Home/Catalog/INTELCORPORATION-MULTI-FLEX-SERVER-DRIVE-MIB

INTELCORPORATION-MULTI-FLEX-SERVER-DRIVE-MIB

AI MIB Summary

The INTELCORPORATION-MULTI-FLEX-SERVER-DRIVE-MIB module facilitates SNMP-based monitoring and management of shared disk subsystems within Intel Multi-Flex Server environments, exposing critical drive health metrics such as status, capacity, and error counters.

Shared Disks Module of the Multi-Flex Server
Main OID:
multiFlexServerDrivesMibModule.1.3.6.1.4.1.343.2.19.1.1.1.15
51
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

51 total
Object Name
multiFlexServerDrivesMibModule
MODULE-IDENTITY
.1.3.6.1.4.1.343.2.19.1.1.1.15
sDriveGroup
Unknown
.1.3.6.1.4.1.343.2.19.1.2.2.2.15
maxSharedDrivesro
Unsigned32
.1.3.6.1.4.1.343.2.19.1.2.10.15
numOfSharedDrivesro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.25
sDrivePresenceMaskro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.35
sharedDrives
OBJECT IDENTIFIER
.1.3.6.1.4.1.343.2.19.1.2.10.205
driveBackplane
OBJECT IDENTIFIER
.1.3.6.1.4.1.343.2.19.1.2.10.205.1
driveBackplaneVendorro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.1
driveBackplaneMfgDatero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.2
driveBackplaneDeviceNamero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.3
driveBackplanePartro
IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.4
driveBackplaneSerialNoro
IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.5
driveBackplaneMaximumPowerro
Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.6
driveBackplaneNominalPowerro
Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.7
driveBackplaneAssetTagro
IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.8
sharedDriveTable
SEQUENCE OF SharedDriveEntry
.1.3.6.1.4.1.343.2.19.1.2.10.205.2
sharedDriveEntry
SharedDriveEntry
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1
sDriveSlotNumberro
Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.1
sDrivePresencero
Presence (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.2
sDriveInterfacero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.3
sDriveModelNumberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.4
sDriveSerialNumberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.5
sDriveFirmwareVersionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.6
sDriveProtocolVersionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.7
sDriveOperationalStatusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.8
sDriveConditionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.9
sDriveOperationro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.10
sDriveConfigurationro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.11
sDriveStoragePoolIDro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.12
sDriveSequenceNumberro
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.13
sDriveEnclosureIDro
INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.14
sDriveBlockSizero
INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.15
sDrivePhysicalCapacityro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.16
sDriveConfigurableCapacityro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.17
sDriveUsedCapacityro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.18
sDriveTypero
Enumeration
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.19
sharedDriveStatsTable
SEQUENCE OF SharedDriveStatsEntry
.1.3.6.1.4.1.343.2.19.1.2.10.205.3
sharedDriveStatsEntry
SharedDriveStatsEntry
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1
sDriveStatsDataTransferredro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.1
sDriveStatsReadDataTransferredro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.2
sDriveStatsWriteDataTransferredro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.3
sDriveStatsNumOfErrorsro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.4
sDriveStatsNumOfNonRWErrorsro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.5
sDriveStatsNumOfReadErrorsro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.6
sDriveStatsNumOfWriteErrorsro
Integer32
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.7
sDriveStatsNumOfIORequestsro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.8
sDriveStatsNumOfNonRWRequestsro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.9
sDriveStatsNumOfReadRequestsro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.10
sDriveStatsNumOfWriteRequestsro
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.11
sDriveStatsStartTimero
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.12
sDriveStatsCollectionTimero
Counter64
.1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.13

INTELCORPORATION-MULTI-FLEX-SERVER-DRIVE-MIB Technical Reference Overview

The INTELCORPORATION-MULTI-FLEX-SERVER-DRIVE-MIB SNMP MIB module published by Intel defines 51 managed OID objects, including 44 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.343.2.19.1.1.1.15. Key tabular structures include sharedDriveStatsTable, sharedDriveTable.

Key OID Definitions in INTELCORPORATION-MULTI-FLEX-SERVER-DRIVE-MIB

multiFlexServerDrivesMibModuleMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.343.2.19.1.1.1.15

Shared Disks Module of the Multi-Flex Server

sharedDriveStatsTableSEQUENCEnot-accessible
.1.3.6.1.4.1.343.2.19.1.2.10.205.3

A table of Physical Drive Statistics (augments sharedDriveTable)

sharedDriveTableSEQUENCEnot-accessible
.1.3.6.1.4.1.343.2.19.1.2.10.205.2

Each row describes a shared drive in the chassis

driveBackplaneAssetTagIdromBinary16read-only
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.8

Asset Tag # of device

driveBackplaneDeviceNameDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.3

Device Name

driveBackplaneMaximumPowerPowerread-only
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.6

Static maximum power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Maximum power generation/consumption not known or specified

driveBackplaneMfgDateDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.2

Manufacture date/time

driveBackplaneNominalPowerPowerread-only
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.7

Static Nominal power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Nominal power generation/consumption not known or specified

driveBackplanePartIdromBinary16read-only
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.4

Device Part Number

driveBackplaneSerialNoIdromBinary16read-only
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.5

Device Serial Number

driveBackplaneVendorDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.1

Device manufacturer

maxSharedDrivesUnsigned32read-only
.1.3.6.1.4.1.343.2.19.1.2.10.15

Maximum number of Shared Drives possible in this chassis

numOfSharedDrivesInteger32read-only
.1.3.6.1.4.1.343.2.19.1.2.10.25

The number of Shared Drives in the system

sDriveGroupunknownnot-accessible
.1.3.6.1.4.1.343.2.19.1.2.2.2.15

Description.

sDrivePresenceMaskDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.35

ASCII representation of bit string reflecting the presence of the shared drives with the left most 'bit' being bit 1 and maxSharedDrives bits being represented. Thus, '11001111111111' would express that all the shared drives (of fourteen shared drives) are present with exception of drives 3 & 4

driveBackplaneOBJECTnot-accessible
.1.3.6.1.4.1.343.2.19.1.2.10.205.1

IDROM information from the Drive Backplane

sDriveBlockSizeINT32withExceptionread-only
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.15

The Block Size in bytes of the physical drive.

sDriveConditionDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.9

The condition of the physical drive, e.g. PFA.

sDriveConfigurableCapacityCounter64read-only
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.17

The Configurable Size in bytes of the physical drive.

sDriveConfigurationDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.11

The configuration on the physical drive, e.g. array %d seqno %d, or dedicated spare.

sDriveEnclosureIDINT32withExceptionread-only
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.14

The id of the enclosure to which the drive is inserted.

sDriveFirmwareVersionDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.6

The Firmware Version of the physical drive.

sDriveInterfaceDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.3

The Drive Interface of the physical drive.

sDriveModelNumberDisplayStringread-only
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.4

The Model Number of the physical drive.

More MIBs from Intel