Home/Catalog/INTELCORPORATION-MULTI-FLEX-SERVER-DRIVE-MIB

INTELCORPORATION-MULTI-FLEX-SERVER-DRIVE-MIB

AI MIB Summary

The INTELCORPORATION-MULTI-FLEX-SERVER-DRIVE-MIB module facilitates SNMP-based monitoring and management of shared disk subsystems within Intel Multi-Flex Server environments, exposing critical drive health metrics such as status, capacity, and error counters.

Shared Disks Module of the Multi-Flex Server
Main OID:
multiFlexServerDrivesMibModule.1.3.6.1.4.1.343.2.19.1.1.1.15
51
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

51 total
Object Name
multiFlexServerDrivesMibModuleShared Disks Module of the Multi-Flex Server
MODULE-IDENTITY
.1.3.6.1.4.1.343.2.19.1.1.1.15
sDriveGroupDescription.
Unknown
.1.3.6.1.4.1.343.2.19.1.2.2.2.15
maxSharedDrivesMaximum number of Shared Drives possible in this chassisro
Unsigned32
.1.3.6.1.4.1.343.2.19.1.2.10.15
numOfSharedDrivesThe number of Shared Drives in the systemro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.25
sDrivePresenceMaskASCII representation of bit string reflecting the presence of the shared drives with the left most 'bit' being bit 1 and maxSharedDrives bits being represented. Thus, '11001111111111' would express that all the shared drives (of fourteen shared drives) are present with exception of drives 3 & 4ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.35
sharedDrivesContainer for Shared Drive specific information as well as all components logically contained within.
OBJECT IDENTIFIER
.1.3.6.1.4.1.343.2.19.1.2.10.205
driveBackplaneIDROM information from the Drive Backplane
OBJECT IDENTIFIER
.1.3.6.1.4.1.343.2.19.1.2.10.205.1
driveBackplaneVendorDevice manufacturerro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.1
driveBackplaneMfgDateManufacture date/timero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.2
driveBackplaneDeviceNameDevice Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.3
driveBackplanePartDevice Part Numberro
IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.4
driveBackplaneSerialNoDevice Serial Numberro
IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.5
driveBackplaneMaximumPowerStatic maximum power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Maximum power generation/consumption not known or specifiedro
Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.6
driveBackplaneNominalPowerStatic Nominal power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Nominal power generation/consumption not known or specifiedro
Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.7
driveBackplaneAssetTagAsset Tag # of devicero
IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.8
sharedDriveTableEach row describes a shared drive in the chassis
SEQUENCE OF SharedDriveEntry
.1.3.6.1.4.1.343.2.19.1.2.10.205.2
sharedDriveEntryThe parameters of a physical drive.
SharedDriveEntry
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1
sDriveSlotNumberThe slot number on the enclosure where the drive is located (drive ID)ro
Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.1
sDrivePresencecolumn used to flag the existence of a particular FRUro
Presence (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.2
sDriveInterfaceThe Drive Interface of the physical drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.3
sDriveModelNumberThe Model Number of the physical drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.4
sDriveSerialNumberThe Serial Number of the physical drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.5
sDriveFirmwareVersionThe Firmware Version of the physical drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.6
sDriveProtocolVersionThe Protocol Version of the physical drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.7
sDriveOperationalStatusThe Operational Status of the physical drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.8
sDriveConditionThe condition of the physical drive, e.g. PFA.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.9
sDriveOperationThe current operation on the physical drive, e.g. mediapatrolling, migrating.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.10
sDriveConfigurationThe configuration on the physical drive, e.g. array %d seqno %d, or dedicated spare.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.11
sDriveStoragePoolIDThe drive array id, if the physical drive is part of a drive array; the spare id, if the drive is a spare.ro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.12
sDriveSequenceNumberThe sequence number of the drive in the drive array. Valid only when the drive is part of a drive array.ro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.13
sDriveEnclosureIDThe id of the enclosure to which the drive is inserted.ro
INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.14
sDriveBlockSizeThe Block Size in bytes of the physical drive.ro
INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.15
sDrivePhysicalCapacityThe Physical Size in bytes of the physical drive.ro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.16
sDriveConfigurableCapacityThe Configurable Size in bytes of the physical drive.ro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.17
sDriveUsedCapacityThe Used Size in bytes of the physical drive.ro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.18
sDriveTypeThe type of the physical drive. e.g. SATA or SASro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.19
sharedDriveStatsTableA table of Physical Drive Statistics (augments sharedDriveTable)
SEQUENCE OF SharedDriveStatsEntry
.1.3.6.1.4.1.343.2.19.1.2.10.205.3
sharedDriveStatsEntryThe statistics of a physical drive since its last reset or statistics rest.
SharedDriveStatsEntry
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1
sDriveStatsDataTransferredThe total number of bytes of data transfered to and from the controller.ro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.1
sDriveStatsReadDataTransferredThe total number of bytes of data transfered from the controller.ro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.2
sDriveStatsWriteDataTransferredThe total number of bytes of data transfered to the controller.ro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.3
sDriveStatsNumOfErrorsThe total number of errors.ro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.4
sDriveStatsNumOfNonRWErrorsThe total number of non-RW errors.ro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.5
sDriveStatsNumOfReadErrorsThe total number of Read errors.ro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.6
sDriveStatsNumOfWriteErrorsThe total number of Write errors.ro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.7
sDriveStatsNumOfIORequestsThe total number of IO requests.ro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.8
sDriveStatsNumOfNonRWRequestsThe total number of non-RW requests.ro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.9
sDriveStatsNumOfReadRequestsThe total number of read requests.ro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.10
sDriveStatsNumOfWriteRequestsThe total number of write requests.ro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.11
sDriveStatsStartTimeThe time when the statistics date starts to accumulate since last statistics reset.ro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.12
sDriveStatsCollectionTimeThe time when the statistics data was collected or updated last time.ro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.13
INTELCORPORATION-MULTI-FLEX-SERVER-DRIVE-MIB - SNMP MIB Reference | MIBs Explorer