INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB
The INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB module enables SNMP-based monitoring of power supply unit status, input voltage, output current, and temperature metrics on Intel Multi-Flex Server hardware. It facilitates real-time fault detection and redundancy management by exposing critical power subsystem telemetry for integration into network operations centers.
Imported Objects
Objects
41 total| Object Name |
|---|
multiFlexServerPwrMibModule MODULE-IDENTITY .1.3.6.1.4.1.343.2.19.1.1.1.17 |
pwrSupplyGroup Unknown .1.3.6.1.4.1.343.2.19.1.2.2.2.17 |
maxPwrSuppliesro Unsigned32 .1.3.6.1.4.1.343.2.19.1.2.10.17 |
numOfPwrSuppliesro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.27 |
numOfPwrBlanksro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.28 |
numOfPwrUnknownsro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.29 |
pwrSupplyPresenceMaskro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.37 |
pwrSupplyBlankPresenceMaskro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.38 |
pwrSupplyUnknownPresenceMaskro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.39 |
pwrSupplies OBJECT IDENTIFIER .1.3.6.1.4.1.343.2.19.1.2.10.207 |
pwrSupplyTable SEQUENCE OF PwrSupplyEntry .1.3.6.1.4.1.343.2.19.1.2.10.207.1 |
pwrSupplyEntry PwrSupplyEntry .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1 |
pwrSupplyIndexro Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.1 |
pwrSupplyPresencero Presence (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.2 |
pwrSupplyVendorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.3 |
pwrSupplyMfgDatero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.4 |
pwrSupplyDeviceNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.5 |
pwrSupplyPartro IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.6 |
pwrSupplySerialNoro IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.7 |
pwrSupplyMaximumPowerro Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.8 |
pwrSupplyNominalPowerro Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.9 |
pwrSupplyAssetTagro IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.10 |
pwrSupplyPowerLedro PowerLedStates (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.11 |
pwrSupplyFaultLedro FaultLedStates (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.12 |
pwrSupplyOpCodeVersionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.13 |
pwrSupplyBootBlockVersionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.14 |
pwrSupplyTypero Enumeration .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.15 |
pwrSupplyNumOfFansro INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.16 |
pwrSupplyInletTemperaturero INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.17 |
pwrSupplyOutputVdcro INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.18 |
pwrSupplyOutputAmpro INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.19 |
pwrSupplyOutputPickAmpro INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.20 |
pwrSupplyHotspotTempro INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.21 |
pwrSupplyEmbTempro INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.22 |
pwrSupplyStatusro Bits .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.23 |
pwrSupplyFanTable SEQUENCE OF PwrSupplyFanEntry .1.3.6.1.4.1.343.2.19.1.2.10.207.2 |
pwrSupplyFanEntry PwrSupplyFanEntry .1.3.6.1.4.1.343.2.19.1.2.10.207.2.1 |
pwrSupplyFanIndexro Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.1 |
pwrSupplyFanRpmMinimumro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.2 |
pwrSupplyFanRpmMaximumro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.3 |
pwrSupplyFanRpmReadingro Enumeration .1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.4 |
INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB Technical Reference Overview
The INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB SNMP MIB module published by Intel defines 41 managed OID objects, including 35 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.343.2.19.1.1.1.17. Key tabular structures include pwrSupplyFanTable, pwrSupplyTable.
Key OID Definitions in INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB
.1.3.6.1.4.1.343.2.19.1.1.1.17Power Supply Module of the Multi-Flex Server
.1.3.6.1.4.1.343.2.19.1.2.10.207.2Each row describes a Fan in a Fan FRU (indexed by the Fan FRU and by individual Fan) Current, this should include the 3 Fan FRUs (the two system Fan FRUs and the I/O Fan FRU) The number of Fans is dependent upon the FRU (see pwrSupplyFanFruNumOfFans in the fanFruTable for a particular FRU)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1Each row describes a Power Supply FRU in the chassis
.1.3.6.1.4.1.343.2.19.1.2.10.17Maximum number of Power Supply FRUs (including Power Supply Blanks and unknown) possible in this chassis.
.1.3.6.1.4.1.343.2.19.1.2.10.28The number of Power Supply Blanks (Fan only) in the system.
.1.3.6.1.4.1.343.2.19.1.2.10.27The number of Power Supplies (excludes blanks & unknown Frus in power supply slots).
.1.3.6.1.4.1.343.2.19.1.2.10.29The number of FRUs occupying power supply slots that are neither recognized as power supplies, nor blanks.
.1.3.6.1.4.1.343.2.19.1.2.10.38ASCII representation of bit string reflecting the presence of a recognized fan blanks in the power supply slots with the left most 'bit' being bit 1 and maxPwrSupplies bits being represented. This excludes both recognized and unrecognized power supplies. Thus, '0010' would express that power supply FRU 3 is a recognized fan blank present
.1.3.6.1.4.1.343.2.19.1.2.2.2.17Description.
.1.3.6.1.4.1.343.2.19.1.2.10.37ASCII representation of bit string reflecting the presence of a recognized power supply in the power supply slots with the left most 'bit' being bit 1 and maxPwrSupplies bits being represented. This excludes fan blanks and unrecognized FRUs. Thus, '0101' would express that power supply FRUs 2 & 4 are recognized power supplies present
.1.3.6.1.4.1.343.2.19.1.2.10.39ASCII representation of bit string reflecting the presence of a unrecognized FRUs in the power supply slots with the left most 'bit' being bit 1 and maxPwrSupplies bits being represented. This excludes recognized power supplies and fan blanks. Thus, '1000' would express that an unrecognized FRU is in the power supply slot 1 is present
.1.3.6.1.4.1.343.2.19.1.2.10.207Container for Power Supply specific information as well as all components logically contained within.
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.10Asset Tag # of device
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.14BMC Firmware version on the Fan Blank (only)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.5Device Name
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.22Power supply's EMB Temperature in degrees Celsius degrees Celsius - when power supply is present notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknown
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1..
.1.3.6.1.4.1.343.2.19.1.2.10.207.2.1..
.1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.1which pwrSupplyFan within a FRU we're talking about
.1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.3Maximum settable RPM Potentially to be removed - See Murali/Niel
.1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.2Minimum settable RPM Potentially to be removed - See Murali/Niel
.1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.4Fan's current RPM reading: 0 - Fan not spinning unknown - Indeterminate data (no communications, or unknown device present) notApplicable - Not present
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.12State of the Fault LED on the Power Supply (and optionally intiate identification)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.21Power supply's Hotspot Temperature in degrees Celsius degrees Celsius - when power supply is present notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknown
More MIBs from Intel
Browse all IntelMIBs →Standard SNMP MIB module defining data structures for INTELCORPORATIONBASEBOARD-MIB.
Standard SNMP MIB module defining data structures for INTELCORPORATIONBASEBOARDMAPPER-MIB.
Standard SNMP MIB module defining data structures for INTELCORPORATIONBASEBOARD2-MIB.
SNMP MIB module
The INTEL-SERVER-BASEBOARD7 MIB module enables SNMP monitoring and management of Intel server baseboard components, specifically providing read access to hardware sensor data, configurable threshold settings for alerts, and event notifications via the NOTIFICATION-TYPE construct.
SNMP MIB module