INTELCORPORATION-MULTI-FLEX-SERVER-FAN-MIB
The INTELCORPORATION-MULTI-FLEX-SERVER-FAN-MIB enables SNMP-based monitoring and management of fan module status, operational state, and failure alarms on Intel Multi-Flex Server hardware. This module provides specific telemetry for fan speed, presence detection, and fault conditions to ensure thermal management integrity within the server chassis.
Imported Objects
Objects
30 total| Object Name |
|---|
multiFlexServerFanMibModule MODULE-IDENTITY .1.3.6.1.4.1.343.2.19.1.1.1.16 |
fanGroup Unknown .1.3.6.1.4.1.343.2.19.1.2.2.2.16 |
maxFanFrusro Unsigned32 .1.3.6.1.4.1.343.2.19.1.2.10.16 |
numOfFanFrusro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.26 |
fanFruPresenceMaskro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.36 |
fans OBJECT IDENTIFIER .1.3.6.1.4.1.343.2.19.1.2.10.206 |
fanFruTable SEQUENCE OF FanFruEntry .1.3.6.1.4.1.343.2.19.1.2.10.206.1 |
fanFruEntry FanFruEntry .1.3.6.1.4.1.343.2.19.1.2.10.206.1.1 |
fanFruIndexro Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.1 |
fanFruPresencero Presence (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.2 |
fanFruVendorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.3 |
fanFruMfgDatero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.4 |
fanFruDeviceNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.5 |
fanFruPartro IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.6 |
fanFruSerialNoro IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.7 |
fanFruMaximumPowerro Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.8 |
fanFruNominalPowerro Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.9 |
fanFruAssetTagro IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.10 |
fanFruPowerLedro PowerLedStates (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.11 |
fanFruFaultLedro FaultLedStates (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.12 |
fanFruOpCodeVersionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.13 |
fanFruBootBlockVersionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.14 |
fanFruNumOfFansro INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.15 |
fanFruInletTemperaturero INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.16 |
fanTable SEQUENCE OF FanEntry .1.3.6.1.4.1.343.2.19.1.2.10.206.2 |
fanEntry FanEntry .1.3.6.1.4.1.343.2.19.1.2.10.206.2.1 |
fanIndexro Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.206.2.1.1 |
fanRpmMinimumro Enumeration .1.3.6.1.4.1.343.2.19.1.2.10.206.2.1.2 |
fanRpmMaximumro Enumeration .1.3.6.1.4.1.343.2.19.1.2.10.206.2.1.3 |
fanRpmReadingro Enumeration .1.3.6.1.4.1.343.2.19.1.2.10.206.2.1.4 |
INTELCORPORATION-MULTI-FLEX-SERVER-FAN-MIB Technical Reference Overview
The INTELCORPORATION-MULTI-FLEX-SERVER-FAN-MIB SNMP MIB module published by Intel defines 30 managed OID objects, including 24 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.343.2.19.1.1.1.16. Key tabular structures include fanFruTable, fanTable.
Key OID Definitions in INTELCORPORATION-MULTI-FLEX-SERVER-FAN-MIB
.1.3.6.1.4.1.343.2.19.1.1.1.16Fan Module of the Multi-Flex Server
.1.3.6.1.4.1.343.2.19.1.2.10.206.1Each row describes a Fan FRU in the chassis Current, this should include the 3 Fan FRUs (the two system Fan FRUs and the I/O Fan FRU) All system FRUs rows will be present
.1.3.6.1.4.1.343.2.19.1.2.10.206.2Each row describes a Fan in a Fan FRU (indexed by the Fan FRU and by individual Fan) Current, this should include the 3 Fan FRUs (the two system Fan FRUs and the I/O Fan FRU) The number of Fans is dependent upon the FRU (see fanFruNumOfFans in the fanFruTable for a particular FRU)
.1.3.6.1.4.1.343.2.19.1.2.10.36ASCII representation of bit string reflecting the presence of the fans with the left most 'bit' being bit 1 and maxFans bits being represented. Thus, '11011' would express that all fans (of five fans) are present except fan 3
.1.3.6.1.4.1.343.2.19.1.2.2.2.16Description.
.1.3.6.1.4.1.343.2.19.1.2.10.16Maximum number of Fans possible in this chassis.
.1.3.6.1.4.1.343.2.19.1.2.10.26The number of Fans in the system.
.1.3.6.1.4.1.343.2.19.1.2.10.206.2.1..
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.10Asset Tag # of device
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.14Boot Block version on the Fan FRU
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.5Device Name
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1..
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.12State of the Fault LED on the Fan FRU
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.1column used to identify a particular Fan FRU.
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.16FRU Inlet Temperature in Degrees Celsius
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.8Static maximum power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Maximum power generation/consumption not known or specified
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.4Manufacture date/time
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.9Static Nominal power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Nominal power generation/consumption not known or specified
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.15Number of Fans contained within this FRU May be static data given the FRU
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.13Op code version on the Fan FRU
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.6Device Part Number
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.11State of the Power LED on the Fan FRU
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.2Flag whether this Fan FRU is present
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.7Device Serial Number
More MIBs from Intel
Browse all IntelMIBs →Standard SNMP MIB module defining data structures for INTELCORPORATIONBASEBOARD-MIB.
Standard SNMP MIB module defining data structures for INTELCORPORATIONBASEBOARDMAPPER-MIB.
Standard SNMP MIB module defining data structures for INTELCORPORATIONBASEBOARD2-MIB.
SNMP MIB module
The INTEL-SERVER-BASEBOARD7 MIB module enables SNMP monitoring and management of Intel server baseboard components, specifically providing read access to hardware sensor data, configurable threshold settings for alerts, and event notifications via the NOTIFICATION-TYPE construct.
SNMP MIB module