Home/Catalog/INTELCORPORATION-MULTI-FLEX-SERVER-FAN-MIB

INTELCORPORATION-MULTI-FLEX-SERVER-FAN-MIB

AI MIB Summary

The INTELCORPORATION-MULTI-FLEX-SERVER-FAN-MIB enables SNMP-based monitoring and management of fan module status, operational state, and failure alarms on Intel Multi-Flex Server hardware. This module provides specific telemetry for fan speed, presence detection, and fault conditions to ensure thermal management integrity within the server chassis.

Fan Module of the Multi-Flex Server
Main OID:
multiFlexServerFanMibModule.1.3.6.1.4.1.343.2.19.1.1.1.16
30
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

30 total
Object Name
multiFlexServerFanMibModule
MODULE-IDENTITY
.1.3.6.1.4.1.343.2.19.1.1.1.16
fanGroup
Unknown
.1.3.6.1.4.1.343.2.19.1.2.2.2.16
maxFanFrusro
Unsigned32
.1.3.6.1.4.1.343.2.19.1.2.10.16
numOfFanFrusro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.26
fanFruPresenceMaskro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.36
fans
OBJECT IDENTIFIER
.1.3.6.1.4.1.343.2.19.1.2.10.206
fanFruTable
SEQUENCE OF FanFruEntry
.1.3.6.1.4.1.343.2.19.1.2.10.206.1
fanFruEntry
FanFruEntry
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1
fanFruIndexro
Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.1
fanFruPresencero
Presence (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.2
fanFruVendorro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.3
fanFruMfgDatero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.4
fanFruDeviceNamero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.5
fanFruPartro
IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.6
fanFruSerialNoro
IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.7
fanFruMaximumPowerro
Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.8
fanFruNominalPowerro
Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.9
fanFruAssetTagro
IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.10
fanFruPowerLedro
PowerLedStates (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.11
fanFruFaultLedro
FaultLedStates (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.12
fanFruOpCodeVersionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.13
fanFruBootBlockVersionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.14
fanFruNumOfFansro
INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.15
fanFruInletTemperaturero
INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.16
fanTable
SEQUENCE OF FanEntry
.1.3.6.1.4.1.343.2.19.1.2.10.206.2
fanEntry
FanEntry
.1.3.6.1.4.1.343.2.19.1.2.10.206.2.1
fanIndexro
Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.206.2.1.1
fanRpmMinimumro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.206.2.1.2
fanRpmMaximumro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.206.2.1.3
fanRpmReadingro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.206.2.1.4

INTELCORPORATION-MULTI-FLEX-SERVER-FAN-MIB Technical Reference Overview

The INTELCORPORATION-MULTI-FLEX-SERVER-FAN-MIB SNMP MIB module published by Intel defines 30 managed OID objects, including 24 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.343.2.19.1.1.1.16. Key tabular structures include fanFruTable, fanTable.

Key OID Definitions in INTELCORPORATION-MULTI-FLEX-SERVER-FAN-MIB

multiFlexServerFanMibModuleMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.343.2.19.1.1.1.16

Fan Module of the Multi-Flex Server

fanFruTableSEQUENCEnot-accessible
.1.3.6.1.4.1.343.2.19.1.2.10.206.1

Each row describes a Fan FRU in the chassis Current, this should include the 3 Fan FRUs (the two system Fan FRUs and the I/O Fan FRU) All system FRUs rows will be present

fanTableSEQUENCEnot-accessible
.1.3.6.1.4.1.343.2.19.1.2.10.206.2

Each row describes a Fan in a Fan FRU (indexed by the Fan FRU and by individual Fan) Current, this should include the 3 Fan FRUs (the two system Fan FRUs and the I/O Fan FRU) The number of Fans is dependent upon the FRU (see fanFruNumOfFans in the fanFruTable for a particular FRU)

fanFruPresenceMaskDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.36

ASCII representation of bit string reflecting the presence of the fans with the left most 'bit' being bit 1 and maxFans bits being represented. Thus, '11011' would express that all fans (of five fans) are present except fan 3

fanGroupunknownnot-accessible
.1.3.6.1.4.1.343.2.19.1.2.2.2.16

Description.

maxFanFrusUnsigned32read-only
.1.3.6.1.4.1.343.2.19.1.2.10.16

Maximum number of Fans possible in this chassis.

numOfFanFrusInteger32read-only
.1.3.6.1.4.1.343.2.19.1.2.10.26

The number of Fans in the system.

fanEntryFanEntrynot-accessible
.1.3.6.1.4.1.343.2.19.1.2.10.206.2.1

..

fanFruAssetTagIdromBinary16read-only
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.10

Asset Tag # of device

fanFruBootBlockVersionDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.14

Boot Block version on the Fan FRU

fanFruDeviceNameDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.5

Device Name

fanFruEntryFanFruEntrynot-accessible
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1

..

fanFruFaultLedFaultLedStatesread-only
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.12

State of the Fault LED on the Fan FRU

fanFruIndexIndexread-only
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.1

column used to identify a particular Fan FRU.

fanFruInletTemperatureINT32withExceptionread-only
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.16

FRU Inlet Temperature in Degrees Celsius

fanFruMaximumPowerPowerread-only
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.8

Static maximum power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Maximum power generation/consumption not known or specified

fanFruMfgDateDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.4

Manufacture date/time

fanFruNominalPowerPowerread-only
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.9

Static Nominal power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Nominal power generation/consumption not known or specified

fanFruNumOfFansINT32withExceptionread-only
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.15

Number of Fans contained within this FRU May be static data given the FRU

fanFruOpCodeVersionDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.13

Op code version on the Fan FRU

fanFruPartIdromBinary16read-only
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.6

Device Part Number

fanFruPowerLedPowerLedStatesread-only
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.11

State of the Power LED on the Fan FRU

fanFruPresencePresenceread-only
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.2

Flag whether this Fan FRU is present

fanFruSerialNoIdromBinary16read-only
.1.3.6.1.4.1.343.2.19.1.2.10.206.1.1.7

Device Serial Number

More MIBs from Intel

Browse all IntelMIBs →