Home/Catalog/Juniper-DS1-MIB

Juniper-DS1-MIB

AI MIB Summary

The Juniper-DS1-MIB module extends RFC 1406 to monitor DS1 and E1 physical layer interfaces on Juniper devices, tracking critical metrics such as line status, CRC errors, framing errors, and signal loss alarms.

The DS1/E1 MIB for the Juniper enterprise. This MIB contains managed objects to supplement those found in RFC1406 DS1/E1 MIB.
Main OID:
juniDs1MIB.1.3.6.1.4.1.4874.2.2.5
51
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

51 total
Object Name
juniDs1MIBThe DS1/E1 MIB for the Juniper enterprise. This MIB contains managed objects to supplement those found in RFC1406 DS1/E1 MIB.
MODULE-IDENTITY
.1.3.6.1.4.1.4874.2.2.5
juniDs1Objects
OBJECT IDENTIFIER
.1.3.6.1.4.1.4874.2.2.5.1
juniDsx1ConfigTableThis table contains entries for DS1/E1 interfaces present in the system.
SEQUENCE OF JuniDsx1ConfigEntry
.1.3.6.1.4.1.4874.2.2.5.1.1
juniDsx1ConfigEntryEach entry describes the characteristics of an DS1/E1 interface.
JuniDsx1ConfigEntry
.1.3.6.1.4.1.4874.2.2.5.1.1.1
juniDsx1TimeSlotMapA bitmap representing the timeslots on the DS1/E1 interface that have been allocated for service. For channelized DS1/E1, set bits reflect the union of timeslot allocations across all fractional arrangements operating over this DS1/E1 interface. For unchannelized DS1/E1, all relevant timeslot bits will be set.ro
JuniTimeSlotMap (Juniper-TC)
.1.3.6.1.4.1.4874.2.2.5.1.1.1.1
juniDsx1Ds1ChannelNumberThis variable represents the channel number of the DS1/E1 on its parent DS3/E3. A value of 0 indicates this DS1/E1 does not have a parent DS3/E3.rw
Integer32
.1.3.6.1.4.1.4874.2.2.5.1.1.1.2
juniDsx1CapabilitiesA value which indicates the set of capabilities of the DS1/E1 interface. The value is a sum. This sum initially takes the value zero. Then, for each capability, C, in the range 1 through 3, that this interface supports, 2 raised to (C - 1) is added to the sum. For example, an interface which is only E1 capable would have a value of 2 (2^(2-1)). In contrast, an interface which is both T1 and J1 capable would have a value of 5 (2^(1-1) + 2^(3-1)). The values for DS1/E1 interface capabilities are as follows: capability function 1 T1 2 E1 3 J1ro
Integer32
.1.3.6.1.4.1.4874.2.2.5.1.1.1.3
juniDsx1ModeThis variable represents the DS1/E1 interface mode. The value of the juniDsx1Capabilities object for the DS1/E1 interface indicates the valid set of values for this object.rw
Enumeration
.1.3.6.1.4.1.4874.2.2.5.1.1.1.4
juniDsx1LineBuildOutCapabilitiesA value which indicates the set of line build out capabilities of the DS1/E1 interface. The value is a sum. This sum initially takes the value zero. Then, for each line build out capability, C, in the range 1 or 2, that this interface supports, 2 raised to (C - 1) is added to the sum. For example, an interface which is only short haul capable would have a value of 2 (2^(2-1)). In contrast, an interface which is both short haul and long haul capable would have a value of 3 (2^(1-1) + 2^(2-1)). The values for DS1/E1 interface line build out capabilities are as follows: line build out capability function 1 short haul 2 long haulro
Integer32
.1.3.6.1.4.1.4874.2.2.5.1.1.1.5
juniDsx1LineBuildOutTypeThis variable represents the configured line build out type of the DS1/E1 interface. The value of the juniDsx1LineBuildOutCapabilities object for the DS1/E1 interface indicates the valid set of values for this object.rw
Enumeration
.1.3.6.1.4.1.4874.2.2.5.1.1.1.6
juniDsx1LineAttenuationThis variable represents the configured line attenuation of the DS1/E1 interface. Note that the value of this object only takes effect when the value of the juniDsx1LineBuildOutType for the DS1/E1 interface is set to longHaul(2).rw
Enumeration
.1.3.6.1.4.1.4874.2.2.5.1.1.1.7
juniDsx1LineLengthThis variable represents the length of the DS1/E1 line in meters. Note that the value of this object only takes effect when the value of the juniDsx1LineBuildOutType for the DS1/E1 interface is set to shortHaul(1).rw
Integer32
.1.3.6.1.4.1.4874.2.2.5.1.1.1.8
juniDsx1LowerIfIndexThe ifIndex of the interface over which this Dsx1 interface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation.rw
InterfaceIndexOrZero (IF-MIB)
.1.3.6.1.4.1.4874.2.2.5.1.1.1.9
juniDsx1RowStatusControls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniDsx1RowStatus juniDsx1LowerIfIndex In addition, when creating an entry the following conditions must hold: A value for ifIndex must have been determined previously, by reading juniDsx1NextIfIndex. The interface identified by juniDsx1hLowerIfIndex must exist. A corresponding entry in ifTable/ifXTable/juniIfTable is created/ destroyed as a result of creating/destroying an entry in this table.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.4874.2.2.5.1.1.1.10
juniDsx1SendCodeThis variable indicates what type of code is being sent across the DS1 interface by the device.rw
Enumeration
.1.3.6.1.4.1.4874.2.2.5.1.1.1.11
juniDsx1YellowAlarmThis bitmap indicates the yellow alarm settings, and is the sum of the capabilities.rw
Enumeration
.1.3.6.1.4.1.4874.2.2.5.1.1.1.12
juniDsx1RemoteLoopbackThis variable indicates the remote loopback setting.rw
Enumeration
.1.3.6.1.4.1.4874.2.2.5.1.1.1.13
juniDsx1FdlCarrierSpecifies the interface is used in carrier environment.rw
Enumeration
.1.3.6.1.4.1.4874.2.2.5.1.1.1.14
juniDsx1FdlEicThis is the equipment identification code.rw
DisplayString
.1.3.6.1.4.1.4874.2.2.5.1.1.1.15
juniDsx1FdlLicThis is the location identification code.rw
DisplayString
.1.3.6.1.4.1.4874.2.2.5.1.1.1.16
juniDsx1FdlFicThis is the frame identification code.rw
DisplayString
.1.3.6.1.4.1.4874.2.2.5.1.1.1.17
juniDsx1FdlUnitThis is the unit identification code.rw
DisplayString
.1.3.6.1.4.1.4874.2.2.5.1.1.1.18
juniDsx1FdlPfiThis is the facility identification code.rw
DisplayString
.1.3.6.1.4.1.4874.2.2.5.1.1.1.19
juniDsx1FdlPortThis is the equipment port number.rw
DisplayString
.1.3.6.1.4.1.4874.2.2.5.1.1.1.20
juniDsx1FdlGeneratorThis is the generator number.rw
DisplayString
.1.3.6.1.4.1.4874.2.2.5.1.1.1.21
juniDsx1FdlTransmitSpecifies transmission enabling. path - Bit 0 for path transmit. When this bit is set indicates path transmit is enabled; otherwise path transmit disabled. idlesignal - Bit 1 for idlesignal transmit. When this bit is set idlesingal transmit is enabled; otherwise idlesignal transmit disabled. testsignal - Bit 2 for testsignal transmit. When this bit is set testsignal transmit is enabled; otherwise testsignal transmit disabled. The value of this object defaults to zero, indicating that none of FDL transmit methods are enabled.rw
Bits
.1.3.6.1.4.1.4874.2.2.5.1.1.1.22
juniDs1NextIfIndexCoordinate ifIndex value allocation for entries in juniDsx1ConfigTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously.ro
JuniNextIfIndex (Juniper-TC)
.1.3.6.1.4.1.4874.2.2.5.1.2
juniDsx1FarEndConfigTableThe DS1 Far End Configuration table.
SEQUENCE OF JuniDsx1FarEndConfigEntry
.1.3.6.1.4.1.4874.2.2.5.1.3
juniDsx1FarEndConfigEntryAn entry in the DS1 Far End Configuration table.
JuniDsx1FarEndConfigEntry
.1.3.6.1.4.1.4874.2.2.5.1.3.1
juniDsx1FarEndLineIndexThe index value which uniquely identifies the DS1 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value a dsx1LineIndex object instance.
INTEGER (1..'7fffffff'h)
.1.3.6.1.4.1.4874.2.2.5.1.3.1.1
juniDsx1FarEndEquipCodeThis is the Far End Equipment Identification code that describes the specific piece of equipment. It is sent within the Path Identification Message.ro
DisplayString
.1.3.6.1.4.1.4874.2.2.5.1.3.1.2
juniDsx1FarEndLocationIDCodeThis is the Far End Location Identification code that describes the specific location of the equipment. It is sent within the Path Identification Message.ro
DisplayString
.1.3.6.1.4.1.4874.2.2.5.1.3.1.3
juniDsx1FarEndFrameIDCodeThis is the Far End Frame Identification code that identifies where the equipment is located within a building at a given location. It is sent within the Path Identification Message.ro
DisplayString
.1.3.6.1.4.1.4874.2.2.5.1.3.1.4
juniDsx1FarEndUnitCodeThis is the Far End code that identifies the equipment location within a bay. It is sent within the Path Identification Message.ro
DisplayString
.1.3.6.1.4.1.4874.2.2.5.1.3.1.5
juniDsx1FarEndFacilityIDCodeThis code identifies a specific Far End DS1 path. It is sent within the Path Identification Message.ro
DisplayString
.1.3.6.1.4.1.4874.2.2.5.1.3.1.6
juniDsx1FarEndPortNumberThis code identifies the port number of the Far End DS1. It is sent within the Idle Signal Message.ro
DisplayString
.1.3.6.1.4.1.4874.2.2.5.1.3.1.7
juniDsx1FarEndGeneratorNumberThis code identifies the Far End DS1 Generator Number. It is sent within the Test Signal Message.ro
DisplayString
.1.3.6.1.4.1.4874.2.2.5.1.3.1.8
juniDsx1FarEndCarrierSpecifies the interface is used in carrier environment. It is sent with all FDL messages.ro
Enumeration
.1.3.6.1.4.1.4874.2.2.5.1.3.1.9
juniDs1Conformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.4874.2.2.5.4
juniDs1Compliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.4874.2.2.5.4.1
juniDs1ComplianceObsolete compliance statement for entities which implement the Juniper DS1/E1 MIB. This statement became obsolete when new objects were added.obsolete
Unknown
.1.3.6.1.4.1.4874.2.2.5.4.1.1
juniDs1Compliance2Obsolete compliance statement for entities which implement the Juniper DS1/E1 MIB. This statement became obsolete when dynamic DS1 interface support was added.obsolete
Unknown
.1.3.6.1.4.1.4874.2.2.5.4.1.2
juniDs1Compliance3Obsolete compliance statement for entities which implement the Juniper DS1/E1 MIB. This statement became obsolete when FDL support was added.obsolete
Unknown
.1.3.6.1.4.1.4874.2.2.5.4.1.3
juniDs1Compliance4Obsolete compliance statement for entities which implement the Juniper DS1/E1 MIB. This statement became obsolete when support for remote FDL strings and FDL transmit mode was added.obsolete
Unknown
.1.3.6.1.4.1.4874.2.2.5.4.1.4
juniDs1Compliance5The compliance statement for entities which implement the Juniper DS1/E1 MIB.
Unknown
.1.3.6.1.4.1.4874.2.2.5.4.1.5
juniDs1Groups
OBJECT IDENTIFIER
.1.3.6.1.4.1.4874.2.2.5.4.2
juniDs1GroupObsolete collection of objects providing management of DS1/E1 interfaces in a Juniper product. This group became obsolete when new objects where added to the MIB.obsolete
Unknown
.1.3.6.1.4.1.4874.2.2.5.4.2.1
juniDs1Group2Obsolete collection of objects providing management of DS1/E1 interfaces in a Juniper product. This group became obsolete when dynamic DS1 interface support was added.obsolete
Unknown
.1.3.6.1.4.1.4874.2.2.5.4.2.2
juniDs1Group3Obsolete collection of objects providing management of DS1/E1 interfaces in a Juniper product. This group became obsolete when FDL support was added.obsolete
Unknown
.1.3.6.1.4.1.4874.2.2.5.4.2.3
juniDs1Group4Obsolete collection of objects providing management of DS1/E1 interfaces in a Juniper product. This group became obsolete when support for remote FDL strings and FDL transmit mode was added.obsolete
Unknown
.1.3.6.1.4.1.4874.2.2.5.4.2.4
juniDs1Group5A collection of objects providing management of DS1/E1 interfaces in a Juniper product.
Unknown
.1.3.6.1.4.1.4874.2.2.5.4.2.5