Juniper-ATM-1483-Profile-MIB
The Juniper-ATM-1483-Profile-MIB enables monitoring and configuration of ATM PVC and SVC parameters, specifically encapsulation types and traffic profiles, on Juniper Networks devices supporting RFC 1483 bridging over ATM interfaces.
Imported Objects
Objects
51 total| Object Name |
|---|
juniAtm1483ProfileMIB MODULE-IDENTITY .1.3.6.1.4.1.4874.2.2.58 |
juniAtm1483ProfileObjects OBJECT IDENTIFIER .1.3.6.1.4.1.4874.2.2.58.1 |
juniAtm1483Profile OBJECT IDENTIFIER .1.3.6.1.4.1.4874.2.2.58.1.1 |
juniAtm1483ProfileTable SEQUENCE OF JuniAtm1483ProfileEntry .1.3.6.1.4.1.4874.2.2.58.1.1.1 |
juniAtm1483ProfileEntry JuniAtm1483ProfileEntry .1.3.6.1.4.1.4874.2.2.58.1.1.1.1 |
juniAtm1483ProfileId Unsigned32 .1.3.6.1.4.1.4874.2.2.58.1.1.1.1.1 |
juniAtm1483ProfileSetMaprw JuniSetMap (Juniper-TC) .1.3.6.1.4.1.4874.2.2.58.1.1.1.1.2 |
juniAtm1483ProfileVccTyperw Enumeration .1.3.6.1.4.1.4874.2.2.58.1.1.1.1.3 |
juniAtm1483ProfileVccServiceCategoryrw Enumeration .1.3.6.1.4.1.4874.2.2.58.1.1.1.1.4 |
juniAtm1483ProfileVccPcrrw Gauge32 UNITS "kilo-bits per second" .1.3.6.1.4.1.4874.2.2.58.1.1.1.1.5 |
juniAtm1483ProfileVccScrrw Gauge32 UNITS "kilo-bits per second" .1.3.6.1.4.1.4874.2.2.58.1.1.1.1.6 |
juniAtm1483ProfileVccMbsrw Gauge32 UNITS "cells" .1.3.6.1.4.1.4874.2.2.58.1.1.1.1.7 |
juniAtm1483ProfileIfAliasrw DisplayString .1.3.6.1.4.1.4874.2.2.58.1.1.1.1.8 |
juniAtm1483ProfileAdvisoryRxSpeedrw Integer32 .1.3.6.1.4.1.4874.2.2.58.1.1.1.1.9 |
juniAtm1483ProfileVccOamAdminStatusrw Enumeration .1.3.6.1.4.1.4874.2.2.58.1.1.1.1.10 |
juniAtm1483ProfileVccOamLoopbackFrequencyrw Unsigned32 .1.3.6.1.4.1.4874.2.2.58.1.1.1.1.11 |
juniAtm1483ProfileVcClassNamerw DisplayString .1.3.6.1.4.1.4874.2.2.58.1.1.1.1.12 |
juniAtm1483ProfileAutoConfTable SEQUENCE OF JuniAtm1483ProfileAutoConfEntry .1.3.6.1.4.1.4874.2.2.58.1.1.2 |
juniAtm1483ProfileAutoConfEntry JuniAtm1483ProfileAutoConfEntry .1.3.6.1.4.1.4874.2.2.58.1.1.2.1 |
juniAtm1483ProfileAutoConfId Unsigned32 .1.3.6.1.4.1.4874.2.2.58.1.1.2.1.1 |
juniAtm1483ProfileAutoConfEncaps JuniProfileIfEncaps (Juniper-PROFILE-MIB) .1.3.6.1.4.1.4874.2.2.58.1.1.2.1.2 |
juniAtm1483ProfileAutoConfEnablerw JuniEnable (Juniper-TC) .1.3.6.1.4.1.4874.2.2.58.1.1.2.1.3 |
juniAtm1483ProfileAutoConfLockoutMinrw Integer32 .1.3.6.1.4.1.4874.2.2.58.1.1.2.1.4 |
juniAtm1483ProfileAutoConfLockoutMaxrw Integer32 .1.3.6.1.4.1.4874.2.2.58.1.1.2.1.5 |
juniAtm1483ProfileNestedProfileTable SEQUENCE OF JuniAtm1483ProfileNestedProfileEntry .1.3.6.1.4.1.4874.2.2.58.1.1.3 |
juniAtm1483ProfileNestedProfileEntry JuniAtm1483ProfileNestedProfileEntry .1.3.6.1.4.1.4874.2.2.58.1.1.3.1 |
juniAtm1483ProfileNestedProfileId Unsigned32 .1.3.6.1.4.1.4874.2.2.58.1.1.3.1.1 |
juniAtm1483ProfileNestedProfileEncaps JuniProfileIfEncaps (Juniper-PROFILE-MIB) .1.3.6.1.4.1.4874.2.2.58.1.1.3.1.2 |
juniAtm1483ProfileNestedProfileUpperIfProfileNamerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4874.2.2.58.1.1.3.1.3 |
juniAtm1483ProfileSubscriberTable SEQUENCE OF JuniAtm1483ProfileSubscriberEntry .1.3.6.1.4.1.4874.2.2.58.1.1.4 |
juniAtm1483ProfileSubscriberEntry JuniAtm1483ProfileSubscriberEntry .1.3.6.1.4.1.4874.2.2.58.1.1.4.1 |
juniAtm1483ProfileSubscriberId Unsigned32 .1.3.6.1.4.1.4874.2.2.58.1.1.4.1.1 |
juniAtm1483ProfileSubscriberEncaps JuniProfileIfEncaps (Juniper-PROFILE-MIB) .1.3.6.1.4.1.4874.2.2.58.1.1.4.1.2 |
juniAtm1483ProfileSubscriberNamePrefixrw JuniEnable (Juniper-TC) .1.3.6.1.4.1.4874.2.2.58.1.1.4.1.3 |
juniAtm1483ProfileSubscriberNamerw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4874.2.2.58.1.1.4.1.4 |
juniAtm1483ProfileSubscriberPasswordPrefixrw JuniEnable (Juniper-TC) .1.3.6.1.4.1.4874.2.2.58.1.1.4.1.5 |
juniAtm1483ProfileSubscriberPasswordrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4874.2.2.58.1.1.4.1.6 |
juniAtm1483ProfileSubscriberDomainrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.4874.2.2.58.1.1.4.1.7 |
juniAtm1483ProfileConformance OBJECT IDENTIFIER .1.3.6.1.4.1.4874.2.2.58.4 |
juniAtm1483ProfileCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.4874.2.2.58.4.1 |
juniAtm1483ProfileComplianceobsolete Unknown .1.3.6.1.4.1.4874.2.2.58.4.1.1 |
juniAtm1483ProfileCompliance2obsolete Unknown .1.3.6.1.4.1.4874.2.2.58.4.1.2 |
juniAtm1483ProfileCompliance3obsolete Unknown .1.3.6.1.4.1.4874.2.2.58.4.1.3 |
juniAtm1483ProfileCompliance4 Unknown .1.3.6.1.4.1.4874.2.2.58.4.1.4 |
juniAtm1483ProfileGroups OBJECT IDENTIFIER .1.3.6.1.4.1.4874.2.2.58.4.2 |
juniAtm1483ProfileGroupobsolete Unknown .1.3.6.1.4.1.4874.2.2.58.4.2.1 |
juniAtm1483ProfileGroup2obsolete Unknown .1.3.6.1.4.1.4874.2.2.58.4.2.2 |
juniAtm1483ProfileGroup3obsolete Unknown .1.3.6.1.4.1.4874.2.2.58.4.2.3 |
juniAtm1483ProfileGroup4obsolete Unknown .1.3.6.1.4.1.4874.2.2.58.4.2.4 |
juniAtm1483ProfileGroup5obsolete Unknown .1.3.6.1.4.1.4874.2.2.58.4.2.5 |
juniAtm1483ProfileGroup6 Unknown .1.3.6.1.4.1.4874.2.2.58.4.2.6 |
Juniper-ATM-1483-Profile-MIB Technical Reference Overview
The Juniper-ATM-1483-Profile-MIB SNMP MIB module published by Unisphere defines 51 managed OID objects, including 37 scalar/column metrics, 4 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.4874.2.2.58. Key tabular structures include juniAtm1483ProfileAutoConfTable, juniAtm1483ProfileNestedProfileTable, juniAtm1483ProfileSubscriberTable, juniAtm1483ProfileTable.
Key OID Definitions in Juniper-ATM-1483-Profile-MIB
.1.3.6.1.4.1.4874.2.2.58The ATM Profile MIB for the Juniper Networks, Inc. enterprise.
.1.3.6.1.4.1.4874.2.2.58.1.1.2Configures recognition of incoming data encapsulation types that trigger autoconfiguration on an interface.
.1.3.6.1.4.1.4874.2.2.58.1.1.3Specifies nested profiles for incoming data encapsulation types. Entries in this table are created/deleted as a side-effect of corresponding operations to the juniProfileNameTable in the Juniper-PROFILE-MIB.
.1.3.6.1.4.1.4874.2.2.58.1.1.4Configures subscriber identity used in circumstances where the remote subscriber's identity cannot be queried directly (e.g. dynamic IPoA operation). Entries in this table are created/deleted as a side-effect of corresponding operations to the juniProfileNameTable in the Juniper-PROFILE-MIB.
.1.3.6.1.4.1.4874.2.2.58.1.1.1This table contains profiles for configuring bulk ATM circuits. Entries in this table are created/deleted as a side-effect of corresponding operations to the juniProfileNameTable in the Juniper-PROFILE-MIB.
.1.3.6.1.4.1.4874.2.2.58.4.1.1Obsolete compliance statement for entities which implement the Juniper ATM Profile MIB. This statement became obsolete when ifALias support was added to profile entries.
.1.3.6.1.4.1.4874.2.2.58.4.1.2Obsolete compliance statement for entities which implement the Juniper ATM Profile MIB. This statement became obsolete when lockout objects were added to juniAtm1483ProfileAutoConfTable.
.1.3.6.1.4.1.4874.2.2.58.4.1.3Obsolete compliance statement for entities which implement the Juniper ATM Profile MIB.
.1.3.6.1.4.1.4874.2.2.58.4.1.4The compliance statement for entities which implement the Juniper ATM Profile MIB.
.1.3.6.1.4.1.4874.2.2.58.4.2.1Obsolete collection of objects providing management of profile functionality for ATM subinterfaces in a Juniper product. This group became obsolete when ifALias support was added to profile entries.
.1.3.6.1.4.1.4874.2.2.58.4.2.2Obolete collection of objects providing management of profile functionalityfor ATM subinterfaces in a Juniper product. This group became obsolete when OAM support was added to profile entries.
.1.3.6.1.4.1.4874.2.2.58.4.2.3Obsolete collection of objects providing management of profile functionality for ATM subinterfaces in a Juniper product. This group became obsolete when ifALias support was added to profile entries.
.1.3.6.1.4.1.4874.2.2.58.4.2.4Obsolete collection of objects providing management of profile functionality for ATM subinterfaces in a Juniper product. This group became obsolete when Encapsulation Type Lockout objects were added to profile entries.
.1.3.6.1.4.1.4874.2.2.58.4.2.5Obsolete collection of objects providing management of profile functionality for ATM subinterfaces in a Juniper product.
.1.3.6.1.4.1.4874.2.2.58.4.2.6A collection of objects providing management of profile functionality for ATM subinterfaces in a Juniper product.
.1.3.6.1.4.1.4874.2.2.58.1.1.1.1.9Advisory receive speed, in kilobits per second (kbps), of this subinterface. This object has no impact on forwarding performance but may be used as a hint for the underlying circuit receive speed. A value of 0 indicates that this feature is not enabled.
.1.3.6.1.4.1.4874.2.2.58.1.1.2.1.3When enabled, permits autoconfiguration of the specified interface when the specified encapsulation is recognized in an incoming data frame. This parameter can only be set when juniAtm1483ProfileAutoConfEncaps is configured to one of the following values: ip(0), ppp(1) pppoe(17), bridgedEthernet(19)
.1.3.6.1.4.1.4874.2.2.58.1.1.2.1.2The encapsulating protocol type to which the autconfiguration information in this entry applies. The valid values are: ip(0), ppp(1), pppoe(17), bridgedEthernet(19)
.1.3.6.1.4.1.4874.2.2.58.1.1.2.1Configures recognition of an incoming data encapsulation type that triggers autoconfiguration on an interface.
.1.3.6.1.4.1.4874.2.2.58.1.1.2.1.1The integer identifier associated with this profile. A value for this identifier is determined by locating or creating a profile name in the juniProfileNameTable.
.1.3.6.1.4.1.4874.2.2.58.1.1.2.1.5The upper bound, in seconds, of the time range used to specify the duration of the lockout of the encapsulation type from recognition for the specified interface. This value must equal or exceed the value for juniAtm1483ProfileAutoConfLockoutMin. This only takes effect if juniAtm1483ProfileAutoConfEnable is set to enable for the encapsulation type for this interface. The ability to lockout the specified encapsulation type from recognition in the event of an error in creating an interface of the encapsulation type is enabled by default. The initial lockout duration is juniAtm1483ProfileAutoConfLockoutMin and increases exponentially for each failure that occurs for the specified encapsulation type for the specified interface within the greater of 15 minutes and this object's value. The lockout duration for the specified encapsulation type will not exceed this object's value. If the time between creation errors for the specified encapsulation type for the specified interface is greater than the greater of 15 minutes and this object's value, then the lockout duration reverts to juniAtm1483ProfileAutoConfLockoutMin. To disable the ability to lockout the specified encapsulation type from recognition in the event of an error in creating an interface of the encapsulation type for the specified interface, the value of this object and juniAtm1483ProfileAutoConfLockoutMin must be set to 0. It is not recommended that this lockout feature be disabled except for debugging purposes.
.1.3.6.1.4.1.4874.2.2.58.1.1.2.1.4The lower bound, in seconds, of the time range used to specify the duration of the lockout of the encapsulation type from recognition for the specified interface. This only takes effect if juniAtm1483ProfileAutoConfEnable is set to enable for the encapsulation type for this interface. The ability to lockout the specified encapsulation type from recognition in the event of an error in creating an interface of the encapsulation type is enabled by default. The initial lockout duration is this object's value and increases exponentially for each failure that occurs for the specified encapsulation type for the specified interface within the greater of 15 minutes and juniAtm1483ProfileAutoConfLockoutMax. The lockout duration for the specified encapsulation type will not exceed juniAtm1483ProfileAutoConfLockoutMax. If the time between creation errors for the specified encapsulation type for the specified interface is greater than the greater of 15 minutes and juniAtm1483ProfileAutoConfLockoutMax, then the lockout duration reverts to this object's value. To disable the ability to lockout the specified encapsulation type from recognition in the event of an error in creating an interface of the encapsulation type for the specified interface, the value of this object and juniAtm1483ProfileAutoConfLockoutMax must be set to 0. It is not recommended that this lockout feature be disabled except for debugging purposes.
.1.3.6.1.4.1.4874.2.2.58.1.1.1.1A profile describing VCC configuration of an ATM subinterface.
.1.3.6.1.4.1.4874.2.2.58.1.1.1.1.1The integer identifier associated with this profile. A value for this identifier is determined by locating or creating a profile name in the juniProfileNameTable.
More MIBs from Unisphere
Browse all UnisphereMIBs →SNMP MIB module
The Unisphere-Data-BGP-MIB enables monitoring and management of Border Gateway Protocol (BGP) session states, routing table statistics, and neighbor relationships on Dell EMC Unisphere for Data storage systems. It provides access to standard BGP MIB objects for tracking peer connectivity, route advertisements, and protocol error counters within the storage network infrastructure.
The Juniper-RADIUS-CLIENT-MIB enables monitoring of RADIUS client authentication sessions, accounting records, and server reachability states on Juniper network devices. It provides specific counters and gauges for tracking authentication failures, successful logins, and RADIUS server response times to validate access control infrastructure health.
The Juniper-UNI-ATM-MIB module provides SNMP management capabilities for Juniper devices configured with Asynchronous Transfer Mode (ATM) user-network interfaces, enabling the monitoring of ATM-specific performance counters, interface states, and VPI/VCI traffic statistics.
The Juniper-AAA-MIB enables monitoring of authentication, authorization, and accounting events on Juniper Networks devices, specifically tracking user session states, login success/failure counts, and accounting record generation for RADIUS and TACACS+ protocols.
SNMP MIB module