INTELCORPORATION-MULTI-FLEX-SERVER-CMM-MIB
The INTELCORPORATION-MULTI-FLEX-SERVER-CMM-MIB module provides SNMP-based monitoring and management capabilities for the Chassis Management Module (CMM) within Intel Multi-Flex Server chassis. It exposes critical hardware telemetry including system health status, power supply states, fan speeds, temperature sensors, and component inventory data for remote infrastructure supervision.
Imported Objects
Objects
25 total| Object Name |
|---|
multiFlexServerCmmMibModule MODULE-IDENTITY .1.3.6.1.4.1.343.2.19.1.1.1.11 |
cmmGroup Unknown .1.3.6.1.4.1.343.2.19.1.2.2.2.11 |
maxCmmsro Unsigned32 .1.3.6.1.4.1.343.2.19.1.2.10.11 |
numOfCmmsro Integer32 .1.3.6.1.4.1.343.2.19.1.2.10.21 |
cmmPresenceMaskro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.31 |
cmms OBJECT IDENTIFIER .1.3.6.1.4.1.343.2.19.1.2.10.201 |
firmwareBundleIdro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.201.1 |
cmmTable SEQUENCE OF CmmEntry .1.3.6.1.4.1.343.2.19.1.2.10.201.2 |
cmmEntry CmmEntry .1.3.6.1.4.1.343.2.19.1.2.10.201.2.1 |
cmmIndexro Index (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.1 |
cmmPresencero Presence (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.2 |
cmmVendorro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.3 |
cmmMfgDatero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.4 |
cmmDeviceNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.5 |
cmmPartro IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.6 |
cmmSerialNoro IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.7 |
cmmMaximumPowerro Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.8 |
cmmNominalPowerro Power (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.9 |
cmmAssetTagro IdromBinary16 (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.10 |
cmmExternalMacro PhysAddress (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.11 |
cmmChassisMacro PhysAddress (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.12 |
cmmPowerLedro PowerLedStates (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.13 |
cmmFaultLedro FaultLedStates (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.14 |
cmmPresenceLedrw PresenceLedStates (INTELCORPORATION-MULTI-FLEX-SERVER-TC) .1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.15 |
cmmEbfFirmwareVersionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.16 |
INTELCORPORATION-MULTI-FLEX-SERVER-CMM-MIB Technical Reference Overview
The INTELCORPORATION-MULTI-FLEX-SERVER-CMM-MIB SNMP MIB module published by Intel defines 25 managed OID objects, including 21 scalar/column metrics, 1 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.343.2.19.1.1.1.11. Key tabular structures include cmmTable.
Key OID Definitions in INTELCORPORATION-MULTI-FLEX-SERVER-CMM-MIB
.1.3.6.1.4.1.343.2.19.1.1.1.11CMM Module of the Multi-Flex Server
.1.3.6.1.4.1.343.2.19.1.2.10.201.2Each row describes a CMM in the chassis
.1.3.6.1.4.1.343.2.19.1.2.2.2.11Description.
.1.3.6.1.4.1.343.2.19.1.2.10.31ASCII representation of bit string reflecting the presence of the CMMs with the left most 'bit' being bit 1 and maxCmms bits being represented. Thus, '1' would express that CMM 1 (of the only one CMM) is present
.1.3.6.1.4.1.343.2.19.1.2.10.201.1Firmware bundle identification (Tag of all firmware/software versions on all FRUs)
.1.3.6.1.4.1.343.2.19.1.2.10.11Maximum number of CMMs possible in this chassis.
.1.3.6.1.4.1.343.2.19.1.2.10.21The number of CMMs in the system. This is a bit of overkill as the first version doesn't have more than one CMM, but as there is talk of future revisions containing a second, this is designed in to be consistent with the other modules.
.1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.10Asset Tag # of device
.1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.12MAC Address of internal (chassis) Ethernet interface
.1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.5Device Name
.1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.16Firmware version of the EBF
.1.3.6.1.4.1.343.2.19.1.2.10.201.2.1..
.1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.11MAC Address of external (front panel) Ethernet interface
.1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.14State of the Fault LED on the CMM
.1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.1column used to identify a particular CMM.
.1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.8Static maximum power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Maximum power generation/consumption not known or specified
.1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.4Manufacture date/time
.1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.9Static Nominal power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Nominal power generation/consumption not known or specified
.1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.6Device Part Number
.1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.13State of the Power LED on the CMM
.1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.2Flag whether this CMM is present (forward thinking for future products that will contain redundant CMMs)
.1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.15State of the Presence LED on the CMM (and optionally intiate identification)
.1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.7Device Serial Number
.1.3.6.1.4.1.343.2.19.1.2.10.201.2.1.3Device manufacturer
More MIBs from Intel
Browse all IntelMIBs →Standard SNMP MIB module defining data structures for INTELCORPORATIONBASEBOARD-MIB.
Standard SNMP MIB module defining data structures for INTELCORPORATIONBASEBOARDMAPPER-MIB.
Standard SNMP MIB module defining data structures for INTELCORPORATIONBASEBOARD2-MIB.
SNMP MIB module
The INTEL-SERVER-BASEBOARD7 MIB module enables SNMP monitoring and management of Intel server baseboard components, specifically providing read access to hardware sensor data, configurable threshold settings for alerts, and event notifications via the NOTIFICATION-TYPE construct.
SNMP MIB module