INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB
The INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB module enables SNMP-based monitoring of power supply unit status, input voltage, output current, and temperature metrics on Intel Multi-Flex Server hardware. It facilitates real-time fault detection and redundancy management by exposing critical power subsystem telemetry for integration into network operations centers.
Imported Objects
Objects
41 total| Object Name |
|---|
multiFlexServerPwrMibModulePower Supply Module of the Multi-Flex Server MODULE-IDENTITY .1.3.6.1.4.1.343.2.19.1.1.1.17 |
pwrSupplyGroupDescription. Unknown .1.3.6.1.4.1.343.2.19.1.2.2.2.17 |
maxPwrSuppliesMaximum number of Power Supply FRUs (including Power Supply Blanks and unknown) possible in this chassis.ro Unsigned32 .1.3.6.1.4.1.343.2.19.1.2.10.17 |
numOfPwrSuppliesThe number of Power Supplies (excludes blanks & unknown Frus in power supply slots).ro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.27 |
numOfPwrBlanksThe number of Power Supply Blanks (Fan only) in the system.ro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.28 |
numOfPwrUnknownsThe number of FRUs occupying power supply slots that are neither recognized as power supplies, nor blanks.ro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.29 |
pwrSupplyPresenceMaskASCII representation of bit string reflecting the presence of a recognized power supply in the power supply slots with the left most 'bit' being bit 1 and maxPwrSupplies bits being represented. This excludes fan blanks and unrecognized FRUs. Thus, '0101' would express that power supply FRUs 2 & 4 are recognized power supplies presentro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.37 |
pwrSupplyBlankPresenceMaskASCII representation of bit string reflecting the presence of a recognized fan blanks in the power supply slots with the left most 'bit' being bit 1 and maxPwrSupplies bits being represented. This excludes both recognized and unrecognized power supplies. Thus, '0010' would express that power supply FRU 3 is a recognized fan blank presentro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.38 |
pwrSupplyUnknownPresenceMaskASCII representation of bit string reflecting the presence of a unrecognized FRUs in the power supply slots with the left most 'bit' being bit 1 and maxPwrSupplies bits being represented. This excludes recognized power supplies and fan blanks. Thus, '1000' would express that an unrecognized FRU is in the power supply slot 1 is presentro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.39 |
pwrSuppliesContainer for Power Supply specific information as well as all components logically contained within. OBJECT IDENTIFIER .1.3.6.1.4.1.343.2.19.1.2.10.207 |
pwrSupplyTableEach row describes a Power Supply FRU in the chassis SEQUENCE OF PwrSupplyEntry .1.3.6.1.4.1.343.2.19.1.2.10.207.1 |
pwrSupplyEntry.. PwrSupplyEntry .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1 |
pwrSupplyIndexcolumn used to identify a particular Power Supply.ro Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.1 |
pwrSupplyPresenceFlag whether something is occupying the the power supply slot (being either a power supply, a power supply blank, or unknown device) pwrSupplyType within this row should be consulted to determine what is occupying the slot.ro Presence (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.2 |
pwrSupplyVendorDevice manufacturerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.3 |
pwrSupplyMfgDateManufacture date/timero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.4 |
pwrSupplyDeviceNameDevice Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.5 |
pwrSupplyPartDevice Part Numberro IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.6 |
pwrSupplySerialNoDevice Serial Numberro IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.7 |
pwrSupplyMaximumPowerStatic maximum power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Maximum power generation/consumption not known or specifiedro Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.8 |
pwrSupplyNominalPowerStatic Nominal power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Nominal power generation/consumption not known or specifiedro Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.9 |
pwrSupplyAssetTagAsset Tag # of devicero IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.10 |
pwrSupplyPowerLedState of the Power LED on the Power Supplyro PowerLedStates (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.11 |
pwrSupplyFaultLedState of the Fault LED on the Power Supply (and optionally intiate identification)ro FaultLedStates (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.12 |
pwrSupplyOpCodeVersionBMC Firmware version on the Fan Blank (only)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.13 |
pwrSupplyBootBlockVersionBMC Firmware version on the Fan Blank (only)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.14 |
pwrSupplyTypeEnumeration telling what kind of power supply FRU is in the slotro Enumeration .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.15 |
pwrSupplyNumOfFansNumber of Fans contained within this FRU May be static data given the FRUro INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.16 |
pwrSupplyInletTemperaturePower supply Fan blank FRU Inlet Temperature in Degrees Celsius (not applicable to power supplies that do not have an Inlet Temperaturero INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.17 |
pwrSupplyOutputVdcPower supply's output voltage in millivolts notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknownro INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.18 |
pwrSupplyOutputAmpPower supply's output amperage in milliamps notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknownro INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.19 |
pwrSupplyOutputPickAmpPower supply's output pick amperage in milliiamps notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknownro INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.20 |
pwrSupplyHotspotTempPower supply's Hotspot Temperature in degrees Celsius degrees Celsius - when power supply is present notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknownro INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.21 |
pwrSupplyEmbTempPower supply's EMB Temperature in degrees Celsius degrees Celsius - when power supply is present notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknownro INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.22 |
pwrSupplyStatusPower supply's status bits (power supply only) This is used to provide multiple enumerations (by bits) of the status. E.g., powerSupplyOn(2) powerOK(3).ro Bits .1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.23 |
pwrSupplyFanTableEach row describes a Fan in a Fan FRU (indexed by the Fan FRU and by individual Fan) Current, this should include the 3 Fan FRUs (the two system Fan FRUs and the I/O Fan FRU) The number of Fans is dependent upon the FRU (see pwrSupplyFanFruNumOfFans in the fanFruTable for a particular FRU) SEQUENCE OF PwrSupplyFanEntry .1.3.6.1.4.1.343.2.19.1.2.10.207.2 |
pwrSupplyFanEntry.. PwrSupplyFanEntry .1.3.6.1.4.1.343.2.19.1.2.10.207.2.1 |
pwrSupplyFanIndexwhich pwrSupplyFan within a FRU we're talking aboutro Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.1 |
pwrSupplyFanRpmMinimumMinimum settable RPM Potentially to be removed - See Murali/Nielro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.2 |
pwrSupplyFanRpmMaximumMaximum settable RPM Potentially to be removed - See Murali/Nielro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.3 |
pwrSupplyFanRpmReadingFan's current RPM reading: 0 - Fan not spinning unknown - Indeterminate data (no communications, or unknown device present) notApplicable - Not presentro Enumeration .1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.4 |
More MIBs from Intel
Browse all IntelMIBs →Standard SNMP MIB module defining data structures for INTELCORPORATIONBASEBOARD-MIB.
Standard SNMP MIB module defining data structures for INTELCORPORATIONBASEBOARDMAPPER-MIB.
Standard SNMP MIB module defining data structures for INTELCORPORATIONBASEBOARD2-MIB.
SNMP MIB module
The INTEL-SERVER-BASEBOARD7 MIB module enables SNMP monitoring and management of Intel server baseboard components, specifically providing read access to hardware sensor data, configurable threshold settings for alerts, and event notifications via the NOTIFICATION-TYPE construct.
SNMP MIB module