On the line card other than DS3, E3, DS1, E1,
FR-E1, CE-DS1, FR-DS1 and CE-E1,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.36 |
perfIfPhysLcvErrorsNumber of LCV errors(32 bit applicable).
On the line card other than DS3, E3, DS1, E1,
FR-E1, CE-DS1, FR-DS1 and CE-E1,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.37 |
perfIfPhysHCBip8ErrorsNumber of BIP-8 errors(64 bit applicable).
On the line card other than E3,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.38 |
perfIfPhysBip8ErrorsNumber of BIP-8 errors(32 bit applicable).
On the line card other than E3,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.39 |
perfIfPhysHCIecErrorsNumber of IEC errors(64 bit applicable).
On the line card other than E3,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.40 |
perfIfPhysIecErrorsNumber of IEC errors(32 bit applicable).
On the line card other than E3,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.41 |
perfIfPhysHCFramingPatternErrorsNumber of Framing pattern errors(64 bit applicable).
On the line card other than E3,
the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.42 |
perfIfPhysFramingPatternErrorsNumber of Framing pattern errors(32 bit applicable).
On the line card other than E3,
the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.43 |
perfIfPhysHCFramingBitErrorsNumber of Framing bit errors(64 bit applicable).
On the line card other than DS1, E1, FR-E1, CE-DS1, FR-DS1
and CE-E1, the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.44 |
perfIfPhysFramingBitErrorsNumber of Framing bit errors(32 bit applicable).
On the line card other than DS1, E1, FR-E1, CE-DS1, FR-DS1
and CE-E1, the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.45 |
perfIfPhysHCCrcErrorsNumber of CRC errors(64 bit applicable).
On the line card other than DS1, E1, FR-E1, FR-DS1,
CE-DS1(ESF mode) and CE-E1, the value of this object is 0.ro OCTET STRING .1.3.6.1.4.1.119.2.3.14.9.5.4.1.46 |
perfIfPhysCrcErrorsNumber of CRC errors(32 bit applicable).
On the line card other than DS1, E1, FR-E1, FR-DS1,
CE-DS1(ESF mode) and CE-E1, the value of this object is 0.ro INTEGER .1.3.6.1.4.1.119.2.3.14.9.5.4.1.47 |
scale OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.6 |
scaleStatusOrder to execute and state.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.6.1 |
scaleCauseThe result of execution.ro Enumeration .1.3.6.1.4.1.119.2.3.14.9.6.2 |
scaleDataTypeData type.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.6.3 |
scaleTargetIP address of the target.rw IpAddress .1.3.6.1.4.1.119.2.3.14.9.6.4 |
scaleFileNameFile name(up to 127 characters).rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.119.2.3.14.9.6.5 |
scaleSwSideIndicate which system of the SW-Engine.rw Enumeration .1.3.6.1.4.1.119.2.3.14.9.6.6 |
card OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.7 |
cardStatusTableTable showing the configuration information of the line
card with CPU. SEQUENCE OF CardStatusEntry .1.3.6.1.4.1.119.2.3.14.9.7.1 |
cardStatusEntryEntry of the configuration nformation of the line card
with CPU. CardStatusEntry .1.3.6.1.4.1.119.2.3.14.9.7.1.1 |
clock OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.8 |
diag OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.9 |
pnni OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.10 |
matCmd OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.9.11 |
cardStatusServerTypeIndicate the types of the server installed in
the line card with CPU:
other (1) ...other than the below stated types
LANE (2)
ARP (4)
NHRP (8)
MPOA (16)
If more than one server type is installed, return the sum
of their values.
e.g.
Only NHRP is installed
ARP and NHRP are installed
LANE, ARP and NHRP are installed
::= { cardStatusEntry 1 }
cardStatusRevision OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTIONro INTEGER .1.3.6.1.4.1.119.2.3.14.9.11.6 |
m7-corporate-mib OBJECT IDENTIFIER .1.3.6.1.4.1.119.2.3.14.12 |