LENOVO-ENV-MIB
AI MIB Summary
The LENOVO-ENV-MIB module enables SNMP-based monitoring of hardware environmental conditions on Lenovo servers and storage systems, specifically tracking critical metrics such as temperature, fan speeds, and voltage levels to trigger alert notifications for thermal or power anomalies.
Defines environmental notifications
Main OID:
lenovoEnvMIB.1.3.6.1.4.1.19046.2.3.11
42
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
42 total| Object Name |
|---|
lenovoEnvMIBDefines environmental notifications MODULE-IDENTITY .1.3.6.1.4.1.19046.2.3.11 |
lenovoEnvMibObjects OBJECT IDENTIFIER .1.3.6.1.4.1.19046.2.3.11.1 |
lenovoEnvMibPowerSupplyTableThis table contains information for the various power supplies in the switch. SEQUENCE OF LenovoEnvMibPowerSupplyEntry .1.3.6.1.4.1.19046.2.3.11.1.1 |
lenovoEnvMibPowerSupplyEntryA single row containing information for a power supply. The power supply description and name are derived from values in the Entity MIB. Row is indexed using the same index used by the Physical Table of the Entity MIB LenovoEnvMibPowerSupplyEntry .1.3.6.1.4.1.19046.2.3.11.1.1.1 |
lenovoEnvMibPowerSupplyIndexIndex of entry for power supply in Physical Table of Entity MIBro PhysicalIndex (ENTITY-MIB) .1.3.6.1.4.1.19046.2.3.11.1.1.1.1 |
lenovoEnvMibPowerSupplyIDID of power supplyro Integer32 .1.3.6.1.4.1.19046.2.3.11.1.1.1.2 |
lenovoEnvMibPowerSupplyDescDescription of power supplyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.19046.2.3.11.1.1.1.3 |
lenovoEnvMibPowerSupplyNameName of power supplyro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.19046.2.3.11.1.1.1.4 |
lenovoEnvMibPowerSupplyStateState of the power supplyro LenovoEnvMibPowerSupplyState .1.3.6.1.4.1.19046.2.3.11.1.1.1.5 |
lenovoEnvMibFanTableThis table contains information for the various fans in the switch. SEQUENCE OF LenovoEnvMibFanEntry .1.3.6.1.4.1.19046.2.3.11.1.2 |
lenovoEnvMibFanEntryA single row containing information for a fan. The fan description and name are derived from values in the Entity MIB. Row is indexed using the same index used by the Physical Table of the Entity MIB LenovoEnvMibFanEntry .1.3.6.1.4.1.19046.2.3.11.1.2.1 |
lenovoEnvMibFanIndexIndex of entry for fan in Physical Table of Entity MIBro PhysicalIndex (ENTITY-MIB) .1.3.6.1.4.1.19046.2.3.11.1.2.1.1 |
lenovoEnvMibFanIDID of fanro Integer32 .1.3.6.1.4.1.19046.2.3.11.1.2.1.2 |
lenovoEnvMibFanDescDescription of fanro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.19046.2.3.11.1.2.1.3 |
lenovoEnvMibFanNameName of fanro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.19046.2.3.11.1.2.1.4 |
lenovoEnvMibFanStateState of the fanro LenovoEnvMibFanState .1.3.6.1.4.1.19046.2.3.11.1.2.1.5 |
lenovoEnvMibFanAirFlowAirflow direction of the fanro LenovoEnvMibFanAirFlow .1.3.6.1.4.1.19046.2.3.11.1.2.1.6 |
lenovoEnvMibFanModuleModule number of the fanro Integer32 .1.3.6.1.4.1.19046.2.3.11.1.2.1.7 |
lenovoEnvMibFanSpeedRPMSpeed of the fan in revolutions per minute (RPM)ro Integer32 .1.3.6.1.4.1.19046.2.3.11.1.2.1.8 |
lenovoEnvMibFanSpeedPercentSpeed of the fan as a percentagero Gauge32 .1.3.6.1.4.1.19046.2.3.11.1.2.1.9 |
lenovoEnvMibTempSensorTableThis table contains information for the various temperature sensors in the switch. SEQUENCE OF LenovoEnvMibTempSensorEntry .1.3.6.1.4.1.19046.2.3.11.1.3 |
lenovoEnvMibTempSensorEntryA single row containing information for a temperature sensor. The temperature sensor description and name are derived from values in the Entity MIB. Row is indexed using the same index used by the Physical Table of the Entity MIB LenovoEnvMibTempSensorEntry .1.3.6.1.4.1.19046.2.3.11.1.3.1 |
lenovoEnvMibTempSensorIndexIndex of entry for temperature sensor in Physical Table of Entity MIBro PhysicalIndex (ENTITY-MIB) .1.3.6.1.4.1.19046.2.3.11.1.3.1.1 |
lenovoEnvMibTempSensorIDID of temperature sensorro Integer32 .1.3.6.1.4.1.19046.2.3.11.1.3.1.2 |
lenovoEnvMibTempSensorDescDescription of temperature sensorro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.19046.2.3.11.1.3.1.3 |
lenovoEnvMibTempSensorNameName of temperature sensorro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.19046.2.3.11.1.3.1.4 |
lenovoEnvMibTempSensorStateState of the temperature sensorro LenovoEnvMibTempSensorState .1.3.6.1.4.1.19046.2.3.11.1.3.1.5 |
lenovoEnvMibTempSensorTemperatureTemperature of the sensor in Celciusro Integer32 .1.3.6.1.4.1.19046.2.3.11.1.3.1.6 |
lenovoEnvMibTempSensorThresholds OBJECT IDENTIFIER .1.3.6.1.4.1.19046.2.3.11.1.4 |
lenovoEnvMIBTempSensorWarningSystem temperature sensor warning threshold valuero Integer32 .1.3.6.1.4.1.19046.2.3.11.1.4.1 |
lenovoEnvMIBTempSensorShutdownSystem temperature sensor shutdown/failure threshold valuero Integer32 .1.3.6.1.4.1.19046.2.3.11.1.4.2 |
lenovoEnvMIBTempSensorSetPointSystem temperature sensor set point threshold valuero Integer32 .1.3.6.1.4.1.19046.2.3.11.1.4.3 |
lenovoEnvMibNotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.19046.2.3.11.3 |
lenovoEnvMibNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.19046.2.3.11.3.0 |
lenovoEnvMibPowerSupplyFailureThis trap signifies that a power supply has failed. NOTIFICATION-TYPE .1.3.6.1.4.1.19046.2.3.11.3.0.1 |
lenovoEnvMibPowerSupplyFixedThis trap signifies that a power supply has been restored. NOTIFICATION-TYPE .1.3.6.1.4.1.19046.2.3.11.3.0.2 |
lenovoEnvMibFanFailureThis trap signifies that a fan has failed. NOTIFICATION-TYPE .1.3.6.1.4.1.19046.2.3.11.3.0.3 |
lenovoEnvMibFanFixedThis trap signifies that a fan has been restored. NOTIFICATION-TYPE .1.3.6.1.4.1.19046.2.3.11.3.0.4 |
lenovoEnvMibTempSensorFailureThis trap signifies that a temperature sensor has failed. NOTIFICATION-TYPE .1.3.6.1.4.1.19046.2.3.11.3.0.5 |
lenovoEnvMibTempSensorFixedThis trap signifies that a temperature sensor has been restored. NOTIFICATION-TYPE .1.3.6.1.4.1.19046.2.3.11.3.0.6 |
lenovoEnvMibNotificationObjects OBJECT IDENTIFIER .1.3.6.1.4.1.19046.2.3.11.3.1 |
lenovoEnvMibTempSensorThresholdThreshold that was crossed that generated the notificationro LenovoEnvMibTempSensorThreshold .1.3.6.1.4.1.19046.2.3.11.3.1.1 |