INTELCORPORATION-MULTI-FLEX-SERVER-DRIVE-MIB
The INTELCORPORATION-MULTI-FLEX-SERVER-DRIVE-MIB module facilitates SNMP-based monitoring and management of shared disk subsystems within Intel Multi-Flex Server environments, exposing critical drive health metrics such as status, capacity, and error counters.
Imported Objects
Objects
51 total| Object Name |
|---|
multiFlexServerDrivesMibModule MODULE-IDENTITY .1.3.6.1.4.1.343.2.19.1.1.1.15 |
sDriveGroup Unknown .1.3.6.1.4.1.343.2.19.1.2.2.2.15 |
maxSharedDrivesro Unsigned32 .1.3.6.1.4.1.343.2.19.1.2.10.15 |
numOfSharedDrivesro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.25 |
sDrivePresenceMaskro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.35 |
sharedDrives OBJECT IDENTIFIER .1.3.6.1.4.1.343.2.19.1.2.10.205 |
driveBackplane OBJECT IDENTIFIER .1.3.6.1.4.1.343.2.19.1.2.10.205.1 |
driveBackplaneVendorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.1.1 |
driveBackplaneMfgDatero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.1.2 |
driveBackplaneDeviceNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.1.3 |
driveBackplanePartro IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.1.4 |
driveBackplaneSerialNoro IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.1.5 |
driveBackplaneMaximumPowerro Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.1.6 |
driveBackplaneNominalPowerro Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.1.7 |
driveBackplaneAssetTagro IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.1.8 |
sharedDriveTable SEQUENCE OF SharedDriveEntry .1.3.6.1.4.1.343.2.19.1.2.10.205.2 |
sharedDriveEntry SharedDriveEntry .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1 |
sDriveSlotNumberro Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.1 |
sDrivePresencero Presence (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.2 |
sDriveInterfacero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.3 |
sDriveModelNumberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.4 |
sDriveSerialNumberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.5 |
sDriveFirmwareVersionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.6 |
sDriveProtocolVersionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.7 |
sDriveOperationalStatusro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.8 |
sDriveConditionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.9 |
sDriveOperationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.10 |
sDriveConfigurationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.11 |
sDriveStoragePoolIDro Enumeration .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.12 |
sDriveSequenceNumberro Enumeration .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.13 |
sDriveEnclosureIDro INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.14 |
sDriveBlockSizero INT32withException (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.15 |
sDrivePhysicalCapacityro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.16 |
sDriveConfigurableCapacityro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.17 |
sDriveUsedCapacityro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.18 |
sDriveTypero Enumeration .1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.19 |
sharedDriveStatsTable SEQUENCE OF SharedDriveStatsEntry .1.3.6.1.4.1.343.2.19.1.2.10.205.3 |
sharedDriveStatsEntry SharedDriveStatsEntry .1.3.6.1.4.1.343.2.19.1.2.10.205.3.1 |
sDriveStatsDataTransferredro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.1 |
sDriveStatsReadDataTransferredro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.2 |
sDriveStatsWriteDataTransferredro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.3 |
sDriveStatsNumOfErrorsro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.4 |
sDriveStatsNumOfNonRWErrorsro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.5 |
sDriveStatsNumOfReadErrorsro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.6 |
sDriveStatsNumOfWriteErrorsro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.7 |
sDriveStatsNumOfIORequestsro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.8 |
sDriveStatsNumOfNonRWRequestsro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.9 |
sDriveStatsNumOfReadRequestsro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.10 |
sDriveStatsNumOfWriteRequestsro Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.11 |
sDriveStatsStartTimero Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.12 |
sDriveStatsCollectionTimero Counter64 .1.3.6.1.4.1.343.2.19.1.2.10.205.3.1.13 |
INTELCORPORATION-MULTI-FLEX-SERVER-DRIVE-MIB Technical Reference Overview
The INTELCORPORATION-MULTI-FLEX-SERVER-DRIVE-MIB SNMP MIB module published by Intel defines 51 managed OID objects, including 44 scalar/column metrics, 2 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.343.2.19.1.1.1.15. Key tabular structures include sharedDriveStatsTable, sharedDriveTable.
Key OID Definitions in INTELCORPORATION-MULTI-FLEX-SERVER-DRIVE-MIB
.1.3.6.1.4.1.343.2.19.1.1.1.15Shared Disks Module of the Multi-Flex Server
.1.3.6.1.4.1.343.2.19.1.2.10.205.3A table of Physical Drive Statistics (augments sharedDriveTable)
.1.3.6.1.4.1.343.2.19.1.2.10.205.2Each row describes a shared drive in the chassis
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.8Asset Tag # of device
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.3Device Name
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.6Static maximum power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Maximum power generation/consumption not known or specified
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.2Manufacture date/time
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.7Static Nominal power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Nominal power generation/consumption not known or specified
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.4Device Part Number
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.5Device Serial Number
.1.3.6.1.4.1.343.2.19.1.2.10.205.1.1Device manufacturer
.1.3.6.1.4.1.343.2.19.1.2.10.15Maximum number of Shared Drives possible in this chassis
.1.3.6.1.4.1.343.2.19.1.2.10.25The number of Shared Drives in the system
.1.3.6.1.4.1.343.2.19.1.2.2.2.15Description.
.1.3.6.1.4.1.343.2.19.1.2.10.35ASCII representation of bit string reflecting the presence of the shared drives with the left most 'bit' being bit 1 and maxSharedDrives bits being represented. Thus, '11001111111111' would express that all the shared drives (of fourteen shared drives) are present with exception of drives 3 & 4
.1.3.6.1.4.1.343.2.19.1.2.10.205.1IDROM information from the Drive Backplane
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.15The Block Size in bytes of the physical drive.
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.9The condition of the physical drive, e.g. PFA.
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.17The Configurable Size in bytes of the physical drive.
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.11The configuration on the physical drive, e.g. array %d seqno %d, or dedicated spare.
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.14The id of the enclosure to which the drive is inserted.
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.6The Firmware Version of the physical drive.
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.3The Drive Interface of the physical drive.
.1.3.6.1.4.1.343.2.19.1.2.10.205.2.1.4The Model Number of the physical drive.
More MIBs from Intel
Browse all IntelMIBs →Standard SNMP MIB module defining data structures for INTELCORPORATIONBASEBOARD-MIB.
Standard SNMP MIB module defining data structures for INTELCORPORATIONBASEBOARDMAPPER-MIB.
Standard SNMP MIB module defining data structures for INTELCORPORATIONBASEBOARD2-MIB.
SNMP MIB module
The INTEL-SERVER-BASEBOARD7 MIB module enables SNMP monitoring and management of Intel server baseboard components, specifically providing read access to hardware sensor data, configurable threshold settings for alerts, and event notifications via the NOTIFICATION-TYPE construct.
SNMP MIB module