Juniper-FRAME-RELAY-MIB
AI MIB Summary
The Juniper-FRAME-RELAY-MIB enables monitoring of Frame Relay virtual circuit states, interface statistics, and DLCI (Data Link Connection Identifier) configurations on Juniper Networks routers. It provides access to critical performance counters and error metrics, such as FECN/BECN flags, CIR (Committed Information Rate) parameters, and PVC (Permanent Virtual Circuit) status, for managing legacy WAN connectivity.
The Frame Relay MIB for the Juniper Networks enterprise.
Main OID:
juniFrameRelayMIB.1.3.6.1.4.1.4874.2.2.10
105
Objects
Active
Status
7
Dependencies
Imported Objects
Objects
105 total| Object Name |
|---|
juniFrameRelayMIBThe Frame Relay MIB for the Juniper Networks enterprise. MODULE-IDENTITY .1.3.6.1.4.1.4874.2.2.10 |
juniFrObjects OBJECT IDENTIFIER .1.3.6.1.4.1.4874.2.2.10.1 |
juniFrIfLayer OBJECT IDENTIFIER .1.3.6.1.4.1.4874.2.2.10.1.1 |
juniFrNextIfIndexCoordinate ifIndex value allocation for entries in juniFrDlcmiTable.
A GET of this object returns the next available ifIndex value to be used
to create an entry in the associated interface table; or zero, if no
valid ifIndex value is available. This object also returns a value of
zero when it is the lexicographic successor of a varbind presented in an
SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
that ifIndex allocation is unintended.
Successive GETs will typically return different values, thus avoiding
collisions among cooperating management clients seeking to create table
entries simultaneously.ro JuniNextIfIndex (Juniper-TC) .1.3.6.1.4.1.4874.2.2.10.1.1.1 |
juniFrDlcmiTableThe Parameters for the Data Link Connection Management Interface for
the frame relay service on this interface.
This table represents a superset of functionality specified in the
FRAME-RELAY-DTE-MIB. In particular, it adds attributes that permit the
interface to operate as a network-side (DCE) interface. SEQUENCE OF JuniFrDlcmiEntry .1.3.6.1.4.1.4874.2.2.10.1.1.2 |
juniFrDlcmiEntryThe Parameters for a particular Data Link Connection Management
Interface.
Creating/deleting entries in this table causes corresponding entries for
be created/deleted in ifTable/ifXTable/juniIfTable, and
juniFrDlcmiStatsTable.
Creating/deleting user-side (DTE) entries in this table also causes
coresponding entries to be created/deleted in
FRAME-RELAY-DTE-MIB.frDlcmiTable.
The organization and definitions of objects in this table are
intentionally aligned closely to those in FRAME-RELAY-DTE-MIB. JuniFrDlcmiEntry .1.3.6.1.4.1.4874.2.2.10.1.1.2.1 |
juniFrDlcmiIfIndexThe ifIndex value of the corresponding ifEntry.ro InterfaceIndex (IF-MIB) .1.3.6.1.4.1.4874.2.2.10.1.1.2.1.1 |
juniFrDlcmiStateThis variable states which Data Link Connection Management scheme is
active (and by implication, what DLCI it uses) on the Frame Relay
interface.rw Enumeration .1.3.6.1.4.1.4874.2.2.10.1.1.2.1.2 |
juniFrDlcmiAddressThis variable states which address format is in use on the Frame Relay
interface.rw Enumeration .1.3.6.1.4.1.4874.2.2.10.1.1.2.1.3 |
juniFrDlcmiAddressLenThis variable states the address length in octets. In the case of Q922
format, the length indicates the entire length of the address including
the control portion.rw Enumeration .1.3.6.1.4.1.4874.2.2.10.1.1.2.1.4 |
juniFrDlcmiPollingIntervalThis is the number of seconds between successive status enquiry
messages sent by the DTE.
Pertains to DTE/NNI operation only. This parameter can be reconfigured
only when the Frame Relay interface is acting as a DTE or NNI.rw Integer32 .1.3.6.1.4.1.4874.2.2.10.1.1.2.1.5 |
juniFrDlcmiFullEnquiryIntervalNumber of status enquiry intervals that pass before issuance of a full
status enquiry message.
Pertains to DTE/NNI operation only. This parameter can be reconfigured
only when the Frame Relay interface is acting as a DTE or NNI.rw Integer32 .1.3.6.1.4.1.4874.2.2.10.1.1.2.1.6 |
juniFrDlcmiErrorThresholdThe minimum number of errors that must be observed within the number of
events specified by juniFrDlcmiMonitoredEvents, to declare the interface
down.
'error' is lack of receipt of a Status, in response to an issued Status
Enquiry, within the Polling Interval (T391).
Pertains to DTE/NNI operation only. This parameter can be reconfigured
only when the Frame Relay interface is acting as a DTE or NNI.rw Integer32 .1.3.6.1.4.1.4874.2.2.10.1.1.2.1.7 |
juniFrDlcmiMonitoredEventsThe number of status polling intervals over which the error threshold
is counted. For example, if within 'MonitoredEvents' number of events
the station receives 'ErrorThreshold' number of errors, the interface is
marked as down.
'status polling interval' is specified by juniFrDlcmiPollingInterval.
Pertains to DTE/NNI operation only. This parameter can be reconfigured
only when the Frame Relay interface is acting as a DTE or NNI.rw Integer32 .1.3.6.1.4.1.4874.2.2.10.1.1.2.1.8 |
juniFrDlcmiMaxSupportedVCsThe maximum number of Virtual Circuits allowed for this interface.
Usually dictated by the Frame Relay network.
In response to a SET, if a value less than zero or higher than the
agent's maximal capability is configured, the agent should respond
badValue.rw DLCI (FRAME-RELAY-DTE-MIB) .1.3.6.1.4.1.4874.2.2.10.1.1.2.1.9 |
juniFrDlcmiMulticastThis indicates whether the Frame Relay interface is using a multicast
service.rw Enumeration .1.3.6.1.4.1.4874.2.2.10.1.1.2.1.10 |
juniFrDlcmiStatusThis indicates the status of the Frame Relay interface as determined by
the performance of the DLCMI. If no DLCMI is running, the Frame Relay
interface will stay in the running state indefinitely.ro Enumeration .1.3.6.1.4.1.4874.2.2.10.1.1.2.1.11 |
juniFrDlcmiRowStatusControls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniFrDlcmiRowStatus
juniFrDlcmiState
juniFrDlcmiMaxSupportedVCs
juniFrDlcmiLowerIfIndex
juniFrDlcmiRole
juniFrDlcmiMultilinkFrBundleName (Only for multilink frame relay)
In addition, when creating an entry the following conditions must hold:
A value for juniFrDlcmiIndex must have been determined previously,
by reading juniFrNextIfIndex.
The interface identified by juniFrDlcmiLowerIfIndex must exist, and
must be an interface type that permits layering of Frame Relay above
it.
A corresponding entry in ifTable/ifXTable/juniIfTable is created/
destroyed as a result of creating/destroying an entry in this table. If
juniFrDlcmiRole is dte(0), a corresponding entry is created/deleted in
frDlcmiTable.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.4874.2.2.10.1.1.2.1.12 |
juniFrDlcmiLowerIfIndexThe ifIndex of an interface over which this Frame Relay interface is to
be layered. A value of zero indicates no layering. An implementation
may choose to require that a nonzero value be configured at entry
creation. In case of multilink frame relay support, it will be
multilink frame relay interface's ifIndex.rw InterfaceIndexOrZero (IF-MIB) .1.3.6.1.4.1.4874.2.2.10.1.1.2.1.13 |
juniFrDlcmiRoleSpecifies the role this interface assumes with respect to the remote
end.
When acting as a DTE, the following objects are not relevant:
juniFrDlcmiDcePollingInterval
juniFrDlcmiDceErrorThreshold
juniFrDlcmiDceMonitoredEvents
When acting as a DCE, the following objects are not relevant:
juniFrDlcmiPollingInterval
juniFrDlcmiFullEnquiryInterval
juniFrDlcmiErrorThreshold
juniFrDlcmiMonitoredEventsrw Enumeration .1.3.6.1.4.1.4874.2.2.10.1.1.2.1.14 |
juniFrDlcmiDcePollingIntervalThe number of seconds within which a DCE expects to receive a Status
Enquiry from the DTE.
This value corresponds to the T392 timer.
Pertains to DCE/NNI operation only. This parameter can be reconfigured
only when the Frame Relay interface is acting as a DCE or NNI.rw Integer32 .1.3.6.1.4.1.4874.2.2.10.1.1.2.1.15 |
juniFrDlcmiDceErrorThresholdThe minimum number of errors that must be observed within the number of
events specified by juniFrDlcmiDceMonitoredEvents, to declare the
interface down.
'error' is lack of receipt of a Status Enquiry within the interval
specified by juniFrDlcmiDcePollingInterval (T392).
Pertains to DCE/NNI operation only. This parameter can be reconfigured
only when the Frame Relay interface is acting as a DCE or NNI.rw Integer32 .1.3.6.1.4.1.4874.2.2.10.1.1.2.1.16 |
juniFrDlcmiDceMonitoredEventsThe number of DCE polling intervals over which accumulated errors are
counted against the threshold specified in juniFrDlcmiDceErrorThreshold.
If, within this number of events, the number of errors equals or exceeds
the threshold, the interface is declared down.
The 'DCE polling interval' is specified by
juniFrDlcmiDcePollingInterval.
Pertains to DCE/NNI operation only. This parameter can be reconfigured
only when the Frame Relay interface is acting as a DCE or NNI.rw Integer32 .1.3.6.1.4.1.4874.2.2.10.1.1.2.1.17 |
juniFrDlcmiMultilinkFrBundleNameThis represents multilink frame relay bundle name. This object must be
configured to associate the bundle name to the frame relay major
interface to support the multilink frame relay encapsulation. For
non-multilink frame relay, bundle name configuration is not valid and
will be ignored.rw JuniFrMlFrBundleName .1.3.6.1.4.1.4874.2.2.10.1.1.2.1.18 |
juniFrDlcmiStatsTableThe statistics for the Data Link Connection Management Interface for
the frame relay service on this interface. SEQUENCE OF JuniFrDlcmiStatsEntry .1.3.6.1.4.1.4874.2.2.10.1.1.3 |
juniFrDlcmiStatsEntryThe statistics for a particular Data Link Connection Management
Interface.
Statistics are not relevant while the juniFrDlcmiState has the value
'noLmiConfigured'.
The DTE statistics are relevant when the corresponding juniFrDlcmiRole
is DTE.
The DTE statistics are relevant when the corresponding juniFrDlcmiRole
is DCE. JuniFrDlcmiStatsEntry .1.3.6.1.4.1.4874.2.2.10.1.1.3.1 |
juniFrDlcmiStatsDteEnquiriesNumber of Status Enquiries sent (as DTE).ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.3.1.1 |
juniFrDlcmiStatsDteFullEnquiriesNumber of Full Enquiries sent (as DTE).ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.3.1.2 |
juniFrDlcmiStatsDteEnquiryResponsesNumber of Status Enquiry responses received (as DTE).ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.3.1.3 |
juniFrDlcmiStatsDteFullEnquiryResponsesNumber of Full Enquiry responses received (as DTE).ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.3.1.4 |
juniFrDlcmiStatsDteAsyncUpdatesNumber of Asynchronous Updates received (as DTE).ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.3.1.5 |
juniFrDlcmiStatsDteUnknownRxMessagesNumber of unknown messages received (as DTE).ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.3.1.6 |
juniFrDlcmiStatsDteLossOfSequencesNumber of times a discontinuity in sequence numbering of received
messages was detected (as DTE).ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.3.1.7 |
juniFrDlcmiStatsDteNoResponseTimeoutsNumber of timer expirations awaiting a Status message (as DTE).ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.3.1.8 |
juniFrDlcmiStatsDceEnquiriesNumber of Status Enquiries received (as DCE.)ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.3.1.9 |
juniFrDlcmiStatsDceFullEnquiriesNumber of Full Enquiries received (as DCE).ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.3.1.10 |
juniFrDlcmiStatsDceEnquiryResponsesNumber of Status Enquiry responses sent (as DCE).ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.3.1.11 |
juniFrDlcmiStatsDceFullEnquiryResponsesNumber of Full Enquiry responses sent (as DCE).ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.3.1.12 |
juniFrDlcmiStatsDceAsyncUpdatesNumber of Asynchronous Updates sent (as DCE).ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.3.1.13 |
juniFrDlcmiStatsDceUnknownRxMessagesNumber of unknown messages received (as DCE).ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.3.1.14 |
juniFrDlcmiStatsDceLossOfSequencesNumber of times a discontinuity in sequence numbering of received
messages was detected (as DCE).ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.3.1.15 |
juniFrDlcmiStatsDceNoResponseTimeoutsNumber of timer expirations awaiting a Status Enquiry (as DCE).ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.3.1.16 |
juniFrDlcmiStatsDiscontinuityTimeValue of sysUpTime at the most recent event that caused a discontinuity
in the monotonic operation of any of the counters in this entry. Such
disruption might be caused by:
Hardware insertion/removal.
Reconfiguration of juniFrDlcmiState.
Reconfiguration of juniFrDlcmiRole.
Conclusions can be drawn from successive polls of an entry's counters
only if the value of this object, simultaneously retrieved in those
polls, remains unchanged.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.4874.2.2.10.1.1.3.1.17 |
juniFrCircuitTableA table containing information about specific Data Link Connections
(DLC) or virtual circuits.
This table mirrors the structure of FRAME-RELAY-DTE-MIB.frCircuitTable,
for the purpose of enumerating circuits on both DTE and DCE Frame Relay
interfaces. SEQUENCE OF JuniFrCircuitEntry .1.3.6.1.4.1.4874.2.2.10.1.1.4 |
juniFrCircuitEntryThe information regarding a single Data Link Connection.
Discontinuities in the counters contained in this table are indicated by
the value in juniFrCircuitCreationTime. JuniFrCircuitEntry .1.3.6.1.4.1.4874.2.2.10.1.1.4.1 |
juniFrCircuitIfIndexThe ifIndex Value of the ifEntry this virtual circuit is layered onto. InterfaceIndex (IF-MIB) .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.1 |
juniFrCircuitDlciThe Data Link Connection Identifier for this virtual circuit. DLCI (FRAME-RELAY-DTE-MIB) .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.2 |
juniFrCircuitStateIndicates whether the particular virtual circuit is operational. In
the absence of a Data Link Connection Management Interface, virtual
circuit entries (rows) may be created by setting virtual circuit state
to 'active', or deleted by changing Circuit state to 'invalid'.
Whether or not the row actually disappears is left to the
implementation, so this object may actually read as 'invalid' for some
arbitrary length of time. It is also legal to set the state of a
virtual circuit to 'inactive' to temporarily disable a given circuit.
The use of 'invalid' is deprecated in this SNMP Version 2 MIB, in favor
of juniFrCircuitRowStatus.rw Enumeration .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.3 |
juniFrCircuitReceivedFECNsNumber of frames received from the network indicating forward
congestion since the virtual circuit was created. This occurs when the
remote DTE sets the FECN flag, or when a switch in the network enqueues
the frame to a trunk whose transmission queue is congested.ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.4 |
juniFrCircuitReceivedBECNsNumber of frames received from the network indicating backward
congestion since the virtual circuit was created. This occurs when the
remote DTE sets the BECN flag, or when a switch in the network receives
the frame from a trunk whose transmission queue is congested.ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.5 |
juniFrCircuitSentFramesThe number of frames sent from this virtual circuit since it was
created.ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.6 |
juniFrCircuitSentOctetsThe number of octets sent from this virtual circuit since it was
created. Octets counted are the full frame relay header and the
payload, but do not include the flag characters or CRC.ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.7 |
juniFrCircuitReceivedFramesNumber of frames received over this virtual circuit since it was
created.ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.8 |
juniFrCircuitReceivedOctetsNumber of octets received over this virtual circuit since it was
created. Octets counted include the full frame relay header, but do not
include the flag characters or the CRC.ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.9 |
juniFrCircuitCreationTimeThe value of sysUpTime when the virtual circuit was created, whether by
the Data Link Connection Management Interface or by a SetRequest.ro TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.10 |
juniFrCircuitLastTimeChangeThe value of sysUpTime when last there was a change in the virtual
circuit statero TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.11 |
juniFrCircuitCommittedBurstThis variable indicates the maximum amount of data, in bits, that the
network agrees to transfer under normal conditions, during the
measurement interval. A value of zero (the default) indicates no
commitment.rw Integer32 .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.12 |
juniFrCircuitExcessBurstThis variable indicates the maximum amount of uncommitted data bits
that the network will attempt to deliver over the measurement interval.
By default, if not configured when creating the entry, the Excess
Information Burst Size is set to the value of ifSpeed.rw Integer32 .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.13 |
juniFrCircuitThroughputThroughput is the average number of 'Frame Relay Information Field'
bits transferred per second across a user network interface in one
direction, measured over the measurement interval.
If the configured committed burst rate and throughput are both non-zero,
the measurement interval, T, is
T = juniFrCircuitCommittedBurst / juniFrCircuitThroughput.
If the configured committed burst rate and throughput are both zero, the
measurement interval, T, is
T = juniFrCircuitExcessBurst / ifSpeed
A value of zero (the default) for throughput indicates no commitment.rw Integer32 .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.14 |
juniFrCircuitMulticastThis indicates whether this VC is used as a unicast VC (i.e. not
multicast) or the type of multicast service subscribed to.rw Enumeration .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.15 |
juniFrCircuitTypeIndication of whether the VC was manually created (static), or
dynamically created (dynamic) via the data link control management
interface.ro Enumeration .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.16 |
juniFrCircuitDiscardsThe number of inbound frames dropped because of format errors, or
because the VC is inactive.ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.17 |
juniFrCircuitReceivedDEsNumber of frames received from the network indicating that they were
eligible for discard since the virtual circuit was created. This occurs
when the remote DTE sets the DE flag, or when in remote DTE's switch
detects that the frame was received as Excess Burst data.ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.18 |
juniFrCircuitSentDEsNumber of frames sent to the network indicating that they were eligible
for discard since the virtual circuit was created. This occurs when the
local DTE sets the DE flag, indicating that during Network congestion
situations those frames should be discarded in preference of other
frames sent without the DE bit set.ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.19 |
juniFrCircuitLogicalIfIndexNormally the same value as frDlcmiIfIndex, but different when an
implementation associates a virtual ifEntry with a DLC or set of DLCs in
order to associate higher layer objects such as the ipAddrEntry with a
subset of the virtual circuits on a Frame Relay interface. The type of
such ifEntries is defined by the higher layer object; for example, if
PPP/Frame Relay is implemented, the ifType of this ifEntry would be PPP.
If it is not so defined, as would be the case with an ipAddrEntry, it
should be of type Other.rw InterfaceIndex (IF-MIB) .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.20 |
juniFrCircuitRowStatusThis object is used to create a new row or modify or destroy an
existing row in the manner described in the definition of the RowStatus
textual convention. Writable objects in the table may be written in any
RowStatus state.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.21 |
juniFrCircuitSentFECNsNumber of frames sent to the network indicating forward congestion
since the virtual circuit was created. This occurs when the remote DTE
sets the FECN flag, or when a switch in the network enqueues the frame
to a trunk whose transmission queue is congested.ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.22 |
juniFrCircuitSentBECNsNumber of frames sent to the network indicating backward congestion
since the virtual circuit was created. This occurs when the remote DTE
sets the BECN flag, or when a switch in the network receives the frame
from a trunk whose transmission queue is congested.ro Counter32 .1.3.6.1.4.1.4874.2.2.10.1.1.4.1.23 |
juniFrSubIfLayer OBJECT IDENTIFIER .1.3.6.1.4.1.4874.2.2.10.1.2 |
juniFrSubIfNextIfIndexCoordinate ifIndex value allocation for entries in juniFrSubIfTable.
A GET of this object returns the next available ifIndex value to be used
to create an entry in the associated interface table; or zero, if no
valid ifIndex value is available. This object also returns a value of
zero when it is the lexicographic successor of a varbind presented in an
SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
that ifIndex allocation is unintended.
Successive GETs will typically return different values, thus avoiding
collisions among cooperating management clients seeking to create table
entries simultaneously.ro JuniNextIfIndex (Juniper-TC) .1.3.6.1.4.1.4874.2.2.10.1.2.1 |
juniFrSubIfTableThis table contains entries for Frame Relay Subinterfaces present in
the system. SEQUENCE OF JuniFrSubIfEntry .1.3.6.1.4.1.4874.2.2.10.1.2.2 |
juniFrSubIfEntryEach entry describes the characteristics of a Frame Relay Subinterface.
Creating/deleting entries in this table causes corresponding entries for
be created /deleted in ifTable/ifXTable/juniIfTable. JuniFrSubIfEntry .1.3.6.1.4.1.4874.2.2.10.1.2.2.1 |
juniFrSubIfIndexThe ifIndex of the Frame Relay Subinterface. When creating entries in
this table, suitable values for this object are determined by reading
juniFrSubNextIfIndex. InterfaceIndex (IF-MIB) .1.3.6.1.4.1.4874.2.2.10.1.2.2.1.1 |
juniFrSubIfRowStatusControls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniFrSubIfRowStatus
juniFrSubIfLowerIfIndex
In addition, when creating an entry the following conditions must hold:
A value for juniFrSubIfIndex must have been determined previously,
by reading juniFrSubIfNextIfIndex.
The interface identified by juniFrSubIfLowerIfIndex must exist, and
must be a Frame Relay interface.
A positive value configured for juniFrSubIfId must not already be
assigned to another subinterface layered onto the same underlying
Frame Relay interface.
A corresponding entry in ifTable/ifXTable/juniIfTable is created/
destroyed as a result of creating/destroying an entry in this table.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.4874.2.2.10.1.2.2.1.2 |
juniFrSubIfLowerIfIndexThe ifIndex of a Frame Relay interface over which this Frame Relay
Subinterface is to be layered. A value of zero indicates no layering.
An implementation may choose to require that a nonzero value be
configured at entry creation.rw InterfaceIndexOrZero (IF-MIB) .1.3.6.1.4.1.4874.2.2.10.1.2.2.1.3 |
juniFrSubIfIdAn integer identifier for the Frame Relay subinterface, used in
conjunction with the command-line interface. It is provided here for
cross-reference purposes only.
The value must be unique among subinterfaces configured on the same
underlying Frame Relay interface.
If this object is not configured, or is configured with a value of -1, a
nonzero value will be allocated internally and can be retrieved from
this object after table entry creation has succeeded.
A value of zero for this object is reserved for future use.rw Integer32 (-1..2147483647) .1.3.6.1.4.1.4874.2.2.10.1.2.2.1.4 |
juniFrSubIfCktTableThis table contains entries for Frame Relay circuits configured on
Frame Relay Subinterfaces present in the system.
An implementation may constrain the number of circuits permitted to be
configured per Frame Relay Subinterface; in particular, an
implementation may restrict each Frame Relay Subinterface to have a
single circuit.
Attributes in this entry can only be configured at entry creation, and
remain fixed for the lifetime of the entry. SEQUENCE OF JuniFrSubIfCktEntry .1.3.6.1.4.1.4874.2.2.10.1.2.3 |
juniFrSubIfCktEntryEach entry describes the characteristics of a Frame Relay Subinterface
circuit. JuniFrSubIfCktEntry .1.3.6.1.4.1.4874.2.2.10.1.2.3.1 |
juniFrSubIfCktDlciThe DLCI of the Frame Relay circuit used by this subinterface. DLCI (FRAME-RELAY-DTE-MIB) .1.3.6.1.4.1.4874.2.2.10.1.2.3.1.1 |
juniFrSubIfCktRowStatusControls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniFrSubIfCktRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.4874.2.2.10.1.2.3.1.2 |
juniFrMlFr OBJECT IDENTIFIER .1.3.6.1.4.1.4874.2.2.10.1.3 |
juniFrMlFrBundleTableThis table contains entries for MLFR bundles present in the system. SEQUENCE OF JuniFrMlFrBundleEntry .1.3.6.1.4.1.4874.2.2.10.1.3.1 |
juniFrMlFrBundleEntryEach entry describes the characteristics of a Multilink bundle. JuniFrMlFrBundleEntry .1.3.6.1.4.1.4874.2.2.10.1.3.1.1 |
juniFrMlFrBundleNameThe administrative name of the multilink bundle associated with this
Frame Relay major interface. JuniFrMlFrBundleName .1.3.6.1.4.1.4874.2.2.10.1.3.1.1.1 |
juniFrMlFrBundleRowStatusThe rowStatus for this entry. The following sets are supported:
createAndGo(4),
destroy(6)
The following values can be read from this object:
active(1)rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.4874.2.2.10.1.3.1.1.2 |
juniFrMlFrNextLinkIfIndexCoordinate ifIndex value allocation for entries in
juniFrMlFrLinkConfigTable.
A GET of this object returns the next available ifIndex value to be used
to create an entry in the associated interface table; or zero, if no
valid ifIndex value is available. This object also returns a value of
zero when it is the lexicographic successor of a varbind presented in an
SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
that ifIndex allocation is unintended.
Successive GETs will typically return different values, thus avoiding
collisions among cooperating management clients seeking to create table
entries simultaneously.ro JuniNextIfIndex (Juniper-TC) .1.3.6.1.4.1.4874.2.2.10.1.3.2 |
juniFrMlFrLinkConfigTableThis table contains entries for FR link interfaces present in the
system to be added to the multilink bundles. SEQUENCE OF JuniFrMlFrLinkConfigEntry .1.3.6.1.4.1.4874.2.2.10.1.3.3 |
juniFrMlFrLinkConfigEntryEach entry describes the characteristics of FR link interface.
Creating/deleting entries in this table causes corresponding entries for
be created/deleted in ifTable/ifXTable/juniIfTable. JuniFrMlFrLinkConfigEntry .1.3.6.1.4.1.4874.2.2.10.1.3.3.1 |
juniFrMlFrLinkConfigIfIndexThe ifIndex of the FR link interface. When creating entries in this
table, suitable values for this object are determined by reading
juniFrMlFrNextLinkIfIndex. InterfaceIndex (IF-MIB) .1.3.6.1.4.1.4874.2.2.10.1.3.3.1.1 |
juniFrMlFrLinkConfigLowerIfIndexThe ifIndex of an interface over which this FR link interface is to be
layered. A value of zero indicates no layering. An implementation may
choose to require that a non-zero value be configured at entry
creation.rw InterfaceIndexOrZero (IF-MIB) .1.3.6.1.4.1.4874.2.2.10.1.3.3.1.2 |
juniFrMlFrLinkConfigRowStatusControls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniFrMlFrLinkConfigRowStatus
juniFrMlFrLinkConfigLowerIfIndex
In addition, when creating an entry the following conditions must hold:
A value for juniFrMlFrLinkConfigIfIndex must have been determined
previously, by reading juniFrMlFrNextIfIndex.
The interface identified by juniFrMlFrLinkConfigLowerIfIndex must
exist.
A corresponding entry in ifTable/ifXTable/juniIfTable is created/
destroyed as a result of creating/destroying an entry in this table.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.4874.2.2.10.1.3.3.1.3 |
juniFrMlFrMajorConfigTableThis table contains entries for FR major interfaces present in the
system which are associated with multilink bundles. SEQUENCE OF JuniFrMlFrMajorConfigEntry .1.3.6.1.4.1.4874.2.2.10.1.3.4 |
juniFrMlFrMajorConfigEntryEach entry describes the characteristics of FR major interface which
have association with the MLFR bundles. Creating/deleting entries in
this table causes corresponding entries for be created/deleted in
ifTable/ifXTable/juniIfTable. JuniFrMlFrMajorConfigEntry .1.3.6.1.4.1.4874.2.2.10.1.3.4.1 |
juniFrMlFrMajorConfigIfIndexThe ifIndex of the FR Major interface. When creating entries in this
table, suitable values for this object are determined by reading already
created FR Major interface values.
Each multilink bundle will be associated with one FR major interface.
This association will be done at the creation of FR major interface
(juniFrDlcmiTable) specifying its lower interfce binding as FR link
ifIndex(juniFrMlFrLinkConfigTable) and the multilink bundle name. InterfaceIndex (IF-MIB) .1.3.6.1.4.1.4874.2.2.10.1.3.4.1.1 |
juniFrMlFrMajorConfigLowerIfIndexThe ifIndex of a FR link interface over which this FR Major interface
is to be layered. On sets, the value of this object must equal on of
the previously created FR link interfaces created in the
juniFrMlFrLinkConfigTable. On gets, the value of this object is the
lexicographically least FR link interface in a potential bundle of FR
link interfaces.rw InterfaceIndex (IF-MIB) .1.3.6.1.4.1.4874.2.2.10.1.3.4.1.2 |
juniFrMlFrMajorBundleNameThe MLFR bundle name administratively assigned.rw JuniFrMlFrBundleName .1.3.6.1.4.1.4874.2.2.10.1.3.4.1.3 |
juniFrMlFrMajorRowStatusControls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniFrMlFrMajorConfigLowerIfIndex
juniFrMlFrMajorBundleName
juniFrMlFrMajorConfigRowStatus
In addition, when creating an entry the following conditions must hold:
The interface identified by juniFrMlFrMajorConfigIndex must exist by
a creation request to the juniFrDlcmiTable.
The interface identified by juniFrMlFrMajorConfigLowerIfIndex must
exist by a creation request to the juniFrMlFrLinkConfigTable.
The bundleName specified in juniFrMlFrMajorBundleName must have
been created first in the juniFrMlFrBundleTable.
A corresponding entry in ifTable/ifXTable/juniIfTable is created/
destroyed as a result of creating/destroying an entry in this table.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.4874.2.2.10.1.3.4.1.4 |
juniFrMlFrLinkBindTableThis table contains entries for FR Link interfaces to FR major
interfaces bindings associated with multilink bundles. SEQUENCE OF JuniFrMlFrLinkBindEntry .1.3.6.1.4.1.4874.2.2.10.1.3.5 |
juniFrMlFrLinkBindEntryEach entry describes the FR link interface to FR major interface
bindingsi associated with multilink bundles. JuniFrMlFrLinkBindEntry .1.3.6.1.4.1.4874.2.2.10.1.3.5.1 |
juniFrMlFrBindMajorIfIndexThe ifIndex of the FR major interface associated with multilink. InterfaceIndex (IF-MIB) .1.3.6.1.4.1.4874.2.2.10.1.3.5.1.1 |
juniFrMlFrBindLinkIfIndexThe ifIndex of a FR link interface bound by the FR major interface
defined by juniFrMlFrBindMajorIfIndex. InterfaceIndex (IF-MIB) .1.3.6.1.4.1.4874.2.2.10.1.3.5.1.2 |
juniFrMlFrBindRowStatusControls creation/deletion of entries in this table according to the
RowStatus textual convention, constrained to support the following
values only:
createAndGo
destroy
To create an entry in this table, the following entry objects MUST be
explicitly configured:
juniFrMlFrBindRowStatus
In addition, when creating an entry the following conditions must hold:
The interfaces identified by juniFrMlFrBindNetworkIfIndex and
juniFrMlFrBindLinkIfIndex must be created in the
juniFrMlFrMajorConfigTable and juniFrMlFrLinkConfigTable
respectively.
A MLFR bundle must be associated with the juniFrMlFrMajorIfIndex and
exist in the juniFrMibFrBundleTable.
A corresponding entry in ifStackTable is created/destroyed as a result
of creating/destroying an entry in this table.
Note: This table is read-only table for now. To add links to bundle
make use of juniFrMlFrMajorConfigTable.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.4874.2.2.10.1.3.5.1.3 |
juniFrConformance OBJECT IDENTIFIER .1.3.6.1.4.1.4874.2.2.10.4 |
juniFrCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.4874.2.2.10.4.1 |
juniFrGroups OBJECT IDENTIFIER .1.3.6.1.4.1.4874.2.2.10.4.2 |