LENOVO-XCC-ALERT-MIB
AI MIB Summary
The LENOVO-XCC-ALERT-MIB enables Lenovo XCC management firmware to generate SNMP traps for critical hardware and system alert conditions. This module facilitates real-time monitoring of server health events, including component failures, environmental thresholds, and security incidents, by transmitting standardized alert notifications to network management systems.
This MIB is used by the XCC to define traps for Alert conditions detected by the management firmware.
Main OID:
lenovoXCCAlertMIB.1.3.6.1.4.1.19046.11.1.158.5
55
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
55 total| Object Name |
|---|
lenovoXCCAlertMIBThis MIB is used by the XCC to define traps for Alert conditions detected by the management firmware. MODULE-IDENTITY .1.3.6.1.4.1.19046.11.1.158.5 |
IMPORTSThis MIB is used by the XCC to define traps for Alert conditions detected by the management firmware. Unknown .1.3.6.1.4.1.19046.11.1.158.5 |
lenovoSpTrapTempCCritical Alert: Temperature threshold exceeded. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.0 |
lenovoSpTrapVoltCCritical Alert: Voltage threshold exceeded. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.1 |
lenovoSpTrapPowerCCritical Alert: Power failure. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.4 |
lenovoSpTrapHdCCritical Alert: Hard disk drive failure. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.5 |
lenovoSpTrapRdpsCCritical Alert: Redundant Power Supply failure. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.9 |
lenovoSpTrapRdpsNNon-Critical Alert: Redundant Power Supply failure. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.10 |
lenovoSpTrapFanCCritical Alert: Single Fan failure. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.11 |
lenovoSpTrapTempNNon-Critical Alert: Temperature threshold exceeded. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.12 |
lenovoSpTrapVoltNNon-Critical Alert: Voltage threshold exceeded. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.13 |
lenovoSpTrapOsToSSystem Alert: OS Timeout value exceeded. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.21 |
lenovoSpTrapAppSSystem Alert: Application Alert. Refer to Message ID for specific condition. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.22 |
lenovoSpTrapPoffSSystem Alert: Power Off. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.23 |
lenovoSpTrapPonSSystem Alert: Power On. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.24 |
lenovoSpTrapBootSSystem Alert: System Boot Failure. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.25 |
lenovoSpTrapLdrToSSystem Alert: OS Loader Timeout. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.26 |
lenovoSpTrapPFASSystem Alert: Predictive Failure Analysis(PFA) information. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.27 |
lenovoSpTrapRLoginSev-Off Alert: Event Remote Login. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.30 |
lenovoSpTrapSysLogSSystem Alert: System Log 75% full. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.35 |
lenovoSpTrapIhcCCritical Alert: Incompatible hardware configuration. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.36 |
lenovoSpTrapNwChangeSSystem Alert: Network change notification. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.37 |
lenovoSpTrapCPUCCritical Alert: CPU Error. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.40 |
lenovoSpTrapMemoryCCritical Alert: Memory Error. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.41 |
lenovoSpTrapCPUNNon-Critical Alert: CPU Error. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.42 |
lenovoSpTrapMemoryNNon-Critical Alert: Memory Error. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.43 |
lenovoSpTrapHardwareCCritical Alert: Other Failure - refer to Message ID for specific condition. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.50 |
lenovoSpTrapHardwareNNon-Critical Alert: Warning - refer to Message ID for specific condition. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.60 |
lenovoSpTrapPowerNNon-Critical Alert: Power. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.164 |
lenovoSpTrapFanNNon-Critical Alert: Fan Error. TRAP-TYPE .1.3.6.1.4.1.19046.11.1.158.5.0.165 |
xcctrapg OBJECT IDENTIFIER .1.3.6.1.4.1.19046.11.1.158.5.1 |
altDateTimeTimestamp of Local Date and Time when alert was generatedro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.1 |
altSpTxtIdSP System Identification - Text Identificationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.3 |
altSysUuidHost System UUID(Universal Unique ID)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.5 |
altSysSernHost System Serial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.6 |
altPriorityAlert Severity Value
- Critical Alert(0)
- Non-Critical Alert(2)
- System Alert(4)
- Recovery(8)ro INTEGER .1.3.6.1.4.1.19046.11.1.158.5.1.8 |
altMsgTextAlert Message Textro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.9 |
altMsgIDAlert Message IDro INTEGER .1.3.6.1.4.1.19046.11.1.158.5.1.10 |
altMsgIDPrefixAlert Message IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.11 |
altHostContactHost Contactro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.12 |
altHostLocationHost Locationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.13 |
altHostRoomIDHost Location - Room IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.14 |
altHostRackIDHost Location - Rack IDro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.15 |
altHostLowestUposHost Location - Lowest U-positionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.16 |
altHostBladeBayHost Location - BladeBayro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.17 |
altEventIDEvent Identifierro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.18 |
altServiceableServiceability information.ro Enumeration .1.3.6.1.4.1.19046.11.1.158.5.1.19 |
altTestThis event generated for test purposes.ro Enumeration .1.3.6.1.4.1.19046.11.1.158.5.1.20 |
altFailingFRUsOrdered list of Failing FRU Numbers, separated by commas.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.21 |
altHostMTMMachine Type and Model for failing host.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.22 |
altAuxDataAuxiliary data that may be included for some events.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.23 |
altCommonEventIDCommon Event Identifierro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.24 |
altEventTypeThe type of eventro INTEGER .1.3.6.1.4.1.19046.11.1.158.5.1.25 |
altDetectorIDReporting source of eventro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.26 |
altDIMMPartNumberReporting DIMM part number informationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.19046.11.1.158.5.1.27 |