Home/Catalog/INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB

INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB

AI MIB Summary

The INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB module enables SNMP-based monitoring of power supply unit status, input voltage, output current, and temperature metrics on Intel Multi-Flex Server hardware. It facilitates real-time fault detection and redundancy management by exposing critical power subsystem telemetry for integration into network operations centers.

Power Supply Module of the Multi-Flex Server
Main OID:
multiFlexServerPwrMibModule.1.3.6.1.4.1.343.2.19.1.1.1.17
41
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

41 total
Object Name
multiFlexServerPwrMibModule
MODULE-IDENTITY
.1.3.6.1.4.1.343.2.19.1.1.1.17
pwrSupplyGroup
Unknown
.1.3.6.1.4.1.343.2.19.1.2.2.2.17
maxPwrSuppliesro
Unsigned32
.1.3.6.1.4.1.343.2.19.1.2.10.17
numOfPwrSuppliesro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.27
numOfPwrBlanksro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.28
numOfPwrUnknownsro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.29
pwrSupplyPresenceMaskro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.37
pwrSupplyBlankPresenceMaskro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.38
pwrSupplyUnknownPresenceMaskro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.39
pwrSupplies
OBJECT IDENTIFIER
.1.3.6.1.4.1.343.2.19.1.2.10.207
pwrSupplyTable
SEQUENCE OF PwrSupplyEntry
.1.3.6.1.4.1.343.2.19.1.2.10.207.1
pwrSupplyEntry
PwrSupplyEntry
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1
pwrSupplyIndexro
Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.1
pwrSupplyPresencero
Presence (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.2
pwrSupplyVendorro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.3
pwrSupplyMfgDatero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.4
pwrSupplyDeviceNamero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.5
pwrSupplyPartro
IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.6
pwrSupplySerialNoro
IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.7
pwrSupplyMaximumPowerro
Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.8
pwrSupplyNominalPowerro
Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.9
pwrSupplyAssetTagro
IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.10
pwrSupplyPowerLedro
PowerLedStates (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.11
pwrSupplyFaultLedro
FaultLedStates (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.12
pwrSupplyOpCodeVersionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.13
pwrSupplyBootBlockVersionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.14
pwrSupplyTypero
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.15
pwrSupplyNumOfFansro
INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.16
pwrSupplyInletTemperaturero
INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.17
pwrSupplyOutputVdcro
INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.18
pwrSupplyOutputAmpro
INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.19
pwrSupplyOutputPickAmpro
INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.20
pwrSupplyHotspotTempro
INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.21
pwrSupplyEmbTempro
INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.22
pwrSupplyStatusro
Bits
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.23
pwrSupplyFanTable
SEQUENCE OF PwrSupplyFanEntry
.1.3.6.1.4.1.343.2.19.1.2.10.207.2
pwrSupplyFanEntry
PwrSupplyFanEntry
.1.3.6.1.4.1.343.2.19.1.2.10.207.2.1
pwrSupplyFanIndexro
Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.1
pwrSupplyFanRpmMinimumro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.2
pwrSupplyFanRpmMaximumro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.3
pwrSupplyFanRpmReadingro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.4

INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB Technical Reference Overview

The INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB SNMP MIB module published by Intel defines 41 managed OID objects, including 35 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.343.2.19.1.1.1.17. Key tabular structures include pwrSupplyFanTable, pwrSupplyTable.

Key OID Definitions in INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB

multiFlexServerPwrMibModuleMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.343.2.19.1.1.1.17

Power Supply Module of the Multi-Flex Server

pwrSupplyFanTableSEQUENCEnot-accessible
.1.3.6.1.4.1.343.2.19.1.2.10.207.2

Each row describes a Fan in a Fan FRU (indexed by the Fan FRU and by individual Fan) Current, this should include the 3 Fan FRUs (the two system Fan FRUs and the I/O Fan FRU) The number of Fans is dependent upon the FRU (see pwrSupplyFanFruNumOfFans in the fanFruTable for a particular FRU)

pwrSupplyTableSEQUENCEnot-accessible
.1.3.6.1.4.1.343.2.19.1.2.10.207.1

Each row describes a Power Supply FRU in the chassis

maxPwrSuppliesUnsigned32read-only
.1.3.6.1.4.1.343.2.19.1.2.10.17

Maximum number of Power Supply FRUs (including Power Supply Blanks and unknown) possible in this chassis.

numOfPwrBlanksInteger32read-only
.1.3.6.1.4.1.343.2.19.1.2.10.28

The number of Power Supply Blanks (Fan only) in the system.

numOfPwrSuppliesInteger32read-only
.1.3.6.1.4.1.343.2.19.1.2.10.27

The number of Power Supplies (excludes blanks & unknown Frus in power supply slots).

numOfPwrUnknownsInteger32read-only
.1.3.6.1.4.1.343.2.19.1.2.10.29

The number of FRUs occupying power supply slots that are neither recognized as power supplies, nor blanks.

pwrSupplyBlankPresenceMaskDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.38

ASCII representation of bit string reflecting the presence of a recognized fan blanks in the power supply slots with the left most 'bit' being bit 1 and maxPwrSupplies bits being represented. This excludes both recognized and unrecognized power supplies. Thus, '0010' would express that power supply FRU 3 is a recognized fan blank present

pwrSupplyGroupunknownnot-accessible
.1.3.6.1.4.1.343.2.19.1.2.2.2.17

Description.

pwrSupplyPresenceMaskDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.37

ASCII representation of bit string reflecting the presence of a recognized power supply in the power supply slots with the left most 'bit' being bit 1 and maxPwrSupplies bits being represented. This excludes fan blanks and unrecognized FRUs. Thus, '0101' would express that power supply FRUs 2 & 4 are recognized power supplies present

pwrSupplyUnknownPresenceMaskDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.39

ASCII representation of bit string reflecting the presence of a unrecognized FRUs in the power supply slots with the left most 'bit' being bit 1 and maxPwrSupplies bits being represented. This excludes recognized power supplies and fan blanks. Thus, '1000' would express that an unrecognized FRU is in the power supply slot 1 is present

pwrSuppliesOBJECTnot-accessible
.1.3.6.1.4.1.343.2.19.1.2.10.207

Container for Power Supply specific information as well as all components logically contained within.

pwrSupplyAssetTagIdromBinary16read-only
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.10

Asset Tag # of device

pwrSupplyBootBlockVersionDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.14

BMC Firmware version on the Fan Blank (only)

pwrSupplyDeviceNameDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.5

Device Name

pwrSupplyEmbTempINT32withExceptionread-only
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.22

Power supply's EMB Temperature in degrees Celsius degrees Celsius - when power supply is present notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknown

pwrSupplyEntryPwrSupplyEntrynot-accessible
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1

..

pwrSupplyFanEntryPwrSupplyFanEntrynot-accessible
.1.3.6.1.4.1.343.2.19.1.2.10.207.2.1

..

pwrSupplyFanIndexIndexread-only
.1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.1

which pwrSupplyFan within a FRU we're talking about

pwrSupplyFanRpmMaximumInteger32read-only
.1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.3

Maximum settable RPM Potentially to be removed - See Murali/Niel

pwrSupplyFanRpmMinimumInteger32read-only
.1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.2

Minimum settable RPM Potentially to be removed - See Murali/Niel

pwrSupplyFanRpmReadingINTEGERread-only
.1.3.6.1.4.1.343.2.19.1.2.10.207.2.1.4

Fan's current RPM reading: 0 - Fan not spinning unknown - Indeterminate data (no communications, or unknown device present) notApplicable - Not present

pwrSupplyFaultLedFaultLedStatesread-only
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.12

State of the Fault LED on the Power Supply (and optionally intiate identification)

pwrSupplyHotspotTempINT32withExceptionread-only
.1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.21

Power supply's Hotspot Temperature in degrees Celsius degrees Celsius - when power supply is present notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknown

More MIBs from Intel

Browse all IntelMIBs →