This MIB is to be used to provide monitoring information support for Lenovo XClarity Controller (XCC)
Main OID:
lenovoXCCMIB.1.3.6.1.4.1.19046.11.1
893
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

893 total
Object Name
lenovoXCCMIBThis MIB is to be used to provide monitoring information support for Lenovo XClarity Controller (XCC)
MODULE-IDENTITY
.1.3.6.1.4.1.19046.11.1
IMPORTSThis MIB is to be used to provide monitoring information support for Lenovo XClarity Controller (XCC)
Unknown
.1.3.6.1.4.1.19046.11.1
monitors
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1
temperature
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.1
tempNumberThe present number of rows in the temperature table.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.1.1
tempTableThis table contains temperature measurement information.
SEQUENCE OF TempEntry
.1.3.6.1.4.1.19046.11.1.1.1.2
tempEntryEach row contains parameters related to a temperature measurement channel.
TempEntry
.1.3.6.1.4.1.19046.11.1.1.1.2.1
tempIndexThis column is used to identify a particular temperature measurement channel.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.1.2.1.1
tempDescrA description of the temperature measurement channel.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.1.2.1.2
tempReadingThe measured temperature.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.1.2.1.3
tempNominalReadingThe nominal temperature, if available.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.1.2.1.4
tempNonRecovLimitHighThe non-recoverable limit for the measured temperature. If the measured value rises above this limit a trap is sent.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.1.2.1.5
tempCritLimitHighThe critical limit for the measured temperature. If the measured value rises above this limit a trap is sent.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.1.2.1.6
tempNonCritLimitHighThe non-critical limit for the measured temperature. If the measured value rises above this limit a trap is sent.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.1.2.1.7
tempNonRecovLimitLowThe non-recoverable limit for the measured temperature. If the measured value falls below this limit a trap is sent.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.1.2.1.8
tempCritLimitLowThe critical limit for the measured temperature. If the measured value falls below this limit a trap is sent.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.1.2.1.9
tempNonCritLimitLowThe non-critical limit for the measured temperature. If the measured value falls below this limit a trap is sent.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.1.2.1.10
tempHealthStatusA description of the temperature component status.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.1.2.1.11
voltage
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.2
voltNumberThe present number of rows in the voltage table.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.2.1
voltTableThis table contains voltage measurement information.
SEQUENCE OF VoltEntry
.1.3.6.1.4.1.19046.11.1.1.2.2
voltEntryEach row contains parameters related to a voltage measurement channel.
VoltEntry
.1.3.6.1.4.1.19046.11.1.1.2.2.1
voltIndexThis column is used to identify a particular voltage measurement channel.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.2.2.1.1
voltDescrA description of the voltage measurement channel.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.2.2.1.2
voltReadingThe measured voltage.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.2.2.1.3
voltNominalReadingThe nominal voltage, if available.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.2.2.1.4
voltNonRecovLimitHighThe high non-recoverable limit for the measured voltage. If the measured value falls above this limit a trap is sent.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.2.2.1.5
voltCritLimitHighThe high critical limit for the measured voltage. If the measured value rises above this limit a trap is sent.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.2.2.1.6
voltNonCritLimitHighThe high non-critical limit for the measured voltage. If the measured value rises above this limit a trap is sent.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.2.2.1.7
voltNonRecovLimitLowThe low non-recoverable limit for the measured voltage. If the measured value falls below this limit a trap is sent.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.2.2.1.8
voltCritLimitLowThe low critical limit for the measured voltage. If the measured value falls below this limit a trap is sent.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.2.2.1.9
voltNonCritLimitLowThe low non-critical limit for the measured voltage. If the measured value falls below this limit a trap is sent.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.2.2.1.10
voltHealthStatusA description of the voltage component status.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.2.2.1.11
fans
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.3
fanNumberThe present number of rows in the fan table.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.3.1
fanTableThis table contains fan information.
SEQUENCE OF FanEntry
.1.3.6.1.4.1.19046.11.1.1.3.2
fanEntryEach row contains parameters related to a fan.
FanEntry
.1.3.6.1.4.1.19046.11.1.1.3.2.1
fanIndexThis column is used to identify a particular fan.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.3.2.1.1
fanDescrA description of the fan measurement channel.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.3.2.1.2
fanSpeedFan speed expressed in percent(%) of maximum RPM. An octet string expressed as 'ddd% of maximum' where: d is a decimal digit or blank space for a leading zero. If the fan is determined not to be running or the fan speed cannot be determined, the string will indicate 'Offline'.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.3.2.1.3
fanNonRecovLimitHighThe high non-recoverable limit for the measured fan. If the measured value falls above this limit a trap is sent.ro
Gauge UNITS "RPM"
.1.3.6.1.4.1.19046.11.1.1.3.2.1.4
fanCritLimitHighThe high critical limit for the measured fan. If the measured value rises above this limit a trap is sent.ro
Gauge UNITS "RPM"
.1.3.6.1.4.1.19046.11.1.1.3.2.1.5
fanNonCritLimitHighThe high non-critical limit for the measured fan. If the measured value rises above this limit a trap is sent.ro
Gauge UNITS "RPM"
.1.3.6.1.4.1.19046.11.1.1.3.2.1.6
fanNonRecovLimitLowThe low non-recoverable limit for the measured fan. If the measured value falls below this limit a trap is sent.ro
Gauge UNITS "RPM"
.1.3.6.1.4.1.19046.11.1.1.3.2.1.7
fanCritLimitLowThe low critical limit for the measured fan. If the measured value falls below this limit a trap is sent.ro
Gauge UNITS "RPM"
.1.3.6.1.4.1.19046.11.1.1.3.2.1.8
fanNonCritLimitLowThe low non-critical limit for the measured fan. If the measured value falls below this limit a trap is sent.ro
Gauge UNITS "RPM"
.1.3.6.1.4.1.19046.11.1.1.3.2.1.9
fanHealthStatusA description of the fan component status.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.3.2.1.10
systemHealth
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.4
systemHealthStatIndicates status of system health for the system in which the XCC resides. Value of 'nonRecoverable' indicates a severe error has occurred and the system may not be functioning. A value of 'critical' indicates that a error has occurred but the system is currently functioning properly. A value of 'nonCritical' indicates that a condition has occurred that may change the state of the system in the future but currently the system is working properly. A value of 'normal' indicates that the system is operating normally.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.1.4.1
systemHealthSummaryTableTable of System Health summary. Contains more detailed information about the reasons for the overall system health status.
SEQUENCE OF SystemHealthSummaryEntry
.1.3.6.1.4.1.19046.11.1.1.4.2
systemHealthSummaryEntrySystem Health Summary entry
SystemHealthSummaryEntry
.1.3.6.1.4.1.19046.11.1.1.4.2.1
systemHealthSummaryIndexSystem health summary index.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.4.2.1.1
systemHealthSummarySeveritySystem health summary severity.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.4.2.1.2
systemHealthSummaryDescriptionSystem health summary description.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.4.2.1.3
vpdInformation
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.5
xccVpdTableTable of XCC VPD.
SEQUENCE OF XCCVpdEntry
.1.3.6.1.4.1.19046.11.1.1.5.1
xccVpdEntryiMBC VPD entry.
XCCVpdEntry
.1.3.6.1.4.1.19046.11.1.1.5.1.1
xccVpdIndexXCC VPD index.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.5.1.1.1
xccVpdTypeXCC VPD Type. Indicates either Bios or Diag or spFimware VPDro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.5.1.1.2
xccVpdVersionStringXCC VPD Version Number of the software(Bios/Diag/spFirmware). For XCC the string contains both the Build ID and the Version Number, for example, like '1AOO3A v1.0.1'.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.5.1.1.3
xccVpdReleaseDateXCC VPD Release Date of when the software(Bios/Diag/spFirmware) was released.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.5.1.1.4
machineVpd
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.5.2
machineLevelVpd
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.5.2.1
machineLevelVpdMachineTypeMachine type VPD information.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.5.2.1.1
machineLevelVpdMachineModelMachine model VPD information.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.5.2.1.2
machineLevelSerialNumberMachine serial number VPD information.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.5.2.1.3
machineLevelUUIDMachine UUID(Universal Unique ID information).ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.5.2.1.4
machineLevelProductNameMachine Product Name (e.g. System x3650 M2).ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.5.2.1.5
systemComponentLevelVpdTableTable of the system component hardware VPD information. View as a table and not as individual entries for consistent results.
SEQUENCE OF SystemComponentLevelVpdEntry
.1.3.6.1.4.1.19046.11.1.1.5.17
systemComponentLevelVpdEntrySystem component hardware VPD entry. View as a table and not as individual entries for consistent results.
SystemComponentLevelVpdEntry
.1.3.6.1.4.1.19046.11.1.1.5.17.1
componentLevelVpdIndexSystem component level VPD index. View as a table and not as individual entries for consistent results.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.5.17.1.1
componentLevelVpdFruNumberSystem component level VPD FRU number. View as a table and not as individual entries for consistent results.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.5.17.1.2
componentLevelVpdFruNameSystem component level VPD FRU name. View as a table and not as individual entries for consistent results.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.5.17.1.3
componentLevelVpdSerialNumberSystem component level VPD serial number. View as a table and not as individual entries for consistent results.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.5.17.1.4
componentLevelVpdManufacturingIdSystem component level VPD manufacturing ID. View as a table and not as individual entries for consistent results.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.5.17.1.5
systemComponentLevelVpdTrackingTableTable of system component hardware VPD tracking activity log. View as a table and not as individual entries for consistent results.
SEQUENCE OF SystemComponentLevelVpdTrackingEntry
.1.3.6.1.4.1.19046.11.1.1.5.18
systemComponentLevelVpdTrackingEntrySystem component hardware VPD tracking activity log entry. View as a table and not as individual entries for consistent results.
SystemComponentLevelVpdTrackingEntry
.1.3.6.1.4.1.19046.11.1.1.5.18.1
componentLevelVpdTrackingIndexSystem component level VPD tracking activity log index. View as a table and not as individual entries for consistent results.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.5.18.1.1
componentLevelVpdTrackingFruNumberSystem component level VPD tracking activity log FRU number. View as a table and not as individual entries for consistent results.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.5.18.1.2
componentLevelVpdTrackingFruNameSystem component level VPD tracking activity log FRU name. View as a table and not as individual entries for consistent results.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.5.18.1.3
componentLevelVpdTrackingSerialNumberSystem component level VPD tracking activity log serial number. View as a table and not as individual entries for consistent results.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.5.18.1.4
componentLevelVpdTrackingManufacturingIdSystem component level VPD tracking activity log manufacturing ID. View as a table and not as individual entries for consistent results.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.5.18.1.5
componentLevelVpdTrackingActionSystem component level VPD tracking activity log action(added/removed). View as a table and not as individual entries for consistent results.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.5.18.1.6
componentLevelVpdTrackingTimestampSystem component level VPD tracking activity log timestanp. View as a table and not as individual entries for consistent results.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.5.18.1.7
hostMACAddressTableTable of MAC addresses of the host NICs. For consistent results, view as a table and not as individual entries.
SEQUENCE OF HostMACAddressEntry
.1.3.6.1.4.1.19046.11.1.1.5.19
hostMACAddressEntryHost MAC address entry. For consistent results, view as a table and not as individual entries.
HostMACAddressEntry
.1.3.6.1.4.1.19046.11.1.1.5.19.1
hostMACAddressIndexHost MAC address index. View as a table and not as individual entries for consistent results.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.5.19.1.1
hostMACAddressDescriptionDescription of the MAC Address entry. View as a table and not as individual entries for consistent results.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.5.19.1.2
hostMACAddressHost MAC address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX View as a table and not as individual entries for consistent results.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.5.19.1.3
systemCPUVpdTableTable of the system CPU VPD information. View as a table and not as individual entries for consistent results.
SEQUENCE OF SystemCPUVpdEntry
.1.3.6.1.4.1.19046.11.1.1.5.20
systemCPUVpdEntrySystem CPU VPD entry. View as a table and not as individual entries for consistent results.
SystemCPUVpdEntry
.1.3.6.1.4.1.19046.11.1.1.5.20.1
cpuVpdIndexSystem CPU level VPD index. View as a table and not as individual entries for consistent results.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.5.20.1.1
cpuVpdDescriptionSystem CPU Description. View as a table and not as individual entries for consistent results.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.5.20.1.2
cpuVpdSpeedSystem cpu speed in MHz. View as a table and not as individual entries for consistent results.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.5.20.1.3
cpuVpdIdentifierSystem CPU Identifier. View as a table and not as individual entries for consistent results.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.5.20.1.4
cpuVpdTypeSystem cpu Type. View as a table and not as individual entries for consistent results.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.5.20.1.5
cpuVpdFamilySystem cpu Family. View as a table and not as individual entries for consistent results.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.5.20.1.6
cpuVpdCoresSystem cpu number of cores. View as a table and not as individual entries for consistent results.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.5.20.1.7
cpuVpdThreadsSystem cpu number of threads. View as a table and not as individual entries for consistent results.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.5.20.1.8
cpuVpdVoltageSystem cpu voltage in millivolts (1125 = 1.125 volts). View as a table and not as individual entries for consistent results.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.5.20.1.9
cpuVpdDataWidthSystem cpu data width in bits. View as a table and not as individual entries for consistent results.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.5.20.1.10
cpuVpdHealthStatusSystem cpu health status. View as a table and not as individual entries for consistent results.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.5.20.1.11
cpuVpdCpuModelSystem cpu model. View as a table and not as individual entries for consistent results.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.5.20.1.12
systemMemoryVpdTableTable of the system Memory VPD information. View as a table and not as individual entries for consistent results.
SEQUENCE OF SystemMemoryVpdEntry
.1.3.6.1.4.1.19046.11.1.1.5.21
systemMemoryVpdEntrySystem Memory VPD entry. View as a table and not as individual entries for consistent results.
SystemMemoryVpdEntry
.1.3.6.1.4.1.19046.11.1.1.5.21.1
memoryVpdIndexSystem Memory level VPD index. View as a table and not as individual entries for consistent results.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.5.21.1.1
memoryVpdDescriptionSystem memory Description (e.g. DIMM 1). View as a table and not as individual entries for consistent results.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.5.21.1.2
memoryVpdPartNumberSystem Memory Part Number. View as a table and not as individual entries for consistent results.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.5.21.1.3
memoryVpdFRUSerialNumberSystem memory Serial Number. View as a table and not as individual entries for consistent results.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.5.21.1.4
memoryVpdManufactureDateSystem memory Manufacture Date in week/year format (e.g. 3609). View as a table and not as individual entries for consistent results.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.5.21.1.5
memoryVpdTypeSystem memory Type (e.g. DDR III SDRAM). View as a table and not as individual entries for consistent results.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.5.21.1.6
memoryVpdSizeSystem memory size in GigaBytes. View as a table and not as individual entries for consistent results.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.5.21.1.7
memoryHealthStatusA description of the memory component status.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.5.21.1.8
memoryConfigSpeedSystem configured memory clock speed in MHz. View as a table and not as individual entries for consistent results.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.5.21.1.9
memoryRatedSpeedSystem rated memory clock speed in MB/s. View as a table and not as individual entries for consistent results.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.5.21.1.10
memoryLenovoPartNumberSystem Memory Lenovo related Part Number. View as a table and not as individual entries for consistent results.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.5.21.1.11
users
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.6
xccUsers
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.6.1
currentlyLoggedInTableTable of XCC users currently logged in.
SEQUENCE OF CurrentlyLoggedInEntry
.1.3.6.1.4.1.19046.11.1.1.6.1.1
currentlyLoggedInEntryXCC users currently logged in entries.
CurrentlyLoggedInEntry
.1.3.6.1.4.1.19046.11.1.1.6.1.1.1
currentlyLoggedInEntryIndexIndex for XCC users currently logged in.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.6.1.1.1.1
currentlyLoggedInEntryUserIdName for XCC users currently logged in.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.6.1.1.1.2
currentlyLoggedInEntryAccMethodAccess method for XCC users currently logged in.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.6.1.1.1.3
leds
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.8
identityLEDIndicates whether the front panel identity LED is on,off, or blinking and allows user to change it.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.1.8.1
allLEDsTableTable of LEDs detailed information.
SEQUENCE OF AllLEDsEntry
.1.3.6.1.4.1.19046.11.1.1.8.2
allLEDsEntryLEDs Details entry
AllLEDsEntry
.1.3.6.1.4.1.19046.11.1.1.8.2.1
ledIndexThe LED index number. For consistent results, view as a table and not as individual entries.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.8.2.1.1
ledIdentifierThe unique identifier for this LED For consistent results, view as a table and not as individual entries.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.8.2.1.2
ledLabelText label for a LED. For consistent results, view as a table and not as individual entries.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.8.2.1.4
ledStateText description which denotes color or on/off/blink state for a LED. For consistent results, view as a table and not as individual entries.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.1.8.2.1.5
ledColorColor of this LED. For consistent results, view as a table and not as individual entries.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.8.2.1.6
informationLEDIndicates whether the front panel Information LED is on,off, or blinking and allows user to change it. The only value the user is allowed to enter is 0 for off. User may not turn this LED on or cause it to blink.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.1.8.3
fuelGauge
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.10
fuelGaugeInformation
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.10.1
fuelGaugePowerCappingPolicySettingPower Capping Policy. Rack system only. No Power Limit - The maximum power limit will be determined by the active Power Redundancy policy. Static Power Limit - Sets the overall system power limit. In a situation where powering on a component would cause the limit to be exceeded, the component would not be permitted to power on.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.1.10.1.1
fuelGaugeStaticPowerPcapSoftMinThis field displays power capping soft minimum value. Rack system only.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.1.2
fuelGaugeStaticPowerPcapMinThis field displays power capping minimum value. Rack system only.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.1.3
fuelGaugeStaticPowerPcapCurrentSettingThis field is used to display or set the current power capping value. Rack system only.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.1.4
fuelGaugeStaticPowerPcapMaxThis field displays power capping maximum value. Rack system only.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.1.5
fuelGaugeStaticPowerPcapModeThis field is used to display or set the all Power Cap settings to output or input. Rack system only.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.1.10.1.6
fuelGaugeSystemMaxPowerThis field displays the system maximum power available value. Rack system only.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.1.7
fuelGaugePowerRemainingThis field displays power remaining value. Rack system only.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.1.8
fuelGaugeTotalPowerAvailableThis field displays the calculated total remaining power available value. Rack system only.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.1.9
fuelGaugeTotalPowerInUseThis field displays total power in use value.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.1.10
fuelGaugePowerConsumptionCpuThis field displays the power consumption of the processors.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.1.11
fuelGaugePowerConsumptionMemoryThis field displays the power consumption of the memory.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.1.12
fuelGaugePowerConsumptionOtherThis field displays the power consumption of other entities than processors and memory.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.1.13
powerPolicyInformation
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.10.2
powerPolicyTableTable of Power Policy information for all power domains. Reading this table information about the available power policies that can be configured and which is currently selected. Rack system only
SEQUENCE OF PowerPolicyEntry
.1.3.6.1.4.1.19046.11.1.1.10.2.1
powerPolicyEntryPower Policy Entry
PowerPolicyEntry
.1.3.6.1.4.1.19046.11.1.1.10.2.1.1
powerPolicyIndexThe unique idenitifier of a row in the powerPolicyTable.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.2.1.1.1
powerPolicyNameThe short name of the power policy. The following are the possible names and their detailed description: Power Module Redundant In redundant mode, the server is guaranteed to continue to remain operational with the loss of one power supply Power Module Non-Redundant In non-redundant mode, the server is not guaranteed to remain operational with the loss of a power supply. The system will throttle if a power supply fails in an attempt to stay up and running.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.10.2.1.1.2
powerPolicyPwrSupplyFailureLimitThe maximum number of power supplies that can fail in a chassis while still providing redundancy.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.2.1.1.3
powerPolicyMaxPowerLimitThe maximum power available (in watts), based on the number of power modules and the Power Management Policy setting.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.2.1.1.4
powerPolicyEstimatedUtilizationThe estimated utilization (as a percentage) based on current power usage.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.2.1.1.5
powerPolicyActivateThis object provides the status of this power policy. If the value is enabled(1), it means this is the active power policy for the associated domain. When set to a value of enabled(1), the power policy will be made the active one for the associated domain. A set of disabled(0) is not allowed.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.1.10.2.1.1.6
powerRestorePolicyControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.10.2.2
powerRestorePolicyPower Restore Policy determines the mode of operation if a power loss occurs. This setting can also be configured via BIOS F1 setup. Rack system only. alwaysoff: System will remain off once power is restored. restore: Restores system to the same state it was before power failed. alwayson: System will automatically power on once power is restored.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.1.10.2.2.1
powerRestoreDelayPower Restore Delay is executed when power restore policy is set to alwayson or restore(if the previous state was power-on). Rack system only. disabled: Power on the server without after AC is restored. random: Provide a random delay between 1 and 15 seconds from the time when AC is restored to the time when the server is automatically powered on.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.1.10.2.2.2
powerPowerTrending
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.10.3
powerTrendingSampleTableTable of Power Domain 1 Power Trending Information.
SEQUENCE OF PowerTrendingSampleEntry
.1.3.6.1.4.1.19046.11.1.1.10.3.1
powerTrendingSampleEntryPower Domain 1 Power Trending Sample entry.
PowerTrendingSampleEntry
.1.3.6.1.4.1.19046.11.1.1.10.3.1.1
powerTrendingSampleIndexPower Trending Sample Table Index.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.3.1.1.1
powerTrendingSampleTimeStampPower Trending Sample Table Timestamp.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.1.10.3.1.1.2
powerTrendingSampleInputAvePower Trending Table Input Average Power in the last 24 hours.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.3.1.1.3
powerTrendingSampleInputMinPower Trending Table Input Minimum Power in the last 24 hours.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.3.1.1.4
powerTrendingSampleInputMaxPower Trending Table Input Maximum Power in the last 24 hours.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.3.1.1.5
powerTrendingSampleOutputAvePower Trending Table Output Average Power in the last 24 hours.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.3.1.1.6
powerTrendingSampleOutputMinPower Trending Table Output Minimum Power in the last 24 hours.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.3.1.1.7
powerTrendingSampleOutputMaxPower Trending Table Output Maximum Power in the last 24 hours.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.10.3.1.1.8
powerModule
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.11
powerNumberThe present number of rows in the power module table. Rack system only.ro
Gauge
.1.3.6.1.4.1.19046.11.1.1.11.1
powerTableThis table contains power inventory information. Rack system only.
SEQUENCE OF PowerEntry
.1.3.6.1.4.1.19046.11.1.1.11.2
powerEntryEach row contains parameters related to a power module inventory channel.
PowerEntry
.1.3.6.1.4.1.19046.11.1.1.11.2.1
powerIndexThis column is used to identify a particular power module inventory channel.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.11.2.1.1
powerFruNamepower module FRU name.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.11.2.1.2
powerPartNumberpower module Part Number. View as a table and not as individual entries for consistent results.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.11.2.1.3
powerFRUNumberpower module FRU Number. View as a table and not as individual entries for consistent results.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.11.2.1.4
powerFRUSerialNumberpower module Serial Number. View as a table and not as individual entries for consistent results.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.11.2.1.5
powerHealthStatusA description of the power module status.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.11.2.1.6
disks
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.12
diskNumberThe present number of rows in the disk module table.ro
Gauge
.1.3.6.1.4.1.19046.11.1.1.12.1
diskTableThis table contains disk inventory information.
SEQUENCE OF DiskEntry
.1.3.6.1.4.1.19046.11.1.1.12.2
diskEntryEach row contains parameters related to a disk module inventory channel.
DiskEntry
.1.3.6.1.4.1.19046.11.1.1.12.2.1
diskIndexThis column is used to identify a particular disk module inventory channel.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.12.2.1.1
diskFruNamedisk module FRU name.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.12.2.1.2
diskHealthStatusA description of the disk module status.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.1.12.2.1.3
localStorage
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.13
raid
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.13.1
raidOOBCapableIf raidOOBCapable is disabled, all the RAID information is not available.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.1.13.1.1
raidControllerTableTable of Local Storage RAID Controller information.
SEQUENCE OF RaidControllerEntry
.1.3.6.1.4.1.19046.11.1.1.13.1.2
raidControllerEntryRAID Controller Entry.
RaidControllerEntry
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1
raidCtrlIndexThis column is used to identify a particular RAID controller.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.1
raidCtrlNameThis column is used to offer a name of one RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.2
raidCtrlVPDProdNameThe Product Name of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.3
raidCtrlFWPkgVersionThe Firmware Package Version of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.4
raidCtrlBatBCKWhether Battery Backup of a particular RAID controller is installed.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.5
raidCtrlVPDManufactureThe Manufacture of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.6
raidCtrlVPDUUIDThe Device ID (UUID) of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.7
raidCtrlVPDMachineTypeThe Model Type/Model of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.8
raidCtrlVPDModelThe Model Type/Model of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.9
raidCtrlVPDSerialNoThe Serial Number of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.10
raidCtrlVPDFRUNoThe FRU Number of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.11
raidCtrlVPDPartNoThe Part Number of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.12
raidCtrlCacheMdlStatusThe Cache Model Status of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.13
raidCtrlCacheMdlMemSizeThe Cache Model Memory Size of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.14
raidCtrlCacheMdlSerialNoThe Cache Model Serial Number of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.15
raidCtrlPCISlotNoThe PCI Slot Number of a particular RAID controller.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.16
raidCtrlPCIBusNoThe PCI Bus Number of a particular RAID controller.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.17
raidCtrlPCIDevNoThe PCI Device Number of a particular RAID controller.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.18
raidCtrlPCIFuncNoThe PCI Function Number of a particular RAID controller.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.19
raidCtrlPCIDevIDThe PCI Device ID of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.20
raidCtrlPCISubDevIDThe PCI Subsystem Device ID of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.21
raidCtrlBatBCKProdNameThe Product Name of Battery Backup of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.22
raidCtrlBatBCKManufactureThe Manufacture of Battery Backup of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.23
raidCtrlBatBCKStatusThe Status of Battery Backup of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.24
raidCtrlBatBCKTypeThe Battery Type of Battery Backup of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.25
raidCtrlBatBCKChemThe Chemistry of Battery Backup of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.26
raidCtrlBatBCKSerialNoThe Serial Number of Battery Backup of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.27
raidCtrlBatBCKChgCapThe Charge Capacity of Battery Backup of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.28
raidCtrlBatBCKFirmwareThe Firmware Info of Battery Backup of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.29
raidCtrlBatBCKDgnVoltageThe Designed Voltage of Battery Backup of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.30
raidCtrlBatBCKVoltageThe Voltage of Battery Backup of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.31
raidCtrlBatCurrentThe Current of Battery Backup of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.32
raidCtrlBatBCKDgnChgCapThe Design Charge Capacity of Battery Backup of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.33
raidCtrlBatBCKCrtTempThe Current degree Celsius temperature of Battery Backup of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.34
raidCtrlFWNamesAll the Firmware Names of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.35
raidCtrlPortDetailsAll the Port Details of a particular RAID controller, including Port Address and Port Controller Type.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.36
raidCtrlStoragepoolsThe storage pools list of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.37
raidCtrlDrivesThe Physical drives list of a particular RAID controller.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.2.1.38
raidDriveTableTable of Logic Storage RAID Drive information.
SEQUENCE OF RaidDriveEntry
.1.3.6.1.4.1.19046.11.1.1.13.1.3
raidDriveEntryRAID Drive Entry.
RaidDriveEntry
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1
raidDriveIndexThis column is used to identify a particular RAID drive.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.1
raidDriveNameA particular drive name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.2
raidDriveVPDProdNameThe Product Name of a particular RAID drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.3
raidDriveStateThe State of a particular RAID drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.4
raidDriveSlotNoThe Slot No. of a particular RAID drive.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.5
raidDriveDeviceIDThe Device ID of a particular RAID drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.6
raidDriveDiskTypeThe Disk Type of a particular RAID drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.7
raidDriveMediaTypeThe Media Type of a particular RAID drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.8
raidDriveSpeedThe Speed of a particular RAID drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.9
raidDriveCurTempThe Current degree Celsius temperature of a particular RAID drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.10
raidDriveHealthStatausThe Health Status of a particular RAID drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.11
raidDriveCapacityThe Capacity of a particular RAID drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.12
raidDriveVPDManufactureThe Manufacture of a particular RAID drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.13
raidDriveEnclosureIDThe Enclosure ID of a particular RAID drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.14
raidDriveVPDMachineTypeThe Machine type of a particular RAID drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.15
raidDriveVPDModelThe Model of a particular RAID drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.16
raidDriveVPDSerialNoThe Serial No. of a particular RAID drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.17
raidDriveVPDFRUNoThe FRU No. of a particular RAID drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.18
raidDriveVPDPartNoThe Part No. of a particular RAID drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.19
raidDriveFWNamesAll the Firmware Names of a particular RAID drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.20
raidDriveRotationRateThe Rotation Rate of a particular RAID drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.21
raidDriveMediaErrCntThe Media Error Count of a particular RAID drive.ro
Gauge
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.22
raidDriveOtherErrCntThe Other Error Count of a particular RAID drive.ro
Gauge
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.23
raidDrivePredFailCntThe Predication Fail Count of a particular RAID drive.ro
Gauge
.1.3.6.1.4.1.19046.11.1.1.13.1.3.1.24
raidControllerFirmwareTableTable of Logic Storage RAID Controller Firmware information.
SEQUENCE OF RaidControllerFirmwareEntry
.1.3.6.1.4.1.19046.11.1.1.13.1.4
raidControllerFirmwareEntryRAID Firmware Entry.
RaidControllerFirmwareEntry
.1.3.6.1.4.1.19046.11.1.1.13.1.4.1
raidControllerFirmwareIndexThis column is used to identify a particular RAID Controller firmware.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.13.1.4.1.1
raidControllerFirmwareNameThe Name of a particular RAID Controller firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.4.1.2
raidControllerFirmwareCtrlNameThe controller name of the firmwares.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.4.1.3
raidControllerFirmwareDescriptionThe Description of a particular RAID Controller firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.4.1.4
raidControllerFirmwareManufactureThe Manufacture of a particular RAID Controller firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.4.1.5
raidControllerFirmwareVersionThe Version of a particular RAID Controller firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.4.1.6
raidControllerFirmwareReleaseDateThe Release Date of a particular RAID Controller firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.4.1.7
raidDriveFirmwareTableTable of Logic Storage RAID Drive Firmware information.
SEQUENCE OF RaidDriveFirmwareEntry
.1.3.6.1.4.1.19046.11.1.1.13.1.5
raidDriveFirmwareEntryRAID Drive Firmware Entry.
RaidDriveFirmwareEntry
.1.3.6.1.4.1.19046.11.1.1.13.1.5.1
raidDriveFirmwareIndexThis column is used to identify a particular RAID Drive firmware.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.13.1.5.1.1
raidDriveFirmwareNameThe Name of a particular RAID Drive firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.5.1.2
raidDriveFirmwareDriveNameThe drive name of the firmwares.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.5.1.3
raidDriveFirmwareDescriptionThe Description of a particular RAID Drive firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.5.1.4
raidDriveFirmwareManufactureThe Manufacture of a particular RAID Drive firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.5.1.5
raidDriveFirmwareVersionThe Version of a particular RAID Drive firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.5.1.6
raidDriveFirmwareReleaseDateThe Release Date of a particular RAID Drive firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.5.1.7
raidStoragepoolTableTable of Logic Storage RAID Storagepool information.
SEQUENCE OF RaidStoragepoolEntry
.1.3.6.1.4.1.19046.11.1.1.13.1.6
raidStoragepoolEntryRAID Storagepool Entry.
RaidStoragepoolEntry
.1.3.6.1.4.1.19046.11.1.1.13.1.6.1
raidStoragepoolIndexThis column is used to identify a particular RAID storagepool.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.13.1.6.1.1
raidStoragepoolNameThe name of a particular RAID storagepool.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.6.1.2
raidStoragepoolControllerNameThe controller name of the storagepool.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.6.1.3
raidStoragepoolStateThe RAID State of a particular RAID storagepool.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.6.1.4
raidStoragepoolCapacityThe Capacity of a particular RAID storagepool, including total capacity and free capacity.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.6.1.5
raidStoragepoolVolsThe volumes list of a particular RAID storagepool.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.6.1.6
raidStoragepoolDrivesThe physical drives list of a particular RAID storagepool.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.6.1.7
raidVolumeTableTable of Logic Storage RAID Volume information.
SEQUENCE OF RaidVolumeEntry
.1.3.6.1.4.1.19046.11.1.1.13.1.7
raidVolumeEntryRAID Volume Entry.
RaidVolumeEntry
.1.3.6.1.4.1.19046.11.1.1.13.1.7.1
raidVolumeIndexThis column is used to identify a particular RAID volume.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.13.1.7.1.1
raidVolumeNameThe Name of a particular RAID volume.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.7.1.2
raidVolumeControllerNameThe controller name of the volume.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.7.1.3
raidVolumeStatusThe Status of a particular RAID volume.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.7.1.4
raidVolumeCapacityThe Capacity of a particular RAID volume.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.7.1.5
raidVolumeStripSizeThe strip size of the RAID volume.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.7.1.6
raidVolumeBootableWhether the RAID volume is bootable.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.13.1.7.1.7
adapters
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.1.14
adapterOOBCapableIf adapterOOBCapable is disabled, all the adapter information is not available.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.1.14.1
adapterGenericTableTable of all adapters generic information
SEQUENCE OF AdapterGenericEntry
.1.3.6.1.4.1.19046.11.1.1.14.2
adapterGenericEntryAdapters generic information entry.
AdapterGenericEntry
.1.3.6.1.4.1.19046.11.1.1.14.2.1
adapterGenericIndexThis column is used to identify a particular PCI adapter.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.2.1.1
adapterGenericVPDProdNameThe Product Name of a particular PCI adapter. And if the Product Name contains PFA, PFA is in HEX.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.2.1.2
adapterGenericSlotNoThis Slot No. of a particular PCI adapterro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.2.1.3
adapterGenericLocationThe Location of a particular PCI adapter.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.2.1.4
adapterGenericCardInterfaceThe Card Interface of a particular PCI adapter.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.2.1.5
adapterNetworkFunctionTableTable of Network Function information.
SEQUENCE OF AdapterNetworkFunctionEntry
.1.3.6.1.4.1.19046.11.1.1.14.3
adapterNetworkFunctionEntryNetwork function information entry.
AdapterNetworkFunctionEntry
.1.3.6.1.4.1.19046.11.1.1.14.3.1
adapterNetworkFunctionIndexThis column is used to identify a particular network function.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.3.1.1
adapterNetworkFunctionNetworkVPDProdNameThe Product Name and PFA of a particular network function and PFA is in HEX.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.3.1.2
adapterNetworkFunctionAdapterVPDProdNameThe Product Name of a particular adapter providing this function. And if the Product Name contains PFA, PFA is in HEX.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.3.1.3
adapterNetworkFunctionNetworkVPDManufacturerThe Manufacturer of a particular network function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.3.1.4
adapterNetworkFunctionNetworkVPDUUIDThe UUID of a particular network function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.3.1.5
adapterNetworkFunctionNetworkVPDModelThe Model of a particular network function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.3.1.6
adapterNetworkFunctionNetworkVPDSerialNoThe Serial No. of a particular network function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.3.1.7
adapterNetworkFunctionNetworkVPDFRUNoThe FRU No. of a particular network function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.3.1.8
adapterNetworkFunctionNetworkVPDPartNoThe Part No. of a particular network function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.3.1.9
adapterNetworkFunctionFoDUIDThe FoD UID of a particular network function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.3.1.10
adapterNetworkFunctionSupportHotPlugIndicates whether the network function supports hot plug.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.1.14.3.1.11
adapterNetworkFunctionPhysicalPortNumberThe Physical Port Number of a particular network function.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.3.1.12
adapterNetworkFunctionMaxPortNumberThe Max Port Number of a particular network function.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.3.1.13
adapterNetworkFunctionPortNumberThe Port Number of a particular network function.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.3.1.14
adapterNetworkFunctionMaxDataWidthThe Maximum Data Width in Gbps of a particular network funtion.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.3.1.15
adapterNetworkFunctionPackageTypeThe Package Type of a particular network function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.3.1.16
adapterNetworkFunctionPCIBusNoThe PCI Bus No. of a particular network function.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.3.1.17
adapterNetworkFunctionPCIDevNoThe PCI Device No. of a particular network function.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.3.1.18
adapterNetworkFunctionPCIFuncNoThe PCI Function No. of a particular network function.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.3.1.19
adapterNetworkFunctionPCIVendorIdThe PCI Vendor ID of a particular network function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.3.1.20
adapterNetworkFunctionPCIDevIdThe PCI Device ID of a particular network function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.3.1.21
adapterNetworkFunctionPCIDevTypeThe PCI Device Type of a particular network function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.3.1.22
adapterNetworkFunctionPCIRevIdThe PCI Revision ID of a particular network function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.3.1.23
adapterNetworkFunctionPCISubVendorIdThe PCI Subsystem Vendor ID of a particular network function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.3.1.24
adapterNetworkFunctionPCISubDevIdThe PCI Subsystem Device ID of a particular network function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.3.1.25
adapterNetworkFunctionPCISlotDesignationThe PCI Slot Designation of a particular network function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.3.1.26
adapterNetworkPortTableTable of Ports of Network Function information.
SEQUENCE OF AdapterNetworkPortEntry
.1.3.6.1.4.1.19046.11.1.1.14.4
adapterNetworkPortEntryPorts of Network Function information entry.
AdapterNetworkPortEntry
.1.3.6.1.4.1.19046.11.1.1.14.4.1
adapterNetworkPortIndexThis column is used to identify a particular network port.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.4.1.1
adapterNetworkPortNetworkVPDProdNameThe Product Name and PFA of the network function for this port and PFA is in HEX.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.4.1.2
adapterNetworkPortPhyPortNoThe Physical Port No. in the network function for this port.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.4.1.3
adapterNetworkPortPhyPortConnectorThe Physical Port Connector Layout in the network function for this port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.4.1.4
adapterNetworkPortPhyPortBurnedinAddressThe Physical Permanent (burned-In) Address of a particular network port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.4.1.5
adapterNetworkPortNoThe Port No. of this network port in the network function.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.4.1.6
adapterNetworkPortMaxDataSizeThe Port Max Data Size of this network port in the network function.ro
Gauge
.1.3.6.1.4.1.19046.11.1.1.14.4.1.7
adapterNetworkPortPermanentAddressThe Permanent Address of a particular network port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.4.1.8
adapterNetworkPortNetworkAddressThe Network Address of a particular network port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.4.1.9
adapterNetworkPortLinkTechnologyThe Link Technology of a particular network port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.4.1.10
adapterNetworkPortvNICModeIf the logical port vNIC mode is Virtual Fabric mode, Switch Independent mode, or Unified Fabric Protocol mode, this column returns 1(enabled), otherwise, the columen returns 0(disabled)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.4.1.11
adapterNetworkPortMaxSpeedThe Maximum Bandwidth in Gbps of a particular network port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.4.1.12
adapterNetworkPortProtocolTypeThe Protocol Type of a particular network port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.4.1.13
adapterNetworkPortCurrentProtocolThe Current Work Protocol of a particular network port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.4.1.14
adapterNetworkPortFCoEPermanentAddressThe FCoE Permanent Address of a particular network port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.4.1.15
adapterNetworkPortFCoENetworkAddressThe FCoE Network Address of a particular network port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.4.1.16
adapterNetworkPortConnectionTypeThe Connection Type of a particular network port if its current work protocol is FC or FCoE.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.4.1.17
adapterNetworkPortRoleThe Port Role of a particular network port if its current work protocol is FC or FCoE.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.4.1.18
adapterNetworkPortTargetRelativePortNoThe Target Relative Port No. of a particular network port if its current work protocol is FC or FCoE.ro
Gauge
.1.3.6.1.4.1.19046.11.1.1.14.4.1.19
adapterNetworkPortPhyPortLinkStatusThe Physical Port Link Status in the network function for this port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.4.1.20
adapterNetworkPortPhyPortLinkSpeedThe Physical Port Link Speed in the network function for this port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.4.1.21
adapterGPUFunctionTableTable of GPU Function information.
SEQUENCE OF AdapterGPUFunctionEntry
.1.3.6.1.4.1.19046.11.1.1.14.5
adapterGPUFunctionEntryGPU function information entry.
AdapterGPUFunctionEntry
.1.3.6.1.4.1.19046.11.1.1.14.5.1
adapterGPUFunctionIndexThis column is used to identify a particular GPU function.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.5.1.1
adapterGPUFunctionGpuVPDProdNameThe Product Name and PFA of a particular GPU function and PFA is in HEX.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.2
adapterGPUFunctionAdapterVPDProdNameThe Product Name of a particular adapter providing this function. And if the Product Name contains PFA, PFA is in HEX.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.3
adapterGPUFunctionGpuVPDManufacturerThe Manufacturer of a particular GPU function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.4
adapterGPUFunctionGpuVPDUUIDThe UUID of a particular GPU function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.5
adapterGPUFunctionGpuVPDModelThe Model of a particular GPU function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.6
adapterGPUFunctionGpuVPDSerialNoThe Serial No. of a particular GPU function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.7
adapterGPUFunctionGpuVPDFRUNoThe FRU No. of a particular GPU function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.8
adapterGPUFunctionGpuVPDPartNoThe Part No. of a particular GPU function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.9
adapterGPUFunctionFoDUIDThe FoD UID of a particular GPU function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.10
adapterGPUFunctionSupportHotPlugIndicates whether the GPU function supports hot plug.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.1.14.5.1.11
adapterGPUFunctionVideoMemorySizeThe Video Memory Size of a particular GPU function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.12
adapterGPUFunctionVideoMemoryTypeThe Video Memory Type of a particular GPU function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.13
adapterGPUFunctionChipNumberThe Chip Number of a particular GPU function.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.5.1.14
adapterGPUFunctionMaxDataWidthThe Maximum Data Width in Gbps of a particular GPU funtion.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.5.1.15
adapterGPUFunctionPackageTypeThe Package Type of a particular GPU function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.16
adapterGPUFunctionPCIBusNoThe PCI Bus No. of a particular GPU function.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.5.1.17
adapterGPUFunctionPCIDevNoThe PCI Device No. of a particular GPU function.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.5.1.18
adapterGPUFunctionPCIFuncNoThe PCI Function No. of a particular GPU function.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.5.1.19
adapterGPUFunctionPCIVendorIdThe PCI Vendor ID of a particular GPU function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.20
adapterGPUFunctionPCIDevIdThe PCI Device ID of a particular GPU function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.21
adapterGPUFunctionPCIDevTypeThe PCI Device Type of a particular GPU function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.22
adapterGPUFunctionPCIRevIdThe PCI Revision ID of a particular GPU function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.23
adapterGPUFunctionPCISubVendorIdThe PCI Subsystem Vendor ID of a particular GPU function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.24
adapterGPUFunctionPCISubDevIdThe PCI Subsystem Device ID of a particular GPU function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.25
adapterGPUFunctionPCISlotDesignationThe PCI Slot Designation of a particular GPU function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.5.1.26
adapterGPUChipTableTable of Chips of GPU Function information.
SEQUENCE OF AdapterGPUChipEntry
.1.3.6.1.4.1.19046.11.1.1.14.6
adapterGPUChipEntryGPU function chip information entry.
AdapterGPUChipEntry
.1.3.6.1.4.1.19046.11.1.1.14.6.1
adapterGPUChipIndexThis column is used to identify a particular GPU chipro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.6.1.1
adapterGPUChipGpuVPDProdNameThe Product Name and PFA of the GPU function for this chip and PFA is in HEX.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.6.1.2
adapterGPUChipNoThe Index of the GPU chip in the GPU adapter.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.6.1.3
adapterGPUChipNameThe Name of a particular GPU chip.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.6.1.4
adapterGPUChipFamilyThe Family Name of a particular GPU chip.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.6.1.5
adapterGPUChipManufacturerThe Manufacturer of a particular GPU chip.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.6.1.6
adapterGPUChipCoresEnabledIndicates whether enable cores of a particular GPU chip.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.6.1.7
adapterGPUChipMaxClockSpeedThe Maximum Clock Speed in MHz of a particular GPU chip.ro
Gauge
.1.3.6.1.4.1.19046.11.1.1.14.6.1.8
adapterGPUChipExtBusClockSpeedThe External Bus Clock Speed in MHz of a particular GPU chip.ro
Gauge
.1.3.6.1.4.1.19046.11.1.1.14.6.1.9
adapterGPUChipAddressWidthThe Address Width of a particular GPU chip.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.6.1.10
adapterGPUChipDataWidthThe Data Width of a particular GPU chip.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.6.1.11
adapterGPUChipFormFactorThe Form Factor of a particular GPU chip.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.6.1.12
adapterGPUChipModelThe Model of a particular GPU chip.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.6.1.13
adapterGPUChipSerialNoThe Serial No. of a particular GPU chip.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.6.1.14
adapterGPUChipFRUNoThe FRU No. of a particular GPU chip.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.6.1.15
adapterGPUChipPartNoThe Part No. of a particular GPU chip.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.6.1.16
adapterGPUChipUniqueIDThe Unique ID of a particular GPU chip.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.6.1.17
adapterRAIDFunctionTableTable of RAID Function information.
SEQUENCE OF AdapterRAIDFunctionEntry
.1.3.6.1.4.1.19046.11.1.1.14.7
adapterRAIDFunctionEntryRAID function information entry.
AdapterRAIDFunctionEntry
.1.3.6.1.4.1.19046.11.1.1.14.7.1
adapterRAIDFunctionIndexThis column is used to identify a particular RAID function.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.7.1.1
adapterRAIDFunctionRaidVPDProdNameThe Product Name and PFA of a particular RAID function and PFA is in HEX.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.7.1.2
adapterRAIDFunctionAdapterVPDProdNameThe Product Name of a particular adapter providing this function. And if the Product Name contains PFA, PFA is in HEX.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.7.1.3
adapterRAIDFunctionRaidVPDManufacturerThe Manufacturer of a particular RAID function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.7.1.4
adapterRAIDFunctionRaidVPDUUIDThe UUID of a particular RAID function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.7.1.5
adapterRAIDFunctionRaidVPDModelThe Model of a particular RAID function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.7.1.6
adapterRAIDFunctionRaidVPDSerialNoThe Serial No. of a particular RAID function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.7.1.7
adapterRAIDFunctionRaidVPDFRUNoThe FRU No. of a particular RAID function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.7.1.8
adapterRAIDFunctionRaidVPDPartNoThe Part No. of a particular RAID function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.7.1.9
adapterRAIDFunctionFoDUIDThe FoD UID of a particular RAID function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.7.1.10
adapterRAIDFunctionSupportHotPlugIndicates whether the RAID function supports hot plug.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.1.14.7.1.11
adapterRAIDFunctionMaxDataWidthThe Maximum Data Width in Gbps of a particular RAID funtion.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.7.1.12
adapterRAIDFunctionPackageTypeThe Package Type of a particular RAID function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.7.1.13
adapterRAIDFunctionPCIBusNoThe PCI Bus No. of a particular RAID function.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.7.1.14
adapterRAIDFunctionPCIDevNoThe PCI Device No. of a particular RAID function.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.7.1.15
adapterRAIDFunctionPCIFuncNoThe PCI Function No. of a particular RAID function.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.7.1.16
adapterRAIDFunctionPCIVendorIdThe PCI Vendor ID of a particular RAID function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.7.1.17
adapterRAIDFunctionPCIDevIdThe PCI Device ID of a particular RAID function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.7.1.18
adapterRAIDFunctionPCIDevTypeThe PCI Device Type of a particular RAID function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.7.1.19
adapterRAIDFunctionPCIRevIdThe PCI Revision ID of a particular RAID function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.7.1.20
adapterRAIDFunctionPCISubVendorIdThe PCI Subsystem Vendor ID of a particular RAID function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.7.1.21
adapterRAIDFunctionPCISubDevIdThe PCI Subsystem Device ID of a particular RAID function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.7.1.22
adapterRAIDFunctionPCISlotDesignationThe PCI Slot Designation of a particular RAID function.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.7.1.23
adapterFirmwareTableTable of PCI Function Firmware information.
SEQUENCE OF AdapterFirmwareEntry
.1.3.6.1.4.1.19046.11.1.1.14.8
adapterFirmwareEntryAdapter Firmware Entry.
AdapterFirmwareEntry
.1.3.6.1.4.1.19046.11.1.1.14.8.1
adapterFwIndexThis column is used to identify a particular function firmware.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.1.14.8.1.1
adapterFwFunctionVPDProdNameThe Product Name and PFA of a particular function for this firmware and PFA is in HEX.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.8.1.2
adapterFwNameThe name of a particular PCI function firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.8.1.3
adapterFwClassificationThe classification of a particular PCI function firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.8.1.4
adapterFwDescriptionThe description of a particular PCI function firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.8.1.5
adapterFwManufactureThe manufacturer of a particular PCI function firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.8.1.6
adapterFwVersionThe version of a particular PCI function firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.8.1.7
adapterFwReleaseDateThe release date of a particular PCI function firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.8.1.8
adapterFwSoftwareIDThe Software ID of a particular PCI function firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.1.14.8.1.9
errorLogs
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.2
eventLog
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.2.1
eventLogTableTable of event logs. View as a table and not as individual entries for consistent results.
SEQUENCE OF EventLogEntry
.1.3.6.1.4.1.19046.11.1.2.1.1
eventLogEntryEvent log entries. View as a table and not as individual entries for consistent results.
EventLogEntry
.1.3.6.1.4.1.19046.11.1.2.1.1.1
eventLogIndexEvent log index number. View as a table and not as individual entries for consistent results.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.2.1.1.1.1
eventLogStringContains a string of information to detail the event. View as a table and not as individual entries for consistent results.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.2.1.1.1.2
eventLogSeverityContains a information to detail the severity of the event. View as a table and not as individual entries for consistent results.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.2.1.1.1.3
eventLogDateThe Date of the Event occured. View as a table and not as individual entries for consistent results.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.2.1.1.1.4
eventLogTimeThe Time of the Event occured. View as a table and not as individual entries for consistent results.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.2.1.1.1.5
eventLogTftpServerTo save the eventLog if it is not empty, the IP address or host name of the TFTP server where the file should be transferred.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.2.1.4
eventLogFileNameFile name of the saved log file on the target system.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.2.1.5
configureSP
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3
remoteAccessConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.1
generalRemoteCfg
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.1.1
remoteAlertRetryDelayNumber in seconds to delay between retries if sending a remote alert is unsuccessful.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.1
remoteAlertRetryCountNumber of additional times a remote alert will be retried if not succesfully sent. A value of zero indicates no retries will be attempted.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.2
remoteAlertEntryDelayNumber in seconds to delay between entries if sending a remote alert is unsuccessful.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.3
snmpCriticalAlertsIf Enabled,criticalAlerts will be sent to SNMP, else critical alerts will not be sent.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.4
snmpWarningAlertsIf Enabled,warningAlerts will be sent to SNMP , else warning alerts will not be sent.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.5
snmpSystemAlertsIf Enabled,systemAlerts will be sent to SNMP , else system alerts will not be sent.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.6
remoteAccessTamperDelayNumber in minutes to prohibit a remote login attempt after more than maximum login attempts have failed. The minimum value is 0 and the maximum value is 2880 minute. The default value is 60 minutes.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.1.7
userAuthenticationMethodUse this field to specify how users attempting to login should be authenticated. There are two methods: Local authentication. Userid and password are verified by searching the list of users locally configured under Local Login Profiles. LDAP based authentication. Users are authenticated via a remote LDAP server. One or both authentication methods can be selected. If both methods should be used, the order must be specified.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.8
webInactivityTimeoutThe amount of time, in minutes, that a user session established with the management server can be inactive before the user is logged out. The minimum value is 0 and the maximum value is 1440 minutes. The default value is 20 minutes. If the value is 0, web session never expire.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.1.9
snmpAlertFilters
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.1.1.10
safSpTrapTempCCritical Alert: Temperature threshold exceeded.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.2
safSpTrapVoltCCritical Alert: Voltage threshold exceeded.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.3
safSpTrapPowerCCritical Alert: Power failure.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.4
safSpTrapHdCCritical Alert: Hard disk drive failure.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.5
safSpTrapFanCCritical Alert: Single Fan failure.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.6
safSpTrapIhcCCritical Alert: Incompatible hardware configuration.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.7
safSpTrapCPUCCritical Alert: CPU Error.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.8
safSpTrapMemoryCCritical Alert: Memory Error.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.9
safSpTrapRdpsCCritical Alert: Redundant Power Supply failure.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.10
safSpTrapHardwareCCritical Alert: Other Failure - refer to Message ID for specific condition.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.11
safSpTrapRdpsNNon-Critical Alert: Redundant Power Supply failure.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.12
safSpTrapTempNNon-Critical Alert: Temperature threshold exceeded.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.13
safSpTrapVoltNNon-Critical Alert: Voltage threshold exceeded.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.14
safSpTrapPowerNNon-Critical Alert: Power.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.15
safSpTrapFanNNon-Critical Alert: Fan Error.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.16
safSpTrapCPUNNon-Critical Alert: Memory Error.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.17
safSpTrapMemoryNNon-Critical Alert: Memory Error.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.18
safSpTrapHardwareNNon-Critical Alert: Warning - refer to Message ID for specific condition.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.19
safSpTrapRLoginSev-Off Alert: Event Remote Login.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.20
safSpTrapOsToSSystem Alert: OS Timeout value exceeded.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.21
safSpTrapAppSSystem Alert: Application Alert. Refer to Message ID for specific condition.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.22
safSpTrapPowerSSystem Alert: Power on or off.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.23
safSpTrapBootSSystem Alert: System Boot Failure.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.24
safSpTrapLdrToSSystem Alert: OS Loader Timeout.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.25
safSpTrapPFASSystem Alert: Predictive Failure Analysis(PFA) information.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.26
safSpTrapSysLogSSystem Alert: System Log 75% full.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.27
safSpTrapNwChangeSSystem Alert: Network change notification.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.1.10.28
customSecuritySettings
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.1.1.20
passwordExpirationWarningPeriodThe amount of time, in days, before password expiration that users will begin to receive warnings about the impending expiration of the user password. The minimum value is 0 and the maximum value is the maximum password expiration period. The default value is 5 days. A value of 0 means that the users are never warned.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.1.20.1
passwordExpirationPeriodThe amount of time, in days, that a user may use a password before it must be changed. Smaller values reduce the amount of time for attackers to guess passwords. The minimum value is 0 and the maximum value is 365 days. The default value is 90 days. A value of 0 means that the password never expire.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.1.20.2
minimumPasswordReuseCycleThe minimum number of the times that a user must enter a unique password before the user can start to reuse passwords. A higher number enhances security. The minimum value is 0 and the maximum value is 10 times. The default value is 5 times. A value of 0 means that passwords may be reused immediately.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.1.20.3
minimumPasswordLengthThe minimum number of characters that can be used to specify a valid password. The minimum value is 8 characters and the maximum value is 20 characters. The default value is 8 characters.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.1.20.5
defaultAdminPasswordExpiredA value of 1 means that the factory default 'USERID' account password must be changed on next login. A value of 0 means that there is no such requirement. The default value is 0.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.1.20.6
changePasswordFirstAccessA value of 1 means that a user is required to change the password when the user logs in to the management server for the first time. A value of 0 means no such requirment. The default value is 1.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.1.20.8
accountLockoutPeriodThe minimum about of time, in minutes, that must pass before a user that was locked out can attempt to log back in again. The minimum value is 0 and the maximum value is 2880 minutes. The default value is 60 minutes. A value of 0 can make your system more exposed to serious denial of service attacks, where deliberate failed login attempts can leave accounts permanently locked.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.1.20.9
maxLoginFailuresThe maximum number of times that a user can attempt to log in with an incorrect password before the user account is locked out. The number specified for the lockout period after maximum login failures determines how long the user account is locked out. Accounts that are locked cannot be used to gain access to the system even if a valid password is provided. The maximum value is 10 times. The default value is 5 times. A value of 0 means that accounts are never locked.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.1.20.10
passwordChangeIntervalThe minimum about of time, in hours, that must elapse before a user may change a password again after it has been changed once. The value specified for this setting would not exceed the value specified for the password expiration period. A small value allows users to more quickly use old passwords. The range of acceptable values will be from 0 to 240 hours. The default value is 24 hours. If the value is 0, passwords may be changed immediately.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.1.20.11
serialPortCfg
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.1.2
portBaudBaud rate for the serial port.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.2.1
portParityParity setting for the serial port.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.2.2
serialRedirect
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.1.2.3
enterCLIkeySeqThis is the keystroke sequence used to enter the CLI. This sequence must have at least one character. The caret symbol (^) has a special meaning in this sequence. It denotes 'Ctrl' for keystrokes that map to Ctrl sequences (for example, ^[ for the escape key and ^M for carriage return). All ocurrences of ^ will be interpreted as part of a Ctrl sequence. Refer to an ASCII-to-key conversion table for a complete list of Ctrl sequences. The default value for this field is '^[(' i.e. ESC followed by (.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.1.2.3.1
portStopBitsNumber of stop bits for the serial port.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.2.4
portCLImodeUse this field to select the CLI (command line interface) mode for this port. The CLI mode disablies serial redirect, or pecifies the type of keystroke sequences to use for entering (returning to) the CLI from the system console.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.2.18
remoteAlertIds
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.1.3
remoteAlertIdsTableTable of remote alert entries. This table lets you configure remote alert recipients. You can define up to 12 unique recipients.
SEQUENCE OF RemoteAlertIdsEntry
.1.3.6.1.4.1.19046.11.1.3.1.3.1
remoteAlertIdsEntryRemote alert entries.
RemoteAlertIdsEntry
.1.3.6.1.4.1.19046.11.1.3.1.3.1.1
remoteAlertIdEntryIndexIndex for remote alert entry.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.3.1.1.1
remoteAlertIdEntryStatusIf enabled alerts will be sent to this alert recipient else alerts will not be sent.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.1.1.2
remoteAlertIdEntryNameA null terminated string that contains a text description of this entry.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.1.3.1.1.3
remoteAlertIdEmailAddrA null terminated string that contains a E-Mail Address. For example 'jeb@us.lenovo.com'. Used only for a E-mail over Lan.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.1.3.1.1.4
remoteAlertIdEntryCriticalAlertIf Enabled,criticalAlerts will be sent to this remote alert receipient,else critical alerts will not be sent.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.1.1.5
remoteAlertIdEntryWarningAlertIf Enabled,warningAlerts will be sent to this remote alert receipient,else warningAlerts will not be sent.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.1.1.6
remoteAlertIdEntrySystemAlertIf Enabled,systemAlerts will be sent to this remote alert receipient,else systemAlerts will not be sent.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.1.1.7
remoteAlertIdEntryAuditAlertIf Enabled,systemAlerts will be sent to this remote alert receipient,else systemAlerts will not be sent.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.1.1.8
remoteAlertIdEntryAttachmentsToEmailAlertsIndicates if the event log should be attached to a email alert.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.1.1.9
remoteAlertIdEntrySyslogPortAssignmentSyslog port number.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.3.1.1.10
remoteAlertIdEntrySyslogHostnameSyslog hostname or IP address.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.1.3.1.1.11
remoteAlertIdEntryTypeAlert recipient type.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.1.1.12
remoteAlertFiltersTableTable of Alert Filters. The entries (rows) in this table correspond 1-1 with the entries in the remoteAlertIdsTable. They are correlated by index.
SEQUENCE OF RemoteAlertFiltersEntry
.1.3.6.1.4.1.19046.11.1.3.1.3.2
remoteAlertFiltersEntryRemote Filters entries.
RemoteAlertFiltersEntry
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1
rafIndexIndex for User Authority Level entry.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.1
rafSpTrapTempCCritical Alert: Temperature threshold exceeded.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.2
rafSpTrapVoltCCritical Alert: Voltage threshold exceeded.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.3
rafSpTrapPowerCCritical Alert: Power failure.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.4
rafSpTrapHdCCritical Alert: Hard disk drive failure.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.5
rafSpTrapFanCCritical Alert: Single Fan failure.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.6
rafSpTrapIhcCCritical Alert: Incompatible hardware configuration.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.7
rafSpTrapCPUCCritical Alert: CPU Error.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.8
rafSpTrapMemoryCCritical Alert: Memory Error.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.9
rafSpTrapRdpsCCritical Alert: Redundant Power Supply failure.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.10
rafSpTrapHardwareCCritical Alert: Other Failure - refer to Message ID for specific condition.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.11
rafSpTrapRdpsNNon-Critical Alert: Redundant Power Supply failure.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.12
rafSpTrapTempNNon-Critical Alert: Temperature threshold exceeded.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.13
rafSpTrapVoltNNon-Critical Alert: Voltage threshold exceeded.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.14
rafSpTrapPowerNNon-Critical Alert: Power.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.15
rafSpTrapFanNNon-Critical Alert: Fan Error.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.16
rafSpTrapCPUNNon-Critical Alert: Memory Error.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.17
rafSpTrapMemoryNNon-Critical Alert: Memory Error.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.18
rafSpTrapHardwareNNon-Critical Alert: Warning - refer to Message ID for specific condition.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.19
rafSpTrapRLoginSev-Off Alert: Event Remote Login.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.20
rafSpTrapOsToSSystem Alert: OS Timeout value exceeded.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.21
rafSpTrapAppSSystem Alert: Application Alert. Refer to Message ID for specific condition.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.22
rafSpTrapPowerSSystem Alert: Power On or Off.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.23
rafSpTrapBootSSystem Alert: System Boot Failure.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.24
rafSpTrapLdrToSSystem Alert: OS Loader Timeout.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.25
rafSpTrapPFASSystem Alert: Predictive Failure Analysis(PFA) information.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.26
rafSpTrapSysLogSSystem Alert: System Log 75% full.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.27
rafSpTrapNwChangeSSystem Alert: Network change notification.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.28
rafSpTrapAllAuditSSystem Alert: All Audit Events notification.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.3.2.1.29
remoteAccessIds
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.1.4
remoteAccessIdsTableTable of remote access profiles. This table lets you to configure all login profiles. You can define up to 12 unique profiles. Note: By default, the remote supervisor adapter comes configured with one login profile that allows remote access using a login ID of 'USERID' and a password of 'PASSW0RD' (the 0 is a zero). To avoid a potential security exposure, we strongly recommend that you change this default Login Profile to values of your choice.
SEQUENCE OF RemoteAccessIdsEntry
.1.3.6.1.4.1.19046.11.1.3.1.4.1
remoteAccessIdsEntryRemote access entries.
RemoteAccessIdsEntry
.1.3.6.1.4.1.19046.11.1.3.1.4.1.1
remoteAccessIdEntryIndexIndex for Remote access entry.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.4.1.1.1
remoteAccessIdEntryUserIdRemote access entry null terminated string that contains the user-id. This can only be modified from blank to non-blank, then back to blank.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.1.4.1.1.2
remoteAccessIdEntryUserPwdLeftDaysleft days before password expired for selected userro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.4.1.1.3
remoteAccessUserAuthorityLevelTableTable of user authority level profiles.
SEQUENCE OF RemoteAccessUserAuthorityLevelEntry
.1.3.6.1.4.1.19046.11.1.3.1.4.2
remoteAccessUserAuthorityLevelEntryUser authority level entries.
RemoteAccessUserAuthorityLevelEntry
.1.3.6.1.4.1.19046.11.1.3.1.4.2.1
ualIndexIndex for User Authority Level entry.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.4.2.1.1
ualIdUser IDro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.1.4.2.1.2
ualSupervisorUser has no restrictions.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.4.2.1.3
ualReadOnlyUser has only read-only access, and cannot perform any save, modify, clear, or state affecting operations (eg. restart XCC, restore defaults, upgrade the firmware, etc.).ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.4.2.1.4
ualAccountManagementIt is custom user authority level. User can add/modify/delete users and change the global login settings in the Login Profiles panel. NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.4.2.1.5
ualConsoleAccessIt is custom user authority level. User can access the remote console. NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.4.2.1.6
ualConsoleAndVirtualMediaAccessIt is custom user authority level. User can access both the remote console and the virtual media feature. NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.4.2.1.7
ualServerPowerAccessIt is custom user authority level. User can access the power on and restart functions for the remote server. These functions are available via the Power/Restart panel. NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.4.2.1.8
ualAllowClearLogIt is custom user authority level. User can clear the event logs. Everyone can look at the event logs, but this particular permission is required to clear the logs. NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.4.2.1.9
ualAdapterBasicConfigIt is custom user authority level. User can modify configuration parameters in the System Settings and Alerts panels. NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.4.2.1.10
ualAdapterNetworkAndSecurityConfigIt is custom user authority level. User can modify configuration parameters in the Security, Network Protocols, Network Interface, Port Assignments, and Serial Port panels. NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.4.2.1.11
ualAdapterAdvancedConfigIt is custom user authority level. User has no restrictions when configuring the adapter. In addition, the user is said to have administrative access to the XCC, meaning that the user can also perform the following advanced functions: firmware upgrades, PXE network boot, restore adapter factory defaults, modify and restore adapter configuration from a configuration file, and restart/reset the adapter. NOTE: The value is meaningless for this MIB object if the ualSupervisor or ualReadOnly is enabled.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.4.2.1.12
groupProfiles
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.1.5
groupIdsTableTable of Group profiles. This table lets you to configure all group profiles. You can define up to 16 unique profiles.
SEQUENCE OF GroupIdsEntry
.1.3.6.1.4.1.19046.11.1.3.1.5.1
groupIdsEntryGroup ID entries.
GroupIdsEntry
.1.3.6.1.4.1.19046.11.1.3.1.5.1.1
groupIndexIndex for Group IDs entry.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.5.1.1.1
groupIdGroup ID. It is a null terminated string that contains the group-id. It must not be a duplicate of any previously configured ones.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.1.5.1.1.2
groupRoleGroup Role. It indicates if the group has supervisor, operator, or custom access.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.1.5.1.1.3
groupRBSroleTableTable of Group Role profiles.
SEQUENCE OF GroupRBSroleEntry
.1.3.6.1.4.1.19046.11.1.3.1.5.2
groupRBSroleEntryGroup Role entries.
GroupRBSroleEntry
.1.3.6.1.4.1.19046.11.1.3.1.5.2.1
groupRBSroleIndexIndex for Group Role entry.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.5.2.1.1
groupRBSroleIdGroup IDro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.1.5.2.1.2
groupRBSSupervisorGroup has no restrictions.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.5.2.1.3
groupRBSOperatorGroup has read-only access, and cannot perform any save, modify, clear, or state affecting operations (e.g. restart XCC, restore defaults, upgrade the firmware, etc.).ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.5.2.1.4
groupRBSNetworkSecurityGroup can modify the configuration in the Security, Network Protocols, Network Interface, Port Assignments, and Serial Port panels.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.5.2.1.5
groupRBSUserAccountManagementGroup can add/modify/delete users and change the Global Login Settings in the Login Profiles panel.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.5.2.1.6
groupRBSRemoteConsoleAccessGroup can access the remote server console.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.5.2.1.7
groupRBSRemoteConsoleRemoteDiskAccessGroup can access the remote server console and the remote disk functions for the remote server.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.5.2.1.8
groupRBSServerPowerRestartAccessGroup can access the power on, restart and server timeout functions for the remote server.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.5.2.1.9
groupRBSBasicAdapterConfigurationGroup can modify configuration parameters in the System Settings (excluding Contact, Location and Server Timeouts) and Alerts panels.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.5.2.1.10
groupRBSClearEventLogGroup can clear the event logs. Everyone can look at the event logs, but this particular permission is required to clear the logs.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.5.2.1.11
groupRBSAdvancedAdapterConfigurationGroup has no restrictions when configuring the adapter. In addition the user is said to have administrative access to the XCC, meaning that the user can also perform the following advanced functions: firmware upgrades, PXE network boot, restore adapter factory defaults, modify and restore adapter configuration from a configuration file, and restart/reset the adapter. This excludes Server Power/Restart Control and timeout functions.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.5.2.1.12
sshClientAuth
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.1.6
sshClientAuthPubKeyTableA table that contains client authentication public key information.
SEQUENCE OF SSHClientAuthPubKeyEntry
.1.3.6.1.4.1.19046.11.1.3.1.6.1
sshClientAuthPubKeyEntryA information list about a particular SSH public key used for client authentication. The primary table index is the same value as the associated remoteAccessIdEntryIndex. The secondary table index allows selection of the Nth public key for that remoteAccessIdEntryIndex.
SSHClientAuthPubKeyEntry
.1.3.6.1.4.1.19046.11.1.3.1.6.1.1
sshClientAuthRemoteAccessIdIndexThe primary table index is the same value as the associated remoteAccessIdEntryIndex used as an index into the remoteAccessIdsTable.
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.6.1.1.1
sshClientAuthPubKeyIndexThe secondary table index used to select one of the client authentication public keys for a particular remote access Id. The index is an integer value from 1 to N where N is the number of keys associated with a particular remote access Id. An addition always causes the value of N to increase by one, effectively adding an entry after the existing keys for that remote access Id. The underlying SSH server implementation searches the keys in order from 1 to N when attempting public key authentication. NOTE:A maximum of 4 public keys can be installed for one remote access Id.
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.6.1.1.2
sshClientAuthPubKeyTypeThe type of the SSH public key represented by this entry.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.6.1.1.3
sshClientAuthPubKeySizeThe size of the SSH public key represented by this entry.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.1.6.1.1.4
sshClientAuthPubKeyFingerprintThe RSA fingerprint of the SSH public key represented by this entry. This value can be used with the SSH client to verify, on the initial connection, that the Secure Shell server responding to the request is the server running on the managed entity. This is the fingerprint of the operational host key pair. If the key pair represented by this entry is not operational then sixteen null octets must be returned.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.1.6.1.1.5
sshClientAuthPubKeyAcceptFromThis is a filter that describes the set of SSH client IP addresses and host names that can establish SSH connections to the AMM authenticated by the public key represented by this entry of the table. The filter is a comma-separated list of IP addresses and/or hostnames. A question mark may be used to match any single character. An asterisk may be used to match multiple characters. An exclamation point may preceed an IP address or hostname to deny acccess from that IP address or hostname. The format of the Accept From specification is: from=PATTERN-LIST PATTERN-LIST is the filter, which must be enclosed in double quotation marks.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.1.6.1.1.6
sshClientAuthPubKeyUnusedThe number of available storage locations that may be used to install additional Client Authentication Public Keys. This number decreases by one when a new key is added to the configuration.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.1.6.2
spClock
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.2
spClockDateAndTimeSettingDisplay XCC clock date and time setting, The format of the value is month/day/year, hour:minutes:seconds.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.2.1
spClockTimezoneSettingDisplay XCC clock Greenwich Mean Time(GMT) offset and Daylight Saving Time(DST) settings. The following table lists GMT offsets and associated DST information. DST is not observed in time zones where the 'Observe DST' value does not contain 'yes' in the table. Also, note that in some cases additional information is required to determine the clock adjustment when DST is observed. Examples -If the GMT offset is +3:30, the value is:'+3:30,no' -For Eastern Standard Time and observing DST, the value is:'-5:00,yes' -For Turkey and observing DST, the value is:'+2:00,yes,3' GMT Observe Additional Offset DST? DST value ______ _______ __________ GMT+0 yes | no GMT+1 yes | no GMT+2 yes | no When 'Observe DST?' value is 'yes': '1' Europe/Eastern Europe (ee) '3' Turkey (tky) '4' Asia/Beirut (bei) '5' Asia/Amman (amm) '6' Asia/Jerusalem (jem) GMT+3 no GMT+3:30 yes | no GMT+4 no GMT+4:30 no GMT+5 no GMT+5:30 no GMT+5:45 no GMT+6 no GMT+6:30 no GMT+7 no GMT+8 no GMT+9 no GMT+9:30 yes | no GMT+10 yes | no GMT+11 no GMT+12 yes | no GMT+13 no GMT-12 no GMT-11 yes | no GMT-10 no GMT-9 yes | no GMT-8 yes | no GMT-7 yes | no When 'Observe DST?' value is 'yes': '7' US/Mountain (mtn) '8' America/Mazatlan (maz) GMT-6 yes | no When 'Observe DST?' value is 'yes': '9' America/Mexico City (mex) '10' Canada/Central (cna) GMT-5 yes | no When 'Observe DST?' value is 'yes': '11' Cuba (cub) '12' Canada, US/East-Indiana (ein) GMT-4:30 no GMT-4 yes | no When 'Observe DST?' value is 'yes': '13' America/Asuncion (asu) '14' America/Cuiaba (cui) '15' America/Santiago (san) '16' Canada/Atlantic (cat) GMT-3:30 yes | no GMT-3 yes | no When 'Observe DST?' value is 'yes': '17' America/Gothab (gtb) '18' America/Montevideo (moo) '19' Brazil/East (bre) GMT-2 no GMT-1 yes | noro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.2.2
spIdentification
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.3
spTxtIdXCC text ID.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.3.1
spRoomIDRoom where the system is located.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.3.3.2
spRackIDID for Rack that contains this system.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.3.3.3
spRackUnitPositionPosition within the rack for this system.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.3.3.4
spRackUnitHeightNumber of rack units occupied by this system.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.3.3.5
spRackBladeBayBay number for system contained in a blade chassis.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.3.3.6
spFullPostalAddressA NULL terminated 300 byte string that contains the full postal address for this system.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.19046.11.1.3.3.7
networkConfiguration
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4
networkInterfaces
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1
ethernetInterface
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1.1
ethernetInterfaceTypeThe type of interface. Indicates 'Ethernet-1'.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.1.1.1
ethernetInterfaceEnabledDisable or enable the interface.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.1.1.2
ethernetInterfaceHostNameContains the 64 byte null terminated DNS host name for this interface.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.1.1.3
ethernetInterfaceIPAddressContains the IP address for the ethernet interface.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.1.4
ethernetInterfaceAutoNegotiateIf this is enabled, then we should ignore Speed/Duplex.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.1.1.5
ethernetInterfaceDataRateSpecifies the data transfer rate to be used over the ethernet interface 10Mb/100Mb/Auto. Note that the value of this variable is ignored if ethernetInterfaceAutoNegotiate is set to enabled(0).ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.1.1.6
ethernetInterfaceDuplexSettingSpecifies the duplex settings for the data transfer rate to be used over the ethernet interface Half/Full/Auto.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.1.1.7
ethernetInterfaceLAASpecifies the locally administered MAC address. The locally administered address must be a hexadecimal value between 000000000000 - FFFFFFFFFFFF. This value must be in the form XX:XX:XX:XX:XX:XX where 'X' is a number between 0 - 9 and A - F. This XCC subsystem does not allow use of a multicast address. A multicast address has the least significant bit of the first byte set to a 1. The first byte must, therefore, be an even number.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.1.1.8
ethernetInterfaceDhcpEnabledDisable or enable DHCP on this interface.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.1.1.9
ethernetInterfaceGatewayIPAddressContains the IP address of the gateway/router for the ethernet interface.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.1.10
ethernetInterfaceBIASpecifies the burned-in MAC (BIA) address.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.1.1.11
ethernetInterfaceMTUContains the Maximum Transmission Unit(MTU) for the ethernet interfacero
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.1.1.12
ethernetInterfaceSubnetMaskContains the Subnet Mask for the ethernet interfacero
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.1.13
dhcpEthernetInterface
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1.1.14
dhcpHostNameContains the 64 byte null terminated DNS host name for this interface, assigned by the DHCP server.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.1.1.14.1
dhcpIPAddressContains the IP address for the ehternet interface, assigned by the DHCP server.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.1.14.2
dhcpGatewayIPAddressContains the IP address of the gateway/router for the ethernet interface, assigned by the DHCP server.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.1.14.3
dhcpSubnetMaskContains the Subnet Mask for the ethernet interface, assigned by the DHCP server.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.1.14.4
dhcpDomainNameContains the 64 byte null terminated Domain Name for this interface, assigned by the DHCP server.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.1.1.14.5
dhcpPrimaryDNSServerContains the Primary DNS server, assigned by the DHCP server.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.1.14.6
dhcpSecondaryDNSServerContains the Secondary DNS server, assigned by the DHCP server.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.1.14.7
dhcpTertiaryDNSServerContains the tertiary DNS server, assigned by the DHCP server.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.1.14.8
ethernetInterfaceVlanIf this is enabled, assign VLAN ID needs to be assigned. NOTE: This is not supported on blades.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.1.1.15
ethernetInterfaceVlanIDContains the VLAN ID for the ethernet interface. NOTE: This is not supported in blades.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.1.1.16
ethernetInterfaceIPv6
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1.4
ethernetInterfaceIPv6EnabledThe current IPv6 enabled or disabled state of this XCC. NOTE: If IPv6 address(es) have been configured for one or more interfaces/protocols/services on this XCC, when you update the firmware to a level which does not support IPv6, all IPv6 connectivity will be lost, and services/interfaces for which an IPv6 address was configured may not function properly. You will be required to reconfigure these services/interfaces.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.1.4.2
ethernetInterfaceIPv6Config
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5
ethernetInterfaceIPv6LocalAddress
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.1
ethernetInterfaceIPv6LinkLocalAddressThe IPv6 link local IP address for the ethernet interface. NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'.ro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.1.1
ethernetInterfaceIPv6StaticIPConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.2
ethernetInterfaceIPv6StaticIPConfigEnabledThe IPv6 static IP address enabled or disabled state for the ethernet interface.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.2.1
ethernetInterfaceIPv6StaticIPAddressThe IPv6 static IP address for the ethernet interface. NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'.ro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.2.2
ethernetInterfaceIPv6StaticIPAddressPrefixLenThe IPv6 static IP address prefix length for the ethernet interface. NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this object has the value 0.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.2.3
ethernetInterfaceIPv6StaticIPDefaultRouteThe IPv6 static IP address default route for the ethernet interface. NOTE: If ethernetInterfaceIPv6Enabled is currently disabled, this object has the value '0:0:0:0:0:0:0:0'.ro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.2.4
ethernetInterfaceIPv6AutoIPConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3
ethernetInterfaceDHCPv6Config
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2
ethernetInterfaceDHCPv6EnabledThe DHCPv6 enabled or disabled state for the ethernet interface.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.1
ethernetInterfaceDHCPv6IPAddressThe IPv6 address for the ethernet interface, assigned by DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'.ro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.2
ethernetInterfaceDHCPv6DomainNameThe 64 byte Domain Name for the ethernet interface, assigned by the DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '(Not available)'.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.4
ethernetInterfaceDHCPv6PrimaryDNSServerThe primary DNS server, assigned by the DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'.ro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.5
ethernetInterfaceDHCPv6SecondaryDNSServerThe secondary DNS server, assigned by the DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'.ro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.6
ethernetInterfaceDHCPv6TertiaryDNSServerThe tertiary DNS server, assigned by the DHCPv6 server. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'.ro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.7
ethernetInterfaceDHCPv6ServerThe DHCPv6 server IPv6 address used to acquire the DHCP settings. NOTE: If ethernetInterfaceIPv6Enabled or ethernetInterfaceDHCPv6Enabled is disabled or if DHCPv6 server is not available, this object has the value '0:0:0:0:0:0:0:0'.ro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.2.8
ethernetInterfaceIPv6StatelessAutoConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3
ethernetInterfaceIPv6StatelessAutoConfigEnabledThe IPv6 stateless auto-configuration enabled or disabled state for the ethernet interface.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3.1
ethernetInterfaceStatelessAutoConfigAddressesTableTable of stateless Auto-Config addresses entries
SEQUENCE OF EthernetInterfaceStatelessAutoConfigAddressesEntry
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3.2
ethernetInterfaceStatelessAutoConfigAddressesEntryStateless Auto-Config address entries
EthernetInterfaceStatelessAutoConfigAddressesEntry
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3.2.1
ethernetInterfaceStatelessAutoConfigAddressesIndexIndex for stateless Auto-Config addresses. NOTE: If ethernetInterfaceIPv6StatelessAutoConfigEnabled or ethernetInterfaceIPv6Enabled is currently disabled, this object will show nothing.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3.2.1.1
ethernetInterfaceStatelessAutoConfigAddressesThe stateless Auto-Configuration IPv6 address. NOTE: If ethernetInterfaceIPv6StatelessAutoConfigEnabled or ethernetInterfaceIPv6Enabled is currently disabled, this object will show nothing.ro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3.2.1.2
ethernetInterfaceStatelessAutoConfigAddressesPrefixLenThe stateless Auto-Configration address prefix length. NOTE: If ethernetInterfaceIPv6StatelessAutoConfigEnabled or ethernetInterfaceIPv6Enabled is currently disabled, this object will show nothing.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.1.4.5.3.3.2.1.3
vlansSM
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1.5
vlansSMvlan1config
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1.5.1
vlansSMvlan1NameThe name of VLAN1, 1-64 characters.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.1.5.1.1
vlansSMvlan1vlanIdThe VLAN ID for VLAN1.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.1.5.1.2
vlansSMvlan1StateThe state of VLAN1ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.1.5.1.3
vlansSMvlan1RemoteControlThe state of the Remote Control feature for VLAN1. Note that Remote Control can only be enabled on one VLAN.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.1.5.1.4
vlansSMvlan1SSerialOverLanThe state of the Serail Over LAN feature for VLAN1. Note that Serial Over LAN can only be enabled on one VLAN.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.1.5.1.5
vlansSMvlan2config
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2
vlansSMvlan2NameThe name of VLAN1, 1-64 characters.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.1
vlansSMvlan2vlanIdThe VLAN ID for VLAN2.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.2
vlansSMvlan2StateThe state of VLAN2ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.3
vlansSMvlan2RemoteControlThe state of the Remote Control feature for VLAN2. Note that Remote Control can only be enabled on one VLAN.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.4
vlansSMvlan2SerialOverLanThe state of the Serail Over LAN feature for VLAN2. Note that Serial Over LAN can only be enabled on one VLAN.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.5
vlansSMvlan2ipv4Config
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.6
vlansSMvlan2IPv4AddressContains the IPv4 address for the VLAN2 interface.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.6.1
vlansSMvlan2IPv4GatewayContains the Gateway IPv4 address for the VLAN2 interface.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.6.2
vlansSMvlan2IPv4SubnetMaskContains the Subnet Mask for the IPv4 address for the VLAN2 interface.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.6.3
vlansSMvlan2ipv6Config
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.7
vlansSMvlan2IPv6AddressContains the IPv6 address for the VLAN2 interface.ro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.7.1
vlansSMvlan2IPv6GatewayContains the Gateway IPv6 address for the VLAN2 interface.ro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.7.2
vlansSMvlan2IPv6PrefixLengthContains the Prefix Length for the IPv6 address for the VLAN2 interface.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.7.3
vlansSMvlan2ipv4StatusRoutes
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8
vlansSMvlan2IPv4StaticRouteIP1Contains the IPv4 address for the first IPv4 static route.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8.1
vlansSMvlan2IPv4StaticRouteSM1Contains the Subnet Mask for the first IPv4 static route.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8.2
vlansSMvlan2IPv4StaticRouteIP2Contains the IPv4 address for the second IPv4 static route.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8.3
vlansSMvlan2IPv4StaticRouteSM2Contains the Subnet Mask for the second IPv4 static route.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8.4
vlansSMvlan2IPv4StaticRouteIP3Contains the IPv4 address for the third IPv4 static route.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8.5
vlansSMvlan2IPv4StaticRouteSM3Contains the Subnet Mask for the third IPv4 static route.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.8.6
vlansSMvlan2ipv6StatusRoutes
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9
vlansSMvlan2IPv6StaticRouteIP1Contains the IPv6 address for the first IPv6 static route.ro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9.1
vlansSMvlan2IPv6StaticRoutePL1Contains the Prefix Length for the first IPv6 static route.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9.2
vlansSMvlan2IPv6StaticRouteIP2Contains the IPv6 address for the second IPv6 static route.ro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9.3
vlansSMvlan2IPv6StaticRoutePL2Contains the Prefix Length for the second IPv6 static route.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9.4
vlansSMvlan2IPv6StaticRouteIP3Contains the IPv6 address for the third IPv6 static route.ro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9.5
vlansSMvlan2IPv6StaticRoutePL3Contains the Prefix Length for the third IPv6 static route.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.1.5.2.9.6
vlansSMvlanControl
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1.5.3
vlansSMvlanConfigRevertTimoutContains the VLAN Config Revert Timeout value.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.1.5.3.1
ddnsStatusDynamic DNS provides the capability for a networked device to notify a domain name server to change, in real time, the active DNS configuration of its configured hostnames, addresses or other information stored in DNS. With Dynamic DNS, host computers gain the capability to notify their respective DNS server of the IP address they have received from a DHCP server or through self-configuration.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.1.10
hostNameContains the DNS host name for this system. This object provides the exact same function as ethernetInterfaceHostNamero
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.1.11
ddnsDomainToUseThe domain name to be used with Dynamic DNS.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.1.12
domainNameThe user assigned DNS domain name.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.1.13
lanOverUSBInterface
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.1.14
xccUSBIPAddressContains the IP address for the LAN over USB of XCC.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.14.1
xccUSBSubnetMaskContains the Subnet Mask for the LAN over USB of XCC.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.14.2
osUSBIPAddressContains the IP address for the LAN over USB of OS.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.1.14.3
tcpProtocols
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2
snmpAgentConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.1
snmpSystemNameA NULL terminated 48 byte string that contains the SNMP agent name.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.1.1
snmpSystemContactA NULL terminated 48 byte string that contains the SNMP agent contact name.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.1.2
snmpSystemLocationA NULL terminated 48 byte string that contains the SNMP agent location name.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.1.3
snmpSystemAgentTrapsDisableDisable or enable SNMP V1 and V3 traps.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.1.4
snmpAgentCommunityConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.1.5
snmpCommunityEntryCommunityNameSNMP Community entry name.ro
DisplayString
.1.3.6.1.4.1.19046.11.1.3.4.2.1.5.1
snmpCommunityEntryCommunityIpAddressSNMP Community IP address or host name.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.1.5.2
snmpv3SystemAgentEnableDisable or enable the SNMPv3 agent.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.1.7
snmpAgentUserProfileConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.1.8
snmpUserProfileTableTable of SNMPv3 User Profile entries
SEQUENCE OF SnmpUserProfileEntry
.1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1
snmpUserProfileEntrySNMP User Profile entries
SnmpUserProfileEntry
.1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1.1
snmpUserProfileEntryIndexIndex for SNMPv3 Agent User Profile entry.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1.1.1
snmpUserProfileEntryAuthProtSNMPv3 User Profile entry - Authentication Protocol supported by the user.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1.1.2
snmpUserProfileEntryPrivProtSNMPv3 User Profile entry - Privacy Protocol supported by the user.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1.1.3
snmpUserProfileEntryViewTypeSNMPv3 User Profile entry - Access level (Get) of the user.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1.1.5
snmpUserProfileEntryIpAddressSNMPv3 User Profile entry - IP address or host name.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.1.8.1.1.6
dnsConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.2
dnsEnabledDisable or enable the DNS agent.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.2.1
dnsServerIPAddress1Contains the primary DNS server IP address.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.2.2.2
dnsServerIPAddress2Contains the secondary DNS server IP address.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.2.2.3
dnsServerIPAddress3Contains the tertiary DNS server IP address.ro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.2.2.4
dnsServerIPv6Address1Contains the primary IPv6 DNS server address.ro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.19046.11.1.3.4.2.2.12
dnsServerIPv6Address2Contains the secondary IPv6 DNS server address.ro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.19046.11.1.3.4.2.2.13
dnsServerIPv6Address3Contains the tertiary IPv6 DNS server address.ro
InetAddressIPv6 (INET-ADDRESS-MIB)
.1.3.6.1.4.1.19046.11.1.3.4.2.2.14
dnsPriorityTells the order host names are resolved. The options are to either first resolve with an IPv6 DNS server or to first resolve with an IPv6 DNS server.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.2.20
dnsLXCADiscoveryDisable or enable LXCA discovery using DNS SRV records.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.2.21
smtpConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.3
smtpServerNameOrIPAddressA NULL terminated 64 byte string that contains the SMTP server Host name or IP address(a.b.c.d).ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.3.1
smtpServerPortSMTP server port number.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.2.3.2
smtpServerAuthenticationEnable/disable SMTP-AUTH function.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.3.3
smtpServerAuthenticationUserSMTP authentication user namero
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.3.4
smtpServerAuthenticationMethodSMTP authentication method , support CRAM-MD5 and PLAIN onlyro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.3.6
smtpServerReversePathA NULL terminated 256 byte string that contains the SMTP Reverse Path. The user can substitute their own sender information in place of the XCC default sender information. For example xcc@mycompany.com in place of the default alertmgr@a.b.c.d.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.3.7
tcpApplicationConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.4
slpAddrTypeGet SLP address type. Note that when slpAddrType is broadast then the multicast address in slpMulticastAddt will be ignored.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.4.2
slpMulticastAddrService Locator Protocol Multicast addressro
IpAddress
.1.3.6.1.4.1.19046.11.1.3.4.2.4.3
sshServerConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.4.5
sshServerHostKeySizeThe size of the public/private host key pair. NOTE: The XCC supports only the bits1048 value.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.4.5.1
sshServerHostKeyFingerprintThe RSA fingerprint of the public part of the host key pair. This value can be used with the SSH client to verify, on the initial connection, that the Secure Shell server responding to the request is the server running on the XCC. Null Empty string if no RSA key exists.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.4.5.2
sshEnableDisable/Enable SSH.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.4.5.5
sslConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.4.6
sslEnableHTTPSforWebGet the status for web HTTPS service. To use SSL, a client web browser must be configured to use SSL3 and/or TLS. Older export-grade browsers with only SSL2 support cannot be used.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.4.6.1
sslEnableHTTPSforCIMXMLGet the status for CIM over HTTPS service.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.4.6.2
sslEnableSecureClientLDAPGet the status of the Secure LDAP Client.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.4.6.3
sslServerCertificate
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.4.6.4
sslServerCertificateStatusGet the status of the installed HTTPS certificate. 1 = Private Key and Cert/CSR not available. 2 = Private Key and Self-signed cert installed. 3 = Private Key and CA-signed cert installed. 4 = Private Key stored, CSR available for download. 5 = Private Key and Self-signed cert installed, Private Key stored, CSR available for download. 6 = Private Key and CA-signed cert installed, Private Key stored, CSR available for download.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.4.6.4.1
sslServerCertificateExpirationDateExpiration date of the installed HTTPS certificate.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.4.6.4.2
sslLDAPTrustedCertificate
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5
sslLDAPTrustedCertificate1StatusGet the status of the LDAP trusted certificate #1. 0 = certificate not installed 1 = certificate installed.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.1
sslLDAPTrustedCertificate1ExpirationDateExpiration date of the LDAP trusted certificate #1 if it is installed.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.2
sslLDAPTrustedCertificate2StatusGet the status of the LDAP trusted certificate #2. 0 = certificate not installed 1 = certificate installed.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.3
sslLDAPTrustedCertificate2ExpirationDateExpiration date of the LDAP trusted certificate #2 if it is installed..ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.4
sslLDAPTrustedCertificate3StatusGet the status of the LDAP trusted certificate #3. 0 = certificate not installed 1 = certificate installed.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.5
sslLDAPTrustedCertificate3ExpirationDateExpiration date of the LDAP trusted certificate #3 if it is installed.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.6
sslLDAPTrustedCertificate4StatusGet the status of the LDAP trusted certificate #4. 0 = certificate not installed 1 = certificate installed.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.7
sslLDAPTrustedCertificate4ExpirationDateExpiration date of the LDAP trusted certificate #4 if it is installed.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.4.6.5.8
certDomainNames
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.4.8
certDomainNameTableThis table contains certificate domain names and status.
SEQUENCE OF CertDomainNameEntry
.1.3.6.1.4.1.19046.11.1.3.4.2.4.8.1
certDomainNameEntryEach row contains a certificate domain name and status.
CertDomainNameEntry
.1.3.6.1.4.1.19046.11.1.3.4.2.4.8.1.1
certDomainNameIndexThe index number of one certificate domain name entry.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.2.4.8.1.1.1
certDomainNameThe Certificate Domain Name of one certificate domain name entry.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.4.8.1.1.2
certDomainNameStatusThe status of the Certificate Domain Name entry.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.4.8.1.1.3
skrServers
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.4.9
skrServerTableThis table contains Storage Key Repository Server hostnames and ports.
SEQUENCE OF SkrServerEntry
.1.3.6.1.4.1.19046.11.1.3.4.2.4.9.1
skrServerEntryEach row contains a Storage Key Repository Server hostname and port.
SkrServerEntry
.1.3.6.1.4.1.19046.11.1.3.4.2.4.9.1.1
skrServerIndexThe index number of one Storage Key Repository Server entry.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.2.4.9.1.1.1
skrServerHostnameStorage Key Repository Server hostname or IP address.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.4.9.1.1.2
skrServerPortStorage Key Repository Server port number.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.2.4.9.1.1.3
skrDeviceGroupAn optional NULL terminated 16 character string that contains the Device Group that the server drives belong to.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.4.9.3
skrClientConfigCertficate
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.4.9.4
skrClientCertificateStatusGet the status of the installed Web certificates. 1 = Private Key and Cert/CSR not available. 2 = Private Key and Self-signed cert installed. 3 = Private Key and CA-signed cert installed. 4 = Private Key stored, CSR available for download. 5 = Private Key and Self-signed cert installed, Private Key stored, CSR available for download. 6 = Private Key and CA-signed cert installed, Private Key stored, CSR available for download.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.4.9.4.3
skrClientCertificateExpirationDateExpiration date of the SKR client certificate.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.4.9.4.4
skrServerCertificateExpirationDateExpiration date of the SKR Server certificate.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.4.9.12
tcpPortAssignmentCfg
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.5
httpPortAssignmentHTTP port number. Default value is 80. Once changed, the url's have to include :port at the end.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.2.5.2
httpsPortAssignmentSSL port number. Default value is 443. Once changed, the url's have to include :port at the end.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.2.5.3
sshLegacyCLIPortAssignmentSSH port number. Default value is 22.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.2.5.6
snmpAgentPortAssignmentSNMP Agent port number. Default value is 161.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.2.5.8
snmpTrapsPortAssignmentSNMP Traps port number. Default value is 162.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.2.5.9
remvidPortAssignmentRemote Console port number. Default value is 3900.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.2.5.10
cimOverHttpPortAssignmentCIM over Http port number.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.2.5.11
cimOverHttpsPortAssignmentCIM over Https port number.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.2.5.12
ldapClientCfg
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.6
ldapServer1NameOrIPAddressA NULL terminated 64 byte string that contains the LDAP server host name or IP address (a.b.c.d).ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.6.1
ldapServer1PortNumberLDAP server port number.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.2.6.2
ldapServer2NameOrIPAddressA NULL terminated 64 byte string that contains the LDAP server host name or IP address (a.b.c.d).ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.6.3
ldapServer2PortNumberLDAP server port number.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.2.6.4
ldapServer3NameOrIPAddressA NULL terminated 64 byte string that contains the LDAP server host name or IP address (a.b.c.d).ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.6.5
ldapServer3PortNumberLDAP server port number.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.2.6.6
ldapServer4NameOrIPAddressA NULL terminated 64 byte string that contains the LDAP server host name or IP address (a.b.c.d).ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.6.7
ldapServer4PortNumberLDAP server port number.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.2.6.8
ldapRootDNDistinguished Name for root entry of directory tree. An example might look like dn=foobar,dn=com.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.6.9
ldapGroupFilterThis filter is used for group authentication. It specifies what group or groups that this MM belongs to. If left blank, group authentication is disabled. Otherwise, group authentication will be performed against the filter. The filter can be a specific group name (eg. IMMWest), a wildcard (*) which matches everything, or a wildcard with a prefix (eg. XCC*). The default filter is XCC*. After user authentication, group authentication will take place, whereby an attempt will be made to match the group or groups (that the user belongs to) to the group filter defined here. If there is no match, the user will not pass authentication and will be blocked. If there is a match, the login permissions for the user will be retrieved from the matched group(s), unless the user already has login permissions assigned directly from the user record retrieved from the LDAP server.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.6.11
ldapBindingMethodOn initial binds to the LDAP server during user authentication, there are three options: Anonymous authentication: Bind attempt is made without a client DN or password. If the bind is successful, a search will be requested in order to find an entry on the LDAP server for the user attempting to login. If an entry is found, a second attempt to bind will be attempted, this time with the user's DN and password. If this succeeds, the user is deemed to have passed the user authentication phase. Group authentication is then attempted if it is enabled. Client authentication: Bind attempt is made with client DN and password specified by this configuration parameter. If the bind is successful, we proceed as above. User Principal Name (UPN): Bind attempt is made directly with the credentials used during the login process. If this succeeds, the user is deemed to have passed the user authentication phase. Note that for Active Directory servers, the userid can have the form someuser@somedomain or simply someuser.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.6.12
ldapClientAuthenticationDNThe initial bind to the LDAP server during user authentication can be performed with anonymous authentication, client based authentication, or UPN. The client based option requires a client DN and password as parameters to the bind request. These parameters are configured here. Note that the password can be left blank.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.6.13
ldapRoleBasedSecurityEnabledA value of true for RoleBasedSecurityEnabled indicates enhanced will be used by the service processor. A value of false for RoleBasedSecurityEnabled indicates the legacy bit mask based security is being used.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.6.15
ldapServerTargetNameWhen administrator chooses Enhanced Role Based Security authentication model, he can associate one XCC with one managed target object in Snap-in (one tool to configure LDAP users permission) via one target name. The XCC target name can be looked as alias of XCC, administrator can change it according to his configuration requirements. This is a string of up to 63 characters (plus the null character)ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.6.16
ldapUIDsearchAttributeWhen the binding method selected is Anonymous authentication or Client authentication, the initial bind to the LDAP server is followed by a search request aimed at retrieving specific information about the user, including the user's DN, login permissions, and group ownerships. In order to retrieve this information, the search request must specify the attribute name used to represent userids on that server. Specifically, this name is used as a search filter against the login id entered by the user. This attribute name is configured here. If this field is left blank, a default of uid is used during user authentication. For example, on Active Directory servers, the attribute name used for userids is often sAMAccoutName. When the binding method selected is UPN or Strict UPN, this field defaults automatically to userPrincipalName during user authentication if the userid entered has the form userid@somedomain.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.6.17
ldapGroupSearchAttributeWhen the MM Group Filter name is configured, it is necessary to retrieve from the LDAP server the list of groups that a particular user belongs to. This is required to do group authentication. In order to retrieve this list, the search filter sent to the server must specify the attribute name associated with groups. This field specifies this attribute name. If this field is left blank, the attribute name in the filter will default to memberOf.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.6.18
ldapLoginPermissionAttributeWhen a user successfully authenticates via a LDAP server, it is necessary to retrieve the login permissions for this user. In order to retrieve these permissions, the search filter sent to the server must specify the attribute name associated with login permissions. This field specifies this attribute name.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.6.19
ldapUseDNSOrPreConfiguredServersThe MM contains a Version 2.0 LDAP Client that may be configured to provide user authentication through one or more LDAP servers. The LDAP server(s) to be used for authentication can be discovered dynamically or manually pre-configured. If the usePreConfiguredLDAPServers option is selected, up to 3 LDAP servers can be configured. Simply enter the server's IP address or hostname (assuming DNS is enabled). The port number for each server is optional. If left blank, the default value of 389 is used for non-secured LDAP connections. For secured connections, the default is 636. At least one server must be configured. If the useDNSToFindLDAPServers is selected, the mechanisms described by RFC2782 (A DNS RR for specifying the location of services) are applied to find the server(s). This is known as DNS SRV.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.6.20
ldapDomainSourceThe DNS SRV request sent to the DNS server must specify a domain name. The LDAP client will determine where to get this domain name based on one of the following three options: - extractSearchDomainFromLoginID: With this option, the LDAP client will use the domain name in the login id. For example, if the login id is joesmith@mycompany.com, the domain name equals mycompany.com. If the domain name cannot be extracted, the DNS SRV will fail, causing the user authentication to fail automatically. - useOnlyConfiguredSearchDomainBelow: With this option, the LDAP client will use the domain name configured in the Search Domain parameter. - tryLoginFirstThenConfiguredValue: With this option, the LDAP client will first attempt to extract the domain name from the login id. If this succeeds, this domain name will be used in the DNS SRV request. If there is no domain name present in the login id, the LDAP client will instead use the configured Search Domain parameter as the domain name in the DNS SRV request. If nothing is configured, user authentication will fail immediately.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.6.21
ldapForestNameIn order to discover Global Catalogs (GC), the forest name must be configured in the ForestName property. The Global Catalogs are required for users who belong to universal groups in cross-domains. In environments where cross-domain group membership does not apply, this field can be left blank.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.6.22
ldapAuthCfgIf ldapAuthCfg is set to 0, LDAP server is used to authenticate and authorize users. If it is set to 1, LDAP server is only used to authenticate users. Note:LDAP Authentication Only mode is currently supported only in an Active Directory environment.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.6.23
ldapSearchDomainThis parameter may be used as the domain name in the DNS SRV request, depending on how the Domain Source parameter is configured.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.6.24
ldapServiceNameThe DNS SRV request sent to the DNS server must also specify a service name. The configured value will be used for this purpose. If left blank, the default value used is 'ldap'. Note that the DNS SRV request must also specify a protocol name. This defaults to 'tcp' and is not configurable.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.6.25
ntpConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.8
ntpEnableDisable/Enable the NTP client. The client will update the XCC system clock at the frequency specified.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.8.1
ntpIpAddressHostname1First NTP server's IP address or hostname if DNS is enabled and configured.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.8.2
ntpUpdateFrequencyThe frequency in minutes that the NTP service runs. The value range is 3 to 1440.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.3.4.2.8.3
ntpIpAddressHostname2Second NTP server's IP address or hostname if DNS is enabled and configured.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.8.4
ntpIpAddressHostname3Third NTP server's IP address or hostname if DNS is enabled and configured.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.8.6
ntpIpAddressHostname4Fourth NTP server's IP address or hostname if DNS is enabled and configured.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.3.4.2.8.7
ipmiConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.10
ipmiStatusGet the status of IPMI servicero
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.10.1
cimxmlConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.11
cimxmlStatusGet the status of CIM service.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.11.1
restConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.3.4.2.12
restStatusGet the status of the REST over HTTPS.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.4.2.12.1
xccVersionCheckGet the XCC version type.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.3.7
generalSystemSettings
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.4
serverTimers
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.4.1
oSHangNumber, in 1 second intervals, the XCC will check to insure the OS is operating properly. If the operating system fails to respond within 6 seconds to one of these checks, the remote supervisor adapter will generate an O/S Timeout alert(if enabled) and automatically restart the system one time. Once the system is restarted, the O/S Watchdog is automatically disabled until the operating system is shutdown and the server is power cycled.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.4.1.1
oSLoaderNumber in 30 second intervals the remote XCC will wait between completion of POST and the end of loading the OS. If this interval is exceeded, the XCC will generate a Loader Timeout alert(if enabled) and automatically restart the system one time. Once the system is restarted, the Loader Timeout is automatically disabled until the operating system is shutdown and the server is power cycled.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.4.1.2
networkPXEbootModify the system's boot sequence for the next system restart in order to attempt a PXE/DHCP network boot. The system's boot sequence(set via the BIOS settings) will be altered only if the system is not under PAP (Privileged Access Protection).ro
Enumeration
.1.3.6.1.4.1.19046.11.1.4.2
systemPower
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.5
powerStatistics
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.5.1
currentSysPowerStatusIndicates if the system is currently powered on, off, or in sleep state.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.5.1.1
powerOnHoursNumber of hours the system has been powered on.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.5.1.2
restartCountNumber of times the system has been restarted.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.5.1.3
systemStateShows the current operational state of the system.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.5.1.4
powerSysConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.5.2
powerSysOffDelayThe number of 1 second interval the XCC will wait before powering off the system.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.5.2.1
powerSysOnClockSettingThe clock setting used to determine when the XCC will power on the system. For example the value '03/04/2001,06:00' means that the system will power on March 4, 2001 at 06:00AM.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.5.2.2
powerCyclingSchedule
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.5.5
schedulePowerOffWithOsShutdownPower Off the system after performing a OS shutdown at specified time and day of the week. Example: Monday,09:00, To reset, the value as Never,00:00.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.5.5.1
schedulePowerOnSystemPower On the system at specified time and day of the week. Example: Monday,09:00. To reset, the value as Never,00:00.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.5.5.2
serviceAdvisor
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.8
autoCallHomeSetup
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.8.1
acceptLicenseAgreementAccept Terms and Conditions of Service Advisor. The user will have to accept the terms and conditions before Service Advisor can send diagnostic data to support personnel. If XCC configuration is reset to defaults, the user will have to accept the terms and conditions again before they can enable Service Advisor. For more information, please refer to the BladeCenter User's Guide. It will return disabled(0) or enabled(1), depending upon the current state.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.8.1.1
serviceAdvisorEnableDisable/Enable Call Home Support. The User Agreement must be accepted and the contact information must be set before the Call Home Support function of Service Advisor can be enabled.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.8.1.2
serviceSupportCenter
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.8.2
lenovoSupportCenterThe country code for the Support Center. 2 character ISO country code.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.2.1
contactInformation
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.8.3
companyNameThe organization/company name of the contact person. 1-30 characters.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.3.1
contactNameThe name of the contact person.1-30 characters.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.3.2
phoneNumberThe phone of the contact person. 5-30 characters.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.3.3
emailAddressThe email of the contact person. It must contain '@' and dot '.' in form userid@hostname (30 characters maximum). The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters. The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items. Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.3.4
addressThe address of the machine location. The information in this field should be of sufficient detail to allow someone to quickly find the chassis when necessary. 1-30 characters.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.3.5
cityThe city of the machine location. 1-30 characters.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.3.6
stateThe state of the machine location. 2-3 characters.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.3.7
postalCodeThe postal code of the location for this system. 1-9 characters, only alphanumeric characters are valid.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.3.8
phoneExtensionThe phone extension of the contact person. 30 characters maximum.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.3.9
altContactNameThe name of the alternate contact person. 1-30 characters.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.3.10
altPhoneNumberThe phone of the alternate contact person. 5-30 characters.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.3.11
altPhoneExtensionThe phone extension of the alternate contact person. 30 characters maximum.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.3.12
altEmailAddressThe email of the alternate contact person. It must contain '@' and dot '.' in form userid@hostname (30 characters maximum). The userid can be alphanumeric characters, '.', '-', or '_' but must begin and end with alphanumeric characters. The hostname can be alphanumeric characters, '.', '-', or '_'. It must contain at least two domain items. Every domain item should begin and end with alphanumeric character, and the last domain item should be 2-20 alphabetic characters.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.3.13
machineLocationPhoneNumberThe phone of the physical location where the compuer system resides. 5-30 characters.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.3.14
httpProxyConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.8.4
httpProxyEnableDisable/Enable of the HTTP Proxy. HTTP Proxy is used by the XCC when it is not connected to the internet directly.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.8.4.1
httpProxyLocationFully qualified host name or IP address of the HTTP Proxy. Maximum of 63 characters.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.4.2
httpProxyPortThe port number of the HTTP Proxy. An integer value from 1 to 65535.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.8.4.3
httpProxyUserNameUser Name of the HTTP Proxy. A maximum of 30 characters string without spaces.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.4.4
httpProxyPasswordPassword of the HTTP Proxy. A maximum of 15 characters string without spaces.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.4.5
activityLogs
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.8.5
activityLogTableTable of Service Advisor Activity Log entries information. This table displays events that were generated by the system or user that are called home. The entries are displayed in reverse chronological order (most recent call home entry first). For any events that happen with same Date/Time, only one event will be called home. If a call home event that is already in the activity log is triggered again on the same event source, it will not be called home again unless the prior entry has been acknowledged as corrected or, in the case of XCC, 120 hours (5 days) have passed since it initially occurred and was called home.
SEQUENCE OF ActivityLogEntry
.1.3.6.1.4.1.19046.11.1.8.5.1
activityLogEntryActivity Log table entry. Each entry has the result of the call-home attempt, the service number assigned for the issue by the Support Center, the event ID, event source, date and time that event occured, and a text message.
ActivityLogEntry
.1.3.6.1.4.1.19046.11.1.8.5.1.1
activityLogIndexThe Activity Log index number. For consistent results, view as a table and not as individual entries.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.8.5.1.1.1
activityLogStringA string of data detailing one Activity Log entry. The text message is from the original entry in the event log. For consistent results, view as a table and not as individual entries.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.5.1.1.2
activityLogAcknowledgeThe acknowledgement of one Activity Log entry as corrected. This field allows the users to set a reminder next to certain events to indicate their awareness of the issue. Checking the acknowledge flag will not cause the event to be removed from the log or close the ticket at the Support Center. This log is not cleared, so the acknowledge flag can be used to indicate a problem can be ignored. This field can be also used to override the 120 hour (5 day) filtering of reports via the Support Center or FTP/TFTP Server of Service Data. For consistent results, view as a table and not as individual entries.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.8.5.1.1.3
activityLogAttributeA string of data detailing one Activity Log entry's attribute. It contains states of both calling the Support Center and FTP/TFTP Server. A PENDING indicates that the system is preparing for the event to be called home by collecting data about the systems state. A SUCCESS state indicates that the problem was successfully transmitted to the Support Center or FTP/TFTP Server. A DISABLED state indicates that Service Advisor has disabled calling the Support Center or FTP/TFTP Server while the hardware event is detected. A NOT SENT state indicates that the serviceable event was not sent to prevent the same event from being sent repeatedly. The FAILED state indicates that the attempt to transmit the event information was not successful. Additional information may be found in the Event Log. The service number is similar to a ticket number that can be used as a reference to the issue reported by the machine when contacting the Support Center. The event ID, event source, date and time are all information from the original entry in the event log. The acknowledged as corrected field is a reminder to certain events to indicate their awareness of the issue. For consistent results, view as a table and not as individual entries.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.5.1.1.4
autoFTPSetup
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.8.6
autoFTPCallModeThis field specifies the automated problem reporting mode. Automated problem reporting mode allows the XCC to automatically put service data to a specified server when a call home event is detected. For any call home events that happen with same Date/Time, only one event will be reported. The system will also wait for an interval of 120 hours (5 days) before another identical event can be sent for the same failed component.ro
Enumeration
.1.3.6.1.4.1.19046.11.1.8.6.1
autoFTPCallAddrThis field specifies the remote server address of FTP and TFTP. It should be fully qualified hostname or IP address.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.6.2
autoFTPCallPortThis field specifies the port on remote FTP/TFTP server for data transmission.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.8.6.3
autoFTPCallUserIDThis field specifies the user account to login remote FTP server.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.6.4
callHomeExclusionEvents
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.8.7
readCallHomeExclusionEventTableTable of Call Home Exclusion Event entries information.
SEQUENCE OF ReadCallHomeExclusionEventEntry
.1.3.6.1.4.1.19046.11.1.8.7.1
readCallHomeExclusionEventEntryCall Home Exclusion Event table entry
ReadCallHomeExclusionEventEntry
.1.3.6.1.4.1.19046.11.1.8.7.1.1
readCallHomeExclusionEventIndexThe index number of one Call Home Exclusion Event. For consistent results, view as a table and not as individual entries.ro
INTEGER
.1.3.6.1.4.1.19046.11.1.8.7.1.1.1
readCallHomeExclusionEventIDThe Event ID of one Call Home Exclusion Event entry. For consistent results, view as a table and not as individual entries.ro
OCTET STRING
.1.3.6.1.4.1.19046.11.1.8.7.1.1.2
supportProcessor
OBJECT IDENTIFIER
.1.3.6.1.4.1.19046.11.1.158