Home/Catalog/IMMALERT-MIB

IMMALERT-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for IMMALERT-MIB.

54
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

54 total
Object Name
ibm
OBJECT IDENTIFIER
.1.3.6.1.4.1.2
IMPORTS
Unknown
.1.3.6.1.4.1.2
ibmProd
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6
supportProcessor
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.158
immalertMIB
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.158.5
ibmSpTrapTempCCritical Alert: Temperature threshold exceeded.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.0
ibmSpTrapVoltCCritical Alert: Voltage threshold exceeded.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.1
ibmSpTrapPowerCCritical Alert: Power failure.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.4
ibmSpTrapHdCCritical Alert: Hard disk drive failure.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.5
ibmSpTrapRdpsCCritical Alert: Redundant Power Supply failure.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.9
ibmSpTrapRdpsNNon-Critical Alert: Redundant Power Supply failure.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.10
ibmSpTrapFanCCritical Alert: Single Fan failure.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.11
ibmSpTrapTempNNon-Critical Alert: Temperature threshold exceeded.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.12
ibmSpTrapVoltNNon-Critical Alert: Voltage threshold exceeded.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.13
ibmSpTrapOsToSSystem Alert: OS Timeout value exceeded.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.21
ibmSpTrapAppSSystem Alert: Application Alert. Refer to Message ID for specific condition.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.22
ibmSpTrapPoffSSystem Alert: Power Off.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.23
ibmSpTrapPonSSystem Alert: Power On.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.24
ibmSpTrapBootSSystem Alert: System Boot Failure.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.25
ibmSpTrapLdrToSSystem Alert: OS Loader Timeout.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.26
ibmSpTrapPFASSystem Alert: Predictive Failure Analysis(PFA) information.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.27
ibmSpTrapRLoginSev-Off Alert: Event Remote Login.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.30
ibmSpTrapSysLogSSystem Alert: System Log 75% full.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.35
ibmSpTrapIhcCCritical Alert: Incompatible hardware configuration.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.36
ibmSpTrapNwChangeSSystem Alert: Network change notification.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.37
ibmSpTrapCPUCCritical Alert: CPU Error.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.40
ibmSpTrapMemoryCCritical Alert: Memory Error.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.41
ibmSpTrapCPUNNon-Critical Alert: CPU Error.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.42
ibmSpTrapMemoryNNon-Critical Alert: Memory Error.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.43
ibmSpTrapHardwareCCritical Alert: Other Failure - refer to Message ID for specific condition.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.50
ibmSpTrapHardwareNNon-Critical Alert: Warning - refer to Message ID for specific condition.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.60
ibmSpTrapPowerNNon-Critical Alert: Power.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.164
ibmSpTrapFanNNon-Critical Alert: Fan Error.
TRAP-TYPE
.1.3.6.1.4.1.2.6.158.5.0.165
immtrapg
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.158.5.1
altDateTimeTimestamp of Local Date and Time when alert was generatedro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.158.5.1.1
altSpTxtIdSP System Identification - Text Identificationro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.158.5.1.3
altSysUuidHost System UUID(Universal Unique ID)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.158.5.1.5
altSysSernHost System Serial Numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.158.5.1.6
altPriorityAlert Severity Value - Critical Alert(0) - Non-Critical Alert(2) - System Alert(4) - Recovery(8)ro
INTEGER
.1.3.6.1.4.1.2.6.158.5.1.8
altMsgTextAlert Message Textro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.158.5.1.9
altMsgIDAlert Message IDro
INTEGER
.1.3.6.1.4.1.2.6.158.5.1.10
altMsgIDPrefixAlert Message IDro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.158.5.1.11
altHostContactHost Contactro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.158.5.1.12
altHostLocationHost Locationro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.158.5.1.13
altHostRoomIDHost Location - Room IDro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.158.5.1.14
altHostRackIDHost Location - Rack IDro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.158.5.1.15
altHostLowestUposHost Location - Lowest U-positionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.158.5.1.16
altHostBladeBayHost Location - BladeBayro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.158.5.1.17
altEventIDEvent Identifierro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.158.5.1.18
altServiceableServiceability information.ro
Enumeration
.1.3.6.1.4.1.2.6.158.5.1.19
altTestThis event generated for test purposes.ro
Enumeration
.1.3.6.1.4.1.2.6.158.5.1.20
altFailingFRUsOrdered list of Failing FRU Numbers, separated by commas.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.158.5.1.21
altHostMTMMachine Type and Model for failing host.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.158.5.1.22
altAuxDataAuxiliary data that may be included for some events.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.158.5.1.23
IMMALERT-MIB - SNMP MIB Reference | MIBs Explorer